Kellems® Wire Management Products
www.hubbell-wiring.com
Pulling Grips
Support Grips
Strain Relief Grips
Cord Connectors
Index
Index
Product
Page
Kellems® Wire Mesh Grips Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .T-2
Quick Reference Selection Guide for Grip Applications . . . . . . . . . . . . . . . . . . . .T-4
Pulling Grips . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .T-5
Overhead DUA-PULL® Pulling Grips . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .T-6
Overhead Multiple Strength Pulling Grips . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .T-7
Underground K-Type Pulling Grips . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .T-8
Underground T-Type Pulling Grips . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .T-9
Special Purpose Pulling Grips . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .T-10
Low Tension Pulling Grips . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .T-12
Wire Rope Splicing Grips . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .T-13
Cable Splicing Grips . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .T-14
Tools and Bands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .T-15
Swivels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .T-16
Technical Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .T-17
Support Grips . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .T-28
Standard Duty Support Grips . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .T-30
Heavy Support Grips . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .T-34
Service Drop Grips . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .T-36
Bus Drop Support Grips . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .T-38
Conduit Riser Grips . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .T-39
Support Grips Technical Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .T-42
Conduit Riser Grips Technical Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . .T-47
Fiber Optic Cable Grips . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .T-49
Pulling Grips . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .T-50
Support Grips . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .T-53
Technical Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .T-54
Hose Containment Grips . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .T-58
Strain Relief Grips for Flexible Cords . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .T-59
Deluxe Cord Grips . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .T-60
PG and Metric Threaded Deluxe Cord Grips . . . . . . . . . . . . . . . . . . . . . . . . . . . .T-64
Dust-Tight Strain Relief Grips . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .T-65
I-Grips . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .T-66
Adapters for Multi-Pin Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .T-67
Strain Relief Grips for Liquidtight Conduit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .T-68
Technical Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .T-71
Cord Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .T-81
Straight Male Cord Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .T-82
45° Male Cord Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .T-85
90° Male Cord Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .T-86
Straight Female and Underground Feeder . . . . . . . . . . . . . . . . . . . . . . . . . . . . .T-87
Low Profile N .P .T ., PG and Metric Thread Connectors . . . . . . . . . . . . . . . . . . . .T-88
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .T-89
Hubbell Juniors® Miniature Nylon Cord Connectors . . . . . . . . . . . . . . . . . . . . . .T-90
Cord Connectors Technical Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .T-92
Hubbell Juniors® Technical Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .T-102
PolyTuff® Non-Metallic Liquidtight Conduit and Tubing . . . . . . . . . . . . . . . . . .T-104
PolyTuff® Non-Metallic Liquidtight Fittings . . . . . . . . . . . . . . . . . . . . . . . . . . . . .T-106
Metallic Liquidtight Conduit Fittings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .T-108
Technical Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .T-110
Kellems® Wire Management Products
Section T
T-1
Kellems® Wire Management Products
Wire Management Products
Kellems® Wire Mesh Grips Diagram
Bus Drop
Support Grip
Flexible
Conduit Grip
Support Grip
Support Grip
INDUSTRY
Deluxe
Cord Grip
Flexible
Conduit
Grip
Strain
Relief
Grip
To help you fully visualize the variety of uses available to you through Hubbell-Kellems
Mesh Grips, we have prepared this diagram of common applications . It follows the
typical pattern of usage you would find traveling from utility to industrial, commercial
and residential environments .
Pulling Grips are instrumental in the installations of transmission lines, service lines
and cabling for construction and maintenance .
Support Grips provide holding management for indoor and outdoor permanent
cable installations .
Kellems® Wire Mesh Grips Diagram
Strain Relief Grips are most often used to provide maximum reliability and minimum
maintenance in areas where cords on machinery or equipment is impacted by motion
or vibration or at risk of damage from cable pullout .
Beyond the electrical applications illustrated here, Hubbell-Kellems Mesh Grips can
be used for wire management on radio and microwave communications towers,
crane and hoist wire rope maintenance, elevator cable management and more .
Support Grip
Conduit
Support Grip
UTILITY
T-2
www.hubbell-wiring.com
Dimensions in Inches (cm)
Kellems® Wire Management Products
Overhead
Pulling Grip
UTILITY
Bus Drop
Support Grip
Deluxe Cord Grip
Bus Drop
Support Grip
Underground
Pulling Grip
INDUSTRY
Hose Containment Grip
Strain Relief Grip
Conduit Support
Kellems® Wire Mesh Grips Diagram
Support Grip
Underground
Pulling Grip
COMMERCIAL
Dimensions in Inches (cm)
RESIDENTIAL
www.hubbell-wiring.com
T-3
Kellems® Wire Management Products
Kellems® Wire Management Products
Quick Reference Selection Guide for Grip Applications
Pulling Grips
Heavy-Duty
Rotating Eye
For underground
wiring and overhead heavy-duty
pulling of service
lines and new
construction cable .
See pages T-7
and T-8 .
Slack Grips
For removing
underground
cable and pulling
slack in existing
cable and new
installations and
when end of cable
is not available .
See pages T-10
and T-11 .
Heavy-Duty
Flexible Eye
For overhead
transmission and
distribution line
stringing . See
pages T-6, T-7,
and T-9 .
Light-Duty
Flexible Eye
For light industrial
pulling of electrical cable and for
underground and
industrial plant
wiring and
re-wiring . See
page T-12 .
Quick Reference Selection Guide for Grip Applications
Support Grips
Single Eye
For single hook
attachment
of permanent
indoor/outdoor
cable . Available
on heavy-duty,
standard duty,
and service drop
grips . See pages
T-30, T-34, and
T-36 .
Support Grips
Wide Range
Bus Drop
Used indoors for
cable support
where flexible
cable connects
electrical
equipment to bus
duct . Support air
hose and water
hose . See page
T-38 .
Double Eye
For double hook
attachment of
permanent indoor/
outdoor cable .
Available on
heavy-duty and
standard duty
grips . See pages
T-31 and T-35 .
Single Offset Eye
For offset hook
attachment of
permanent indoor/
outdoor cable .
Available on
standard duty and
light-duty support
grips . See page
T-32 .
Universal Eye
Used to fasten
around a
structure or
closed loop .
Available on
standard duty
support and light
or heavy duty
service drop
grips . See pages
T-33 and T-37 .
Strain Relief Grips
Deluxe Cord
Indoor or outdoor
use where subject
to moisture, splash,
or washdown .
Examples are
enclosures, crane
hoist and pendant
drop stations,
hand tools, pumps,
and processing
equipment . Available
in straight, 90°, or
45° configurations .
See pages T-60 to
T-64 .
Dust-Tight
Strain Relief
Indoor use only for
wiring of electrical
enclosures,
machine tools,
portable power
tools, bus drop
cable systems .
See page T-65 .
Liquid-Tight, Flexible
Metal Conduit
Wiring of machine
tools, electrical
enclosures, motors,
and systems
subjected to vibration,
flexure, motion, or
strain . Available in
straight, 90°, or 45°
configurations . See
pages T-68 to T-70 .
Other Specialty Grips
Splicing Grips
Used as temporary splice for cable and wire rope, or as
reinforcement to protect cables and hoses . See pages
T-13 and T-14 .
Specifications are subject to change without notice.
T-4
Conduit Riser Grips
Ideal for supporting electrical wires inside rigid conduit via
a supporting ring . See pages T-39 to T-41 .
Hose Containment Grips
Used on flexible hose lines to prevent violent whipping of
hose in the event of failure at the fitting . See page T-58 .
www.hubbell-wiring.com
Dimensions in Inches (cm)
Kellems® Wire Management Products
Kellems® Wire Management Products
Pulling Grips
Overhead, Underground, Commercial Construction, Specialty
Flexible or rotating eyes will mate easily with line stringing swivels
for attachment to pulling lines; they have great strength for
trouble free pulling jobs
Shoulder protectors contain the cable inside the grip and smooth
the passage of the grip over line stringing blocks or conduit bends;
they protect the leading edge of the grip from abrasion
The galvanized steel mesh grip provides strength for secure pulling
jobs and a slim profile with little build-up; it has flexibility to follow
cable path
The multiweave styles available add strength for big pulling jobs
and provide positive gripping power
Endless weave allows easy installation onto cable . It has a snag-free
low profile; designed to be a reusable tool
Pulling Grips
Dimensions in Inches (cm)
www.hubbell-wiring.com
T-5
Kellems® Wire Management Products
Kellems® Wire Management Products
Overhead DUA-PULL® Pulling Grips
Flexible Eye, Double Weave Mesh, Galvanized Steel
WARNING!
It is important that you read
all breaking strength, safety
and technical data relating
to this product on pages
T-17 through T-27 .
DUA-PULL® Grips
DUA-PULL Pulling Grips are the highest strength pulling grips manufactured for
overhead transmission line stringing applications . They have a dual function, not
provided by any other grip, of working with both bare and insulated conductors
and synthetic rope .
DUA-PULL® Grips
Diameter Range
Conductor
Diameter
Inches (cm)
Rope*
Diameter
Inches (cm)
Approx.
Breaking
Strength
Lbs. (N)
E
In. (cm)
M
In. (cm)
Eye B
Diameter
In. (cm)
Over Cable
& Grip**
In. (cm)
Diameter
Color
Code
Catalog
Number
033271037
.19"- .37" ( .48- .94)
.25"- .65" ( .63-1 .65)
6,500 (28,912)
10" (25 .40)
24" (60 .96)
.220" ( .56)
.200" ( .51)
Black
.38"- .62" ( .97-1 .57)
.50"- .90" (1 .27-2 .29)
14,000 (62,272)
12" (30 .48)
36" (91 .44)
.375" ( .95)
.280" ( .71)
Dk Green 033271038
.63"- .87" (1 .60-2 .21)
.75"-1 .10" (1 .90-2 .79)
20,000 (88,960)
13" (33 .02)
48" (121 .92) .437" (1 .11) .360" ( .91)
.88"-1 .12" (2 .24-2 .84)
1 .00"-1 .50" (2 .54-3 .81)
30,600 (136,109)
15" (38 .10)
60" (152 .40) .500" (1 .27) .500" (1 .27) Dk Blue
Red
033271039
033271040
1 .13"-1 .37" (2 .87-3 .48)
1 .25"-1 .70" (3 .17-4 .32)
46,800 (208,166)
18" (45 .72)
76" (193 .04) .625" (1 .59) .625" (1 .59) Yellow
033271041
1 .38"-1 .90" (3 .51-4 .38)
1 .50"-2 .10" (3 .81-5 .33)
66,500 (295,792)
24" (60 .96)
89" (226 .06) .750" (1 .90) .750" (1 .90) Alum .
033271042
Overhead DUA-PULL® Pulling Grips
Note: E- Eye length.
M-Mesh length at nominal diameter.
* For rope, select smallest size grip which meets required work load.
** Add to cable or rope diameter.
DUA-PULL® Feed Tube
For Use with
DUA- PULL Grip
T-6
Rope Diameter
Inches (cm)
Feed Tube Length
Inches (cm)
Catalog
Number
033271037
.25"- .65" ( .63-1 .65)
28" (71 .12)
091061043
033271038
.50"- .90" (1 .27-2 .29)
40" (101 .60)
091061044
033271039
.75"-1 .10" (1 .90-2 .79)
52" (132 .08)
091061045
033271040
1 .00"-1 .50" (2 .54-3 .81)
67" (170 .18)
091061046
033271041
1 .25"-1 .70" (3 .17-4 .32)
83" (210 .82)
091061047
033271042
1 .50"-2 .10" (3 .81-5 .33)
96" (243 .84)
091061048
www.hubbell-wiring.com
Dimensions in Inches (cm)
Overhead Multiple Strength Pulling Grips
Flexible or Rotating Eye, Triple, Double, Single Weave, Galvanized Steel
Multiple Strength Style Grips
Multiple Strength Pulling Grips are designed for pulling aluminum or
copper bare conductor, ground wires, messenger strands, wire rope
and insulated cables .
WARNING!
It is important that you read
all breaking strength, safety
and technical data relating
to this product on pages
T-17 through T-27 .
Kellems® Wire Management Products
Kellems® Wire Management Products
Multiple Strength Grip-Rotating Eye
Cable Diameter
Range Inches (cm)
Approx. Breaking
Strength Lbs. (N)
E
Inches (cm)
M
Inches (cm)
Rotating Eye
Dia. Inches (cm)
Color
Code
Catalog
Number
.25"- .49" ( .63-1 .24)
.50"- .74" (1 .27-1 .88)
.75"- .99" (1 .90-2 .51)
1 .00"-1 .24" (2 .54-3 .15)
1 .25"-1 .49" (3 .17-3 .78)
1 .50"-1 .74" (3 .81-4 .42)
1 .75"-2 .24" (4 .44-5 .69)
2 .00"-2 .49" (5 .08-6 .32)
2 .50"-2 .99" (6 .35-7 .59)
3 .00"-3 .49" (7 .62-8 .86)
3 .50"-3 .99" (8 .89-10 .13)
6,800 (20,567)
10,000 (44,480)
14,400 (64,051)
24,600 (109,420)
30,600 (136,109)
30,600 (136,109)
48,000 (213,504)
48,000 (213,504)
48,000 (213,504)
48,000 (213,504)
48,000 (213,504)
5" (12 .70)
6" (15 .24)
6" (15 .24)
8" (20 .32)
8" (20 .32)
9" (22 .86)
10" (25 .40)
10" (25 .40)
10" (25 .40)
10" (25 .40)
10" (25 .40)
26" (66 .04)
32" (81 .28)
41" (104 .14)
52" (132 .08)
56" (142 .24)
60" (152 .40)
70" (177 .80)
50" (127 .00)
52" (132 .08)
54" (137 .16)
58" (142 .24)
⁷⁄₈" (2 .22)
1" (2 .54)
1" (2 .54)
1³⁄₈" (3 .49)
1⁵⁄₈" (4 .13)
1⁷⁄₈" (4 .76)
1⁷⁄₈" (4 .76)
1⁷⁄₈" (4 .76)
1⁷⁄₈" (4 .76)
1⁷⁄₈" (4 .76)
1⁷⁄₈" (4 .76)
Dark Green
Brown
Light Blue
Gold
Black
Red
Dark Blue
Yellow
Orange
Aluminum
Light Green
03302016
03302018
03302020
03302022
03302024
03302026
03302028
03302066
03302097
033021030
033021031
Note: E- Eye length.
M-Mesh length at nominal diameter.
Cable Diameter
Range Inches (cm)
Approx. Breaking
Strength Lbs. (N)
E
Inches (cm)
M
Inches (cm)
A-Eye
Dia. Inches (cm)
Color
Code
Catalog
Number
.25"- .49" ( .63-1 .24)
.50"- .74" (1 .27-1 .88)
.75"- .99" (1 .90-2 .51)
1 .00"-1 .24" (2 .54-3 .15)
1 .25"-1 .49" (3 .17-3 .78)
1 .50"-1 .74" (3 .81-4 .42)
1 .75"-2 .24" (4 .44-5 .69)
2 .00"-2 .49" (5 .08-6 .32)
2 .50"-2 .99" (6 .35-7 .59)
3 .00"-3 .49" (7 .62-8 .86)
3 .50"-3 .99" (8 .89-10 .13)
6,800 (20,567)
10,000 (44,480)
14,400 (64,051)
24,600 (109,420)
30,600 (136,109)
30,600 (136,109)
48,000 (213,504)
48,000 (213,504)
48,000 (213,504)
48,000 (213,504)
48,000 (213,504)
9" (22 .86)
9" (22 .86)
11" (27 .94)
12" (30 .48)
12" (30 .48)
12" (30 .48)
18" (45 .72)
18" (45 .72)
18" (45 .72)
18" (45 .72)
18" (45 .72)
26" (66 .04)
32" (81 .28)
41" (104 .14)
52" (132 .08)
56" (142 .24)
60" (152 .40)
70" (177 .80)
50" (127 .00)
52" (132 .08)
54" (137 .16)
58" (142 .24)
¹⁄₄" ( .63)
⁵⁄₁₆" ( .79)
³⁄₈" ( .95)
¹₂" (1 .27)
¹₂" (1 .27)
¹₂" (1 .27)
⁵⁄₈" (1 .59)
⁵⁄₈" (1 .59)
⁵⁄₈" (1 .59)
⁵⁄₈" (1 .59)
⁵⁄₈" (1 .59)
Dark Green
Brown
Light Blue
Gold
Black
Red
Dark Blue
Yellow
Orange
Aluminum
Light Green
03302044
03302046
03302048
03302050
03302052
03302054
03302056
033021078
033021079
033021080
033021081
Note: E- Eye length.
M-Mesh length at nominal diameter.
Dimensions in Inches (cm)
www.hubbell-wiring.com
T-7
Overhead Multiple Strength Pulling Grips
Multiple Strength Grip-Flexible Eye
Kellems® Wire Management Products
Kellems® Wire Management Products
Underground K-Type Pulling Grips
Rotating Eye, Double Weave, Galvanized Steel
WARNING!
It is important that you read
all breaking strength, safety
and technical data relating
to this product on pages
T-17 through T-27 .
K-Type Grips
Kellems® Rotating Eye, K-Type Pulling Grips are made of high strength
galvanized steel strand . All Grips feature double weave mesh for greater
strength and added mesh contact on the table, to handle longer or heavier
pulling jobs . The forged eye mates easily with a swivel or shackle .
K-Type Grips
Cable Diameter
Range Inches (cm)
Approx. Breaking
Strength Lbs. (N)
E
In. (cm)
M
In. (cm)
Rotating Eye
Diameter
Inches (cm)
Catalog Number
5,600 (24,909)
6,800 (30,246)
6,800 (30,246)
12,800 (56,934)
12,800 (56,934)
16,400 (72,941)
27,200 (120,986)
33,000 (146,784)
41,000 (182,368)
48,000 (213,504)
48,000 (213,504)
5" (12 .70)
5" (12 .70)
6" (15 .24)
7" (17 .78)
7" (17 .78)
7" (17 .78)
8" (20 .32)
10" (25 .40)
10" (25 .40)
10" (25 .40)
10" (25 .40)
11" (27 .94)
11" (27 .94)
20" (50 .80)
20" (50 .80)
21" (53 .34)
25" (63 .50)
26" (66 .04)
28" (71 .12)
30" (76 .20)
32" (81 .28)
33" (83 .82)
⁷⁄₈" (2 .22)
⁷⁄₈" (2 .22)
1" (2 .54)
1³⁄₈" (3 .49)
1³⁄₈" (3 .49)
1³⁄₈" (3 .49)
1⁵⁄₈" (4 .13)
1⁷⁄₈" (4 .76)
1⁷⁄₈" (4 .76)
1⁷⁄₈" (4 .76)
1⁷⁄₈" (4 .76)
03301001
03301002
03301013
03301014
03301016
03301017
03301018
03301019
03301020
03301021
033011017
5,600 (24,909)
6,800 (30,246)
9,600 (42,701)
16,400 (72,947)
16,400 (72,947)
27,200 (120,986)
33,000 (146,784)
41,000 (182,368)
48,000 (213,504)
48,000 (213,504)
48,000 (213,504)
40,000 (177,920)
54,000 (240,192)
5" (12 .70)
5" (12 .70)
6" (15 .24)
7" (17 .78)
7" (17 .78)
9" (22 .86)
10" (25 .40)
10" (25 .40)
10" (25 .40)
10" (25 .40)
10" (25 .40)
10" (25 .40)
10" (25 .40)
16" (40 .64)
16" (40 .64)
32" (81 .28)
33" (83 .82)
34" (86 .36)
36" (91 .44)
38" (96 .52)
39" (99 .06)
41" (104 .14)
42" (106 .68)
58" (147 .32)
60" (152 .40)
66" (167 .64)
⁷⁄₈" (2 .22)
⁷⁄₈" (2 .22)
1" (2 .54)
1³⁄₈" (3 .49)
1³⁄₈" (3 .49)
1⁵⁄₈" (4 .13)
1⁷⁄₈" (4 .76)
1⁷⁄₈" (4 .76)
1⁷⁄₈" (4 .76)
1⁷⁄₈" (4 .76)
1⁷⁄₈" (4 .76)
1⁷⁄₈" (4 .76)
1⁷⁄₈" (4 .76)
03301011
03301012
03301024
03301025
03301026
03301027
03301028
03301029
03301030
03301031
03301039
03301047
03301045
Short
Underground K-Type Pulling Grips
.50"- .62" (1 .27-1 .57)
.63"- .74" (1 .60-1 .88)
.75"- .99" (1 .90-2 .51)
1 .00"-1 .24" (2 .54-3 .15)
1 .25"-1 .49" (3 .17-3 .78)
1 .50"-1 .99" (3 .81-5 .05)
2 .00"-2 .49" (5 .08-6 .32)
2 .50"-2 .99" (6 .35-7 .59)
3 .00"-3 .49" (7 .62-8 .86)
3 .50"-3 .99" (8 .89-10 .13)
4 .00"-4 .49" (10 .16-11 .40)
Standard
.50"- .62" (1 .27-1 .57)
.63"- .74" (1 .60-1 .88)
.75"- .99" (1 .90-2 .51)
1 .00"-1 .49" (2 .54-3 .78)
1 .50"-1 .99" (3 .81-5 .05)
2 .00"-2 .49" (5 .08-6 .32)
2 .50"-2 .99" (6 .35-7 .59)
3 .00"-3 .49" (7 .62-8 .86)
3 .50"-3 .99" (8 .89-10 .13)
4 .00"-4 .49" (10 .16-11 .40)
4 .50"-4 .99" (11 .43-12 .67)
5 .00"-5 .99" (12 .70-15 .21)
6 .00"-6 .99" (15 .24-17 .75)
Note: E- Eye length.
M-Mesh length at nominal diameter.
See page T-26 for multiple cables in a single pulling grip.
T-8
www.hubbell-wiring.com
Dimensions in Inches (cm)
Underground T-Type Pulling Grips
Flexible Eye, Double Weave, Galvanized Steel
T-Type Grips
Kellems®
Flexible T-Type Pulling Grips are made of high strength galvanized
steel strand . They feature double weave mesh for positive holding power in
medium to heavy pulling jobs . The grip eye will easily attach to a swivel .
WARNING!
It is important that you read
all breaking strength, safety
and technical data relating
to this product on pages
T-17 through T-27 .
Kellems® Wire Management Products
Kellems® Wire Management Products
T-Type Grips
Cable Diameter
Range Inches (cm)
Approx. Breaking
Strength Lbs. (N)
E
Inches (cm)
M
Inches (cm)
Catalog Number
4,500 (20,016)
5,600 (24,909)
6,800 (30,246)
9,600 (42,701)
16,400 (72,947)
18,500 (82,288)
24,500 (108,976)
24,500 (108,976)
31,000 (137,888)
8" (20 .32)
8" (20 .32)
9" (22 .86)
9" (22 .86)
11" (27 .94)
12" (30 .48)
12" (30 .48)
14" (35 .56)
14" (35 .56)
21" (53 .34)
24" (60 .96)
24" (60 .96)
24" (60 .96)
24" (60 .96)
24" (60 .96)
24" (60 .96)
24" (60 .96)
26" (66 .04)
033041082
033041083
033041084
033041085
033041086
033041087
033041088
033041089
033041090
6,800 (30,246)
9,600 (42,701)
16,400 (72,947)
18,500 (82,288)
24,500 (108,976)
24,500 (108,976)
31,000 (137,888)
9" (22 .86)
9" (22 .86)
11" (27 .94)
12" (30 .48)
12" (30 .48)
14" (35 .56)
14" (35 .56)
36" (91 .44)
36" (91 .44)
36" (91 .44)
36" (91 .44)
36" (91 .44)
36" (91 .44)
40" (101 .60)
033041091
033041092
033041093
033041094
033041095
033041096
033041097
Short
.50"- .62" (1 .27-1 .57)
.63"- .74" (1 .60-1 .88)
.75"- .99" (1 .90-2 .51)
1 .00"-1 .49" (2 .54-3 .78)
1 .50"-1 .99" (3 .81-5 .05)
2 .00"-2 .49" (5 .08-6 .32)
2 .50"-2 .99" (6 .35-7 .59)
3 .00"-3 .49" (7 .62-8 .86)
3 .50"-3 .99" (8 .89-10 .13)
Standard
Note: E- Eye length.
M-Mesh length at nominal diameter.
See page T-26 for multiple cables in a single pulling grip.
Dimensions in Inches (cm)
www.hubbell-wiring.com
T-9
Underground T-Type Pulling Grips
.75"- .99" (1 .90-2 .51)
1 .00"-1 .49" (2 .54-3 .78)
1 .50"-1 .99" (3 .81-5 .05)
2 .00"-2 .49" (5 .08-6 .32)
2 .50"-2 .99" (6 .35-7 .59)
3 .00"-3 .49" (7 .62-8 .86)
3 .50"-3 .99" (8 .89-10 .13)
Kellems® Wire Management Products
Special Purpose Pulling Grips
Kellems® Wire Management Products
Special Purpose Pulling Grips
Non-Conductive and Slack Pulling
WARNING!
It is important that you read
all breaking strength, safety
and technical data relating
to this product on pages
T-17 through T-27 .
Non-Conductive Grips, Single Eye, Double Weave, Non-Metallic
Kellems® Non-Conductive
Pulling Grips, made of a high
strength, non-conductive
aramid fiber, are available for
pulling single cable or cable
bundles . Their braided double
weave design adds strength
and positive holding power .
Slack Pulling Grips are offered
in three styles made of
galvanized steel . The closed
type is used when the cable
end is accessible . When not
accessible, there are split lace
and split rod closing styles .
All grips feature a single offset
eye for easy attachment to a
pulling line .
Cable Diameter
Range Inches (cm)
Approx.
Breaking
Strength
Lbs. (N)
.50"- .62" (1 .27-1 .57)
4,000 (17,792) 5 .5" (13 .97) 24" (60 .96)
.44" (1 .12) Green
03628001
.63"- .74" (1 .60-1 .88)
5,000 (22,240) 5 .5" (13 .97) 26" (66 .04)
.44" (1 .12) Yellow
03628002
.75"- .99" (1 .90-2 .51)
6,000 (26,688) 6 .0" (15 .24) 31" (78 .74)
.63" (1 .60) Red
03628003
1 .00"-1 .24" (2 .54-3 .15) 6,000 (26,688) 6 .5" (16 .51) 36" (91 .44)
.63" (1 .60) Blue
03628004
E
In. (cm)
M
In. (cm)
A
In. (cm)
Color
Code
Catalog
Number
1 .25"-1 .49" (3 .17-3 .78) 6,000 (26,688) 6 .7" (17 .02) 41 .5" (105 .41) .63" (1 .60) White
03628005
1 .50"-1 .99" (3 .815 .05)
03628006
6,000 (26,688) 8 .0" (20 .32) 44 .0" (121 .76) .63" (1 .60) Pink
Slack Grip-Closed Mesh,
Offset Eye, Double Weave, Galvanized Steel
Cable Diameter
Range Inches (cm)
Approx. Breaking
Strength Lbs. (N)
E
Inches (cm)
M
Inches (cm)
Catalog
Number
Standard
.75"- .99" (1 .90-2 .51)
2,600 (11,565)
7" (17 .78)
12" (30 .48)
03308003
1 .00"-1 .24" (2 .54-3 .15)
4,000 (17,792)
8" (20 .32)
15" (38 .10)
03308004
1 .25"-1 .49" (3 .17-3 .78)
5,400 (24,019)
8" (20 .32)
16" (40 .64)
03308005
1 .50"-1 .74" (3 .81-4 .42)
6,600 (29,357)
8" (20 .32)
20" (50 .80)
03308006
1 .75"-1 .99" (4 .44-5 .05)
10,000 (44,480)
10" (25 .40)
18" (45 .72)
03308007
2 .00"-2 .49" (5 .08-6 .32)
11,000 (48,928)
10" (25 .40)
19" (48 .26)
03308008
2 .50"-2 .99" (6 .35-7 .59)
11,000 (48,928)
10" (25 .40)
20" (50 .80)
03308009
3 .00"-3 .49" (7 .62-8 .86)
14,500 (64,496)
12" (30 .48)
21" (53 .34)
03308010
3 .50"-3 .99" (8 .89-10 .13)
14,500 (64,496)
12" (30 .48)
22" (55 .88)
03308011
Note: E- Eye length.
M-Mesh length at nominal diameter.
See page T-26 for multiple cables in a single pulling grip.
T-10
www.hubbell-wiring.com
Dimensions in Inches (cm)
Special Purpose Pulling Grips
Slack Pulling
WARNING!
It is important that you read
all breaking strength, safety
and technical data relating
to this product on pages
T-17 through T-27 .
Slack Grip-Split Mesh, Rawhide Lace Closing,
Offset Eye, Double Weave, Galvanized Steel
Cable Diameter
Range Inches (cm)
Approx. Breaking
Strength Lbs. (N)
E
Inches (cm)
M
Inches (cm)
Catalog
Number
2,500 (11,120)
3,500 (15,568)
4,000 (17,792)
4,000 (17,792)
4,000 (17,792)
4,000 (17,792)
4,000 (17,792)
7" (17 .78)
8" (20 .32)
8" (20 .32)
9" (22 .86)
10" (25 .40)
10" (25 .40)
10" (25 .40)
12" (30 .48)
15" (38 .10)
16" (40 .64)
17" (43 .18)
18" (45 .72)
19" (48 .26)
20" (50 .80)
03309003
03309004
03309005
03309006
03309007
03309008
03309009
4,000 (17,792)
4,000 (17,792)
4,000 (17,792)
4,000 (17,792)
4,000 (17,792)
9" (22 .86)
10" (25 .40)
10" (25 .40)
12" (30 .48)
12" (30 .48)
25" (63 .50)
26" (66 .04)
29" (73 .66)
32" (81 .28)
35" (88 .90)
03309015
03309016
03309017
03309018
03309019
Standard
.75"- .99" (1 .90-2 .51)
1 .00"-1 .24" (2 .54-3 .15)
1 .25"-1 .49" (3 .17-3 .78)
1 .50"-1 .74" (3 .81-4 .42)
1 .75"-1 .99" (4 .44-5 .05)
2 .00"-2 .49" (5 .08-6 .32)
2 .50"-2 .99" (6 .35-7 .59)
Slack Pulling Grips are
offered in three styles made
of galvanized steel . The
closed type is used when
the cable end is accessible .
When not accessible, there
are split lace and split rod
closing styles . All grips
feature single offset eye
for easy attachment to a
pulling line .
Kellems® Wire Management Products
Kellems® Wire Management Products
Long
1 .50"-1 .99" (3 .81-5 .05)
2 .00"-2 .49" (5 .08-6 .32)
2 .50"-2 .99" (6 .35-7 .59)
3 .00"-3 .49" (7 .62-8 .86)
3 .50"-3 .99" (8 .89-10 .13)
Special Purpose Pulling Grips
Slack Grip-Split Mesh, Rod Closing,
Offset Eye, Single Weave, Galvanized Steel
Cable Diameter
Range Inches (cm)
Approx. Breaking
Strength Lbs. (N)
E
Inches (cm)
M
Inches (cm)
Catalog
Number
.50"- .61" (1 .27-1 .55)
.62"- .74" (1 .57-1 .88)
.75"- .99" (1 .90-2 .51)
1 .00"-1 .24" (2 .54-3 .15)
1 .25"-1 .49" (3 .17-3 .78)
1 .50"-1 .74" (3 .81-4 .42)
1 .75" -1 .99" (4 .44-5 .05)
2 .00"-2 .49" (5 .08-6 .32)
2 .50"-2 .99" (6 .35-7 .59)
3 .00"-3 .49" (7 .62-8 .86)
3 .50"-3 .99" (8 .89-10 .13)
1,500 (6,672)
1,800 (8,006)
2,200 (9,786)
3,400 (15,123)
4,500 (20,016)
5,800 (25,798)
7,600 (33,805)
9,000 (40,032)
11,000 (48,928)
12,000 (53,376)
12,000 (53,376)
7" (17 .78)
7" (17 .78)
7" (17 .78)
8" (20 .32)
8" (20 .32)
9" (22 .86)
10" (25 .40)
10" (25 .40)
10" (25 .40)
12" (30 .48)
12" (30 .48)
6" (15 .24)
8" (20 .32)
10" (25 .40)
12" (30 .48)
14" (35 .56)
15" (38 .10)
16" (40 .64)
19" (48 .26)
20" (50 .80)
21" (53 .34)
24" (60 .96)
03310001
03310002
03310003
03310004
03310005
03310006
03310007
03310008
03310009
03310010
03310011
Note: E- Eye length.
M-Mesh length at nominal diameter.
See page T-26 for multiple cables in a single pulling grip.
Dimensions in Inches (cm)
www.hubbell-wiring.com
T-11
Kellems® Wire Management Products
Kellems® Wire Management Products
Low Tension Pulling Grips
Flexible Eye, Single Weave, Galvanized Steel
WARNING!
It is important that you read
all breaking strength, safety
and technical data relating to
this product on pages T-17
through T-27 .
Light Duty Grips
Light Duty Pulling Grips are
made of galvanized steel in
a single weave construction .
They feature a flexible eye
for easy attachment to a
pulling line .
Cable Diameter
Range Inches (cm)
Approx. Breaking
Strength Lbs. (N)
E
Inches (cm)
M
Inches (cm)
Catalog
Number
2,800 (12,454)
2,800 (12,454)
4,000 (17,792)
5,300 (23,574)
5,300 (23,574)
6,800 (30,246)
8,500 (37,808)
8,500 (37,808)
5" (12 .70)
5" (12 .70)
6" (15 .24)
7" (17 .78)
7" (17 .78)
8" (20 .32)
9" (22 .86)
9" (22 .86)
11" (27 .94)
11" (27 .94)
12" (30 .48)
13" (33 .02)
14" (35 .56)
15" (38 .10)
17" (43 .18)
18" (45 .72)
03303001
03303002
03303003
03303004
03303005
03303006
03303007
03303008
2,800 (12,454)
2,800 (12,454)
4,000 (17,792)
6,800 (30,246)
6,800 (30,246)
6,800 (30,246)
8,500 (37,808)
10,600 (47,149)
14,700 (65,386)
14,700 (65,386)
5" (12 .70)
5" (12 .70)
6" (15 .24)
7" (17 .78)
7" (17 .78)
8" (20 .32)
9" (22 .86)
9" (22 .86)
10" (25 .40)
10" (25 .40)
16" (40 .64)
16" (40 .64)
20" (50 .80)
20" (50 .80)
21" (53 .34)
23" (58 .42)
25" (63 .50)
27" (68 .58)
30" (76 .20)
32" (81 .28)
03303010
03303011
03303012
03303013
03303015
03303016
03303017
03303018
03303019
03303029
Cable Diameter
Range Inches (cm)
Approx. Breaking
Strength Lbs. (N)
E
Inches (cm)
M
Inches (cm)
Model
Catalog
Number
.19"- .24" ( .48- .61)
.25"- .37" ( .63- .94)
.38"- .49" ( .97-1 .24)
.50"- .62" (1 .27-1 .57)
.63"- .74" (1 .60-1 .88)
.75"- .99" (1 .90-2 .51)
1 .00"-1 .24" (2 .54-3 .15)
400 (1,779)
450 (2,002)
900 (4,003)
1,300 (5,782)
1,950 (8,674)
2,800 (12,454)
3,900 (17,347)
3¹⁄₄" (8 .25)
3¹⁄₄" (8 .25)
3³⁄₄" (9 .52)
4¹⁄₄" (10 .79)
5" (12 .70)
5³⁄₄" (14 .60)
6¹⁄₂" (16 .51)
4¹⁄₄" (10 .79)
4¹⁄₄" (10 .79)
7" (17 .78)
8¹⁄₂" (21 .59)
10" (25 .40)
10" (25 .40)
11¹⁄₂" (29 .21)
J19
J25
J37
J50
J62
J75
J100
03305011*
03305001
03305002
03305003
03305004
03305005
03305006
Short
.50"- .62" (1 .27-1 .57)
.63"- .74" (1 .60-1 .88)
.75"- .99" (1 .90-2 .51)
1 .00"-1 .24" (2 .54-3 .15)
1 .25"-1 .49" (3 .17-3 .78)
1 .50"-1 .74" (3 .81-4 .42)
1 .75"-1 .99" (4 .44-5 .05)
2 .00"-2 .49" (5 .08-6 .32)
Standard
Junior Pulling Grips feature a
strong galvanized steel, single
weave mesh . A flexible eye
easily attaches to a pulling
line, snake or fish tape .
.50"- .62" (1 .27-1 .57)
.63"- .74" (1 .60-1 .88)
.75"- .99" (1 .90-2 .51)
1 .00"-1 .24" (2 .54-3 .15)
1 .25"-1 .49" (3 .17-3 .78)
1 .50"-1 .99" (3 .81-5 .05)
2 .00"-2 .49" (5 .08-6 .32)
2 .50"-2 .99" (6 .35-7 .59)
3 .00"-3 .49" (7 .62-8 .86)
3 .50"-3 .99" (8 .89-10 .13)
Low Tension Pulling Grips
Junior Grip Kit
Junior Grip Kit contains 6 grips,
one of each size . Catalog number
033051114 .
Junior Pulling Grips
Note: See page T-26 for multiple
cables in a single pulling grip.
See page T-27 for building
wire selection chart.
T-12
Note: E- Eye length.
M-Mesh length at nominal diameter.
* Not included in Junior Grip Kit, 033051114.
www.hubbell-wiring.com
Dimensions in Inches (cm)
Wire Rope Splicing Grips
Triple, Double, Single Weave, Galvanized Steel
WARNING!
It is important that you read
all breaking strength, safety
and technical data relating
to this product on pages
T-17 through T-27 .
Regular Wire Rope Grips
Cable Diameter
Range Inches (cm)
Approx. Breaking
Strength Lbs. (N)
Approx. Length
Of Grip Feet (m)
Catalog
Number
⁹⁄₁₆"- ⁵⁄₈" (1 .43-1 .59)
7,500 (33,360)
5 .75 (1 .75)
03316001
³⁄₄"- ⁷⁄₈" (1 .90-2 .22)
12,500 (55,600)
6 .75 (1 .90)
03316002
1"-1¹⁄₈" (2 .54-2 .86)
16,000 (71,168)
7 .00 (2 .13)
03316003
1¹⁄₄"- 1³⁄₈" (3 .17-3 .49)
20,000 (88,960)
8 .00 (2 .44)
03316004
1³⁄₈"- 1¹⁄₂" (3 .49-3 .81)
20,000 (88,960)
8 .00 (2 .44)
03316006
Kellems® Wire Rope Grips
are made of high strength
galvanized steel strand in
a construction of triple,
double and single weave
for superior gripping ability .
