0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
80PJ-1

80PJ-1

  • 厂商:

    FLUKE(福禄克)

  • 封装:

  • 描述:

    仪器仪表配件

  • 数据手册
  • 价格&库存
80PJ-1 数据手册
Test Tools Catalog Volume one, 2007 Fluke Ti20 Thermal Imager Fluke 975 AirMeter™ Fluke 1587 Insulation Multimeter Find it. Fix it. Fast. Fluke 199C Color ScopeMeter® Test Tools Catalog Volume 37, 2007 Contents Fluke tools for: Commercial Electricians....................................... 3 Industrial Electricians........................................... 4 HVAC/IAQ Technicians......................................... 5 Online resource centers................................... 6 Fluke test tool information.............................. 7 Safety and its importance................................ 8 Service, repair, and calibration..................... 9 Digital Multimeters Multimeter Selection Guide............................... 10 Faster, Safer Multimeters................................... 11 189 Logging Multimeter..................................... 12 FlukeView Forms® Software............................. 13 87V Industrial Multimeter.................................. 14 179 Digital Multimeter........................................ 15 Family of True-rms Digital Multimeters........... 16 117 and 115 True-rms Digital Multimeters.......17 116 and 114 True-rms Digital Multimeters...... 18 77-IV and 73-III Digital Multimeters................ 19 27 Waterproof Multimeter................................. 19 88V Automotive Multimeter..............................20 8845A/8846A 6.5 Digit Precision Multimeters.......................................................... 21 Electrical Testers T3 and T5 Electrical Testers, VoltAlert™..........22 9040 Rotary Field Indicator..............................22 Earth Ground Testers 1625 and 1623 Geo Earth Ground Testers......23 1630 Earth Ground Clamp Meter, Handy Geo Earth Ground Tester.......................24 Power Quality Analyzers 430 Series Power Quality Analyzers................25 43B Power Quality Analyzer.............................26 1760 Power Quality Recorder, 1650 RPM Power Recorder................................................... 27 1740 Series Three-Phase PQ Loggers, VR101S Voltage Event Recorder System.........28 1735 Three-Phase Power Logger, Norma 4/5000 Power Analyzers......................29 Clamp Meters Fluke 345 and LH1050, LH1060 Power Clamp Meters..........................................30 Fluke 360 and LH41 Current Clamp Meters, LH2015 True-rms Clamp Meter......................... 31 Better Clamp Meters from Fluke.......................32 330 and 320 Series Clamp Meters...................33 902 True-rms HVAC Clamp Meter....................54 Insulation Testers and MegOhmMeters 1550B and 1520 Megohmmeters.....................34 1587 and 1577 Insulation Multimeters............35 1507 and 1503 Insulation Testers....................36 Process Calibration Tools Process Tools Selection Guide........................... 37 744, 743B, 741B Documenting Process Calibrators............................................................38 726, 725 Precision Multifunction Process Calibrators............................................................39 724, 714, 712 Temperature Calibrators............40 718, 717 Pressure Calibrator, 700 Series Pressure Modules................................................ 41 715, 707, 705 Loop Calibrators.........................42 789, 787 Process Meters....................................43 771 Milliamp Process Clamp Meter..................44 9102S, 9100S Handheld Drywell Temperature Calibrators....................................44 Intrinsically Safe Products 707Ex, 718Ex, 725Ex, 700PEx, 574-NI, 68IS, 87V Ex........................................................45 Thermal Imagers Ti40/Ti50 Series IR FlexCam® Thermal Imagers...........................................46-47 Ti20 Thermal Imager..........................................48 Ti30™ Thermal Imager.......................................49 TiR4, TiR3, TiR2 IR FlexCam™ Thermal Imagers and IR InSight XS, XST Thermal Imagers.........................................50 Thermometers 570 Series Infrared Thermometers................... 51 54 Series II Contact Thermometers..................52 561 HVACPro Thermometer...............................52 60 Series Infrared Thermometers.....................53 United States General product and sales information: 1-888-44-FLUKE Fluke Thermal Imagers: 1-800-760-4620 (U.S. only) all other regions 1-425-446-4620 Service and calibration: 1-800-993-5853 Parts: 1-800-526-4731 Canada General product and sales information: 1-800-36-FLUKE Service, parts and calibration: 1-800-36-FLUKE canada@fluke.com Australia General product and sales information: (2) 8850-3333 Parts: (2) 8850-3333 Service and calibration: (2) 9771-9300 Singapore General product and sales information: 6738-5655 info.asean@fluke.com Service, parts and calibration: 6737-2922 service.asean@fluke.com Japan General product and sales information: +81-3-3434-0180 Service, parts and calibration: +81-3-3434-0188 Other countries: 1+(425) 446-5500 HVAC/Indoor Air Quality Tools 975 AirMeter,™ 902 True-rms HVAC Clamp Meter.............................................54 971 Temperature Humidity Meter, 983 Particle Counter...........................................55 ScopeMeter® Test Tools ScopeMeter Test Tools Selection Guide...........56 124 Industrial ScopeMeter Test Tools.............. 57 190 Series Color ScopeMeter Test Tools..........58 Fluke ScopeMeter Accessories..........................59 Accessories Accessory Selection Guide.................................60 Accessory Sets and Kits..................................... 61 SureGrip™ Accessories........................................62 Accessories for Electronic and Automotive Applications and High Voltage Probes.............63 Lights, Software and Specialty Accessories................................................... 64-65 Current Clamps..............................................66-67 Temperature Accessories............................ 68-69 Cases, Holsters and Fuses............................ 70-71 What’s new from Fluke.....................back cover  Contact us: Application segment key To help you better identify the right product for your job, you will find the applicable icons located on the outside edge of each product page. Fluke test tools to help you get the job done Fluke tools for commercial electricians Legend Power Distribution Center Heat Exchanger HVAC Blower Drive Control Motor and Motor Control Center Electrical • • • •• • ••• •• • Fluke 1AC II VoltAlert Voltage Detector Fluke 116 Digital Multimeter Fluke 62 Mini IR Thermometer Best suited for: • Non-contact voltage detection on electrical circuits • Detecting voltage before work begins Best suited for: • Measures volts, ohms, capacitance and temperature • Resistance and continuity • 600 V ac and dc measurement range Best suited for: • Surface temperature readings • Finding heating and ventilation problems • Non-contact monitoring of electrical motors and panels See page 22 for details See page 18 for details See page 53 for details Fluke T5 Voltage, Continuity and Current Tester Fluke 322 Clamp Meter Fluke 87V Industrial True-rms Multimeter w/temp Best suited for: • Measure loads on a branch circuit at a service level • Measure the load side voltage of a circuit breaker or fuse • Map outlets to breakers • Check individual voltages (either ac or dc) • Determine resistances up to 1000 ohms • Check circuit continuity Best suited for: • Verify the presence of load current, ac/dc voltage and continuity • Current measurements up to 400 A in tight cable compartments • Higher resolution for loads below 40 A Best suited for: • VSD motor drive installation and troubleshooting • Accurate frequency and voltage measurements on motor drives and in electrically noisy environments • Built-in thermometer for temperature measurements • CAT III 1000 V rated to protect against high voltage transients up to 8 kV See page 22 for details See page 33 for details See page 14 for details  Fluke test tools to help you get the job done Fluke tools for industrial electricians Legend Pumps Drive Control Blowers Motors ••• ••• •• • •• • Front line troubleshooting tools Fluke 87V Industrial True-rms Multimeter w/temp Fluke 1587 Insulation Multimeters Fluke 337 AC/DC True-rms Clamp Meter Best suited for: VSD motor drive installation and troubleshooting. Best suited for: Work on motors, generators, cables or switch-gear. Features: • Accurate frequency and voltage measurements on motor drives and in electrically noisy environments • Built-in thermometer for temperature measurements Features: • Measuring insulation test voltages to 1000 V • Prevents insulation test if voltage > 30 V is detected for added user protection • Filter for motor drive measurements Best suited for: Measure inrush current on electric motor startup and electric motor testing and troubleshooting See page 13 for details See page 35 for details Features: • Inrush current measurements to measure start up current on electric motors • Frequency measurements to help track down power quality problems See page 33 for details Preventive and predictive maintenance Fluke 434 Three-Phase PQ Analyzer Fluke 576 Photographic IR Thermometer Fluke Ti20 Thermal Imager Best suited for: Troubleshooting and preventing problems in power distribution systems. Best suited for: Measuring surface temperatures, quickly locating lubrication problems, overloads, short-circuits or misaligned and overheated equipment. Best suited for: Displaying a visual image of surface temperatures to easily and safely identify potential problems. Features: • Simultaneously measure voltage and current on all three phases and neutral • High-resolution color screen simplifies operation • Tough enough for industrial environments, easy to carry, works for seven hours per battery charge See page 25 for details  Features: • Last ten temperature readings displayed on bar graph for easy reference • Customizable log names, alarms and emissivity values for more efficient, less error-prone predictive maintenance routes See page 51 for details For use on: • Electrical power distribution systems • Electro-mechanical equipment • Process instrumentation • Facility maintenance See page 48 for details Fluke test tools to help you get the job done Fluke tools for HVAC/IAQ technicians Legend Indoor Air Comfort Superheat and Subcooling Electrical Motors/Pumps/Compressors Building Diagnostics Filtration and Ventilation Furnace 00 0124 Fluke 975 AirMeter™ Fluke 983 Particle Counter Fluke 116 Digital Multimeter Best suited for: Optimizing HVAC ventilation settings for ASHRAE 62 recommendations • Simultaneously measures, logs and displays temperature, humidity, velocity, CO2 and CO Best suited for: Troubleshooting and maintaining indoor air quality • Measures particle size, temperature, and relative humidity • Data logging and sixchannel particle size display Best suited for: Troubleshooting HVAC equipment and flame sensors • Thermometer and microamps • Volts ac/dc, resistance, diode, continuity, and Min/Max/Avg See page 54 for details See page 55 for details See page 18 for details Fluke 902 True-rms HVAC Clamp Meter Fluke 561 HVACPro IR Thermometer Fluke IR Insight XS/XST Thermal Imagers Best suited for: HVAC system diagnosis and repair • Capacitance and true-rms • DC current to 200 µA • Contact temperature Best suited for: Measuring hot, moving, electrical energized objects • Contact and non-contact measurement • Compatible with standard type-K thermocouple • Includes Velcro® pipe probe Best suited for: Quick, accurate building diagnostic surveys • High resolution images and display • Industry -leading thermal sensitivity • Simple, one-button operation See page 54 for details See page 52 for details See page 50 for details  Online resource centers Test tool applications Electrical Resource Center HVAC/IAQ Resource Center Plant Maintenance Resource Center Thermal Imaging Resource Center www.fluke.com/electrical_resource_ctr Product demos, software downloads, earth ground education, application notes, training and events information. www.fluke.com/plant_resource_ctr ROI calculator, PDM program, maintenance techniques, tool profiles, common culprits. www.fluke.com/IAQ FAQs, white papers, case studies and application notes, downloads, and product demos. www.fluke.com/thermal_resource Online product selection guide, product information, application notes, software Building Diagnostics Resource Center Biomedical Resource Center www.fluke.com/biomed_resource_ctr Product news and information, catalog, trade-up program, and tradeshow schedule. Electronics Resource Center www.fluke.com/electronics_resource_ctr Tips from the field, product demos, application notes, and product showcase. Intrinsic Safety Resource Center www.fluke.com/ex Standards explanations, industry applications, guidelines, and product information.  Online Resource Centers www.fluke.com/buildings Image gallery, application notes, and expert tips on using thermography to identify structural, thermal, moisture, and air leakage problems in buildings. Precision Measurement and Calibration Resource Center www.fluke.com/precision_resource_ctr New product information, e-news bulletins, total solutions newsletter, industry links, users community, used certified equipment, technical papers and application notes. Process Control Resource Center www.fluke.com/process_resource_ctr Process calibration glossary, industry information, ROI calculator, application notes, and product demos. Solve more problems with Fluke Tools Fluke is more than digital multimeters. These days, Fluke offers the ultimate go-everywhere DMM as well as specialized tools for electrical, industrial, HVAC, and electronic applications. Increasingly, technicians are using their Fluke tools together, in a one-two troubleshooting combination. Use a thermal imager to find a problem, then use a DMM, clamp meter, or power quality analyzer to fix it. Use a power logger to check power usage, use an AirMeter to optimize the HVAC system, and then log power again to see the impact of your adjustments. The online resource centers on this page can help you find the right tools for your applications, learn how to use them, and get to work. Your site-specific knowledge plus Fluke tools makes for an impressive troubleshooting team. Plus, the new generation of Fluke tools is smaller, lighter, and easier to use than ever. They meet higher safety standards. They download to reports. And they’re as reliable and tough as ever. By offering a system of tools that work together, Fluke aims to help you solve more problems, faster and better, no matter where you work. Utilities Resource Center www.fluke.com/utilities_resource_ctr Training and events information, product demos, specialized technical support, application notes, and power quality, thermography and earth ground information for utilities. Fluke... more than just tools Test tool information Since 1949 the Fluke Corporation has been dedicated to the design and manufacturing of innovative test and measurement instruments. Fluke also leads the way in providing programs, training and resources that help you stay at the forefront of your profession. FlukePlus Tool Info Online Electrical Measurement Safety Program FlukePlus is a website for test tool users who want to learn more. Sign up and get: • Product tips and “how to” articles • Previews of the newest Fluke tools • Special offers and promotions • Direct connection to Fluke technical support Get a free safety video, a summary of safety standards and helpful articles on safe electrical measurement practices. (Available only in the U.S.) www.fluke.com/flukeplus www.fluke.com/safety Test Tool Users Online Community www.fluke.com/community See what other test tool users are saying and get your questions answered, fast! The Test Tool Community online bulletin board is free and open to everyone. Fluke Education Partnership Program www.fluke.com/education We’ve teamed up with colleges, trade, technical, vocational schools, and apprenticeship programs to bring the latest application information and tools into the classroom. Currently available in USA, Canada, Brunei, Burma, India, Indonesia, Laos, Malaysia, Philippines, Singapore, Taiwan, Thailand and Vietnam. Application Notes www.fluke.com/appnotes Fluke has a complete library of application notes and white papers on topics ranging from predictive maintenance to maintaining motors and drives to automotive troubleshooting and more. Fluke News www.fluke.com/flukenews Fluke News is published two times a year with new tips, tools and articles in each issue. Fluke Electrical News For electrical contractors or electricians working in residential, commercial, or industrial environments. Fluke Plant News For electricians, electrical supervisors, field service technicians, plant technicians and process engineers maintaining industrial equipment in the field or plant. Fluke Electronics News For electronics or electrical engineers who use DMMs, benchtop meters, and oscilloscopes in prototyping, design and field evaluation situations. Fluke HVAC/IAQ News All-new articles about tools, measuring practices, and business opportunities for HVAC and Indoor Air Quality (IAQ) professionals. Fluke Test Tool Information  Safety and You Why is safety important? Why should you care? Between five and ten times on any given day, arc flash explosions, sufficient to send a victim to a special burn center, take place in the U.S. These incidents and other less serious electrical accidents result in injury —sometimes death—lost work time, medical costs and insurance claims, downtime, the list goes on. The cost to both the victim, the victim’s family and the company involved, are high. Yet many of these accidents can be prevented. The combination of training, good measurement technique, and the use of proper tools can significantly reduce the chance of an accident occurring. What are the Standards? To provide improved protection for users, industry standards organizations have Go to www.fluke.com/safety to view The taken steps to clarify the hazards present Fluke Electrical Measurement Safety Program in electrical supply environments. The and order your free copy of the Fluke Safety American National Standards Institute video. This video makes the standards easy to understand and can be used as part of (ANSI), the Canadian Standards Association your own internal safety program. (CSA), and the International ElectroTechnical Commission (IEC), have created more stringent standards for voltage test equipment used in environments of up to 1000 volts. ANSI, CSA and IEC define four measurement categories of over-voltage transient impulses. The rule of thumb is that the closer the technician is working to the power source, the greater the danger and the higher the measurement category number. Lower category installations usually have greater impedance, which dampens transients and helps limit the fault current that can feed an arc. • CAT (Category) IV is associated with the origin of installation. This refers to power lines at the utility connection, but also includes any overhead and underground outside cable runs, since both may be affected by lightning. • CAT III covers distribution level wiring. This includes 480-volt and 600-volt circuits such as 3-phase bus and feeder circuits, motor control centers, load centers and distribution panels. Permanently installed loads are also classed as CAT III. CAT III includes large loads that can generate their own transients. At this level, the trend to using higher voltage levels in modern buildings has changed the picture and increased the potential hazards. • • CAT II covers the receptacle circuit level and plug-in loads. CAT I refers to protected electronic circuits. Some installed equipment may include multiple categories. A motor drive panel, for example, may be CAT III on the 480-volt power side, and CAT I on the control side. Independent testing labs help ensure safety compliance You want your tools and equipment to help you work safely. But how do you know that a tool designed to meet a safety standard will actually deliver the performance you are paying for? Unfortunately it’s not enough to just look on the box. The IEC (International Electrotechnical Commission) develops and proposes standards, but it is not responsible for enforcing the standards. Wording like “Designed to meet specification...” may not mean a test tool actually performs up to spec. Designer’s plans are never a substitute for an actual independent test. For more information, go to www.fluke.com/safety  Safety Underwriters Laboratories (UL) Canadian Standards Association (CSA) TUV and VDE (German standards organizations) are approval/listing agencies United States Department of Labor Mine Safety and Health Administration That’s why independent testing is so important. To be confident, check the product for the symbol and listing number of Underwriters Laboratories (UL), the Canadian Standards Association (CSA), TÜV or another recognized testing organization. Those symbols can only be used if the product successfully completed testing to the agency’s standard, which is based on national/ international standards. That is the closest you can come to ensuring that the test tool you choose was actually tested for safety. What does the CE symbol indicate? A product is marked CE (Conformité Européenne) to show it conforms to health, safety, environment and consumer protection requirements established by the European Commission. Products from outside the European Union cannot be sold there unless they comply with applicable directives. But manufacturers are permitted to self-certify that they have met the standards, issue their own Declaration of Conformity, and mark the product “CE.” The CE mark is not, therefore, a guarantee of independent testing. Why are Fluke products different? Don’t be confused by “Listed” vs. “Designed to” in your test tools. IEC sets the standards but does not test or inspect for compliance. So a manufacturer can claim to “design to” a standard with no independent verification. To be UL-Listed, CSA or TUV-Certified, a manufacturer must employ the listing agency to TEST the product’s compliance with the standard. Look for the listing agency’s emblem on the meter. Service Information Think of Fluke first for technical service, repair and calibration Fluke customer support is ready to help Application note, literature code 2153519: Why calibrate test equipment? Why would a digital test tool need to be calibrated? It’s not as though any analog parts will go out of balance. Well, have any events occurred that would render your instruments less accurate or unsafe? Is accurate measurement essential to your operations? Are you trending data? Read this application note to find out what causes calibration problems and whether you should consider calibrating your test instruments. Visit www.fluke.com/why-calibrate Application note, literature code 2138394: Calibrating a thermometer. Technical service at your fingertips We know Fluke tool users put their tools through the paces, so we’re ready to answer your questions and help keep your tools in top shape. No matter what application, in what industry. And we’ll do it through real technical service professionals in Everett, Washington. When you need questions answered, call Sales and Application Support at 1-888-44-Fluke or email fluke-info@fluke.com The Fluke experts answering your call can help with just about any test tool question. They specialize in: • Advice on what to buy, from problem analysis to tool compatibility and configuration “If I’m working with three phase motors, what’s the best tool to use?” • Help on how to use your tools in any application, from automotive to industrial “How come I’m not getting a reading?” “How do I transfer my test results?” “How do I measure harmonics?” When your Fluke tools need repair or calibration, call Customer Support Services at 1-888-99-Fluke or email service.status@fluke.com. Customers outside the U.S. email service.international@fluke.com or visit www.fluke.com/service to find your nearest location. If your tool isn’t working correctly, or if you dropped it, ran over it, or dunked it in the pool, call Fluke. If it’s not under warranty, we’ll give you a cost estimate over the phone. Once you send it in, we’ll verify the problem, fix it, test it and put it back in the mail often in less than five working days. Fluke recommends having your DMMs, Calibrators and ScopeMeter test tools calibrated once a year—especially if you use them often or need accurate measurements to meet regulations requirements. Calibration compares your tool’s measurements to the accuracy standard—sort of like setting your watch to match an atomic clock. Some test tools live a pretty rough life. If you calibrate them, you know they’re accurate—even after what you put them through. Shocking treatment Because of our commitment to safety, all Fluke equipment is designed to provide as much protection as possible from the inherent dangers of working in the unsettled sea of electricity. Fluke products are dropped, shocked, short circuited, injected with thousands of volts of electricity and forced to endure extreme temperature, just to get out the door. To learn more about our product tests, visit www.fluke.com/shocking For more information on servicing your Fluke tools outside of the U.S., see page 2 for contact information. Service  Pick the right digital multimeter for you Digital Multimeter Selection Guide Models Highest True-rms and accuracy with Industrial built-in data logging troubleshooting thermometer 189 87V 179 Designed for building maintenance 117 Designed for HVAC/R technicians 116 Waterproof and chemical resistant 27 Two powerful tools in one 1587 AC AC 0.1 % 0.09 % 0.1 % • Basic features True-rms readings AC+DC AC AC AC AC Basic dc accuracy 0.025 % 0.05 % 0.09 % 0.5 % 0.5 % Wide bandwidth 100 kHz 20 kHz • • • • • • Digits 4-1⁄2 4-1⁄2 3-1⁄2 3-1⁄2 3-1⁄2 3-1⁄2 Counts 50000 20000 6000 6000 6000 3200 Voltage ac/dc 1000 V 1000 V 1000 V 600 V 600 V Current ac/dc 10 A 10 A 10 A 10 A 600 µA Resistance 500 MW 50 MW 50 MW 40 MW 40 MW Frequency 1 MHz 200 kHz 100 kHz 50 kHz Capacitance 50 mF 10 mF 10 mF 10 mF Temperature +1350 °C +1090 °C +400 °C Auto/manual ranging 4-20 mA loop diagnostics 789 30 kHz • • 3-1⁄2 6000 4000 1000 V 1000 V 1000 V 10 A 400 mA 1A 32 MW 50 MW 40 MW 50 kHz 100 kHz 20 kHz 10 mF 10 mF +400 °C +500 °C Measurements dB 60 dB Conductance 50 nS 50 nS • • Duty cycle/pulse width Motor drive measurements/low pass filter 32 nS • • Continuity with beeper • • • • • • • • Diode test • • • • • • • • • Display Dual display • Analog bargraph • • • • • Backlight • • • • • • • • • • • • • • • Data storage and exchange Min/Max recording Min/Max recording/with time stamp Fast Min/Max • • • 250 µs 250 µs Display Hold/Auto (Touch) Hold • • Relative reference • • PC interface • • Data logging • with PC Readings memories • • • • • • • 100 Other features Automatic selection, LoZ • Insulation test range 