RP1A23D5

RP1A23D5

  • 厂商:

    CARLOGAVAZZI

  • 封装:

    SIP-4

  • 描述:

    固态 SPST-NO(1 Form A) 4-SIP

  • 数据手册
  • 价格&库存
RP1A23D5 数据手册
 RP1A, RP1B 1-phase PCB mount solid state relays Main features • • • • • • • • • • AC Solid State Relay for PCB mounting Zero switching or instant-on Rated operational current: 3, 5 or 5.5 AACrms Rated operational voltage: Up to 480 VACrms Surface mount technology Flexible encapsulation for extended life Control voltage: 3 to 32 VDC / 16 to 32 VAC Opto-isolation: > 4000 VACrms Blocking voltage: Up to 1000 Vp Non-repetitive surge current: Up to 250 Ap Description The RP1 is an SSR series for socket- or PCBmounting, providing an ideal interface between logic controls and AC loads. The RP1 is designed for resistive and inductive loads up to 480 VACrms. Internally this new series enjoys an improved technical design with the introduction of stress-free flexible encapsulation and automated assembly of components. The Solid State technology used can withstand peak voltages of 1000 V, making the RP1 series suitable to drive AC loads such as valve solenoids and small induction motors. Applications These relays can be used to switch heaters, motors, lights, valves or solenoids. Main functions • Zero cross or Instant on AC switching • Ratings up to 480 VACrms, 5.5 AACrms • 3-32 VDC or 16-32 VAC control voltage 04/12/2019 RP1A, RP1B DS ENG Carlo Gavazzi LTD 1 RP1A, RP1B  References Order code RP1 Enter the code entering the corresponding option instead of Code R P 1 Option A B 23 40 48 Description Notes Solid State Relay (PCB) Number of poles Switching mode: zero switching Switching mode: instant-On switching Rated operational voltage: 230 VACrms Rated operational voltage: 400 VACrms Rated operational voltage: 480 VACrms D Control voltage: 3 to 32 VDC A 3 5 6 Control voltage: 16 to 32 VAC Rated operational current: 3 AACrms Rated operational current: 5 AACrms Rated operational current: 5.5 AACrms M1 = Mounting on DIN EN adaptor RPM1 M2 = Mounting on DIN EN adaptor RPM2 Mx 4 to 32 VDC for RP1A48.. 4 to 32 VDC for RP1B40.. and RP1B48.. Only available for 230V, 5.5 A Max. 250V Max. 600V Selection guide Rated operational voltage Blocking voltage 230 VACrms 650 Vp 400 VACrms 850 Vp 480 VACrms 1000 Vp Control voltage 3 to 32 VDC 16 to 32 VAC 3 to 32 VDC 4 to 32 VDC 4 to 32 VDC 3 AACrms RP1A23D3 RP1B23D3 RP1A40D3 RP1B40D3 RP1A48D3 RP1B48D3 Rated operational current 5 AACrms 5.5 AACrms RP1A23D5 RP1A23D6 RP1B23D5 RP1B23D6 RP1A23A6 RP1A40D5 RP1A40D6 RP1B40D5 RP1B40D6 RP1A48D5 RP1A48D6 RP1B48D5 RP1B48D6 Selection Guide (mounted on DIN EN adaptor) Rated operational voltage Blocking voltage 230 VACrms 650 Vp 480 VACrms 1000 Vp Control voltage 5 to 34 VDC 16 to 32 VAC 6 to 34 VDC Rated operational current 3 AACrms 5 AACrms 5.5 AACrms RP1A23D3M1 RP1A23D5M1 RP1A23D6M1 RP1B23D3M1 RP1B23D5M1 RP1B23D6M1 RP1A23A6M1* - RP1A48D5M2 - * Version RP1A23A6M1 does not include an LED on the DIN adaptor. 04/12/2019 RP1A, RP1B DS ENG Carlo Gavazzi LTD 2 RP1A, RP1B  CARLO GAVAZZI compatible components Purpose DIN adaptors Component name/code RPM1* RPM1V* RPM1P RPM1PD* RPM2 Notes DIN adaptor 250V with LED DIN adaptor 250V with LED + varistor DIN adaptor 250V with pins for removal of RP DIN adaptor 250V with pins for removal of RP + LED DIN adaptor 600V with LED *not suitable for use with RP1A23A6 Further reading Information - 04/12/2019 RP1A, RP1B DS ENG Where to find it - Carlo Gavazzi LTD 3 RP1A, RP1B  Features General Material Potting compound Weight Isolation: input to output Insulation resistance Insulation capacitance PBT, RAL7035 Flame-retardant flexible silicone rubber Approx. 