They are available with or
without a rotating barrel
which will help eliminate
twist in the old rope from
being transferred to the
new rope .
Kellems® Wire Management Products
Kellems® Wire Management Products
Rotating Wire Rope Grips
Approx. Breaking
Strength Lbs. (N)
Approx. Length
Of Grip Feet (m)
Barrel Dimensions
Lgth. x O.D. In. (cm)
Catalog
Number
⁷⁄₁₆"- ¹⁄₂" (1 .11-1 .27)
5,000 (22,240)
5 .33 (1 .63)
3 .00" (7 .62) x .87" (2 .21)
03317001
⁹⁄₁₆"- ⁵⁄₈" (1 .43-1 .59)
7,500 (33,360)
5 .83 (1 .78)
4 .25" (10 .79) x 1 .00" (2 .54) 03317002
³⁄₄"- ⁷⁄₈" (1 .90-2 .22)
12,500 (55,600)
6 .50 (1 .98)
4 .25" (10 .79) x 1 .00" (2 .54) 03317003
1"- 1¹⁄₈" (2 .54-2 .86)
16,000 (71,168)
8 .67 (2 .64)
5 .50" (13 .97) x 1 .37" (3 .48) 03317004
1¹⁄₄"- 1³⁄₈" (3 .17-3 .49) 20,000 (88,960)
9 .00 (2 .74)
5 .50" (13 .97) x 1 .37" (3 .48) 03317005
1¹⁄₂"- 1³⁄₄" (3 .81-4 .44) 20,000 (88,960)
11 .00 (3 .35)
5 .50" (13 .97) x 1 .37" (3 .48) 03317006
Dimensions in Inches (cm)
www.hubbell-wiring.com
Wire Rope Splicing Grips
Cable Diameter
Range Inches (cm)
T-13
Kellems® Wire Management Products
Kellems® Wire Management Products
Cable Splicing Grips
Double Weave, Galvanized Steel / Single Weave, Galvanized Steel
WARNING!
It is important that you read
all breaking strength, safety
and technical data relating
to this product on pages
T-17 through T-27 .
Splicing Grip
Splicing Grips are made of
galvanized steel in double weave
mesh construction . They are
available in various lengths and
sizes to suit most applications .
Double Weave Tube
Approx. Breaking Strength
Lbs. (N)
.37"- .49"
( .94-1 .24)
3,500
(15,568)
Mesh Length
Inches (cm)
Catalog Number
18" (45 .72)
24" (60 .96)
36" (91 .44)
48" (121 .92)
72" (182 .88)
013041330
—
—
—
—
Cable Diameter
Range Inches (cm)
.50"- .61"
(1 .27-1 .55)
3,500
(15,568)
.62"- .74"
(1 .57-1 .88)
4,400
(19,571)
.75"- .99"
(1 .90-2 .51)
7,500
(33,360)
1 .00"-1 .49"
(2 .54-3 .78)
10,000
(44,480)
01304064
01304011
—
—
—
01304009
01304013
013041234
—
—
—
01304010
01304054
01304017
01304037
—
01304015
01304055
01304029
013041333
Cable Splicing Grips
Junior Splicing Grips,
Single Weave
Junior Splicing Grips are made of
galvanized steel and are designed
for use in very light duty and small
splicing jobs .
Junior Tube
Cable Diameter
Range Inches (cm)
Approx. Breaking
Strength Lbs. (N)
Length @ Nom
Diameter Inches (cm)
Catalog Number
.18"- .24" ( .46- .61)
.25"- .36" ( .63- .91)
400 (1,779)
400 (1,779)
7" (17 .78)
8" (20 .32)
01301008
01301013
T-14
www.hubbell-wiring.com
Dimensions in Inches (cm)
Tools and Bands
Pulling Grips Accessories
Punch-Lok® Bands
Punch-Lok Bands are applied over the tail of a grip to prevent the mesh from being tripped or pulled loose .
Also, they assure full gripping action by locking the mesh of the tail in tight contact with the cable or rope .
Kellems® Wire Management Products
Kellems® Wire Management Products
When the tail of a grip is the leading end, the bands are particularly important to prevent accidental release
caused by tripping on obstructions . A conductor-to-conductor (double-socking) pulling operation is a good
example: where two grips connect two conductors to form a temporary splice . Bands should be applied to
the ends of the grips as illustrated herein . It is also common practice to tape over the banded tail area to
assure smooth passage through the sheaves .The conductor should be installed in the grip up to the elbows
of the aluminum shoulders in order to assure full and complete gripping action .
Punch-Lok Bands
Grip Banding
Range Inches (cm)
Band Width
Inches (cm)
Band Inside
Diameter Inches (cm)
Model
Catalog Number
¹⁄₄"-1¹⁄₈" ( .63-2 .86)
1¹⁄₈"-1⁵⁄₈" (2 .86-4 .13)
1⁵⁄₈"-2¹⁄₄" (4 .13-5 .71)
2¹⁄₄"-3¹⁄₂" (5 .71-8 .89)
3¹⁄₂"-5" (8 .89-12 .70)
³⁄₈" ( .95)
³⁄₈" ( .95)
⁵⁄₈" (1 .59)
⁵⁄₈" (1 .59)
⁵⁄₈" (1 .59)
1³⁄₈" (3 .49)
2" (5 .08)
2¹⁄₂" (6 .35)
4" (10 .16)
6" (15 .24)
0-311
0-316
0-10
0-16
0-24
20320050
20320051
20320052
20320053
20320054
Accessories
Punch-Lok Tools
Catalog Number
P-1000 for use with ⁵⁄₈" width Banding tool .
P-38 for use with ³⁄₈" and ⁵⁄₈" width Banding tool for tight spaces .
20320048
20320047
Tools and Bands
Description
Note: In all cases two Punch-Lok Bands should be double wrapped approximately one inch to two inches (2.54cm to 5.08cm) from the grip’s tail.
Banding is required to ensure maximum reliability and guard against accidental release.
Punch-Lok ® is a registered trademark of Punch-Lok Inc.
Dimensions in Inches (cm)
www.hubbell-wiring.com
T-15
Kellems® Wire Management Products
Kellems® Wire Management Products
Swivels
Pulling Grips Accessories
WARNING!
It is important that you read
all breaking strength, safety
and technical data relating
to this product on pages
T-17 through T-27 .
20308001A
Stainless Steel Swivels
Swivels are essential to the efficiency and safety of any high tension application . They are particularly
important where continuous pulls develop higher and higher torque levels . Torque is intensified by the
pull-resistance of the cable itself and the resistance of the high tension controlling equipment regulating
line sag . Ball bearing swivels release torque and prevent it from reaching dangerous levels that can
damage the cable and obstruct the lines .
C
B
A
E
D
F
G
Stainless Steel Swivels
Maximum Safe
Working Load
Lbs. (N)
A
B
Dimensions in Inches (cm)
C
D
E
F
G
Model
Catalog
Number
2,250 (10,000)
5,000 (22,240)
9,000 (40,030)
10,000 (44,480)
30,000 (133,440)
⁷⁄₈" (2 .22)
1¼" (3 .17)
1½" (3 .81)
1⁵⁄₈" (4 .13)
2³⁄₈" (6 .03)
2½" (6 .35)
3¹¹⁄₁₆" (9 .37)
4¼" (10 .79)
4½" (11 .43)
7⁵⁄₈" (19 .37)
3³⁄₈" (8 .57)
4¾" (12 .06)
5⁵⁄₈" (14 .29)
6" (15 .24)
10" (25 .40)
³⁄₈" (0 .95)
1⁷⁄₃₂" (1 .35)
1⁹⁄₃₂" (1 .51)
¹¹⁄₁₆" (1 .75)
1¹⁄₃₂" (2 .62)
⁵⁄₁₆" (0 .79)
¹³⁄₃₂" (1 .03)
½" (1 .27)
⁵⁄₈" (1 .59)
⁷⁄₈" (2 .22)
³¹⁄₃₂" (2 .46)
1⁹⁄₃₂" (3 .25)
1⁹⁄₁₆" (3 .97)
1²³⁄₃₂" (4 .36)
2²⁵⁄₃₂" (7 .06)
A-13L
BB-13L
B-13L
C-13L
D-13L
20308001A
20308002A
20308003A
20308004A
20308005A
Swivels
⁷⁄₁₆" (1 .11)
1⁷⁄₃₂" (1 .35)
¹¹⁄₁₆" (1 .75)
¾" (1 .90)
1³⁄₁₆" (3 .02)
T-16
www.hubbell-wiring.com
Dimensions in Inches (cm)
Technical Information
Pulling Grips
Kellems Pulling Grips are reusable tools for pulling electrical cable, bare conductor or rope . They are easy and fast to
install, providing the user with a smooth, slim profile that allows for easy passage through ducts, conduit, blocks and
sheaves . Kellems Pulling Grips are made of the highest quality galvanized steel strand which assures the user of a long
lasting grip . There is a Kellems Pulling Grip for every pulling job .
CAUTION: It is very important to comply with all of the following precautions . Failure to do so may result in property
damage, personal injury or death .
1 . Pulling grips are to be installed by a qualified individual in accordance with all applicable national
and local safety, electrical and rigging codes .
2 . Ensure that the correct grip is selected for your specific needs .
3 . Do not use a pulling grip for any application other than pulling cable .
4 . Thoroughly examine the grip for damage . Do not use a damaged grip .
5 . Ensure that the recommended work load of the grip is suitable for the application . Never use grips
at their approximated rated breaking strength . A safety factor of 5 is recommended for pulling grips .
6 . Do not alter grips in any way . For example, do not modify pulling eyes, shoulders, fittings or lugs .
7 . Do not attach any type of pulling hardware to any point on the grip other than the pulling eye .
The pulling eye is the only acceptable means of attachment to external hardware .
8 . Always apply 2 bands at 1" and 2" respectively, from the tail end of the mesh to guard against
accidental release of the grip . Accidental release can occur if an object contracts and pushes
against the tail end of the mesh, thereby expanding and releasing its hold .
Kellems® Wire Management Products
Kellems® Wire Management Products
Select The Correct Pulling Grip
Each Kellems Grip is designed to work on a specific range of cable diameters .
Step 1 Refer to the chart below to determine the style of grip best suited for your application .
Step 2 Determine your cable outside diameter .
Step 3 Find the grip size that encompasses your cable diameter .
Step 4 Estimate the tension to be put on the grip, establish the working load you require and compare this
to the listed approximate breaking strength of the grip to insure that the grip will be strong enough .
Refer to page T-18 for safety and working load factors .
Pulling Grip Selection Chart
Grip Style
Application
Page Number
DUA-PULL®, flexible eye
Dimensions in Inches (cm)
www.hubbell-wiring.com
T-6
T-7
T-7
T-8
T-9
T-10
T-10
T-11
T-11
T-12
T-12
T-13
T-14
T-15, T-16
T-50, T-51, T-52
T-17
Technical Information
Extra high strength overhead transmission line stringing for bare or
insulated conductor and synthetic rope .
Multiple strength, flexible eye Normal overhead transmission and distribution line stringing for bare or
insulated conductor .
Multiple strength, rotating eye Normal overhead transmission and distribution line stringing for bare or
insulated conductor .
K-type grip, rotating eye
Underground power cables and communication lines . Service lines into factories .
T-type grip, flexible eye
Underground power cables and communication lines . Service lines into factories .
Non-conductive, flexible eye
Pull insulated distribution cable into place .
Slack pulling, closed mesh
Remove underground cable . For pulling slack in final placement of new cable
when end of cable is available .
Slack pulling, split mesh,
Remove underground cable . For pulling slack in final placement of new cable
rawhide lace closing
when end of cable is not available .
Slack pulling, split mesh,
Remove underground cable . For pulling slack in final placement of new cable
rod closing
when end of cable is not available, with rod closing for quick installation .
Light duty, flexible eye
Light pulling, underground electrical construction . Industrial plant
wiring and rewiring jobs .
Junior, flexible eye
Connect bundled insulated building wire to a pulling tape . Pull wire through conduit .
Regular and rotating wire rope Restring wire rope in cranes and oil rigs .
Splicing
Temporary splice for cable or wire rope .
Pulling Grip Accessories
Tools, bands, swivels .
Fiber Optic Cable Pulling Grips Pull fiber optic cable into place overhead, underground or through duct and conduit .
Kellems® Wire Management Products
Kellems® Wire Management Products
Technical Information
Pulling Grips
Safety And Working Load Factors For Wire Mesh Grips
The broad application of Kellems grips on a wide
variety of objects requires that adequate safety
factors be used to establish working loads . The
approximate breaking strength of a Kellems grip
represents an average calculation based on data
established from actual direct tension testing done
in our engineering laboratories .
It is impossible to catalog or guarantee a safety
factor suitable for all applications as operating
conditions are never the same . The tension,
diameter, movement, number of objects gripped,
gripping surface, and the attachments used are just
some of the factors which vary with each application .
These factors, together with the effects of abrasion,
corrosion, prior use or abuse and any other variables
of a specific application, must be considered by the
user and the grip replaced as appropriate . Where the
conditions of the application are not well defined or
known, or where risk of injury to persons or property
is involved, a greater safety factor should be utilized .
Under normal conditions, Kellems’ recommended
factor of safety is five for catalog listed pulling
grips, and ten for catalog listed support grips.
Any warranty as to quality, performance or fitness for
use of grips is always premised on the condition that
the published breaking strengths apply only to new,
unused grips, and that such products are properly
stored, handled, used, maintained and inspected by
the user at a frequency appropriate for the use and
condition of the grip .
Examples
Grip Style
Approx. Breaking
Strength Lbs. (N)
Safety
Factor
Max. Rec.
Load Lbs. (N)
Catalog Number
Pulling Grips
Support Grips
27,200 (120,986)
1,610 (7,161)
5
10
5,440 (24,197)
161 (716)
03301027
02201018
The maximum recommended working load then is the tension to be exerted on the grip in application with a
margin of safety to take care of unforeseen and unusual circumstances .
It is the end-user’s decision to determine how much of a safety factor is acceptable for the application .
The metric unit of measure (force) for breaking strength and load is newtons (N) . To convert from newtons to
the metric unit of weight (kilograms) the conversion factor is 9 .808 newtons/kilogram .
Technical Information
Pulling Grip Materials
Material
Galvanized steel wire
Features
• High strength
• Not subject to continuous
outside environment
Non-metallic strand
• Superior flex life
• Non-conductive
• Corrosion resistant
• Moderate strength
Product Group
• Pulling grips
• Wire rope grips
• Splicing grips
• Non-conductive pulling grips
Approvals
UL and CSA Certification is indicated on appropriate product catalog pages .
T-18
www.hubbell-wiring.com
Dimensions in Inches (cm)
Technical Information
Pulling Grips
Overhead Pulling DUA-PULL® Grips
DUA-PULL Pulling Grips are the highest strength pulling grips manufactured for overhead transmission
line stringing applications . They have a dual function of working with both bare and insulated conductors
and synthetic rope, not provided by any other grip . Kellems’ patented two-over, two-under weave design
gives exceptional strength and gripping ability by putting more steel mesh in contact with the cable or
rope surfaces .
THIS IS THE ONLY PULLING GRIP RECOMMENDED FOR USE ON SYNTHETIC ROPE .
Application
The DUA-PULL Grips are primarily used in overhead transmission line construction where loads and safety
considerations require an extra high strength grip . They are most commonly used for attaching pulling lines
to conductors, conductors to running boards and “double socking" for conductor-to-conductor connections .
The DUA-PULL line accommodates ACSR, ACAR, all aluminum and copper conductors . Also, the grips
accommodate ground wires, messenger strands, wire ropes and synthetic ropes .
Kellems® Wire Management Products
Kellems® Wire Management Products
Benefits
•
•
•
•
•
Made of high strength galvanized steel strand.
Recommended for pulling bare or insulated conductor, wire rope and synthetic rope.
DUA-PULL mesh design offers the greatest holding power for all pulling applications.
Each grip size is color coded for fast and accurate identification and selection.
Will mate with swivels. See page T-16.
Feed Tubes
The Kellems Feed Tube is used when assembling synthetic rope into the DUA-PULL Grip . It is required on
the largest two sizes of DUA-PULL Grips . Feed Tubes are available for use on all size DUA-PULL Grips .
Benefits
• Saves time, allowing fast, easy assembly.
• Can be reused if not damaged.
Note: 1. Do not run grips or swivels over bullwheels while under tension.
2. Two Punch-Lok ® bands should be firmly attached approximately 1" and 2" (2.54cm and 5.08cm) from the grip’s tail.
Banding is required to ensure maximum reliability and guard against accidental release. See page T-15.
3. Double braided rope, such as 2-in-1 type, should be back spliced for approximately 2/3 of the mesh length for best gripping results.
Grip size should be selected by diameter of back splice.
Technical Information
Dimensions in Inches (cm)
www.hubbell-wiring.com
T-19
Kellems® Wire Management Products
Kellems® Wire Management Products
Technical Information
Pulling Grips
Overhead Pulling Multiple Strength Grips
Multiple Strength Pulling Grips are designed for pulling aluminum or copper bare conductor, ground wires,
messenger strands, wire rope and insulated cables . They are made of high strength galvanized steel strand
and feature a multi-weave mesh construction of single, double and triple weave for firm holding power .
Application
Kellems Multiple Strength Grips are ideal for overhead transmission and distribution line stringing where
moderate loading is anticipated . They are economical tools for attaching conductors to pulling lines and
double socking for conductor-to-conductor connections .
Rotating Eye Feature
Multiple Strength Grips are available with a forged steel rotating eye which can be attached to a swivel . The
forged eye is durable, compact and streamlined and will thread through blocks and sheaves without binding .
The rotating eye is not a swivel and will not turn while under tension; it can turn to relieve pulling torque when
tension is relaxed . If constant swivel action is required, a swivel should be used . For rotating eye dimensions,
see page T-21 . For swivels, see page T-16 .
Flexible Eye Feature
Multiple Strength Grips are also available with a flexible, patented wire rope eye . This compact eye will mate
with a swivel, and pass through blocks and sheaves without binding .
Benefits
• Economical, high strength pulling tool.
• Multi-weave construction provides greater strength and holding power.
• Endless Weave Grip end lies flat on the cable and will not snag.
Note: 1. Do not run grips or swivels over bullwheels while under tension.
Technical Information
2. Two Punch-Lok ® bands should be firmly attached approximately 1" and 2" (2.54cm and 5.08cm) from the grip’s tail.
Banding is required to ensure maximum reliability and guard against accidental release. See page T-15.
T-20
www.hubbell-wiring.com
Dimensions in Inches (cm)
Technical Information
Pulling Grips
Underground Pulling K-Type and T-Type Grips
K-Type Application
Rotating Eye, K-Type Pulling Grips are specially designed for use in the installation of underground power
cables, communication lines and service lines into factories, shopping centers, construction projects and
general underground electrical construction .
Rotating Eye Feature
K-Type Grips come equipped with a forged steel rotating eye which can be attached to a swivel . The forged
eye is durable, compact and streamlined, and will thread through blocks and sheaves without binding .
The rotating eye is not a swivel and will not turn while under tension; it can turn to relieve pulling
torque when the tension is relaxed . If constant swivel action is required, a swivel should be used . For
swivels, see page T-16 .
Kellems® Wire Management Products
Kellems® Wire Management Products
Benefits
• An economical tool for pulling cable.
• Safe, rugged and dependable.
• Equipped with a rotating eye for spin out
of pulling torque after load release .
• Easily installed and removed.
3/16 R.
B
F
C
A
Rotating Eye Dimensions
1/8 R.
Rotating Eye
Dimensions
Inches (cm)
A
B
C
D
F
⁷⁄₈" (2 .22)
1" (2 .54)
1³⁄₈" (3 .49)
1⁵⁄₈" (4 .13)
1⁷⁄₈" (4 .76)
⁷⁄₈" (2 .22)
1" (2 .54)
1³⁄₈" (3 .49)
1⁵⁄₈" (4 .13)
1⁷⁄₈" (4 .76)
⁹⁄₃₂" ( .71)
¹⁄₂" (1 .27)
¹⁄₂" (1 .27)
⁵⁄₈" (1 .59)
²¹⁄₃₂"(1 .67)
¹⁄₂" (1 .27)
⁹⁄₁₆" (1 .43)
¹¹⁄₁₆" (1 .75)
⁷⁄₈" (2 .22)
1" (2 .54)
⁷⁄₈" (2 .22)
¹³⁄₁₆" (2 .06)
1" (2 .54)
1³⁄₁₆" (3 .02)
1³⁄₈" (3 .49)
2⁵⁄₈" (6 .67)
3¹⁄₂" (8 .89)
4¹⁄₂" (11 .43)
5⁵⁄₁₆" (13 .49)
6¹⁄₈" (15 .56)
D
T-Type
Kellems Flexible T-Type Pulling Grips are made of high strength galvanized steel strand . They feature
double weave mesh for positive holding power in medium to heavy pulling jobs . The grip eye will easily
attach to a swivel .
Application
Benefits
•
•
•
•
•
Will pull a single cable or cable bundles.
Patented flexible eye design provides flexibility to follow line of pull.
A dependable, reusable pulling tool.
Easily installed and removed.
Mates easily with a swivel. See page T-16.
Dimensions in Inches (cm)
www.hubbell-wiring.com
T-21
Technical Information
T-Type Pulling Grips are used for the installation of underground power cables, communication lines and
service lines into factories, construction projects and for general underground electrical construction .
Available in two mesh lengths, short for medium pulls, and standard for general purpose pulling .
Kellems® Wire Management Products
Kellems® Wire Management Products
Technical Information
Pulling Grips
Special Purpose Grips
Non-Conductive Pulling Grips
Kellems Non-Conductive Pulling Grips, made of a high strength, non-conductive aramid fiber, are available
for pulling single cable or cable bundles . Their braided double weave design adds strength and positive
holding power .
Application
Kellems Non-Conductive Pulling Grips were developed for use by utilities for pulling overhead distribution
lines in close proximity to energized lines and hardware .
Benefits
•
•
•
•
•
Color coded for fast on-site selection.
Extra flexibility for easy installation.
Non-metallic mesh provides for safe pulls over “hot" areas.
Pellethane jacketed aramid fiber mesh resists abrasion.
Grips are corrosion resistant.
Note: Taping is required to guard against accidental release and to insure maximum reliability. Apply vinyl plastic electrical tape starting 2" to 3" (5.08cm to
7.62cm) from the tail of the grip onto 2" to 3" (5.08cm to 7.62cm) of cable.
Slack Pulling Grips
Slack Pulling Grips are offered in three styles made of galvanized steel . The closed type is used when the
cable end is accessible . When not, there are split lace and split rod closing styles . All grips feature single
offset eye for easy attachment to a pulling line .
Application
Slack Grips are widely used in pulling slack for final placement of under ground cable after it has been pulled
in . They are also used for removing cable . Standard mesh lengths are generally used in restricted space for
short pulls . Longer lengths are used for higher pulling loads where space is not restricted .
Benefits
Technical Information
• Easy attachment to pulling lines.
• Reusable rawhide lace for lace closure.
• Galvanized steel for strength.
Note: 1. Replacement rawhide lace. Catalog number 20920002.
2. See page T-44 for lace and rod closing instructions.
T-22
www.hubbell-wiring.com
Dimensions in Inches (cm)
Technical Information
Pulling Grips
Commercial Construction/Light Duty Grips
Light Duty Pulling Grips
Light Duty Pulling Grips are made of galvanized steel in a single weave construction . They feature a flexible
eye for easy attachment to a pulling line .
Application
Light Duty Grips are used in general underground electrical construction where pulling tensions are low .
They are easy tools to use in wiring industrial plants and commercial buildings .
Benefits
Kellems® Wire Management Products
Kellems® Wire Management Products
• Perfect tools for light pulling jobs.
• Installs easily on cable.
• Strong, galvanized steel construction.
Junior Duty Pulling Grips
Junior Pulling Grips feature a strong galvanized steel, single weave mesh . A flexible eye easily attaches to a
pulling line, snake or fish tape .
Application
Designed to pull building wire, Junior grips are safe tools to use in pulling wire at low tension through conduit
during electrical construction .
Benefits
•
•
•
•
Installs easily over building wire.
Strong secure grip.
Reusable.
Pulls single cable or cable bundles.
Junior Grip Kit
Junior Grip Kit contains 6 grips, one of each size . Catalog number 033051114 .
Note: See page T-27 for building wire selection chart.
Technical Information
Dimensions in Inches (cm)
www.hubbell-wiring.com
T-23
Kellems® Wire Management Products
Kellems® Wire Management Products
Technical Information
Splicing Grips
Splicing Grips
Wire Rope Splicing
Kellems Wire Rope Grips are made of high strength galvanized steel strand in a construction of triple, double
and single weave for superior gripping ability . They are available with or without a rotating barrel which will
help eliminate twist in the old rope from being transferred to the new rope .
Application
Wire Rope Grips are used for changing wire rope on oil derricks, large cranes, overhead cranes and drag
lines . It provides a quick, safe, inexpensive temporary splice . By installing the used wire rope in one end and
the new rope in the other, the new wire rope can be pulled in as the old one is pulled out .
Benefits
• High strength for secure pulling.
• Easy installation.
• Flexible to pass through sheaves and blocks.
Note: 1. During installation each end of the grip should be banded and taped down securely over the rope to insure smooth passage through sheaves and
to guard against accidental release. See page T-15 for end bands.
2. The rotating barrel is not a swivel and will not turn while under tension. It can turn to relieve pulling torque when tension is relaxed.
Cable Splicing
Splicing Grips are made of galvanized steel in double or single weave mesh construction . They are available
in various lengths and sizes to suit most applications .
Application
Splicing Grips are used as a temporary splice for rope, cable or wire rope . They can also be used as cable
reinforcement, and can act as a shield to protect cables and hoses from abrasion .
Benefits
• Easily installed or removed.
• Galvanized steel construction for strength.
• Flexible to follow cable path.
Technical Information
Note: 1. During installation, each end of the splicing grip should be banded and taped down securely to the cable to insure smooth passage with
the cable and guard against accidental release.
2. See page T-15 for end bands.
T-24
www.hubbell-wiring.com
Dimensions in Inches (cm)
Technical Information
Punch-Lok® Bands and Swivels
Accessories
Punch-Lok® Bands
Punch-Lok Bands are applied over the tail of a grip to prevent the mesh from being tripped or pulled loose .
Also, they assure full gripping action by locking the mesh of the tail in tight contact with the cable or rope .
When the tail of a grip is the leading end, the bands are particularly important to prevent accidental release
caused by tripping on obstructions . A conductor-to-conductor (double-socking) pulling operation is a good
example: where two grips connect two conductors to form a temporary splice . Bands should be applied to
the ends of the grips as illustrated on page T-15 . It is also common practice to tape over the banded
tail area to assure smooth passage through the sheaves .
The conductor should be installed in the grip up to the elbows of the aluminum shoulders in order to assure
full and complete gripping action . The banding procedure is then followed as illustrated on page T-15 .
Kellems® Wire Management Products
Kellems® Wire Management Products
Note: In all cases two Punch-Lok Bands should be double wrapped approximately 1" to 2" (2.54cm to 5.08cm) from the grip’s tail.
Banding is required to ensure maximum reliability and guard against accidental release.
Swivels
Swivels are essential to the efficiency and safety of any high tension application . They are particularly
important where continuous pulls develop higher and higher torque levels . Torque is intensified by the pullresistance of the cable itself and the resistance of the high tension controlling equipment regulating line sag .
Ball bearing swivels release torque and prevent it from reaching dangerous levels that can damage the cable
and obstruct the lines as it passes through sheaves, wheels or blocks .
Technical Information
Punch-Lok ® is a registered trademark of Punch-Lok Inc.
Dimensions in Inches (cm)
www.hubbell-wiring.com
T-25
Kellems® Wire Management Products
Kellems® Wire Management Products
Technical Information
Pulling Grips
Multiple Cable Selection Charts for Cables and Wires of Unequal Diameters
How to choose the correct grip size:
1 . Find the Grip Circumference Range by measuring the circumference
of the bundle of different diameter cables to be gripped (see illustration) .
2 . Divide the bundle circumference by 3 .14 to determine the diameter .
3 . Choose a grip offering a range of cable diameters the same as the
cable diameter .
For Pulling Grips*
CAUTION: When a grip is used on multiple cables, the tail end of the grip should be banded after positioning on the cables .
For Cables of Equal Diameters
Under “Number of Cables in One Grip”, find the diameter of your single cable in vertical column . Read the grip diameter range to the right .
If your diameter is the maximum of the range shown, go to the next larger size for Split Grips, stay with the same size for Closed Grips .
Example:
3 cables, each with .89" (2 .26cm) diameter, for a Closed Grip select the 1 .50"-1 .74" (3 .81cm-4 .42cm) range,
for a Split Grip select the 1 .75"-1 .99" (4 .44cm-5 .05cm) range .
Technical Information
Number of Cables in One Grip
2
3
4
5
6 and 7
8
9
Grip Dia.Range
Inches (cm)
.30- .38
( .76- .97)
.38- .44
( .97-1 .12)
.44- .59
(1 .12-1 .50)
.59- .75
(1 .50-1 .90)
.75- .90
(1 .90-2 .29)
.90-1 .07
(2 .29-2 .72)
1 .07-1 .22
(2 .72-3 .10)
1 .22-1 .53
(3 .10-3 .89)
1 .53-1 .83
(3 .89-4 .65)
1 .83-2 .14
(4 .65-5 .44)
2 .14-2 .44
(5 .44-6 .20)
2 .44-2 .75
(6 .20-6 .98)
2 .75-3 .06
(6 .98-7 .77)
.25- .31
( .63- .79)
.31- .36
( .79- .91)
.36- .49
( .91-1 .24)
.49- .63
(1 .24-1 .60)
.63- .76
(1 .60-1 .93)
.76- .89
(1 .93-2 .26)
.89-1 .02
(2 .26-2 .59)
1 .02-1 .28
(2 .59-3 .25)
1 .28-1 .53
(3 .25-3 .89)
1 .53-1 .79
(3 .89-4 .55)
1 .79-2 .05
(4 .55-5 .21)
2 .05-2 .30
(5 .21-5 .84)
2 .30-2 .56
(5 .84-6 .50)
.22- .27
( .56- .69)
.27- .31
( .69- .79)
.31- .42
( .79-1 .07)
.42- .54
(1 .07-1 .37)
.54- .65
(1 .37-1 .65)
.65- .77
(1 .65-1 .96)
.77- .88
(1 .96-2 .24)
.88-1 .10
(2 .24-2 .79)
1 .10-1 .32
(2 .79-3 .35)
1 .32-1 .54
(3 .35-3 .91)
1 .54-1 .76
(3 .91-4 .47)
1 .76-1 .98
(4 .47-5 .03)
1 .98-2 .20
(5 .03-5 .59)
.19- .24
( .48- .60)
.24- .29
( .61- .74)
.29- .38
( .74- .97)
.38- .48
( .97-1 .22)
.48- .58
(1 .22-1 .47)
.58- .67
(1 .47-1 .70)
.67- .77
(1 .70-1 .96)
.77- .96
(1 .96-2 .44)
.96-1 .16
(2 .44-2 .95)
1 .16-1 .35
(2 .95-3 .43)
1 .35-1 .54
(3 .43-3 .91)
1 .54-1 .74
(3 .91-4 .42)
1 .74-1 .93
(4 .42-4 .90)
.17- .22
( .43- .56)
.22- .26
( .56- .66)
.26- .34
( .66- .86)
.34- .43
( .86-1 .09)
.43- .52
(1 .09-1 .32)
.52- .60
(1 .32-1 .52)
.60- .69
(1 .52-1 .75)
.69- .86
(1 .75-2 .18)
.86-1 .03
(2 .18-2 .62)
1 .03-1 .20
(2 .62-3 .05)
1 .20-1 .37
(3 .05-3 .48)
1 .37-1 .55
(3 .48-3 .94)
1 .55-1 .72
(3 .94-4 .37)
.15- .19
( .38- .48)
.19- .23
( .48- .58)
.23- .31
( .58- .79)
.31- .39
( .79- .99)
.39- .46
( .99-1 .17)
.46- .54
(1 .17-1 .37)
.54- .62
(1 .37-1 .57)
.62- .77
(1 .57-1 .96)
.77- .93
(1 .96-2 .36)
.93-1 .08
(2 .36-2 .74)
1 .08-1 .24
(2 .74-3 .15)
1 .24-1 .39
(3 .15-3 .53)
1 .39-1 .55
(3 .53-3 .94)
.14- .18
( .36- .46)
.18- .21
( .46- .53)
.21- .28
( .53- .71)
.28- .35
( .71- .89)
.35- .42
( .89-1 .07)
.42- .49
(1 .07-1 .24)
.49- .56
(1 .24-1 .42)
.56- .71
(1 .42-1 .80)
.71- .85
(1 .80-2 .16)
.85- .99
(2 .16-2 .51)
.99-1 .13
(2 .51-2 .87)
1 .13-1 .27
(2 .87-3 .23)
1 .27-1 .41
(3 .23-3 .58)
.50- .61
(1 .27-1 .55)
.62- .74
(1 .57-1 .88)
.75- .99
(1 .90-2 .51)
1 .00-1 .24
(2 .54-3 .15)
1 .25-1 .49
(3 .17-3 .78)
1 .50-1 .74
(3 .81-4 .42)
1 .75-1 .99
(4 .44-5 .05)
2 .00-2 .49
(5 .08-6 .32)
2 .50-2 .99
(6 .35-7 .59)
3 .00-3 .49
(7 .62-8 .86)
3 .50-3 .99
(8 .89-10 .13)
4 .00-4 .49
(10 .16-11 .40)
4 .50-4 .99
(11 .43-12 .67)
Note: * This chart is not to be used for Conduit Riser Grips. Refer to the chart for Conduit Riser multiple cable section. It is always recommended that, when
multiple cables are installed in a pulling grip, the tail end be banded and tightly taped after installation on the cable bundle. See page T-15 for end bands.
T-26
www.hubbell-wiring.com
Dimensions in Inches (cm)
Technical Information
Junior Pulling Grips
Junior Pulling Grip Selection Chart
These charts are a general guide to assist in the selection of the correct Junior Pulling Grip for pulling various
groupings of building wire . It is not intended to be restrictive inasmuch as the use of “dummy" wires (short
pieces of wire used to fill out the Grip) or the tight taping of the wires into a compact bundle may increase
or decrease the number of wires per Grip .
T.H.W.N., T.H.H.N. and X.H.H.W. Building Wire
#14
#12
#10
#8
#6
#4
#3
#2
#1
#1/0
19 Strand 19 Strand 19 Strand 19 Strand 19 Strand 19 Strand 19 Strand 19 Strand 37 Strand 37 Strand
Cable
Diameter
Range
Desc. In. (cm)
Approx.
Breaking
Strength
Lbs. (N) Approximate Number Of Wires In One Grip
J 25 .25- .36
( .63- .91)
J 37 .37- .49
( .94-1 .24)
J 50 .50- .61
(1 .27-1 .55)
J 62 .62- .74
(1 .57-1 .88)
J 75 .75- .99
(1 .90-2 .51)
J 100 1 .00-1 .24
(2 .54-3 .15)
450
(2,002)
900
(4,003)
1,300
(5,782)
1,950
(8,674)
2,800
(12,454)
3,900
(17,347)
Catalog
Number
4-8
3-6
2-3
2
1
1
1
—
—
—
03305001
9-16
6-11
4-6
3
2
—
—
1
1
1
03305002
16-25
11-17
7-10
4-5
3-4
2
2
—
—
—
03305003
26-37
18-25
11-14
6-8
5-6
3
3
2
2
—
03305004
37-66
26-47
15-27
9-16
6-11
4-7
4-5
3-4
3
2-3
03305005
66-104
47-74
28-43
16-24
11-17
8-10
6-8
5-7
4-5
4
03305006
#6
7 Strand
#4
7 Strand
#2
7 Strand
#1
#1/0
19 Strand 19 Strand
Kellems® Wire Management Products
Kellems® Wire Management Products
R.H.H., R.H., R.W. and R.H.W. Building Wire
#14
7 Strand
#12
7 Strand
#10
7 Strand
#8
7 Strand
Cable
Diameter
Range
Desc. In. (cm)
Approx.
Breaking
Strength
Lbs. (N) Approximate Number Of Wires In One Grip
J 25 .25- .36
( .63- .91)
J 37 .37- .49
( .94-1 .24)
J 50 .50- .61
(1 .27-1 .55)
J 62 .62- .74
(1 .57-1 .88)
J 75 .75- .99
(1 .90-2 .51)
J 100 1 .00-1 .24
(2 .54-3 .15)
450
(2,002)
900
(4,003)
1,300
(5,782)
1,950
(8,674)
2,800
(12,454)
3,900
(17,347)
Catalog
Number
2
2
1
1
—
—
—
—
—
03305001
3
2-3
2
—
1
1
1
—
—
03305002
4-5
4-5
3-4
2
—
—
—
1
—
03305003
6-8
6-7
4-5
3
2
2
—
—
1
03305004
9-16
8-14
6-10
4-6
3-4
3-4
2-3
2
—
03305005
16-24
15-22
11-16
7-10
5-7
4-6
4
3
2-3
03305006
#14
7 Strand
#12
7 Strand
#10
7 Strand
#8
7 Strand
#6
7 Strand
#4
7 Strand
#2
7 Strand
#1
7 Strand
#1/0
19 Strand
T.H.W. Building Wire
Approx.