0.01 MW to 2 GW VoltAlert, non-contact ac voltage detector) • Real time clock • Overmolded case, integrated holster • Removable holster • • • • • ToolPak Magnetic Hangar compatibility • • • • • Closed case calibration • • • • • Separate battery door • • • • • Completely sealed/watertight • • • • • • • • • Automatic power off • • • • • Low battery indication • • • • • • –20 °C, +55 °C –20 °C, +55 °C –10 °C, +50 °C –10 °C, +50 °C –10 °C, +50 °C –40 °C, +55 °C Operating temperature range • • • –20 °C, +55 °C 4-20 mA • 24 V loop supply • Warranty and electrical safety Limited lifetime warranty • • • Warranty (years) Input alert Dangerous voltage indication • 3 • 3 • • • • • CAT III measurements 1000 V 1000 V 1000 V 600 V 600 V CAT IV measurements 600 V 600 V 600 V 12 14 15 17 18 See page 3 3 • • • 1000 V 1000 V 1000 V 600 V 600 V 19 35 43 More comprehensive information is available at www.fluke.com/dmm 10 Digital Multimeters Test faster and safer with a new Fluke Move up to more measurement performance and safety Move up from your old 87 and benefit from more than a dozen improvements Function Original 87 87V Benefit Selectable filter for motor drives No Yes Accurate voltage and frequency measurements on pulse width modulated signals Built-in thermometer No Yes No separate thermometer required Capacitance 5 nf to 5 µF 5 nf to 10,000 µF Measure more capacitors V dc accuracy and resolution 0.1 %, 10 µV 0.05 %, 10 µV Precise measurements in a handheld tool Display digits 13.5 mm x 7 mm 15.25 mm x 8.5 mm 30 % larger makes it easy to read Backlight Green 2-level, bright white Easier to read in dark locations Magnetic hanger No Optional (included with kit) Position meter for easy viewing Peak capture 1 ms 250 µS Record intermittent problems four times faster CAT electrical safety rating No Yes, 2nd edition ANSI and IEC 61010 Increased protection from 8 kV spikes that can cause arc flash Battery door No Yes Change battery quickly without breaking cal seal Warranty Expired Limited lifetime Lower cost of ownership 87 87V Get accurate voltage and frequency measurements on adjustable speed motor drives with the 87V. Move up from your old 8060 or 8062 and benefit from more than 20 improvements Function 8060 189 Benefit Built-in recorder with time stamp No Yes Record and view intermittent problems without a chart recorder PC interface No Yes, software optional Transfer readings to a PC for analysis and documentation Built-in thermometer No Yes, probe optional No need to carry a separate thermometer Capacitance No 5 nf to 50,000 µF Measure capacitors with one tool V dc and V ac resolution 10 µV 1 µV Precise measurements in a handheld tool dBv and dBm Yes Yes Measure communication circuits Duty cycle and pulse width No Yes Measure control circuits In-line current 2A 10 A, 1000 V fuse Safely measure five times more current Relative offset No Yes Remove test lead resistance See small signal variations Range selection Manual, 8 switches Auto/Manual range Simpler to use, more durable Peak capture, MIN/MAX No 250 µS Record intermittent problems Backlight No 2-level, bright white Easier to read in dark locations Holster No Integrated overmold Stands up to accidental drops Magnetic hanger No optional TPAK Position meter for easy viewing CAT electrical safety rating No Yes, 2nd edition ANSI and IEC Increased protection from 8 kV spikes that can cause arc flash Battery door No Yes Change battery quickly without breaking cal seal Warranty Expired Limited lifetime Lower cost of ownership 8060 189 Use the built-in data logging feature of the 189 to record readings and the time they occurred to catch intermittent problems. Move up from your old 70 or 20 series and benefit from more than 15 improvements Feature Original 77 179 Benefit True-rms No Yes Accurate on non-linear signals Accuracy, basic dc 0.3 % 0.09 % Three times more accurate Temperature No Yes No need for a separate thermometer Min/Max/Average No Yes Capture intermittent problems Display size Small 20 % larger Large, easy to read Display backlight No Yes Easy to read in dark locations Simple to use Yes Yes No retraining required Probe holders Yes Improved One-hand operation Latest electrical measurement safety standards Not rated 1000 V CAT III, 600 V CAT IV Designed to withstand 8,000 volt peak transient impulses and protect against arc flash Optional magnetic hanger No Yes Position meter in best location Warranty Expired Limited lifetime Lower cost of ownership Frequency No Yes Built in frequency counter Capacitance No Yes Measure motor capacitors and components Max. ac voltage 750 1000 Wider measurement range Battery door No Yes Change battery quickly without breaking cal seal 77 179 The ultimate multi-purpose meter, the 179 combines precision, safety and reliability to help you get any job done. Digital Multimeters 11 FlukeTools 189 Logging Test Catalog Multimeter Volume 36 Solve complex problems for electronic and industrial applications Contents The Fluke 189 is the most advanced meter with features, precision and accuracy to troubleshoot industrial and electronic equipment in the field or on the bench. The Fluke 189 has a built-in data logger to record measurements unattended. Recorded data can be viewed on the 189 or transferred to a PC with optional FlukeView® Forms software. • Built in data logger (Fluke 189) records reading and time to catch intermittent problems • True-rms, 100 KHz bandwidth for precise measurement of non linear signals • 0.025 % dc accuracy and 1 microvolt resolution for bench meter performance in a handheld package • Measure 20 A for up to 30 seconds, 10 A continuous • Temperature, capacitance, dB, frequency, pulse width and duty cycle to find more problems with one tool • Large bright white display with dual parameter readout to view multiple readings at once • Min/Max with timestamp to record signal fluctuations • Peak capture to measure transients as short as 250 µS • Isolated IR communication port to send data to a PC (with optional FVF pack) • Premium test leads and alligator clips (AC72) included • New! Optional USB data cable with FlukeView Forms • New! Optional battery pack (BP189) extends battery life to over 400 hours Log and document NEW! The 189/FVF2 Data Logging Multimeter and Software Combo Pack gives you a practical, affordable approach to predictive maintenance. • With built-in data logger, the • Electrical safety All inputs are protected to measurement CAT III 1000 V and CAT IV 600 V. Available in non-logging version as Fluke 187 • • Specifications – 189 and 187 DMMs Function Range and resolution • • Best accuracy 180 Series V dc 50.000 mV, 500.00 mV, 3000.0 mV, 5.0000 V, 50.000 V, 500.00 V, 1000.0 V ± 0.025 % V ac 50.000 mV, 500.00 mV, 3000.0 mV, 5.0000 V, 50.000 V, 500.00 V, 1000.0 V ± 0.4 % A dc 500.00 µA, 5,000 µA, 50.000 mA, 400.00 mA, 5.0000 A, 10.000 A* ± 0.15 % A ac 500.00 µA, 5,000 µA, 50.000 mA, 400.00 mA, 5.0000 A, 10.000 A* ± 0.75 % Resistance 500.00 W to 500.0 MW ± 0.05 % Capacitance 1.000 nF to 50.00 mF ± 1.00 % Frequency 500.00 Hz, 5.0000 kHz, 50.000 kHz, 999.99 kHz Temperature -200 ºC to 1350 ºC (-328 ºF to 2462 ºF) ± 0.005 % • • • 189 helps you track down elusive, intermittent problems, monitoring equipment with any of its functions, while you do other jobs Overlay data from six meters or six time periods to find cause and effect relationships or for condition monitoring applications With break-through accuracy and precision, catch events as brief as 50 ms Designed for harsh environments that would ruin most data loggers or multimeters Log up to 450 hours of data using the extended battery pack Turn data into meaningful graphs and tables using FlukeView Forms software TPAK™ Magnetic Hanger allows you to securely hang your meter for monitoring or hands-free use Soft carrying case to protect your investment USB cable included with kit ± 1 % of reading Duty cycle 10 % to 90 %, resolution 0.01 % Pulse width 2 ranges, 499.99 ms and 999.9 ms, best resolution 0.01 ms — dBm, dBv -62 to +60, resolution 0.01dB 3% 0.1 dB *10 A continuous, 20 A for up to 30 seconds and not specified. Battery life: 72 hours typical (alkaline), 450 hours typical with Battery Extender (BP189) Size (LxWxD): 203 mm x 100 mm x 50 mm (8.00 in x 3.94 in x 1.97 in) Weight: 0.545 kg (19.2 oz) Recommended accessories – 189 and 187 DMMs Included accessories Every 180 series meter comes packaged with TL71 Silicone Test Leads, probe holders, two AC72 Alligator Clips, four AA batteries (installed), CD-ROM (users manual and technical notes) and operator’s guide. Ordering information TL910 Electronic Test Probes See page 63 TL81A Test Lead Kit See page 63 C125 Meter Case See page 70 BP189 FVF-SC2 High Capacity Battery Pack FlukeView Forms Software See page 65 See page 65 For more information and detailed specifications, go to www.fluke.com/dmm 12 Digital Multimeters Fluke-189/FVF2 Logging Multimeter and Software Combo Pack Fluke-189 Logging Multimeter Fluke-187 Digital Multimeter FVF-SC2 FlukeView Forms Software w/cable FlukeView Forms Software ® Utilize this powerful tool to analyze your measurements Harness the power of the data logging function on your Fluke Digital Multimeter. FlukeView Forms offers an easy-to-use, customizable solution to help you document logged data. Easy-to-use wizards allow you to download readings from your Fluke tool and display individual readings or a series of measurements. • Graph data to help you detect trends, analyze, predict and prevent problems • Print, save and share logged data • Log live readings while connected to a PC, or leave your Fluke 189 in place to capture up to 1,000 readings for download to a PC • Display readings from up to six different meters on the same graph to show links between multiple processes, events and locations • Record and display any function the meter measures: volts, ohms, frequency, capacitance, temperature, diode testing and more • Free demo-reader download allows co-workers or clients to open your report and interact with captured data • Export data into Microsoft® Excel Customize reports using your specific data or company logo, spot trends and document interruptions or spikes. A single graph overlaying two time periods makes analysis easier. To take a test drive of the power of FlukeView Forms, download demonstration software for free at www.fluke.com/flukeviewforms Use the FlukeView designer to turn simple time and event data into fully customized reports. You can share reports and add notes to draw attention to and explain anomalies. Fluke 189, 189/FVF2 Kit and 187 capabilities 189/FVF2 189 187 Fluke 180 Series Multimeter and premium test leads • • • Fluke’s top-of-the-line multimeter with maximum feature set to troubleshoot any situation. PC connectable • • • Use to download and document test results. • • Logging capabilities FlukeView Forms software Benefit Reduce man-hours by using logging to find problems and intermittent glitches. Document and print measurement data in a clear and organized format. • Overlay and graph data from up to six meters • • Compatible with FlukeView Forms Demo Reader • • Find elusive cause/effective relationships. • Allow data to be distributed and shared with individuals throughout a company for free. Compatible with FVF-SC2 FVF-SC1 FVF-SC3 Fluke 187 and 189 Digital Multimeters, Fluke 1550B MegOhmMeter, Fluke 789 ProcessMeter™ Fluke 53-II and 54-II Thermometers Fluke 45 Bench Meter For more information and detailed specifications, go to www.fluke.com/flukeviewforms Digital Multimeters 13 Fluke 87V Industrial Multimeter Diagnostic functions for maximum industrial productivity The Fluke 87V has measurement functions, troubleshooting features, resolution and accuracy to solve more problems on motor drives, in-plant automation, power distribution and electro-mechanical equipment. New features for maximum productivity • Unique function for accurate voltage and frequency measurements on adjustable speed motor drives and electrically noisy equipment (87V and 87V Ex) • Large digit display with bright two level backlight makes the 87V significantly easier to read • Measure 20 A for up to 30 sec, 10 A continuously • Optional magnetic hanger for easy setup and viewing while freeing your hands for other tasks (TPak) • Expanded capacitance range to 10,000 µF • Built-in thermometer (87V)  pplication note, literature code A 2155830: Multimeter measurements on adjustable speed drives utilizing the Fluke 87V DMM How do I troubleshoot an adjustable speed drive with a digital multimeter? Read this and other application notes at www.fluke. com/library Electrical safety All inputs are protected to CAT III 1000 V and CAT IV 600 V. They can withstand impulses in excess of 8,000 V to help protect you from arc blast resulting from surges and spikes. Available in intrinsically safe version as the Fluke 87V Ex. Also available as 83V average responding multimeter, see below for specifications Features – 87V and 83V DMMs Feature Fluke 87V/E2 Industrial Electrician’s Combo Kit 87V Ex 87V 83V ATEX II 2G EEx ia IICT4 safety rating for use in Zone 1 and Zone 2 • True-rms ac voltage and current for accurate measurements on non linear signals • •  Selectable filter for accurate voltage and frequency measurements on motor drives • •  0.05 % dc accuracy • •  4-1/2 digit mode for precise measurements • • Built-in thermometer lets you carry one less tool • • Large display digits and two level bright white backlight for increased visibility • • • 10,000 µF capacitance range for components and motor caps • • • Peak capture to record transients as fast as 250 µs • • Measure up to 1000 V ac and dc • • • Measure up to 10 A, 20 A for up to 30 seconds • • • Auto and manual ranging for maximum flexibility • • • Analog bargraph • • • Frequency to 200 kHz and % duty cycle • • • Min/Max and average recording to capture variations automatically • • • Relative mode to remove test lead resistance from low ohms measurements • • • Access door for fast battery changes without breaking the calibration seal • • •  Make industrial troubleshooting even more productive with accessories. • 87V Industrial Multimeter • New! C35 lightweight soft case to provide optimal protection and storage • TL224 1.5 m silicone leads resist heat • TP238 removable probes with 4 mm of exposed metal for use on industrial circuits • AC220 retractable long reach alligator clips • ToolPak™ meter hanging accessory to hold meter to steel surfaces • 80BK K-type temperature probe Included accessories Specifications – 87V and 83V DMMs Basic accuracy 87V 83V 600.0 mV, 6.000 V, 60.00 V, 600.0 V, 1000 V 0.05 % 0.1 % AC volts 600.0 mV, 6.000 V, 60.00 V, 600.0 V, 1000 V 0.7 % (true-rms) 0.5 % DC current 600.0 µA, 6000 µA, 60.00 µA, 600.O mA, 6.000 A, 10.00 A 0.2 % 0.4 % AC current 600.0 µA, 6000 µA, 60.00 µA, 600.O mA, 6.000 A, 10.00 A 1.0 % (true-rms) 1.2 % Temperature (excl. probe) -200 °C to 1090 °C (-328 °F to 1994 °F) 1.0 % — 80BK Temperature Probe -40 °C to 260 °C (-40 °F to 500 °F) Resistance 600.0 W, 6.000 kW, 60.00 kW, 600.0 kW, 6.000 MW, 50.00 MW Capacitance 10.00 nF, 100.0 nF, 1.000 µF, 10.00 µF, 100.0 µF, 9,999 µF Frequency 199.99 Hz, 1.9999 kHz, 19.999 kHz, 199.99 kHz Function Range and resolution DC volts 2.2 °C or 2 % — 0.2 % 0.4 % 1.0 % 1.0 % 0.005 % 0.005 % Battery life: 400 hours typical with backlight off. Size (LxWxD): 201 mm x 98 mm x 52 mm (7.9 in x 3.8 in x 2 in). Weight: 355 g (22 oz) For more information and detailed specifications, go to www.fluke.com/dmm 14 Digital Multimeters Every Fluke 83V and 87V meter comes packaged with TL75 Test Leads, AC72 Alligator Clips, holster, 9 V battery (installed), 80BK Temperature Probe (87V only) CD-ROM (users manual and technical notes) and operator’s guide. Ordering information Fluke-87-5 Industrial True-rms Multimeter with Temperature Fluke-87-5/E2 Industrial Electrician’s Combo Kit Fluke-83-5 Industrial Multimeter Fluke 179 Digital Multimeter Versatile meters for maintenance and field service The 179 true-rms Multimeter has the features needed to find most electrical and HVAC problems. Simple to use with significant improvements over the original Fluke 70 Series like true-rms, the 179 has more measurement functions, conformance to the latest safety standards and a much larger display that’s easier to view. Features include: • Wide 1000 V measurement range • True-rms for precise measurement of non 179/EDA2 Electronics Multimeter and Deluxe Accessory Combo Kit • 179 True-rms Digital Multimeter • New! C35 lightweight soft case linear signals Capacitance, resistance, continuity and frequency Built-in thermometer (Fluke 179 only) Large, easy-to-read display Backlight for work in dimly lit areas (Fluke 177 and179 only) • Min/Max/Avg to record signal fluctuations • Free your hands with the optional TPAK magnetic hanger (Fluke TPAK) • • • • to provide optimal protection and storage • TL910 Electronic Test Probes • TL224 SureGrip™ Silicone Test Leads resist heat • AC280 SureGrip™ Heavy Duty Hook Clips • 80BK Type-K temperature probe • ToolPak™ meter hanging accessory to hold meter to steel surfaces Electrical safety All inputs are protected to measurement CAT III 1000 V and CAT IV 600 V. This meter can withstand transient impulses in excess of 8000 V to help protect you from arc blasts resulting from surges and spikes. Features – 175, 177 and 179 DMMs Feature 179 177 175 Max voltage 1000 1000 1000 •  • • 0.09 % 0.09 % 0.15 % Backlight  • • Min/Max/Avg  • •  • ToolPak meter hanging kit with magnet Opt Opt Opt True-rms Temperature  • Basic dc accuracy 179/1AC-II Electrician’s Multimeter and Voltage Tester Combo Kit • 179 True-rms Digital Multimeter • 1AC-II VoltAlert™ Non-Contact Voltage Detector Specifications – 179, 177 and 175 DMMs Function Range and resolution Best accuracy DC voltage 600.0 mV, 6.000 V, 60.00 V, 600.0 V, 1000 V ± 0.09 % (Models 177 and 179) ± 0.15 % (Model 175) AC voltage1 600.0 mV, 6.000 V, 60.00 V, 600.0 V, 1000 V ± 1.0 % of reading DC current 60.00 mA, 400.0 mA, 6.000 A, 10.00 A2 ± 1.0 % of reading AC current2 60.00 mA, 400.0 mA, 6.000 A, 10.00 A2 ± 1.5 % of reading Resistance 600.0 W, 6.000 kW, 60.00 kW, 600.0 kW, 6.000 MW, 50.00 MW ± 0.9 % of reading Capacitance 1000 nF, 10.00 µF, 100.0 µF, 9999 µF ± 1.2 % of reading Frequency3 99.99 Hz, 999.9 Hz, 9.999 Hz, 99.99 kHz ± 0.1 % of reading -40 ºC to +400 ºC (-40 ºF to +752 ºF) 1.0 % of reading Temperature (Model 179) 1All ac voltage and ac current ranges are specified from 5 % of range to 100 % of range. 210 A continuous, 20 A for up to 30 seconds. 3Voltage frequency is specified from 2 Hz to 100 kHz. Current Frequency is specified from 2 Hz to 30 kHz. Battery life: 200 hours typical for alkaline. Size (HxWxL): 4.3 cm x 9.0 cm x 18.5 cm (1.7 in x 3.5 in x 7.3 in) Recommended accessories – 179, 177 and 175 DMMs • New! C35 lightweight soft case to provide optimal protection and storage • AC220 retractable long reach alligator clips TP220 sharp 12 mm stainless steel tip provides reliable contact • TL224 1.5 m silicone leads resist heat • ToolPak™ meter hanging accessory to hold meter to steel surfaces • 80BK K-type temperature probe • Included accessories Every Fluke 170 Series meter comes packaged with TL75 test leads, 9 V battery (installed) and manual. The Fluke 179 comes with an 80BK Temperature Probe. Ordering information L210 Probe Extender with light See page 64 TL220 C510 SureGrip Industrial Carrying Case See page 70 Test Lead Set See page 61 PV350 i400s Pressure-Vacuum AC Current Clamp Module See page 66 See page 65 For more information and detailed specifications, go to www.fluke.com/dmm Fluke-179 Digital Multimeter Fluke-179/1AC-II Electricians Combo Kit Fluke-179/EDA2 Electronics Combo Kit Fluke-175 Digital Multimeter Fluke-177 Digital Multimeter Digital Multimeters 15 Fluke Family of True-rms Digital Multimeters Engineered by Fluke for working professionals Commercial electricians HVAC/R technicians Fluke 117 Fluke 116 voltage detection • LoZ low impedance input for safer troubleshooting • Resistance, continuity, frequency and capacitance • AC/DC voltage to 600 V, ac/dc current to 10 A frequency and capacitance • LoZ low impedance input for safer troubleshooting • AC/DC voltage to 600 V, ac/dc current to 600 μA • VoltAlert™ non-contact • Temperature to 400 °C • Resistance, continuity, Fluke 112 Fluke 12, 16 Field service technicians Basic electrical Fluke 115 Fluke 114 frequency and capacitance • AC/DC voltage to 600 V • AC/DC current to 10 A input for safer troubleshooting • Resistance and continuity • AC/DC voltage to 600 V • Resistance, continuity, • LoZ low impedance Fluke 110, 111 Fluke 7-600 Basic features 114 115 116 True-rms readings ac ac ac 117 ac Basic dc accuracy 0.5 % 0.5 % 0.5 % 0.5 % Digits 3-1⁄2 3-1⁄2 3-1⁄2 3-1⁄2 Counts 6000 6000 6000 6000 Voltage ac/dc 600 V  600 V 600 V  600 V Current ac/dc — 10 A 600 µA 10 A Resistance 40 MW 40 MW 40 MW 40 MW Frequency — 50 kHz 50 kHz 50 kHz Capacitance — 10 mF 10 mF 10 mF Temperature — — +400 °C — Analog bargraph • • • • Large backlit display • • • • Min/Max recording • • • • Display hold/auto touch hold • • • • • • Measurements Display Data storage and exchange Other features Automatic selection, LoZ VoltAlert, non-contact ac voltage detector For more information and detailed specifications, go to www.fluke.com/dmm 16 Digital Multimeters • • Fluke 117 and 115 True-rms Digital Multimeters Designed for commercial electricians and field service technicians Application note, literature code 1260729: Why true-rms? If you’re measuring non-linear Why true-rms? loads like variable frequency drives, solid state heater drives, or electronics, you need a true-rms tool to get accurate readings. Average responding meters will read low, up to 30 or 40 percent low in some cases. This application note explains what true-rms is and when you need it in your test tool. Fluke 117 The Fluke 117 is the ideal meter for demanding settings like commercial buildings, hospitals and schools. The 117 includes integrated non-contact voltage detection to help get the job done faster. Non-linear loads need a true-rms current clamp for accurate readings Application Note can usually be separated into one of three categories: 1. Too much current. 2. Too much heat in the electrical enclosure. 3. Faulty circuit breaker (or fuse). Your first instinct will probably be to measure the current with a current clamp while the load is on. If the current is within the circuit rating, you may be tempted to replace the circuit breaker. The 117 features include: • VoltAlert™ Technology for integrated non-contact voltage detection • AutoVolt feature for automatic ac/dc voltage selection • LoZ: low input impedance prevents false readings due to “ghost voltage” • Large display and white LED backlight to work in poorly lit areas more effectively • Compact design for one-handed operation • Min/Max/Average to record signal fluctuations • Compatible with optional magnetic hanger (ToolPak™) for hands free operation • Current measurement 20 A (30 seconds momentary; 10 A continuous) • Resistance, continuity, frequency and capacitance Figure 1. One current—two readings. Which do you trust? The branch circuit above feeds a non-linear load with distorted current. The true-rms clamp reads correctly but the average responding clamp reads low by 32 percent. Troubleshooting the electrical service feeding adjustable speed motor loads can be difficult if you don’t have the right tools. New solid state motor drives and heating controls often conduct non-sinusoidal (distorted) current. In other words, the current occurs in short pulses rather than the smooth sine wave drawn by a standard induction motor. The current wave shape can have a drastic effect on a current clamp reading. Basically, there are two types of current clamps commonly available: “average responding” and “true-rms.” The average responding units are widely used and are usually Figure 2. A computer load. Non-linear loads that cause measurement errors. Introduction lower cost. They give correct readings for linear loads such as standard induction motors, resistance heaters, and incandescent lights. But when loads are non-linear, containing semiconductors, the average responding meters typically read low. Worst case nonlinear loads include small adjustable speed drives (5 hp or less) connected line to line across two phases of a 480 V, three-phase system, solid state heater controls connected single phase to 240 V, or computers connected to 120 V. When troubleshooting a branch circuit that suffers from circuit breaker tripping (or fuse blowing), the cause of the trouble Figure 3. An adjustable speed motor load. From the Fluke Digital Library @ www.fluke.com/library Want to read more? Download this and other application notes at www.fluke.com/library Fluke 115 The new Fluke 115 is the solution for a wide variety of electrical and electronic testing applications. The 115 features include: • Large display and white LED backlight to work in poorly lit areas more effectively • Compact ergonomic design for one-handed operation • Min/Max/Average to record signal fluctuations • Resistance, continuity, frequency and capacitance Features – 117 and 115 DMMs Feature 117 115 VoltAlert™ • AutoVolt/LoZ • Analog bargraph • • Large backlit digital display • • True-rms for accurate measurements on non-linear loads • • Min/Max recording • • Display hold • • 3-1⁄2 digits • • 6000 counts • • CAT III 600 V safety rated • • Specifications – 117 and 115 DMMs Function Range and resolution Best accuracy Volts ac/dc 600 V 0.5 % + 2 Current ac/dc 10 A 1.0 % + 3 40 MW 0.9 % + 2 1 nF to 9,999 µF 1.9 % + 2 5 Hz to 50 kHz 0.1 % + 2 2V 0.9 % + 2 Resistance Capacitance Frequency Diode Recommended accessories – 117 and 115 DMMs ToolPak™ Meter Hanger See page 71 TL220 SureGrip Industrial Test Lead Set See page 61 117/322 Electrician’s Combo Kit • 117 True-rms digital multimeter with non-contact voltage detection New! C115 Deluxe carrying case with shoulder strap • 322 Compact clamp meter • TL75 Hard Point Test Lead Set • ToolPak Magnetic Meter Hanging Strap • Included accessories TL75 Test leads, holster, users manual and 9 V battery (installed). Ordering information Fluke-117 Fluke-117/322 Fluke-115 Multimeter with Non-Contact Voltage Electrician’s Combo Kit Multimeter C50 Carrying Case See page 70 For more information and detailed specifications, go to www.fluke.com/dmm Digital Multimeters 17 Fluke 116 and 114 Digital Multimeters Designed for HVAC/R technicians and electrical troubleshooting Application note, literature code 2434064: Fossil fuel heating equipment Fluke 116 This Fossil fuel heating equipment application note explains the basic principles of fossil fuel heating systems (gas and oil) and how to troubleshoot them using thermometers, DMMs, clamp meters, pressure/vacuum modules, and other accessories. The instructions cover the thermostat controls, fan controls, flame verification controls, and cad cell testing. The Fluke 116 was specifically designed for the HVAC professional. It has everything needed in an HVAC meter including temperature and microamp measurements to quickly troubleshoot problems with HVAC equipment and flame sensors. principles and