20 g 4 kVACrms 1010 8 pF Dimensions 04/12/2019 RP1A, RP1B DS ENG Carlo Gavazzi LTD 4 RP1A, RP1B  Performance Mains supply Operational voltage range RP1A RP1B Operational frequency range Blocking voltage Zero voltage turn-on RP1.23 RP1.40 RP1.48 12 - 265 VACrms 12 - 265 VACrms 20 - 440 VACrms 12 - 440 VACrms 45 - 65 Hz 850 Vp < 10 V 20 - 530 VACrms 12 - 530 VACrms RP1....3 RP1....5 RP1....6 3A 2A 5A 3A 20 mA > 0.5 12 AACrms 80 Ap < 1 mA 50 A2s 5.5 A 5A 650 Vp 1000 Vp Outputs Rated operational current AC 51 @ Ta = 25°C AC 53a @ Ta = 25°C Min. operational load current Power factor Rep. overload current t=1 s Non-rep. surge current t=20 ms Off-state leakage current I2t for fusing t=10 ms Critical dV/dt off state min. On-state voltage drop @ rated current 10 AACrms 65 Ap 20 A2s 250 V/μs 16 AACrms 250 Ap 500 V/μs 340 A2s < 1.2 Vrms Inputs Control voltage RP1.23.. RP1A40.. RP1B40.. RP1.48.. Pick-up voltage RP1.23.. RP1A40.. RP1B40.. RP1.48.. Drop-out voltage Max. input curent RP1A... RP1B... Max. reverse voltage Response time pick-up RP1A... RP1B... Response time drop-out RP1A... RP1B... 04/12/2019 RP1A, RP1B DS ENG RP1..D RP1..D..Mx 3-32 VDC 4-32 VDC 5-34 VDC 6-34 VDC 2.8 VDC 3.8 VDC 4.8 VDC 5.8 VDC 1.2 VDC 10 mADC 15 mADC 32 VDC 34 VDC < 10 ms < 160 μs (12 VDC/ 50 Hz) < 320 μs (5 VDC/ 50 Hz) < 10 ms < 10 ms RP1A23A6 16 - 32 VAC 10 VAC 5 VAC 13 mAAC < 20 ms < 20 ms - Carlo Gavazzi LTD 5 RP1A, RP1B  Derating curve Load current (AACrms) 6 5 4 3 D6 D5 2 D3 1 0 20 30 40 50 60 70 Surrounding temp. (°C) Derating curve is used for finding max. load current at an elevated ambient temperature. The 3 lines in the graph represent the 3 nominal current ratings of the RP1 series (RP1...D3/D5/D6). When used at full load current, the relays must be placed vertically. If more than one relay is mounted, please allow a minimum distance of 20 mm in between for sufficient air cooling. Increased Current Options Ipeak Inom Tamb = 25oC I peak (Amps) D5 : t (minutes) D6 : t (minutes t 6 15 15 8 5 5 10 3 3 Note: even though the D3 can withstand a slight increase in current for a limited time, it is not recommended for this purpose. 04/12/2019 RP1A, RP1B DS ENG Carlo Gavazzi LTD 6 RP1A, RP1B  Compatibility and conformity Standards compliance LVD: EN 60947-4-3 EMCD: EN 61000-6-2, EN 61000-6-4 UL508 C22.2 No. 14-13 VDE 0700, VDE 0805 (excluding RP1A23A6) Approvals Electromagnetic compatibility (EMC) - immunity EN/IEC 61000-4-2 Electrostatic discharge (ESD) 8 kV air discharge, 4 kV contact (PC1) EN/IEC 61000-4-3 10 V/m, from 80 MHz to 1 GHz (PC1) Radiated radio frequency 10 V/m, from 1.4 to 2 GHz (PC1) 10 V/m, from 2 to 2.7 GHz (PC1) EN/IEC 61000-4-4 Electrical fast transient (burst) Output: 2 kV, 5 kHz (PC2) Input: 1 kV, 5 kHz (PC2) EN/IEC 61000-4-6 Conducted radio frequency 10V/m, from 0.15 to 80 MHz (PC1) EN/IEC 61000-4-5 Output, line to line: 1 kV (PC2) Electrical surge Output, line to earth: 1 kV (PC2)1 Input, line to line: 500 V (PC2)2 Input, line to earth: 500 V (PC2)2 EN/IEC 61000-4-11 0% for 0.5, 1 cycle (PC2) Voltage dips 40% for 10 cycles (PC2) 70% for 25 cycles (PC2) EN/IEC 61000-4-11 Voltage