Breaking
Strength
Lbs. (N) Approximate Number Of Wires In One Grip
J 25 .25- .36
( .63- .91)
J 37 .37- .49
( .94-1 .24)
J 50 .50- .61
(1 .27-1 .55)
J 62 .62- .74
(1 .57-1 .88)
J 75 .75- .99
(1 .90-2 .51)
J 100 1 .00-1 .24
(2 .54-3 .15)
450
(2,002)
900
(4,003)
1,300
(5,782)
1,950
(8,674)
2,800
(12,454)
3,900
(17,347)
Dimensions in Inches (cm)
Catalog
Number
2-4
2-3
2
1
1
1
—
—
—
03305001
5-7
4-5
3-4
2
—
—
1
—
—
03305002
8-11
6-8
5-7
3-4
2
2
—
1
1
03305003
12-16
9-12
8-10
5-6
3-4
3
2
—
—
03305004
17-30
13-24
11-19
7-10
5-7
4-5
3-4
2
2
03305005
31-48
25-37
20-30
11-17
8-11
6-8
5-6
3-4
3
03305006
www.hubbell-wiring.com
T-27
Technical Information
Cable
Diameter
Range
Desc. In. (cm)
Support Grips - Heavy Duty, Standard Duty, Light Duty
Support Grips - Heavy Duty, Standard Duty, Light Duty
Kellems® Wire Management Products
Kellems® Wire Management Products
T-28
www.hubbell-wiring.com
Kellems® Wire Management Products
Kellems® Wire Management Products
Support Grips - Heavy Duty, Standard Duty, Light Duty
Tin-Coated Bronze/Stainless Steel
Solid eye assemblies provide eye reinforcement at support hardware
Four eye styles available: single (shown), double, universal, and offset
Identification tag shows: catalog number, diameter range, agency
approval, and bar code
Support Grips - Heavy Duty, Standard Duty, Light Duty
The strand equalizer positions wires for equal loading throughout the
entire grip length
The positive action mesh grip is designed for light duty up to heavy duty .
Closed grips fit over the cable end, split grips wrap around the cable
mid-span . The standard material is nonmagnetic, tin-coated bronze .
Selected items are available in stainless steel . For exceptional immunity
to rust and corrosion with superior strength and flexibility for heavy duty
support application in harsh environments; contact the factory
The endless weave provides easy installation onto cable and can be
easily repositioned
Dimensions in Inches (cm)
www.hubbell-wiring.com
T-29
Kellems® Wire Management Products
Kellems® Wire Management Products
Standard Duty Support Grips
Single Eye, Single Weave, Tin-Coated Bronze
WARNING!
It is important that you read
all breaking strength, safety
and technical data relating
to this product on pages
T-42 through T-46 .
Single Eye, Closed Mesh*
For permanent support when cable end is available to be installed through grip .
Cable Diameter
Range Inches (cm)
Approx. Breaking
Strength Lbs. (N)
E
Inches (cm)
M
Inches (cm)
Catalog
Number
.50"- .62" (1 .27-1 .57)
.63"- .74" (1 .60-1 .88)
.75"- .99" (1 .90-2 .51)
1 .00"-1 .24" (2 .54-3 .15)
1 .25"-1 .49" (3 .17-3 .78)
1 .50"-1 .74" (3 .81-4 .42)
1 .75"-1 .99" (4 .44-5 .05)
2 .00"-2 .49" (5 .08-6 .32)
2 .50"-2 .99" (6 .35-7 .59)
3 .00"-3 .49" (7 .62-8 .86)
3 .50"-3 .99" (8 .89-10 .13)
530 (2,357)
790 (3,514)
1,020 (4,537)
1,610 (7,161)
1,610 (7,161)
1,610 (7,161)
2,150 (9,563)
3,260 (14,500)
3,260 (14,500)
4,900 (21,795)
4,900 (21,795)
7" (17 .78)
8" (20 .32)
8" (20 .32)
9" (22 .86)
10" (25 .40)
12" (30 .48)
14" (35 .56)
16" (40 .64)
18" (45 .72)
21" (53 .34)
24" (60 .96)
10" (25 .40)
10" (25 .40)
13" (33 .02)
14" (35 .56)
15" (38 .10)
17" (43 .18)
19" (48 .26)
21" (53 .34)
23" (58 .42)
25" (63 .50)
27" (68 .58)
02201013
02201014
02201015
02201017
02201018
02201019
02201020
02201021
02201022
02201023
02201024
Single Eye, Split Mesh, Lace Closing*
For permanent support when cable end is not available .
Single Eye, Closed Mesh
Cable Diameter
Range Inches (cm)
Approx. Breaking
Strength Lbs. (N)
E
Inches (cm)
M
Inches (cm)
Catalog
Number
.50"- .62" (1 .27-1 .57)
.63"- .74" (1 .60-1 .88)
.75"- .99" (1 .90-2 .51)
1 .00"-1 .24" (2 .54-3 .15)
1 .25"-1 .49" (3 .17-3 .78)
1 .50"-1 .74" (3 .81-4 .42)
1 .75"-1 .99" (4 .44-5 .05)
2 .00"-2 .49" (5 .08-6 .32)
2 .50"-2 .99" (6 .35-7 .59)
3 .00"-3 .49" (7 .62-8 .86)
3 .50"-3 .99" (8 .89-10 .13)
530 (2,357)
790 (3,514)
1,020 (4,537)
1,610 (7,161)
1,610 (7,161)
1,610 (7,161)
2,150 (9,563)
3,260 (14,500)
3,260 (14,500)
4,900 (21,795)
4,900 (21,795)
7" (17 .78)
8" (20 .32)
8" (20 .32)
9" (22 .86)
10" (25 .40)
12" (30 .48)
14" (35 .56)
16" (40 .64)
18" (45 .72)
21" (53 .34)
24" (60 .96)
10" (25 .40)
10" (25 .40)
13" (33 .02)
14" (35 .56)
15" (38 .10)
17" (43 .18)
19" (48 .26)
21" (53 .34)
23" (58 .42)
25" (63 .50)
27" (68 .58)
02202013
02202014
02202015
02202017
02202018
02202019
02202020
02202021
02202022
02202023
02202024
Single Eye, Split Mesh, Rod Closing*
Standard Duty Support Grips
Single Eye, Split Mesh, Lace Closing
Single Eye, Split Mesh, Rod Closing
T-30
For support when cable end is not available .
Cable Diameter
Range Inches (cm)
Approx. Breaking
Strength Lbs. (N)
E
Inches (cm)
M
Inches (cm)
Catalog
Number
.50"- .62" (1 .27-1 .57)
.63"- .74" (1 .60-1 .88)
.75"- .99" (1 .90-2 .51)
1 .00"-1 .24" (2 .54-3 .15)
1 .25"-1 .49" (3 .17-3 .78)
1 .50"-1 .74" (3 .81-4 .42)
1 .75"-1 .99" (4 .44-5 .05)
2 .00"-2 .49" (5 .08-6 .32)
2 .50"-2 .99" (6 .35-7 .59)
3 .00"-3 .49" (7 .62-8 .86)
3 .50"-3 .99" (8 .89-10 .13)
790 (3,514)
790 (3,514)
1,020 (4,537)
1,610 (7,161)
1,610 (7,161)
1,610 (7,161)
2,150 (9,563)
3,260 (14,500)
3,260 (14,500)
5,750 (25,576)
5,750 (25,576)
7" (17 .78)
8" (20 .32)
8" (20 .32)
9" (22 .86)
10" (25 .40)
12" (30 .48)
14" (35 .56)
16" (40 .64)
18" (45 .72)
21" (53 .34)
24" (60 .96)
8 .5" (21 .59)
8 .5" (21 .59)
10 .5" (26 .67)
12 .5" (31 .75)
14 .5" (36 .83)
15 .5" (39 .37)
16 .5" (41 .91)
19 .5" (49 .53)
21 .5" (54 .61)
23 .5" (59 .69)
25 .5" (64 .77)
02203013
02203014
02203015
02203017
02203018
02203019
02203020
02203021
02203022
02203023
02203024
Note: E-Eye length.
M-Mesh length at nominal diameter.
* Change catalog number from 022 to 024 for stainless steel. Consult factory for availability.
www.hubbell-wiring.com
Dimensions in Inches (cm)
Standard Duty Support Grips
Double Eye, Single Weave, Tin-Coated Bronze
Double Eye, Closed Mesh*
For permanent support when cable end is available to be installed through grip .
Cable Diameter
Range Inches (cm)
Approx. Breaking
Strength Lbs. (N)
E
Inches (cm)
M
Inches (cm)
Catalog
Number
.50"- .62" (1 .27-1 .57)
.63"- .74" (1 .60-1 .88)
.75"- .99" (1 .90-2 .51)
1 .00"-1 .24" (2 .54-3 .15)
1 .25"-1 .49" (3 .17-3 .78)
1 .50"-1 .74" (3 .81-4 .42)
1 .75"-1 .99" (4 .44-5 .05)
2 .00"-2 .49" (5 .08-6 .32)
2 .50"-2 .99" (6 .35-7 .59)
3 .00"-3 .49" (7 .62-8 .86)
3 .50"-3 .99" (8 .89-10 .13)
530 (2,357)
790 (3,514)
1,020 (4,537)
1,610 (7,161)
1,610 (7,161)
1,610 (7,161)
2,150 (9,563)
3,260 (14,500)
3,260 (14,500)
4,900 (21,795)
4,900 (21,795)
4" (10 .16)
4" (10 .16)
4" (10 .16)
5" (12 .70)
5" (12 .70)
5" (12 .70)
6" (15 .24)
6" (15 .24)
6" (15 .24)
8" (20 .32)
8" (20 .32)
10" (25 .40)
10" (25 .40)
13" (33 .02)
14" (35 .56)
15" (38 .10)
17" (43 .18)
19" (48 .26)
21" (53 .34)
23" (58 .42)
25" (63 .50)
27" (68 .58)
02201001
02201002
02201003
02201005
02201006
02201007
02201008
02201009
02201010
02201011
02201012
WARNING!
It is important that you read
all breaking strength, safety
and technical data relating
to this product on pages
T-42 through T-46 .
Kellems® Wire Management Products
Kellems® Wire Management Products
Double Eye, Split Mesh, Lace Closing*
For permanent support when cable end is not available .
Cable Diameter
Range Inches (cm)
Approx. Breaking
Strength Lbs. (N)
E
Inches (cm)
M
Inches (cm)
Catalog
Number
.50"- .62" (1 .27-1 .57)
.63"- .74" (1 .60-1 .88)
.75"- .99" (1 .90-2 .51)
1 .00"-1 .24" (2 .54-3 .15)
1 .25"-1 .49" (3 .17-3 .78)
1 .50"-1 .74" (3 .81-4 .42)
1 .75"-1 .99" (4 .44-5 .05)
2 .00"-2 .49" (5 .08-6 .32)
2 .50"-2 .99" (6 .35-7 .59)
3 .00"-3 .49" (7 .62-8 .86)
3 .50"-3 .99" (8 .89-10 .13)
530 (2,357)
790 (3,514)
1,020 (4,537)
1,610 (7,161)
1,610 (7,161)
1,610 (7,161)
2,150 (9,563)
3,260 (14,500)
3,260 (14,500)
4,900 (21,795)
4,900 (21,795)
4" (10 .16)
4" (10 .16)
4" (10 .16)
5" (12 .70)
5" (12 .70)
5" (12 .70)
6" (15 .24)
6" (15 .24)
6" (15 .24)
8" (20 .32)
8" (20 .32)
10" (25 .40)
10" (25 .40)
13" (33 .02)
14" (35 .56)
15" (38 .10)
17" (43 .18)
19" (48 .26)
21" (53 .34)
23" (58 .42)
25" (63 .50)
27" (68 .58)
02202001
02202002
02202003
02202005
02202006
02202007
02202008
02202009
02202010
02202011
02202012
Double Eye, Closed Mesh
Double Eye, Split Mesh, Rod Closing*
For support when cable end is not available .
Double Eye, Split Mesh, Lace Closing
Approx. Breaking
Strength Lbs. (N)
E
Inches (cm)
M
Inches (cm)
Catalog
Number
.50"- .62" (1 .27-1 .57)
.63"- .74" (1 .60-1 .88)
.75"- .99" (1 .90-2 .51)
1 .00"-1 .24" (2 .54-3 .15)
1 .25"-1 .49" (3 .17-3 .78)
1 .50"-1 .74" (3 .81-4 .42)
1 .75"-1 .99" (4 .44-5 .05)
2 .00"-2 .49" (5 .08-6 .32)
2 .50"-2 .99" (6 .35-7 .59)
3 .00"-3 .49" (7 .62-8 .86)
3 .50"-3 .99" (8 .89-10 .13)
790 (3,514)
790 (3,514)
1,020 (4,537)
1,610 (7,161)
1,610 (7,161)
1,610 (7,161)
2,150 (9,563)
3,260 (14,500)
3,260 (14,500)
5,750 (25,576)
5,750 (25,576)
4" (10 .16)
4" (10 .16)
4" (10 .16)
5" (12 .70)
5" (12 .70)
5" (12 .70)
6" (15 .24)
6" (15 .24)
6" (15 .24)
8" (20 .32)
8" (20 .32)
8.5" (21 .59)
8 .5" (21 .59)
10 .5" (26 .67)
12 .5" (31 .75)
14 .5" (36 .83)
15 .5" (39 .37)
16 .5" (41 .91)
19 .5" (49 .53)
21 .5" (54 .61)
23 .5" (59 .69)
25 .5" (64 .77)
02203001
02203002
02203003
02203005
02203006
02203007
02203008
02203009
02203010
02203011
02203012
Note: E-Eye length.
M-Mesh length at nominal diameter.
* Change catalog number from 022 to 024 for stainless steel. Consult factory for availability.
Dimensions in Inches (cm)
www.hubbell-wiring.com
Double Eye, Split Mesh, Rod Closing
T-31
Standard Duty Support Grips
Cable Diameter
Range Inches (cm)
Kellems® Wire Management Products
Kellems® Wire Management Products
Standard Duty Support Grips
Offset Eye, Single Weave, Tin-Coated Bronze
WARNING!
It is important that you read
all breaking strength, safety
and technical data relating
to this product on pages
T-42 through T-46 .
Offset Eye, Closed Mesh*
For permanent support when cable end is available to be installed through grip .
Cable Diameter
Range Inches (cm)
Approx. Breaking
Strength Lbs. (N)
E
Inches (cm)
M
Inches (cm)
Catalog
Number
.50"- .62" (1 .27-1 .57)
.63"- .74" (1 .60-1 .88)
.75"- .99" (1 .90-2 .51)
1 .00"-1 .24" (2 .54-3 .15)
1 .25"-1 .49" (3 .17-3 .78)
1 .50"-1 .74" (3 .81-4 .42)
1 .75"-1 .99" (4 .44-5 .05)
2 .00"-2 .49" (5 .08-6 .32)
2 .50"-2 .99" (6 .35-7 .59)
3 .00"-3 .49" (7 .62-8 .86)
3 .50"-3 .99" (8 .89-10 .13)
500 (2,224)
750 (3,336)
950 (4,226)
1,500 (6,672)
1,500 (6,672)
1,500 (6,672)
2,000 (8,896)
3,100 (13,789)
3,100 (13,789)
3,800 (16,902)
3,250 (14,480)
4" (10 .16)
4" (10 .16)
4" (10 .16)
5" (12 .70)
5" (12 .70)
5" (12 .70)
6" (15 .24)
9" (22 .86)
9" (22 .86)
11" (27 .94)
11" (27 .94)
10" (25 .40)
10" (25 .40)
13" (33 .02)
14" (35 .56)
15" (38 .10)
17" (43 .18)
19" (48 .26)
21" (53 .34)
23" (58 .42)
25" (63 .50)
27" (68 .58)
02201037
02201038
02201039
02201041
02201042
02201043
02201044
02201045
02201046
02201047
02201048
Offset Eye, Split Mesh, Lace Closing*
For permanent support when cable end is not available .
Offset Eye, Closed Mesh
Cable Diameter
Range Inches (cm)
Approx. Breaking
Strength Lbs. (N)
E
Inches (cm)
M
Inches (cm)
Catalog
Number
.50"- .62" (1 .27-1 .57)
.63"- .74" (1 .60-1 .88)
.75"- .99" (1 .90-2 .51)
1 .00"-1 .24" (2 .54-3 .15)
1 .25"-1 .49" (3 .17-3 .78)
1 .50"-1 .74" (3 .81-4 .42)
1 .75"-1 .99" (4 .44-5 .05)
2 .00"-2 .49" (5 .08-6 .32)
2 .50"-2 .99" (6 .35-7 .59)
3 .00"-3 .49" (7 .62-8 .86)
3 .50"-3 .99" (8 .89-10 .13)
500 (2,224)
750 (3,336)
950 (4,226)
1,500 (6,672)
1,500 (6,672)
1,500 (6,672)
1,800 (8,006)
2,150 (9,563)
2,150 (9,563)
3,250 (14,480)
3,250 (14,480)
4" (10 .16)
4" (10 .16)
4" (10 .16)
5" (12 .70)
5" (12 .70)
5" (12 .70)
6" (15 .24)
9" (22 .86)
9" (22 .86)
11" (27 .94)
11" (27 .94)
10" (25 .40)
10" (25 .40)
13" (33 .02)
14" (35 .56)
15" (38 .10)
17" (43 .18)
19" (48 .26)
21" (53 .34)
23" (58 .42)
25" (63 .50)
27" (68 .58)
02202037
02202038
02202039
02202041
02202042
02202043
02202044
02202045
02202046
02202047
02202048
Offset Eye, Split Mesh, Rod Closing*
Standard Duty Support Grips
Offset Eye, Split Mesh, Lace Closing
Offset Eye, Split Mesh, Rod Closing
T-32
For support when cable end is not available .
Cable Diameter
Range Inches (cm)
Approx. Breaking
Strength Lbs. (N)
E
Inches (cm)
M
Inches (cm)
Catalog
Number
.50"- .62" (1 .27-1 .57)
.63"- .74" (1 .60-1 .88)
.75"- .99" (1 .90-2 .51)
1 .00"-1 .24" (2 .54-3 .15)
1 .25"-1 .49" (3 .17-3 .78)
1 .50"-1 .74" (3 .81-4 .42)
1 .75"-1 .99" (4 .44-5 .05)
2 .00"-2 .49" (5 .08-6 .32)
2 .50"-2 .99" (6 .35-7 .59)
3 .00"-3 .49" (7 .62-8 .86)
3 .50"-3 .99" (8 .89-10 .13)
500 (2,224)
750 (3,336)
950 (4,226)
1,500 (6,672)
1,500 (6,672)
1,500 (6,672)
2,000 (8,896)
3,100 (13,789)
3,100 (13,789)
4,300 (19,126)
4,900 (21,795)
4" (10 .16)
4" (10 .16)
4" (10 .16)
5" (12 .70)
5" (12 .70)
5" (12 .70)
6" (15 .24)
9" (22 .86)
9" (22 .86)
11" (27 .94)
11" (27 .94)
7" (17 .78)
9" (22 .86)
10" (25 .40)
12" (30 .48)
14" (35 .56)
15" (38 .10)
16" (40 .64)
19" (48 .26)
20" (50 .80)
21" (53 .34)
21" (53 .34)
02203037
02203038
02203039
02203041
02203042
02203043
02203044
02203045
02203046
02203047
02203048
Note: E-Eye length.
M-Mesh length at nominal diameter.
* Change catalog number from 022 to 024 for stainless steel. Consult factory for availability.
www.hubbell-wiring.com
Dimensions in Inches (cm)
Standard Duty Support Grips
Universal Eye, Single Weave, Tin-Coated Bronze
Universal Eye, Closed Mesh*
For permanent support when cable end is available to be installed through grip .
Cable Diameter
Range Inches (cm)
Approx. Breaking
Strength Lbs. (N)
E
Inches (cm)
M
Inches (cm)
Catalog
Number
.50"- .62" (1 .27-1 .57)
.63"- .74" (1 .60-1 .88)
.75"- .99" (1 .90-2 .51)
1 .00"-1 .24" (2 .54-3 .15)
1 .25"-1 .49" (3 .17-3 .78)
1 .50"-1 .74" (3 .81-4 .42)
1 .75"-1 .99" (4 .44-5 .05)
2 .00"-2 .49" (5 .08-6 .32)
2 .50"-2 .99" (6 .35-7 .59)
530 (2,357)
790 (3,514)
1,020 (4,537)
1,610 (7,161)
1,610 (7,161)
1,610 (7,161)
2,150 (9,563)
3,260 (14,500)
3,260 (14,500)
18" (45 .72)
18" (45 .72)
18" (45 .72)
18" (45 .72)
18" (45 .72)
18" (45 .72)
18" (45 .72)
18" (45 .72)
18" (45 .72)
10" (25 .40)
10" (25 .40)
13" (33 .02)
14" (35 .56)
15" (38 .10)
17" (43 .18)
19" (48 .26)
21" (53 .34)
23" (58 .42)
02201051
02201052
02201053
02201050
02201054
02201055
02201056
02201057
02201058
WARNING!
It is important that you read
all breaking strength, safety
and technical data relating
to this product on pages
T-42 through T-46 .
Kellems® Wire Management Products
Kellems® Wire Management Products
Universal Eye, Split Mesh, Lace Closing
For permanent support when cable end is not available .
Cable Diameter
Range Inches (cm)
Approx. Breaking
Strength Lbs. (N)
E
Inches (cm)
M
Inches (cm)
Catalog
Number
.50"- .62" (1 .27-1 .57)
.63"- .74" (1 .60-1 .88)
.75"- .99" (1 .90-2 .51)
1 .00"-1 .24" (2 .54-3 .15)
1 .25"-1 .49" (3 .17-3 .78)
1 .50"-1 .74" (3 .81-4 .42)
1 .75"-1 .99" (4 .44-5 .05)
2 .00"-2 .49" (5 .08-6 .32)
2 .50"-2 .99" (6 .35-7 .59)
3 .50"-3 .99" (8 .89-10 .13)
530 (2,357)
790 (3,514)
1,020 (4,537)
1,610 (7,161)
1,610 (7,161)
1,610 (7,161)
2,150 (9,563)
3,260 (14,500)
3,260 (14,500)
4,900 (21,795)
18" (45 .72)
18" (45 .72)
18" (45 .72)
18" (45 .72)
18" (45 .72)
18" (45 .72)
18" (45 .72)
18" (45 .72)
18" (45 .72)
18" (45 .72)
10" (25 .40)
10" (25 .40)
13" (33 .02)
14" (35 .56)
15" (38 .10)
17" (43 .18)
19" (48 .26)
21" (53 .34)
23" (58 .42)
27" (68 .58)
02202050
02202051
02202052
02202054
02202055
02202056
02202057
02202058
02202059
02202061
Universal Eye, Closed Mesh
Universal Eye, Split Mesh, Rod Closing*
For support when cable end is not available .
Approx. Breaking
Strength Lbs. (N)
E
Inches (cm)
M
Inches (cm)
Catalog
Number
.50"- .62" (1 .27-1 .57)
.63"- .74" (1 .60-1 .88)
.75"- .99" (1 .90-2 .51)
1 .00"-1 .24" (2 .54-3 .15)
1 .25"-1 .49" (3 .17-3 .78)
1 .50"-1 .74" (3 .81-4 .42)
1 .75"-1 .99" (4 .44-5 .05)
2 .00"-2 .49" (5 .08-6 .32)
2 .50"-2 .99" (6 .35-7 .59)
3 .00"-3 .49" (7 .62-8 .86)
790 (3,514)
790 (3,514)
1,020 (4,537)
1,610 (7,161)
1,610 (7,161)
1,610 (7,161)
2,150 (9,563)
3,260 (14,500)
3,260 (14,500)
5,750 (25,576)
18" (45 .72)
18" (45 .72)
18" (45 .72)
18" (45 .72)
18" (45 .72)
18" (45 .72)
18" (45 .72)
18" (45 .72)
18" (45 .72)
18" (45 .72)
8 .5" (21 .59)
8 .5" (21 .59)
10 .5" (26 .67)
12 .5" (31 .75)
14 .5" (36 .83)
15 .5" (39 .37)
16 .5" (41 .91)
19 .5" (49 .53)
21 .5" (54 .61)
23 .5" (59 .69)
02203064
02203065
02203066
02203068
02203069
02203070
02203071
02203072
02203073
02203074
Universal Eye, Split Mesh, Lace Closing
Note: E-Eye length.
M-Mesh length at nominal diameter.
* Change catalog number from 022 to 024 for stainless steel. Consult factory for availability.
Universal Eye, Split Mesh, Rod Closing
Dimensions in Inches (cm)
www.hubbell-wiring.com
T-33
Standard Duty Support Grips
Cable Diameter
Range Inches (cm)
Kellems® Wire Management Products
Kellems® Wire Management Products
Heavy Duty Support Grips
Single Eye, Double Weave, Tin-Coated Bronze
WARNING!
It is important that you read
all breaking strength, safety
and technical data relating
to this product on pages
T-42 through T-46 .
Heavy Duty, Single Eye, Closed Mesh*
For heavy duty permanent support when cable end is available to be installed through grip .
Cable Diameter
Range Inches (cm)
Approx. Breaking
Strength Lbs. (N)
E
Inches (cm)
M
Inches (cm)
Catalog
Number
.75"- .99" (1 .90-2 .51)
1 .00"-1 .24" (2 .54-3 .15)
1 .25"-1 .49" (3 .17-3 .78)
1 .50"-1 .99" (3 .81-5 .05)
2,820 (12,543)
4,280 (19,037)
4,280 (19,037)
4,280 (19,037)
10" (25 .40)
12" (30 .48)
12" (30 .48)
12" (30 .48)
25" (63 .50)
28" (71 .12)
30" (76 .20)
34" (86 .36)
02206010
02206011
02206012
02206013
Heavy Duty, Single Eye, Closed Mesh
Single Eye, Split Mesh, Lace Closing*
For permanent support when cable end is not available to be installed through grip .
Cable Diameter
Range Inches (cm)
Approx. Breaking
Strength Lbs. (N)
E
Inches (cm)
M
Inches (cm)
Catalog
Number
.75"- .99" (1 .90-2 .51)
1 .00"-1 .24" (2 .54-3 .15)
1 .25"-1 .49" (3 .17-3 .78)
1 .50"-1 .99" (3 .81-5 .05)
2,820 (12,543)
4,280 (19,037)
4,280 (19,037)
4,280 (19,037)
10" (25 .40)
12" (30 .48)
12" (30 .48)
12" (30 .48)
25" (63 .50)
28" (71 .12)
30" (76 .20)
34" (86 .36)
02207010
02207011
02207012
02207013
Note: E-Eye length.
M-Mesh length at nominal diameter.
* Change catalog number from 022 to 024 for stainless steel. Consult factory for availability.
Heavy Duty Support Grips
Single Eye, Split Mesh, Lace Closing
T-34
www.hubbell-wiring.com
Dimensions in Inches (cm)
Heavy Duty Support Grips
Double Eye, Double Weave, Tin-Coated Bronze
WARNING!
It is important that you read
all breaking strength, safety
and technical data relating
to this product on pages
T-42 through T-46 .
Double Eye, Closed Mesh*
For permanent support when cable end is available to be installed through grip .
Cable Diameter
Range Inches (cm)
Approx. Breaking
Strength Lbs. (N)
E
Inches (cm)
M
Inches (cm)
Catalog
Number
.75"- .99"(1 .90-2 .51)
1 .00"-1 .24" (2 .54-3 .15)
1 .25"-1 .49" (3 .17-3 .78)
1 .50"-1 .99" (3 .81-5 .05)
2 .00"-2 .49" (5 .08-6 .32)
2 .50"-2 .99" (6 .35-7 .59)
3 .00"-3 .49" (7 .62-8 .86)
3 .50"-3 .99" (8 .89-10 .13)
4 .00"-4 .49" (10 .16-11 .40)
4 .50"-4 .99" (11 .43-12 .67)
2,820 (12,543)
4,280 (19,037)
4,280 (19,037)
4,280 (19,037)
8,050 (35,806)
8,050 (35,806)
10,060 (44,747)
12,070 (53,687)
12,070 (53,687)
12,070 (53,687)
10" (25 .40)
10" (25 .40)
10" (25 .40)
10" (25 .40)
12" (30 .48)
12" (30 .48)
12" (30 .48)
12" (30 .48)
12" (30 .48)
12" (30 .48)
25" (63 .50)
28" (71 .12)
30" (76 .20)
34" (86 .36)
36" (91 .44)
38" (96 .52)
40" (101 .60)
44" (111 .76)
46" (116 .84)
68" (172 .72)
02206001
02206002
02206003
02206004
02206005
02206006
02206007
02206008
02206009
02208009
Kellems® Wire Management Products
Kellems® Wire Management Products
Double Eye, Closed Mesh
Double Eye, Split Mesh, Lace Closing*
For support when cable end is not available .
Cable Diameter
Range Inches (cm)
Approx. Breaking
Strength Lbs. (N)
E
Inches (cm)
M
Inches (cm)
Catalog
Number
.75"- .99" (1 .90-2 .51)
1 .00"-1 .24" (2 .54-3 .15)
1 .25"-1 .49" (3 .17-3 .78)
1 .50"-1 .99" (3 .81-5 .05)
2 .00"-2 .49" (5 .08-6 .32)
2 .50"-2 .99" (6 .35-7 .59)
3 .00"-3 .49" (7 .62-8 .86)
3 .50"-3 .99" (8 .89-10 .13)
4 .00"-4 .49" (10 .16-11 .40)
4 .50"-4 .99" (11 .43-12 .67)
2,820 (12,543)
4,280 (19,037)
4,280 (19,037)
4,280 (19,037)
8,050 (35,806)
8,050 (35,806)
10,060 (44,747)
12,070 (53,687)
12,070 (53,687)
12,070 (53,687)
10" (25 .40)
10" (25 .40)
10" (25 .40)
10" (25 .40)
12" (30 .48)
12" (30 .48)
12" (30 .48)
12" (30 .48)
12" (30 .48)
12" (30 .48)
25" (63 .50)
28" (71 .12)
30" (76 .20)
34" (86 .36)
36" (91 .44)
38" (96 .52)
40" (101 .60)
44" (111 .76)
46" (116 .84)
68" (172 .72)
02207001
02207002
02207003
02207004
02207005
02207006
02207007
02207008
02207009
02209009
Double Eye, Split Mesh, Lace Closing
Dimensions in Inches (cm)
www.hubbell-wiring.com
Heavy Duty Support Grips
Note: E-Eye length.
M-Mesh length at nominal diameter.
* Change catalog number from 022 to 024 for stainless steel. Consult factory for availability.
T-35
Kellems® Wire Management Products
Kellems® Wire Management Products
Service Drop Grips
Single Eye, Tin-Coated Bronze
WARNING!
It is important that you read
all breaking strength, safety
and technical data relating
to this product on pages
T-42 through T-46 .
Light Duty, Single Eye, Closed Mesh, Single Weave
Light Duty, Single Eye, Closed Mesh,
Single Weave
Heavy Duty, Single Eye, Closed Mesh, Multi-Weave
Heavy Duty, Single Eye, Closed Mesh,
Multi-Weave
For permanent support when cable end is available to be installed .
Cable Diameter
Range Inches (cm)
Approx. Breaking
Strength Lbs. (N)
E
Inches (cm)
M
Inches (cm)
Catalog
Number
.23"- .31" ( .58- .79)
.29"- .37" ( .74- .94)
.35"- .44" ( .89-1 .12)
.41"- .50" (1 .04-1 .27)
.46"- .56" (1 .17-1 .42)
.52"- .62" (1 .32-1 .57)
.58"- .68" (1 .47-1 .73)
.64"- .75" (1 .63-1 .90)
.70"- .81" (1 .78-2 .06)
.75"- .87" (1 .90-2 .21)
.81"- .94" (2 .06-2 .39)
.87"-1 .00" (2 .21-2 .54)
.94"-1 .06" (2 .39-2 .69)
1 .00"-1 .18" (2 .54-3 .00)
1 .06"-1 .25" (2 .69-3 .17)
290 (1,290)
290 (1,290)
500 (2,224)
500 (2,224)
660 (2,936)
790 (3,514)
790 (3,514)
790 (3,514)
790 (3,514)
1,020 (4,537)
1,020 (4,537)
1,020 (4,537)
1,020 (4,537)
1,020 (4,537)
1,020 (4,537)
3" (7 .62)
5" (12 .70)
5 .5" (13 .97)
5 .5" (13 .97)
6" (15 .24)
7" (17 .78)
7" (17 .78)
7" (17 .78)
7" (17 .78)
8" (20 .32)
8" (20 .32)
8" (20 .32)
9" (22 .86)
9" (22 .86)
9" (22 .86)
3 .75" (9 .52)
4 .25" (10 .79)
4 .75" (12 .06)
5" (12 .70)
5 .25" (13 .33)
6 .25" (15 .87)
6¹⁄₂" (16 .51)
6 .75" (17 .14)
7 .25" (18 .41)
8" (20 .32)
8 .25" (20 .95)
8 .75" (22 .22)
9" (22 .86)
9 .5" (24 .13)
9 .5" (24 .13)
02216001
02216002
02216003
02216004
02216005
02216006
02216007
02216008
02216009
02216010
02216011
02216012
02216013
02216014
02216015
For permanent support when cable end is available to be installed .
Cable Diameter
Range Inches (cm)
Approx. Breaking
Strength Lbs. (N)
E
Inches (cm)
M
Inches (cm)
Catalog
Number
.23"- .31" ( .58- .79)
.29"- .37" ( .74- .94)
.35"- .44" ( .89-1 .12)
.41"- .50" (1 .04-1 .27)
.46"- .56" (1 .17-1 .42)
.52"- .62" (1 .32-1 .57)
.58"- .68" (1 .47-1 .73)
.64"- .75" (1 .63-1 .90)
.70"- .81" (1 .78-2 .06)
.75"- .87" (1 .90-2 .21)
.81"- .94" (2 .06-2 .39)
.87"-1 .00" (2 .21-2 .54)
.94"-1 .06" (2 .39-2 .69)
1 .00"-1 .18" (2 .54-3 .00)
1 .06"-1 .25" (2 .69-3 .17)
500 (2,224)
500 (2,224)
870 (3,870)
870 (3,870)
1,050 (4,670)
1,050 (4,670)
1,050 (4,670)
1,390 (6,183)
1,390 (6,183)
1,390 (6,183)
1,390 (6,183)
1,790 (7,962)
1,790 (7,962)
1,790 (7,962)
1,790 (7,962)
5" (12 .70)
5" (12 .70)
6" (15 .24)
6" (15 .24)
6" (15 .24)
7" (17 .78)
7" (17 .78)
7" (17 .78)
8" (20 .32)
8" (20 .32)
8" (20 .32)
8" (20 .32)
9" (22 .86)
9" (22 .86)
9" (22 .86)
4 .5" (11 .43)
5 .5" (13 .97)
6 .5" (16 .51)
7 .5" (19 .05)
8" (20 .32)
8 .5" (21 .59)
9 .5" (24 .13)
9 .5" (24 .13)
10 .5" (26 .67)
10 .5" (26 .67)
10 .5" (26 .67)
11 .5" (29 .21)
12 .5" (31 .75)
13 .5" (34 .29)
14 .5" (36 .83)
02217001
02217002
02217003
02217004
02217005
02217006
02217007
02217008
02217009
02217010
02217011
02217012
02217013
02217014
02217015
Note: E-Eye length.
M-Mesh length at nominal diameter.
Service Drop Grips
.250''
(.64)
.3125''
(.80) Dia.
2.000''
(5.08)
Screw Hook
Catalog Number 20303001
Yield Strength 900 lbs (4003 N)
T-36
www.hubbell-wiring.com
4.875''
(12.38)
Dimensions in Inches (cm)
Service Drop Grips
Universal Eye, Tin-Coated Bronze
Light Duty, Universal Eye, Closed Mesh, Single Weave
For permanent support when cable end is available to be installed .
Cable Diameter
Range Inches (cm)
Approx. Breaking
Strength Lbs. (N)
E
Inches (cm)
M
Inches (cm)
Catalog
Number
.23"- .31" ( .58- .79)
.29"- .37" ( .74- .94)
.35"- .44" ( .89-1 .12)
.41"- .50" (1 .04-1 .27)
.46"- .56" (1 .17-1 .42)
.52"- .62" (1 .32-1 .57)
.58"- .68" (1 .47-1 .73)
.64"- .75" (1 .63-1 .90)
.70"- .81" (1 .78-2 .06)
.75"- .87" (1 .90-2 .21)
.81"- .94" (2 .06-2 .39)
.87"-1 .00" (2 .21-2 .54)
.94"-1 .06" (2 .39-2 .69)
1 .00"-1 .18" (2 .54-3 .00)
1 .06"-1 .25" (2 .69-3 .17)
290 (1,290)
290 (1,290)
500 (2,224)
500 (2,224)
660 (2,936)
790 (3,514)
790 (3,514)
790 (3,514)
790 (3,514)
1,020 (4,537)
1,020 (4,537)
1,020 (4,537)
1,020 (4,537)
1,020 (4,537)
1,020 (4,537)
9" (22 .86)
10" (25 .40)
10" (25 .40)
11" (27 .94)
12" (30 .48)
13" (33 .02)
13" (33 .02)
13" (33 .02)
13" (33 .02)
14" (35 .56)
14" (35 .56)
14" (35 .56)
15" (38 .10)
15" (38 .10)
15" (38 .10)
3 .75" (9 .52)
4 .25" (10 .79)
4 .75" (12 .06)
5" (12 .70)
5 .25" (13 .33)
6 .25" (15 .87)
6 .5" (16 .51)
6 .75" (17 .14)
7 .25" (18 .41)
8" (20 .32)
8 .25" (20 .95)
8 .75" (22 .22)
9" (22 .86)
9 .5" (24 .13)
9 .5" (24 .13)
02216016
02216017
02216018
02216019
02216020
02216021
02216022
02216023
02216024
02216025
02216026
02216027
02216028
02216029
02216030
Heavy Duty, Universal Eye, Closed Mesh, Multi-Weave
WARNING!
It is important that you read
all breaking strength, safety
and technical data relating
to this product on pages
T-42 through T-46 .
Kellems® Wire Management Products
Kellems® Wire Management Products
Light Duty, Universal Eye,
Closed Mesh, Single Weave
For permanent support when cable end is available to be installed .