troubleshooting techniques Application Note This application note was written to provide you with an understanding of the basic principles of fossil fuel heating systems and how to troubleshoot these systems using thermometers, digital multimeters (DMMs), clamp meters, pressure/ vacuum modules and other accessories. Heat pumps and forced air electric heat furnaces are discussed in other application notes available from Fluke. Heating systems principles The 116 features include: • Built in thermometer for HVAC applications • Microamps to test flame sensors • Min/Max/Average to record signal fluctuations • Large white LED backlight to work in poorly lit areas • Compact ergonomic design for one-handed operation • Min/Max/Average to record signal fluctuations • Compatible with optional magnetic hanger (ToolPak™) • Resistance, continuity, frequency and capacitance Forced-air heat is generated at a central furnace and is then distributed and delivered to the conditioned space via a duct system. A properly designed heating system will generate quiet, filtered, and comfortable air into the conditioned zone. Modern systems have been recently designed that will also filter the air electronically, modulate airflow as zone temperatures change, and bring in fresh outside air based on occupied time. There are three types of fossil fuel heating systems predominantly available on the market today. These include natural gas, liquefied petroleum (LP) and fuel oil forced-air furnaces. Fossil fuel forced-air heating Forced-air fossil fuel furnaces are factory manufactured, packaged heating units that include: • A combustion chamber designed for gas or oil DMM with microamps capability testing the flame rectification circuit. • • • • A heat exchanger A flue gas exhaust chamber A forced air circulating fan and, A controller section. Newer units often include a secondary heat exchanger to increase efficiency and an auxiliary fan for combustion gases. Since the newer units substantially cool the combustion gases, removing water vapor from the combustion gases, they often are called condensing high-efficiency furnaces. Additionally, they will have plastic flue gas piping instead of older more traditional metal flue pipe since the gas temperatures are much lower than less efficient older units. Older standard gas furnaces were 65 % to 78 % efficient, while newer high efficiency furnaces are 78 % to 85 % efficient when used with induced draft fans. Modern condensing furnaces, however, are 90-95 % efficient. Modern fossil fuel furnaces also come equipped with electronic controls for ignition, fan speed control, electronic thermostats, and safety controls. The typical operating pressure of the natural gas furnaces at the burner is 3.5 inches of water column. Natural gas is predominantly used as the preferred fuel in larger cities and communities where main gas lines are available. Fuel oil and Liquid Petroleum (LP) heating furnaces are more popular in rural communities. F ro m t h e F l u k e D i g i t a l L i b r a r y @ w w w. f l u k e . c o m / l i b r a r y Fluke 114 The new Fluke 114 is the troubleshooting tool for “go/ no-go” testing. It includes a feature to prevent false readings caused by ghost voltage. Want to read more? Download this and other application notes at www.fluke.com/library The 114 features include: • AutoVolt: Automatic ac/dc voltage selection • LoZ: Helps prevent false readings due to ghost voltage • Large white LED backlight to work in poorly lit areas • Compact ergonomic design for one-handed operation • Resistance, continuity, frequency and capacitance Features – 116 and 114 DMMs Feature 116 114 Temperature measurements • AutoVolt/LoZ • • Analog bargraph • • Large backlit digital display • • True-rms for accurate measurements on non-linear loads • • Min/Max recording • • Display hold • • 3-1⁄2 digits • • 6000 counts • • CAT III 600 V safety rated • • Function Range and resolution Best accuracy Volts ac/dc 600 V 0.5 % + 2 Current ac/dc 10 A 1.0 % + 3 +400 °C 1.0 % + 18 Resistance Capacitance (116 only) Frequency (116 only) Diode (116 only) 50 kHz 0.9 % + 2 1 nF to 9,999 µF 1.9 % + 2 5 Hz to 50 kHz 0.1 % + 2 2V 0.9 % + 2 Recommended accessories – 116 Digital Multimeter 80AK 80PK-24 80PK-8 DMM Adapter SureGrip Air Temperature Probe Pipe Clamp Temperature Probe See page 69 See page 68 See page 68 Digital Multimeters • • • Temperature and Microamps Fluke 62 Infrared Thermometer TL75 Hard Point Test Lead Set ToolPak™ Magnetic Meter Hanging Strap New! C115 Deluxe carrying case with shoulder strap New! 80PK-11 Pipe Wrap Thermocouple Fluke 80AK Thermocouple Adapter Fluke 80BK B-Type Integrated Temperature Probe Included accessories TL75 Test Leads, 80BK Integrated Temperature Probe (116 only), holster, users manual and 9 V battery (installed). Ordering information 80BK Integrated DMM Temperature Probe ships with 116 See page 68 For more information and detailed specifications, go to www.fluke.com/dmm 18 • • • • Specifications – 116 and 114 DMMs Temperature (116 only) 116/62 HVAC Combo Kit • Fluke 116 HVAC Multimeter with Fluke-116 Fluke-116/62 Fluke-114 HVAC Multimeter with Temperature and Microamps HVAC Combo Kit Electrical Multimeter Fluke 77-IV Digital Multimeter Versatile meters for field service or bench repair The new 77-4 digital multimeter has the features needed to repair most electrical and electronic problems. This meter is simple to use and has significant improvements over Fluke’s original 70 Series with more measurement functions, conformance to the latest safety standards, and a much larger display that’s easier to view. Measures • Wide 1000 V measurement range • Average responding ac measurements • 0.3 % accuracy • 10 Amps continuous • Frequency and capacitance • Resistance and continuity Features • Large display • Backlight for work in dim areas • Min / Max to record signal fluctuations • Integral holster with probe holders • Free your hands with the optional TPAK magnetic hanger • Auto and Manual ranging Made in the U.S.A. Fluke 27 waterproof multimeter Completely sealed for extreme conditions Designed for U.S. military, mining and other extreme applications. A special case with o-rings prevents water from entering the input jacks, switches and fuse door. Meets military specifications for vibration, shock and water resistance. • Waterproof design with rugged, o-ring sealer case protects rotary switch, input jacks, battery and fuse door • Operates from -15 °C to +55 °C (5 °F to 131 °F) and 95 % relative humidity Fluke 73-III Features – 77-IV Digital Multimeter Feature Old 77 New 77-IV Accuracy 0.3 % 0.3 % True-rms No No Same familiar readings Frequency No Yes Built in frequency counter Capacitance No Yes Test components Maximum ac voltage 750 1000 Min/Max/Average No Yes Capture transients automatically Display backlight No Yes Usable in dim areas Battery door No Yes Fast battery changes Probe holders No Yes One-hand operation Not rated 600 V CAT IV No Yes Overvoltage category safety rating Optional magnet hanger Benefit Same great accuracy Wider measurement range Higher level of protection Position meter in best location The Fluke 73-III product represents one of the best selling multimeter designs of all time. It’s classic simplicity combined with attractive feature set make this meter the perfect choice for electronic and automotive applications. The 73-III features include: • Average responding • Measures both amps and milliamps • Removable high impact holster • Manual or autoranging Specifications – 77-IV Digital Multimeter Function Range Best accuracy Best resolution V dc 600.0 mV to 1000 V ± (0.3 % + 1) 0.1 mV V ac 6.000 V to 1000 V ± (2.0 % + 2) 1.0 mV A dc 60.00 mA to 10 A ± (1.5 % + 2) 0.01mA A ac 60.00 mA to 10 A ± (2.5 % + 2) 0.01 mA Resistance 600.0 Ω to 50 MΩ ± (0.5 % + 1) 0.1 Ω 1 nF to 9,999 µF ± (1.2 % + 2) 1 nF 99.99 Hz to 99.99 kHz ± (0.1 % + 1) 0.01 Hz Capacitance Frequency Recommended accessories – 77-IV Digital Multimeter Fluke 77-IV included accessories TL75 test leads, 9 V battery (installed) and manual. Fluke 27 included accessories TL75 test leads, alligator clips, 9 V battery (installed) and manual. Ordering information Fluke-77-4 Digital Multimeter Fluke-73-3 Digital Multimeter Fluke-27-YEL Multimeter i400s C35 AC Current Clamp Meter Case See page 66 ToolPak™ Meter Hanger See page 71 For more information and detailed specifications, go to www.fluke.com/dmm Digital Multimeters 19 Complete automotive diagnostic tools Tools designed to help you beat the book Application note, literature code 1547394: Beat the book This amazing reference covers test procedures commonly used by experienced automotive technicians. Covers basic troubleshooting techniques and measurements using a DMM and describes Beat the Book tests for the charging system, starting system, fuel and air system, ignition system, and the body electric/engine management/ cooling system. Fluke 88V Automotive Multimeter The Fluke 88V Automotive Multimeter is designed to help automotive professionals beat the book. This DMM has more measurement functions, troubleshooting features and accuracy to solve virtually any problems on conventional and hybrid vehicles. • Automotive test functions include dc and ac voltage, resistance and current • Min/Max recording for logging the highest and lowest readings over time • Frequency measurements for magnetic sensors and ac/dc frequency signals • Duty Cycle for variable duty cycle signals with selectable trigger slope and level • Pulse width for fuel injector on time measurements • Conductance testing for secondary ignition coils • RPM measurements for DIS and conventional ignition systems • Built-in thermometer Automotive electrical diagnosis. Better diagnosis, faster repair. Application Note Work safely This application note is intended as a guide for the professional mechanic. It describes some of the test procedures commonly used by experienced technicians. However, some of the procedures require you to take certain precautions to avoid personal injury and/or damage to equipment or vehicles. Fluke cannot anticipate all possible precautions that you must take on all the different vehicles for which this guide is applicable. For this reason, you should thoroughly familiarize yourself with proper safety habits and take all precautions described in the vehicle’s repair manuals to avoid injury or damage. Testing automotive systems with an analog/digital multimeter Perhaps the most important tool you’ll use in troubleshooting auto electrical systems is the multimeter. The basic multimeter measures voltage, current and resistance, while more elaborate multimeters, such as the new Fluke 88-V, have features that can check things such as frequency, duty cycle, pulse width, make diode tests, and even measure temperature. In this application note you will find troubleshooting techniques using the high quality, affordable and popular line of Fluke analog/digital multimeters and automotive troubleshooting accessories. Fluke’s analog/ digital combination has distinct advantages over either digital or analog meters alone, and the accessories are designed to make your job easier and more profitable. Although automotive multimeters with various capabilities have been around for years, many of them didn’t have the scales and functions required for todays’ automotive applications. Hybrid, electric and fuel cell powered vehicles have special requirements, ones met with the new 88-V. Now that computers and their sensors are a part of everyday automobile troubleshooting, you need a true multimeter to do the job. The common analog type multimeter is not only inadequate, it can damage delicate computer circuitry. Both analog meters and test lights, due to their low internal resistance (input impedance), draw too much power from the device they’re testing to be used on computers. What’s more, many analog meters use 9V to power the resistance test, which is enough to destroy sensitive digital components. From the Fluke Digital Library @ www.fluke.com/library Want to read more? Download this and other application notes at www.fluke.com/library Fluke 73-III (see pg 19 for details) • Simple interface for one-handed operation • Current measurement (A and mA) • Auto or manual ranging Features – 88V and 73 DMMs Feature 88V 73 Digital display with analog bargraph • • Continuity for detecting opens and shorts • • Diode test for alternator testing • • Peak Min/Max captures intermittence as fast as 250 microseconds • Min/Max average to monitor trends in oxygen sensor values for fuel trim • Pulse width for fuel injector on time measurements • Milliamp ranges to find low current parasitic drains • Lo-Ohms (.01 W) for low resistance sensor and coil measurements • Duty cycle for pulse width modulated signals • RPM for ignition systems • Temperature for coolant and air temperature sensors • • • Dwell for points and feedback carburetors Limited lifetime warranty • For the complete diagnostics package and maximum value, pick up the 88V/A combo kit. • Includes Fluke 88 Series V • Buy accessory kits and save • • • • • • • Automotive Multimeter TL224 Heat Resistant Silicone Test Leads TP220 Removable Sharp Point Test Probes AC285 Large Jaw Alligator Clips TPAK Magnetic Hanger 80BK Temperature Probe RPM80 Inductive Pick-up Automotive Backprobe Pins Insulation Piercing Probe Packaged in a durable carrying case (C800) Fluke 88V included accessories TLK281 Automotive Test Lead Kit See page 61 TLK282 Deluxe Automotive Test Lead Kit See page 61 TL28A TL82 Automotive Test Lead Set Automotive Pin & Socket Adapter Set See page 62 See page 63 Recommended automotive accessories – 88V DMM TP81 or TP82 Insulation Piercing Probes See page 63 TP84 Oxygen Sensor Insulation Piercing Probe See page 63 TP88 Rigid Backprobe Pin Set See page 63 Ordering information TP40 Automotive Back Probe Pin Set See page 63 For more information and detailed specifications, go to www.fluke.com/dmm 20 Digital Multimeters Test leads, 9 V battery (installed), RPM pickup, carrying case and users manual. Fluke-88-5 Automotive Multimeter Fluke-88-5/A KIT Automotive Multimeter Combo Kit Fluke-73-3 Digital Multimeter Fluke 8845A and 8846A 6.5 Digit Precision Multimeters Precision and versatility for bench or systems applications The Fluke 8845A and 8846A, 6.5 digit precision multimeters have the precision and versatility to handle your most demanding measurements on the bench or in a system. Dual display offers versatile graphical capabilities: The 8845A and 8846A feature a unique graphical display that can reveal signal quality issues like drift, intermittent and stability by viewing the measurement data as a real time TrendPlot,™ Histogram or Statistics using the unique analyze mode. Wide measurement ranges: Resistance or current has been extended to cover the widest range possible. Perform 4-wire measurements easily with two leads: Patented split terminal jacks for 2x4 ohms function allow you to perform precise 4-wire measurements with only two leads instead of four. Optional Kelvin leads accessories are available to enable you to establish a 4-wire connection even in tight spaces. Systems capabilities: Both instruments include an RS-232, IEEE-488 and Ethernet interface as standard, with popular DMM emulation modes that make systems integration a simple task. Software: Transfer data points from your meter to your PC with the free copy of FlukeView Forms Basic. To customize your forms, upgrade with FVF-UG. Fluke 8845A Fluke 8846A Application note, literature code 2547797: Understanding specifications for precision multimeters A solid understanding of specifications is critical when you’re evaluating the suitability of DMMs for an application, or when you must be confident that your readings accurately reflect reality. This application note discusses some of the thinking behind DMM specifications and spec sheets. It defines the various elements of DMM specs and gives tips on how to apply them. 5NDERSTANDINGSPECIlCATIONS FORPRECISIONMULTIMETERS !PPLICATION.OTE $IGITALMULTIMETERSARETHEWORKHORSESOFTHE ELECTRONICSINDUSTRY!LMOSTALLOFTHEELECTRONIC PRODUCTSWEUSEINOURPERSONALANDPROFESSIONAL LIVESAREBUILTORSERVICEDUSINGMULTIMETERS $IFFERENT$--APPLICATIONSREQUIREDIFFER ENTDEGREESOFATTENTIONTOSPECS!TECHNICIAN CHECKINGALOGICPOWERSUPPLYCANUSEHISTRUSTY BENCH$--CONlDENTLYTOVERIFYTHATTHESUPPLY ISWITHINAFEWPERCENTOF6(OWEVER WHEN THEJOBREQUIRESTESTINGCRITICALCIRCUITS CHECKING PRECISIONCOMPONENTS MAKINGlNEADJUSTMENTS INPRODUCTION VERIFYINGCOMPLIANCEWITHINDUSTRY STANDARDS ORTAKINGMEASUREMENTSOUTSIDETHE CONTROLLEDENVIRONMENTOFTHELAB THENYOULLNEED TOEVALUATESPECIlCATIONSCAREFULLY !SOLIDUNDERSTANDINGOFSPECIlCATIONSISCRITICAL WHENYOUREEVALUATINGTHESUITABILITYOF$--S FORANAPPLICATION ORWHENYOUMUSTBECONlDENT THATYOURREADINGSACCURATELYREmECTREALITY4HIS APPLICATIONNOTEDISCUSSESSOMEOFTHETHINKING BEHIND$--SPECIlCATIONSANDSPECSHEETS)T DElNESTHEVARIOUSELEMENTSOF$--SPECSAND GIVESTIPSONHOWTOAPPLYTHEM 3PECIlCATIONSANDTHE SPECSHEET &ROMTHISFORMALDElNITIONWE CANDRAWTHECHARACTERISTICSOF GOODSPECIlCATIONS 7HENEVERWETAKEAMEASURE s #OMPLETENESSnANYFACTOR MENTWITHANYMETER WERE THATIMPACTSUNCERTAINTYIS GAMBLING7EREGAMBLINGTHAT COVERED INCLUDINGOPERAT THEINSTRUMENTISGOINGTOGIVEUS INGLIMITSSUCHASHUMIDITY THEhREALvREADING&ORTUNATELY ALTITUDE ORVIBRATION ITSAVERYSAFEBETTHATAQUALITY s #LARITYnALLEFFORTSSHOULDBE MULTIMETERWILLDELIVERREADINGS MADETOMAKETHESPECIlCA THATCOINCIDEWITHREALITY3PECIl TIONSSTRAIGHTFORWARD CATIONSQUANTIFYTHECONlDENCEOF /BJECTIVITYnDOESNOTATTEMPT s GETTINGACCURATEREADINGSANDTHE TOMISLEADFORTHESAKEOF RISKOFSEEINGINACCURATEREADINGS PROMOTION !SPECIlCATIONSDOCUMENTIS ACLEARLYWRITTENDESCRIPTIONOF !WELL WRITTENSPECIlCATION SHOULDMAINTAINTHESAMELEVEL ANINSTRUMENTSPERFORMANCE OFINTEGRITYASAMEDICALCHARTOR )TSHOULDQUANTIFYANINSTRU BANKSTATEMENT-ANUFACTURERS MENTSCAPABILITIESOBJECTIVELY UNDERWELL DElNEDOPERATING CONDITIONS MUSTSTANDlRMLYBEHINDTHEIR SPECSANDYOUSHOULDFULLYEXPECT THATTHEINFORMATIONYOUARE GETTINGISACCURATEANDCOMPLETE /NTHESPECSHEET YOUSHOULD SEEMEASUREMENTUNCERTAINTY SPECSANDMODIlERSTHATAFFECT THEUNCERTAINTY9OUWILLALSOSEE OPERATINGLIMITSTHATCONSTRAIN THEENVIRONMENTINWHICHTHE UNCERTAINTYSPECIlCATIONSWILL HOLDTRUE4HESEARESTATEDIN NUMERICALVALUESEGHUMIDITY ORWITHREFERENCETOINTERNATIONAL STANDARDSSHOCKANDVIBRATION  &IRSTLETSTAKEACLOSERLOOKAT HOWWEQUANTIFYMEASUREMENT UNCERTAINTY  Àœ “ Ê Ì … i Ê   Õ Ž i Ê ˆ } ˆ Ì >  Ê  ˆ L À > À Þ Ê J Ê Ü Ü Ü° v  Õ Ž i ° V œ “ É  ˆ L À > À Þ Want to read more? Go to www. fluke.com/library to download this and other application notes, or get info specific to your industry and sign up for Fluke News publications at www.fluke.com/subscribe. Features – 8845A and 8846A Feature 8845A 8846A Display Dual VFD Dot Matrix Resolution 6.5 Digits Continuity / Diode Test Use the built-in TrendPlot paperless chart recorder to graphically identify the extent of drift and intermittent events in analog circuits. Yes Analytical Functions Statistics, Histogram, TrendPlot™, Limit Test Math Functions Zero, Min/Max/Average, Std Dev; mx + b, dB/dBm USB Device Port — USB memory drive port Real Time Clock — Yes Interfaces RS-232, IEEE-488.2, Ethernet, USB (with optional adapter) Programming Languages/Emulation Modes Safety SCPI (IEEE-488.2), Agilent 34401A, Fluke 45 Designed to comply with IEC 61010-2000-1, ANSI / ISA-S82.01-1994, CAN / CSA-C22.2 No.1010.1-92 1000 V CAT I / 600 V CATII View results in Histogram mode to reveal stability or noise problems in analog circuits. Specifications – 8845A and 8846A 8845A 8846A Function* Range Resolution Accuracy* (%) Range Resolution Accuracy* (%) Voltage dc 1000 V 100 nV 0.0035 1000 V 100 nV 0.0024 Voltage ac (freq. 300 Hz) 750 V 100 nV 0.06 1000 V 100 nV 0.06 100 MΩ 100 µΩ 0.01 1 GΩ 10 µΩ 0.01 Current dc 10 A 100 pA 0.05 10 A 100 pA 0.05 Current ac (freq. 3 Hz to 10 kHz) 10 A 1 µA 0.10 10 A 10 nA 0.10 Freq/period 300 kHz 1 µHz 0.01 1 MHz 1 µHz 0.01 Capacitance — — — 1 nF to 0.1 F 1 pF 1 — — — -200 °C to +600 °C 0.001° 0.06° Resistance (2x4 wire) Temperature RTD *Accuracy = ± (% of reading) Size (HxWxD): 88 mm x 217 mm x 297 mm (3.45 in x 8.54 in x 11.69 in) Weight:3.6 kg (7.9 lb) One-year warranty Recommended accessories – 8845A and 8846A Precision Multimeters Handle even the most demanding measurements with high accuracy and 6.5 digit resolution. Included accessories LCI Line Power Cord, TL71 Test Lead Set, Spare Line Power fuse, Programmers Manual/User Manual on CD-ROM, FVF-BASIC FlukeView Forms Software Basic Version. Ordering information TL2X4W-PT 2x4 Wire Ohms Test Lead 2 mm probe tip TL2X4W-TWE 884X-512M 2x4 Wire Ohms USB Memory 512M Tweezer FVF-UG FlukeView Forms Software Upgrade Fluke-8845A 6.5 Digit Precision Multimeter, 35 ppm Fluke-8846A 6.5 Digit Precision Multimeter, 24 ppm For more information and detailed specifications, go to www.fluke.com/884X Digital Multimeters 21 Fluke T5 and T3 Electrical Testers Alternatives to traditional solenoid testers Fluke T5 Voltage, Continuity and Current Tester • Excellent front-line troubleshooting and measurement tool Available in 600 V and 1000 V models Digital display OpenJaw™ current measurement Rotary switch selects volts, amps and ohms functions • Heavy-duty test leads • • • • Fluke T3 Voltage and Continuity Tester • LED voltage indicators • Seven key voltage levels • Automatically switches to continuity beeper or • Fluke 9040 Rotary Field Indicator The Fluke 9040 is a premium phase rotation tester with a CAT III, 600 V rating. The frequency range is from 15 Hz to 400 Hz for demanding applications. The clear liquid crystal display and the holster make it suitable for rough outdoor applications. This instrument is supplied with three unique, expandable, test probes which fit most sockets. For more information, visit www.fluke.com/9040 ac/dc voltage Heavy-duty test leads Fluke 1AC-II/1LAC-II VoltAlert Specifications – T5 and T3 Testers T5-1000 T5-600 T3 Measure dc voltage 1000 V 600 V Preset 6 V, 12 V, 24 V, 36 V, 48 V, 110 V and 220 V* Measure ac voltage 1000 V 600 V Preset 24 V, 48 V, 120 V, 208 V, 240 V, 277 V and 480 V* Measure ac current (average) 100 A 100 A N/A Measure continuity < 25 W < 25 W < 20,000 W Measure resistance N/A 1000 W 1000 W DC polarity indicator Yes Yes Yes Detachable probe tips with optional probe tips styles Yes Yes N/A 1000 V Overvoltage CAT III 600 V Overvoltage CAT III 1000 V Overvoltage CAT III Two-years Two-years One-year Safety rating Warranty * Voltage levels will vary depending on country of intended use. The pocket-sized voltage detector The next generation VoltAlert™ ac non-contact voltage testers from Fluke are easy to use—just touch the tip to a terminal strip, outlet, or supply cord. When the tip glows red and the unit beeps, you know there is voltage present. Electricians, maintenance, service, safety personnel and homeowners can quickly test for energized circuits in the workplace or at home. Certified up to CAT IV 1000 V. Two models to choose from: • 1AC-II – detects voltage from 90 V ac to 1000 V ac • 1LAC-II – detects voltage from 20 V ac to 90 V ac Included accessories The T5-1000 and T5-600 come with detachable probes and instruction sheet. The T3 has fixed test leads and probes. Buy Electrical Tester Kits and Save Ordering information T3 Tester Kit Combo kit includes: • Fluke T3 Voltage and Continuity Tester • Fluke VoltAlert™ T5-1000 Tester Kit Combo kit includes: • Fluke T5-1000 Voltage Electrical Tester • Fluke VoltAlert™ • Fluke H5 Holster VoltAlert™ Multi Pack Includes five Fluke VoltAlerts. The special kit pricing gets you the fifth VoltAlert™ free. Outfit your entire staff. Recommended accessories – Electrical Testers H5 Electrical Tester Holster See page 70 AC285 (T5) SureGrip™ Alligator Clips See page 62 Meter Cleaner Cleaning Wipes See page 71 T5 Kit Starter Kit See page 61 For more information and detailed specifications, go to www.fluke.com/tseries 22 Electrical Testers C520A Leather Tool Case See page 70 T5-1000 1000 V Voltage, Continuity and Current Tester T5-600 600 V Voltage, Continuity and Current Tester T3 Voltage and Continuity Tester T3-1AC Kit Voltage and Continuity Tester Kit T5-H5-1AC Voltage, Continuity Kit and Current Tester Kit 1AC-II 5PK VoltAlert 5 Pack 1AC-II Voltage Detector 1LAC-II Voltage Detector 9040 Rotary Field Indicator Fluke 1625 and 1623 Geo Earth Ground Testers Advanced technology for all your earth ground testing applications The new Fluke 1620 Series Earth Ground Testers not only measure ground resistance using the classic ‘fall of potential test’ but also enable time saving testing using the ‘selective’ and ‘stakeless’ methods. ‘Selective’ testing does not require the electrode under test to be disconnected during the measurement, thus increasing safety. The simple ‘stakeless’ method quickly checks ground connections using two current transformers (probes) clamped around the ground conductor under test. Offering ‘one-button’ simplicity, the 1623 is an all-in-one earth ground tester, while the 1625 has extra versatility for more demanding applications. Fluke 1623 Earth ground resistance and soil resistivity should be measured when: • Designing earth ground systems • Installing new ground system and electrical equipment • Periodically testing ground and lightning protection systems • Installing large electrical equipment such as transformers, switchgears, machines, etc. Brochure, literature code 2633834: Earth Ground Resistance: Principles, testing methods and applications This brochure is a highly informative collection of information about Earth Ground Systems, testing methods and applications. Principles, testing methods and applications Diagnose intermittent electrical problems Avoid unnecessary downtime Learn earth ground safety principles Want to Earth Ground Resistance read more? Download this and other application notes at www.fluke.com/library The 1623 is perfect for performing predictive maintenance checks of commercial and industrial applications. The 1625 is intended for electrical utility or other high frequency environments. Fluke 1625 Features – 1625/1623 Earth Ground Testers Feature 1625 3- and 4-pole earth ground measurement • • 4-Pole soil resistivity testing • • 2-Pole resistance measurement ac • • 2-and 4-pole resistance measurement dc • Selective testing, no disconnection of ground conductor (1 clamp) • • Stakeless testing, quick ground loop testing (2 clamps) • • Measuring frequency 128 Hz • Earth impedance measurement at 55 Hz • Automatic frequency control (AFC) (94 Hz to 128 Hz) • Measuring voltage switchable 20/48V • Programmable limits, settings • Continuity with buzzer • Dust/water resistance IP56 IP56 CAT II 300 V CAT II 300 V Safety rating Battery type: 6 x AA alkaline cells Size (HxWxD): 110 mm x 180 mm x 240 mm (4.33 in x 7.08 in x 9.45 in) Weight (including batteries): 1623 Geo: 1.1 kg (2.42 lb); 1625 Geo: 1.5 kg (3.31 lb) Two-year warranty EI-1623 Selective/stakeless clamp set for 1623 EI-1625 Selective/stakeless clamp set for 1625 ES-162P3 Stake/reel set for 3 pole measurements Included accessories Fluke 1625 Tester: 2 test leads, 2 alligator clips, and users manual. Fluke 1625 Kit: Same as above plus stake/reel set 4 pole, selective/ stakeless clamp