0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
ZMOTIONS200ZRDG

ZMOTIONS200ZRDG

  • 厂商:

    ZILOG(齐洛格)

  • 封装:

    -

  • 描述:

    RE200B, Z8FS021 ZMOTION® Series Motion, Pyroelectric, PIR (Passive Infrared) Sensor Evaluation Board

  • 数据手册
  • 价格&库存
ZMOTIONS200ZRDG 数据手册
PRODUCT FEATURES  INSTALLATION GUIDE    Intrusion Reference Design   SETTING DETECTOR FEATURES  DETECTOR CONNECTIONS  PET IMMUNITYJUMPER (PET) INSTALLING THE DETECTOR  The ZMOTION Intrusion Reference Design (ZIRD) The detector can be wall-, ceiling- or corner-mounted, demonstrates how to use Zilog’s ZMOTION Intrusion depending on the application requirements. It ships with Motion Detection solution in a PIR-based intrusion the WA 1.2 GI 12 V4 lens installed. motion detector. It also shows how to implement 1. Unscrew the holding screw at the bottom of the additional functions such as anti-mask and power supply detector and gently raise the front cover until it supervisory features. detaches from the base. The ZMOTION Intrusion Motion Detection solution 2. Carefully remove the screw securing the PCB and lift provides an integrated and flexible solution for Passive it out of the detector base by grasping the terminal Infrared (PIR)-based security/intrusion motion detection block. applications. It includes the Z8FS021 ZMOTION 3. Break out the required knockout screw holes for Intrusion Detection MCU combined with a selection of proper mounting. lenses and pyroelectric sensors to fit a range of intrusion 4. The rectangular channel in the detector base is used motion detection applications. for wire entry. You may also use mounting holes that are not in use for running the wiring into the detector. Main Features:  Pull the wires through the hole in the base.  Complete Intrusion Motion Detection design 5. Mount the detector base to the wall, corner or ceiling supporting three lens types: and tighten the mounting screws so the detector is o WA 1.2 GI 12 V4 (18 meter, wide angle) – not accidently knocked out of place. Installed 6. Reinstall the PC board by fully tightening the holding o LR 1.2 GI 12 V3 (30 meter, corridor) screw. o VB 1.2 GI V1 (15 meter, vertical barrier)  White light immunity >12,000 LUX 7. Make the required electrical connections to the  12kg/30kg selectable pet immunity detector terminal block (see Detector Connections).  Selectable NORMAL and PULSE modes 8. Select the appropriate jumper settings for the desired  Auto-LED detector features (see Setting Detector Features).  Anti-mask demonstration 9. Replace the cover by inserting it back into the closing  Power supply supervisory pins, then fasten the holding screw. TECHNICAL SPECIFICATIONS  Detection Method Power Input Current Consumption: Standby with Anti-Mask On Standby with Anti-Mask Off Detection Range: WA 1.2 GI 12 V4 LR 1.2 GI 12 V3 VB 1.2 GI V1 Walk Test/Auto-LED Time Alarm O/P Active Time Alarm O/P Type Trouble O/P Type Tamper O/P Type Power on Warm up Time White Light Immunity Pet Immunity All electrical connections are made via the Terminal Block located at the top of the PCB. Install the wire by inserting it into the terminal block and using a flathead or Phillips screwdriver to secure it in place. Install PET Jumper J2 to select 30KG pet immunity. Remove PET Jumper J2 to select 12KG (Normal) pet immunity. PULSE JUMPER (PULSE) Install PULSE Jumper J1 to select 2-PULSE mode. Remove PULSE Jumper J1 to select 1-PULSE (NORMAL) mode. LED JUMPER (AUTO-LED) ANTI-MASK JUMPER Install ANTI-MASK Jumper J4 to enable Anti-Mask detection. The Yellow Trouble LED will illuminate and the Trouble output contact will be activated when a masked condition is detected. Remove ANTI-MASK Jumper J4 to disable Anti-Mask detection.  Connection Tamper Trouble N.O. COM N.C. +/– 12V 16mA 19mA 18 meters 30 meters 15 meters 5 minutes 2 seconds Form-A/Form-B Form-A Form-B 45 seconds >12,000 LUX Selectable 12KG/30KG Power Supply Supervisory Trip 8.5V Level Dimensions (LxWxH) 6.4cm x 5.1cm x 12.7cm   Remove Jumper J3 (LED) to enable LED indication (LED ON). The Red status LED will illuminate when motion is detected. Install Jumper J3 to disable Red Status LED indication (LED AUTO). The status LED does not illuminate when motion is detected. In this position, the status LED can be enabled by shining a bright light (e.g., a flashlight) onto the status LED (within ≈6 inches) for 2 seconds. This mode will stay active for 5 minutes. Dual Element PIR 8.5V to 18V Description Tamper switch – normally closed Trouble contacts – normally open Alarm contact – normally open Common alarm terminal for N.O. and N.C. Alarm contact – normally closed Detector DC supply voltage       DETECTION PATTERNS  DETECTION PATTERN: LR 1.2 GI 12 V3  DETECTION PATTERN: VB 1.2 GI V1  Figure 1. Wide Angle Lens (Installed) Figure 2. Long Range Lens Figure 3. Vertical Barrier Lens     QS008202-0711 Copyright ©2011 Zilog Inc. All rights reserved. www.zilog.com Zilog’s ZMOTION™ Intrusion Detection Solution A Superior Motion Detection Solution for Security-Related Applications This reference design demonstrates how to use Zilog’s ZMOTION Intrusion Motion Detection solution in a PIRbased intrusion motion detector. It also shows how to implement additional functions such as anti-mask and power supply supervisory features. The ZMOTION Intrusion Motion Detection (ZIRD) provides an integrated and flexible solution for Passive Infrared (PIR)-based security/intrusion motion detection applications. It includes the Z8FS021 ZMOTION Intrusion Detection MCU combined with a selection of lenses to fit a range of intrusion motion detection applications. The Z8FS021 ZMOTION Intrusion MCU ships preprogrammed with motion detection software algorithms that comprise the ZMOTION Engine. These software algorithms run in the background while control and status of the Engine is accessed through a software Application Programmer Interface (API). Optimized API settings are provided that match the Engine operation to each of the lens and pyroelectric sensor combinations provided. Status & Trouble LED (White Light Immunity) WA 1.2 GI 12 V4 Fresnel Lens Anti‐Mask (Active IR) Part Number Reference ZMOTION Intrusion Reference Design (ZMOTIONS200ZRDG) Reference Documents To download any of the following documents and source code, please visit the Zilog website at: www.zilog.com/zmotion. ZMOTION Intrusion Reference Design Document (RD0001) ZMOTION Intrusion Reference Design Source Code (RD0001-SC01) ZMOTION Intrusion Detection Product Specification (PS0288) Z8 Encore! XP F082A Series Product Specification (PS0228) ZMOTION Lens and Pyroelectric Sensor Product Specification (PS0286) ZMOTION: A New PIR Motion Detection Architecture (WP0017) ZMOTION Detection Lens and Pyro Sensor Configuration Guide (WP0018) ZMOTION Intrusion Reference Design Lab Findings Report (WP0019) QS008202-0711 Copyright ©2011 Zilog Inc. All rights reserved. www.zilog.com
ZMOTIONS200ZRDG 价格&库存

很抱歉,暂时无法提供与“ZMOTIONS200ZRDG”相匹配的价格&库存,您可以联系我们找货

免费人工找货