Cable Diameter
Range Inches (cm)
Approx. Breaking
Strength Lbs. (N)
E
Inches (cm)
M
Inches (cm)
Catalog
Number
.23"- .31" ( .58- .79)
.28"- .37" ( .74- .94)
.35"- .44" ( .89-1 .12)
.41"- .50" (1 .04-1 .27)
.46"- .56" (1 .17-1 .42)
.52"- .62" (1 .32-1 .57)
.58"- .68" (1 .47-1 .73)
.64"- .75" (1 .63-1 .90)
.70"- .81" (1 .78-2 .06)
.75"- .87" (1 .90-2 .21)
.81"- .94" (2 .06-2 .39)
.87"-1 .00" (2 .21-2 .54)
.94"-1 .06" (2 .39-2 .69)
1 .00"-1 .18" (2 .54-3 .00)
1 .06"-1 .25" (2 .69-3 .17)
500 (2,224)
500 (2,224)
870 (3,870)
870 (3,870)
1,050 (4,670)
1,050 (4,670)
1,050 (4,670)
1,390 (6,183)
1,390 (6,183)
1,390 (6,183)
1,390 (6,183)
1,790 (7,962)
1,790 (7,962)
1,790 (7,962)
1,790 (7,962)
11" (27 .94)
11" (27 .94)
12" (30 .48)
12" (30 .48)
12" (30 .48)
13" (33 .02)
13" (33 .02)
13" (33 .02)
14" (35 .56)
14" (35 .56)
14" (35 .56)
14" (35 .56)
15" (38 .10)
15" (38 .10)
15" (38 .10)
4 .5" (11 .43)
5 .5" (13 .97)
6 .5" (16 .51)
7 .5" (19 .05)
8" (20 .32)
8 .5" (21 .59)
9 .5" (24 .13)
9 .5" (24 .13)
10 .5" (26 .67)
10 .5" (26 .67)
10 .5" (26 .67)
11 .5" (29 .21)
12 .5" (31 .75)
13 .5" (34 .29)
14 .5" (36 .83)
02217016
02217017
02217018
02217019
02217020
02217021
02217022
02217023
02217024
02217025
02217026
02217027
02217028
02217029
02217030
Heavy Duty, Universal Eye,
Closed Mesh, Multi-Weave
Note: E-Eye length.
M-Mesh length at nominal diameter.
Service Drop Grips
Dimensions in Inches (cm)
www.hubbell-wiring.com
T-37
Kellems® Wire Management Products
Kellems® Wire Management Products
Bus Drop Support Grips
Single Eye, Universal Eye, Galvanized Steel
WARNING!
It is important that you read
all breaking strength, safety
and technical data relating
to this product on pages
T-42 through T-46 .
Safety Spring
Maximum
Deflection
Inches/Lbs
(cm/N)
Approx.
Breaking
Strength
Lbs. (N)
Length*
Inches
(cm)
Diameter
Inches
(cm)
Model
Lbs. (N)
Catalog
Number
2¾" at 40 lbs.
(6.98 cm at 178 N)
3¹⁄⁄" at 80 lbs.
(7.94 cm at 356 N)
500
(2,224)
850
(3,781)
8.25"
(20.95)
8.25"
(20.95)
.75"
(1.90)
1"
(2.54)
40 lb. spring
(178)
80 lb. spring
(356)
20302001
20302002
Note: Springs can be used with single eye grips by disassembling drawbar from coil, placing through eye
and replacing drawbar.
* No load.
Safety Spring
Single Eye, Wide Range
Cable Diameter
Range Inches (cm)
Approx. Breaking
Strength Lbs. (N)
E
Inches (cm)
M
Inches (cm)
Catalog
Number
.24"-.32" (.61-.81)
.32"-.43" (.81-1.09)
.43"-.56" (1.09-1.42)
.56"-.73" (1.42-1.85)
.73"-.85" (1.85-2.16)
.85"-1.00" (2.16-2.54)
1.00"-1.25" (2.54-3.17)
350 (1,557)
450 (2,002)
550 (2,446)
1,000 (4,448)
1,400 (6,227)
1,400 (6,227)
1,500 (6,672)
3" (7.62)
4" (10.16)
6" (15.24)
7" (17.78)
7" (17.78)
8" (20.32)
9" (22.86)
3.5" (8.89)
4" (10.16)
4.75" (12.06)
6" (15.24)
6.75" (17.14)
8" (20.32)
9.5" (24.13)
073041276**
073041277
073041278
073041279
073041280
073041281
073041282
Universal Eye, Wide Range
Single Eye, Wide Range
Cable Diameter
Range Inches (cm)
Approx. Breaking
Strength Lbs. (N)
E
Inches (cm)
M
Inches (cm)
Catalog
Number
.32"-.43" (.81-1.09)
.43"-.56" (1.09-1.42)
.56"-.73" (1.42-1.85)
.73"-.85" (1.85-2.16)
.85"-1.00" (2.16-2.54)
1.00"-1.25" (2.54-3.17)
450 (2,002)
550 (2,446)
1,000 (4,448)
1,400 (6,227)
1,400 (6,227)
1,500 (6,672)
10" (25.40)
12" (30.48)
13" (33.02)
13" (33.02)
14" (35.56)
15" (38.10)
4" (10.16)
4.75" (12.06)
6" (15.24)
6.75" (17.14)
8" (20.32)
9.5" (24.13)
073041284
073041285
073041286
073041287
073041288
073041289
Note: E-Eye length.
M-Mesh length at nominal diameter.
** Item indicated is not UL listed.
Bus Drop Grips and Safety Springs
Bus Drop Support Grips
Universal Eye, Wide Range
Kellems Bus Drop Grips are offered with either a single eye or universal
bale attachment . The mesh is single weave galvanized steel with the patented
wide range construction . They are suitable for indoor use only . Consult Technical
Service for Stainless Steel Grips .
Application
Safety Spring
Bus Drop Grips provide a safe, easy and economical method to support flexible cord or
bus drop cable at bus duct and other industrial areas .
Benefits
Strain
Relief
Grip
• Easily installed.
• Absorb tension, vibration and pull with no cable damage.
• Patented mesh construction.
Bus
Drop
Grips
Strain
Relief
Grip
Safety Spring
Springs can be used with single eye grips by disassembling drawbar from coil, placing
through eye and replacing drawbar .
Motor Box
T-38
www.hubbell-wiring.com
Dimensions in Inches (cm)
Kellems® Wire Management Products
Wire Management Products
Conduit Riser Grips
Ring Type, Single Weave, Tin-Coated Bronze
WARNING!
It is important that you read all breaking strength, safety and technical
data relating to this product on pages T-47 and T-48 .
Single Weave, Closed Mesh
Kellems® Conduit Riser Support Grips are available in closed mesh and
in split mesh with lace or rod closures, to cover all applications including
single cable or multiple wire support . Refer to technical section, T-47 for
grip selection assistance for cable bundles . The standard material is tincoated bronze strand . The grip is permanently fastened to a support ring,
resulting in a one piece unit which will allow air ventilation within the
conduit . The ring will fit standard electrical rigid metal conduit and
schedule 40 rigid PVC conduit only . See page T-48 for ring dimensions .
For permanent support when cable end is available to be installed
through the grip .
Suitable For Standard Electrical Rigid Metal Conduit and Schedule 40 Rigid PVC Conduit Only
Cable Sizes .50"- .62" .63"-.74"
.75"- .99"
Inches (cm) (1.27-1.57) (1.60-1-88) (1.90-2.51)
Model
R050
Length
Inches (cm) 8" (20.32)
Conduit
Sizes
Inches
1.00"- 1.24" 1.25"- 1.49" 1.50"-1.74"
(2.54-3.15) (3.17-3.78) (3.81-4.42)
1.75"-1.99"
(4.44-5.05)
2.00"- 2.49"
(5.08-6.32)
2.50" -2.99"
(6.35-7.59)
3.00"- 3.49"
(7.62-8.86)
3.50"- 3.99"
(8.89-10.13)
R062
R075
R100
R125
R150
R175
R200
R250
R300
R350
9" (22.86)
11" (27.94)
12" (30.48)
12" (30.48)
14" (35.56)
15" (38.10)
17" (43.18)
18" (45.72)
20" (50.80)
21" (53.34)
Catalog Number
Approx. Breaking Strength Lbs. (N)
02211106 —
530 (2,357)
—
—
—
—
—
—
—
—
—
1
02211100 02211101 —
490 (2,179) 790 (3,514)
—
—
—
—
—
—
—
—
1¼
02211001 02211002 02211003 —
450 (2,002) 740 (3,292) 1,030 (4,581)
—
—
—
—
—
—
—
1½
—
02211006 02211007 02211009 —
690 (3,069) 970 (4,315) 1,610 (7,161)
—
—
—
—
—
—
2
—
02211107 02211010 02211012 02211013 —
640 (2,847) 920 (4,092) 1,520 (6,761) 1,610 (7,161)
—
—
—
—
—
2½
—
—
—
—
02211017 02211018 02211019 —
1,510 (6,716) 1,610 (7,161) 2,150 (9,563)
—
—
—
3
—
—
—
02211022 02211023 02211024 02211025 02211026
1,340 (5,960) 1,400 (6,227) 1,490 (6,627) 1,990 (8,851) 3,260 (14,500)
—
—
—
3½
—
—
—
—
—
—
—
02211034
—
3,260 (14,500)
—
4
—
—
—
—
—
—
02211040 02211041
1,670 (7,248) 2,680 (11,921)
02211042
02211043
—
2,890 (12,855) 4,080 (18,148)
5
—
—
—
—
—
—
—
—
02211061
2,150 (9,563)
02211062
02211063
2,860 (12,721) 3,130 (13,922)
6
—
—
—
—
—
—
—
—
—
02211072
2,245 (9,986)
02211033
2,970 (13,211)
02211073
2,245 (9,986)
Note: See page T-47 for multiple cables in a single conduit riser grip.
Dimensions in Inches (cm)
www.hubbell-wiring.com
T-39
Conduit Riser Grips
¾
Kellems® Wire Management Products
Kellems® Wire Management Products
Conduit Riser Grips
Ring Type, Double Weave, Tin-Coated Bronze
WARNING!
It is important that you read all breaking strength, safety
and technical data relating to this product on pages T-47
and T-48 .
Double Weave, Split Mesh, Lace Closing
Kellems® Conduit Riser Support Grips will support cable
runs in vertical or sloping standard rigid conduit . The grip
is fastened to a support ring which seats on the rim of the
conduit . The entire grip is supported by the conduit itself
and no other hardware is required . See page T-48 for
ring dimensions . The rings will fit schedule 40 rigid PVC
conduit and standard electrical rigid metal conduit only .
For permanent support when cable end is not available .
Suitable For Standard Electrical Rigid Metal Conduit and Schedule 40 Rigid PVC Conduit Only
Cable Sizes
Inches (cm)
Model
Conduit Riser Grips
Length
Inches (cm)
.75"- .99"
(1 .90-2 .51)
RS075
11" (27 .94)
1 .00"- 1 .24"
(2 .54-3 .15)
RS100
12" (30 .48)
1 .25"- 1 .49"
(3 .17-3 .78)
RS125
12" (30 .48)
1 .50"-1 .74"
(3 .81-4 .42)
RS150
14" (35 .56)
1 .75"- 1 .99"
(4 .44-5 .05)
RS175
15" (38 .10)
2 .00"- 2 .49"
(5 .08-6 .32)
RS200
17" (43 .18)
2 .50"- 2 .99"
(6 .35-7 .59)
RS250
18" (45 .72)
3 .00"- 3 .49"
(7 .62-8 .86)
RS300
20" (50 .80)
3 .50" -3 .99"
(8 .89-10 .13)
RS350
21" (53 .34)
Conduit Sizes
Inches
Catalog Number
Approx. Breaking Strength Lbs. (N)
1¼
02212003
1,580 (7,028)
—
—
—
—
—
—
—
—
1½
02212007
1,500 (6,672)
—
—
—
—
—
—
—
—
2
02212010 02212012 02212013
1,430 (6,361) 1,930 (8,585) 2,040 (9,074)
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
2½
—
—
02212017 02212018
1,910 (8,496) 2,040 (9,074)
3
—
—
02212023 02212024 02212025
02212026
1,780 (7,917) 1,890 (8,407) 2,520 (11,209) 4,300 (19,126)
3½
—
—
—
—
4
—
—
—
—
5
—
—
—
—
—
—
6
—
—
—
—
—
—
—
02212040
2,110 (9,385)
02212033
02212034
3,910 (17,392) 4,300 (19,126)
02212041
02212042
02212043
3,530 (15,701) 3,820 (16,991) 5,380 (23,930)
02212061
2,860 (12,721)
—
—
—
—
—
02212073
2,955 (13,144)
Note: See page T-47 for multiple cables in a single conduit riser grip.
T-40
www.hubbell-wiring.com
Dimensions in Inches (cm)
Kellems® Wire Management Products
Kellems® Wire Management Products
Conduit Riser Grips
Ring Type, Single Weave, Tin-Coated Bronze
WARNING!
It is important that you read all breaking strength, safety
and technical data relating to this product on pages T-47
and T-48 .
Single Weave, Split Mesh, Rod Closing Benefits
• Easy and fast to install.
• Will not damage electrical cable.
• Allows cable to expand or contract.
• Ideal way to hold cable in vertical conduit.
• Prevents cable creep in conduit.
• Helps prevent cable pullouts.
• The rings will fit schedule 40 rigid PVC conduit and
standard electrical rigid metal conduit only .
• For support when cable end is not available.
Suitable For Standard Electrical Rigid Metal Conduit and Schedule 40 Rigid PVC Conduit Only
Model
.75"- .99"
(1 .90-2 .51)
RR075
1 .00"- 1 .24" 1 .25"- 1 .49" 1 .50"- 1 .74" 1 .75"-1 .99"
(2 .54-3 .15) (3 .17-3 .78)
(3 .81-4 .42)
(4 .44-5 .05)
RR100
RR125
RR150
RR175
2 .00"- 2 .49"
(5 .08-6 .32)
RR200
2 .50"- 2 .99"
(6 .35-7 .59)
RR250
3 .00"-3 .49" 3 .50"-3 .99"
(7 .62-8 .86) (8 .89-10 .13)
RR300
RR350
Length
Inches (cm)
11" (27 .94)
12" (30 .48)
16" (40 .64)
18" (45 .72)
19" (48 .26) 21" (53 .34)
Cable Sizes
Inches (cm)
13" (33 .02)
14" (35 .56)
15" (38 .10)
Conduit Sizes Catalog Number
Inches
Approx. Breaking Strength Lbs. (N)
1¼
02213003
1,020 (4,537)
1½
02213007
970 (4,315)
—
02213009
1,610 (7,161)
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
2
—
02213012
02213013
1,520 (6,761) 1,610 (7,161)
2½
—
—
02213017
02213018
1,510 (6,716) 1,610 (7,161)
3
—
—
02213023
02213024
02213025
02213026
1,400 (6,227) 1,490 (6,627) 1,990 (8,851) 3,260 (14,500)
3½
—
—
—
—
—
02213033
2,970 (13,211)
4
—
—
—
—
—
02213041
02213042
2,670 (11,876) 2,890 (12,855)
Note: See page T-47 for multiple cables in a single conduit riser grip.
Dimensions in Inches (cm)
www.hubbell-wiring.com
T-41
Conduit Riser Grips
—
Kellems® Wire Management Products
Kellems® Wire Management Products
Technical Information
Support Grips
Kellems Support Grips
Kellems Support Grips are used to hold the weight of electrical cable as it hangs in a vertical, sloping or horizontal position .
Electrical cable must be supported, or its dead weight can cause excessive strain or pullout at the connections resulting
in power failure . Support grips also absorb additional strain from flexure, vibration, expansion and contraction . Kellems
Support Grips listed in this catalog are made of high grade, non-magnetic tin-coated bronze strand . Stainless steel grips,
made of alloy 302–304 SST for severe service or unusual environmental conditions, are available on request .
Select the Correct Support Grip
Each Kellems grip is designed to work on a specific
range of cable diameters .
Step 1 Refer to the Kellems chart below to determine
the grip style best suited for your application .
Step 2 Determine your cable outside diameter .
Step 3 Find the grip size that encompasses your
cable diameter .
Step 4 Whenever possible, use a closed mesh that
assembles over the cable end . If the cable end
is not available, use a split mesh .
Step 5 Where available, select an eye style that suits
your needs .
Step 6 Select the proper material—tinned bronze or
stainless steel* .
Step 7 Estimate the tension to be put on the grip,
establish the working load you require and
compare this to the listed approximate breaking
strength of the grip to insure that the grip will be
strong enough . Refer to page T-43 for safety
and working load considerations .
Support Grip Selection Chart
CAUTION: It is very important to comply with all of the
following precautions .
1 . Support grips are to be installed by a qualified individual
in accordance with all applicable national and local
safety, electrical and rigging codes .
2 . Ensure that the correct grip is selected for your specific
needs .
3 . Do not use a support grip for any application other than
supporting cable .
4 . Thoroughly examine the grip for damage . Do not use a
damaged grip .
5 . Ensure that the recommended work load of the grip is
suitable for the application . Never use grips at their
approximated rated breaking strength . A safety factor
of 10 is recommended for support grips .
6 . Do not alter grips in any way . For example, do not
flatten, straighten, bend or otherwise modify eye tubes,
hooks, and strand equalizers .
7 . Do not attach any type of hook, clamp or other hardware
directly to the stranded bale of a “U” eye support grip .
The formed eye tube is the only acceptable means of
attachment to external hardware .
8 . Always apply 2 bands at 1" and 2" respectively, from
the tail end of the mesh to guard against accidental
release of the grip . Accidental release can occur if an
object contracts and pushes against the tail end of the
mesh, thereby expanding and releasing it’s hold .
Grip Styles
Application
Page
Closed mesh
Split lace closing
Split rod closing
Standard, permanent support, cable end available .
Standard, permanent support, cable end unavailable .
Standard, temporary support, cable end unavailable . Tape or band tail
end of wire mesh grip after positioning for permanent support .
Tin-coated bronze standard or stainless steel by special request .
Support vertical runs to 99 ft . loads to 600 lbs .
Support vertical runs over 100 ft . loads over 600 lbs .
Light duty to support service entrance cable .
Light duty support, indoors only, on Bus drop cable .
Support cable runs in rigid (Schedule 40) conduit .
Support fiber optic cable .
T-30 to T-38
T-30 to T-35
T-30 to T-33
Material*
Standard support grips
Heavy duty grips
Service drop
Bus drop
Conduit riser
Fiber optic cable support grips
T-30 to T-41
T-30 to T-33
T-34, T-35
T-36, T-37
T-38
T-39 to T-41
T-53
Technical Information
Note: * Most catalog listed support grips are made of tin-coated bronze strand. To order stainless steel support grips, change the first three catalog number
digits from 022-0x-xxx to 024-0x-xxx. Consult Technical Service for details.
Eye Styles
Single
T-42
Double
Universal
www.hubbell-wiring.com
Offset
Dimensions in Inches (cm)
Technical Information
Support Grips
Safety And Working Load Factors For Wire Mesh Grips
The broad application of Kellems grips on a wide variety
of objects requires that adequate safety factors be used
to establish working loads . The approximate breaking
strength of a Kellems grip represents an average
calculation based on data established from actual direct
tension testing done in our engineering laboratories .
It is impossible to catalog or guarantee a safety factor
suitable for all applications as operating conditions are
never the same . The tension, diameter, movement,
number of objects gripped, gripping surface, and the
attachments used are just some of the factors which
vary with each application . These factors, together with
the effects of abrasion, corrosion, prior use or abuse
and any other variables of a specific application, must
be considered by the user and the grip replaced as
appropriate . Where the conditions of the application
are not well defined or known, or where risk of injury to
persons or property is involved, a greater safety factor
should be utilized .
Under normal conditions, Kellems’ recommended factor
of safety is five for catalog listed pulling grips, and ten
for catalog listed support grips.
Any warranty as to quality, performance or fitness for use
of grips is always premised on the condition that the
published breaking strengths apply only to new, unused
grips, and that such products are properly stored, handled,
used, maintained, and inspected by the user at a frequency
appropriate for the use and condition of the grip .
Kellems® Wire Management Products
Kellems® Wire Management Products
Examples
Grip Style
Approx. Breaking
Strength Lbs. (N)
Safety
Factor
Max. Rec.
Load Lbs. (N)
Catalog
Number
Pulling Grips
27,200 (120,986)
5
5,440 (24,197)
03301027
Support Grips
1,610 (7,161)
10
161 (716)
02202019
The maximum recommended working load is the tension to be exerted on the grip in application with a margin of safety
to take care of unforeseen and unusual circumstances .
It is the end-user’s decision to determine how much of a safety factor is acceptable for the application .
The metric unit of measure (force) for breaking strength and load is newtons (N) . To convert from newtons to the metric
unit of weight (kilograms) the conversion factor is 9 .808 newtons/kilogram .
Support Grip Materials
Material
Tin-coated bronze wire
Stainless steel wire (302-304)
Galvanized steel wire
Grip Type
• Support grips
• Service drop grips
• Conduit riser grips
• Support grips
• Hose containment grips
• Bus drop grips
Technical Information
Features
• Corrosion resistant for normal outside areas
• Non-magnetic
• Moderate strength
• High strength
• Corrosion resistant
• Slightly magnetic
• Not subject to continuous outside environment
Approvals
CSA Certifications are indicated on appropriate product catalog pages .
Note: It is always recommended that the tail end of the grip be banded after the installation on the cable to prevent accidental release of the mesh.
See page T-15 for end bands.
Dimensions in Inches (cm)
www.hubbell-wiring.com
T-43
Kellems® Wire Management Products
Kellems® Wire Management Products
Technical Information
Support Grips
Split Support Grip Lace Closing Instructions
Single Weave Grips should be laced with single strand lacing; double weave with double strand . Lacing
strands should be the same material as the grip . Kellems supplies the appropriate lacing with each grip .
1. Start the lacing at the lead or anchoring end of the grip . Thread the lacings through the first two loops of
the split and pull through until the lacings are centered at this point . Lace as you would your shoe,
crossing the lacings before lacing the next two loops .
2. Don’t pull lacing too tight . Leave a space between adjoining loops approximately equal to the width of
one diamond of the mesh .
3. Twist the lacing strands tightly together at the tail end of the grip .
4. Wrap the ends of the lacings once or twice tightly around the tail of the grip, twisting the ends together
securely . Excess lace can be cut off .
Technical Information
Split Support Grip Rod Closing Instructions
The stainless steel rod is a precise built-in feature which makes threading easy and fast . The strands of the
mesh pass around the rod and match up with the strands from the opposite direction . The rod does not
touch the cable at any point and therefore cannot cut the cable . Rod Closing Grips are reusable . They may
be removed and reused as many times as desired .
1. Fast to install
Wrap the grip around the cable and thread the rod through the pre-formed loops with a corkscrew motion,
using the curved end of the rod to engage the loops .
2. The action required is a steady push and twist simultaneously . The fingers of the left hand are used to
bring the loops together just ahead of the hook on the end of the rod .
3. To remove, simply pull the rod out .
T-44
www.hubbell-wiring.com
Dimensions in Inches (cm)
Technical Information
Bus Drop Grips
Bus Drop Grips and Safety Springs
Kellems Bus Drop Grips are offered with either a single eye or universal
bale attachment . The mesh is single weave galvanized steel with the
patented wide range construction . They are suitable for indoor use only .
Safety Spring
Strain
Relief
Grip
Bus
Drop
Grips
Strain
Relief
Grip
Motor Box
Application
Bus Drop Grips provide a safe, easy and economical method to support
flexible cord or bus drop cable at bus duct and other industrial areas .
Benefits
Kellems® Wire Management Products
Kellems® Wire Management Products
• Easily installed.
• Absorb tension, vibration and pull with no cable damage.
• Patented mesh construction.
Safety Spring
Springs can be used with single eye grips by disassembling drawbar
from coil, placing through eye and replacing drawbar .
Technical Information
Dimensions in Inches (cm)
www.hubbell-wiring.com
T-45
Kellems® Wire Management Products
Kellems® Wire Management Products
Technical Information
Support Grips
For Support Grips Only*
Multiple Cable Selection Charts for Cables and Wires of Unequal Diameters
How to choose the correct grip size:
1. Find the Grip Circumference Range by measuring the circumference
of the bundle of different diameter cables to be gripped (see illustration) .
2. Divide the bundle circumference by 3 .14 to determine the diameter .
3. Choose a grip offering a range of cable diameters the same as the
cable diameter .
For Cables of Equal Diameters
Under “Number of Cables in One Grip”, find the diameter of your single cable in vertical column . Read the grip diameter range to the right .
If your diameter is the maximum of the range shown, go to the next larger size for Split Grips, stay with the same size for Closed Grips .
Example: 3 cables, each with .89" (2 .26cm) diameter, for a Closed Grip select the 1 .50"-1 .74" (3 .81cm-4 .42cm) range, for a Split Grip
select the 1 .75"-1 .99" (4 .44cm-5 .05cm) range .
Conduit Riser Grips
Number of Cables in One Grip
2
3
4
5
6 and 7
8
9
Grip Dia. Range
Inches (cm)
.30- .38
( .76- .97)
.38- .44
( .97-1 .12)
.44- .59
(1 .12-1 .50)
.59- .75
(1 .50-1 .90)
.75- .90
(1 .90-2 .29)
.90-1 .07
(2 .29-2 .72)
1 .07-1 .22
(2 .72-3 .10)
1 .22-1 .53
(3 .10-3 .89)
1 .53-1 .83
(3 .89-4 .65)
1 .83-2 .14
(4 .65-5 .44)
2 .14-2 .44
(5 .44-6 .20)
2 .44-2 .75
(6 .20-6 .98)
2 .75-3 .06
(6 .98-7 .77)
.25- .31
( .63- .79)
.31- .36
( .79- .91)
.36- .49
( .91-1 .24)
.49- .63
(1 .24-1 .60)
.63- .76
(1 .60-1 .93)
.76- .89
(1 .93-2 .26)
.89-1 .02
(2 .26-2 .59)
1 .02-1 .28
(2 .59-3 .25)
1 .28-1 .53
(3 .25-3 .89)
1 .53-1 .79
(3 .89-4 .55)
1 .79-2 .05
(4 .55-5 .21)
2 .05-2 .30
(5 .21-5 .84)
2 .30-2 .56
(5 .84-6 .50)
.22- .27
( .56- .69)
.27- .31
( .69- .79)
.31- .42
( .79-1 .07)
.42- .54
(1 .07-1 .37)
.54- .65
(1 .37-1 .65)
.65- .77
(1 .65-1 .96)
.77- .88
(1 .96-2 .24)
.88-1 .10
(2 .24-2 .79)
1 .10-1 .32
(2 .79-3 .35)
1 .32-1 .54
(3 .35-3 .91)
1 .54-1 .76
(3 .91-4 .47)
1 .76-1 .98
(4 .47-5 .03)
1 .98-2 .20
(5 .03-5 .59)
.19- .24
( .48- .61)
.24- .29
( .61- .74)
.29- .38
( .74- .97)
.38- .48
( .97-1 .22)
.48- .58
(1 .22-1 .47)
.58- .67
(1 .47-1 .70)
.67- .77
(1 .70-1 .96)
.77- .96
(1 .96-2 .44)
.96-1 .16
(2 .44-2 .95)
1 .16-1 .35
(2 .95-3 .43)
1 .35-1 .54
(3 .43-3 .91)
1 .54-1 .74
(3 .91-4 .42)
1 .74-1 .93
(4 .42-4 .90)
.17- .22
( .43- .56)
.22- .26
( .56- .66)
.26- .34
( .66- .86)
.34- .43
( .86-1 .09)
.43- .52
(1 .09-1 .32)
.52- .60
(1 .32-1 .52)
.60- .69
(1 .52-1 .75)
.69- .86
(1 .75-2 .18)
.86-1 .03
(2 .18-2 .62)
1 .03-1 .20
(2 .62-3 .05)
1 .20-1 .37
(3 .05-3 .48)
1 .37-1 .55
(3 .48-3 .94)
1 .55-1 .72
(3 .94-4 .37)
.15- .19
( .38- .48)
.19- .23
( .48- .58)
.23- .31
( .58- .79)
.31- .39
( .79- .99)
.39- .46
( .99-1 .17)
.46- .54
(1 .17-1 .37)
.54- .62
(1 .37-1 .57)
.62- .77
(1 .57-1 .96)
.77- .93
(1 .96-2 .36)
.93-1 .08
(2 .36-2 .74)
1 .08-1 .24
(2 .74-3 .15)
1 .24-1 .39
(3 .15-3 .53)
1 .39-1 .55
(3 .53-3 .94)
.14- .18
( .36- .46)
.18- .21
( .46- .53)
.21- .28
( .53- .71)
.28- .35
( .71- .89)
.35- .42
( .89-1 .07)
.42- .49
(1 .07-1 .24)
.49- .56
(1 .24-1 .42)
.56- .71
(1 .42-1 .80)
.71- .85
(1 .80-2 .16)
.85- .99
(2 .16-2 .51)
.99-1 .13
(2 .51-2 .87)
1 .13-1 .27
(2 .87-3 .23)
1 .27-1 .41
(3 .23-3 .58)
.50- .61
(1 .27-1 .55)
.62- .74
(1 .57-1 .88)
.75- .99
(1 .90-2 .51)
1 .00-1 .24
(2 .54-3 .15)
1 .25-1 .49
(3 .17-3 .78)
1 .50-1 .74
(3 .81-4 .42)
1 .75-1 .99
(4 .44-5 .05)
2 .00-2 .49
(5 .08-6 .32)
2 .50-2 .99
(6 .35-7 .59)
3 .00-3 .49
(7 .62-8 .86)
3 .50-3 .99
(8 .89-10 .13)
4 .00-4 .49
(10 .16-11 .40)
4 .50-4 .99
(11 .43-12 .67)
Note: * This chart is to be used for determining grip size when multiple cables are held in a single Support Grip. For Conduit Riser multiple cable selection,
see page T-47. It is always recommended that, when multiple cables are installed in a Support Grip, the tail end of the grip be banded after installation
on the cable bundle.
T-46
www.hubbell-wiring.com
Dimensions in Inches (cm)
Kellems® Wire Management Products
Kellems® Wire Management Products
Technical Information
Conduit Riser Support Grips
For Conduit Riser Grips Only*
Multiple Cable Selection Charts for Cables and Wires of Unequal Diameters
How to choose the correct grip size:
1 . Find the Grip Circumference Range by measuring the circumference
of the bundle of different diameter cables to be gripped (see illustration) .
2 . Divide the bundle circumference by 3 .14 to determine the diameter .
3 . Choose a grip offering a range of cable diameters the same as the
cable diameter .
For Cables of Equal Diameters
Under “Number of Cables in One Grip”, find the diameter of your single cable in vertical column . Read the grip diameter range to the right .
If your diameter is the maximum of the range shown, go to the next larger size for Split Grips, stay with the same size for Closed Grips .
Example: 3 cables, each with .85" (2 .16cm) diameter, for a Closed Grip select the 1 .50"-1 .74" (3 .81cm-4 .42cm) range, for a Split Grip
select the 1 .75"-1 .99" (4 .44cm-5 .05cm) range .
Number of Equal Diameter Cables in One Grip
3
4
5
6 and 7
8
9
Grip Dia. Range
Inches (cm)
.29- .36
( .74- .91)
.37- .43
( .94-1 .09)
.44- .58
(1 .12-1 .47)
.59- .72
(1 .50-1 .83)
.73- .87
(1 .85-2 .21)
.88-1 .01
(2 .24-2 .57)
1 .02-1 .16
(2 .59-2 .95)
1 .17-1 .44
(2 .97-3 .66)
1 .45-1 .73
(3 .68-4 .39)
1 .74-2 .02
(4 .42-5 .13)
2 .03-2 .31
(5 .16-5 .87)
.24- .30
( .61- .76)
.31- .36
( .79- .91)
.37- .48
( .94-1 .22)
.49- .60
(1 .24-1 .52)
.61- .72
(1 .55-1 .83)
.73- .85
(1 .85-2 .16)
.86- .96
(2 .18-2 .44)
.97-1 .20
(2 .46-3 .05)
1 .21-1 .45
(3 .07-3 .68)
1 .46-1 .69
(3 .71-4 .29)
1 .70-1 .93
(4 .32-4 .90)
.21- .25
( .53- .63)
.26- .30
( .66- .76)
.31- .41
( .79-1 .04)
.42- .51
(1 .07-1 .30)
.52- .61
(1 .32-1 .55)
.62- .71
(1 .57-1 .80)
.72- .81
(1 .83-2 .06)
.82-1 .02
(2 .08-2 .59)
1 .03-1 .22
(2 .62-3 .10)
1 .23-1 .43
(3 .12-3 .63)
1 .44-1 .63
(3 .66-4 .14)
.18- .22
( .46- .56)
.23- .27
( .58- .69)
.28- .36
( .71- .91)
.37- .45
( .94-1 .14)
.46- .54
(1 .17-1 .37)
.55- .63
(1 .40-1 .60)
.64- .72
(1 .63-1 .83)
.73- .90
(1 .85-2 .29)
.91-1 .08
(2 .31-2 .74)
1 .09-1 .26
(2 .77-3 .20)
1 .27-1 .44
(3 .23-3 .66)
.16- .20
( .41- .51)
.21- .24
( .53- .61)
.25- .32
( .63- .81)
.33- .40
( .84-1 .02)
.41- .48
(1 .04-1 .22)
.49- .56
(1 .24-1 .42)
.57- .64
(1 .45-1 .63)
.65- .80
(1 .65-2 .03)
.81- .96
(2 .06-2 .44)
.97-1 .11
(2 .46-2 .82)
1 .12-1 .27
(2 .84-3 .23)
.15- .18
( .38- .46)
.19- .22
( .48- .56)
.23- .29
( .58- .74)
.30- .36
( .76- .91)
.37- .43
( .94-1 .09)
.44- .51
(1 .12-1 .30)
.52- .58
(1 .32-1 .49)
.59- .72
(1 .50-1 .83)
.73- .87
(1 .85-2 .21)
.83-1 .01
(2 .11-2 .57)
1 .02-1 .15
(2 .59-2 .92)
.14- .17
( .36- .43)
.18- .20
( .46- .51)
.21- .27
( .53- .69)
.28- .34
( .71- .86)
.35- .40
( .89-1 .02)
.41- .47
(1 .04-1 .19)
.48- .54
(1 .22-1 .37)
.55- .67
(1 .40-1 .70)
.68- .81
(1 .73-2 .06)
.82- .94
(2 .08-2 .39)
.95-1 .08
(2 .41-2 .74)
.50- .62
(1 .27-1 .57)
.63- .74
(1 .60-1 .88)
.75- .99
(1 .90-2 .51)
1 .00-1 .24
(2 .54-3 .15)
1 .25-1 .49
(3 .17-3 .78)
1 .50-1 .74
(3 .81-4 .42)
1 .75-1 .99
(4 .44-5 .05)
2 .00-2 .49
(5 .08-6 .32)
2 .50-2 .99
(6 .35-7 .59)
3 .00-3 .49
(7 .62-8 .86)
3 .50-3 .99
(8 .89-10 .13)
Note: * This chart is to be used for determining grip size when multiple cables are held in a single Conduit Riser Grip. For Support Grip multiple cable selection,
see page T-46. It is always recommended that, when multiple cables are installed in a Conduit Riser Grip, the tail end of the grip be banded after
installation on the cable bundle.
Dimensions in Inches (cm)
www.hubbell-wiring.com
T-47
Technical Information
2
Kellems® Wire Management Products
Kellems® Wire Management Products
Conduit Riser Grips
Conduit Riser Support Grip-Ring Dimensions
WARNING!
It is important that you read
all breaking strength, safety
and technical data relating
to this product on pages
T-41 through T-48 .
Conduit Ring Dimensions
Ring dimensions are found in the chart below . The ring material is
corrosion resistant . These rings will fit schedule 40 rigid PVC conduit
and standard electrical rigid metal conduit only .
O.D.
I.D.
T
Conduit Size ¾" and 1"
O.D.
I.D.
Conduit Size
Inches
Ring Number
O.D.
Inches (cm)
I.D.
Inches (cm)
S
Inches (cm)
T
Inches (cm)
¾
1
1¼
1½
2
2½
3
3½
4
4½
5
6
C-¾
C-1
C-1¼
C-1½
C-2
C-2½
C-3
C-3½
C-4
C-4½
C-5
C-6
.94" (2 .39)
1 .17" (2 .97)
1 .50" (3 .81)
1 .76" (4 .47)
2 .23" (5 .66)
2 .67" (6 .78)
3 .20" (8 .13)
3 .80" (9 .65)
4 .30" (10 .92)
4 .80" (12 .19)
5 .30" (13 .46)
6 .30" (16 .00)
.62" (1 .57)
.80" (2 .03)
1 .03" (2 .62)
1 .23" (3 .12)
1 .55" (3 .94)
2 .05" (5 .21)
2 .55" (6 .48)
3 .05" (7 .75)
3 .55" (9 .02)
4 .03" (10 .24)
4 .46" (11 .33)
5 .36" (13 .61)
—
—
1 .31" (3 .33)
1 .52" (3 .86)
1 .97" (5 .00)
2 .40" (6 .10)
2 .97" (7 .54)
3 .47" (8 .81)
3 .94" (10 .01)
4 .45" (11 .30)
4 .96" (12 .60)
5 .96" (15 .14)
.19" ( .48)
.19" ( .48)
.16" ( .41)
.16" ( .41)
.16" ( .41)
.16" ( .41)
.22" ( .56)
.22" ( .56)
.22" ( .56)
.22" ( .56)
.22" ( .56)
.25" ( .63)
T
T
S
Technical Information
Conduit Size 1¼" to 6"
T-48
www.hubbell-wiring.com
Dimensions in Inches (cm)
Kellems® Wire Management Products
Kellems® Wire Management Products
Fiber Optic Cable Grips
Pulling and Support Grips
OPTISOK® Grip is a revolutionary tool to pull
preterminated fiber optic cables . They will protect
the connectors and guide the bundle through the
pulling environment
Pulling Grips are used for outside plant cable .
They are easy to install and remove, reusable,
and have a slim profile for small build up
Grips for cable support are easy to install or position .
They come in a closed style when the cable end is
available, and a split rod style for mid-span installation .
Will support the cable’s weight as it hangs in vertical,
sloping or horizontal position
Fiber Optic Cable Grips
Dimensions in Inches (cm)
www.hubbell-wiring.com
T-49
Kellems® Wire Management Products
Kellems® Wire Management Products
Fiber Optic Cable Pulling Grips
Special Purpose
OPTISOK® Non-metallic Fiber Optic Pulling Tool For Preterminated,
Inside Plant Fiber Optic Cables and Bundles of Twisted Pair
WARNING!