set, and rugged carrying case. Fluke 1623 Tester: 2 test leads, 2 alligator clips, and users manual. Fluke 1623 Kit: Same as above plus stake/reel set 4 pole, selective/ stakeless clamp set, and rugged carrying case. Ordering information Recommended accessories – 1625 and 1623 Earth Ground Testers 1623 • One-button measurement concept ES-162P4 Stake/reel set for 4 pole measurements Fluke-1625 Advanced GEO Earth Ground Tester Fluke-1625 Kit Advanced GEO Earth Ground Tester Kit Fluke-1623 Basic GEO Earth Ground Tester Fluke-1623 Kit Basic GEO Earth Ground Tester Kit These products are for unpowered installations measuring grounding connections. For more information and detailed specifications, go to www.fluke.com/egt Earth Ground Testers 23 Fluke 1630 Earth Ground Clamp Meter Measure earth ground loop resistance anywhere. Quickly and easily. The Fluke 1630 Earth Ground Clamp is able to measure ground loop resistances—using the Stakeless testing method. This test technique eliminates the dangerous, and time consuming activity of disconnecting parallel grounds, as well as the process of finding suitable locations for auxiliary ground stakes. You can also perform earth ground tests in places you have not considered before: inside buildings, on power pylons or anywhere you don’t have access to soil. With the Stakeless testing method, the Fluke 1630 Earth Ground clamp is placed around the earth ground rod or the connecting cable. No earth ground stakes are used at all. A known voltage is induced by one half of the clamp and the current is measured by the other half. The tester automatically determines the ground loop resistance at this grounding connection. Gone are the days of spending time placing and connecting stakes for each earth ground rod on your system—a major time saver. • Quick and easy use—no earth ground stakes are necessary • Large, 35 mm (1.35 in) jaw opening • Measures ground resistance from 0.025 Ω to 1500 Ω • Measures ground leakage current from 0.2 mA to 30 mA • High and Low alarming • Automatic self calibration • Rugged carrying case and resistance check loop included What is ground, and what does it do? The NEC, National Electrical Code, defines a ground as a “conducting connection, whether intentional or accidental between an electrical circuit or equipment and the earth, or to some conducting body that serves in place of the earth.” When talking about grounding it is actually two different subjects, earth grounding and equipment grounding. Earth grounding is an intentional connection from a circuit conductor usually the neutral to a ground electrode placed in the earth. Equipment grounding is to ensure that operating equipment within a structure is properly grounded. These two grounding systems are required to be separate except for a connection between the two systems to prevent differences in potential from a possible flashover from a lightning strike. The purpose of a ground besides the protection of people, plants and equipment is to provide a safe path for the dissipation of fault currents, lightning strikes, static discharges, EMI and RFI signals and interference. Handy GEO Earth Ground Tester Earth ground tester for resistance measurement The Handy GEO Earth Ground Tester is a rugged, easy-to-use tester for three-pole ground resistance measurements and two-pole ac resistance measurements. Earth ground resistance is measured by installing earth ground test electrodes and testing with the Handy GEO. Earth ground resistance measurements are used to ensure safe operation and reduce power quality problems. The Handy GEO is extremely lightweight making it ideal to test for lightning protection levels and periodic check-ups during routine maintenance. Two-pole ac resistance is measured to confirm low resistance between electrical joints: • Fuse-to-fuse holder (to ensure there is no overheating) • Bonding of ground earth connections • Additional bonding • Cable to terminal connections AC current can be used to confirm the low resistance path in two directions simultaneously. The gold standard for measuring ground resistance using classic fall of potential as well as selective and stakeless methods. Included accessories Fluke 1630 Clamp Meter: Rugged carrying case with belt, resistance test loop, 9 V battery and users manual. Handy GEO Tester: Rugged rubber holster with carrying belt, battery, and operating instructions. Ordering information Fluke-1630 Handy GEO Handy GEO Kit Earth Ground Clamp Meter Earth Ground Tester Earth Ground Tester Kit with 25 m and 50 m cable reel and two earth ground stakes These products are for unpowered installations measuring grounding connections. For more information and detailed specifications, go to www.fluke.com/egt 24 Earth Ground Testers Fluke 430 Series Three-Phase Power Quality Analyzers Pinpoint power problems faster, safer and in greater detail Fluke 435 Fluke 434 The Fluke 435 and 434 Three-Phase Power Quality Analyzers help you locate, predict, prevent and troubleshoot problems in three- and single-phase power distribution systems. Troubleshooting is faster with on-screen display of trends and captured events, even while background recording continues. The new IEC standards for flicker, harmonics, and power quality are built right in to take the guess work out of power quality. • Troubleshoot real-time: Analyze the trends using the cursors and zoom tools—even while background recording continues • AutoTrend: Every measurement you see is always automatically recorded, without any setup • Automatic Transient Mode: Capture 200 kHz waveform data on all phases simultaneously up to 6 kV • Measure all three phases and neutral: With included four current probes • Fully Class-A compliant: Conduct tests according to the stringent international IEC 61000-4-30 Class-A standard • System-Monitor: Up to ten power quality parameters on one screen according to EN50160 power quality standard • Inrush mode: For troubleshooting nuisance circuit breaker tripping • Logger function: Configure for any test condition with memory for over 400 parameters at user defined intervals  pplication note, literature code A 2435490: Six simple ways to reduce costs with a Fluke 434 Power Quality Analyzer There are hundreds of power quality measurements you can take on electrical systems and equipment. These instructions focus on four predictive maintenance (PdM) measurements and two power consumption measurements that can help you uncover hidden costs, protect equipment from damaging conditions, reduce unscheduled downtime, and improve system performance. Features – 435 and 434 PQ Analyzers Features 435 434* Measures voltage, current, dips, swells, interruptions, harmonics, inter-harmonics, flicker, power, energy, transients, frequency, unbalance, inrush, EN50160 overview • • Logger function with multi-parameter logging • optional* Mains signaling • optional* Memory size 16 MB 8 MB Current probes 3000 A flexible (4) 40 A/400 A clamp (4) Carrying case water-tight hard case with rollers rugged hard case Software Fluke Power Log and FlukeView® FlukeView® *Optional functionality can be added with upgrade kit. Recommended accessories – 435 and 434 PQ Analyzers Included accessories Fluke 435 Analyzer: Hard carrying case with rollers, four flexible current probes (i430-flex), five test leads and clips, battery charger, FlukeView software, Power Log software, optical USB cable, color localization set, getting started manual, users manual on CD-ROM. Fluke 434 Analyzer: Hard carrying case, four current probes (i400s), five test leads and clips, battery charger, FlukeView software, optical USB cable, color localization set, getting started manual, users manual on CD-ROM. Ordering information I5sPQ3 3 pack of 5 A precision current clamps i430-flex-4pk C435 4 pack of 3000 A Water-tight hard flexible current case with rollers probes GPS430 GPS time synchronization module For more information and detailed specifications, go to www.fluke.com/pq Fluke-435 Three-Phase Power Quality Analyzer Fluke-434 Three-Phase Power Quality Analyzer Power Quality Analyzers 25 Fluke 43B Power Quality Analyzer Power quality analysis plus a scope and a meter Application note, literature code 2391563: The costs of poor power quality The Fluke 43B Power Quality Analyzer performs the measurements you need to maintain power systems, troubleshoot power problems, and diagnose equipment failures. The 43B has 20 storage locations and can store data as well as screens. • • • • • • • Productivity is the key to survival in today’s global competitive environment. Power quality problems can cause processes and equipment to malfunction or shut down. And the consequences can range from excessive energy costs to complete work stoppage. Obviously, power quality is critical. To reduce your power bill, you need to record consumption patterns and adjust the system and load timing to reduce one or more of the following: 1. Actual power (kWh) usage 2. Power factor penalties 3. A peak demand charge structure NiMH battery provides extended operating time of 6.5 hours Voltage, current and power harmonics up to 51st Total harmonic distortion (THD) Phase angle of individual harmonics FlukeView® software with enhanced analysis and documentation capabilities Continuously measure volts and amps cycle-by-cycle for up to 16 days Cursors give time and date of sags and swells Want to read more? Download this and other application notes at www.fluke.com/library Specifications – 43B Analyzer Function • Fluke 43B* Volts/Amps/Hz Volts rms ± (1 % + 10 counts) Amps rms ± (1 % + 10 counts) Frequency (Hz) ± (0.5 % + 2 counts) Crest Factor (CF) ± (5 % + 1 count) Sags and swells ± (2 % +10 counts) Power W, VAR, VA PF, Cos ( (DPF) ± (2 % + 6 counts) ± 0.04 Harmonics and THD Harmonics ±3% THD ± 3% Transient display Minimum transient detection Inrush current 40 ns ± 5 % of full scale Additional capabilities AutoTrend • Real time scope • Ohms, diode, continuity, capacitance Memory (screens/data) FlukeView software and interface cable • 20 (screens, settings, data) Standard Battery life: Rechargeable NiMH pack (charger included), 6.5 hours typical (continuous) Shock and vibration: Mil 28800E, Type 3, Class III, Style B Operating temperature: 0 ºC to 50 ºC (32 ºF to 122 ºF) Case: IP51 (dust, drip waterproof) Size (HxWxD): 232 mm x 115 mm x 50 mm (9.1 in x 4.5 in x 2 in) Weight: 1.1 kg (2.5 lbs) Safety: IEC 1010-1, CAT III 600 V. Tested and approved to UL 3111-1, CSA C.22.2 No. 1010.1-92. Warranty: Three-years on Fluke 43B, one-year on accessories Watts, power factor, displacement power factor, VA and VAR • Voltage and current waveforms • Calculates threephase power on balanced loads from a single-phase measurement • Catch up to 40 voltage transients and waveform distortions *Not including current probe specifications Included accessories The Fluke 43B includes a hard case, voltage and current probes, FlukeView® software, power quality instructional CD, USB interface cable, line voltage adapter/battery charger and users manuals. Recommended accessories – 43B Analyzer i1000s i2000flex AC Current Probe AC Current Clamp See page 66 See page 66 TLK225 SureGrip Master Accessory Kit See page 61 C43 Carrying Case See page 70 For more information and detailed specifications, go to www.fluke.com/pq 26 Power Quality Analyzers Ordering information Fluke-43B Power Quality Analyzer Fluke 1760 Power Quality Recorder Topas cal Sa tri The Fluke 1760 Three-Phase Power Quality Recorder is the ideal portable instrument for power quality experts. It is fully compliant to IEC 61000-4-30 Class-A, for advanced power quality analysis and consistent compliance testing. Designed for analysis of utility and industrial power distribution systems, in medium- and lowvoltage networks, the Fluke 1760 provides the flexibility to customize thresholds, algorithms, and measurement selections. It captures the most comprehensive details on user-selected parameters and allows for later analysis and reporting. ty fe Ele c Class-A compliance for the most demanding power quality tests 1000 V CAT III 600 V CAT IV • • • • • Fully Class-A compliant: Conduct tests according to the stringent international IEC 61000-4-30 Class-A standard GPS time synchronization: Correlate data with events or datasets from other instruments, with precision Flexible and fully configurable thresholds and scale factors: Allows user to pinpoint specific issues by defining the detailed criteria for detection and recording of disturbances. Highest safety rating in the industry: 600 V CAT IV/1000 V CAT III rated for use at the service entrance Uninterrupted power supply (40 minutes): Never miss important events—even record the beginning and end of interruptions and outages, to help determine the cause • • • • • 10 MHz, 6000 Vpk waveform capture: Get a detailed picture of even the shortest event 2 GB data memory: Enables detailed, simultaneous recording of numerous power parameters for long periods of time Comprehensive software included: Provides trend diagrams for root cause analysis, statistical summaries, report writing, and real-time data monitoring in the online mode Plug and play: Allows quick setup with automatic sensor detection; sensors are instrument powered, eliminating the need for batteries Rugged field design: Insulated housing and a solid state design with no rotating components, enable reliable testing under nearly any conditions For more information and detailed specifications, go to www.fluke.com/pq Fluke 1650 RPM Power Recorder Power recorder Fewer connections, shorter set up, less mistakes. Patented Full-Disclosure technology captures every measurement, every event, on every cycle, all the time—without thresholds. From simple set-ups to finished reports, the Fluke 1650 is the complete solution to your portable power recording needs. The Power Recorder is all you need to record, analyze, and document: • Loading and load interaction • Power consumption and demand • Sags, swells, harmonics or transient events • Ground currents • Phase relationships, including phase imbalance Multipoint For permanent installations, select Multipoint to get the same performance as the portable Power Recorder—simultaneously measuring all power quality parameters, as well as power consumption and harmonics. Application note, literature code 2555030: What does Class A mean to me? The new IEC 61000-4-30 Class A standard takes the guesswork out of selecting a power quality instrument. The standard IEC 610004-30 Class A defines the measurement methods for each power quality parameter to obtain reliable, repeatable and comparable results. It also defines the accuracy, bandwidth, and minimum set of parameters. Going forward, manufacturers can begin designing to Class A standards, giving technicians a level playing field to choose from and increasing their measurement accuracy, reliability, and efficiency on the job. Included accessories Fluke 1760 Recorder: Voltage probes (4), current probes (4), ethernet cable for network connection (1), crosslink ethernet cable for direct PC connection (1), mains cable (1), GPS time sync receiver, PC software on CD-ROM, operators manuals and carrying case. Fluke 1650 Recorder: Five flexible current probes (four 1000 A and one 100 A), PAS software with report writer, ethernet cable and manual. Ordering information Fluke-1760 Fluke-1760TR 1695-Flexi Pack Without fast transient, voltage or current option With fast transient option Power Recorder These power quality recorders are sold exclusively through power quality representatives. To request a demonstration, or to order, call 1-888-257-9897 or email questions to fpqsupport@fluke.com. Many configurations and accessories are available for these recorders, go to www.fluke.com/pq for more information. For more information and detailed specifications, go to www.fluke.com/pq Power Quality Analyzers 27 Fluke 1740 Series ThreePhase PQ Loggers Memobox Assess power quality and conduct long-term studies with ease Fluke 1744/1743 Fluke 1745 Compact and rugged, the Fluke 1740 Series Three-Phase Power Quality Loggers are everyday instruments for technicians who troubleshoot and analyze power distribution systems. Capable of simultaneously logging up to 500 parameters for up to 85 days and capturing events, the Fluke 1740 Series helps uncover intermittent and hardto-find power quality issues. The included PQ Log software quickly assesses the quality of power at the service entrance, substation, or at the load, according to the latest EN50160 standard. • Plug and play: Setup in minutes with automatic current probe detection and powering • Installs inside the cabinet: Compact, fully-insulated housing and accessories fit easily in tight spaces, next to live power • Determines the root cause: Included PQ Log software quickly analyzes trends, creates statistical summaries, and generates detailed graphs and tables • Monitors power for the long-term: Data can be downloaded during recording without interruption • Measure voltage with premium accuracy: IEC610004-30 Class-A compliant voltage accuracy (0.1 %) • Quickly validate quality of power: Assess power quality according to EN50160 power quality standard, with statistical overview • Rugged and reliable: Designed for everyday field use, with no moving parts and durable, insulated case, with two-year warranty Application note, literature code 2646555: Power quality recording and analysis: Techniques and applications Hooking up a power quality recorder and taking days’ worth of data can give you a rich picture of your power. In this article we’ll talk about the various recording techniques available in power loggers and recorders-understanding the tools and techniques you have available will be key to your strategy. What should you be looking for? And when does recording make sense? Power quality recording and analysis: Techniques and applications Application Note Hooking up a power quality recorder and taking days’ worth of data can give you a rich picture of your power. In this article we’ll talk about the various recording techniques available in power loggers and recorders—understanding the tools and techniques you have available will be key to your strategy. What should you be looking for? And when does recording make sense? Recording techniques To really know your power, ideally, you’d want to look at every line cycle to see even the smallest changes. However, since our power swings through more than four million cycles per day, it’s impractical to look at tiny changes—and often unnecessary. Few loads even notice occasional voltage dips of one or two cycles. How long you record depends somewhat on the rhythm of your building. If you are working on a typical commercial or light industrial building, then a week is long enough for a building to go through its normal cycle. If you are working in a plant that runs special equipment only periodically (say a furnace that runs only monthly), you’ll need to be sensitive to the timing of these loads. Different recording techniques have been developed to look at small changes over relatively long time periods. Many instruments combine several techniques to improve their coverage. We’ll describe the common techniques and some of their pros and cons. By understanding the different techniques. you’ll be better able to choose an appropriate tool for the job at hand. Setting up a Fluke 1735 Power Logger at the service entrance for a 30-day load study. F ro m t h e F l u k e D i g i t a l L i b r a r y @ w w w. f l u k e . c o m / l i b r a r y Want to read more? Go to www. fluke.com/library to download this and other application notes, or get info specific to your industry and sign up for Fluke News publications at www.fluke.com/subscribe. Features – 1740 Series PQ Loggers Features 1745 1744 1743 Measurement of common power parameters: V, A, W, VA, VAR, PF, energy, flicker, voltage events, and THD • • • Measurement of voltage and current harmonics to the 50th, unbalance, and mains signaling • • Dust/water resistance Display UPS ride-through Dimensions (HxWxD) IP50 IP65 water proof LED + LCD LED LED 5 hours 3s 3s 282 mm x 216 mm x 74 mm (11.5 in x 8.8 in x 3 in) 170 mm x 125 mm x 55 mm (6.9 in x 5.1 in x 2.2 in) Recommended accessories – 1740 Series PQ Loggers MBX CLAMP 1 A/10 A + N 3-phase+N current clamps 2 m cable MBX 300 POLESET Pole mounting kit for 1743 and 1744 C435 Water-tight hard case with rollers For more information and detailed specifications, go to www.fluke.com/pq Fluke VR101S Voltage Event Recorder System Power tools for power quality The VR101S is the perfect system for catching sags, swells, transients, outages, and frequency variations on line voltage at receptacles. The VR101S is a starter system that includes a compact VR101 event recorder, an optical interface cable, and EventView® software that turns your PC into a power quality reporting tool. The VR101S is covered by a one-year warranty. For more information and detailed specifications, go to www.fluke.com/vr101 28 Power Quality Analyzers Included accessories Fluke 1740 Series: 4 Flexible probes 15/150/1500/3000 A with 2 m cable, PQ Log software, RS-232 interface cable and RS-232-USB adapter, 4 black dolphin clips, test leads for voltages and power supply, color localization kit, carrying bag, test certificate with measurement values, printed English manual and multi-language manual CD. VR101S: VR101, optical interface cable, and EventView software on CD. VR101: Instruction sheet. Ordering information Fluke-1743 Fluke-1744 Fluke-1745 VR101S VR101 Power Quality Logger – Memobox Power Quality Logger – Memobox Power Quality Logger – Memobox Voltage Event Recorder System Voltage Event Recorder Note: At least one VR101S is required for proper operation. Fluke 1735 Three-Phase Power Logger Electrical load studies, energy consumption testing, and general power quality logging The Fluke 1735 Three-Phase Power Logger is the ideal electrician or technician’s tool for conducting energy studies and basic power quality logging. Set up the 1735 in seconds, with the included flexible current probes and color display. The 1735 logs most electrical power parameters, harmonics and captures voltage events. Application note, literature code 2584800: 30 Day Load Studies with the Fluke 1735 Power Logger Day Load When a build- 30 Studies with the Fluke 1735 Power Logger ing owner wants you to add new loads to an existing service or set of feeders, the first thing you have to is determine whether the existing system will support the new loads. If you have a 600 amp service installed in a facility, can you add another 100 amps of load? To answer this question you have to ask another one: What is the highest load the system carries now? Often, local electrical authorities will need to know these answers before they issue permits. Application Note When a building owner wants you to add new loads to an existing service or set of feeders, the first thing you have to is determine whether the existing system will support the new loads. If you have a 600 amp service installed in a facility, can you add another 100 amps of load? To answer this question you have to ask another one: What is the highest load the system carries now? Often, local electrical authorities will need to know these answers before they issue permits. You’ll also need a comprehensive understanding of today’s loading to evaluate the new system, once installed. To determine the existing equipment’s capacity, factor in the incoming conductor size, the ratings of the equipment, and space for new circuits. To determine present loading, you’ll need to either precisely calculate the existing loads, or measure them. Article 220 of the 2005 National Electrical Code offers two measurement methods for determining existing loads and the maximum demand the system is likely to handle. The NEC defines demand as the power consumption of the loads averaged over 15-minute intervals. The primary NEC method is to find the maximum demand during a one-year period. This only works if you have a year’s worth of demand data. The alternate method is to record the demand over a 30-day period and find the maximum demand. This article describes the 30-day recording method, known as a load study. The NEC specifies that: • The highest demand is the highest demand among all feeders. • Take the measurements when the building is occupied. • Include heating or cooling loads, whichever is larger, or correct to account for these loads. • Add in any other periodic loads. As always, local authorities are responsible for interpreting the Code and measurements. Local regulations determine when a load study must be performed, exactly what information is required, and the review process. Make sure you understand your local requirements before you start a load study. Recording Current and Power with the Fluke 1735 The compact, rugged Fluke 1735 Power Logger is an excellent tool for performing load studies. • It includes flexible current probes for connecting around multiple conductors or bus bars. • It has a PC interface and software for downloading measurements to a Windows-based PC and creating professional reports for your electrical plans. • It measures voltage on three phases and current on three phases and neutral. • It records multiple parameters that can help determine system load, including voltage, current, frequency, real power (kW), From the Fluke Digital Library @ www.fluke.com/library • Record power and associated parameters for up to 45 days • Monitor maximum power demand over user-defined averaging periods • Prove the benefit of efficiency improvements with energy consumption tests • Measure harmonic distortion caused by electronic loads • • • • • Improve reliability by capturing voltage dips and swells from load switching Easily confirm instrument setup with color display of waveforms and trends Measure all three phases and neutral with included 4 flexible current probes View graphs and generate reports with included Power Log software Compact, rugged design with IP65 case, 600 V CAT III and two-year warranty Recommended accessories – 1735 Three-Phase Power Logger MBX Clamp 1 A/10 A 3 precision dual range current clamps (1 A/10 A) MBX Clamp 5 A/50 A +N 4 precision dual range current clamps (5 A/50 A) Want to read more? Go to www. fluke.com/library to download this and other application notes, or get info specific to your industry and sign up for Fluke News publications at www.fluke.com/subscribe C435 Water-tight hard case with rollers Norma 4000 and 5000 High Precision Power Analyzers The Norma High Precision Power Analyzers deliver precise measurements of single or three-phase current and voltage as well as calculation of power and other derived values. They provides class-leading accuracy for any waveform, frequency or phase shift. Its 144 mm (5.7 in) color display makes it easy to use both in the field and as a table unit in labs and on test benches. Configurations Included accessories Fluke 1735 Logger: Four flexible current probes (15 A/150 A/3000 A), Power Log software, voltage leads and clips, color localization set, PC interface cable, international ac adapter (115/230 V, 50/60 