R4
Miniature plug-in power relays
1
6 A/250 V AC
Contacts
Contact number & arrangement Contact material Voltage Max. switching voltage AC/DC Min. switching voltage Current Rated load
• WT - standard plug-in version with indicating flag and manual testing/latching lever • Miniature size • Cadmium - free contacts • Coil AC and DC • Plug-in version - rail mount TH35, EN 50022 • Plug-in, solder, PCB versions available • General purpose relays 4C/O AgNi; AgNi/Au 0,2 µm; AgNi/Au 5 µm 250 V / 250 V 5V AC1 DC1 6 A / 250 V AC - plug-in version 5 A / 250 V AC - PCB version 6 A / 24 V DC - plug-in version 5 A / 24 V DC - PCB version 5 mA (AgNi, AgNi/Au 0,2 µm) 1 mA (AgNi/Au 5 µm) 12 A 6 A - plug-in version 5 A - PCB version 1 500 VA - plug-in version 1 250 VA - PCB version 0,1 W (AgNi/Au 5 µm); 0,3 W (AgNi, AgNi/Au 0,2 µm) £ 100 mW at 100 mA, 24 V 1 200 cycles/hour 18 000 cycles/hour
Min. switching current Max. inrush current Rated current Max. breaking capacity Min. breaking capacity Resistance Max. operating frequency • at rated load • no load AC1
AC1
Coil
Voltage Rated voltage Must release voltage Operating range of supply voltage Rated power consumption 5...220V DC 6...240 V AC 50 Hz ³ 0,1 Un DC; ³ 0,2 Un AC see Tables 1, 2 0,9 W DC; 1,6 VA AC B250 250 V AC 2 500 V AC 1 500 V AC 2 000 V AC
³ 1,6 mm ³ 3,2 mm
Insulation
Insulation category Voltage Insulation rated voltage Dielectric strength • coil-contact • contact-contact • pole-pole Contact-coil distance • clearance • creepage
General data
Operating time (typical value) Release time (typical value) Electrical life • resistive • cos j Mechanical life (cycles) Dimensions (L x W x H) 10 ms AC; 13 ms DC 8 ms AC; 3 ms DC at 6 A, 250 V AC see Fig. 2 ³ 2 x 10 7 27,5 x 21,2 x 35,6 mm - plug-in standard version (WT) 27,5 x 21,2 x 33 mm - PCB version and version with threaded bolt 35 g -40...+85 °C AC: -40...+55 °C; DC: -40...+70 °C IP 40 10 g (NO); 5 g (NC) 5g for 10...150 Hz max. 270 °C max. 5 s B, cUL, UL, VDE, GOST
³ 10
5
Weight Ambient temperature • storing • operating Cover protection category Shock resistance Vibration resistance Solder bath temperature Soldering time Approvals
2
R4
Coil data - DC version
Rated voltage V DC
5 6 12 24 48 60 80 110 125 220
Miniature plug-in power relays
Table 1
Coil resistance (±10%) at 20 °C W
28 40 160 640 2 600 4 000 7 100 13 600 16 000 54 000
Coil code
1005 1006 1012 1024 1048 1060 1080 1110 1125 1220
Coil operating range V DC min. (at 20 °C)
4,0 4,8 9,6 19,2 38,4 48,0 64,0 88,0 100,0 176,0
max. (at 55 °C)
5,5 6,6 13,2 26,4 52,8 66,0 88,0 121,0 137,5 242,0
Coil data - AC 50 Hz version
Coil operating range V AC
Table 2
min. (at 20 °C)
3006 3012 3024 3042 3048 3060 3080 3110 3120 3127 3220 3230 6 12 24 42 48 60 80 110 120 127 220 230/240 12 50 190 565 785 1 240 2 190 3 880 4 150 4 940 16 300 17 400 4,8 9,6 19,2 33,6 38,4 48,0 64,0 88,0 96,0 101,6 176,0 184,0
max. (at 55 °C)
6,6 13,2 26,4 46,2 52,8 66,0 88,0 121,0 132,0 139,0 242,0 253,0
Electrical life at AC resistive load
Fig. 1
Electrical life reduction factor at AC inductive load
Fig. 2
1 0,8
F
Reduction factor
0,6
0,4
1 0,8
0,6
0,4
Power factor
0,2
cos j
R4
Miniature plug-in power relays
3
4
R4
Mounting
Miniature plug-in power relays
Relays R4 are designed for: • screw terminals sockets GZT4 (modules and clips available) and GZ4 - for DIN rail mounting, • PCB terminals sockets SU4D - for PCB mounting,, • solder terminals sockets SU4L and G4, • direct PCB mounting.
Ordering codes
20 - AgNi 21 AgNi/Au 0,2 µm 23 - AgNi/Au 5 µm
See Tables 1, 2, page 2
14 - 4C/O
*
- -- - LDLD WT WTL WTD WTLD no additional features LED indicator arc suppressing diode LED indicator +arc suppressing diode indicating flag + manual testing/latching lever (standard) indicating flag + manual testing/latching lever + LED indicator indicating flag + manual testing/latching lever + arc suppressing diode indicating flag + manual testing/latching lever + LED indicator + arc suppressing diode
* D, LD, WTD, WTLD - only for DC coils WT - standard features plug-in power relays
2002-12-20