It is important that you read
all breaking strength, safety
and technical data relating
to this product on pages
T-54 through T-57 .
OPTISOK® Non-Metallic Fiber Optic Pulling Tool
Bundle/Size
Range
Inches (cm)
Approx. O/A
Length
Inches (cm)
Ring
O.D.
Inches (cm)
Ring
Thickness
Inches (cm)
Maximum
Work Load
lbs. (N)
Catalog
Number
.125"- .562" ( .318-1 .427)
.250"- .750" ( .635-1 .905)
.750"-1 .750" (1 .905-4 .445)
28" (71 .12)
31" (78 .74)
33" (83 .82)
.71" (1 .803)
.71" (1 .803)
1 .57" (3 .988)
.10" ( .254)
.10" ( .254)
.16" ( .406)
30 (133)
40 (178)
50 (222)
CCPS1
CCPS2
CCPS3
Fiber Optic Cable Pulling Grips
Pulling Grip For Loose Tube Fiber Optic Cable, Galvanized Steel
Pulling Grip For Loose Tube Fiber Optic Cable, Galvanized Steel
Diameter
Range
Inches (cm)
Mesh
Length
Inches (cm)
Eye
Length
Inches (cm)
Eye
Diameter
Inches (cm)
Lug
Diameter
Inches (cm)
Maximum
Breaking Strength
lbs. (N)
Catalog
Number
.312"- .625" ( .79-1 .59)
22 .5" (57 .15)
6 .3" (16 .00)
.20" ( .51)
.51" (1 .30)
3,000 (13,344)
PFOLT312
T-50
www.hubbell-wiring.com
Dimensions in Inches (cm)
Fiber Optic Cable Pulling Grips
Double/Single Weave Mesh, Galvanized Steel, for Outside Plant Cable
WARNING!
It is important that you read
all breaking strength, safety
and technical data relating
to this product on pages
T-54 through T-57 .
F-O Pulling Grip, Flexible Eye
Cable
Diameter Range
Inches (cm)
Approx.
Breaking
Strength
Lbs. (N)
E
Approx.
Inches (cm)
M
Approx.
Inches (cm)
D
Approx.
Inches (cm)
Catalog
Number
.10"- .22" ( .25- .56)
1,000 (4,448)
5 .5" (14)
9" (23)
0 .8" (2)
033291000
.21"- .35" ( .53- .89)
1,500 (6,672)
5 .5" (14)
14" (36)
0 .8" (2)
033291001
.32"- .48" ( .81-1 .22)
2,200 (9,786)
6 .0" (15)
18" (46)
0 .9" (2 .29)
033291002
.42"- .61" (1 .07-1 .55)
2,800 (12,454)
6 .0" (15)
21" (53)
0 .9" (2 .29)
033291003
.53"- .74" (1 .35-1 .88)
3,300 (14,678)
6 .5" (17)
24" (61)
1 .3" (3 .30)
033291004
.64"- .87" (1 .63-2 .21)
4,700 (20,906)
6 .5" (17)
27" (69)
1 .3" (3 .30)
033291005
Kellems® Wire Management Products
Kellems® Wire Management Products
F-O Pulling Grip, Swivel Eye
Approx.
Breaking
Strength
Lbs. (N)
E
Approx.
Inches (cm)
M
Approx.
Inches (cm)
D
Approx.
Inches (cm)
Catalog
Number
.21"- .35" ( .53- .89)
1,500 (6,672)
4 .0" (10 .16)
14" (35 .56)
0 .9" (2 .29)
033291008
.32"- .48" ( .81-1 .22)
2,200 (9,786)
4 .0" (10 .16)
18" (45 .72)
0 .9" (2 .29)
033291009
.42"- .61" (1 .07-1 .55)
2,800 (12,454)
4 .0" (10 .16)
21" (53 .34)
0 .9" (2 .29)
033291010
.53"- .74" (1 .35-1 .88)
3,300 (14,678)
4 .5" (11 .43)
24" (60 .96)
1 .3" (3 .30)
033291011
.64"- .87" (1 .63-2 .21)
4,700 (20,906)
4 .5" (11 .43)
27" (68 .58)
1 .3" (3 .30)
033291012
Fiber Optic Cable Pulling Grips
Cable
Diameter Range
Inches (cm)
Note: E-Eye length.
M-Mesh length at nominal diameter.
Dimensions in Inches (cm)
www.hubbell-wiring.com
T-51
Kellems® Wire Management Products
Kellems® Wire Management Products
Fiber Optic Cable Pulling Grips
Galvanized Steel for Outside Plant Cable
WARNING!
It is important that you read
all breaking strength, safety
and technical data relating
to this product on pages
T-54 through T-57 .
F-O Pulling Grip, Flexible Eye, Low Profile, Double/Single Weave Mesh
Cable
Diameter Range
Inches (cm)
Approx.
Breaking
Strength
Lbs. (N)
E
Approx.
Inches (cm)
M
Approx.
Inches (cm)
Catalog
Number
.10"- .22 ( .25- .56)
900 (4,003)
7 .5" (19)
10" (25)
033291193
.21"- .35" ( .53- .89)
1,400 (6,227)
7 .5" (19)
14" (36)
033291194
.32"- .48" ( .81-1 .22)
2,000 (8,896)
8 .5" (22)
19" (48)
033291195
.42"- .61" (1 .07-1 .55)
2,500 (11,120)
8 .5" (22)
21" (53)
033291196
.53"- .74" (1 .35-1 .88)
3,000 (13,344)
8 .5" (22)
23" (58)
033291197
.64"- .87" (1 .63-2 .21)
4,200 (18,682)
8 .5" (22)
25" (64)
033291198
.75"-1 .00" (1 .90-2 .54)
4,200 (18,682)
8 .5" (22)
28" (71)
033291199
Fiber Optic Cable Pulling Grips
F-O Slack Pulling Grip, Split Mesh Rod Closing, Single Weave
Cable
Diameter Range
Inches (cm)
Approx.
Breaking
Strength
Lbs. (N)
E
Approx.
Inches (cm)
M
Approx.
Inches (cm)
Catalog
Number
.25"- .37" ( .63- .94)
300 (1,334)
3" (7 .6)
4 .7" (12)
033291015
.38"- .49" ( .97-1 .24)
800 (3,558)
3" (7 .6)
5" (13)
033291016
.50"- .61" (1 .27-1 .55)
800 (3,558)
3" (7 .6)
7 .5" (19)
033291017
.62"- .74" (1 .57-1 .88)
1,200 (5,338)
3" (7 .6)
8" (20)
033291018
Note: E-Eye length.
M-Mesh length at nominal diameter.
T-52
www.hubbell-wiring.com
Dimensions in Inches (cm)
Fiber Optic Cable Support Grips
Single Weave, Tin-Coated Bronze
F-O Single Eye Cable Support Grip, Closed Mesh, Single Weave
Cable
Diameter Range
Inches (cm)
Approx.
Breaking
Strength
Lbs. (N)
E
Approx.
Inches (cm)
M
Approx.
Inches (cm)
Catalog
Number
.18"- .25" ( .46- .63)
300 (1,334)
3" (7 .6)
1 .7" (4 .3)
022291000
.23"- .32" ( .58- .81)
300 (1,334)
3" (7 .6)
2 .5" (6 .4)
022291001
.30"- .39" ( .76- .99)
300 (1,334)
4" (10)
2 .5" (6 .4)
022291002
.37"- .48" ( .94-1 .22)
300 (1,334)
5" (13)
4" (10)
022291003
.46"- .58" (1 .17-1 .47)
400 (1,779)
6" (15)
4" (10)
022291004
.56"- .71" (1 .42-1 .80)
600 (2,669)
7" (18)
5 .5" (14)
022291005
.69"- .88" (1 .75-2 .24)
800 (3,558)
8" (20)
6" (15)
022291006
F-O Single Eye Cable Support Grip, Split Mesh, Rod Closing,
Single Weave
Cable
Diameter Range
Inches (cm)
Approx.
Breaking
Strength
Lbs. (N)
E
Approx.
Inches (cm)
M
Approx.
Inches (cm)
Catalog
Number
.18"- .25" ( .46- .63)
300 (1,334)
3" (7 .6)
2 .5" (6 .4)
022291016
.23"- .32" ( .58- .81)
300 (1,334)
3" (7 .6)
2 .5" (6 .4)
022291017
.30"- .39" ( .76- .99)
300 (1,334)
4" (10)
2 .5" (6 .4)
022291018
.37"- .48" ( .94-1 .22)
300 (1,334)
5" (13)
4" (10)
022291019
.46"- .58" (1 .17-1 .47)
400 (1,779)
6" (15)
5" (13)
022291020
.56"- .71" (1 .42-1 .80)
600 (2,669)
7" (18)
5" (13)
022291021
.69"- .88" (1 .75-2 .24)
800 (3,558)
8" (20)
6" (15)
022291022
WARNING!
It is important that you read
all breaking strength, safety
and technical data relating
to this product on pages
T-54 through T-57 .
For permanent support
when cable end is available
to be installed through grip .
Single Eye, Closed Mesh,
Single Weave
For support when cable end
not available .
Fiber Optic Cable Support Grips
Note: E-Eye length.
M-Mesh length at nominal diameter.
Single Eye, Split Mesh,
Rod Closing, Single Weave
Dimensions in Inches (cm)
www.hubbell-wiring.com
Kellems® Wire Management Products
Kellems® Wire Management Products
T-53
Kellems® Wire Management Products
Kellems® Wire Management Products
Technical Information
Fiber Optic Pulling and Support Grips
Kellems has wide experience with grips for the new
technology of fiber optic cable . As the industry leader in
producing wire mesh grips for the stringent requirements
of fiber optic applications, Kellems has developed several
series of grips for use with fiber optic communications cable .
Select the Correct Fiber Optic Grip
These grips include pulling grips with built in swivels, grips
with steel ends to protect fragile cable ends, grips with low
profiles to pull cables in tight places and the OPTISOK® an
effective tool to place preterminated cables . Also available
are grips to support fiber optic cable .
Step 3 Whenever possible, use a closed mesh that assembles
over the cable end . If the cable end is not available, use
a split mesh .
Each Kellems grip is designed to work on a specific range of
cable diameters .
Step 1 Determine your cable outside diameter .
Step 2 Find the grip size that encompasses your cable diameter .
Step 4 Where available, select an eye style that suits your needs .
Step 5 Estimate the tension to be put on the grip, establish the
working load you require and compare this to the listed
approximate breaking strength of the grip to insure that
the grip will be strong enough .
Safety And Working Load Factors For Wire Mesh Grips
The broad application of Kellems grips on a wide variety
of objects requires that adequate safety factors be used to
establish working loads . The approximate breaking strength
of a Kellems grip represents an average calculation based
on data established from actual direct tension testing done
in our engineering laboratories .
It is impossible to catalog or guarantee a safety factor
suitable for all applications as operating conditions are
never the same . The tension, diameter, movement, number
of objects gripped, gripping surface, and the attachments
used are just some of the factors which vary with each
application . These factors, together with the effects of
abrasion, corrosion, prior use or abuse and any other
variables of a specific application, must be considered by
the user and the grip replaced as appropriate . Where the
conditions of the application are not well defined or known
or where risk of injury to persons or property is involved, a
greater safety factor should be utilized .
Under normal conditions, Kellems’ recommended factor
of safety is five for catalog listed pulling grips, and ten
for catalog listed support grips.
Any warranty as to quality, performance or fitness for
use of grips is always premised on the condition that the
published breaking strengths apply only to new, unused
grips, and that such products are properly stored, handled,
used, maintained and inspected by the user at a frequency
appropriate for the use and condition of the grip .
For grip applications on materials other than those that
the grips have been specifically designed for, consult the
factory .
Examples
Grip Style
Approx. Breaking
Strength Lbs. (N)
Safety
Factor
Max. Rec.
Load Lbs. (N)
Catalog
Number
Pulling Grips
Support Grips
2,500 (11,120)
400 (1,779)
5
10
500 (2,224)
40 (178)
033291196
022291004
The maximum recommended working load is the tension to be exerted on the grip in application with a margin of safety to take care of
unforeseen and unusual circumstances.
It is the end-user’s decision to determine how much of a safety factor is acceptable to for the application.
Technical Information
Fiber Optic Grip Materials
Material
Features
Product Group
Galvanized steel wire
• High strength
• Not subject to continuous outside environment
• Pulling grips
Tin-coated bronze wire
• Corrosion resistant for normal outside areas
• Non-magnetic
• Moderate strength
• Support grips
Non-metallic braid
• Superior flex life
• Non-conductive
• Corrosion resistant
• Moderate strength
• OPTISOK®
Approvals
CSA Certification is indicated on appropriate product catalog pages .
T-54
www.hubbell-wiring.com
Dimensions in Inches (cm)
Kellems® Wire Management Products
Kellems® Wire Management Products
Technical Information
OPTISOK® Pulling Grips
Kellems offers a unique and simple to use tool
for the installation of preconnectorized fiber optic
cables, jumpers and bundles of twisted pair
communication cables - the OPTISOK® .
The OPTISOK® is a highly flexible and expandable
nonmetallic sleeve open on one end and with a
pulling ring on the other . It will expand to enclose
the larger group of fiber optic connectors and grab
the cable below the connector bundle by wrapping
and taping to provide a gripping tool that will grab
the cable(s) below the connectors . The pulling ring
can be attached to a pulling line or fish tape and the
OPTISOK® will act as the pulling tool .
OPTISOK® will contain and protect the connector
bundle and save time and labor by making the
pulling job easier, protecting the connectors from
possible damage during the pull and facilitating the
passage of the connector bundle through cramped
and tight spaces . The OPTISOK® can be used to
pull cables through plenums, underfloor duct, office
partitions, raised access floors and conduits . Three
sizes are available for all applications .
1
2
How to Select OPTISOK®
• Identify connector bundle diameter to be inserted into
the OPTISOK® .
• Choose appropriate catalog number based on size range.
Installation Information
Step 1. Expand open end of OPTISOK® and gently work in fiber
optic connector bundle .
Step 2. Still gently, work connector bundle up to the forward
section of the OPTISOK® .
Step 3. Starting at approximately 6" (15 .2cm) from tail end of
OPTISOK®, tightly fold over the OPTISOK® around cables
and tape wrapped section 3" (7 .62cm) past tail end onto
the bundle .
3
Step 4. Securely attach pulling line or tape to pulling ring .
Technical Information
Note To remove OPTISOK® carefully unwrap tape and slide out cables and
connectors or cut OPTISOK® away without damaging connectors
or cables.
4
Dimensions in Inches (cm)
www.hubbell-wiring.com
T-55
Kellems® Wire Management Products
Kellems® Wire Management Products
Technical Information
Fiber Optic Pulling Grips
Pulling Grip for Loose Tube Fiber Optic Cable
Kellems offers a wire mesh specifically designed to pull loose tube fiber optic cable and meet the special
pulling requirements recommended by fiber optic cable manufacturers .
Many fiber optic cable manufacturers require special cable preparation prior to pulling where a short section
of the outer jacket is stripped off exposing the aramid strength member . This creates two cable diameters,
one including the jacket and a second smaller diameter at the strength member . Kellems fiber grip with its
special weave will accommodate and securely grab both diameters, at the outside jacket and the internal
aramid strength member .
Additionally, this galvanized steel mesh grip has longer leads at the pulling eye to facilitate pulling the cable
up through the top, a very low profile lug and eye to slip through tight areas, and short shoulders to protect
the cable while maintaining the slim profile .
The grip can be used to pull cable overhead as well as underground through conduit and duct . It easily mates
with a swivel and has the necessary strength to securely make pulls .
Application Information
• Prior to pulling cable, follow cable manufacturers’ cable preparation recommendations.
• Never exceed cable manufacturers’ pulling tension recommendations.
• Never use grips to approximate breaking strength safety factor of 5 recommended.
Pulling Grips for Other Outside Plant Cables,
Swivel Eye, Flexible Eye, Split Style, Low Profile
Kellems Pulling Grips for fiber optic cable are made of high strength galvanized steel strand . They feature
a multiweave mesh, with one-half the mesh length double weave, and the second half single weave . This
special weave provides positive holding power while allowing the grip to remain flexible with no damage to
the cable jacket . Added features include a steel nose cone which protects the cable end and allows the grip
to pass easily through conduit and enclosures . The eye connects easily to a swivel or a pulling line . Several
grip sizes are available to accommodate all diameters of fiber optic cable .
Application
Kellems Flexible Eye Pulling Grips for fiber optic cable are used for the installation of fiber optic
communication lines either underground, overhead, through conduit or through enclosures . They will fit
single cables or cable bundles, are easily installed on the cable, and are reusable .
Technical Information
Benefits
•
•
•
•
•
High strength multiweave mesh for positive holding power.
Highly flexible mesh to follow the pulling path of the cable.
Steel nose cone reduces snags and hang-ups and protects cable end.
Easily installed and removed.
A dependable, reusable pulling tool.
T-56
www.hubbell-wiring.com
Dimensions in Inches (cm)
Technical Information
Fiber Optic Support Grips
Support Grips for Fiber Optic Cable
Kellems Support Grips for fiber optic cable are specially designed to hold the cable weight as it hangs in a
vertical or horizontal position . Fiber optic cable must be supported and Kellems Grips provide the support
easily and economically .
These grips are made of high grade, non-magnetic tin-coated bronze strand . They are offered in universal
bale or single eye configurations and are available in either closed mesh (for use where the cable end is
available) or in split mesh, rod closing (for installation on existing cable runs or at specific locations) .
Split Support Grip Rod Closing Instructions
The stainless steel rod is a precise built-in feature which makes threading easy and fast . The strands of the
mesh pass around the rod and match up with the strands from the opposite direction . The rod does not
touch the cable at any point and therefore cannot cut the cable . Rod Closing Grips are reusable . They may
be removed and reused as many times as desired .
Kellems® Wire Management Products
Kellems® Wire Management Products
Fast to Install
Step 1. Wrap the grip around the cable and thread the rod through the preformed loops with a corkscrew
motion, using the curved end of the rod to engage the loops .
Step 2. The action required is a steady push and twist simultaneously . The fingers of the left hand are used
to bring the loops together just ahead of the hook on the end of the rod .
Step 3. To remove, simply pull the rod out .
Technical Information
Dimensions in Inches (cm)
www.hubbell-wiring.com
T-57
Kellems® Wire Management Products
Kellems® Wire Management Products
Hose Containment Grips
WARNING!
It is important that you read all breaking strength,
safety and technical data relating to this product
on pages T-42 through T-43 .
Types of Attachment
The five attachment methods shown below provide
unlimited flexibility of attachment to meet any
condition .
Type E
Double Eye Grip, used where fastening is made with
eyebolts or similar anchor terminations .
Type A
Single Eye Grip, used where fastening MUST be made
from one point .
Type U
Universal Bale Grip, used to fasten around a structure or
closed eye .
Type Y
Threaded bolt (⁵⁄₁₆-18 x 1½" long), used to fasten through
drilled holes in plate .
Type F
Hose Containment Grips
Split fitting to fit AN-818 nuts . Fitting is positioned over
nut and located with internal flange . A hose clamp is
furnished and required to hold the fitting in correct
position .
Note: It should be emphasized that Kellems® Hose Containment Grips are not to be used as a pressure reinforcing device for hose systems. These grips are
custom made. Consult Technical Services for details.
Kellems Hose Containment Grips are used on high pressure, flexible hose lines to prevent the hose from whipping
violently in the event of hose failure at the fitting . These grips will prevent serious injury to personnel and damage
to equipment by holding the hose in place in the event of hose failure .
Kellems patented Hose Containment Grips are made of stainless steel with double weave mesh construction for
high strength and come complete with hose clamps .
Kellems Hose Containment Grips are supplied in diameters, length and attachments to meet individual requirements .
Contact the Wiring Device-Kellems factory for specific information . These grips help meet OSHA Federal Register
1926-302 (b), 1926-603 (9), (10), JIC H-1-1973 (H13 .11) and JIC P-1-1975 (P11 .34) requirements .
T-58
www.hubbell-wiring.com
Dimensions in Inches (cm)
Kellems® Wire Management Products
Kellems® Wire Management Products
Strain Relief for Flexible Cords
For Insulated Cables and Flexible, Liquidtight Conduits
Endless weave provides easy cable/flexible conduit installation
Stainless steel mesh is corrosion resistant . Can be used inside or
outside. It eliminates cable or flexible conduit pull out and reduces
costly downtime
Multiweave grip gives cable arc-of-bend control minimizing cable
damage and extending cable life . It is the strongest strain relief
device available . Meets and exceeds all code requirements;
prevents cable/conduit pull-out
Strain Relief for Flexible Cords
A liquidtight fitting is available with both cable and conduit fittings;
prevents liquids from running through the fitting into the enclosure
An N .P .T . and PG threaded body allows easy attachment to either threaded
hub or knock-out in box
Dimensions in Inches (cm)
www.hubbell-wiring.com
T-59
Kellems® Wire Management Products
Kellems® Wire Management Products
Deluxe Cord Grips
Aluminum Fittings, Stainless Steel Mesh, Liquidtight, for Insulated Cables
WARNING!
It is important that you read
all breaking strength, safety
and technical data relating
to this product on pages
T-71 through T-76 .
Straight Male Thread
N.P.T. Thread
Size Inches
³⁄₈
½
½
¾
¾
1
Straight Male
1
1¼
1½
1½
2
Deluxe Cord Grips
2
Note: Kellems® Deluxe Cord Grips are suitable
for use in hazardous locations per Class I
Div. 2, Class II Div. 1 & 2, Class III Div. 1 &
2 of the National Electric Code Sections
501.10(b)(2), 502.10(a)(2), 502.10(b)(2),
503.10(a)(2) and 503.10(b).
2½
3
* Cable jacket may have to be stripped to
pass through connector body.
3
T-60
Grip Diameter Range
Inches
(cm)
.250"- .312"
.312"- .375"
.375"- .437"
.187"- .250"
.250"- .375"
.375"- .500"
.500"- .625"
.625"- .750"
.750"- .875"
.187"- .250"
.250"- .375"
.375"- .500"
.500"- .625"
.625"- .750"
.750"- .875"
.375"- .500"
.500"- .625"
.625"- .750"
.750"- .875"
.875"-1 .000"
1 .000"-1 .125"
1 .125"-1 .250"
1 .250"-1 .375"
.750"- .875"
.875"-1 .000"
1 .000"-1 .125"
1 .125"-1 .250"
1 .250"-1 .375"
.750"- .875"
.875"-1 .000"
1 .000"-1 .125"
1 .125"-1 .250"
1 .250"-1 .375"
1 .312"-1 .437"
1 .437"-1 .562"
1 .562"-1 .687"
1 .687"- 1 .812"
1 .750"-1 .875"
1 .250"-1 .375"
1 .312"-1 .437"
1 .437"-1 .562"
1 .562"-1 .687"
1 .687"-1 .812"
1 .750"- 1 .875"
1 .812"-1 .937"
1 .937"-2 .062"
2 .062"-2 .187"
2 .187"-2 .312"
2 .312"-2 .437"
1 .688"-1 .812"
1 .812"-1 .937"
1 .937"-2 .062"
2 .062"-2 .187"
2 .187"-2 .312"
2 .312"-2 .437"
1 .937"-2 .062"
2 .062"-2 .187"
2 .187"-2 .312"
2 .312"-2 .437"
2 .437"-2 .625"
2 .625"-2 .812"
2 .812"-3 .000"
3 .000"-3 .250"
( .63- .79)
( .79- .95)
( .95-1 .11)
( .47- .63)
( .63- .95)
( .95-1 .27)
(1 .27-1 .59)
(1 .59-1 .90)
(1 .90-2 .22)
( .47- .63)
( .63- .95)
( .95-1 .27)
(1 .27-1 .59)
(1 .59-1 .90)
(1 .90-2 .22)
( .95-1 .27)
(1 .27-1 .59)
(1 .59-1 .90)
(1 .90-2 .22)
(2 .22-2 .54)
(2 .54-2 .86)
(2 .86-3 .17)
(3 .17-3 .49)
(1 .90-2 .22)
(2 .22-2 .54)
(2 .54-2 .86)
(2 .86-3 .17)
(3 .17-3 .49)
(1 .90-2 .22)
(2 .22-2 .54)
(2 .54-2 .86)
(2 .86-3 .17)
(3 .17-3 .49)
(3 .33-3 .65)
(3 .65-3 .97)
(3 .97-4 .28)
(4 .28-4 .60)
(4 .44-4 .76)
(3 .17-3 .49)
(3 .33-3 .65)
(3 .65-3 .97)
(3 .97-4 .28)
(4 .28-4 .60)
(4 .44-4 .76)
(4 .60-4 .92)
(4 .92-5 .24)
(5 .24-5 .55)
(5 .55-5 .87)
(5 .87-6 .19)
(4 .29-4 .60)
(4 .60-4 .92)
(4 .92-5 .24)
(5 .24-5 .55)
(5 .55-5 .87)
(5 .87-6 .19)
(4 .92-5 .24)
(5 .24-5 .55)
(5 .55-5 .87)
(5 .87-6 .19)
(6 .19-6 .67)
(6 .67-7 .14)
(7 .14-7 .62)
(7 .62-8 .25)
www.hubbell-wiring.com
Form
Size
F1
F2
F3
F2
F3
F4
F5
F5
F5
F6
F6
F7
F7
F7
F8
Catalog Number
07401001
07401002
07401003
07401004
07401006
07401008
07401010
074011247*
074011248*
07401011
07401013
07401015
07401017
07401018
074011249*
074011195
07401019
07401021
07401023
07401025
074011250*
074011028*
074011029*
074011251
07401026
07401027
07401028
074011178*
074011252
07401029
07401030
07401031
07401032
074011253
074011254*
074011255*
074011256*
074011257*
074011258
074011259
07401033
07401034
07401035
074011260
074011261
074011262*
074011263*
074011264*
074011265*
074011030
074011031
074011032
074011033
074011034
074011266*
074011036
074011037
074011038
074011039
074011186
074011187
074011188
074011189*
Dimensions in Inches (cm)
Deluxe Cord Grips
Aluminum Fittings, Stainless Steel Mesh, Liquidtight, for Insulated Cables
Straight Female Thread
N.P.T. Thread
Size Inches
Grip Diameter Range
Inches
(cm)
½
.375"- .500"
.500"- .625"
.500"- .625"
.625"- .750"
¾
¾
( .95-1 .27)
(1 .27-1 .59)
(1 .27-1 .59)
(1 .59-1 .90)
Form
Size
F2
F2
F4
Catalog Number
07401043
07401045
07401052
07401053
WARNING!
It is important that you read
all breaking strength, safety
and technical data relating
to this product on pages
T-71 through T-76 .
90° Male Thread
N.P.T. Thread
Size Inches
³⁄₈
½
¾
1
1¼
1½
2
Grip Diameter Range
Inches
(cm)
.250"- .312"
.312"- .375"
.375"- .437"
.187"- .250"
.250"- .375"
.375"- .500"
.500"- .625"
.375"- .500"
.500"- .625"
.625"- .750"
.750"- .875"
.500"- .625"
.625"- .750"
.750"- .875"
.875"-1 .000"
1 .000"-1 .125"
.750"- .875"
.875"-1 .000"
1 .000"-1 .125"
1 .125"-1 .250"
1 .000"-1 .125"
1 .125"-1 .250"
1 .250"-1 .375"
1 .312"-1 .437"
1 .437"-1 .562"
1 .687"-1 .812"
1 .750"-1 .875"
( .63- .79)
( .79- .95)
( .95-1 .11)
( .47- .63)
( .63- .95)
( .95-1 .27)
(1 .27-1 .59)
( .95-1 .27)
(1 .27-1 .59)
(1 .59-1 .90)
(1 .90-2 .22)
(1 .27-1 .59)
(1 .59-1 .90)
(1 .90-2 .22)
(2 .22-2 .54)
(2 .54-2 .86)
(1 .90-2 .22)
(2 .22-2 .54)
(2 .54-2 .86)
(2 .86-3 .17)
(2 .54-2 .86)
(2 .86-3 .17)
(3 .17-3 .49)
(3 .33-3 .65)
(3 .65-3 .97)
(4 .28-4 .60)
(4 .44-4 .76)
Form
Size
F1
F2
F3
F4
F5
F5
F6
Catalog Number
07401071
07401072
07401073
07401074
07401076
07401078
07401080*
07401081
07401083
07401084*
074011275*
07401085
07401087
07401089
07401091*
074011229*
074011230
07401137
07401108
074011042*
074011045
074011046
074011047
074011233
074011244
074011246
074011234*
Kellems® Wire Management Products
Kellems® Wire Management Products
Straight Female
90º Male
45° Male Thread
N.P.T. Thread
Size Inches
½
¾
1¼
.250"- .375"
.375"- .500"
.500"- .625"
.500"- .625"
.625"- .750"
.750"- .875"
.625"- .750"
.750"- .875"
.875"-1 .000"
1 .000"-1 .125"
1 .125"-1 .250"
( .63- .95)
( .95-1 .27)
(1 .27-1 .59)
(1 .27-1 .59)
(1 .59-1 .90)
(1 .90-2 .22)
(1 .59-1 .90)
(1 .90-2 .22)
(2 .22-2 .54)
(2 .54-2 .86)
(2 .86-3 .17)
Form
Size
F2
F3
F4
F5
Catalog Number
074011236
074011021
074011237*
074011049
074011051*
074011239*
074011055
074011057
074011199*
074011059
074011060
45º Male
Note: Kellems® Deluxe Cord Grips are suitable
for use in hazardous locations per Class I
Div. 2, Class II Div. 1 & 2, Class III Div. 1 &
2 of the National Electric Code Sections
501.10(b)(2), 502.10(a)(2), 502.10(b)(2),
503.10(a)(2) and 503.10(b).
* Cable jacket may have to be stripped to
pass through connector body.
Dimensions in Inches (cm)
www.hubbell-wiring.com
T-61
Deluxe Cord GrIps
1
Grip Diameter Range
Inches
(cm)
Kellems® Wire Management Products
Kellems® Wire Management Products
Deluxe Cord Grips
Nylon Fittings, Stainless Steel Mesh, Liquidtight, for Insulated Cables
WARNING!
It is important that you read
all breaking strength, safety
and technical data relating
to this product on pages
T-71 through T-76 .
Straight Male Thread
N.P.T. Thread
Size Inches
½
¾
1
Grip Diameter Range
Inches
(cm)
.187"- .250"
.250"- .375"
.375"- .500"
.500"- .625"
.375"- .500"
.500"- .625"
.625"- .750"
.750"- .875"
.625"- .750"
.750"- .875"
.875"-1 .000"
1 .000"-1 .125"
( .47- .63)
( .63- .95)
( .95-1 .27)
(1 .27-1 .59)
( .95-1 .27)
(1 .27-1 .59)
(1 .59-1 .90)
(1 .90-2 .22)
(1 .59-1 .90)
(1 .90-2 .22)
(2 .22-2 .54)
(2 .54-2 .86)
Form
Size
F2
F3
F4
Catalog Number
074011331
074011332
074011333
074011334*
074011335
074011336
074011337
074011338*
074011341
074011342
074011343
074011344*
Straight Male
90° Male Thread
N.P.T. Thread
Size Inches
½
¾
Grip Diameter Range
Inches
(cm)
.250"- .375"
.375"- .500"
.500"- .625"
.375"- .500"
.500"- .625"
.625"- .750"
( .63- .95)
( .95-1 .27)
(1 .27-1 .59)
( .95-1 .27)
(1 .27-1 .59)
(1 .59-1 .90)
Form
Size
F2
F3
Catalog Number
074011346
074011347
074011348*
074011349
074011350
074011351*
Deluxe Cord Grips
90º Male
Note: Kellems® Deluxe Cord Grips are suitable
for use in hazardous locations per Class I
Div. 2, Class II Div. 1 & 2, Class III Div. 1 &
2 of the National Electric Code Sections
501.10(b)(2), 502.10(a)(2), 502.10(b)(2),
503.10(a)(2) and 503.10(b).
* Cable jacket may have to be stripped to
pass through connector body.
T-62
www.hubbell-wiring.com
Dimensions in Inches (cm)
Deluxe Cord Grips
Nylon Fittings, Non-metallic Mesh, Liquidtight, for Insulated Cables and
Stainless Steel Fittings, Stainless Steel Mesh, Liquidtight, for Insulated Cables
Nylon Fittings Non-metallic Mesh, Liquidtight for Insulated Cables
Straight Male Thread
N.P.T. Thread
Size Inches
³⁄₈
½
¾
1
Grip Diameter Range
Inches
(cm)
.187"- .250"
.250"- .312"
.312"- .375"
.187"- .250"
.250"- .375"
.375"- .500"
.375"- .500"
.500"- .625"
.625"- .750"
.500"- .625"
.625"- .750"
.750"- .875"
.875"-1 .000"
( .47- .63)
( .63- .79)
( .79- .95)
( .47- .63)
( .63- .95)
( .95-1 .27)
( .95-1 .27)
(1 .27-1 .59)
(1 .59-1 .90)
(1 .27-1 .59)
(1 .59-1 .90)
(1 .90-2 .22)
(2 .22-2 .54)
Form
Size
F1
F2
F3
F4
WARNING! It is important that
you read
all breaking strength, safety
and technical data relating
to this product on pages
T-71 through T-76 .
Catalog Number
CG304NM
CG305NM
CG306NM
CG404NM
CG406NM
CG408NM
CG608NM
CG610NM
CG612NM
CG810NM
CG812NM
CG814NM
CG816NM
Kellems® Wire Management Products
Kellems® Wire Management Products
Straight Male
90° Male Thread
N.P.T. Thread
Size Inches
Grip Diameter Range
Inches
(cm)
½
.250"- .375"
.375"- .500"
.375"- .500"
.500"- .625"
.625"- .750"
.625"- .750"
.750"- .875"
¾
1
( .63- .95)
( .95-1 .27)
( .95-1 .27)
(1 .27-1 .59)
(1 .59-1 .90)
(1 .59-1 .90)
(1 .90-2 .22)
Form
Size
F2
F3
F4
Catalog Number
CG40690NM
CG40890NM
CG60890NM
CG61090NM
CG61290NM*
CG81290NM
CG81490NM
90º Male
Stainless Steel Fittings, Stainless Steel Mesh,
Liquidtight for Insulated Cables
Straight Male Thread
N.P.T. Thread
Size Inches
½
¾
1
.187"- .250"
.250"- .375"
.375"- .500"
.500"- .625"
.375"- .500"
.500"- .625"
.625"- .750"
.750"- .875"
.500"- .625"
.625"- .750"
.750"- .875"
.875"-1 .000"
( .47- .63)
( .63- .95)
( .95-1 .27)
(1 .27-1 .59)
( .95-1 .27)
(1 .27-1 .59)
(1 .59-1 .90)
(1 .90-2 .22)
(1 .27-1 .59)
(1 .59-1 .90)
(1 .90-2 .22)
(2 .22-2 .54)
Form
Size
F2
F2
F3
F4
Catalog Number
CG404SST
CG406SST
CG408SST
CG410SST
CG608SST
CG610SST
CG612SST
CG614SST
CG810SST
CG812SST
CG814SST
CG816SST
Straight Stainless Steel Male
Note: Kellems® Deluxe Cord Grips are suitable
for use in hazardous locations per Class I
Div. 2, Class II Div. 1 & 2, Class III Div. 1 &
2 of the National Electric Code Sections
501.10(b)(2), 502.10(a)(2), 502.10(b)(2),
503.10(a)(2) and 503.10(b).
* Cable jacket may have to be stripped to
pass through connector body.
Dimensions in Inches (cm)
www.hubbell-wiring.com
T-63
Deluxe Cord GrIps
¾
Grip Diameter Range
Inches
(cm)
Kellems® Wire Management Products
Kellems® Wire Management Products
PG and Metric Threaded Deluxe Cord Grips
Aluminum Fittings, Stainless Steel Mesh, Liquidtight, for Insulated Cables
WARNING! It is important that
you read
all breaking strength, safety
and technical data relating
to this product on pages
T-71 through T-76 .
Straight PG* Male Thread
Cord Diameter Range
Inches
(cm)
Hub Size
PG16
PG21
PG21
.500"- .625"
.500"- .625"
.625"- .750"
.750"- .875"
.625"- .750"
.750"- .875"
.875"-1 .000"
1 .125"-1 .250"
1 .125"-1 .250"
PG29
PG29
PG36
(1 .27-1 .59)
(1 .27-1 .59)
(1 .59-1 .90)
(1 .90-2 .22)
(1 .59-1 .90)
(1 .90-2 .22)
(2 .22-2 .54)
(2 .86-3 .17)
(2 .86-3 .17)
Form Size
Catalog Number
F2
F2
F3
074PG16010
074PG21010
074PG211247
074PG211248
074PG29021
074PG29023
074PG29025
074PG291028**
074PG36028**
F4
F5
F5
Note: * Panzergewinde.
Straight PG Male
Straight Metric Male Thread
Cord Diameter Range
Inches
(cm)
Hub Size
M20
M25
.500"- .625"
.625"- .750"
.750"- .875"
.500"- .625"
.625"- .750"
.750"- .875"
.875"-1 .000"
1 .125"-1 .250"
1 .000"-1 .125"
PG and Metric Threaded Deluxe Cord Grips
M25
M32
M32
Straight Metric Male
Note: Kellems® Deluxe Cord Grips are suitable
for use in hazardous locations per Class I
Div. 2, Class II Div. 1 & 2, Class III Div. 1 &
2 of the National Electric Code Sections
501.10(b)(2), 502.10(a)(2), 502.10(b)(2),
503.10(a)(2) and 503.10(b).
** Cable jacket may have to be stripped to
pass through connector body.
T-64
(1 .27-1 .59)
(1 .59-1 .90)
(1 .90-2 .22)
(1 .27-1 .59)
(1 .59-1 .90)
(1 .90-2 .22)
(2 .24-2 .54)
(2 .86-3 .17)
(2 .54-2 .86)
Form Size
F2
F3
F2
F4
F5
Catalog Number
074M20010
074M251247
074M251248
074M25017
074M32021
074M32023
074M32025
074M321028
074M321250
Specifications
Material
Aluminum
Stainless Steel (Gotcha Rings)
Neoprene (Bushings)
Temperature Range
–30°F to +240°F (–34°C to +115°C) .
