CCIC BGA heat sinks
-
Aluminium BGA and compact crosscut heat sinking for a variety of
applications requiring simple extension of surface area for cooling.
Typically used with DSP, FPGAs, and other electronics packages.
Double sided adhesive provides simple and effective attachment
Technical specifications:
10
Thermal
resistance
(sink to
ambient) K
/ W at 0.3
m/s
7.93
Thermal
resistance
(sink to
ambient)
K / W at
1.0 m/s
3.57
9
9.51
5.29
9
9.96
5.87
CCI10
38
6
9.12
4.65
00C845401A
25
10
9.6
5.3
CCI11
40
5
9.38
5.14
Width
&
Length
Height
CCI02
45
CCI08
28
CCI09
30
Part Number
CCI Heat Pipes
-
-
Copper heat pipes, pure water filled for operation between +5 degC and 110
degC.
Various wick structures offered, Screen mesh, Grooved, Sintered and
composite (G+S)
Low thermal resistance for transportation of heat from hot source to
exchanger. Heat pipe can be incorporate into a block and fix a finned
structure (or heat sink) to allow effective heat removal.
Thermal resistance of pipe taken at 70degC working temperature (adiabatic),
under horizontal orientation, evaporator section 15mm, and condensation
section 60mm
Structure
Length
Original
Diameter
Thickness
00C93390101
Sintered
100
5
5
Thermal
resistance of
pipe Rpipe
in
(K / W)
0.02 – 0.04
00C93400101
Sintered
150
6
6
0.02 – 0.03
65
00C93410101
SM
150
4
2
0.65 – 0.90
15
30
Part Number
Operating
Max
Power
(W)
40
00C93420101
SM
200
6
2
0.35 – 0.60
00C93430101
Groove
100
5
2.5
0.03 – 0.06
30
00C93440101
Groove
150
6
6
0.02 – 0.03
65
00C93450101
Groove
150
8
2.5
0.003 – 0.05
15
00C93460101
G+S
200
6
3.0
0.003 – 0.008
40
00C93470101
G+S
150
8
4.5
0.003 – 0.015
70
00C93480101
G+S
300
8
8
0.002 – 0.007
65
Design Guidelines
(1) Groove heatpipe
condenser
heatpipe
condenser
evaporator
- 90 deg
0 deg
evaporator
Heat source
•
The heatpipe performance is without change from -90 deg to 0 deg. Larger than 0 deg (i.e. evaporator is
higher than condenser), the performance of grooved pipe will degrade 50%.
(2) Mesh heatpipe
condenser
evaporator
heatpipe
30 deg
- 90 deg
condenser
evaporator
Heat source
• Larger than 30 deg, the performance of mesh pipe will degrade 50%.
(3) Sintered Powder heatpipe
• The orientation has no impact on the sintered powder heatpipe performance.