Hz), soft carrying case, printed English manual and multi-language manual CD. Number of channels NORMA 4000: 1 phase or 3 phase; NORMA 5000 and 2x3 phases Basic accuracy 0.05 % to 0.3 % ± rdg depending on options Sample rate 1 MHz, 1/3 MHz or 0.1 MHz depending on options Ranges Up to 100 V and 10 A or 20 A direct inputs, depending on model. With shunts, transducer or clamp accessories – up to 300 A. Mechanical power Optional process interface 4 x speed/torque/Pmech Interfaces RS-232, optional IEEE 488.2/1, Ethernet, USB Norma 4000/5000 Analyzers: Test certificate with calibration values, user manual, power supply cable and are completely customizable with a variety of accessories. RMS values V/A/P/Q/S and derived values like Fundamental, THD ... Ordering information Oscilloscope Simultaneous display of up to three values on sample level FFT Up to H40 or half of sampling rate Recorder Display of three average values over time for trend determination Vector Display of Fundamental of all channels Functions Fluke-1735 Three-Phase Power Analyzer Norma 4000 BU43 High Precision Power Analyzer Norma 5000 BU56 High Precision Power Analyzer For more information and detailed specifications, go to www.fluke.com/pq Power Quality Analyzers 29 Fluke 345 Power Quality Clamp Meter The ideal meter for commissioning and troubleshooting modern electrical loads With a bright color display to analyze the harmonic spectrum, a low-pass filter to remove high frequency noise, and a high EMC immunity design, the Fluke 345 is ideal for measurements on switching loads such as variable speed drives, electronic lighting and UPS systems. Additionally, the Hall Effect measurement system makes measurement of dc current possible without the need to break the circuit, and the internal memory enables long-term logging for analysis of trends or intermittent problems. • AC/DC current: Clamp-on measurement of ac peak and dc current up to 2000 A without breaking the circuit • Highest safety rating: 600 V CAT IV/1000 V CAT III rated for use at the service entrance • Accurate measurement of parameters: Even with distorted waveforms present on electronic loads with low-pass filter • Data logging: Identify intermittent faults by logging any power parameters for minutes or months, including harmonics • Verify batteries: Direct measurement of dc ripple (%) for battery and dc systems • Troubleshoot harmonics: Analyze and log harmonics digitally or graphically • Inrush current: Capture and analysis from 3 seconds to 300 seconds • Easy-to-use: Easily confirm instrument setup with large backlit color display of waveforms and trends • Three-Phase power: Built in capability for balanced loads. • View graphs and generate reports: with included Power Log software Application note, literature code 2722823: Basic power quality measurements on the go with the Fluke 345 A great introduction to Basic power quality power quality, measurements on the go with the Fluke 345 this short application note teaches the basics of simple voltage, current, waveform, harmonics, power, inrush, and logging measurements using the Fluke 345. Learn how to read waveforms and how and where to use them, and then learn about harmonics and how they distort voltage and current. Application Note During your day-to-day measurement activities, there may be situations where you need to know more than what voltage or current is present. When that happens, the standard clamp meter isn’t going to get the job done. The solution may be a power quality clamp meter such as the Fluke 345. A power quality clamp meter like the Fluke 345 combines a clamp meter, power quality meter, oscilloscope and data logger in one. This combination of functions coupled with high quality digital filtering makes it ideal for working with variable speed motor drives, high efficiency lighting, and other loads using switching electronics. The basics Of course, the Fluke 345 will make the basic measurements of voltage and current to determine if there is something seriously wrong with the circuit under test. It’s rated for use at the service entrance with a 600 Volt CAT IV rating. Measuring voltage is as simple as using a clamp meter: Connect the test leads up to the voltage inputs, select voltage, and then read the rms voltage. Current measurement is just as easy. Select current, open the jaw, clamp around the wire and measure. With the 2000A range and large jaw opening, you can evaluate most of the circuits in the building. The Fluke 345 can also measure both ac and dc voltage and current simultaneously, and identify the magnitude of each separately and combined as ac+dc true-rms. That’s helpful for checking a UPS, battery, and output, to make sure that the circuits are working correctly and the batteries are in good condition. A dc voltage component on the output of a UPS or even an adjustable speed motor drive may even be a quick indicator of a developing problem. For example, waveform non-symmetry will cause an apparent dc voltage component and may indicate impending failure of system output electronics. From the Fluke Digital Library @ www.fluke.com/library Download this and other application notes at www.fluke. com/library or sign up for Fluke News to get pertinent information on your industry at www.fluke.com/ subscribe LH1050 and LH1060 Power Clamp Meters Ideal combination of a clamp and power meter The LH1050/1060 ac/dc meters are essential tools for power measurement and diagnostics on switching loads such as drives and high efficiency lighting. They combine the functionality of a current clamp, power meter and harmonics meter in a single handheld instrument that has been designed to a CAT III 600 V rating. Common applications include: • Installing and testing of dc power systems • Measurement of harmonics voltage and current on industrial systems • Power and energy optimization LH1050 and LH1060 features: • Wide range of measuring tasks possible with V, A, Hz, W, VAR, VA and • • • • • • • PF in one easy to use clamp True-rms ensures correct, accurate measurement of ac+dc and distorted signals Clear presentation of results with bargraph for dual display of V/Hz, A/Hz and PF/W Flexible applications with three-phase power capability for balanced loads Easy data evaluation with ‘Smart Hold’ saving up to 7 parameters Capture trends with record mode storing Min Max and Average values EL backlight visible in varying light levels Two-year warranty Additional LH1060 features: • Check startup characteristics with measurement of peak voltage and current values Harmonic trouble shooting with measurement of Total Harmonic Distortion (THD), Distortion Factor (DF) and Crest Factor (CF) • Monitor the effects of loads with dc ripple measurement • For more information and detailed specifications, go to www.fluke.com/clamps 30 Clamp Meters Included accessories Fluke 345 Clamp Meter: Batteries, pair of measuring leads, alligator clips, operating instructions, Power Log software, interface cable pouch, and calibration certificate. LH1050/LH1060 Clamp Meters: Battery, pair of measuring leads, operating instructions, and pouch. Recommended accessories WINLOG S/W WinLOG software for LH 1050/1060, Analyst 2050/2060 Ordering information LH1050 LH1060 Fluke-345 AC/DC Power Clamp Meter AC/DC Power Clamp Meter AC/DC Power Quality Clamp Meter The LH1050 and LH1060 are not available in Canada. Fluke 360 AC Leakage Current Clamp Meter 1 μA resolution leakage current measurements with a tough, pocket sized clamp The unique jaw design of the Fluke 360 eliminates the influence of adjacent current conductors and measures leakage current down to 1 μA for monitoring of insulation. The ergonomic design of the Fluke 360 ensures easy measuring. The measuring clamp fits into tight spaces and the wide display angle clearly shows the measurement result. The data hold button keeps the measured value on the display after removing the clamp for the measured conductor. The light Fluke 360 offers the widest range of current measurement for maintenance professionals and contractors. Use the light and rugged Fluke 360 when it’s not possible to power down and break the circuit. Current measurement • Automatic ranging within the manually selected • • • • • • mA or A range Ranges 3/30 mA and 30/60 A Current resolution 1 µA/0.01 mA and 0.01 A/0.1 A Frequency range 50 and 60 Hz Jaw size: 40 mm (1.55 in) maximum conductor diameter Auto power off One-year warranty LH41 AC/DC Low Current Clamp Meter AC/DC current clamp for low current applications The compact size of the LH41 makes it ideal for making general measurements on small conductors. With excellent accuracy and resolution of 1 mA, the LH41 offers exceptional performance for automotive and other low current applications. Features • Easy use autoranging ac/dc leakage current • • • • • • • • measurements from 10 mA to 40 A High 1 mA current resolution for quick circuit comparison on sensor and control circuits Patented jaw design for high accuracy, low dc current measurement ensures no interference from other circuits Push button dc Auto Zero for correct measurement every time Battery saving auto power off function ‘Carry everywhere’ pocket size, lightweight design Convenient display hold for capturing measurement in inaccessible spots CAT III 300 V Two-year warranty LH2015 AC/DC True-rms Clamp Meter High current, large jaw clamp for industrial and utility applications The LH2015’s large jaw is suitable for current measurements up to 2000 A ac/dc on large conductors or bus bars. The LH2015’s measurement accuracy is unaffected by external magnetic fields or offcenter conductor positioning due to its advanced jaw design. Its DisplayHold feature freezes the measurement for viewing after measuring and the Max-Hold captures the maximum measured current. Current clamp measurement can be used when: • it’s not possible to power down equipment and break the circuit. • checking the current on large loads to avoid overheating of conductors. • measuring large dc currents in industrial drives. Features: • 2000 ac and dc current • • • • • measurement Accurate true-rms measurement for distorted waveforms Large 50 mm (2 in) jaw capacity Autoranging and Auto-zero Display-Hold and Max-Hold (surge) Two-year warranty Included accessories Fluke 360 Clamp Meter: Soft carrying pouch and users manual. LH41 Clamp Meter: Battery and operating instructions. LH2015 Clamp Meter: Soft case and users manual. Ordering information Fluke-360 LH41 LH2015 AC Leakage Current Clamp Meter AC and DC Current Clamp Meter AC/DC True-rms Clamp Meter These products are not available in Canada. For more information and detailed specifications, go to www.fluke.com/clamps Clamp Meters 31 Get more done with the latest Fluke tools Move up to better design and performance with Fluke clamp meters It’s never been more important to be efficient, fast, and accurate at your job. Today, you need a tool that can keep up with the demanding needs of residential, commercial, and industrial electricians. The Fluke 337 Clamp Meter provides you the ability to work quickly and easily in narrow and dark locations, and makes it possible to keep track of your measurements for further analysis. The Fluke 337 is a significant improvement from the Fluke 30 Series clamps that were built in the mid 1990’s. While the 30 Series was a leader in its day, the 337 offers a design that is compact and lightweight, and functionality that allows you to take measurements that are more precise. Fluke 330 Series clamps are designed more ergonomically with capabilities not found in their predecessors, the Fluke 30, 31, 32, 33 and 36. Specialty clamp meters See page 54 for information on the NEW! 902 True-rms HVAC Clamp Meter. See page 44 for information on the NEW! 771 Milliamp Process Clamp Meter. Function Fluke 30 Series Clamps Fluke 337 Out of warranty Three-year warranty Small body and jaws fit perfectly in your hand and into tight places — • Fits into tight areas for maximum usability Frequency measurement — • Built-in frequency counter Three-year warranty Meter controls are positioned so current measurements can be done with one hand (index finger on clamp opening lever and thumb on rotary switch) — • Large, backlit display is easy-to-see — • Inrush current function for measuring starting current for motors, lighting, etc. — • — • Max only Min/Max Improved low current measurement accuracy from new microprocessor technology Min/Max capability Benefit Lower cost of ownership Easier to use, efficient measurements Use in dark areas Easily measure inrush current on motors, switches, and circuit protectors to determine if equipment can work with high current levels More precise measurements Easily track your measurements For more information and detailed specifications, go to www.fluke.com/clamps 32 Clamp Meters Fluke 337 Premium Clamp Meter • Rugged • CAT III 600 V • Inrush • Compact Fluke 337 and 322 Clamp Meters Measure inrush motor starting current the way a circuit breaker sees it • • • • • • • • • Making accurate inrush current measurements Inrush current feature (selected models) Small body and jaws fit perfectly in your hand and into tight places Controls positioned for one hand operation Accurate low current measurements Backlight available on most models Auto shut-off Display hold Safety rating: IEC 1010-2-031, CAT III 600 V Three-year warranty on 330 Series New high-efficiency motors require better tools to evaluate and fix the consequences of their high inrush current. The Fluke 335, 336 and 337 Clamp Meters are designed to capture inrush current accurately and, most importantly, synchronously and provide readings that accurately depict what the circuit protector experiences. This application note covers practices to help you accurately and safely measure and interpret inrush current measurements. Fluke 322 Clamp Meter • Precise measurements with 1.8 % basic accuracy • Resolution up to 0.01 A and 0.1 V • Measures ac current 40.00 A/400.0 A • Measures ac and dc volts to 600 V • Resistance measurement to 400 W • Continuity for quick checking of shorts Specifications – 320 and 330 Series Fluke 320 and 330 Series Clamp Meters offer an impressive array of innovative features with current ranges up to 1000 A. Choose the model that matches the jobs you do. (@23 °C ± 5 °C RH 0 to 90 %) Fluke 321 Fluke 322 Fluke 333 Range to 400.0 A 40.00 A/ 400.0 A to 400.0 A AC current Accuracy 1.8 % + 5 counts (50 to 60 Hz) AC response Fluke 334 Range DC current Accuracy — — — — — — — — 400.0 V/600.0 V Accuracy 1.2 % + 5 counts (50 to 400 Hz) AC response Ohms 100 mS 0 to 600.0 A — — — Accuracy — 2 % + 3 counts 1 % + 5 counts (50/60 Hz) 1 % + 5 counts (20 to 100 Hz) True-rms 400.0 V/ 600 V to 600.0 W 600.0 W/6000 W 1 % + 5 counts 1.5 % + 5 counts < 30 W Continuity Range — — — — — — to 400 Hz Accuracy — — — — — — 0.5 % + 5 counts MIN/MAX — — — — — — Yes Backlight — — — Hz HxWxD Size Yes Yes Display hold 7.5 in x 2.5 in x 1.4 in 9.4 in x 3.1 in x 1.6 in 9.9 in x 3.1 in x 1.6 in Max wire dia. 1 in 1.2 in Weight 8 oz 11 oz Want to read more? Download this and other application notes at www.fluke.com/library Models 333, 334, 335, 336 and 337 Operating temperature: -10 °C to 50 °C (-14 °F to 122 °F) Altitude: 2,500 meters Battery life: (2) AA alkaline approximately 150 hours continuous, automatic low battery indicator Safety rating: IEC 1010-2-031, CAT III 600 V Temperature de-rating: Add 0.1 x specified accuracy for each ºC above 28 ºC or below 18 ºC Storage temperature: -40 ºC to 60 ºC (-40 ºF to 140 ºF) Models 321 and 322 to 600.0 V 1 % + 5 counts to 400.0 W Range 0 to 999.9 A to 600.0 V Averaging Range Accuracy to 999.9 A True-rms — Range Fluke 337 2 % + 5 counts (10 to 100 Hz) Averaging — DC volts Fluke 336 to 600.0 A — AC volts Fluke 335 2 % + 5 counts (50 to 60 Hz) Inrush Integration time Application note, literature code 2041766: Operating temperature: -10 °C to 50 °C (-14 °F to 122 °F) Altitude: 2,000 meters Battery life: (2) AAA carbon zinc approximately 100 hours continuous, automatic low battery indicator Safety rating: IEC 1010-2-031, CAT III 600 V Temperature de-rating: < 18 °C, > 28 °C add 0.1 x specified accuracy /°C Storage temperature: -30 °C to 60 °C (-22 °F to 140 °F) See page 54 for information on the NEW! 902 True-rms HVAC Clamp Meter Recommended accessories – 320 and 330 Series Included accessories Soft carrying case, test leads, (2) batteries, instruction card and safety information. TL223 SureGrip™ Electrical Test Lead Set See page 61 H3 Clamp Meter Holster See page 70 LVD1 Volt Light See page 64 TL71 Premium Test Lead Set See page 62 Ordering information Fluke Fluke Fluke Fluke 321 322 333 334 Fluke 335 Fluke 336 Fluke 337 For more information and detailed specifications, go to www.fluke.com/clamps Clamp Meters 33 Fluke 1550B and 1520 MegOhmMeters Powerful troubleshooting and predictive maintenance tools The 1550B automatically calculates polarization index and dielectric absorption ratios. The 1550B features: • Standard test voltages of 250 V, 500 V, 1000 V, 2500 V and 5000 V for a wide range of equipment testing • Programmable test voltages available in 50-volt steps from 250 V to 1000 V and 100-volt steps from 1000 V to 5000 V • Automatic calculation of Dielectric Absorption Ratio (DAR) and Polarization Index (PI) with no additional setup • Easy setup saves time and effort when conducting “timed” and “ramp” test of insulation breakdown • Improved ramp function (0 V dc to 5000 V dc) for breakdown testing • Autodischarge of capacitive voltage • Measures resistances up to one teraohm • Includes improved FlukeView® Forms Software and Optical Interface cable for easier downloading to a Windows® PC Specifications – 1550B MegOhmMeter The meter’s accuracy is specified for one year after calibration at operating temperatures of 0 °C to 35 °C. For operating temperatures outside the range (-20 °C to 0 °C and 35 °C to 50 °C), add ± .25 % per °C, except on the 20 % bands add ± 1 % per °C. Insulation resistance measurement Test Voltage (dc) Range Accuracy (± reading) 250 V 200 kW to 5 GW 5 GW to 50 GW 5% 20 % 500 V 200 kW to 10 GW 10 GW to 100 GW 5% 20 % 1000 V 200 kW to 20 GW 20 GW to 200 GW 5% 20 % 2500 V 200 kW to 50 GW 50 GW to 500 GW 5% 20 % 5000 V 200 kW to 100 GW 100 GW to 1 TW 5% 20 % Accuracy (± reading) Function Range Leakage current 1 nA to 2 mA ± (5 % + 2 nA) Capacitance measurement 0.01 uF to 15.00 µF ± (15 % rdg + 0.03 µF) Live circuit indicator 30 V to 600 V ac/dc, 50/60 Hz ± (5 % + 2 V) Short circuit current: greater than 1 mA and less than 2 mA Bargraph range: 0 to 1 TΩ Insulation test voltage accuracy: -0 % to +10 % at 1 mA load current Induced ac mains current rejection: 2 mA maximum Charging rate for capacitive load: 5 seconds per µF Timer: 0 to 99 minutes; settable in 1 minute increments; indicated to within 1 second Ramp: 0 % to 100 % of selected test voltage, or until breakdown Dimensions (HxWxL): 330 mm x 242 mm x 170 mm (13 in x 9.5 in x 6.7 in) Weight (with battery): 4 kg (8.8 lb) Battery type: 12 V, lead-acid, rechargeable Charger input (ac): 85 to 250 V ac, 50/60 Hz, 50 VA Operating temperature: -20 ºC to 50 ºC (-4 ºF to 122 ºF) Storage temperature: -20 ºC to 65 ºC (-4 ºF to 149 ºF) Relative humidity: 80 % at 31 °C decreasing linearly to 50 % at 50 °C Operating altitude: 0 to 2000 meters Enclosure sealing: IP 40 Safety conformance: EN 61010-1, CAT III, 600 V, EN61557, Parts 1 & 2 Input overload protection: 600 V ac continuous Warranty: Two-years Software: FlukeView® Forms Basic Software requires a PC running Windows® 95, 98, Me, 2000, NT4.0 FVF-UG TL1550EXT FlukeView Forms 25 Foot Extension Software Upgrade Test Lead Set See page 65 Fluke 1550B MegOhmMeter: Test leads, 5000 V-rated probes, alligator clips, interface adapter and cable, FlukeView Forms software, line cord, soft carrying case, and users manual. Fluke 1520 MegOhmMeter: TL27 Heavy Duty Test Leads, TP74 Lantern Tip Test Probes, AC285 Large Jaw Alligator Clips, protective holster with hand strap, carrying case with accessory storage, four C-cell alkaline batteries, instruction manual, and instruction manual on CD-ROM. L206 Deluxe LED Hat Light See page 64 Recommended accessories – 1520 MegOhmMeter TL27 ToolPak™ SH100 Heavy-Duty Meter Hanger Shoulder harness Test Lead Set See page 71 for 1520 See page 62 TL223 SureGrip™ Electrical Test Lead Set See page 61 C43 Soft Carrying Case See page 70 For more information and detailed specifications, go to www.fluke.com/1550 34 Insulation Resistance Testing A proven workhorse, the 1520 can make up to 5,000 insulation resistance tests, more than any other Fluke insulation tester, without changing batteries. A dual analog/digital display makes it easy to use. A lo-ohms function measures voltage and checks connections. Thanks to superb accuracy, endurance, and handheld size, the 1520 is a long-standing tool of choice for demanding plant and utilities work. • Large, backlit LCD with analog bar graph and digital display • Three output voltages for insulation resistance testing: 250 V, 500 V and 1000 V • Perform up to 5,000 insulation resistance tests without changing batteries • Insulation resistance testing up to 4000 MW; switches automatically to voltage measurement when voltage is greater than 30 V ac or 30 V dc • Auto-discharge of capacitive voltage • AC/DC voltage measurement up to 600 V • Lo-Ohms function for testing connections • Last reading memory display Included accessories Recommended accessories – 1550B MegOhmMeter Fluke 1520 MegOhmMeter Ordering information Fluke-1520 MegOhmMeter Fluke-1550B MegOhmMeter Fluke 1587 and 1577 Insulation Multimeters Two powerful tools in one The Fluke 1587 and 1577 Insulation Multimeters combine a digital 1 kV insulation tester with a full-featured, true-rms digital multimeter in a single compact, handheld unit, which provides maximum versatility for both troubleshooting and preventative maintenance. Whether you work on motors, generators, cables, or switchgear, the Fluke 1587 and 1577 Insulation Multimeters are ideally suited to help you with your tasks. • Insulation test (1587: 0.01 MW to 2 GW) (1577: 0.1 MW to 600 MW) • Insulation test voltages (1587: 50 V, 100 V, 250 V, 500 V, 1000 V), (1577: 500 V, 1000 V) for many applications • Live circuit detection prevents insulation test if voltage > 30 V is detected for added user protection • Auto-discharge of capacitive voltage for added user protection • Filter for motor drive measurements (1587 only) • AC/DC voltage, dc milliVolts, ac/dc milliamps, resistance (W), and continuity • Capacitance, diode test, temperature, Min/Max, and frequency (Hz) (1587 only) • Auto power off to save battery power • Large display with backlight and large digits • Included accessories: Remote probe, test leads and probes, alligator clips, (K-type thermocouple, 1587 only) • Accepts optional Fluke TPAK™ magnetic hanging system to free your hands for other work • Rugged, utility hard case allows you to bring everything you need for the job • Three-year warranty Get the most value and productivity from Fluke kits Establishing a preventive maintenance program is becoming critical to maintaining the uptime of electrical equipment and can significantly reduce both planned and unplanned downtime. Unplanned downtime costs are difficult to calculate, but are often significant. For some industries, it can represent 1 % to 3 % of revenue (potentially 30 % to 40 % of profits) annually. These kits can help you be proactive and efficient with your maintenance and can save you up to 10 % off the individual price of the tools. Fluke 1587/ET Advanced Electrical Troubleshooting Kit includes: • • • Fluke 1587 Insulation Multimeter Fluke i400 Current Clamp Fluke 62 Mini Infrared Themometer Fluke 1587/MDT Advanced Motor and Drive Troubleshooting Kit includes: Specifications 1587 Insulation test voltages 50 V, 100 V, 250 V, 500 V, 1000 V Insulation test voltages 500 V, 1000 V Insulation test: 0.01 MW to 2.0 GW 1577 • • • Insulation test: 0.1 MW to 600 MW • Auto-discharge of capacitive voltage • Insulation test smoothing reading • Frequency • Capacitance • Diode test • Temperature • Min/Max • Low-pass filter (for work on VSDs) • AC/DC Voltage • • DC Millivolts • • AC/DC milliAmps • • Resistance (0.1 W to 50 MW) • • Continuity • • Three-year warranty • • Remote probe, test leads, alligator clips • • K-type thermocouple • Rugged, utility hard case • • Auto power off • • • • • • Fluke 1587 Insulation Multimeter Fluke i400 Current Clamp Fluke 9040 Phase Rotation Indicator Included accessories Remote probe, test leads, alligator clips, K-type thermocouple (1587 only), hard case and user documentation. Ordering information Recommended accessories ToolPak™ Meter Hanger See page 71 i400s AC Current Clamp See page 66 C25 Meter Case See page 70 For more information and detailed specifications, go to www.fluke.com/1587 Fluke-1577 Insulation Multimeter Fluke-1587 Insulation Multimeter Fluke-1587/ET Advanced Electrical Troubleshooting Kit Fluke-1587/MDT Advanced Motor and Drive Troubleshooting Kit Insulation Resistance Testing 35 Fluke 1507 and 1503 Insulation Testers Insulation resistance testing in the palm of your hand Application note, literature code 1579160: Insulation resistance testing The Fluke 1507 and 1503 Insulation Testers are compact, rugged, reliable, and easy to use. With their multiple test voltages, they are ideal for many troubleshooting, commissioning, and preventive maintenance applications. Additional features, like the remote probe on these tools save both time and money when performing tests. Insulation test ranges: • 1507: 0.01 MW to 10 GW • 1503: 0.1 MW to 2 GW Insulation test voltages: • 1507: 50 V, 100 V, 250 V, 500 V, 1000 V • 1503: 500 V, 1000 V • Save both time and money with automatic calculation • • • • • • • • • • • • • • of Polarization Index and Dielectric Absorption Ratio (1507 only) Make repetitive tests simple and easy with the 1507’s compare (Pass/Fail) function (only available on the 1507) Repetitive or hard-to-reach testing is easy with the remote test probe Live circuit detection prevents insulation test if voltage > 30 V is detected for added user protection Auto-discharge of capacitive voltage for added user protection AC/DC voltage: 0.1 V to 600 V Lo-Ohms/Earth bond continuity (200 mA) Resistance: 0.01 W to 20.00 KW Save battery power with auto-power off Read measurements easily with large, backlit display CAT IV 600 V overvoltage category rating for added user protection Remote probe, test leads, probes, and alligator clips included with each tester Accepts optional Fluke ToolPak™ magnetic hanging system to free your hands for other work Four AA alkaline batteries (NEDA 15 A or IEC LR6) for at least 1000 insulation tests One-year warranty Insulation resistance testers can be used to determine the integrity of windings or cables in motors, transformers, switchgear, and electrical installations. The test method is determined by the type of equipment being tested and the reason for testing. For instance, when testing electrical cabling or switchgear (low-capacitance equipment) the time-dependent capacitive leakage and absorption leakage currents become insignificant and decrease to zero almost instantly. A steady conductive leakage current flow is reached almost instantly (a minute or less) providing perfect conditions for the spot-reading/short time resistance test. Want to read more? Download this and other application notes at www.fluke.com/library, or sign up for Fluke News for pertinent information on your industry at www.fluke.com/subscribe Features – 1507 and 1503 Testers Feature 1507 Insulation test voltages 50 V, 100 V, 250 V, 500 V, 1000 V 1503 • Insulation test voltages 500 V and 1000 V • • Insulation test: 0.01 MW to 10 GW • Insulation test: 0.01 MW to 2 GW PI/DAR • Auto discharge of capacitive voltage • • Remote test probe, test leads, alligator clips • • Rugged utility hard case • • Auto power off • • Recommended accessories – 1507 and 1503 Testers Included accessories Remote probe, test leads, test probes, alligator clips, holster and user documentation. C101 Meter Hard Case See page 70 ToolPak™ Meter Hanger See page 71 C25 Meter Case See page 70 For more information and detailed specifications, go to www.fluke.com/1507 36 Insulation Resistance Testing Ordering information Fluke-1507 Fluke-1503 Insulation Tester Insulation Tester Pick the right process tool for you Process Tools Selection Guide Model Loop Calibrator Pressure Calibrator Temperature Calibrator Precision Multifunction Process Calibrator Intrinsically Safe Calibrator Documenting Process Calibrator Process mA Clamp Meter ProcessMeter® Test Tool 715 718 724 726 725Ex 744 771 789 30 V 30 V 30 V 300 V 1000 V 300 V 1000 V Measure V dc 25 V V ac (true-rms) Resistance A dc 24 mA 24 mA 3200 W 4000 W 3200 W 11 kW 24 mA 24 mA 24 mA 110 mA 15 kHz 10 kHz 50 kHz •1 •5 •1 40 MW 20.99, 99.9 mA A ac 30 mA, 1 A • Frequency 1 psi, 30 psi, 100 psi and 300 psi Pressure Temperature: RTDs 7 types 8 types 7 types 8 types Temperature: TCs 12 types 13 types 12 types 13 types 20 kHz Source/Simulate V dc 20 V 10 V 20 V 10 V 15 V 3200 W 4000 W 3200 W 11 kW 24 mA 24 mA 24 mA 22 mA 24 mA • • • • • Resistance mA dc/% scale mA source; auto step, auto ramp Frequency 15 kHz 10 kHz 50 kHz Temperature: RTDs 7 types 8 types 7 types 8 types Temperature: TCs 12 types 13 types 12 types 13 types Record Min/Max • • Hold • • As Found/As Left results • Log data • Upload data to PC • • • • Remote operation • • Features 24 V loop supply • • • • 12 V • • Non-contact measurement • Hart communication • Integrated hand pressure pump • Intrinsically safe (ATEX) Warranty • 3 years 1 year 3 years 3 years 1 year 3 years NIST traceable certification • • • • • • Accessories3 A/B C A/B A/B • • • 39 45 38 Pressure enabled4 See page • 42 41 40 1 year 3 years A/B 44 43 1Fluke 700 Pressure Modules required. the internal sensor or a Fluke 700 Pressure Module may be used. 3Accessories: A. Compatible with LockPak B. Compatible with ToolPak C. Accepts hanging straps from ToolPak D. Optional accessories 4Fluke Process Calibrators in this guide displaying the Pressure Enabled symbol display readings from the 700 Series Pressure Modules. 