–30°F to +240°F (–34°C to +115°C) .
–30°F to +240°F (–34°C to +115°C) .
Hazardous Locations
Suitable for use in hazardous locations per Class I Div . 2,
Class II Div . 1 & 2, Class III Div . 1 & 2 N .E .C .
Reference 501.10(b)(2), 502.10(a)(2), 502.10(b)(2), 503.10(a)(2)
and 503.10(b).
Approvals
Cord Connectors
Deluxe Cord Grips
Wet Locations
UL Listed in accordance with Standard 514B .
UL Control numbers 898D and 899D .
Suitable for use in wet locations when used with a listed
nylon washer between box and fitting .
www.hubbell-wiring.com
Dimensions in Inches (cm)
Dust-Tight Strain Relief Grips
Aluminum Fittings, Galvanized Steel Mesh, for Insulated Cables
WARNING!
It is important that you read
all breaking strength, safety
and technical data relating
to this product on pages
T-71 through T-76 .
Non-Insulated, Wide Range Strain Relief
Thread
Size
Cable
Diameter Range
Inches
(cm)
Mesh Length
@ Nom. Dia.
Inches (cm)
Catalog
Number
½ N .P .T .
½ N .P .T .
½ N .P .T .
¾ N .P .T .
1 N .P .T .
1¼ N .P .T .
PG29*
.24"- .32"
.32"- .43"
.43"- .54"
.54"- .73"
.73"- .97"
.97"-1 .25"
.73"- .97"
3 .25" (8 .25)
3 .75" (9 .52)
4 .75" (12 .06)
6 .5" (16 .51)
7" (17 .78)
9" (22 .86)
7" (17 .78)
073031200
073031201
073031202
073031203
073031204
073031205
073PG291204
( .61- .81)
( .81-1 .09)
(1 .09-1 .37)
(1 .37-1 .85)
(1 .85-2 .46)
(2 .46-3 .17)
(1 .85-2 .46)
Kellems® Wire Management Products
Kellems® Wire Management Products
Note: * Panzergewinde.
Non-Insulated
Insulated, Wide Range Strain Relief with Insulating Bushing
Thread
Size
Cable
Diameter Range
Inches
(cm)
Mesh Length
@ Nom. Dia.
Inches (cm)
½ N .P .S .
½ N .P .S .
½ N .P .S .
¾ N .P .S .
1 N .P .S .
1¼ N .P .S .
1½ N .P .T .
2 N .P .T .
2½ N .P .T .
2½ N .P .T .
.24"- .32" ( .61- .81)
.32"- .43" ( .81-1 .09)
.43"- .54" (1 .09-1 .37)
.54"- .73" (1 .37-1 .85)
.73"- .97" (1 .85-2 .46)
.97"-1 .25" (2 .46-3 .17)
1 .25"-1 .50" (3 .17-3 .81)
1 .50"-1 .70" (3 .81-4 .32)
1 .70"-2 .00" (4 .32-5 .08)
2 .00"-2 .45" (5 .08-6 .22)
3 .25" (8 .25)
3 .75" (9 .52)
4 .75" (12 .06)
6 .5" (16 .51)
7" (17 .78)
9" (22 .86)
11 .75" (29 .84)
13 .25" (33 .65)
13 .5" (34 .29)
13 .75" (34 .92)
Dim. A
In. (cm)
Min. Space
Between
Grips
In. (cm)
Catalog
Number
1" (2 .54)
1" (2 .54)
1" (2 .54)
1" (2 .54)
1 .313" (3 .02)
1 .313" (3 .02)
1 .313" (3 .02)
1 .375" (3 .49)
1 .5" (3 .81)
1 .5" (3 .81)
1 .25" (3 .17)
1 .25" (3 .17)
1 .25" (3 .17)
1 .5" (3 .81)
1 .75" (4 .44)
2 .25" (5 .71)
2 .5" (6 .35)
3 .25" (8 .25)
3 .625" (9 .21)
3 .625" (9 .21)
073031206
073031207
073031208
073031209
073031210
073031211
073031212
073031213
073031214
073031215
Insulated
Dust-Tight Strain Relief Grips
Dimensions in Inches (cm)
www.hubbell-wiring.com
T-65
Kellems® Wire Management Products
Kellems® Wire Management Products
I-Grips
Plastic-Coated, Galvanized Steel Mesh for Insulated Cables
WARNING!
It is important that you read
all breaking strength, safety
and technical data relating
to this product on pages
T-71 through T-76 .
Application
Kellems® I-Grips will fit 2, 3, 4 and 5 wire Hubbell Insulgrip® plugs and
connector bodies . The eye tabs fit under the nylon cord clamp and the
screws slide through the eyelets, securing the grip in place .
These grips are for indoor use only .
Benefits
• Easily attached to Insulgrip plugs and connector bodies.
• Controls cable arc-of-bend.
• Provides heavy-duty strain relief.
• Fits all sizes.
I-Grips
Cable Diameter Range
Inches
(cm)
E
Inches (cm)
M
Inches (cm)
Catalog Number
.32"- .43"
.43"- .56"
.56"- .73"
.73"- .85"
.85"-1 .00"
1 .00"-1 .25"
1 .25" (3 .17)
1 .25" (3 .17)
1 .50" (3 .81)
1 .50" (3 .81)
1 .50" (3 .81)
1 .50" (3 .81)
4" (10 .16)
4 .75" (12 .06)
6" (15 .24)
6 .5" (16 .51)
8" (20 .32)
10" (25 .40)
07310001
07310002
07310003
07310004
07310005
07310006
( .81-1 .09)
(1 .09-1 .42)
(1 .42-1 .85)
(1 .85-2 .16)
(2 .16-2 .54)
(2 .54-3 .17)
I-Grips
Note: E-Eye length.
M-Mesh length at nominal diameter.
Eyelet hole diameter .203" (.52cm).
I-Grips should not be used on Insulgrip devices when “Seal-Tite®” weatherproof covers
are to be installed.
T-66
www.hubbell-wiring.com
Dimensions in Inches (cm)
Thread Adapters for Multi-Pin Connectors
Aluminum
Thread Adapters for Multi-Pin Connectors
Kellems® Thread Adapters are devices formatting
AN-MS connectors and other multi-pin connectors
to Kellems grips with N .P .T . threaded fittings . They
are made of aluminum with internal threads and
replace the connector cord clamp . These adapters
permit the installation of Kellems Grips, to prevent
cable or conduit pull-out and control arc-of-bend .
Applications
Thread adapters allow the installation of Kellems®
Grips on multi-pin connectors at electrical consoles,
mobile equipment, control switches, assembly
equipment and testing machines .
Benefits
• Easy installation.
• Allows the use of Kellems grips.
• Extends connector and cable life.
Thread Adapters for Multi-Pin Connectors
Thread Adapters
AN-MS
Connector
Size**
Deluxe Cord Grips
AN-MS
N.P.T.
Cable Clamp Thread
Thread Catalog
Number*** Size A in. Size B in. Number
Cable Diameter
Range Inches (cm)
Liquidtight
Conduit Grips
(Insulated Throat)
Strain Relief Grips
Catalog
Number
Cable Diameter
Range Inches (cm)
Catalog
Number
Catalog
Number
091041000 .250"- .312" ( .63- .79)
091041001 .312"- .375" ( .79- .95)
091041002 .375"- .437" ( .95-1 .11)
07401001
07401002
07401003
091041003 .187"- .250" ( .47- .63
091041004 .250"- .375" ( .63- .95)
091041006 .375"- .500" ( .95-1 .27)
.500"- .625" (1 .27-1 .59)
07401004 .24"- .32" ( .61- .81)
073031200
—
07401006 .32"- .43" ( .81-1 .09)
073031201 074093512
07401008 .43"- .54" (1 .09-1 .37) 073031202
—
07401010*
⁷⁄₈" x 20"
1" x 20"
¾
1³⁄₁₆" x 18"
091041005 .187"- .250" ( .47- .63)
091041007 .250"- .375" ( .63- .95)
091041008 .375"- .500" ( .95-1 .27)
.500"- .625" (1 .27-1 .59)
.625"- .750" (1 .59-1 .90)
07401011
07401013
07401015
07401017
07401018
3057-12
3057-16
3057-20
3057-24
1³⁄₁₆" x 18"
1⁷⁄₁₆" x 18"
1¾" x 18" 1
2" x 18"
091041009
091041010
091041012
091041015
074011195
07401019
07401021 .73"- .97" (1 .85-2 .46) 073031204 074093514
07401023
07401025
24, 28
32
36
3057-16
3057-20
3057-24
1⁷⁄₁₆" x 18"
1¾" x 18" 1¼
2" x 18"
091041011 .750"- .875" (1 .90-2 .22)
091041013 .875"-1 .000" (2 .22-2 .54)
091041016 1 .000"-1 .125" (2 .54-2 .86)
1 .125"-1 .375" (2 .86-3 .17)
32
36
40
3057-20
3057-24
3057-28
1¾" x 18"
2" x 18"
1½
2¼" x 16"
091041014 .875"-1 .000" (2 .22-2 .54) 07401029
091041017 1 .000"-1 .125" (2 .54-2 .86) 07401030
091041019 1 .125"-1 .250" (2 .86-3 .17) 07401031
1 .250"-1 .375" (3 .17-3 .49) 07401032
½" x 28"
⁵⁄₈" x 24"
¾" x 20"
³⁄₈
14, 14S
16, 16S
18
3057-6
3057-8
3057-10
¾" x 20"
⁷⁄₈" x 20"
1" x 20"
½
16, 16S
18
20, 22
3057-8
3057-10
3057-12
20, 22
24, 28
32
36
.375"- .500" ( .95-1 .27)
.500"- .625" (1 .27-1 .59)
.625"- .750" (1 .59-1 .90)
.750"- .875" (1 .90-2 .22)
.875"-1 .000" (2 .22-2 .54)
.54"- .74" (1 .37-1 .85) 073031203 074093513
074011251
07401026
07401027 .97"-1 .25" (2 .46-3 .17) 073031205 074093515
07401028
—
074093516
Note: * Cable jacket may have to be stripped to pass through connector body.
** Number stamped on connector shell.
*** Number stamped on clamp shell.
Example
Thread Adapter
091041006
Dimensions in Inches (cm)
www.hubbell-wiring.com
T-67
Thread Adapters for Multi-Pin Connectors
8S, 10S
3057-3
10SL, 12, 12S 3057-4
14, 14S
3057-6
Kellems® Wire Management Products
Kellems® Wire Management Products
Kellems® Wire Management Products
Kellems® Wire Management Products
Strain Relief for Liquidtight Conduit
Steel Fitting, Stainless Steel Mesh for Liquidtight Metal Conduit
and PolyTuff I Non-Metallic Conduit
WARNING!
It is important that you read
all breaking strength, safety
and technical data relating
to this product on pages
T-77, T-79 and T-80 .
Benefits
• Helps prevent conduit pull-out and damage at the fitting.
• Reduces equipment downtime.
Straight With Male Fitting
Conduit
Trade Size
Inches
Straight with Male Fitting
N.P.T.
Fitting Size
Inches
Mesh Length
Inches (cm)
Catalog Number
(Insulated)
Catalog Number
(Non-insulated)
³⁄₈
½
3"
(7 .62)
074093511
074093401
½
½
3 .5"
(8 .89)
074093512
074093402
¾
¾
4"
(10 .16)
074093513
074093403
1
1
5"
(12 .70)
074093514
074093404
1¼
1¼
6"
(15 .24)
074093515
074093405
1½
1½
6 .75" (17 .14)
074093516
074093406
2
2
8"
(20 .32)
074093518
074093408
2½
2½
9 .75" (24 .76)
074093520
074093410
074093412
3
3
11"
(27 .94)
074093522
4
4
14"
(35 .56)
074093526
—
90° Angle With Male Fitting
Strain Relief for Liquidtight Conduit
Conduit
Trade Size
Inches
90° Angle with Male Fitting
T-68
N.P.T.
Fitting Size
Inches
Mesh Length
Inches (cm)
Catalog Number
(Insulated)
Catalog Number
(Non-insulated)
³⁄₈
½
3"
(7 .62)
074093541
074093421
½
½
3 .5"
(8 .89)
074093542
074093422
¾
¾
4"
(10 .16)
074093543
074093423
1
1
5"
(12 .70)
074093544
074093424
1¼
1¼
6"
(15 .24)
074093545
074093425
1½
1½
6 .75" (17 .14)
074093546
074093426
2
2
8"
(20 .32)
074093548
074093428
2½
2½
9 .75" (24 .76)
074093550
—
3
3
11"
074093552
—
(27 .94)
Note: For use with Liquidtight Metal conduit and PolyTuff I Non-Metallic conduit.
www.hubbell-wiring.com
Dimensions in Inches (cm)
Strain Relief for Liquidtight Conduit
Steel Fitting, Stainless Steel Mesh for Liquidtight Metal Conduit
and PolyTuff I Non-Metallic Conduit
Straight With Chase Fitting
Conduit
Trade Size
Inches
N.P.T.
Fitting Size
Inches
Mesh Length
Inches (cm)
Catalog Number
½
½
3 .5"
(8 .89)
07406079
¾
¾
4"
(10 .16)
07406080
1
1
5"
(12 .70)
07406081
1¼
1¼
6"
(15 .24)
07406082
1½
1½
6 .75" (17 .14)
07406083
WARNING!
It is important that you read
all breaking strength, safety
and technical data relating
to this product on pages
T-77, T-79 and T-80 .
Kellems® Wire Management Products
Kellems® Wire Management Products
Straight with Chase Connector
45° Angle With Male Fitting
Conduit
Trade Size
Inches
N.P.T.
Fitting Size
Inches
Mesh Length
Inches (cm)
Catalog Number
(Insulated)
Catalog Number
(Non-insulated)
³⁄₈
½
3"
(7 .62)
074093561
074093441
½
½
3 .5"
(8 .89)
074093562
074093442
¾
¾
4"
(10 .16)
074093563
074093443
1
1
5"
(12 .70)
074093564
074093444
1¼
1¼
6"
(15 .24)
074093565
074093445
1½
1½
6 .75" (17 .14)
074093566
074093446
2
2
8"
074093568
074093448
(20 .32)
45° Angle with Male Fitting
Dimensions in Inches (cm)
www.hubbell-wiring.com
T-69
Strain Relief for Liquidtight Conduit
Note: For use with Liquidtight Metal conduit and PolyTuff I Non-Metallic conduit.
Kellems® Wire Management Products
Kellems® Wire Management Products
Strain Relief for Liquidtight Conduit
Steel Fitting, Stainless Steel Mesh for UL Type A Liquidtight Conduit
WARNING!
It is important that you read
all breaking strength, safety
and technical data relating
to this product on pages
T-78 through T-80 .
Straight Male Hubbell Fitting
Conduit
Trade Size
Inches
N.P.T.
Fitting Size
Inches
Mesh Length
Inches (cm)
Catalog Number
³⁄₈
½
3 .75" (9 .52)
H038CNK
½
½
4 .5" (11 .43)
H050CNK
¾
¾
6 .25" (15 .87)
H075CNK
1
1
7 .5" (19 .05)
H100CNK
1¼
1¼
9"
(22 .86)
H125CNK
1½
1½
13 .5" (34 .29)
H150CNK
2
2
14 .5" (36 .83)
H200CNK
Straight Male with Fitting
90° Male Hubbell Fitting
N.P.T.
Fitting Size
Inches
Mesh Length
Inches (cm)
Catalog Number
³⁄₈
½
3 .75" (9 .52)
H0389CNK
½
½
4 .5" (11 .43)
H0509CNK
¾
¾
6 .25" (15 .87)
H0759CNK
1
1
7 .5" (19 .05)
H1009CNK
1¼
1¼
9"
(22 .86)
H1259CNK
1½
1½
13 .5" (34 .29)
H1509CNK
2
2
14 .5" (36 .83)
H2009CNK
Strain Relief for Liquidtight Conduit
90° Angle
Conduit
Trade Size
Inches
T-70
www.hubbell-wiring.com
Dimensions in Inches (cm)
Technical Information
Strain Relief Grips
Kellems Strain Relief Grips are designed to prevent tension
from being transmitted to joints and terminals on electrical
cord, cable and conduit . In most applications, a Kellems
grip for strain relief is stronger than the cable itself and
gives much greater security than the use of a fitting alone .
Kellems Grips for strain relief help make electrical systems
safer, and save money by minimizing downtime from
costly electrical failure due to cable pull-out . Kellems Grips
also aid in compliance with the National Electric Code’s
terminal tension protection requirements .
Select the Correct Grip for Strain Relief
Kellems Grips for strain relief are designed to fit on
electrical cord, cable or flexible conduit .
Step 1 Refer to the chart below to determine the
grip style best suited for your application .
Step 2 Determine your cable outside diameter or
conduit size .
Step 3 Locate environment—indoors or outdoors .
Step 4 Decide if a liquidtight seal is required .
Step 5 Select N .P .T . size and fitting style .
Kellems® Wire Management Products
Kellems® Wire Management Products
Strain Relief System Selection Chart
Type Fitting or
Attachment
Page
Number
Aluminum fittings,
stainless steel mesh,
neoprene oil-andwatertight bushing .
Double-single weave .
.187"-3 .250"
( .47-8 .25)
N .P .T ., PG, and metric
aluminum, male straight,
45° male, 90° male,
female straight .
Thread sizes ³⁄₈"-3" .
T-60, T-61,
T-64
Outdoors or indoors where
subjected to moisture or
splash . Examples are
marine and food
processing equipment .
Nylon fitting, stainless
steel mesh, double-single
weave, neoprene oil-andwatertight bushing .
.187"-1 .125"
( .47-2 .86)
N .P .T . nylon,
male straight,
90° male . Thread
sizes ½"-1" .
T-62
Deluxe Cord
Nylon Fitting/
Non-metallic
Grip
Indoor or outdoors .
Provides liquidtight seal,
where exposed to moisture .
Excellent for oil refining
and chemical processing .
Non-metallic grip is
corrosion resistant,
nonconductive and
provides superior gripping and flexing benefits .
Neoprene liquidtight
bushing . Nylon fitting .
.187"-1 .000"
( .47-2 .54)
N .P .T . nylon, straight male, T-63
thread sizes ³⁄₈"-1" 90° male,
thread sizes ½"-1" .
Deluxe Cord
Stainless
Steel Fitting
And Grip
Indoor or outdoor use where
exposed to moisture . Very
strong for heavy abuse areas
such as drilling platforms,
steel mills and mines .
Stainless steel fitting
and grip for strength .
Neoprene liquidtight
bushing . Double/single
weave grip .
.187"-1 .000"
( .47-2 .54)
Straight male
Only with N .P .T .
Thread sizes ½"-1" .
T-63
Dust-Tight
Strain Relief
Indoor use only for wiring
of electrical enclosures,
machine tools, portable
power tools, bus drop
cable systems .
Neoprene gasket–seals
.240"-2 .450"
out chips, dirt, dust .
( .61-6 .22)
One piece design with
galvanized steel mesh .
Insulating bushing available .
Zinc-plated steel locknut .
Straight male N .P .S .
or N .P .T .
T-65
Liquidtight
Flexible
Conduit Grip
(Metal and
Non-Metallic)
Wiring of machine tools,
electrical enclosures, motors
and systems where metallic
liquidtight flexible conduit
is subjected to vibration,
flexure, motion or strain .
Stainless steel mesh,
liquidtight fittings .
Sealing “O" rings
(optional) . Choice of
fittings .
.375"-4 .000"
trade sizes
N .P .T . ½"-4",
Hubbell fittings,
Male straight,
45° male, 90° male,
female straight .
T-68, T-69
Liquidtight
Flexible
Conduit Grip
(UL Type A)
Wiring or machine tools,
electrical enclosures,
motors and systems
where conduit is subject
to vibration and strain .
Stainless steel mesh,
liquidtight fittings with
“O" ring and locknut .
.375"-2 .008"
trade size male
N .P .T . steel,
Hubbell fittings,
straight male, 90°
Thread sizes ½"-2" .
T-70
Application
Features
Deluxe Cord
Aluminum
Fitting/
Stainless
Steel Grip
Outdoors or indoors where
subjected to moisture or
splash . Examples are crane
and hoist pendant drop
stations, hand tools, pumps
and processing equipment .
Deluxe Cord
Nylon Fitting/
Stainless
Steel Grip
Dimensions in Inches (cm)
www.hubbell-wiring.com
T-71
Technical Information
Cord or Conduit
Range Inches (cm)
Grip Type
Kellems® Wire Management Products
Kellems® Wire Management Products
Technical Information
Strain Relief Grips
Wire Mesh Grip Materials
Material
Galvanized steel wire
Stainless steel wire (302/304)
Non-metallic strand
Features
• High strength
• Not subject to continuous outside environment
• High strength
• Corrosion resistant
• Slightly magnetic
Product Group
• Strain relief grips
• I-Grips
• Deluxe cord grips
• Liquidtight, flexible, metal conduit grips
• UL type A conduit grips
• Superior flex life
• Non-conductive
• Corrosion resistant
• Moderate strength
• Non-metallic deluxe cord grips
Operating Temperatures
Material
Temperature Range
Aluminum
–40°F to +300°F (–40°C to +149°C) .
Aluminum Deluxe Cord Grips
–30°F to +240°F (–34°C to +115°C) .
Non-Metallic Deluxe Cord Grips
–30°F to +225°F (–34°C to +107°C) .
Nylon
–40°F to +225°F (–40°C to +107°C) .
Nylon Fitting with Stainless Steel Mesh
–40°F to +225°F (–40°C to +107°C) .
Stainless Steel
–60°F to +1000°F (–51°C to +537°C) .
Stainless Steel Deluxe Cord Grips
–30°F to +240°F (–34°C to +115°C) .
Neoprene (Bushings)
–30°F to +240°F (–34°C to +115°C) .
Hazardous Locations
Product Categories
The product categories listed to the right are suitable
for use in hazardous locations per Class I Div . 2,
Class II Div . 1 & 2, Class III Div . 1 & 2 .
Deluxe cord grip, aluminum fitting;
Deluxe cord grip, nylon fitting;
Deluxe cord grip, non-metallic;
Sealtite conduit grips;
Dustight strain relief grips .
Flammability
Non-metallic deluxe cord grips will not support combustion . Listed below are the ratings .
Component
Rating
Mesh grip
UL 94HB .
Fitting
UL 94V-2 .
Approvals
Technical Information
UL Listing and CSA Certification are indicated on appropriate product catalog pages .
Agency
UL Control Number
Underwriters Laboratories Inc .
898D and 899D .
Wet Locations
Product Categories
The products noted to the right are suitable
for use in wet locations when a listed sealing
ring is used between box and fitting .
T-72
Deluxe cord grip, aluminum fitting;
Deluxe sealing ring cord grip;
Deluxe cord grip, non-metallic;
Sealtite conduit grips;
Hubbell non-metallic conduit grips;
Cord connectors;
Hubbell Juniors;
PolyTuff® connectors;
Hubbell sealtite conduit connectors .
www.hubbell-wiring.com
Dimensions in Inches (cm)
Technical Information
Strain Relief Grips
Form Size Definition
The term “Form Size” refers to the physical mass or overall dimensions of a cord connector . Form 1 is the
smallest size, Form 8 is the largest size .
Knockout Holes
N.P.T.
Hub Size
Inches
Knockout Hole Recommended
Min. to Max. Inches (cm)
¼
.540"
to .570"
(1 .37-1 .45)
³⁄₈
.671"
to .701"
(1 .70-1 .78)
½
.859"
to .906"
(2 .18-2 .30)
¾
1 .094" to 1 .141" (2 .78-2 .90)
1
1 .359" to 1 .406" (3 .45-3 .57)
1¼
1 .719" to 1 .766" (4 .37-4 .49)
1½
1 .969" to 2 .016" (5 .00-5 .12)
2
2 .453" to 2 .500" (6 .23-6 .35)
2½
2 .953" to 3 .000" (7 .50-7 .62)
3
3 .578" to 3 .625" (9 .09-9 .21)
Kellems® Wire Management Products
Kellems® Wire Management Products
Product Data
Deluxe Cord Grips, Liquidtight for Insulated Cables
Deluxe Cord Grips helps to alleviate pull tension on terminals, control cable arc-of-bend, prevent cord pullout, and provide a liquidtight seal . They are offered with either aluminum, stainless steel or nylon fittings in
a variety of configurations and N .P .T . thread sizes . Additionally, a completely non-metallic product is offered
on page T-63 .
Application
Deluxe Cord Grips are used indoors or outdoors to help prevent cord pull-out, and where cables are
subjected to moisture, splash or submersion . Specific uses are: wiring enclosures, pendant stations,
hand tools, construction, processing and material handling equipment, pumps, motors and machine tools .
Benefits
Dimensions in Inches (cm)
www.hubbell-wiring.com
Technical Information
• Helps to prevent cable pull-out.
• Controls cable arc-of-bend.
• Provides a liquidtight seal.
• Corrosion resistant stainless steel mesh with aluminum collar.
T-73
Kellems® Wire Management Products
Kellems® Wire Management Products
Technical Information
Strain Relief Grips
Deluxe Cord Grips Fitting Dimensions
Straight Hubbell Connectors
F
N.P.T.
(Inches)
Aluminum, Inches (cm)
A
B
C
Form
D
E
Throat
Dia.
A/C*
A/F*
Nylon, Inches (cm)
A
B
C
Dia.
Ref.
.88"
(2 .24)
.90"
(2 .29)
.46" .44"
(1 .17) (1 .12)
.99" .88"
(2 .51) (2 .24)
1 .00" 1 .10" .43" .45" 1 .00" .93"
(2 .54) (2 .79) (1 .09) (1 .14) (2 .54) (2 .36)
1 .01" .88" .90" .46" .45" .87" .75"
(2 .57) (2 .24) (2 .29) (1 .17) (1 .14) (2 .21) (1 .90)
½-14
1
.88"
(2 .24)
.90"
(2 .29)
.46" .44"
(1 .17) (1 .12)
1 .00" .88"
(2 .54) (2 .24)
1 .00" 1 .10" .46" .45" 1 .00" .93"
(2 .54) (2 .79) (1 .17) (1 .14) (2 .54) (2 .36)
—
½-14
2
1 .13"
(2 .87)
1 .10"
(2 .79)
.55" .64"
(1 .40) (1 .63)
1 .11" 1 .00"
(2 .82) (2 .54)
1 .32" 1 .50" .53" .58" 1 .25" 1 .12"
(3 .35) (3 .81) (1 .35) (1 .47) (3 .17) (2 .84)
1 .30" 1 .13" 1 .10" .54" .63" 1 .16" 1 .00"
(3 .30) (2 .87) (2 .79) (1 .37) (1 .60) (2 .95) (2 .54)
½-14
3
1 .38"
(3 .51)
1 .50"
(3 .81)
.55" .64"
(1 .40) (1 .63)
1 .40" 1 .25"
(3 .56) (3 .17)
—
—
—
—
—
—
—
—
—
—
—
—
—
¾-14
2
1 .13"
(2 .87)
1 .10"
(2 .79)
.55" .64"
(1 .40) (1 .63)
1 .29" 1 .13"
(3 .28) (2 .87)
—
—
—
—
—
—
—
—
—
—
—
—
—
¾-14
3
1 .38"
(3 .51)
1 .50"
(3 .81)
.55" .82"
(1 .40) (2 .08)
1 .40" 1 .25"
(3 .56) (3 .17)
1 .56" 1 .60" .55" .77" 1 .44" 1 .31"
(3 .96) (4 .06) (1 .40) (1 .96) (3 .66) (3 .33)
1-11½
3
—
—
—
—
1-11½
4
1 .75"
(4 .44)
1 .60"
(4 .06)
.71" 1 .02"
(1 .80) (2 .59)
1 .81" 1 .62"
(4 .60) (4 .11)
1 .88" 1 .75" .70" 1 .01" 1 .84" 1 .63"
(4 .78) (4 .44) (1 .78) (2 .57) (4 .67) (4 .14)
2 .02" 1 .75" 1 .40" .70" 1 .03" 1 .88" 1 .63"
(5 .13) (4 .44) (3 .56) (1 .78) (2 .62) (4 .78) (4 .14)
1-11½
5
2 .31"
(5 .87)
1 .70"
(4 .32)
.66" 1 .01"
(1 .68) (2 .57)
2 .28" 2 .00"
(5 .79) (5 .08)
—
—
—
—
—
—
—
—
—
—
—
—
—
1¼-11½
5
2 .31"
(5 .87)
1 .70"
(4 .32)
.74" 1 .26"
(1 .88) (3 .20)
2 .28" 2 .12"
(5 .79) (5 .38)
—
—
—
—
—
—
—
—
—
—
—
—
—
1½-11
5
2 .31"
(5 .87)
1 .70"
(4 .32)
.74" 1 .38"
(1 .88) (3 .51)
2 .28" 2 .12"
(5 .79) (5 .38)
—
—
—
—
—
—
—
—
—
—
—
—
—
1½-11½
6
3 .00"
(7 .62)
2 .20"
(5 .59)
.75" 1 .50"
(1 .90) (3 .81)
2 .97" 2 .75"
(7 .54) (6 .98)
—
—
—
—
—
—
—
—
—
—
—
—
—
2-11½
6
3 .00"
(7 .62)
2 .20"
(5 .59)
.80" 1 .92"
(2 .03) (4 .88)
3 .24" 3 .00"
(8 .24) (7 .62)
—
—
—
—
—
—
—
—
—
—
—
—
—
2-11½
7
3 .85"
(9 .78)
2 .70"
(6 .86)
.88" 1 .94"
(2 .24) (4 .93)
4 .05" 3 .75"
(10 .29) (9 .52)
—
—
—
—
—
—
—
—
—
—
—
—
—
2½-8
7
3 .85"
(9 .78)
2 .70"
(6 .86)
1 .30" 2 .32"
(3 .30) (5 .89)
4 .34" 4 .02" —
(11 .02) (10 .21)
—
—
—
—
—
—
—
—
—
—
—
—
2½-8
8
4 .75" 2 .70"
(12 .06) (6 .86)
1 .25" 2 .38"
(3 .17) (6 .05)
4 .86" 4 .50" —
(12 .34) (11 .43)
—
—
—
—
—
—
—
—
—
—
—
—
3-8
7
3 .85"
(9 .78)
2 .70"
(6 .86)
1 .30" 2 .54"
(3 .30) (6 .45)
4 .34" 4 .01" —
(11 .02) (10 .21)
—
—
—
—
—
—
—
—
—
—
—
—
3-8
8
4 .50" 2 .70"
(11 .43) (6 .86)
1 .38" 3 .00"
(3 .51) (7 .62)
4 .86" 4 .50" —
(12 .34) (11 .43)
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
A/F*
—
A/C*
A/F
D
E
Throat
Dia.
A/C* A/F*
1
—
Ref.
Stainless Steel, Inches (cm)
A
B
C
³⁄₈-18
—
Dia.
D
E
Throat
Dia.
A/C*
—
—
—
—
—
—
1 .59" 1 .38" 1 .30" .56" .81" 1 .44" 1 .25"
(4 .04) (3 .51) (3 .30) (1 .42) (2 .06) (3 .66) (3 .17)
—
—
—
—
—
—
—
Technical Information
Note: *A/C— Across Corners; A/F—Across Flats.
A
(Overall)
B Ref.
E
F
C
D
T-74
Dimensions shown are approximate and
are subject to change without notice.
www.hubbell-wiring.com
Dimensions in Inches (cm)
Kellems® Wire Management Products
Kellems® Wire Management Products
Technical Information
Strain Relief Grips
Deluxe Cord Grips Fitting Dimensions
45° Hubbell Connectors
Aluminum, Inches (cm)
F
N.P.T.
(Inches)
Form
½-14
2
¾-14
3
1-11½
4
1¼-11½
5
1½-11½
5
A
B
Ref
Ref
2 .00"
(5 .08)
2 .30"
(5 .84)
2 .60"
(6 .60)
3 .90"
(9 .91)
3 .90"
(9 .91)
1 .90"
(4 .83)
2 .50"
(6 .53)
2 .80"
(7 .11)
3 .90"
(9 .91)
3 .90"
(9 .91)
C
D
Throat
Dia.
E
Across
Comers
Across
Flats
.550"
(1 .40)
.560"
(1 .42)
.700"
(1 .78)
.740"
(1 .88)
.740"
(1 .88)
.560"
(1 .42)
.750"
(1 .90)
1 .000"
(2 .54)
1 .250"
(3 .17)
1 .500"
(3 .81)
1 .270"
(3 .23)
1 .480"
(3 .76)
1 .690"
(4 .29)
2 .45"
(6 .22)
2 .45"
(6 .22)
1 .110"
(2 .79)
1 .281"
(3 .25)
1 .500"
(3 .81)
2 .125"
(5 .40)
2 .125"
(5 .40)
C
D
Throat
Dia.
E
A/C*
A/F*
Dia.
.460"
(1 .17)
.500"
(1 .27)
.560"
(1 .42)
.700"
(1 .78)
.730"
(1 .85)
.750"
(1 .92)
.800"
(2 .03)
.440"
(1 .12)
.546"
(1 .39)
.765"
(1 .94)
1 .000"
(2 .54)
1 .260"
(3 .20)
1 .500"
(3 .81)
1 .920"
(4 .88)
1 .15"
(2 .92)
1 .30"
(3 .30)
1 .49"
(3 .78)
1 .70"
(4 .32)
2 .47"
(6 .27)
2 .47"
(6 .27)
2 .98"
(7 .57)
1 .10"
(2 .79)
1 .13"
(2 .87)
1 .31"
(3 .33)
1 .50"
(3 .81)
2 .15"
(5 .46)
2 .15"
(5 .46)
2 .78"
(7 .06)
.875"
(2 .22)
1 .125"
(2 .86)
1 .375"
(3 .49)
1 .750"
(4 .44)
2 .310"
(5 .87)
2 .310"
(5 .87)
3 .000"
(7 .62)
B Ref.
G
G
Dia.
1 .125"
(2 .86)
1 .375"
(3 .49)
1 .750"
(4 .44)
2 .310"
(5 .87)
2 .310"
(5 .87)
A
Ref.
E
C
F
D
90° Hubbell Connectors
Aluminum, Inches (cm)
F
N.P.T.
(Inches)
A
Form
³⁄₈-18
1
½-14
2
¾-14
3
1-11½
4
1¼-11½
5
1½-11½
5
2-11½
6
B
Ref
1 .27"
(3 .23)
1 .56"
(3 .96)
1 .79"
(4 .55)
2 .08"
(5 .28)
3 .18"
(8 .08)
3 .18"
(8 .08)
3 .51"
(8 .92)
2 .00"
(5 .08)
2 .30"
(5 .84)
2 .80"
(7 .11)
3 .20"
(8 .13)
4 .30"
(10 .92)
4 .30"
(10 .92)
5 .50"
(13 .97)
Nylon, Inches (cm)
G
A
B
C
Dia.
D
Throat
A/C*
Ref
—
—
1 .41"
(3 .58)
1 .65"
(4 .19)
1 .99"
(5 .05)
—
E
G
A/F Dia.
—
—
—
—
—
2 .50"
(6 .35)
2 .81"
(7 .14)
3 .30"
(8 .38)
—
.550"
(1 .40)
.560"
(1 .42)
.700"
(1 .78)
—
.575"
(1 .46)
.765"
(1 .94)
1 .010"
(2 .57)
—
1 .23"
(3 .12)
1 .42"
(3 .61)
1 .82"
(4 .62)
—
1 .12"
(2 .82)
1 .29"
(3 .28)
1 .60"
(4 .06)
—
1 .315"
(3 .34)
1 .560"
(3 .96)
1 .875"
(4 .76)
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Note: *A/C - Across Corners; A/F - Across Flats.
B Ref.
A
E
C
F
D
Dimensions shown are approximate and
are subject to change without notice.
Dimensions in Inches (cm)
www.hubbell-wiring.com
T-75
Technical Information
G
Kellems® Wire Management Products
Kellems® Wire Management Products
Technical Information
Strain Relief Grips
Deluxe Cord Grips Fitting Dimensions
Female Hubbell Connectors
A
(Overall)
Aluminum Inches (cm)
F
N.P.T.
Form
³⁄₈-18
1
½-14
2
¾-14
2
1-11½
4
1¼-11½
5
1½-11½
5
B Ref.
E
D
F
C (N.P.T. Thread Depth)
A
B
Dia.
Ref
.88"
(2 .24)
1 .13"
(2 .87)
1 .13"
(2 .87)
1 .75"
(4 .44)
2 .31"
(5 .87)
2 .31"
(5 .87)
1 .40"
(3 .56)
1 .80"
(4 .57)
2 .10"
(5 .33)
2 .30"
(5 .84)
2 .80"
(7 .11)
2 .80"
(7 .11)
C
D
Throat
Dia.
Across
Corners
.560"
(1 .42)
.560"
(1 .42)
.750"
(1 .90)
.880"
(2 .24)
.950"
(2 .41)
.950"
(2 .41)
.44"
(1 .12)
.63"
(1 .60)
.63"
(1 .60)
1 .10"
(2 .79)
1 .43"
(3 .63)
1 .43"
(3 .63)
.94"
(2 .39)
1 .15"
(2 .92)
1 .44"
(3 .66)
1 .88"
(4 .78)
2 .64"
(6 .71)
2 .64"
(6 .71)
E
Across
Flats
.81"
(2 .06)
1 .00"
(2 .54)
1 .25"
(3 .17)
1 .63"
(4 .14)
2 .29"
(5 .82)
2 .29"
(5 .82)
Product Data
Dust-Tight Strain Relief Grips for Insulated Cables
Kellems Strain Relief Grips connect flexible cord or bus drop cable to electrical
enclosures . For indoor use only, they are available with either insulated or noninsulated aluminum fittings, and feature single weave, galvanized steel mesh grips
with patented wide range mesh construction . They come with a locknut and a
neoprene gasket that provides a dust tight seal .
Application
Used to connect electrical cable to power boxes, cabinets, panel boards, power
centers, machine tools and with bus drop systems .
Benefits
• Helps prevent cord or cable pull-out.
• Provides a dust tight seal.
• Easy installation.
• Patented mesh construction.
• One piece design.
I-Grips for Insulated Cables
Kellems I-Grips are made of high strength, plastic coated galvanized steel strand .