Interruptions 0% for 5000ms (PC2) Electromagnetic compatibility (EMC) - emissions Radio interference field emisEN/IEC 55011 sion (radiated) Class A: from 30 to 1000 MHz From 0.15 to 30 MHz EN/IEC 55011 Radio interference voltage Class A (industrial) with filter capacitor across the Mains supply emissions (conducted) EN/IEC 60947-4-3 Class A (no filtering needed) Note: • Performance Criteria 1 (PC1): no degradation of performance or loss of function is allowed when the product is operated as intended. • Performance Criteria 2 (PC2): during the test, degradation of performance or partial loss of function is allowed. However when the test is complete the product should return operating as intended by itself. • Performance Criteria 3 (PC3): temporary loss of function is allowed, provided the function can be restored by manual operation of the controls. • Control input lines must be installed together to maintain products' susceptability to Radio Frequency interference. • 1 A suppression device, such as a varistor, needs to be connected across the output terminals L1, T1 for immunity against higher voltage levels. • 2 A suppression device, such as a transil, needs to be connected across the control terminals A1, A2 for immunity against higher voltage levels. 04/12/2019 RP1A, RP1B DS ENG Carlo Gavazzi LTD 7 RP1A, RP1B  Environmental specifications Operating temperature -20° to +70°C (-4° to +158°F) Storage temperature -40° to +100°C (-40° to +212°F) Pollution degree 2 EU RoHS compliant Yes 25 China RoHS The declaration in this section is prepared in compliance with People’s Republic of China Electronic Industry Standard SJ/ T11364-2014: Marking for the Restricted Use of Hazardous Substances in Electronic and Electrical Products. Toxic or Harardous Substances and Elements Part Name Lead (Pb) Mercury (Hg) Cadmium (Cd) Hexavalent Chromium (Cr(Vl)) Polybrominated biphenyls (PBB) Polybrominated diphenyl ethers (PBDE) Power Unit Assembly x O O O O O O: Indicates that said hazardous substance contained in homogeneous materials fot this part are below the limit requirement of GB/T 26572. X: Indicates that said hazardous substance contained in one of the homogeneous materials used for this part is above the limit requirement of GB/T 26572. 这份申明根据中华人民共和国电子工业标准 SJ/T11364-2014:标注在电子电气产品中限定使用的有害物质 有毒或有害物质与元素 零件名称 铅 (Pb) 汞 (Hg) 镉 (Cd) 六价铬 (Cr(Vl)) 多溴化联苯 (PBB) 多溴联苯醚 (PBDE) 功率单元 x O O O O O O:此零件所有材料中含有的该有害物低于GB/T 26572的限定。 X: 此零件某种材料中含有的该有害物高于GB/T 26572的限定。 04/12/2019 RP1A, RP1B DS ENG Carlo Gavazzi LTD 8 RP1A, RP1B  RP1... Functional diagram (+) 3 1 REGULATION ZC Control input * IO 2 (-) 4 ZC - Zero Crossing IO - Instant On RP..Mx Functional diagram RP..Mx RP1... (+) 3 Control input (-) 4 (+) 3 Control input (-) 4 3 (+) (+) 3 REGULATION 4 (-) Control input 11 1 REGULATION ZC IO ZC IO 2 (-) 4 ZC - Zero Crossing IO - Instant On * * 22 ZC - Zero Crossing IO - Instant On * The varistor is not included in the solid state relay. Connecting a varistor across terminals 1-2 helps protect the solid state relay against damages by over-voltage Connection specifications Terminals Terminals soldering temperature Copper alloy, tin-plated max. 300°C for 5 seconds COPYRIGHT ©2019 Content subject to change. Download the PDF: www.productselection.net 04/12/2019 RP1A, RP1B DS ENG Carlo Gavazzi LTD 9
RP1A23D5 价格&库存

很抱歉,暂时无法提供与“RP1A23D5”相匹配的价格&库存,您可以联系我们找货

免费人工找货