5Fluke 700PEx Pressure Module required. 2Either Process Calibration Tools 37 Fluke 741B, 743B and 744 Calibrators For the calibration and troubleshooting of process control instrumentation • • • • • • • • • • • Calibrate temperature, pressure, voltage, current, resistance and frequency instruments Built-in procedures for transmitters, square root transmitters, pressure and temperature switches Simultaneously measure and source Automatically capture calibration results Document procedures and results to meet ISO 9000, EPA, FDA, OSHA, and other government requirements Measure/simulate 13 types of thermocouples and eight RTDs Store up to 8,000 readings in data logging mode (743B and 744 only) Protected against dirt, dust and moisture; unaffected by vibration Includes a PC interface (743B and 744 only) Operate in English, French, German, Italian and Spanish Offer one- and two-year calibration cycles and a three-year warranty (one-year for pressure modules) Pressure Enabled Application note, literature code 1262439: HART® transmitter calibration The need for calibration of HART smart transmitters is often misunderstood. What do you calibrate and when? Here is a step-by-step procedure showing how to use the Fluke 744 to perform calibration and digital adjustments of Rosemount 3051 and 3144 transmitters and other HART devices. 744: Get HART-ability The Fluke 744 offers all of the capabilities of the 743B, plus the ability to calibrate, maintain, and troubleshoot HART instrumentation. Integrated HART communication functions permit you to monitor, control, and calibrate HART instrumentation. It handles fast pulsed instruments such as RTD transmitters and PLCs, with pulses as short as 1 ms. See www.fluke.com/744upgrade for the latest list of HART instruments. 741B: A complete documenting calibrator The 741B is the economical choice for plants that don’t use PCs or that require traditional paper forms. It has storage capacity for a day’s calibration and measurement data. When you’re back at the shop, recall the data on-screen to fill out calibration forms. 743B: More memory, plus a PC interface and data logging The 743B has all the capabilities of the 741B plus a PC interface that lets you load procedures, lists, and instructions created with software—or unload data for printing, archiving, and analysis. With its expanded memory, the 743B can hold a full week of calibrations and procedures. Specifications – 741B, 743B and 744 Function Measure Sourcing DC voltage 0.025 % reading + 0.005 % full scale 0.01 % output + 0.005 % full scale DC current 0.01 % reading + 0.015 % full scale 0.01 % output + 0.015 % full scale Resistance 0.05 % reading + 50 mΩ 0.01 % output + 40 mΩ Frequency 0.05 % 0.01 % Thermocouples 0.3 °C 0.2 °C RTDs 0.3 °C 0.1 °C Pressure To 0.25 % of full scale, per pressure module specifications. Summary specifications: best case, midrange, one-year. Battery life: Typically over eight hours Internal battery pack: NiCd, 7.2 V, 1700 mAh, NiMH 3500 mAh on 744. Battery replacement: Via snap-shut door without opening calibrator; no tools required Weight: 1.4 kg (3 lb 1 oz) Size (HxWxD): 236 mm x 130 mm x 61 mm (9.3 in x 5.1 in x 2.4 in) Instrumentation management software The Fluke 743B and 744 are compatible with Fluke 700SW DPC/TRACK software and with software from Beamex, Cornerstone, Emerson, Honeywell, On Time Support, Prime Technologies, Yokogowa, Intools and Meridium. For more information, visit www.fluke.com/software Included accessories TL224 Industrial Test Leads (2 sets), AC220 Test Clips (2 sets), TP220 Test Probes, BP7217 Battery Pack, BC7217 Battery Charger, instruction manual, NIST Traceable calibration certificate and data, serial port cable (743B and 744 only), DPC/TRACK sample version with free PC communication utility software (743B and 744 only). Additional 744 accessories BP7235 NiMH Battery Pack, HART communications cable, HART user’s manual and NIST Traceable calibration certificate and data. Ordering information Recommended accessories – 741B, 743B and 744 C789 Meter and Accessory Case See page 70 Fluke-700PTP Fluke-700Pxx Pneumatic Pressure Modules Test Pump See page 41 See page 69 80PK-25 SureGrip Piercing Temperature Probe See page 68 For more information and detailed specifications, go to www.fluke.com/740 38 Process Calibration Tools TL220 SureGrip Industrial Test Lead Set See page 61 Fluke-741B Fluke-743B Fluke-744 Fluke-700S Documenting Process Calibrator Documenting Process Calibrator Documenting Process Calibrator DPC/Track Software Fluke 726 and 725 Multifunction Process Calibrators Step up to unmatched accuracy in process measurement and calibration Fluke 725 Multifunction Process Calibrator • Measure volts, mA, RTDs, Pressure Enabled Fluke 726 Precision Multifunction Process Calibrator The Fluke 726 Precision Multifunction Process Calibrator is designed specifically for the Process industry with broad workload coverage, calibration power and unsurpassed accuracy in mind. The 726 measures and sources almost all process parameters and can calibrate almost anything. The 726 will also interpret results without the help of a calculator and store measurement data for later analysis. • • • • • • • • • Precise measurement and calibration source performance, accuracies of 0.01 % Transmitter error% calculation, interpret calibration results without a calculator Memory storage for up to 8 calibration results, return stored calibration data from the field for later analysis Frequency totalizer and frequency pulse train source mode for enhanced flowmeter testing HART mode inserts 250 ohm resistor in mA measure and source for compatibility with HART instrumentation Integrated pressure switch test allows you to capture the set, reset and deadband of a switch Custom RTD curves, add calibration constants for certified RTD probes for enhanced temperature measurement New voltage input protection design for improved reliability Three-year warranty • • • • • thermocouples, frequency and ohms to test sensors and transmitters Source/simulate volts, mA, thermocouples, RTDs, frequency, ohms and pressure to calibrate transmitters Measure/source pressure using any of 29 Fluke 700Pxx Pressure Modules Source mA with simultaneous pressure measurement to conduct valve and I/P tests Support flow meter testing with frequency and counts per minute (CPM) functions Perform fast linearity tests with auto step and auto ramp features Intrinsically safe version available (see page 45) Specifications – 726 and 725 Calibrators Simultaneous function capability Channel A Channel B 24.000 mA dc M M or S Measure and source 24.000 mA dc with 24 V loop supply M Function Range or type Resolution Accuracy Notes Voltage 0 to 100 mV 0 to 10 V (source) 0 to 20 V (source) 0 to 30 V (measure) 0.01 mV 0.01 V 0.01 V 0.01 V 0.01 %, 0.02 % Rdg + 2 LSD Max load, 1 mA mA 0 to 24 0.001 mA 0.01 %, 0.02 % Rdg + 2 LSD Max load, 1000 W mV (TC terminals) -10.00 mV to +75.00 mV .01 mV 0.01 %, 0.02 % of range + 1 LSD Ohms 15 W to 3,200 W 5 W to 4,000 W 0.01 W to 0.1 W 0.10 W to 1.0 W 0.015 % Hz - CPM 2.0 to 1,000 CPM 1 to 1000 Hz 1.0 to 10.0 kHz 10.0 to 15.0 kHz 0.1 CPM 1 Hz 0.1 kHz 0.1 kHz ± 0.05 % ± 0.05 % ± 0.25 % ± 0.05 % Loop supply 24 V dc N/A 10 % T/C J, K, T, E, L, N, U, XK 0.1 °C, 0.1 °F to 0.7 °C to 0.2 °C T/C B, R, S, BP 1 °C, 1 °F to 1.7 °C to 1.2 °C RTDs Cu (10), Ni120 (672) Pt 100, 200, 500, 1000 (385) Pt 100 (3916), Pt 100 (3926) 0.01 °C, 0.01 °F to 0.15 °C 0.1 °C, 0.1 °F to 0.2 °C Source; 5 V p-p 1 V to 20 V p-p squarewave, -0.1 V offset General specifications Storage temperature: -20 °C to 71 °C Operating temperature: -10 °C to 55 °C Relative humidity: 90 % (10 °C to 30 °C); 75 % (30 °C to 40 °C); 45 % (40 °C to 50 °C); 35 % (50 °C to 55 °C) Shock: 1 meter drop test Safety: CSA C22.2 No. 1010.1:1992 EMC: EN50082-1:1992 and EN55022:1994 Class B Size (HxWxD): 200 mm x 96 mm x 47 mm (7.9 in x 3.8 in x 1.9 in) Weight: 650 g (23 oz) Battery: Four AA alkaline batteries Battery life: 25 hours typical Unique 726 specifications are bolded Recommended accessories – 726 and 725 Calibrators Fluke-700PTP C125 ToolPak 80PK-27 Pneumatic Meter Case Meter Hanging Kit SureGrip Industrial Surface Temperature Probe Test Pump See page 70 See page 71 See page 69 See page 68 100.00 mV dc 30.000 V dc measure M or S M 20.000 V dc measure 10.000 V dc source 20.000 V dc source M or S 15 to 3200 Ohms 5 to 4000 Ohms M or S Thermocouple J, K, T, E, R, S, B, M, L, U, N, XK, BP M or S RTD Cu 10, Ni120; Pt100 (392); Pt100 (JIS); Pt100, 200, 500, 1000 (385), XK and BP M or S Pressure (requires Fluke 700PXX Modules) M M used as S Frequency; 10 kHz; (15 KHz 726) M or S M = Measure, S = Source/Simulate Included accessories TL75 Test Leads, AC72 Test Clips, one pair of stackable test leads, product overview manual (print) and users manual in 14 languages on CD-ROM. Ordering information Fluke-726 Precision Multifunction Process Calibrator Fluke-725 Multifunction Process Calibrator Fluke-724 Temperature Calibrator (also see page 40) For more information and detailed specifications, go to www.fluke.com/726 Process Calibration Tools 39 Fluke 712, 714 and 724 Temperature Calibrators Accurate and rugged, temperature calibration tools  ata Sheet, literature code D 1560369: Temperature calibration The Fluke 710 Series temperature calibrators deliver outstanding performance, durability and reliability. And with a push-button interface, similar to the multifunction Fluke 740 Series Documenting Process Calibrators, the 710s are easy to use. Each calibrator is EMI tolerant, dust- and splash-resistant, and features a removable battery door for quick battery changes. See how Fluke can help you calibrate, troubleshoot and verify the most common temperature devices, faster and easier. Fluke 712 RTD Calibrator • Compatible with pulsed current transmitters • Measure temperature from an RTD probe • Simulate RTD output • Operates with seven types of RTD • Measure additional RTDs using Ohms measurement • • • • function Simulate additional RTDs using Ohms source function °F or °C selectable 25 % stepping, auto-step and auto-ramp Ramp and Step Ramp output functions Fluke 714 Thermocouple Calibrator • Measure temperature from TC probes • Simulate TC output • Operable with nine types of thermocouples • Calibrate linear TC transmitter with mV source function • Selectable °F or °C • 25 % stepping, auto-step and auto-ramp • Available as accessories: Fluke 700TC1 and TC2 • Want to read more? Download this and other application notes at www.fluke.com/library Fluke 724 Temperature Calibrator • Source/measure TCs, RTDs, volts and ohms Measure mA while supplying loop power • 25 % and 100 % stepping, auto-step and auto ramp • Thermocouple Mini-plug Kits Ramp and Step Ramp output functions Specifications – 712 and 714 Calibrators Model Function Range Resolution Accuracy Notes Fluke-712 Measure/simulate RTD -200 °C to 800 °C (Pt 100-385) 0.1 °C, 0.1 °F 0.2 °C, 0.4 °F (Pt 100-385) Pt; 100 200 500 1000 (385); Pt 100 (392); Pt 100 (392) JIS; Ni 120 (672) Measure/simulate resistance 5 W to 4000 W 0.1 W 0.025 % Measure/simulate thermocouple -200 °C to 1800 °C, depending on type (K, -200 °C to 1370 °C) 0.1 °C or °F (1 °C or °F; BRS) 0.5 °C, 0.8 °F (Type K) Measure/simulate mV -10 mV to 75 mV 0.01 mV 0.015 % +10 µV Fluke-714 9 TC types; J K T E R S B per NIST 175 and ITS-90 L U per DIN 43710 and PTS-68 General specifications for all Fluke 712 through 718 calibrators Maximum voltage: 30 V Non-operating temperature: -40 °C to 60 °C Operating temperature: -10 °C to 55 °C Relative humidity: 95 % (10 °C to 30 °C); 75 % (30 °C to 40 °C); 45 % (40 °C to 50 °C); 35 % (50 °C to 55 °C) Operating altitude: 3,000 m max Shock: 1 m drop test Vibration: Random, 2 g, 5-500 Hz Safety: CSA C22.2 No. 1010.1:1992 EMC: EN50082-1:1992 and EN55022:1994 Class B Size/weight (HxWxD) (712-717): 187 mm x 87 mm x 32 mm (7.35 in x 3.41 in x 1.25 in) 330 g (12 oz) Size/weight (HxWxD) (712-717 with holster): 201 mm x 98 mm x 52 mm (7.93 in x 3.86 in x 2.06 in) 600 g (21 oz) Size/weight (HxWxD) (718): 210 mm x 83 mm x 62 mm (8.25 in x 3.27 in x 2.44 in) 737 g (26 oz) Size/weight (HxWxD) (718 with holster): 216 mm x 94 mm x 66 mm (8.50 in x 3.72 in x 2.60 in) 992 g (35 oz) Power: 9 V battery ANSI/NEDA 1604A or IEC 6LR619V alkaline; two batteries in 718 Battery life: 4 to 20 hours, typical, depending on functions used Warranty: Three-years (one-year on pressure pump in Fluke 718) TL75 (712 and 724) C550 Hard Point Tool Bag Test Lead Set See page 70 See page 62 TL220 (712 and 724) C25 (712 and 714) SureGrip Industrial Large Soft Case Test Lead Set See page 70 See page 61 Included accessories Each 71X calibrator includes: Protective yellow holster with test lead storage, test leads and alligator clips (excluding model 714), single 9 V alkaline battery and instruction sheet (14 languages). Recommended accessories – 712, 714 and 724 Calibrators 80PK-24 (714) SureGrip Air Temperature Probe See page 68 Fluke 724: TL75 Test Leads, AC72 Test Clips, one pair of stackable test leads, product overview manual (print) and users manual in 14 languages on CD-ROM. Ordering information C101 (724) Meter Hard Case See page 70 80PK-3A (714, 724) Surface Probe See page 68 ToolPak Meter Hanging Kit See page 71 For more information and detailed specifications, go to www.fluke.com/tempcal 40 Process Calibration Tools Fluke-712 RTD Calibrator Fluke-714 Themocouple Calibrator Fluke-724 Temperature Calibrator Fluke 718 and 717 Pressure Calibrators Pressure Enabled Compact, professional, pressure calibration tools Application note, literature code 2577485: Pressure calibration with the Fluke 718 Fluke 718 Pressure Calibrators New design protects on-board pump from fluid damage. This application note explains how to drain pressure lines safely before calibration, and how to clean the pressure pump on the new Fluke 718. New! 1 psi and 300 psi models in addition to the 30 and 100 psi models previously available • Compact size, lightweight • New built-in pressure switch test feature • Built-in pressure/vacuum hand pump, with vernier • • • • • and bleed valve Pressure and vacuum measurement to 0.05 % of full span, using an internal pressure sensor (dry air only) Pressure measurement to 10,000 psi/700 bar using any of 29 Fluke 700Pxx Pressure Modules Measure mA with 0.015 % accuracy and 0.001 mA resolution, while providing 24 volt loop power supply 1⁄8 inch NPT female pressure fitting Min/Max/Hold functions 0RESSURECALIBRATION WITHTHE&LUKE .EWDESIGNPROTECTSON BOARD PUMPFROMFLUIDDAMAGE !PPLICATION.OTE 0ROTECTYOURTOOLS 0RESSURECALIBRATIONTYPICALLY INVOLVESAPNEUMATICCALIBRATION PUMPANDAPRESSURECALIBRA TIONTOOLORREFERENCEGAUGE4HE PUMPAPPLIESPRESSURETOBOTH THEDEVICEUNDERTEST$54 AND 6 THECALIBRATIONTOOLSEEFIGURE  4HETRICKISTHATBEFOREYOU 6 CANAPPLYPRESSUREWITHAPNEU MATICHANDPUMP YOUABSOLUTELY MUSTFIRSTDRAINALLCONDENSATE ANDOILFROMTHELINES7HY)F THERESOILORWATERTRAPPEDIN THELINEWHENTHEPUMPISCON 2ED NECTED THATFLUIDCANBEPULLED BACKINTOTHEPUMPWHENTHE PRESSUREISRELEASED4HATCAN "LACK EITHERCAUSECOSTLYDAMAGETOTHE PUMP ORATTHEVERYLEASTFORCE YOUTODISASSEMBLEANDCLEANTHE PUMPBEFORERE USE &IGURE4ODRAINPROCESSmUIDS CLOSE6ANDOPEN6BEFORECONNECTINGTHE#ALIBRATOR &ORTHISREASON THEUPDATED &LUKE0RESSURE#ALIBRA THECOMPLEXITYANDCOSTOFREPAIR ENTERINGTHEPUMPANDCAUSING TORNOWCONTAINSANINNOVATIVE OFAPUMPFOULEDBYPROCESS DAMAGE4HESETWOCHECKVALVES NEWPUMPDESIGNTHATISEASILY MEDIAISNORMALLYHIGHERTHANA ALLOWTHEBI DIRECTIONALFLOWOF CLEANEDINTHEFIELDANDINHIBITS STANDALONEPUMP AIRINTOOROUTOFTHE DAMAGEFROMPROCESSFLUIDS %VENAFTERDRAININGTHEPRO 5SINGTHEUPDATED #ALIBRATORPUMP 0NEUMATICPRESSURE CALIBRATORSWITH INTEGRATEDTESTPUMPS )NSTEADOFTHEPUMP PLUS CALIBRATORMETHODDESCRIBED ABOVE MANYTECHNICIANSNOW USEAHANDHELDPNEUMATICPRES SURECALIBRATORTHATINCLUDESAN ONBOARDPNEUMATICPUMP MAR RYINGTWODEVICESINTOONEHANDY INTEGRATEDTOOL7HILETHEINTE GRATEDPUMPISMORECONVENIENT ANDEASIERTOUSE ITISDOUBLY IMPORTANTTOMAKESUREPROCESS FLUIDSAREPROPERLYDRAINEDBEFORE MAKINGACONNECTION"ECAUSE THEPUMPITSELFNORMALLYNEEDS TOBEREMOVEDFROMTHECALIBRA TORBEFORECLEANING REBUILDINGOR REPLACEMENTCANBEPERFORMED CESSFLUIDFROMTHECALIBRATION PORTOFTHEDEVICEUNDERTEST MINUTEAMOUNTSOFPROCESS 4HENEW&LUKEISAUNIQUELY FLUIDSMAYOFTENSTILLBELURKING PROTECTEDPNEUMATICPRESSURE BEHIND)NTHEEVENTTHESEFLUIDS CALIBRATORANDPUMP4HENEW ENTERTHEPUMPCAVITIES THE PUMPDESIGNUSESPROTECTIVE NEWPUMPDESIGNENABLESQUICK CHECKVALVESTHATALLOWAIRTO CLEANINGANDMAINTENANCE EVEN PASSTHROUGHTHEPUMPFORCALI INTHEFIELD BRATIONBUTINHIBITSFLUIDSFROM !IRFLOWTO INPUT CONNECTOR ANDVERNIER ADJUSTMENT )NLET /UTLET 4OPUMP &IGURE4HE&LUKEISDESIGNEDTOPROTECTTHEHANDPUMPANDSIMPLIFYMAINTENANCE Àœ“Ê̅iʏՎiÊ ˆ}ˆÌ>ÊˆLÀ>ÀÞÊJÊÜÜÜ°vÕŽi°Vœ“ɏˆLÀ>ÀÞ Want to read more? Download this and other application notes at www.fluke.com/library Intrinsically safe 718 version available (see page 45) Fluke 717 Pressure Calibrators Now with 9 ranges: 1, 30, 100, 300, 500, 1000, 1500, 3000 and 5000 psi • Measure pressure and vacuum to 0.05 % of full scale with internal 30 or 100 psig sensor – 1/8 NPT pressure fitting – Compatible with non-corrosive gasses and liquids • Measure pressure to 10,000 psi/69 mPa using one of 29 Fluke 70Pxx Pressure Modules • Measure mA with 0.015 % accuracy and 0.001 mA resolution, while providing 24 V loop power • New built-in pressure switch test feature • Min/Max/Hold functions Pressure Enabled Fluke Process Calibrators in this catalog displaying the Pressure Enabled symbol display readings from the 700 Series Pressure Modules. Fluke 700 Series Pressure Modules • 29 pressure modules • 8 intrinsically safe pressure modules* • Ranges from 1.000 in H 0 2 Specifications – 717 and 718 Calibrators • • (0.2491 kPa) to 10,000 psi (68.948 MPa) Gage, differential, dual (compound), absolute, and vacuum modules Rugged cases protect the modules from harsh environments Full-accuracy performance from 0 °C to 50 °C Pressure readings update twice per second, and may be displayed in up to 11 different units One-year warranty Range Resolution Comment +/- 1 psi, 27.5 in H20, (-7 - +7 kPa) +0.0001 psi, 0.0001 kPa, 0.0001 in H20 Fluke-718 dry air only and includes on board pump -12 to + 30 psi, (-83 to 207 kPa) 0.001 psi, 0.001 kPa, 0.001 in H20 Fluke-718 dry air only and includes on board pump -12 to + 100 psi, (-83 to 690 kPa) 0.01 psi, 0.01 kPa, 0.01 in H20 Fluke-718 dry air only and includes on board pump -12 to +300 psi, (-83 to +2070 kPa) 0.01 psi, 0.01 kPa, 0.01 in H20 718-300G Fluke-718 dry air only and includes on board pump • 717-500G 0-500 psi, 0-3450 kPa 0.01 psi, 0.1 kPa Compatible with non-corrosive gases and fluids *for use with 718Ex and 725Ex only (see page 45 for more information) 717-1000G 0-1000 psi, 0-6900 kPa 0.01 psi, 0.1 kPa Compatible with non-corrosive gases and fluids 717-1500G 0-1500 psi, 0-10342 kPa 0.1 psi, 1 kPa Compatible with non-corrosive gases and fluids 717-3000G 0-3000 psi, 0-20700 kPa 0.1 psi, 1 kPa Compatible with non-corrosive gases and fluids 717-5000G 0-5000 psi, 0-34500 kPa 0.1 psi, 1 kPa Compatible with non-corrosive gases and fluids Pressure accuracy 0.05 % of range mA measurement 0-24 mA range 0.001 mA resolution Accuracy: ± 0.015 % + 1 count Loop power 24 V dc 717-1 718-1G 717-30G 718-30G 717-100G 718-100G 717-300G Accuracy: ± 10 % Recommended accessories – 717 and 718 Calibrators 700ILF In-Line Filter See page 69 700LTP Low Pressure Test Pump See page 69 TL220 C25 (717 only) SureGrip Industrial Large Soft Case Test Lead Set See page 70 See page 61 700HTP Hydraulic Test Pump See page 69 For more information and detailed specifications, go to www.fluke.com/pressure • • Included accessories Fluke 718 and 717: Protective yellow holster, test leads and alligator clips, single 9 V alkaline battery (two 9 V batteries in 718) and instructions. Ordering information Fluke-718 Fluke-718 Fluke-718 Fluke-718 Fluke-717 Fluke-717 Fluke-717 Fluke-717 Fluke-717 Fluke-717 Fluke-717 Fluke-717 Fluke-717 30US Pressure 100US Pressure 1G Pressure 300G Pressure 30G Pressure 100G Pressure 1G Pressure 300G Pressure 500G Pressure 1000G Pressure 1500G Pressure 3000G Pressure 5000G Pressure Calibrator Calibrator Calibrator Calibrator Calibrator Calibrator Calibrator Calibrator Calibrator Calibrator Calibrator Calibrator Calibrator Process Calibration Tools 41 Fluke 715, 707 and 705 Loop Calibrators Application note, literature code 1989137: Complete family of volt/mA calibrators Troubleshooting process loops Fluke 707 and 705 In process systems, problems with the loop can bring things to a screeching halt. In this application note, find out how to use Fluke test tools to identify current loop prolems such as noise, ripple and drift. Two powerful models to choose from • Innovative output adjustment dial on 707 provides • • • • • • • • • 1 µA and 100 µA resolution and one-hand operation Large display and simple interface for ease of use Simultaneous mA and % readout for quick, easy interpretation of readings mA accuracy of 0.015 % on the Fluke 707 and 0.02 % on the 705 HART™ mode on 707 connects 250 ohm resistor in series with 24 V loop for compatibility with HART communicators Push button 25 % steps for fast, easy linearity checks “Span Check” for fast confirmation of zero and span Selectable slow and fast linear step ramp provide ramping outputs for valve slewing, remote testing and loop functional tests 24 V internal loop supply, so you can power and read a transmitter at the same time without carrying a DMM 0 mA to 20 mA or 4 mA to 20 mA default start up modes Intrinsically safe 707 version available (see page 45) Fluke 715 Volt/mA Calibrator • Source voltage to 200 mV or 20 V • Measure loop current (0 to 20 mA, • • • Specifications – 715, 707 and 705 Functions • Fluke 705 and 707 4 to 20 mA) signals with 0.01 % accuracy and 1 µA resolution Measure voltage output process signals from PLCs, transmitters Source or simulate 24 mA loop current 24 V loop supply with simultaneous current measurement Ramp and Step Ramp output functions Fluke 715 Voltage measurement Range Resolution Accuracy 0 to 28 V 0 to 200 mV 0 to 25 V 1 mV 10 µV 1 mV 705: 0.025 % Rdg + 1 LSD 707, 707Ex: 0.015 % Rdg + 2 LSD 0.01 % Rdg + 2 LSD 0 to 24 mA 0 to 24 mA Current measurement Range Resolution Accuracy 0.001 mA 0.001 mA 705: 0.02 % Rdg + 2 LSD 707, 707Ex: 0.015 % Rdg + 2 LSD 0.01 % + 2 LSD Current sourcing Range 0 to 20 mA or 4 to 20 mA 0 to 20 mA or 4 to 20 mA 705: 0.025 % Rdg + 2 LSD 707, 707Ex: 0.015 % Rdg + 2 LSD 0.01 % Rdg + 2 LSD 705: 1000 W @ 24 mA 707: 1200 W @ 24 mA 707Ex: 700 W @ 20 mA 1000 W @ 24 mA 1 Accuracy Drive capability 1 Loop power while measuring mA 24 V 24 V Voltage sourcing N/A 0 to 200 mV or 0 to 20 V Display current and % of span Yes mA or % Auto step, auto ramp Yes Yes Span Check Yes Yes Battery life 18 hours typical, at 12 mA 18 hours typical, at 12 mA Will over-range to 24 mA 1 Recommended accessories – 715, 707, 707Ex and 705 Calibrators Included accessories Fluke 715: Protective yellow holster, test leads and alligator clips, single 9 V alkaline battery and instruction sheet (14 languages). Fluke 705, 707 and 707Ex: Protective holster, TL75 Test Leads, AC72 Test Clips and instruction sheet (14 languages). TL28A Heavy Duty Test Lead Set See page 62 TL220 C25 C550 SureGrip Industrial Large Soft Case Tool Bag Test Lead Set See page 70 See page 70 See page 61 For more information and detailed specifications, go to www.fluke.com/loop 42 Process Calibration Tools PV350 Pressure Vacuum Module See page 65 Ordering information Fluke-715 Fluke-707 Fluke-707Ex Fluke-705 Volt/mA Calibrator Loop Calibrator IS Loop Calibrator Loop Calibrator Fluke 789 and 787 ProcessMeter ™ Test Tools Safety rated multimeters with mA source In-field valve positioner checks Fluke 789 ProcessMeter With the Fluke 789 ProcessMeter, process technicians can do a lot more while carrying a lot less. Key Fluke 789 features: • 24 V loop power supply • HART mode setting with loop power (adds 250 ohm resistor) Double-sized, dual display 20 mA drive into 1200 ohms Backlight with two brightness settings 0 to 100 % mA Span Check buttons to toggle between 4 mA and 20 mA • Infrared I/O serial port compatible with FlukeView® Forms Software • Improved battery power with four AA batteries • Plus all the proven 787 features • • • • Fluke 787 ProcessMeter • Simultaneous mA and % of scale readout on mA output • 25 % Manual Step plus Auto Step and Auto Ramp on • • Application note, literature code 2041342: Valve positioners open and close with a 4 to 20 mA signal applied. This application note explains how to adjust these valves so they open and close correctly. Want to read more? Download this and other application notes at www.fluke.com/library mA output Min/Max/Average/Hold/Relative modes Externally accessible battery for easy changes Designed and Conforms to IEC 1010-1 600V CAT IV (Fluke 789 only) Specifications – 789 and 787 ProcessMeter Measurement function Best accuracy range and resolution V dc 400.0 mV, 4.000 V, 40.00 V, 400.0 V, 1000 V (% of reading + LSD) 0.1 % + 1 V dc (true-rms) 400.0 mV, 4.000 V, 40.00 V, 400.0 V, 1000 V 0.7 % + 2 mA dc 30.000 mA .05 % + 2 A dc 1.000 A (0.440 A continuous) 0.2 % + 2 A ac 1.000 A (0.440 A continuous) Resistance 400.0 W, 4.000 k, 40.00 k, 400.0 k, 4.0 M, 40 M Frequency (0.5 Hz to 20 kHz) 199.99 Hz, 1999.9 Hz, 19.999 kHz Diode Test 789: 2.000 V (shows diode voltage drop) 787: 2.400 V (shows diode voltage drop) Continuity Beeps for resistance < approx. 