They are offered in six sizes to fit all cable diameters used with Hubbell Insulgrip®
Kellems l-Grips will control cable arc-of-bend and reduce high pull tensions from
being transmitted to the wiring terminals .
Application
Technical Information
Kellems I-Grips will fit 2, 3, 4 and 5 wire Hubbell Insulgrip plugs and connector
bodies . The eye tabs fit under the nylon cord clamp and the screws slide through the
eyelets, securing the grip in place .
I-Grips can be used on any Insulgrip cord set which requires cable, arc-of-bend
control or heavy duty strain relief . Cord sets used at in-door construction sites or for
plant maintenance jobs are examples .
These grips are for indoor use only .
Benefits
• Easily attached to Insulgrip plugs
and connector bodies.
• Fits all sizes.
• Provides heavy duty strain relief.
• Controls cable arc-of-bend.
Note: I-Grips should not be used on Insulgrip devices when “Seal-Tite®” weatherproof covers are to be installed.
Dimensions shown are approximate and
are subject to change without notice.
T-76
www.hubbell-wiring.com
Dimensions in Inches (cm)
Technical Information
Strain Relief for Liquidtight Conduit
Strain Relief Grips for Liquidtight Flexible Metal and PolyTuff I Non-Metallic Conduit
Kellems Liquidtight, Flexible Metal Conduit Grips are offered with high quality Hubbell plated steel fittings in a wide
variety of N .P .T . sizes and configurations, either insulated or non-insulated . The addition of a stainless steel mesh to
these fittings makes them stronger than the conduit itself . Kellems Conduit Grips helps prevent conduit pull-out from
the connecting fitting that is subject to stress, pull tension, vibration, motion or strain . They promote safe electrical
systems and reduce equipment downtime .
Application
Kellems Conduit Grips are used in the wiring of machine tools, motors, molding equipment, transformers, weaving
and paper machines, fans, lighting, bakeries, breweries, food processing, chemical plants, dairies, mines and any
application that requires Liquidtight Conduit .
Benefits
• Helps prevent conduit pull-out and damage at the fitting.
Kellems® Wire Management Products
Kellems® Wire Management Products
• Reduces equipment downtime.
• Liquidtight fittings.
• Easily installed.
• Stainless steel grip resists corrosion.
Kellems Conduit Grips are suitable for use in hazardous locations per Class I Div . 2, Class II Div . 1 & 2,
Class III Div . 1 & 2 of the National Electric Code .
Connectors with insulated throats protect
insulation on wires during wire pulling .
Yellow color easily seen by inspectors .
2½" - 4" sizes include insulating bushing
instead of fixed insulator
Nylon gland ring is split for ease of installation
and greater compression . Reversible design
cannot be installed facing the wrong way .
Nylon is impervious to liquids, resistant to
temperature extremes and resists abrasion
Steel grounding ferrule easily
threaded by hand . Fits convolutions
to conduit . Eliminates pullouts and
insures continuity of ground;
distortion free to remain reusable
Optional Sealing Washer gives
better liquidtight protection
around knockout of sheet metal
box . Neoprene gasket seals out
liquids and steel retaining ring
protects gasket from distortion;
order separately
Body is virtually unbreakable .
Straight connectors through 1" are
screw machine steel; other sizes
malleable iron . Threads at left are
tapered to insure liquidtight seal in
threaded hub . Liquidtight conduit
cutaway view shows flexible steel
core under plastic jacket
Dimensions in Inches (cm)
www.hubbell-wiring.com
Hexagonal compression
nut is screw machined steel
through 1" and malleable
iron on larger sizes
Wire mesh grip
prevents pullout
Liquidtight conduit cutaway
view shows flexible steel core
under plastic jacket
T-77
Technical Information
Hardened Steel Locknut
has tangs that dig into box
for excellent continuity of
ground; locknut will not slip
or spin
Kellems® Wire Management Products
Kellems® Wire Management Products
Technical Information
Strain Relief for Liquidtight Conduit
Strain Relief for UL Type A, Flexible, Liquidtight Conduit
Kellems Grips for UL Type A, non-metallic, flexible, liquidtight conduit are available in straight and 90° male and feature
a high quality Hubbell plated steel or malleable iron fitting, complete with a sealing O-ring, lock nut and stainless steel
mesh . These grips increase the retention of the conduit in the fitting, control its arc-of-bend and provide a liquidtight seal .
Application
These grips are used on UL Type A non-metallic conduit connections at limit switches, motor boxes, panel boards,
control stations and on all types of machinery and machine tools .
Benefits
•
•
•
•
Provides a liquidtight seal.
Helps prevent conduit pull-out.
Reduces conduit cutting, kinking, fraying and splitting at the fitting.
Easily installed.
Steel Locknut has tangs that dig
into box for excellent continuity of
ground; locknut will not slip or spin
Neoprene O-ring is factory
assembled into the body
to seal out liquids
Body is virtually unbreakable . Straight connectors through
1" are screw machine steel; other sizes are malleable iron .
Threads are tapered to insure liquidtight seal when used in
threaded hub; octagonal shape inside holds the ferrule to
prevent conduit from twisting during installation
Technical Information
Wire mesh grip
prevents pullout
Insulated throat protects
insulation on wires during
pulling; yellow color easily
seen by inspectors
Yellow nylon ferrule fits inside nonmetallic conduit to hold the shape;
barb in designed to assure liquidtight
seal even with non-square cut;
ferrule is keyed to fit into body to
prevent conduit twisting
Hexagonal compression nut is machine
steel through 1" malleable iron on larger
sizes; tapered interior compresses
sleeve over conduit sealing out liquids
and preventing pullout
Yellow nylon sleeve installs over
conduit; six slits in sleeve permit
tight compression onto conduit
as compression nut is tightened
T-78
www.hubbell-wiring.com
Dimensions in Inches (cm)
Technical Information
Strain Relief for Liquidtight Conduit
Liquidtight Conduit Grip Fitting Dimensions-Inches
45° Angle with Male Fitting
E
A/C A/F
Dimensions
D
Throat
Dia.
C
A
Ref.
Trade H
Size
B
Ref.
J
H
L
N
A/C A/F
K
M
Throat
Dia.
F
D
E
G
O
Throat
Dia.
Straight with Male Fitting
M
Throat
N
Dia.
A/C* A/F*
Catalog
Number
1 .19" 1 .28" .59" 1 .20" 1 .06" .60"
1 .16" 1 .02" 074093441
½
1 .19" 1 .28" .59" 1 .34" 1 .19" .61"
1 .21" 1 .06" 074093442
¾
1 .19" 1 .43" .59" 1 .55" 1 .45" .84"
1 .50" 1 .32" 074093443
1
1 .38" 1 .53" .66" 1 .95" 1 .69" 1 .05" 1 .82" 1 .59" 074093444
1¼
1 .42" 1 .69" .63" 2 .39" 2 .06" 1 .37" 2 .32" 2 .03" 074093445
1½
1 .66" 2 .00" .66" 2 .72" 2 .38" 1 .60" 2 .62" 2 .29" 074093446
2
1 .69" 2 .25" .66" 3 .08" 2 .88" 2 .05" 3 .21" 2 .80" 074093448
45° Angle with Male Fitting with Insulated Throat
J
Ref.
K
L
A/C* A/F*
M
Throat
N
Dia.
A/C* A/F*
Catalog
Number
³⁄₈
1 .25" 1 .28" .66" 1 .20" 1 .06" .57"
1 .16" 1 .02" 074093561
½
1 .25" 1 .28" .66" 1 .34" 1 .19" .57"
1 .21" 1 .06" 074093562
¾
1 .25" 1 .44" .66" 1 .55" 1 .45" .78"
1 .50" 1 .32" 074093563
1
1 .44" 1 .53" .72" 1 .95" 1 .69" .98"
1 .82" 1 .59" 074093564
1¼
1 .48" 1 .69" .69" 2 .39" 2 .06" 1 .29" 2 .32" 2 .03" 074093565
1½
1 .72" 2 .00" .72" 2 .72" 2 .38" 1 .53" 2 .62" 2 .29" 074093566
2
1 .75" 2 .25" .72" 3 .08" 2 .87" 1 .95" 3 .21" 2 .80" 074093568
90° Angle with Male Fitting
Dimensions
C
A/C* A/F*
L
A/C* A/F*
³⁄₈
Trade H
Size
B
K
Dimensions
P
A/C A/F
Trade A
Size Ref.
J
Ref.
D
Throat
E
Dia. A/C* A/F*
Catalog
Number
Dimensions
³⁄₈
1 .43" .59"
1 .20" 1 .06" .61"
1 .07" .93"
074093401
½
1 .43" .59"
1 .34" 1 .19" .61"
1 .22" 1 .06"
074093402
³⁄₈
1 .31" .59"
1 .20" 1 .06" 1 .44" .60"
1 .13" .99"
¾
1 .56" .59"
1 .55" 1 .37" .84"
1 .43" 1 .25"
074093403
½
1 .31" .59"
1 .34" 1 .12" 1 .44" .61"
1 .21" 1 .00" 074093422
1
1 .68" .66"
1 .95" 1 .69" 1 .06" 1 .73" 1 .56"
074093404
¾
1 .44" .59"
1 .55" 1 .45" 1 .63" .83"
1 .48" 1 .29" 074093423
1¼
2 .03" .63"
2 .39" 2 .06" 1 .37" 2 .36" 2 .08"
074093405
1
1 .78" .66"
1 .95" 1 .60" 2 .19" 1 .05" 1 .80" 1 .57" 074093424
1½
2 .21" .63"
2 .72" 2 .38" 1 .53" 2 .79" 2 .48"
074093406
1¼
1 .97" .63"
2 .39" 2 .06" 2 .50" 1 .37" 2 .32" 2 .02" 074093425
2
2 .28" .69"
3 .08" 2 .87" 2 .06" 3 .32" 2 .90"
074093408
1½
2 .19" .66"
2 .72" 2 .38" 2 .69" 1 .61" 2 .58" 2 .25" 074093426
2
2 .53" .66"
3 .08" 2 .87" 3 .25" 2 .05" 3 .14" 2 .75" 074093428
Straight with Male Fitting with Insulated Throat
Dimensions
B
C
A/C* A/F*
D
Throat
E
Dia. A/C* A/F*
Catalog
Number
E
F
A/C* A/F*
G
Ref.
O
Throat
P
Dia.
A/C* A/F*
Trade D
Size
Trade A
Size Ref.
Catalog
Number
074093421
90° Angle with Male Fitting with Insulated Throat
Dimensions
E
F
A/C* A/F*
G
Ref.
O
Throat
P
Dia.
A/C* A/F*
1 .50" .66"
1 .20" 1 .06" .57"
1 .07" .93"
074093511
Catalog
Number
½
1 .50" .66"
1 .34" 1 .19" .57"
1 .22" 1 .06"
074093512
³⁄₈
1 .38" .66"
1 .20" 1 .06" 1 .44" .60"
1 .13" .99"
¾
1 .62" .66"
1 .55" 1 .38" .78"
1 .43" 1 .25"
074093513
½
1 .38" .66"
1 .34" 1 .12" 1 .44" .57"
1 .21" 1 .00" 074093542
1
1 .75" .72"
1 .95" 1 .69" .98"
1 .73" 1 .56"
074093514
¾
1 .50" .66"
1 .55" 1 .45" 1 .63" .78"
1 .48" 1 .29" 074093543
1¼
2 .09" .69"
2 .39" 2 .06" 1 .29" 2 .36" 2 .08"
074093515
1
1 .84" .66"
1 .95" 1 .60" 2 .19" .98"
1 .80" 1 .57" 074093544
2 .03" .69"
2 .39" 2 .06" 2 .50" 1 .29" 2 .32" 2 .02" 074093545
074093541
1½
2 .28" .69"
2 .72" 2 .37" 1 .53" 2 .79" 2 .48"
074093516
1¼
2
2 .34" .75"
3 .08" 2 .87" 1 .95" 3 .32" 2 .90"
074093518
1½
2 .25" .69"
2 .72" 2 .38" 2 .69" 1 .53" 2 .58" 2 .20" 074093546
074093520
2
2 .59" .72"
3 .08" 2 .87" 3 .25" 1 .95" 3 .14" 2 .75" 074093548
3 .44" 1 .00" 3 .92" 3 .63" 4 .25" 2 .42" 3 .78" 3 .50" 074093550
3 .75" 1 .00" 4 .70" 4 .31" 4 .87" 3 .01" 4 .64" 4 .30" 074093552
3 .56" 1 .06" 3 .92" 3 .62" 2 .42" 3 .85" 3 .60"
3
3 .81" 1 .06" 4 .70" 4 .31" 3 .01" 4 .65" 4 .33"
074093522
2½
4
3 .81" 1 .06" 5 .75" 5 .31" 3 .96" 5 .75" 5 .39"
074093526
3
Note: *A/C - Across Corners; A/F - Across Flats.
Dimensions shown are approximate and
are subject to change without notice.
Dimensions in Inches (cm)
www.hubbell-wiring.com
T-79
Technical Information
³⁄₈
Trade D
Size
2½
Kellems® Wire Management Products
Kellems® Wire Management Products
Kellems® Wire Management Products
Kellems® Wire Management Products
Technical Information
Strain Relief for Liquidtight Conduit
Dimensional Charts For UL Type A, Liquidtight Conduit Grip Fittings
Straight with Male Fitting with Insulated Throat
Dimensions Inches (cm)
Trade Size
N.P.T. Inches
A
B
C
D
Catalog Number
³⁄₈
½
¾
1
1 .922" (4 .88)
1 .922" (4 .88)
2 .016" (5 .12)
2 .157" (5 .48)
.594" (1 .51)
.594" (1 .51)
.594" (1 .51)
.719" (1 .83)
1 .156" (2 .94)
1 .250" (3 .17)
1 .500" (3 .81)
1 .844" (4 .68)
3 .75" (9 .52)
4 .50" (11 .43)
6 .25" (15 .87)
7 .50" (19 .05)
H038CNK
H050CNK
H075CNK
H100CNK
1¼
1½
2
2 .219" (5 .64)
2 .344" (5 .95)
2 .406" (6 .11)
.750" (1 .91)
.750" (1 .91)
.750" (1 .91)
2 .312" (5 .87)
2 .578" (6 .55)
3 .187" (8 .09)
9 .00" (22 .86)
13 .50" (34 .29)
14 .50" (36 .83)
H125CNK
H150CNK
H200CNK
C
Flats
B
Ref.
D
A
Ref.
90° Angle with Male Fitting with Insulated Throat
Dimensions Inches (cm)
Trade Size
N.P.T. Inches
E
F
G
H
I
Catalog Number
³⁄₈
½
¾
1
1 .250" (3 .18)
1 .281" (3 .25)
1 .438" (3 .65)
1 .750" (4 .44)
.594" (1 .51)
.594" (1 .51)
.594" (1 .51)
.719" (1 .83)
1 .156" (2 .94)
1 .250" (3 .17)
1 .500" (3 .81)
1 .844" (4 .68)
1 .453" (3 .69)
1 .453" (3 .69)
1 .000" (2 .54)
2 .125" (5 .40)
3 .75" (9 .52)
4 .50" (11 .43)
6 .25" (15 .87)
7 .50" (19 .05)
H0389CNK
H0509CNK
H0759CNK
H1009CNK
1¼
1½
2
1 .969" (5 .00)
2 .250" (5 .71)
2 .531" (6 .43)
.750" (1 .91)
.750" (1 .91)
.750" (1 .91)
2 .312" (5 .87)
2 .578" (6 .55)
3 .187" (8 .09)
2 .344" (5 .95)
2 .500" (6 .35)
2 .781" (7 .06)
9 .00" (22 .86)
13 .50" (34 .29)
14 .50" (36 .83)
H1259CNK
H1509CNK
H2009CNK
Technical Information
G
Flats
E
I
F
H
Dimensions shown are approximate and
are subject to change without notice.
T-80
www.hubbell-wiring.com
Dimensions in Inches (cm)
Cord Connectors
Features and Benefits
Machined threads provide a strong positive seal;
the tapered interior dome easily drives the
bushing into the connector body
The patented GOTHCA® ring incorporates a
split hinge design to prevent friction and
provide strain relief, also color-coded
for sizing identification
Kellems® Wire Management Products
Kellems® Wire Management Products
Lubricated neoprene bushing compresses easily
for a liquidtight seal and added pull-out protection
The connector body is a one-piece design with
machined threads; a tapered interior seats the
bushing evenly for a liquidtight seal
Hubbell has the broadest line and the widest choice of
materials in the industry . N .P .T . hub sizes from ¼" to 3" in
straight male end, 90°, 45°, female and underground feed
connectors . They are available in your choice of aluminum,
plated steel, nylon and stainless steel .
The zinc-plated steel cord connectors offers the strength
of steel and the corrosion resistance of zinc-plating . These
heavy-duty connectors hold up to most manufacturing
chemicals including acid solutions, solvents and other
corrosive materials .
Dimensions in Inches (cm)
Hubbell’s nylon cord connectors resist most common
industrial corrosives and provide highly effective pullout
protection in a lightweight design . They are ideal for any
application where weight, conductivity or corrosion may
be an issue . They’re available in N .P .T . hub sizes from
¼" to 1" .
Stainless steel cord connectors provide superior strength
and corrosion resistance for industrial and military
applications . They are machined from 300 series stainless
steel and come in ¼" to 1", N .P .T . hub sizes .
www.hubbell-wiring.com
T-81
Cord Connectors
Hubbell offers a full line of machined aluminum cord
connectors in N .P .T . hub sizes ¼" through 1" and cast
aluminum 1" to 3" . They provide durable performance and
a clean attractive look without adding unwanted weight .
N .P .T . hub sizes ¼" to 1" feature an attractive knurled finish
which makes them easy to handle and maintain a U .L .
listing by hand tightening .
Their machined steel nut and body allows for tightening
the compression nut and N .P .T . hub without worrying
about stripping the threads . For larger size cord, N .P .T .
hub sizes 1" to 2", Hubbell utilizes malleable iron
connectors which provide excellent holding and
liquidtight performance .
Kellems® Wire Management Products
Kellems® Wire Management Products
Straight Male Cord Connectors
UL Listed to Type 4,
4X, 12 and Type 13
Form Size 1-3
IP66*
SUITABILITY
Straight Male
N.P.T. Cord Dia.
Hub
Inches
Form
Size
(mm)
Size
¼
Machined
Aluminum
³⁄₈
Machined
Zinc-Plated Steel
½
Straight Male Cord Connectors
½
½
.06"- .13"
(1 .6-3 .2)
.13"- .19"
(3 .2-4 .7)
.19"- .25"
(4 .7-6 .3)
.25"- .31"
(6 .3-7 .9)
.31"- .38"
(7 .9-9 .5)
.38"- .44"
(9 .5-11)
.06"- .13"
(1 .6-3 .2)
.13"- .19"
(3 .2-4 .7)
.19"- .25"
(4 .7-6 .3)
.25"- .31"
(6 .3-7 .9)
.31"- .38"
(7 .9-9 .5)
.38"- .44"
(9 .5-11 .0)
.19"- .25"
(4 .7-6 .3)
.25"- .31"
(6 .3-7 .9)
.31"- .38"
(7 .9-9 .5)
.38"- .44"
(9 .5-11 .0)
.06"- .13"
(1 .6-3 .2)
.13"- .19"
(3 .2- .4 .7)
.19"- .25"
(4 .7-6 .3)
.25"- .38"
(6 .3- .9 .7)
.38"- .50"
(9 .7-12 .7)
.50"- .63"
(12 .7-15 .9)
.38"- .50"
(9 .7-12 .7)
.50"- .63"
(12 .7-15 .9)
.63"- .75"
(15 .9-19 .0)
.75"- .88"
(19 .0-22 .2)
F1
Color
Code
Machined
Aluminum
Machined
Zinc-Plated
Steel
Green
—
—
—
SHC1001CR
—
Orange SHC1002
—
—
SHC1002CR
—
Red
SHC1003
—
SHC1003SS
SHC1003CR
—
Black
SHC1004
—
SHC1004SS
SHC1004CR
—
White
SHC1005**
—
—
SHC1005CR
Blue
—
—
—
SHC1006CR
SHC1007
—
—
Green
Orange SHC1008
F1
F1
F2
—
—
Nylon
Black
—
SHC2005CR
—
—
SHC1008CR
Black
SHC1010
White
SHC1011
Blue
SHC1012
Red
SHC1015
—
—
—
—
Black
SHC1016
—
—
—
—
White
SHC1017
—
—
—
—
Blue
SHC1018
—
—
—
—
Green
SHC1019
—
—
—
SHC1012ZP
—
SHC1009CR
SHC2008CR
SHC1009
SHC1010ZP
SHC1009SS
Nylon
Gray
Red
—
SHC1010CR
SHC2010CR
SHC1011SS
SHC1011CR
SHC2011CR
SHC1012SS
SHC1012CR
SHC2012CR
SHC1019CR
—
—
Orange SHC1020
SHC1020ZP
SHC1020SS
SHC1020CR
Red
SHC1021
SHC1021ZP
SHC1021SS
SHC1021CR
SHC2021CR
White
SHC1022
SHC1022ZP
SHC1022SS
SHC1022CR
SHC2022CR
Blue
SHC1023
SHC1023ZP
SHC1023SS
SHC1023CR
SHC2023CR
Brown SHC1024
SHC1024ZP
SHC1024SS
SHC1024CR** SHC2024CR**
SHC1025
—
—
—
—
Brown SHC1026
—
—
—
—
Yellow SHC1027** SHC1027ZP**
—
—
—
Orchid SHC1028** SHC1028ZP**
—
—
—
Blue
F3
SHC1008ZP
Stainless
Steel
Note: See pages T-92 to T-101 for additional technical data and dimensional drawings.
* IP66 Suitability when used with optional metal clad O-ring shown on page T-89.
** Cable jacket may have to be stripped to pass through connector body.
Locknuts sold separately. See page T-89.
T-82
www.hubbell-wiring.com
Dimensions in Inches (cm)
Straight Male Cord Connectors
UL Listed to Type 4,
4X, 12 and Type 13
Form Size 2-4
IP66*
SUITABILITY
Straight Male
N.P.T. Cord Dia.
Hub
Inches
Form Color
Size
(mm)
Size Code
¾
¾
1
1
.06"- .13"
(1 .6-3 .2)
.13"- .19"
(3 .2-4 .7)
.19"- .25" F2
(4 .7-6 .3)
.25"- .38"
(6 .3-9 .7)
.38"- .50"
(9 .7-12 .7)
.50"- .63"
(12 .7-15 .9)
.38"- .50"
(9 .5-12 .7)
50"- .63"
F3
(12 .7-15 .9)
.63"- .75"
(15 .9-19 .0)
.75"- .88"
(19 .0-22 .2)
.50"- .63" F3
(12 .7-15 .9)
.63"- .75"
(15 .9-19 .0)
.75"- .88"
(19 .0-22 .2)
.38"- .50"
(9 .7-12 .7)
.50"- .63"
(12 .7-15 .9)
.63"- .75" F4
(15 .9-19 .0)
.75"- .88"
(19 .0-22 .2)
.88"-1 .00"
(22 .2-25 .4)
1 .00"-1 .13"
(25 .4-28 .6)
Machined
Aluminum
Green SHC1029
Machined
Zinc-Plated
Steel
Stainless
Steel
—
Nylon
Gray
—
—
—
Orange SHC1030
SHC1030ZP
—
—
—
Red
SHC1031
SHC1031ZP
—
—
—
White
SHC1032
SHC1032ZP
—
—
—
Blue
SHC1033
SHC1033ZP
—
—
—
Brown SHC1034
SHC1034ZP
—
—
—
Blue
—
Brown SHC1036
Yellow SHC1037
SHC1035ZP
—
SHC1037ZP
SHC1035SS
SHC1035CR
SHC2035CR
SHC1036SS
SHC1036CR
SHC2036CR
SHC1037SS
SHC1037CR
SHC2037CR
Stainless
Steel
Orchid SHC1038** SHC1038ZP** SHC1038SS** SHC1038CR** SHC2038CR**
Brown
—
SHC1097ZP
—
—
—
Yellow
—
SHC1098ZP
—
—
—
Orchid
—
SHC1099ZP
—
—
—
SHC1039
—
—
SHC1039CR
Brown SHC1040
—
—
SHC1040CR
SHC2040CR
Yellow SHC1041
—
SHC1041SS
SHC1041CR
SHC2041CR
Orchid SHC1042
—
SHC1042SS
SHC1042CR
SHC2042CR
SHC1043CR
SHC2043CR
Blue
Gray
SHC1043
Pink
SHC1044**
SHC1043ZP
—
—
Gray Nylon
—
SHC1044SS** SHC1044CR** SHC2044CR**
www.hubbell-wiring.com
Black Nylon
T-83
Straight Male Cord Connectors
Note: See pages T-92 to T-101 for additional technical data and dimensional drawings.
* IP66 Suitability when used with optional metal clad O-ring shown on page T-89.
** Cable jacket may have to be stripped to pass through connector body.
Form 4 aluminum and plated steel nuts are machined, bodies are cast aluminum.
Locknuts sold separately. See page T-89.
Dimensions in Inches (cm)
Nylon
Black
Kellems® Wire Management Products
Kellems® Wire Management Products
Kellems® Wire Management Products
Kellems® Wire Management Products
Straight Male Cord Connectors
UL Listed to Type 4,
4X, 12 and Type 13
Form Size 5-8
IP66*
SUITABILITY
Straight Male
N.P.T.
Hub Size
1
1¼
Cast Aluminum
1½
1½
2
Cast Aluminum
Malleable Iron
2
2½
Straight Male Cord Connectors
3
3
Cord Diameter
Inches
(mm)
.88"-1 .00"
1 .00"-1 .13"
1 .13"-1 .25"
1 .25"-1 .38"
.75"- .88"
.88"-1 .00"
1 .00"-1 .13"
1 .13"-1 .25"
1 .25"-1 .38"
.75"- .88"
.88"-1 .00"
1 .00"-1 .13"
1 .13"-1 .25"
1 .25"-1 .38"
1 .38"-1 .50"
1 .50"-1 .63"
1 .63"-1 .75"
1 .75"-1 .88"
1 .25"-1 .38"
1 .38"-1 .50"
1 .50"-1 .63"
1 .63"-1 .75"
1 .75"-1 .88"
1 .69"-1 .81"
1 .81"-1 .94"
1 .94"-2 .06"
2 .06"-2 .19"
2 .19"-2 .31"
1 .69"-1 .81"
1 .81"-1 .94"
1 .94"-2 .06"
2 .06"-2 .19"
2 .19"-2 .31"
2 .31"-2 .44"
1 .69"-1 .81"
1 .94"-2 .06"
2 .06"-2 .19"
2 .19"-2 .31"
2 .31"-2 .44"
2 .44"-2 .63"
2 .63"-2 .81"
2 .81"-3 .00"
3 .00"-3 .25"
(22 .2-25 .4)
(25 .4-28 .6)
(28 .6-31 .7)
(31 .7-34 .9)
(19 .0-22 .2)
(22 .2-25 .4)
(25 .4-28 .6)
(28 .6-31 .7)
(31 .7-34 .9)
(19 .0-22 .2)
(22 .2-25 .4)
(25 .4-28 .6)
(28 .6-31 .7)
(31 .7-34 .9)
(34 .9-38 .1)
(38 .1-41 .3)
(41 .3-44 .4)
(44 .4-47 .6)
(31 .7-34 .9)
(34 .9-38 .1)
(38 .1-41 .3)
(41 .3-44 .4)
(44 .4-47 .6)
(42 .9-46 .0)
(46 .0-49 .2)
(49 .2-52 .4)
(52 .4-55 .6)
(55 .6-58 .7)
(42 .9-46 .0)
(46 .0-49 .2)
(49 .2-52 .4)
(52 .4-55 .6)
(55 .6-58 .7)
(58 .7-61 .9)
(42 .9-46 .0)
(49 .2-52 .4)
(52 .4-55 .6)
(55 .6-58 .7)
(58 .7-61 .9)
(61 .9-66 .7)
(66 .7-71 .4)
(71 .4-76 .2)
(76 .2-82 .5)
Form
Size
F5
F5
F5
F6
F6
F7
F7
F7
F8
Cast Aluminum
Malleable Iron
SHC1046
SHC1047**
SHC1048**
SHC1049**
SHC1050
SHC1051
SHC1052
SHC1053
SHC1054**
SHC1055
SHC1056
SHC1057
SHC1058
SHC1059
SHC1061
SHC1062**
SHC1063**
SHC1064**
SHC1065
SHC1066
SHC1067
SHC1068
SHC1069
SHC1070
SHC1071
SHC1072**
SHC1073**
SHC1074**
SHC1076
SHC1077
SHC1078
SHC1079
SHC1080
SHC1081**
SHC1086
SHC1088
SHC1089
SHC1090
SHC1091
SHC1092
SHC1093
SHC1094
SHC1095**
—
—
—
—
—
—
SHC1052ZP
SHC1053ZP
SHC1054ZP
—
—
SHC1057ZP
SHC1058ZP
SHC1059ZP
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Note: See pages T-92 to T-101 for additional technical data and dimensional drawings.
* IP66 Suitability when used with optional metal clad O-ring shown on page T-89.
** Cable jacket may have to be stripped to pass through connector body.
Form 4 aluminum and plated steel nuts are machined, bodies are cast aluminum.
F5 and larger will not be color coded.
Locknuts sold separately. See page T-89.
T-84
www.hubbell-wiring.com
Dimensions in Inches (cm)
45° Male Cord Connectors
UL Listed to Type 4,
4X, 12 and Type 13
Form Size 2-5
IP66*
SUITABILITY
45° Male
N.P.T.
Hub
Size
½
¾
1
1¼
Cord Diameter
Inches
(mm)
.19"- .25"
.25"- .38"
.38"- .50"
.50"- .63"
.38"- .50"
.50"- .63"
.63"- .75"
.63"- .75"
.75"- .88"
1 .00"-1 .13"
1 .13"-1 .25"
(4 .7-6 .3)
(6 .3-9 .7)
(9 .7-12 .7)
(12 .7-15 .9)
(9 .7-12 .7)
(12 .7-15 .9)
(15 .9-19 .0)
(15 .9-19 .0)
(19 .0-22 .2)
(25 .4-28 .6)
(28 .6-31 .7)
Form
Size
F2
F3
F4
F5
Color
Code
Red
White
Blue
Brown
Blue
Brown
Yellow
Yellow
Orchid
Machined
Machined
Aluminum†
Zinc-Plated
Steel∆
Cast
Aluminum
VHC1021
VHC1022
VHC1023
VHC1024**
VHC1035
VHC1036
VHC1037**
VHC1041
VHC1042
—
—
—
VHC1022ZP
VHC1023ZP
VHC1024ZP**
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
VHC1052
VHC1053**
Machined
Aluminum †
Kellems® Wire Management Products
Kellems® Wire Management Products
Note: See pages T-92 to T-101 for additional technical data and dimensional drawings.
* IP66 Suitability when used with optional metal clad O-ring shown on page T-89.
** Cable jacket may have to be stripped to pass through connector body.
Form 4 aluminum and plated steel nuts are machined, bodies are cast aluminum.
† Nuts are machined aluminum and bodies are cast aluminum.
∆ Nuts are machined zinc-plated steel and bodies are malleable iron, cadmium plated.
Locknuts sold separately. See page T-89.
Machined
Zinc-Plated Steel ∆
Cast Aluminum
45° Male Cord Connectors
Dimensions in Inches (cm)
www.hubbell-wiring.com
T-85
Kellems® Wire Management Products
Kellems® Wire Management Products
90° Male Cord Connectors
UL Listed to Type 4,
4X, 12 and Type 13
Form Size 1-6
IP66*
SUITABILITY
90° Male
N.P.T.
Hub
Size
³⁄₈
½
¾
1
1¼
1½
2
Cord Diameter
Inches
(mm)
.25"- .31"
.31"- .38"
.38"- .44"
.06"- .13"
.13"- .19"
.19"- .25"
.25"- .38"
.38"- .50"
.50"- .63"
.38"- .50"
.50"- .63"
.63"- .75"
.75"- .88"
.50"- .63"
.63"- .75"
.75"- .88"
.88"-1 .00"
1 .00"-1 .13"
.88"-1 .00"
1 .00"-1 .13"
1 .13"-1 .25"
1 .25"-1 .38"
1 .00"-1 .13"
1 .13"-1 .25"
1 .25"-1 .38"
1 .38"-1 .50"
(6 .3-7 .9)
(7 .9-9 .5)
(9 .5-11 .0)
(1 .6-3 .2)
(3 .2-4 .7)
(4 .7-6 .3)
(6 .3-9 .7)
(9 .7-12 .7)
(12 .7-15 .9)
(9 .7-12 .7)
(12 .7-15 .9)
(15 .9-19 .0)
(19 .0-22 .2)
(12 .7-15 .9)
(15 .9-19 .0)
(19 .0-22 .2)
(22 .2-25 .4)
(25 .4-28 .7)
(22 .2-25 .4)
(25 .4-28 .6)
(28 .6-31 .7)
(31 .7-34 .9)
(25 .4-28 .6)
(28 .6-31 .7)
(31 .7-34 .9)
(34 .9-38 .1)
Form
Size
F1
F2
F3
F4
F5
F5
F6
Color
Code
Machined
Aluminum†
Machined
Zinc-Plated
Steel∆
Nylon
Gray
Nylon
Black
Cast
Aluminum
Black
White
Blue
Green
Orange
Red
White
Blue
Brown
Blue
Brown
Yellow
Orchid
Brown
Yellow
Orchid
Gray
Pink
—
—
—
—
—
—
—
—
NHC1010
NHC1011
NHC1012
—
NHC1020
NHC1021
NHC1022
NHC1023
NHC1024**
NHC1035
NHC1036
NHC1037
NHC1038
NHC1040
NHC1041
NHC1042
NHC1043**
NHC1044**
—
—
—
—
—
—
—
—
—
—
—
—
—
NHC1021ZP
NHC1022ZP
NHC1023ZP
NHC1024ZP**
NHC1035ZP
NHC1036ZP
NHC1037ZP
NHC1038ZP
—
NHC1041ZP
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
NHC1020CR
NHC1021CR
NHC1022CR
NHC1023CR
NHC1024CR**
NHC1035CR
NHC1036CR
NHC1037CR
NHC1038CR
—
NHC1041CR
NHC1042CR
NHC1043CR
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
NHC2022CR
NHC2023CR
NHC2024CR**
—
—
—
—
—
NHC2041CR
NHC2042CR**
NHC2043CR**
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
NHC1051
NHC1052
NHC1053**
NHC1054**
NHC1057
—
NHC1059
NHC1066
90° Male Cord Connectors
Note: See pages T-92 to T-101 for additional technical data and dimensional drawings.
* IP66 Suitability when used with optional metal clad O-ring shown on page T-89.
** Cable jacket may have to be stripped to pass through connector body.
† Nuts are machined aluminum and bodies are cast aluminum.
∆ Compression nuts are machined zinc-plated steel and bodies are zinc-plated malleable iron.
Locknuts sold separately. See page T-89.
Machined
Aluminum†
Gray Nylon
T-86
Machined
Zinc-Plated Steel∆
Black Nylon
www.hubbell-wiring.com
Cast Aluminum
Dimensions in Inches (cm)
Straight Female, Underground Feeder and Metric Connectors
Form Size 1-4
Straight Female
N.P.T.
Hub
Size
½
¾
1
Cord Diameter
Inches
(mm)
Form
Size
Color
Code
Machined
Aluminum
.25"- .38"
.38"- .50"
.38"- .50"
.50"- .63"
.75"- .88"
.88"-1 .00"
F2
White
Blue
Blue
Brown
Orchid
Gray
FHC1022
FHC1023
FHC1033
FHC1034
FHC1042†
FHC1043†
(6 .3-9 .7)
(9 .7-12 .7)
(9 .7-12 .7)
(12 .7-15 .9)
(19 .0-22 .2)
(22 .2-25 .4)
F2
F4
Machined
Aluminum
Note: See pages T-92 to T-101 for additional technical data and dimensional drawings.
* Cable jacket may have to be stripped to pass through connector body.
† Nuts are machined aluminum and bodies are cast aluminum.
Kellems® Wire Management Products
Kellems® Wire Management Products
IP66*
SUITABILITY
Underground Feeder Connectors
(mm)
½
.2"x .4" min
.25"- .55" max
(5 .1 x 10 .2)
(6 .3 x 14 .0)
¾
.2"x .4" min
.25"- .55" max
(5 .1x10 .2)
(6 .3x14 .0)
¾
.2"x .6" min
.26"x .78" max
(5 .1x15 .2)
(6 .6x19 .8)
Wire
Size
2 # 14,
2 # 12,
2 # 10 .
2 # 14,
2 # 12,
2 # 10 .
3 # 14,
3 # 12,
3 # 10 .
UF**
Machined
Aluminum
Zinc-Plated
Steel
Machined
Nylon
Gray
Nylon
Black
UFC0001
UFC0001ZP
UFC0001CR
UFC2001CR
UFC0002
—
UFC0003
—
—
UFC0003CR
Note: See pages T-92 to T-101 for additional technical data and dimensional drawings.
* IP66 Suitability when used with optional metal clad O-ring shown on page T-89.
** Wire sizes vary among manufacturers.
Locknuts sold separately. See page T-89.
Machined
Aluminum
—
UFC2003CR
Machined
Zinc-Plated Steel
UL Listed to Type 4,
4X, 12 and Type 13 †
Metric Aluminum Cord Connectors
Hub
Size
Cord Diameter
Inches
(mm)
Form
Size
M16
M20
.31"- .38"
.31"- .38"
.25"- .38"
.38"- .50"
.50"- .62"
.38"- .50"
.50"- .62"
.63"-75"
F1
F1
M20
M25
M30
(7 .9-9 .7)
(7 .9-9 .7)
(6 .3-9 .7)
(9 .7-12 .7)
(12 .7-15 .8)
(9 .7-12 .7)
(12 .7-15 .8)
(15 .9-19 .0)
Catalog Number
SHCM161011
SHCM201017
SHCM201022
SHCM201023
SHCM201024
SHCM251033
SHCM251034
SHCM301037
F2
F2
F3
Gray Nylon
Note: † When used with metal clad O-ring shown on page T-89.
Non-metallic Locknuts sold separately. See page T-88.
