UE10-3OS3D0

UE10-3OS3D0

  • 厂商:

    SICK

  • 封装:

    Module

  • 描述:

    RELAY SAFETY 5PST 6A 24V

  • 数据手册
  • 价格&库存
UE10-3OS3D0 数据手册
Product data sheet UE10-3OS3D0 UE10-3OS SAFETY RELAYS UE10-3OS3D0 | UE10-3OS SAFETY RELAYS A B C D E F Ordering information Type Part no. UE10-3OS3D0 6024918 Other models and accessories www.sick.com/UE10-3OS Illustration may differ Detailed technical data H I J K L M N O P Q R S T Safety-related parameters Safety integrity level SIL3 (IEC 61508) 1) 1) Category Category 4 (EN ISO 13849) 1) Performance level PL e (EN ISO 13849) 1) B10d parameter 1.26 x 106 switching cycles (AC-15, 230 V, I = 1.5 A) 5.9 x 106 switching cycles (AC-15, 230 V, I = 0.75 A) 4.35 x 105 switching cycles (DC-13, 24 V, I = 2.5 A) 1 x 107 switching cycles (DC-13, 24 V, I = 0.63 A) PFHD (mean probability of a dangerous failure per hour) 3.0 x 10-8 (EN ISO 13849) TM (mission time) 20 years (EN ISO 13849) 1)  If the feedback current path Y1 - Y2 (external device monitoring) is monitored using an appropriate main unit. Electrical data Operating data Voltage supply B1-B2/B3-B4 Output circuit > 25 V AC / 60 V DC PELV Output circuit ≤ 25 V AC / 60 V DC PELV or SELV Power consumption 2.4 W (DC) Overvoltage category III (see operating instructions) Rated insulation voltage Ui 300 V AC Rated impulse withstand voltage Uimp 4 kV Test voltage 2 kV (50 Hz) (EN 60439-1) Input circuits: B1-B2/B3-B4 Input voltage 24 V DC (15 V DC ... 30 V DC) Input current ≤ 500 mA 2 SAFETY RELAYS | SICK Product data sheet | 2023-07-15 01:49:43 Subject to change without notice UE10-3OS3D0 | UE10-3OS SAFETY RELAYS Output current paths: 13/14, 23/24, 33/34, 41/42, Y1/Y2 Response time (≤ 20 ms) 1) Number of enabling current paths (N/O) 3, relevant for safety Number of signaling current paths (normally 1, not safety-relevant closed) Number of feedback current paths (normally 1, external device monitoring (EDM) closed) Contact type Positively driven Contact material Silver alloy, gold flashed Switching voltage Enabling current path 10 V AC ... 230 V AC 10 V DC ... 300 V DC Signaling current path 10 V AC ... 230 V AC 10 V DC ... 300 V DC Feedback current path 10 V DC ... 24 V DC Current-carrying capacity per OSSD Enabling current path 5 mA ... 6 A Signaling current path 5 mA ... 6 A Feedback current path 5 mA ... 100 mA Total current ≤ 12 A Usage category AC-15/DC-13 (EN 60947-5-1) Rated operating current (voltage) 4 A (230 V AC) 360 switching cycles/h 3 A (230 V AC) 3600 switching cycles/h 4 A (24 V DC) 360 switching cycles/h 2.5 A (24 V DC) 3600 switching cycles/h Mechanical life (relay contacts) 1 x 107 switching cycles Electrical life (relay contacts) 2 x 106 switching cycles 1)  K1/K2. Mechanical data Dimensions (W x H x D) 22.5 mm x 114 mm x 96.5 mm Contamination rating 3 (EN 50178) Weight 0.2 kg Classifications eCl@ss 5.0 27371990 eCl@ss 5.1.4 27371990 eCl@ss 6.0 27371819 eCl@ss 6.2 27371819 eCl@ss 7.0 27371819 eCl@ss 8.0 27371819 eCl@ss 8.1 27371819 eCl@ss 9.0 27371819 eCl@ss 10.0 27371819 eCl@ss 11.0 27371819 eCl@ss 12.0 27371819 2023-07-15 01:49:43 | Product data sheet  Subject to change without notice SAFETY RELAYS | SICK 3 UE10-3OS3D0 | UE10-3OS SAFETY RELAYS EC001449 ETIM 6.0 EC001449 ETIM 7.0 EC001449 ETIM 8.0 EC001449 UNSPSC 16.0901 41113704 Dimensional drawing (Dimensions in mm (inch)) 78 (3.07) 58 114 93.7 (3.69) (4.49) (2.28) (4.24) 93.3 (3.67) 96.5 22.5 (3.8) (0.89) H I J K L M N O P Q R S T ETIM 5.0 107.6 A B C D E F 67 (2.64) 85 (3.35) 4 SAFETY RELAYS | SICK Product data sheet | 2023-07-15 01:49:43 Subject to change without notice UE10-3OS3D0 | UE10-3OS SAFETY RELAYS Connection diagram 13 23 B1 33 B2 CH 1 B3 Y2 B3 Y1 41 13 23 33 Y2 42 14 24 34 K 2 B4 24 Y1 K 1 CH 2 14 B1 34 2023-07-15 01:49:43 | Product data sheet  Subject to change without notice B2 41 42 B4 SAFETY RELAYS | SICK 5 Online data sheet SICK at a glance SICK is one of the leading manufacturers of intelligent sensors and sensor solutions for industrial applications. A unique range of products and services creates the perfect basis for controlling processes securely and efficiently, protecting individuals from accidents and preventing damage to the environment. We have extensive experience in a wide range of industries and understand their processes and requirements. With intelligent sensors, we can deliver exactly what our customers need. In application centers in Europe, Asia and North America, system solutions are tested and optimized in accordance with customer specifications. All this makes us a reliable supplier and development partner. Comprehensive services complete our offering: SICK LifeTime Services provide support throughout the machine life cycle and ensure safety and productivity. For us, that is “Sensor Intelligence.” Worldwide presence: Contacts and other locations – www.sick.com SICK AG | Waldkirch | Germany | www.sick.com
UE10-3OS3D0 价格&库存

很抱歉,暂时无法提供与“UE10-3OS3D0”相匹配的价格&库存,您可以联系我们找货

免费人工找货