100 ohms Output function Range and resolution DC current output (Internal battery operation) 0.000 mA to 20.000 mA or 4.000 mA to 20.000 mA (selectable at power-up) Over-range to 24.000 mA 789: 24 V compliance or, 1,200 Ohms, @ 20 mA 787: 12 V compliance or, 500 Ohms, @ 20 mA .05 % DC current simulate (Ext. 24 Volt loop supply, up to 48 V on 789 only) 0.000 mA to 20.000 mA or 4.000 mA to 20.000 mA, (selectable at power-up) Over-range to 24.000 mA 1000 Ohms, @ 20 mA .05 % 24 V loop supply 789: Minimum 24 V 787: not available 250 Ohms @ 20 mA > 24 V Current adjustment modes Manual: Coarse, Fine, 25 % and 100 % step (100 % step 789 only) Automatic: slow ramp, fast ramp, 25 % step 1%+2 0.2 % + 1 .005 % + 1 2%+12%+1 Drive capability Accuracy (% of span) Temperature range of 18 °C to 28 °C, for one year after calibration Maximum voltage applied between any jack and earth ground:1000 V rms Storage temperature: -40 °C to 60 °C Operating temperature: -20 °C to 55 °C Relative humidity: 95 % up to 30 °C; 75 % up to 40 °C; 45 % up to 50 °C; 35 % up to 55 °C Safety: Designed in accordance with EN61010, ANSI/ISA S82.01-1994 and CAN/CSA C22.2 No. 1010.1-92 Over-voltage CAT III Size (HxWxL)/weight (787 with holster): 52 mm x 98 mm x 201 mm (2.06 in x 3.86 in x 7.93 in)/638 g (1.4 lb) Size (HxWxL)/weight (789): 50 mm x 100 mm x 203 mm (1.97 in x 3.94 in x 8.00 in)/600 g (1.3 lb) Recommended accessories – 787 and 789 ProcessMeter TL220 ToolPak SureGrip Industrial Meter Hanging Kit See page 71 Test Lead Set See page 61 80T-150U C125 Universal Meter Case Temperature Probe See page 70 See page 69 PV350 Pressure Vacuum Module See page 65 Included accessories Fluke-789 ProcessMeter: TL71 Premium Safety-Designed Test Lead Set plus alligator clips, 4 AA alkaline batteries (installed), product overview and users manual (CD-ROM) in 14 languages. Fluke-787 ProcessMeter: Protective yellow holster with test lead storage, TL75 Safety-Designed Test Lead Set plus alligator clips, one 9 V alkaline battery (installed), product overview and users manual (CD-ROM) in 14 languages. Ordering information Fluke-789 ProcessMeter Fluke-787 ProcessMeter For more information and detailed specifications, go to www.fluke.com/processmeters Process Calibration Tools 43 Fluke 771 Milliamp Process Clamp Meter Save time and money troubleshooting process control loops The innovative new Fluke 771 mA Process Clamp Meter is designed to measure, test, and troubleshoot 4-20 mA control signals without breaking the mA loop. Make mA measurements in active control systems without disrupting process control. Features: • Best in class 0.2 % accuracy • Resolution and sensitivity to 0.01 mA • Hold function captures and displays changing measurements • Dual display with both mA measurement and 0 % to 100 % of 4 mA to 20 mA span • Measurement spotlight illumination hard to see wires in dark enclosures • Detachable clamp with extension cable for measurements in tight locations • Includes carrying case that can be used as a belt mounted holster Key uses: • Measure mA signals for PLC and control system analog I/O • Measure 4 mA to 20 mA output signals from transmitters • Measure 10 mA to 50 mA signals in older control systems using the 99.9 mA range Detachable clamp used to measure 4 mA to 20 mA signals on transmitters without breaking the loop. Fluke 771 included accessories N10140 Carrying case, and instruction manual. Ordering information Range Resolution Accuracy Features Notes -20.99 mA to +20.99 mA 0.01 mA 0.2 % or reading Zero, Hold, backlight, + 5 counts measurement spotlight Use for measuring and troubleshooting 4 mA to 20 mA signals -21.0 mA to -99.9 mA +21.0 mA to +99.9 mA 0.1 mA 1 % reading + 5 counts Use for measuring and troubleshooting 10 mA to 50 mA signals Zero, Hold, backlight, measurement spotlight For more information and detailed specifications, go to www.fluke.com/processmeters 9102S and 9100S Handheld Drywell Temperature Calibrators Fluke Corporation, Hart Scientific Division The smallest, lightest and most portable dry-wells in the world • 9100 model weighs only 2 pounds, 3 ounces (1 kilogram) • Temperature ranges from -10 °C to 375 °C • Stability during calibrations to ± 0.05 °C • Fast and easy calibrations of RTDs and thermocouples • Includes RS-232 interface, instrument control software • Direct interface to the Fluke 744 44 Fluke-771 9102S and 9100S ordering information 9100S-A-156 9100S-A-256 9100S-B-156 9100S-B-256 9100S-D-156 9100S-D-256 9300 9102S-156 9102S-256 9320-156 9320-256 Dry-Well, Block A (1) Dry-Well, Block A (2) Dry-Well, Block B (1) Dry-Well, Block B (2) Dry-Well, Block D (1) Dry-Well, Block D (2) Rugged Carrying Case, 9100 Dry-Well, -10 to 122 (2 Wells) (1) (3) Dry-Well, -10 to 122 (2 Wells) (2) (3) Battery Pack, 9102 (1) Battery Pack, 9102 (2) 9102S and 9009 inserts 3102-1 3102-2 9100S 9102S Range 35 °C to 375 °C (95 °F to 707 °F) -10 °C to 122 °C (14 °F to 252 °F) at 23 °C ambient Accuracy ± 0.5 °C ± 0.25 °C Stability ± 0.1 °C at 100 °C ± 0.3 °C at 375 °C ± 0.05 °C at 0 °C Well-to-well uniformity ± 0.2 °C with sensors of similar size at equal depths within wells Stabilization 5 minutes 7 minutes Well depth 102 mm (4 in); 1.6 mm (1/16 in) hole is 89 mm (3.5 in) deep 102 mm (4 in) 3102-7 Removable inserts N/A 1/4 in, 3/16 in (Standard) 1/16 in, 1/8 in, 3/8 in (optional) 3102-8 Power 115 V ac (± 10 %), 1.5 A or 230 V ac (± 10 %, 0.8 A, specify, 50/60 Hz, 175 W 94 V ac to 234 V ac (± 10 %), 50/60 Hz, 60 W; or 12 V dc Size (H x W x D) 57 mm x 125 mm x 150 mm (2.25 in x 4.9 in x 5.9 in) 99 mm x 140 mm x 175 mm (3.9 in x 5.5 in x 6.9 in) Weight 1 kg (2 lb, 3 oz) 1.8 kg (4 lb) NIST-traceable calibration Data at 50 °C, 150 °C, 200 °C, 250 °C, 300 °C and 350 °C Data at -10 °C, 24 °C, 50 °C, 55 °C, 100 °C and 122 °C Process Calibration Tools Milliamp Process Clamp Meter 3102-3 3102-4 3102-6 9308 Insert, AL 1/16 in (1.6 mm) Insert, AL 1/8 in (3.2 mm) Insert, AL 3/16 in (4.8 mm) Insert, AL 1/4 in (6.4 mm) (Standard) Insert, AL 3/8 in (9.5 mm) (Standard) Insert, AL 7/16 in (11.1 mm) (Standard) Insert, AL 5/32 in (4 mm) (Standard) Hard Carrying Case, 9102/9132 (1) 156 Blocks are 115 V 50/60 Hz (2) 256 Blocks are 220 V 50/60 Hz (3) Specify two 3102 inserts Intrinsically Safe Products Calibrators, thermometers and multimeters designed to intrinsic safety standards What is “Intrinsically Safe”? Intrinsic safety is a protection method employed in potentially explosive atmospheres. Devices that are certified as “intrinsically safe” are designed to be unable to release sufficient energy, by either thermal or electrical means, to cause ignition of flammable material (gas or dust/particulates). There are no global intrinsically safe standards or certifications, but there are organizations that influence directives in certain world geographies. Factory Mutual In The United States, Factory Mutual Research, managed by Factory Mutual (FM) Global, is a not-for-profit scientific and testing organization that has tested and certified over 40,000 products in the last 165 years. FM Research has set certification guidelines for equipment used in potentially explosive atmospheres. Canadian Standards Association (CSA) ATEX The primary intrinsically safe standard which has been set in the European Union with the Directive 94/9/EC, commonly called ATEX (“Atmosphères Explosibles,”) French for explosive atmospheres. For more information and detailed specifications, turn to the corresponding non-intrinsically safe product pages (Fluke 707, 718, 725, 574, 68) or go to www.fluke.com/ex Fluke products ATEX certified For additional product detail 87V Ex: Intrinsically Safe True-rms Multimeter See page 14 II 2 G EEx ia IIC T4 707Ex: Intrinsically Safe mA Calibrator II 2 G EEx ia IIC T4 N.I. Class I, Div 2, Groups A-D T4 See page 42 718Ex: Intrinsically Safe Pressure Calibrator II 1 G EEx ia IIC T4 I.S. Class I, Div 1, Groups A-D T4 See page 41 II 1 G EEx ia IIB 171 °C I.S. Class I, Div 1, Groups B-D, 171 °C See page 39 II 1 G EEx ia IIC T4 I.S. Class I, Div 1, Groups A-D T4 See page 41 700PEx: Intrinsically Safe Pressure Modules Fluke 574-NI Nonincendive Infrared Thermometer See page 51 Fluke 68IS Intrinsically Safe Infrared Thermometer Class I, Division 1, Groups A, B, C, D Class I, Zone 0 AEx ia IIC Want to know what industries Intrinsically Safe products are designed for? Want to know why intrinsic safety is so important? Want to make sense of the product ratings and classifications? Fluke 68IS Intrinsically Safe Infrared Thermometer • Laser guided sighting system for easy targeting with 1 % accuracy • 12-point data logging • Advanced optics to measure smaller targets at greater distances • Adjustable emissivity for more accurate temperature measurements • Selectable MAX, MIN, DIF and AVG functions that display values instantly with Hi/Lo Alarm • Expanded measurement range up to 760 °C (1400 °F) • RTD probe accessory included for dual contact and non-contact temperature measurements • Class I, Division 1, Groups A, B, C, D Class I, Zone 0, AEx ia IIC, T4 at 50 °C when used with 9 V alkaline battery Not available for purchase in Europe. Ordering information 725Ex: Intrinsically Safe Multifunction Calibrator Class I, Division 2, Groups A, B, C, D; Class I, Zone 2 IIC Making sense of intrinsic safety and intrinsically safe tools Go to www.fluke.com/ex Accreditation body for North American regulations based in Toronto, Canada. North American Certification Application note, literature code 2096400: See page 53 For more information and detailed specifications, turn to the corresponding non-intrinsically safe product pages (Fluke 87V, 707, 718, 725, 574, 68) or go to www.fluke.com/ex. Fluke-87V Ex Fluke-707Ex Fluke-718Ex Fluke-725Ex Fluke-700PEx Fluke-574-NI Fluke-68IS IS True-rms Multimeter IS Loop Calibrator IS Pressure Calibrator IS Multifuction Process Calibrator Pressure Modules (700P01Ex, 700P05Ex, 700P06Ex, 700P09Ex, 700P24Ex, 700P27Ex, 700P29Ex and 700PA4Ex) Precision Infrared Thermometer w/ Logging SW Nonincendive Infrared Thermometer Intrinsically Safe Intrinsically Safe Products 45 Ti40 and Ti50 Series IR FlexCam® Thermal Imagers The thermal imagers for professionals demanding the best FIND problems faster with Fluke thermal imagers. Reduce costs and maximize uptime with our complete range of imaging solutions. They combine the largest, sharpest images in the industry with innovative, easy-to-use features. Fluke Ti40 and Ti50 Series reveal more with IR Fusion® Technology—merging infrared and visible light images in one display. Fluke puts powerful technology within your reach. Fluke Ti40, Ti45, Ti50, Ti55 Application note, literature code 2764017: Thermography at Ford’s Dearborn Stamping Plant The Dearborn Stamping Plant at Ford’s Dearborn Stamping Plant: has had thermal Thermography cameras on site in the past, but has not met the objectives of a successful thermography program. Today, DSP’s thermography program is a model for the rest of Ford, and the program came on line in a matter of weeks. Want to read more? Download this and other application notes at www.fluke.com/library From start to best-in-Ford in 30 days—and still accelerating The Dearborn Stamping Plant has had thermal cameras on site in the past, but has not met the objectives of a successful thermography program. Today, DSP’s thermography program is a model for the rest of Ford, and the program came on line in a matter of weeks. caption Application Note Lately, there has been a stream of visitors to the Dearborn Stamping Plant (DSP) housed in the historic Ford Rouge Center in Dearborn, Michigan. What’s the attraction? The DSP operation, which manufactures subassembly doors and hoods for the popular Ford F-150 pickup truck, achieved a perfect score in a recent independent audit of its weld effectiveness. That makes the plant best in company— perhaps the best period—when it comes to the precision with which it forms and welds subassemblies. Executives from Ford Motor Company corporate offices and management from other Ford operations want to know how they do it. A significant factor is a condition-monitoring program using thermography or thermal imaging. Thermography itself isn’t new to DSP or new to Ford operations, but the DSP thermography program is unique. After only 30 days, the program scored higher in an insurance audit than any other Ford thermography program had ever scored. It continued to work even when new thermography team members came on board. In the best tradition of Ford’s commitment to continuous improvement, DSP’s thermography program keeps getting better. And possibly the most distinctive aspect: the program is designed around a systems approach and supported by a systems solution. That means it has the potential to be quickly and easily replicated and the possibility of being deployed with equal success and equivalent return on investment in any Ford operation. From the Fluke Digital Library @ www.fluke.com/library Fluke Ti40FT, Ti45FT, Ti50FT, Ti55FT Features – Ti40 and Ti50 Series Imagers Features Ti40 Ti45 Ti50 Ti55 • • • • Choice of 3 interchangeable lenses to cover every application • • • • Large 5” high contrast color LCD for a clear picture independent of lighting conditions • • • • Fully radiometric for detailed temperature analysis and tracking • • • • SmartFocus for best image quality and accurate temperature measurements • • • • Windows® CE based menu structure for ease of use • • • • Personalized instrument set-up for multiple use • • • • CompactFlash memory cards to store over 1000 IR images plus fully radiometric temperature data • • • • SmartView reporting and analysis software included • • • • 180° articulating flexible lens to view images in every situation AutoCapture for making intermittent problems visible • • On-board analysis functions • • User defined text annotations for simplified reporting • FT model FT model FT model FT model IR-Fusion blending thermal and visible light images to easily pinpoint suspect components FT model Pictureinpicture only FT model FT model FT model IR/Visible Alarm FT model FT model FT model Laser pointer for easy targeting FT model FT model FT model FT model Flash and torch light for high quality images in dark environments FT model FT model FT model FT model Complete package The IR FlexCam thermal imagers are delivered as a complete package. 46 • Built-in visible light (digital) camera Thermal Imaging To find the best thermal imaging solution for your application go to our Thermal Imaging Web Selection Guide at www.fluke.com/thermal_imaging IR-Fusion™ Technology IR-Fusion technology simultaneously captures pixel-for-pixel infrared and visible light images and allows full image optimization with 5 different on-camera as well as software viewing modes. With the integrated laser pointer visible on the images, precise and accurate (faulty) component identification is very easy. Full IR Picture-in-Picture Alpha Blending IR/Visible Alarm Full Visible Light Ti40 and Ti50 Series IR FlexCam® Thermal Imagers The thermal imagers for professionals demanding the best Specifications – Ti40 and Ti50 Series Fluke Ti40 Fluke Ti45 Fluke Ti50 Fluke Ti55 Thermal imaging performance Field of view (FOV)* 23° horizontal x 17° vertical Spatial resolution (IFOV)* 2.60 mrad 1.30 mrad Min focus distance* 0.15 m ≤0.09 °C Thermal sensitivity (NETD) at 30 °C Detector data acquisition/image frequency ≤0.08 °C ≤0.07 °C 30 Hz/30 Hz Focus ≤0.05 °C 60 Hz/60 Hz SmartFocus; single finger continuous focus IR digital zoom 2x Detector size 2x 160 x 120 2x, 4x. 8x 320 x 240 Detector type Focal Plane Array, Vanadium Oxide (VOx) Uncooled Microbolometer Spectral band 8 µm to 14 µm Fluke SmartView™ IR analysis and reporting software for Fluke IR cameras. Included with each Fluke IR thermal imager, Fluke SmartView software is a modular suite of tools that annotates, views, edits and analyzes IR images. It also generates fully customizable and professional-looking reports in a few easy steps. The IR-Fusion technology is full supported. The software is easy to use for the technician, yet delivers the performance specialized thermographers require for advanced analysis. Visual Imaging performance (Fusion models only) On-camera operating modes Picture-in-Picture Full thermal, full visual light or merged thermal-visual images • • • • Smartview only • • • Visible light camera 1280 x 1024 pixels, full color (1.3 megapixels) Visible light digital zoom 2x 2x 2x, 4x • • • -20 °C to 600 °C -20 °C to 350 °C -20 °C to 600 °C Visible color alarm above and below Temperature measurement Calibrated temperature range -20 °C to 350 °C 1200 °C High temperature option • Accuracy ± 2 °C or 2 % (whichever is greater) Measurement modes Centerpoint, center box (area min/max, average) • • • • Moveable spots/boxes • • Isotherms, automatic hot and cold point detection • • Emissivity correction 0.1 to 1.0 (0.01 increments) Image presentation Digital display 5” large high-resolution backlight LCD Video output RS170 EIA/NTSC or CCIR/PAL composite video Palettes Grayscale, grayscale inverted, blue red, high contrast, hot metal, ironbow, amber, amber inverted Optional lenses 54 mm Telephoto lens High precision Germanium lens Field of view (FOV) 9° horizontal x 6° vertical Spatial resolution (IFOV) 0.94 mrad Min focus distance 0.47 mrad 0.6 m 10.5 mm wide angle lens High precision Germanium lens Field of view (FOV) 42° horizontal x 32° vertical Spatial resolution (IFOV) 4.9 mrad Min focus distance 2.45 mrad 0.3 m Image and data storage Storage medium Compact flash card (512Mb) stores over 1000 IR images File formats supported 14 bit measurement data included. Images: bmp, gif, jpg, png, tiff; Data formats: comma separated (csv), tab separated (txt) Interfaces and software Interface Compact flash card reader included Included software SmartView; Full analysis and reporting software Laser (IR-Fusion models only) Classification Class II Laser targeting Laser dot visible on blended and visual image Controls and adjustments Set-up controls Date/time, °C/°F, language, scale, LCD intensity Image controls Level, span, auto adjust (continuous/manual) On-screen indicators Battery status, emissivity, background temperature and real time clock Battery life: 3 hours continuous operation (2 hours on FT models) Water and dust resistant: IP54 Size (HxWxD): 162 mm x 262 mm x 101 mm (6.378 in x 10.315 in x 3.9764 in) Weight: 1.85 kg (4.07 lb) Two-year warranty Recommended accessories – Ti40 and Ti50 Series Imagers 103232 Anti-glare Hood 104543 Car Charger Ti-SBC Battery Charger Ti-SBP Rechargeable Battery Pack Included accessories AC adapter (for Ti45 and Ti55 only), video cable, 512 MB compact flash card, compact flash card reader and USB cable, PCMCIA compact flash card adapter, SmartView reporting and analysis software on CD, 2 rechargeable battery packs, battery charger, neck strap, heavy duty carrying case and user manual on CD. Ordering information Fluke-Ti40-20 IR FlexCam Thermal Imager Fluke-Ti40FT-20 IR FlexCam Thermal Imager with IR-Fusion Fluke-Ti45-20 IR FlexCam Thermal Imager Fluke-Ti45FT-20 IR FlexCam Thermal Imager with IR-Fusion Fluke-Ti50-20 IR FlexCam Thermal Imager Fluke-Ti50FT-20 IR FlexCam Thermal Imager with IR-Fusion Fluke-Ti55-20 IR FlexCam Thermal Imager Fluke-Ti55FT-20 IR FlexCam Thermal Imager with IR-Fusion *For ordering information of optional lenses check the Fluke web. Thermal Imaging 47 Fluke Ti20 Thermal Imager Everything needed for everyday imaging The Fluke Ti20 Thermal Imager is an unbeatable solution for predictive maintenance and troubleshooting. • Complete imaging solution. The Ti20 Thermal Imager is packaged with all necessary accessories including unlimited-use InsideIR™ companion software and professional training materials. • Lowest cost of ownership. An exceptional value for a high performance imager, the Ti20 also offers affordable instrument service and calibrations. • Designed for industrial use. Rugged Fluke construction; IP54-rated for use in dust and moisture filled environments. • Fast and easy inspection routing. Plan your equipment inspection route, load it once into the imager, and then follow the easy, oncamera instructions each time you perform inspections (simply point, focus and pull the trigger). Specifications – Ti20 Thermal Imager Detector Detector type 128 x 96 thermal element focal plane array (FPA) uncooled microbolometer NETD (thermal sensitivity) ≤ 0.2 °C at 30 °C Thermal Temperature range -10 °C to 350 °C (14 °F to 662 °F) Accuracy ± 2 °C or 2 % (whichever is greater) Optical Field of View (FOV) 20° horizontal by 15° vertical Optical resolution (D:S) 75:1 or better Target sighting Single laser dot (Meets IEC Class 2 and FDA Class II requirements) Typical thermal imaging applications Electric motors and pumps Hot spots may be an early indicator of motor winding problems. Elevated temperatures can damage winding insulation, resulting in operational inefficiencies and premature motor failure. An overheated motor may be an indication of an underrated motor in the application, insufficient cooling or electrical power problems. Bus bars and fuse boxes Temperature differences between phases may indicate unbalanced loads, harmonics, component problems, bad connections or bad wiring. These conditions can result in increased energy cost and can damage cables or machines or possibly cause fire. Even small temperature differences between phases should be investigated to determine the root cause. Controls and adjustments Focus Manual Minimum focus distance 0.15 m (6 in) Temperature scale ºC or ºF selectable Palettes Grayscale, reverse grayscale, rainbow, ironbow Measurement modes Auto and manual LCD backlight On/off selectable Adjustable emissivity 0.10 to 1.00 in 0.01 increments Adjustable reflected background temperature -50 °C to 460 °C (-58 °F to 860 °F) Environmental Ambient operating temperature 0 °C to 50 °C (32 °F to 122 °F) Relative humidity 10 % to 95 % non-condensing Storage temperature -25 °C to 70 °C (-13 °F to 158 °F) Water and dust resistant IP54 Rotating machinery Ball bearings showing an increased temperature are an indication that either the quality of the lubricant is deteriorating or there is poor alignment between the motor and shaft. These problems can cause the bearings to fail, or a motor or pump to overheat. Other Display Large color LCD Storage capacity 50 images stored internally Power Rechargeable battery pack or six AA batteries Battery life Three hours continuous use Image frame rate 30 Hz*, 9 Hz Thermal analysis software InsideIR™ (included) full-featured analysis and reporting software (unlimited use; no per user license fees) Size (HxWxD) 40.64 x 20.32 x 30.48 cm (16 in x 8 in x 12 in) Weight 1.2 kg or (2.65 lbs) Warranty One-year *Subject to U.S. export license compliance. Applicable outside the U.S. and Canada. Recommended accessories – Ti20 Thermal Imager Ti20-Visor Sun Visor Ti30-TBP Rechargeable Battery Pack Ti20-CC Car Charger For more information and detailed specifications, go to www.fluke.com/thermal_imaging 48 Thermal Imaging Included accessories Unlimited-use InsideIR PC software for data storage, analysis and reporting, ac/dc power adapter, USB communication cable, hard carrying case, soft-sided carrying case, wrist strap, two (2) rechargeable battery packs, one (1) AA battery carrier, training materials and getting started guide. Ordering information Fluke-TI20 US Thermal Imager North America Fluke-TI20 INT Thermal Imager Ampac Fluke-TI20 INT 9 Thermal Imager Ampac 9 Hz Fluke Ti30™ Thermal Imager Thermal imaging for the industrial technician The affordable Fluke Ti30™ Thermal Imager is an unbeatable solution for predictive maintenance: Complete imaging solution – The Ti30 Thermal Imager is packaged with all necessary accessories, unlimited-use InsideIR™ companion software, and two days of professional thermography training.* Low cost of ownership – An exceptional value for a high performance imager, the Ti30 also offers affordable instrument service and calibrations. Designed for industrial use – Over five hours of continuous-use battery life and the capacity to store up to 100 images, allows for a full day of uninterrupted inspections. Fast and easy inspection routing – Plan your equipment inspection route, load it once into the imager, and then follow the easy, on-camera instructions each time you perform inspections. *U.S. and Canada only. Training package varies by country. Does not include travel expenses. Specifications – Ti30™ Thermal Imager Detector Detector type 120 x160 thermal element uncooled focal plane array microbolometer NETD (Noise equivalent temp. difference) 200 mK Thermal Temperature range -10 °C to 250 °C (14 °F to 482 °F) Accuracy ±2 % or ±2 ºC (± 3 % or 3 °C from -10 to 0 °C) Understanding maintenance routing Predictive maintenance (PdM) programs rely on periodic inspections of the critical assets comprising a plant or facility. These inspections range from visual inspections to nondestructive testing performed using a variety of technologies. To optimize a PdM program, one must develop a series of routes, determining the equipment to be inspected, the frequency of those inspections, and the sequence or physical course for each. With the Fluke Ti30™ Thermal Imager, images taken on a planned inspection route can be combined with location names and temperature data and uploaded to the camera for use as a “routing guide.” The user is prompted to go to each location on the route to take images during subsequent inspections—improving accuracy. New images can easily be compared to previous scans using InsideIR software (included), helping to identify potential problems before they cause failure. To learn more about predictive maintenance with the Fluke Ti30™ Thermal Imager, go to www.fluke.com/thermal_imaging Optical Optical resolution 90:1 Slit response optical resolution 225:1 Minimum diameter measurement spot 7 mm (0.27 in) at 61cm (24 in) Field of view (FOV) 17 º horizontal x 12.8 º vertical Target sighting Single laser dot (Meets IEC Class 2 & FDA Class II requirements) Controls and adjustments Focus Focusable, 61cm (24 in) to infinity Temperature scale ºC or ºF selectable Palettes Gray, ironbow or rainbow Measurement modes Automatic, semi-automatic or manual LCD backlight Bright, dim, off-selectable Adjustable emissivity 0.10 to 1.00 by 0.01 Reflected background temperature -50 ºC to 460 ºC (-58 ºF to 860 ºF) Environmental Ambient operating temperature -10 ºC to 50 ºC (14 ºF to 122 ºF) Relative humidity 10 to 90 % non-condensing Storage temperature -25 ºC to 70 ºC (-13 ºF to158 ºF) [without batteries] Other Storage capacity 100 images Power Rechargable battery pack or 6AAs (not included) Battery life Minimum 5 hours continuous use Image frame rate 20 Hz*, 9 Hz Thermal analysis software InsideIR (included) PC software operating systems Microsoft® Windows® 2000® or XP® Weight (includes batteries) 1 kg (2.2 lb) Warranty 1 year (U.S. only) *Subject to U.S. export license compliance. Applicable outside the U.S. and Canada. Store infrared images in InsideIR software Included accessories Unlimited-use InsideIR PC software for data storage, analysis and reporting, docking station with universal power adapter and USB connection, hardshell carrying case, USB field cable, rechargeable battery pack, sun visor, interactive CD, training presentation CD, carrying pouch, wrist strap, and quick reference card. Optional NIST Calibration Certificate Ordering information Fluke-Ti30 US Thermal Imager/ North America Fluke-Ti30 EL Thermal Imager/ Latin America Fluke-Ti30 EL/9 Thermal Imager/ Latin America, 9 Hz Version To request a demonstration, call 1-800-44-Fluke (1+425-446-5500 outside the U.S.) or visit www.fluke.com/demo For more information and detailed specifications, go to www.fluke.com/thermal_imaging Thermal Imaging 49 FlexCam™ TiR4, TiR3, and TiR2 IR Thermal Imagers The expert’s choice for building diagnostics Fluke TiR2, TiR3, TiR4 Fluke TiR2/FT, TiR3/FT, TiR4/FT The new Fluke TiR2, TiR3 and TiR4 thermal imagers are for professionals demanding the best and most thorough solutions in building diagnostics applications. The Fluke TiR-Series provides the industry’s largest LCD to view on-camera images, augmented with the innovative IR-Fusion™ technology to better pinpoint building problems. IR-Fusion is the overlay of IR and visible images, allowing one to clearly identify critical points within the thermal image. • Industry leading thermal sensitivity (≤ 0.050 °C NETD on TiR4) (0.07 °C NETD on TiR2 and TiR3) provides solid resolution, and ultra high-quality images. • IR-Fusion technology automatically merges visual and thermal images pinpointing trouble areas quicker by automatically relating thermal images with the real world. (included with Flk-TiR/FT series, optional with Flk-TiR series) IR InSight XS & XST Thermal Imagers The New Fluke IR InSight XS & XST portable infrared imagers combine outstanding image quality and thermal sensitivity. They are optimized for low contrast thermal applications encountered in building sciences applications and show problems that other infrared cameras cannot. These easy to use cameras include SmartView™ software to customize and prepare professional infrared survey reports. • • • • • • • • The 180° articulating lens is great for viewing around obstructions. The 5” high resolution, high contrast display is the biggest display in the industry. 320 x 240 focal plane array and 20 mm high quality Germanium lens with continuous single finger focus provide exceptional image resolution (Model TiR2 available with 160 x 120 only). • SmartView™ professional report writing software generates fast, easy customizable reports including rich image analysis. • The intuitive operation with on-camera Windows CE interface makes it easy to use. 160x120 focal plane array 0.07 °C (Industry leading thermal sensitivity (≤ NETD) Simple robust one-button operation 3.5-inch, 30 bit color, high resolution, high-contrast display SmartView professional report writing software TiR2, TiR3 and TiR4 Included accessories AC adapter (for TiR2 and TiR4 only), video cable, 512 MB compact flash card, compact flash card reader and USB cable, PCMCIA compact flash card adapter, SmartView reporting and analysis software on CD, 2 rechargeable battery packs, battery charger, neck strap, heavy duty carrying case and user manual on CD. InSight XS and XST Included accessories Serial/USB download adapter kit/ cable, SmartView reporting software on CD, 2 rechargeable battery packs, battery charger, neck strap, heavy-duty carrying case, user manual on CD. IR-Fusion™ Technology Infrared and visible light images fused together on one display. IR-Fusion Technology captures a visible light image in addition to the infrared image and takes the mystery out of IR image analysis. It helps to better identify and report suspect areas and enable the repair to be done right the first time. • Full IR – for analyzing very high resolution IR imaging. Detect the smallest temperature variations to track down the origin of problems and fully document the extent of remediation. Full IR images are automatically linked to full visible light images. 50 Thermal Imaging • Picture-in-Picture – for creating an IR “window” surrounded by a visible light frame to easily identify thermal anomalies, while maintaining a frame of reference with surroundings. • Alpha blending – for combining visible and infrared images together in any ratio to create a single image with enhanced detail that will help in precisely locating problems. • IR/visible alarm – for displaying only temperatures that fall above, below, or in between a specified range as IR image, leaving the rest of the scene as a fully visible light image. • Full visible light – a bright, detailed pixel-for-pixel reference image of subject areas for documentation and reporting. Ordering information Flk-TIR2-20 Flk-TIR2/FT-20 Flk-TIR3-20 Flk-TIR3/FT-20 Flk-TIR4-20 Flk-TIR4/FT-20 Flk-INSXT-20 Flk-INSXS-20 IR Flexcam BD Thermal Imager IR Flexcam BD Thermal Imager with IR-Fusion IR Flexcam BD Thermal Imager IR Flexcam BD Thermal Imager with IR-Fusion IR Flexcam BD Thermal Imager IR Flexcam BD Thermal Imager with IR-Fusion IR InSight, 20MM, XST IR InSight, 20MM, XS Fluke 570 Series Infrared Thermometers The predictive maintenance professional’s precision diagnostic tool The Fluke 572, 574 and 576 non-contact thermometers are ideal professional diagnostic tools for maintenance professionals requiring the most accurate temperature readings at all distances. Predictive maintenance professionals requiring analysis and documentation use the 574 or 576 models, with 100-point data logging and digital photographs (576 only) with the included software for graphing and analysis for follow-up reporting and documentation. • Backlit display for poorly lit areas • Displays last ten temperature readings on bar graph for easy reference • Enhanced optics (distance to spot ratio up to 60:1) allow measurements of smaller objects from farther away • Coaxial three-dot laser sighting system highlights the true diameter of measurement spots at all distances • Adjustable emissivity setting (all models) and 30 pre-set common material values (574, 576) for more accurate measurements • 100-data point logging for documentation (574, 576) • Customizable log names, alarms, and emissivity values for personalized measurements (574, 576) • Software to log, graph, and analyze temperature data via RS-232 (574) connection or USB connection (576, includes photo viewing feature) • Instantly captures photographs of measurement locations along with temperature and date-time information for improved documentation and maintenance follow-up (576) • Close-focus option available for specialized applications • Durable hard plastic storage case Specifications – 572, 574 and 576 IRTs Models Fluke-572 Temperature range D:S (Distance to Spot size) Fluke-574 Fluke-574-NI -30 °C to 900 °C (-25 °F to 1600 °F) 60:1 [50:1 with close focus option (close focus not available with NI model)] Laser sighting 3-dot, coaxial, extra-bright Emissivity Adjustable Adjustable, plus table of 30 preset values ± 0.75 % of reading or (± 0.75 °C (± 1.5 °F) whichever is greater (assumes ambient operating temperature of 23 °C [73 °F]) Accuracy Response time Yes LCD backlit Yes MAX, MIN temperatures Yes No Yes Recall last reading Audible/visible LO alarm Yes Yes Yes Yes Yes Audible/visible HI alarm Yes No Yes Bar graph display Yes 100 points data logging No Yes Yes Yes Data graphing software (Windows 2000, XP compatible) No Yes Yes Yes Photo viewing software (Windows 2000, XP, NT compatible) No No No Yes 26 images (640 x 480 pixel) No No No Yes 100 images (320 x 240 pixel) No No No Yes Image file format (.jpg) No No No Yes Protective hard case Weight Dimensions Power Yes 472 g (1 lb, 1 oz) 2 AA batteries Warranty Additional options/accessories 480 g (1 lb, 1 oz) 480 g (1 lb, 1 oz) 16.7 cm x 5 cm x 19.8 cm (6.58 in x 1.97 in x 7.80 in) 2 AA batteries/ AC adapter 2 AA batteries/ AC adapter 580 g (1 lb, 1 oz) 16.7 cm x 5 cm x 23.8 cm (6.58 in x 1.97 in x 9.57 in) 2 AA batteries/ USB Two-years, conditional Nylon holster, NIST Traceable Calibration Certificate Nylon holster, NIST Traceable Calibration Certificate, Analog cable For more information and detailed specifications, go to www.fluke.com/thermometers When safety is a concern and data logging and downloading are required, the Fluke 574 Nonincendive (NI) model thermometer is the product to choose. It has the same great features as the standard 574 model thermometers with the extra confidence of a Factory Mutual approval for use in hazardous environments. Class I, Division 2, Groups A, B, C, D: Class I, Zone 2 IIC; T4 Ta=50 °C when used with 1.5 V alkaline batteries. Fluke 576 Photographic Non-contact Thermometer The Fluke 576 thermometer measures temperature while digitally photographing the measured area and its surroundings. The 576 allows you to: • Ensure consistency of repeated measurements by using prior photos as a reference. • Position the laser sighting to assure the measurement area is the same. • Create customized company reports with the software, data and photos, using standard Windows programs. Included accessories 2 AA batteries, operator’s guide (on CD), durable hard case. thermocouple K probe (574, 576), power supply (574), RS-232 data cable (574), USB 1.1 cable (576), data graphing, storage and analysis software on CD (574, 576) Ordering information 250 mSec Display hold (7 seconds) DIF, AVG temperatures Fluke-576 574-NI Nonincendive Thermometer Fluke-572 Fluke-572-CF Fluke-574 Fluke-574-NI Fluke-574-CF Fluke-576 Fluke-576-CF Precision Infrared Thermometer Precision Infrared Thermometer with Close Focus Option Precision Infrared Thermometer w/Logging SW Precision Infrared Thermometer w/Logging SW Nonincendive Precision Infrared Thermometer w/Logging SW Close Focus Precision, Photographic Infrared Thermometer w/Logging SW Precision, Photographic Infrared Thermometer w/Logging SW Close Focus Thermometers 51 Fluke 54 Series II Thermometer Lab accuracy in a field thermometer The Fluke 51, 52, 53 and 54 Series II Thermometers offer high accuracy with fast response times to quickly capture your measurement and show trends. Choose from four models to get the functionality, thermocouple support and data logging you need. All models offer: • Laboratory accuracy: ± (0.05 % + 0.3 °C) • Large backlit dual display presents all the information • • • • • • • you need at a glance MIN, MAX, and AVG—with time references—captures major events Electronic Offset function maximizes overall accuracy by allowing you to compensate for thermocouple errors Supports a wide range of thermocouple types Temperatures displayed in °C, °F, or Kelvin (K) Splash and dust resistant case Sleep mode to increase battery life (typical 1000-hour life) Battery door allows easy battery replacement without breaking the calibration seal Powerful data logging capabilities The Fluke 53 and 54 Series II can log up to 500 points of data to internal memory. • User-adjustable recording intervals • Real-time clock captures the exact time of day of events • Recall function allows logged data to be easily reviewed on the meter display • For further analysis and graphing, data can be exported to optional FlukeView® PC software using the thermometer’s IR communication port Fluke 561 HVACPro Two-in-one infrared and contact thermometer for HVAC/R professionals The Fluke 561 HVACPro combines the temperature measurement functions that professionals need for most HVAC jobs, all in one tool. It measures both IR and contact temperature, replacing several hundred dollars worth of equipment. • IR thermometer for measurements up close or at a distance, without a ladder • Contact thermometry capability, compatible with all standard mini-connector K-type thermocouples, preserves your investment in thermocouples • Velcro® pipe probe for superheat and sub-cooling and other contact and ambient measurements • MIN, MAX and DIF functions help you quickly identify problems • Scan large areas or small objects quickly and efficiently Specifications – 51, 52, 53 and 54 Series II Feature 51 52 53 54 Thermocouple types K,J,T,E K,J,T,E K,J,T,E,N,R,S K,J,T,E,N,R,S Number of inputs Single Dual Single Dual Relative time Relative time Time of day Time of day Time stamp Temperature measurement accuracy (for temperatures above -100 °C) Type J,K,T,E,N: ± [0.05 % + 0.3 °C (0.5 °F)] Type R,S: ± [0.05 % + 0.4 °C (0.7 °F)] Measurement range (depending on thermocouple type) Display resolution -250 °C (-418 °F) to 1767 °C (3212 °F) 0.1 °C /°F/K < 100° Operating temperature 1° °C/°F/K > 1000° -10 °C to 50 °C (14 °F to 122 °F) Storage temperature -40 °C to 60 °C (-40 °F to 140 °F) Humidity 0 % to 90 %; 0 °C to 35 °C (32 °F to 95 °F), 0 % to 70 %; 0 °C to 50 °C (32 °F to 122 °F) Weight 400 g (14 oz) Size (HxWxD) 17.3 cm x 8.6 cm x 3.8 cm (6.8 in x 3.4 in x 1.5 in) Battery 3 AA batteries; typical 1000-hour life Recommended accessories – 51, 52, 53 and 54 Series II Thermometers TPak ToolPak Meter Hanging Kit See page 71 80PK-8 Pipe Clamp Temperature Probe See page 68 80PK-22 SureGrip™ Immersion Temperature Prove See page 68 80PK-25 SureGrip™ Piercing Temperature Probe See page 68 FVF-SC1 FlukeView Forms Software See page 65 For more information and detailed specifications, go to www.fluke.com/thermometers 52 Thermometers Included accessories Fluke 50 Series II includes: 80PK-1 Bead Thermocouple(s), batteries, overview manual and instructional guide on CD-ROM. Fluke 561HVACPro includes: Infrared thermometer with contact thermometer capabilities, thermocouple K-type Velcro® pipe probe, hand-carrying case and user manual with HVAC measurement guide. Ordering information Fluke-51-2 Fluke-52-2 Fluke-53-2 Fluke-54-2 Fluke-561 Digital Thermometer, Single Input Digital Thermometer, Dual Input Datalogging Thermometer, Single Input Datalogging Thermometer, Dual Input HVACPro Thermometer Fluke 68 Infrared Thermometer Measuring temperature in hard-to-reach, hot, rotating or dangerous situations Reach for a rugged Fluke IR thermometer. You get easy and safe temperature readings in less than a second. These handheld portable tools enable professionals to research heating and ventilation problems, monitor the status of electrical motors and electrical panels and diagnose car malfunctions with ease. New! Fluke 62 Mini Infrared Thermometer • Temperature measurement range up to 500 ºC (932 ºF) 10:1 optics Accurate to within ± 1.5 % of reading or ± 1.5 °C • MAX temperature display • Laser sighting • Backlit display • • Fluke 63, 66 and 68 pistol grip infrared thermometers The new Fluke 63, 66 and 68 pistol grip thermometers offer an easy to use solution for temperature measurement in hard-to-reach, hot, rotating or dangerous situations. • Wide temperature range and quick response time • Superb optics for measuring temperature of surfaces from a distance • Laser sighting • Adjustable emissivity (66/68 only) for more accurate temperature measurement Intrinsically safe Fluke 68 version available (see page 45) Specifications – 561, 61, 62, 63, 66, 68 561 Temperature range Emissivity 61 Adjustable with three settings: Low (0.3), Medium (0.7), High (0.95) Optical resolution (D:S) 12:1 Laser sighting (class II) Single point laser Response time 500 mSec (95 % of reading) Repeatability 63 8:1 10:1 at 80 % energy < 500 mSec < 500 mSec Digitally adjustable (from 0.1 to 1.0 by 0.01) 12:1 30:1 50:1 < 0.5 second (95 % of reading) 25 mm (1 in) 0.1 °C (0.1 °F) of reading 24 mm (0.9 in) 0.2 °C (0.5 °f) ± 0.5 % of ± 2 °C or reading or ± 1 °C ± 2 %, whichever (± 2 °F), whichis greater ever is greater 18 mm (0.7 in) 0.1 °C (0.1 °F) button operation Easy targeting with bright laser • Shock-absorbing molding increases ruggedness • 0 °C to 50 °C (32 °F to 120 °F) 10 to 90 % RH 10 to 90 % RH non-condensing, noncondensing, at at < 30 °C (86 °F) < 50 °C (120 °F) Storage temperature -20 °C to 65 °C (-25 °F to 150 °F) Dimensions 17. 8 cm x 16.5 190 mm x 51 mm 152 mm x 101 mm cm x 5.1 cm (7 in x 41 mm (7.5 in x x 38 mm (6 in x x 6.5 in x 2 in) 2 in x 1.6 in) 4 in x 1.5 in) Weight 330 g (11.6 oz) Power 2 AA batteries (alkaline or NiCD) Battery life (alkaline) -20 °C to 60 °C (-4 °F to 140 °F) without battery 341 g (0.75 lb) 10 to 90 % RH non-condensing, at < 30 °C (86 °F) ambient -20 °C to 65 °C (-4 °F to 150 °F) without battery -20 °C to 60 °C (-13 °F to 158 °F) without battery Included accessories 200 mm x 160 mm x 55 mm (8 in x 6 in x 2 in) 200 g (7 oz) 320 g (11 oz) 12 hours 10 hours with laser and backlight on, 40 hours with laser and backlight off 20 hours with laser and backlight on 50 % 40 hours with laser and backlight off Up to 2 m (6 ft) 1 m (3 ft) Up to 2 m (6 ft) Up to 2 m (6 ft) Up to 5 m (15 ft) Up to 8 m (25 ft) Two-year limited One-year Two-year limited Two-year limited Two-year limited Two-year limited 80PR-60 Temperature Probe (66/68 only) See page 69 H6 Meter Case (63/66/68 only) See page 70 LVD1 Volt Light (all models) See page 64 C510 Meter Case (61 only) See page 70 Fluke 61 includes: instruction sheet and 9 V battery. Fluke 62 includes: storage pouch and instruction sheet. 9 V alkaline or customer supplied NiCd battery Recommended accessories – 60 Series Thermometers Fluke 61 Infrared Thermometers • Easy to use one ± 0.5 % or < ± 1 °C (± 2 °F), whichever is greater Relative humidity Warranty 68 Offset single point laser Ambient operating temperature Typical distance to target 66 -30 °C to 500 °C -32 °C to 535 °C -32 °C to 600 °C -32 °C to 760 °C (-20 °F to 932 °F) (-25 °F to 995 °F) (-25 °F to 1100 °F) (-25 °F to 1400 °F) Fixed at 0.95 Minimum usable spot size Resolution 62 -40 °C to 550 °C -18 °C to 275 °C (-40 °F to 1022 °F) (0 °F to 525 °F) Fluke 63, 66, 68 includes: carrying case, hand strap, instruction manual and 9 V battery. Ordering information Fluke-61 Fluke-62 Fluke-63 Fluke-66 Fluke-68 Fluke-68IS Infrared Thermometer Mini Infrared Thermometer Infrared Thermometer Infrared Thermometer Infrared Thermometer Intrinsically Safe Infrared Thermometer C90 Meter Case (61 only) See page 70 For more information and detailed specifications, go to www.fluke.com/thermometers Thermometers 53 Fluke 975 AirMeter™ Five powerful tools in one, with simple one-touch air velocity The Fluke 975 test tool combines five powerful air quality tools into one. Identify and diagnose indoor air quality issues quickly and easily with one rugged, handheld device. The Fluke 975 measures and simultaneously displays temperature, humidity, CO2 and CO. At the press of a button, it quickly measures air flow and percentage of outside air. • Simultaneously measures, logs, and displays temperature, humidity, CO2, and CO on a bright, backlit LCD display • One-touch air flow and velocity with available probe* • Wet bulb and dew point temperature • % of outside air calculation • CO2 and CO field calibration feature • Automatically compensates for barometric pressure changes • Min/Max/Average on all measured and calculated readings • Audible and visual threshold alarms • Extensive discrete or continuous data logging capacity, downloadable to PC via USB interface Also available: Fluke-975CK AirMeter Calibration Kit includes the gases and tools necessary to keep your Fluke 975 AirMeter calibrated. Fluke-975AP AirMeter Velocity Probe for use with Fluke 975 AirMeter. *Included with Fluke 975V, optional with Fluke 975 Temperature Relative humidity Range Display Resolution -20 °C to 50 °C (-5 °F to 122 °F) 0.1 °C (0.1 °F) Accuracy ± 0.9 °C/± 1.62°F from 40 °C to 60 °C ± 0.5 °C/± 1.00°F from 5 °C to 40 °C ± 1.1 °C/± 1.98 °F from -20 °C to 5 °C 10 % to 90 % RH non-condensing 1% 50.0 fpm to 3000 fpm 0.25 m/sec to 15 m/sec 1 fpm (0.005m/sec) ±4 % or 4 fpm* ±4 % or 0.02 m/sec* whichever is greater *Accuracy specification only valid for velocity readings above 50 fpm. CO2 0 to 5000 ppm 1 ppm Warm up time 1 min (5 minutes for full specification) 2.75 % + 75 ppm CO 0 to 500 ppm 1 ppm ± 5 % or ± 3 ppm, whichever is greater, @ 20 °C and 50 % RH Air velocity ± 2 % RH (10 % RH to 90 % RH) Fluke 902 True-rms HVAC Clamp Meter Get more done Heating, ventilation, air conditioning (HVAC) technicians require a service tool that can consistently keep up with their demands. The Fluke 902 expands the existing line of quality Fluke clamp meters by delivering the features necessary to diagnose and repair HVAC systems. Combined with True-rms technology and a CAT III 600 V rating, the Fluke 902 helps technicians do their jobs safely and accurately. • Designed for HVAC applications with capacitance, dc current (µA), and temperature measurements • Small body and jaws fit perfectly in your hand and into tight places • Handy ‘Display Hold’ button keeps measurements on the display • Meter controls are positioned so current measurements can be done with one hand (index finger on clamp opening lever and thumb on rotary switch) Range Voltage dc 0 - 600 V 1 % ± 5 counts Voltage ac (True-rms) 0 - 600 V 1 % ± 5 counts (50/60 Hz) Current ac (True-rms) 0 - 600 A 2.0 % ± 5 counts (50/60 Hz) Current dc 0 - 200 µA 1.0 % ± 5 counts Resistance 0 - 9999 W 1.5 % ± 5 counts Continuity 7247001) 45 (S/N < 7211001) 45 (S/N > 7211001) 73 and 73-II 863/865/867/867B 83/85/87 (S/N > 65650001) 87-IV/89-IV/187/189/ 83-III/85-III/87-III/87E-III/83V/87V 23-III/77-III/26-III/79-III/175/177/179 111/112 712/713/714/715/716/717/718 724/725 1577/1587 1503/1507 formula removes surface dirt, oil and grease • Safe on rubber • Safe to the environment • Comes in two sizes: 6-pack (MC6) and 50-pack (MC50) Verification tools • Model 21/23/75/77-II New! MeterCleaner Wipes • Industrial strength cleaning Fuse requirements P/N 871173; 630 mA 250V fuse P/N 892583; 15 A 600 V fuse P/N 871173; 630 mA 250 V fuse P/N 803293 11 A 1000 V fuse P/N 871207; 1 A 600 V fuse P/N 892583; 15 A 600 V fuse P/N 871173; 630 mA 250 V fuse P/N 871202; 3A 600 V fuse P/N 892583; 15A 600 V fuse P/N 943121; 440 mA 1000 V fuse P/N 803293; 11A 1000 V fuse P/N 871181; 500 mA 250 V fuse P/N 892583; 15 A 600 V fuse P/N 871181; 500 mA 250 V fuse P/N 943121; 440 mA 1000 V fuse P/N 803293; 11 A 1000 V fuse P/N 892583; 15 A 600 V fuse P/N 943121; 440 mA 1000 V fuse P/N 803293; 11 A 1000 V fuse eliminates noise and false signals New SmartTone™ analog toning precisely isolates individual wire pairs Locates cables safely and effectively on active networks Verifies twisted-pair installation with visual end-to-end continuity test Identifies, diagnoses, and troubleshoots datacom/telecom services Test the integrity of UTP, Coax, phone and security cabling using known standards. MicroScanner Pro • The essential cable verification tester • Measures length and distance to • • • • • fault via true TDR (Time Domain Reflectometry) Pinpoints opens, shorts, reversed, crossed and split pairs Tests UTP, STP and coax cables Flashes hub and switch port lights Identifies active networking hubs and detects speed/duplex settings Analog tone generator with four song selections MicroMapper P/N P/N P/N P/N P/N 803293; 11 A 1000 V fuse 686527; 125 mA 250 V fuse 2002234 (qty. 1); 50 mA 250 V fuse 943121; 440 mA 1000 V fuse 2279339; 315 mA, 1000 V fuse • The fast, comprehensive LAN wiremap checker • Tests twisted-pair cables for opens, shorts, crossed pairs, split pairs, or any miswires Verifies correct pin outs, wiremap • For more information and detailed specifications, go to www.fluke.com/accessories Accessories 71 What’s New from Fluke The new products to help keep you up and running Fluke Ti20 Thermal Imager The Fluke Ti20 Thermal Imager is an unbeatable solution for predictive maintenance and troubleshooting. • Includes unlimited-use InsideIR™ companion software and professional training materials. • Designed for industrial use. IP54-rated for use in dust and moisture filled environments. • Follow easy, on-camera instructions each time you perform inspections (simply point, focus and pull the trigger) for fast and easy inspection routing. For more information, see page 48. Fluke 117 Electrician’s Digital Multimeter The Fluke 117 is one of four new compact digital multimeters. Choose from models specifically designed for Commercial Electricians, HVAC/R Technicians and Field Service Technicians. Engineered by you, designed by Fluke. • VoltAlert™ Technology for integrated non-contact voltage detection. • AutoVolt feature for automatic ac/dc voltage selection. • LoZ: low input impedance prevents false readings due to “ghost voltage”. For more information, see page 17. Fluke 975 AirMeter™ The Fluke 975 AirMeter test tool raises indoor air monitoring to the next level by combining five powerful tools in one, rugged and easy-to-use handheld device. The Fluke 975 measures: • Temperature • Relative Humidity • Air Velocity • CO2 • CO For more information see page 54. Your authorized Fluke distributor Fluke 8845A and 8846A 6.5 Digit Precision Multimeters • 6.5 digit resolution • Graphical display • Basic V dc accuracy of up to 0.0024 % • 100 uA to 10 A Current • 10 ohm to 1 Gohm resistance • 2x4 Wire ohms measurement technique • Frequency, period, capacitance and RTD temperature measurements • Analytical modes; TrendPlot,™ Histogram and Statistics • USB device port, for memory storage devices • RS-232, IEEE-488 and LAN interfaces For more information, see page 21. Fluke. Keeping your world up and running.™ Fluke Corporation PO Box 9090, Everett, WA USA 98206 Fluke Europe B.V. PO Box 1186, 5602 BD Eindhoven, The Netherlands For more information call: In the U.S.A. (800) 443-5853 or Fax (425) 446-5116 In Europe/M-East/Africa (31 40) 2 675 200 or Fax (31 40) 2 675 222 In Canada (800) 36-FLUKE or Fax (905) 890-6866 From other countries +1 (425) 446-5500 or Fax +1 (425) 446-5116 Web access: http://www.fluke.com ©2006 Fluke Corporation. All rights reserved. Specifications subject to change without notice. LEM is a trademark of LEM Holding S.A. Corporation. Microsoft is a registered trademark of Microsoft Corporation. Printed in U.S.A. 11/2006 1274458 C-US-N Rev O Volume 37
80PJ-1 价格&库存

很抱歉,暂时无法提供与“80PJ-1”相匹配的价格&库存,您可以联系我们找货

免费人工找货