Machined
Aluminum
Dimensions in Inches (cm)
www.hubbell-wiring.com
T-87
Straight Female, Underground Feeder and Metric Connectors
N.P.T.
Hub Diameter
Size Inches
Kellems® Wire Management Products
Kellems® Wire Management Products
Low Profile N.P.T., PG and Metric Thread Connectors
Non-Metallic Cord Connectors
IP66*
SUITABILITY
Low Profile N.P.T. Cord Connectors
SEC100BA
N.P.T.
Hub Size
Inches
Cord Diameter
(mm)
Color
Catalog
Number
Non-metallic
Locknuts
³⁄₈
³⁄₈
½
½
¾
¾
1
1
.18"- .31"
.18"- .31"
.17"- .45"
.17"- .45"
.45"- .71"
.45"- .71"
.59"-1 .00"
.59"-1 .00"
(4 .6-7 .9)
(4 .6-7 .9)
(4 .3-11 .4)
(4 .3-11 .4)
(11 .4-18 .0)
(11 .4-18 .0)
(15-25 .4)
(15-25 .4)
Gray
Black
Gray
Black
Gray
Black
Gray
Black
SEC38GA*
SEC38BA*
SEC50GA
SEC50BA
SEC75GA
SEC75BA
SEC100GA
SEC100BA
31622002LPK50
31622002LPK50
31622003LPK50
31622003LPK50
31622007LPK50
31622007LPK50
31622008LPK50
31622008LPK50
Note: See pages T-92 to T-101 for additional technical data and dimensional drawings.
Catalog numbers with “PK50” suffix are bulk packed 50 pieces.
Low Profile PG∆ Cord Connectors
Low Profile N .P .T ., PG and Metric Thread Connectors
SECP29GA
Hub Size
Cord Diameter
Inches
(mm)
Color
Catalog
Number
Non-metallic
Locknuts
PG7
PG7
PG9
PG9
PG11
PG11
PG13 .5
PG13 .5
PG16
PG16
PG21
PG21
PG29
PG29
PG36
PG36
.11"- .25"
.11"- .25"
.18"- .31"
.18"- .31"
.23"- .40"
.23"- .40"
.17"- .47"
.17"- .47"
.23"- .53"
.23"- .53"
.45"- .71"
.45"- .71"
.59"- .99"
.59"- .99"
.88"-1 .30"
.88"-1 .30"
Gray
Black
Gray
Black
Gray
Black
Gray
Black
Gray
Black
Gray
Black
Gray
Black
Gray
Black
SECP7GA*
SECP7BA*
SECP9GA*
SECP9BA*
SECP11GA*
SECP11BA*
SECP13GA
SECP13BA
SECP16GA
SECP16BA
SECP21GA
SECP21BA
SECP29GA
SECP29BA
SECP36GA
SECP36BA
LNP7BPK100
LNP7BPK100
LNP9BPK100
LNP9BPK100
LNP11BPK100
LNP11BPK100
LNP13BPK100
LNP13BPK100
LNP16BPK100
LNP16BPK100
LNP21BPK100
LNP21BPK100
LNP29BPK25
LNP29BPK25
LNP36BPK25
LNP36BPK25
(2 .9-6 .4)
(2 .9-6 .4)
(4 .6-7 .9)
(4 .6-7 .9)
(5 .8-10 .0)
(5 .8-10 .0)
(4 .3-11 .9)
(4 .3-11 .9)
(5 .8-13 .5)
(5 .8-13 .5)
(11 .4-17 .9)
(11 .4-17 .9)
(15-25 .2)
(15-25 .2)
(22 .2-32 .0)
(22 .2-32 .0)
Low Profile Metric Cord Connectors
LNP29BPK25
Hub Size
Cord Diameter
Inches
(mm)
Color
Catalog
Number
Non-metallic
Locknuts
M12
M12
M16
M16
M20
M20
M25
M25
M32
M32
M40
M40
.12"- .25"
.12"- .25"
.11"- .31"
.11"- .31"
.17"- .45"
.17"- .45"
.49"- .71"
.49"- .71"
.59"-1 .00"
.59"-1 .00"
.87"-1 .30"
.87"-1 .30"
Gray
Black
Gray
Black
Gray
Black
Gray
Black
Gray
Black
Gray
Black
SECM12G
SECM12B
SECM16G
SECM16B
SECM20G*
SECM20B*
SECM25G*
SECM25B*
SECM32G*
SECM32B*
SECM40G
SECM40B
LNM12BPK100
LNM12BPK100
LNM16BPK100
LNM16BPK100
LNM20BPK100
LNM20BPK100
LNM25BPK100
LNM25BPK100
LNM32BPK100
LNM32BPK100
LNM40BPK100
LNM40BPK100
(2 .9-6 .4)
(2 .9-6 .4)
(2 .7-7 .9)
(2 .7-7 .9)
(4 .3-11 .4)
(4 .3-11 .4)
(12 .3-18 .0)
(12 .3-18 .0)
(15 .0-25 .4)
(15 .0-25 .4)
(22 .0-32 .0)
(22 .0-32 .0)
Note: See pages T-92 to T-101 for additional technical data and dimensional data.
Catalog numbers above with “PK100” suffix, i.e. LNP7BPK100, are bulk packed 100 per carton.
Catalog numbers above with “PK25” suffix, i.e. LNP29BPK25, are bulk packed 25 per carton.
* Items indicated are UL recognized components.
∆ Panzergewinde.
T-88
www.hubbell-wiring.com
Dimensions in Inches (cm)
Accessories
Cord Connector Parts
N.P.T.
Hub Size
Cord Diameter
Inches
(mm)
¼, ³⁄₈, ½
.062"- .125"
.125"- .187"
.187"- .250"
.250"- .312"
.312"- .375"
.375"- .437"
.187"- .250"
.250"- .375"
.375"- .500"
.500"- .625"
.375"- .500"
.500"- .625"
.625"- .750"
.750"- .875"
.500"- .625"
.625"- .750"
.750"- .875"
.875"-1 .00"
1 .00"-1 .125"
½, ¾
½, ¾
1
(1 .58-3 .17)
(3 .17-4 .76)
(4 .76-6 .35)
(6 .35-7 .93)
(7 .93-9 .50)
(9 .50-11 .1)
(4 .76-6 .35)
(6 .35-9 .50)
(9 .50-12 .7)
(12 .7-15 .8)
(9 .50-12 .7)
(12 .7-15 .8)
(15 .8-19 .0)
(19 .0-22 .2)
(12 .7-15 .8)
(15 .8-19 .0)
(19 .0-22 .2)
(22 .2-25 .4)
(25 .4-28 .5)
Form
Size
F1
F2
F3
F4
Bushing
Catalog Number
Color Code
GOTCHA® Ring
Catalog Number
31518101BPK100
31518102BPK100
31518103BPK100
31518104BPK100
31518105BPK100
31518106BPK100
31518110BPK100
31518111BPK100
31518112BPK100
31518113BPK100
31518116BPK100
31518117BPK100
31518118BPK100
31518119BPK100
31518123BPK100
31518124BPK100
31518125BPK100
31518126BPK100
31518127BPK100
Green
Orange
Red
Black
White
Blue
Red
White
Blue
Brown
Blue
Brown
Yellow
Orchid
Brown
Yellow
Orchid
Gray
Pink
31648035GPK100
31648036GPK100
31648037GPK100
31648038GPK100
31605010GPK100
31648039GPK100
31648042GPK100
31605015GPK100
31648043GPK100
31648044GPK100
31648045GPK100
31648046GPK100
31648047GPK100
31648048GPK100
31648050GPK100
31648051GPK100
31648052GPK100
31648053GPK100
31648054GPK100
Kellems® Wire Management Products
Kellems® Wire Management Products
Note: Catalog numbers above with “PK100” suffix, i.e. 31518101BPK100, are bulk packed 100 per carton.
Locknuts — Steel and Non-Metallic
N.P.T.
Hub Size
Zinc-Plated Steel
Non-Metallic
¼
³⁄₈
½
¾
1
1¼
1½
—
—
00322001LPK50
00322002LPK50
00322003LPK50
00322004LPK50
00322005LPK50
31622001LPK50
31622002LPK50
31622003LPK50
31622007LPK50
31622008LPK50
—
—
Zinc-Plated
Steel Locknuts
Note: Catalog numbers above with “PK50” suffix, i.e. 00322001LPK50, are bulk packed 50 per carton.
See page T-101 for additional technical data and dimensional drawings.
Metal Clad Sealing O-Rings
Catalog Number
½
¾
1
1¼
1½
2
2½
3
20509001
20509002
20509003
20509004
20509005
20509006
20509007
20509008
Note: See page T-101 for additional technical data and dimensional drawings.
Dimensions in Inches (cm)
www.hubbell-wiring.com
Non-Metallic
Locknuts
Metal Clad
Sealing O-Rings
T-89
Accessories
N.P.T.
Hub Size
Kellems® Wire Management Products
Kellems® Wire Management Products
Hubbell Juniors® Miniature Connectors
Hubbell Juniors are a miniature liquidtight version of the full-sized Hubbell cord connectors . They feature
the same GOTCHA® ring technology and neoprene bushings . They also come with or without a nylon
spiral for arc-of-bend control and longer cord life . They are available in ¼", ³⁄₈", and ½" N .P .T . sizes
in both gray and black .
Hubbell Juniors® Miniature Connectors
Nylon spiral provides arc-of-bend control for cord protection
Nylon compression nut has a tapered interior dome
to easily drive the bushing into the connector body
Patented GOTCHA® ring incorporates
a split hinge design to prevent friction
and provide strain relief
Lubricated neoprene bushing compresses evenly for
a liquidtight seal and added pull-out protection
Nylon connector body is a one piece design with a tapered
interior that seals the bushing evenly for a positive seal
Threaded hexagon shaped nylon locknut secures tightly
and is also corrosion resistant
T-90
www.hubbell-wiring.com
Hubbell Juniors® Miniature Nylon Cord Connectors
Miniature Nylon Cord Connector
N.P.T.
Hub Size
¼
³⁄₈
½
Cord Diameter Range
Inches
(mm)
Gray
Black
.08"- .14"
.14"- .20"
.20"- .27"
.15"- .21"
.21"- .28"
.28"- .34"
.06"- .13"
.13"- .19"
.19"- .25"
.25"- .31"
.31"- .38"
.38"- .44"
HJ1001GPK25
HJ1002GPK25
HJ1003GPK25
HJ1004GPK25
HJ1005GPK25
HJ1006GPK25
HJ1055GPK25
HJ1056GPK25
HJ1057GPK25
HJ1058GPK25
HJ1059GPK25
HJ1060GPK25
HJ1001BPK25
HJ1002BPK25
HJ1003BPK25
HJ1004BPK25
HJ1005BPK25
HJ1006BPK25
HJ1055BPK25
HJ1056BPK25
HJ1057BPK25
HJ1058BPK25
HJ1059BPK25
HJ1060BPK25
(1 .9-3 .4)
(3 .4-5 .1)
(5 .1-6 .7)
(3 .7-5 .3)
(5 .3-7 .0)
(7 .0-8 .6)
(1 .6-3 .2)
(3 .2-4 .7)
(4 .7-6 .3)
(6 .3-7 .9)
(7 .9-9 .5)
(9 .5-11 .1)
Gray Cord Connector
Kellems® Wire Management Products
Kellems® Wire Management Products
Black Cord Connector
Miniature Nylon Cord Connector with Spiral
N.P.T.
Hub Size
¼
½
¾
Gray
Black
.08"- .14"
.14"- .20"
.20"- .27"
.15"- .21"
.21"- .28"
.28"- .34"
.13"- .19"
.19"- .25"
.25"- .31"
.31"- .38"
.38"- .44"
.25"- .49"
.45"- .71"
HJ1010GPK25
HJ1011GPK25
HJ1012GPK25
HJ1013GPK25
HJ1014GPK25
HJ1015GPK25
HJ1038GPK25
HJ1039GPK25
HJ1040GPK25
HJ1041GPK25
HJ1042GPK25
HJ1043GPK25*
HJ1044GPK25*
HJ1010BPK25
HJ1011BPK25
HJ1012BPK25
HJ1013BPK25
HJ1014BPK25
HJ1015BPK25
HJ1038BPK25
HJ1039BPK25
HJ1040BPK25
HJ1041BPK25
HJ1042BPK25
HJ1043BPK25*
HJ1044BPK25*
(1 .9-3 .4)
(3 .4-5 .1)
(5 .1-6 .7)
(3 .7-5 .3)
(5 .3-7 .0)
(7 .0-8 .6)
(3 .2-4 .7)
(4 .7-6 .3)
(6 .3-7 .9)
(7 .9-9 .5)
(9 .5-11 .1)
(6 .4-12 .3)
(11 .4-18 .0)
Gray Cord Connector with Spiral
Black Cord Connector with Spiral
Note: * Locknuts sold separately. See page T-89.
Miniature Nylon Snap-In Cord Connector with Spiral
Gray Snap-In
Cord Connector
Cord Diameter Range
Inches
(mm)
For Chassis
Thickness
Gray
Black
.22"- .27"
.28"- .32"
.30"- .36"
.32"- .43"
.10" (2 .5) Max
.10" (2 .5) Max
.13" (3 .2) Max
.13" (3 .2) Max
HS1001GPK25
HS1002GPK25
HS1003GPK25
HS1004GPK25
HS1001BPK25
HS1002BPK25
HS1003BPK25
HS1004BPK25
(5 .6-6 .9)
(7 .1-8 .1)
(7 .6-9 .1)
(8 .1-10 .9)
Note: Catalog numbers above with “PK25” suffix, i.e. HJ1001GPK25, are bulk packed 25 per carton.
See pages T-102 and T-103 for additional technical data and dimensional drawings.
Black Snap-In
Cord Connector
Dimensions in Inches (cm)
www.hubbell-wiring.com
T-91
Hubbell Juniors® Miniature Nylon Cord Connectors
³⁄₈
Cord Diameter Range
Inches
(mm)
Kellems® Wire Management Products
Kellems® Wire Management Products
Technical Information
Cord Connectors
Operating Temperatures
Material
Aluminum
Nylon (connectors and GOTCHA® rings)
Plated steel*
Stainless steel*
Neoprene (bushings)
Temperature Range
-40°F to +300°F (-40°C to +149°C)
-40°F to +225°F (-40°C to +107°C)
-60°F to +1000°F (-51°C to +537°C)
-60°F to +1000°F (-51°C to +537°C)
-30°F to +240°F (-34°C to +115°C)
Note: * Due to the limiting factors of nylon and neoprene, any complete cord connector with a GOTCHA ring, Form 1-5, will continuously
perform in the range of -30°F to +225°F (-34°C to +107°C).
Cord connectors without GOTCHA rings, Form 6-8, will continuously operate in the range -30°F to +240°F (-34°C to +115°C)
due to the limiting factor of neoprene.
Hazardous Locations
Hubbell cord connectors are suitable for use in hazardous locations per Class I Div . 2, Class II Div . 1 & 2, Class Ill Div . 1 & 2 in
accordance with the NEC .
Flammability
Hubbell nylon cord connectors have a UL 94-V2 rating .
Approvals
Agency
UL Listed in accordance with Standard 514B .
CSA Certified .
United States Coast Guard Approved, Title 46-Part 111 .
Form Size Definition
The term “Form Size” refers to the physical overall size of a cord connector .
Form 1 is the smallest size .
Form 8 is the largest size .
Technical Information
Knockout Holes
N.P.T.
Hub Size
Knockout Hole Recommended
Min. to Max.
Inches
(mm)
Knockout Hole Recommended
PG
Hub Size
Inches (mm)
Knockout Hole Recommended
Metric
Hub Size
Inches (mm)
¼
³⁄₈
½
¾
1
1¼
1½
2
2½
3
.54"- .57"
.67"- .70"
.86"- .91"
1 .04"-1 .09"
1 .36"-1 .41"
1 .72"-1 .77"
1 .97"-2 .02"
2 .45"-2 .50"
2 .95"-3 .00"
3 .58"-3 .63"
PG7
PG9
PG11
PG13 .5
PG16
PG21
PG29
PG36
M12
M16
M20
M25
M32
M40
(13 .7-14 .5)
(17 .0-17 .8)
(21 .8-23 .0)
(26 .4-27 .8)
(34 .5-35 .7)
(43 .7-44 .9)
(50 .0-51 .2)
(62 .3-63 .5)
(75 .0-76 .2)
(90 .9-92 .1)
492"
599"
.733"
.804"
.888"
1 .15"
1 .47"
1 .85"
(12 .5)
(15 .2)
(18 .6)
(20 .4)
(22 .5)
(28 .3)
(34 .3)
(47 .0)
.472"
.629"
.787"
.984"
1 .25"
1 .57"
(12)
(16)
(20)
(25)
(32)
(40)
N.P.T., PG and Metric Thread Low Profile Connectors
Specifications
Material
Gland
Temperature Range
Protection Class
Flammability
Listings/Certifications
6/6 Nylon .
Buna N .
-22°F to 225°F (-30°C to 107°C) .
Cord Connectors are Halogen and Silicon free .
IP66 Suitability .
UL 94V-2 .
UL Listing File E-41567, UL Recognition File E-41567 .
CSA File LR27378C, VDE Marks Licence #136681 .
SECP29G
T-92
www.hubbell-wiring.com
Dimensions in Inches (cm)
Technical Information
Cord Connectors
Straight Hubbell Connectors
Aluminum Inches (mm)
F
A
N.P.T.
Form
¼-18
1
³⁄₈-18
1
½-14
1
½-14
2
½-14
3
¾-14
2
¾-14
3
1-11½
4
1-11½
5
1¼-11½
5
1½-11½
5
1½-11½
6
2-11½
6
2-11½
7
2½-8
7
2½-8
8
3-8
7
3-8
8
B
Dia.
Ref.
.88"
(22 .4)
.88"
(22 .4)
.88"
(22 .4)
1 .13"
(28 .7)
1 .38"
(35 .1)
1 .13"
(28 .7)
1 .38"
(35 .1)
1 .75"
(44 .4)
2 .31"
(58 .7)
2 .31"
(58 .7)
2 .31"
(58 .7)
3 .00"
(76 .2)
3 .00"
(76 .2)
3 .85"
(97 .8)
3 .85"
(97 .8)
4 .75"
(120 .6)
3 .85"
(97 .8)
4 .50"
(114 .3)
.90"
(22 .9)
.90"
(22 .9)
.90"
(22 .9)
1 .10"
(27 .9)
1 .50"
(38 .1)
1 .10"
(27 .9)
1 .50"
(38 .1)
1 .60"
(40 .6)
1 .70"
(43 .2)
1 .70"
(43 .2)
1 .70"
(43 .2)
2 .20"
(55 .9)
2 .20"
(55 .9)
2 .70"
(68 .6)
2 .70"
(68 .6)
2 .70"
(68 .6)
2 .70"
(68 .6)
2 .70"
(68 .6)
Nylon Inches (mm)
C
D
Throat
Dia.
E
A
B
C
D
Throat
Dia.
A/C*
A/F*
Dia.
Ref.
.46"
(11 .7)
.46"
(11 .7)
.46"
(11 .7)
.55"
(14 .0)
.55"
(14 .0)
.55"
(14 .0)
.55"
(14 .0)
.71"
(18 .0)
.66"
(16 .8)
.74"
(18 .8)
.74"
(18 .8)
.75"
(19 .0)
.80"
(20 .3)
.88"
(22 .4)
1 .30"
(33 .0)
1 .25"
(31 .7)
1 .30"
(33 .0)
1 .38"
(35 .1)
.32"
(8 .1)
.44"
(11 .2)
.44"
(11 .2)
.64"
(16 .3)
.64"
(16 .3)
.64"
(16 .3)
.82"
(20 .8)
1 .02"
(25 .9)
1 .01"
(25 .7)
1 .26"
(32 .0)
1 .38"
(35 .1)
1 .50"
(38 .1)
1 .92"
(48 .8)
1 .94"
(49 .3)
2 .32"
(58 .9)
2 .38"
(60 .5)
2 .54"
(64 .5)
3 .00"
(76 .2)
.99"
(25 .1)
.99"
(25 .1)
1 .00"
(25 .4)
1 .11"
(28 .2)
1 .40"
(35 .6)
1 .29"
(32 .8)
1 .40"
(35 .6)
1 .81"
(46 .0)
2 .28"
(57 .9)
2 .28"
(57 .9)
2 .28"
(57 .9)
2 .97"
(75 .4)
3 .24"
(82 .4)
4 .05"
(102 .9)
4 .34"
(110 .2)
4 .86"
(123 .4)
4 .34"
(110 .2)
4 .86"
(123 .4)
.88"
(22 .4)
.88"
(22 .4)
.88"
(22 .4)
1 .00"
(25 .4)
1 .25"
(31 .7)
1 .13"
(28 .7)
1 .25"
(31 .7)
1 .62"
(41 .1)
2 .00"
(50 .8)
2 .12"
(53 .8)
2 .12"
(53 .8)
2 .75"
(69 .8)
3 .00"
(76 .2)
3 .75"
(95 .2)
4 .02"
(102 .1)
4 .50"
(114 .3)
4 .02"
(102 .1)
4 .50"
(114 .3)
1 .00"
(25 .4)
1 .00"
(25 .4)
1 .00"
(25 .4)
1 .32"
(33 .5)
—
E
A/C*
A/F*
1 .10"
(27 .9)
1 .10"
(27 .9)
1 .10"
(27 .9)
1 .50"
(38 .1)
—
.43"
(10 .9)
.43"
(10 .9)
.46"
(11 .7)
.53"
(13 .5)
—
.33"
(8 .4)
.45"
(11 .4)
.45"
(11 .4)
.58"
(14 .7)
—
.1 .00"
(25 .4)
1 .00"
(25 .4)
1 .00"
(25 .4)
1 .25"
(31 .7)
—
.93"
(23 .6)
.93"
(23 .6)
.93"
(23 .6)
1 .12"
(28 .4)
—
—
—
—
—
—
—
1 .56"
(39 .6)
1 .88"
(47 .8)
—
1 .60"
(40 .6)
1 .75"
(44 .4)
—
.55"
(14 .0)
.70"
(17 .8)
—
.77"
(19 .6)
1 .01"
(25 .7)
—
1 .44"
(36 .6)
1 .84"
(46 .7)
—
1 .31"
(33 .3)
1 .63"
(41 .4)
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Kellems® Wire Management Products
Kellems® Wire Management Products
Note: *A/C— Across Corners; A/F—Across Flats.
A
(Overall)
Technical Information
B Ref.
E
F
C
D
Dimensions shown are approximate and
are subject to change without notice.
Dimensions in Inches (cm)
www.hubbell-wiring.com
T-93
Kellems® Wire Management Products
Kellems® Wire Management Products
Technical Information
Cord Connectors
Straight Hubbell Connectors
Zinc-Plated Steel Inches (mm)
F
A
B
Stainless Steel Inches (mm)
C
D
Throat
Dia.
E
A
B
C
D
Throat
Dia.
E
N.P.T.
Form
A/C*
A/F*
Ref.
A/C*
A/F*
A/C*
A/F*
A/C*
A/F*
¼- 18
1
—
—
—
—
—
—
—
³⁄₈-18
1
½-14
1
1 .30"
(33 .0)
—
1 .13"
(28 .7)
—
1 .10"
(27 .9)
—
.54"
(13 .7)
—
.63"
(16 .0)
—
1 .16"
(29 .5)
—
1 .00"
(25 .4)
—
—
—
—
—
—
—
—
¾-14
3
1-11½
3
1 .59"
(40 .4)
—
1 .38"
(35 .1)
—
1 .30"
(33 .0)
—
.56"
(14 .2)
—
.81"
(20 .6)
—
1 .44"
(36 .6)
—
1 .25"
(31 .7)
—
1-11½
4
1-11½
5
2 .02"
(51 .3)
—
1 .75"
(44 .4)
—
1 .40"
(35 .6)
—
.70"
(17 .8)
—
1 .03"
(26 .2)
—
1 .88"
(47 .8)
—
1 .63"
(41 .4)
—
1¼-11½
5
—
—
—
—
—
—
—
1½-11½
5
—
—
—
—
—
—
—
1½-11½
6
—
—
—
—
—
—
—
2-11½
6
—
—
—
—
—
—
—
2-11½
7
—
—
—
—
—
—
—
2½-8
7
—
.88"
(22 .4)
.88"
(22 .4)
1 .00"
(25 .4)
1 .25"
(31 .7)
1 .13"
(28 .7)
1 .25"
(31 .7)
1 .38"
(35 .1)
1 .69"
(42 .9)
2 .15"
(54 .6)
2 .19"
(55 .6)
2 .19"
(55 .6)
2 .83"
(71 .9)
3 .07"
(78 .0)
3 .89"
(98 .8)
—
.75"
(19 .0)
.75"
(19 .0)
—
2
.99"
(25 .1)
1 .00"
(25 .4)
1 .10"
(28 .2)
1 .40"
(35 .6)
1 .29"
(32 .8)
1 .40"
(35 .6)
1 .54"
(39 .1)
1 .95"
(49 .5)
2 .46"
(62 .5)
2 .48"
(63 .0)
2 .48"
(63 .0)
3 .04"
(77 .2)
3 .32"
(84 .3)
4 .18"
(106 .2)
—
.87"
(22 .1)
.87"
(22 .1)
—
¾-14
.45"
(11 .4)
.45"
(11 .4)
.64"
(16 .3)
.64"
(16 .3)
.64"
(16 .3)
.82"
(20 .8)
.89"
(22 .6)
1 .02"
(25 .9)
1 .02"
(25 .9)
1 .27"
(32 .3)
1 .39"
(35 .3)
1 .52"
(38 .6)
1 .92"
(48 .8)
1 .99"
(50 .5)
—
.38"
(9 .7)
.45"
(11 .4)
—
3
.42"
(10 .7)
.55"
(14 .0)
.55"
(14 .0)
.55"
(14 .0)
.55"
(14 .0)
.55"
(14 .0)
.70"
(17 .8)
.70"
(17 .8)
.70"
(17 .8)
.73"
(18 .5)
.74"
(18 .8)
.75"
(19 .0)
.78"
(19 .8)
.78"
(19 .8)
—
.46"
(11 .7)
.46"
(11 .7)
—
½-14
.90"
(22 .9)
.90"
(22 .9)
1 .20"
(30 .5)
1 .50"
(38 .1)
1 .20"
(30 .5)
1 .40"
(35 .6)
1 .40"
(35 .6)
1 .60"
(40 .6)
1 .70"
(43 .2)
1 .70"
(43 .2)
1 .70"
(43 .2)
2 .20"
(55 .9)
2 .20"
(55 .9)
2 .70"
(68 .6)
—
.90"
(22 .9)
.90"
(22 .9)
—
2
.88"
(22 .4)
.88"
(22 .4)
1 .13"
(28 .7)
1 .38"
(35 .1)
1 .13"
(28 .7)
1 .38"
(35 .1)
1 .38"
(35 .1)
1 .69"
(42 .9)
.88"
(22 .4)
.88"
(22 .4)
—
½-14
.98"
(24 .9)
.98"
(24 .9)
1 .27"
(32 .3)
1 .55"
(39 .4)
1 .27"
(32 .3)
1 .55"
(39 .4)
1 .55"
(39 .4)
1 .92"
(48 .8)
2 .40"
(61 .0)
2 .40"
(61 .0)
2 .40"
(61 .0)
3 .06"
(77 .7)
3 .06"
(77 .7)
3 .95"
(100 .3)
—
1 .01"
(25 .7)
1 .01"
(25 .7)
—
—
—
—
—
—
—
—
2½-8
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
3-8
7
—
—
—
—
—
—
—
—
—
—
—
—
—
—
3-8
8
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Technical Information
Note: *A/C— Across Corners; A/F—Across Flats.
A
(Overall)
B Ref.
E
F
C
D
T-94
Dimensions shown are approximate and
are subject to change without notice.
www.hubbell-wiring.com
Dimensions in Inches (cm)
Technical Information
Cord Connectors
45° Hubbell Connectors
F
N.P.T.
Form
½-14
2
¾-14
3
1-11½
4
1½-11½
5
1½-11½
5
Aluminum Inches (mm)
A
B
C
D
E
G
Throat Across Across
Ref.
Ref.
Dia.
Corners Flats
Dia.
Zinc Plated Steel Inches (mm)
A
B
C
D
Throat
Ref.
Ref.
Dia.
E
Across
Corners
G
Across Across Across
Flats
Corners Flats
2 .00"
(50 .8)
2 .30"
(58 .4)
2 .60"
(66 .0)
3 .90"
(99 .1)
3 .90"
(99 .1)
1 .97" 1 .90" .55" .57"
(50 .0) (48 .3) (14 .0) (14 .4)
—
—
—
—
1 .24"
(31 .5)
—
1 .06"
(26 .9)
—
1 .27"
(32 .3)
—
1 .13"
(28 .6)
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
1 .90"
(48 .3)
2 .50"
(65 .3)
2 .80"
(71 .1)
3 .90"
(9 .91)
3 .90"
(99 .1)
.55"
(14 .0)
.56"
(14 .2)
.70"
(17 .8)
.74"
(18 .8)
.74"
(18 .8)
.56"
(14 .2)
.75"
(19 .0)
1 .00"
(25 .4)
1 .25"
(31 .7)
1 .50"
(38 .1)
1 .27"
(32 .3)
1 .48"
(37 .6)
1 .69"
(42 .9)
2 .45"
(62 .2)
2 .45"
(62 .2)
1 .10"
(27 .9)
1 .28"
(32 .5)
1 .50"
(38 .1)
2 .13"
(54 .0)
2 .13"
(54 .0)
1 .13"
(28 .6)
1 .38"
(34 .9)
1 .75"
(44 .4)
2 .31"
(58 .7)
2 .31"
(58 .7)
Kellems® Wire Management Products
Kellems® Wire Management Products
90° Hubbell Connectors
F
N.P.T.
Form
³⁄₈-18
1
½-14
2
¾-14
3
1-11½
4
1¼-11½
5
1½-11½
5
2-11½
6
Aluminum Inches (mm)
A
B
C
D
E
G
Throat Across Across
Ref.
Dia.
Corners Flats
Dia.
Zinc Plated Steel Inches (mm)
A
B
C
D
Throat
Ref.
Dia.
E
Across
Corners
G
Across Across Across
Flats
Corners Flats
1 .27"
(32 .3)
1 .56"
(39 .6)
1 .79"
(45 .5)
2 .08"
(52 .8)
3 .18"
(80 .8)
3 .18"
(80 .8)
3 .51"
(89 .2)
—
—
—
—
—
—
—
—
1 .65"
(41 .9)
1 .88"
(47 .8)
2 .16"
(54 .9)
—
2 .38"
(60 .5)
2 .90"
(73 .7)
3 .20"
(81 .3)
—
.55"
(14 .0)
.56"
(14 .2)
.70"
(17 .8)
—
.55"
(13 .8)
.77"
(19 .4)
1 .00"
(25 .4)
—
1 .29"
(32 .8)
1 .52"
(38 .6)
1 .72"
(43 .7)
—
1 .13"
(28 .7)
1 .33"
(33 .8)
1 .50"
(38 .1)
—
1 .27"
(32 .3)
1 .55"
(39 .2)
1 .92"
(48 .8)
—
1 .13"
(28 .6)
1 .38"
(34 .9)
1 .69"
(42 .8)
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
2 .00"
(50 .8)
2 .30"
(58 .4)
2 .80"
(71 .1)
3 .20"
(81 .3)
4 .30"
(109 .2)
4 .30"
(109 .2)
5 .50"
(139 .7)
.46"
(11 .7)
.50"
(12 .7)
.56"
(14 .2)
.70"
(17 .8)
.73"
(18 .5)
.75"
(19 .2)
.80"
(20 .3)
.44"
(11 .2)
.55"
(13 .9)
.77"
(19 .4)
1 .00"
(25 .4)
1 .26"
(32 .0)
1 .50"
(38 .1)
1 .92"
(48 .8)
1 .15"
(29 .2)
1 .30"
(33 .0)
1 .49"
(37 .8)
1 .70"
(43 .2)
2 .47"
(62 .7)
2 .47"
(62 .7)
2 .98"
(75 .7)
1 .10"
(27 .9)
1 .13"
(28 .7)
1 .31"
(33 .3)
1 .50"
(38 .1)
2 .15"
(54 .6)
2 .15"
(54 .6)
2 .78"
(70 .6)
.88"
(22 .2)
1 .13"
(28 .6)
1 .38"
(34 .9)
1 .75"
(44 .4)
2 .31"
(58 .7)
2 .31"
(58 .7)
3 .00"
(76 .2)
90° Hubbell Connectors
Nylon Inches (mm)
A
B
C
F
N.P.T.
Form
³⁄₈-18
½-14
1
2
¾-14
3
1-11½
4
Ref.
—
2 .50"
(63 .5)
2 .81"
(71 .4)
3 .30"
(83 .8)
—
.55"
(14 .0)
.56"
(14 .2)
.70"
(17 .8)
—
.58"
(14 .6)
.77"
(19 .4)
1 .01"
(25 .7)
G
—
1 .23"
(31 .2)
1 .42"
(36 .1)
1 .82"
(46 .2)
—
1 .12"
(28 .2)
1 .29"
(32 .8)
1 .60"
(40 .6)
—
1 .32"
(33 .4)
1 .56"
(39 .6)
1 .88"
(47 .6)
Technical Information
—
1 .41"
(35 .8)
1 .65"
(41 .9)
1 .99"
(50 .5)
D
E
G
Throat Across Across
Dia.
Corners Flats
Dia.
B Ref.
B Ref.
G
A
Ref.
A
E
E
C
F
Dimensions shown are approximate and
are subject to change without notice.
D
Dimensions in Inches (cm)
www.hubbell-wiring.com
C
F
D
T-95
Kellems® Wire Management Products
Kellems® Wire Management Products
Technical Information
Cord Connectors
A
(Overall)
Female Hubbell Connectors
B Ref.
E
Aluminum
Inches (mm)
F
A
B
Dia.
Ref.
A
(Overall)
F
C
E
Across
Corners
Across
Flats
Form
³⁄₈-18
1
.88"
(22 .4)
1 .40"
(35 .6)
.56"
(14 .2)
.44"
(11 .2)
.94"
(23 .9)
.81"
(20 .6)
½-14
2
1 .13"
(28 .7)
1 .80"
(45 .7)
.56"
(14 .2)
.63"
(16 .0)
1 .15"
(29 .2)
1 .00"
(25 .4)
¾-14
2
1 .13"
(28 .7)
2 .10"
(53 .3)
.75"
(19 .0)
.63"
(16 .0)
1 .44"
(36 .6)
1 .25"
(31 .7)
1-11½
4
1 .75"
(44 .5)
2 .30"
(58 .4)
.88"
(22 .4)
1 .10"
(27 .9)
1 .88"
(47 .8)
1 .63"
(41 .4)
1¼-11½
5
2 .31"
(58 .7)
2 .80"
(71 .1)
.95"
(24 .1)
1 .43"
(36 .3)
2 .64"
(67 .1)
2 .29"
(58 .2)
1½-11½
5
2 .31"
(58 .7)
2 .80"
(71 .1)
.95"
(24 .1)
1 .43"
(36 .3)
2 .64"
(67 .1)
2 .29"
(58 .2)
B Ref.
E
D
Throat
Dia.
N.P.T.
D
C (N.P.T. Thread Depth)
C
D
Underground Feeder Connectors
Aluminum Inches (mm)
F
A
B
C
Nylon Inches (mm)
D
E
A
B
C
Thrt.
N.P.T. Form Dia.
Ref.
Dia.
Zinc-Plated Steel Inches (mm)
D
E
A
B
C
Thrt.
A/C*
A/F*
Dia.
Ref.
Dia.
D
E
Thrt.
A/C*
A/F*
A/C*
A/F*
Ref.
Dia.
A/C*
A/F*
½-14
2
1 .13" 1 .10" .55" .64" 1 .10" 1 .00" 1 .32" 1 .50" .55" .58" 1 .25" 1 .13" 1 .27" 1 .13" 1 .20" .55" .64" 1 .11" 1 .00"
(28 .7) (27 .9) (14 .0) (16 .3) (27 .9) (25 .4) (33 .5) (38 .1) (14 .0) (14 .7) (31 .7) (28 .7) (32 .3) (28 .7) (30 .5) (14 .0) (16 .3) (28 .2) (25 .4)
¾-14
2
1 .13" 1 .10" .55" .64" 1 .29" 1 .13" —
(28 .7) (27 .9) (14 .0) (16 .3) (32 .8) (25 .4)
¾-14
3
1 .13" 1 .50" .55" .82" 1 .40" 1 .25" 1 .56" 1 .60" .56" .77" 1 .44" 1 .31" 1 .55" 1 .38" 1 .40" .56" .82" 1 .40" 1 .25"
(28 .7) (38 .1) (14 .0) (20 .8) (35 .6) (31 .7) (39 .6) (40 .6) (14 .2) (19 .6) (36 .6) (33 .3) (39 .4) (35 .1) (35 .6) (14 .2) (20 .8) (35 .6) (31 .7)
—
—
—
—
—
1 .27" 1 .13" 1 .20" .55" .64" 1 .29" 1 .13"
(32 .3) (28 .7) (30 .5) (14 .0) (16 .3) (32 .8) (28 .7)
Note: *A/C - Across Corners; A/F - Across Flats.
Low Profile Non-Metallic N.P.T., PG and Metric Thread Connectors
Nylon Inches (mm)
B
F
D
C
E
Technical Information
SEALING NUT
A
Recommended
knockout size
T-96
Hub Size
A
B
C
D
E
F
³⁄₈ N .P .T .
0 .670" (17 .0)
1 .41" (35 .8)
0 .48" (12 .4)
0 .21" (5 .3)
0 .83" (21 .0)
0 .55" (14 .0)
½ N .P .T .
0 .875" (22 .2)
1 .70" (43 .2)
0 .61" (15 .5)
0 .21" (5 .3)
0 .88" (24 .8)
0 .66" (16 .8)
¾ N .P .T .
1 .068" (27 .1)
2 .00" (50 .8)
0 .62" (15 .7)
0 .25" (6 .3)
1 .30" (33 .0)
0 .85" (21 .6)
1 N .P .T .
1 .375" (35 .0)
2 .41" (61 .2)
0 .76" (19 .3)
0 .30" (7 .6)
1 .73" (43 .9)
1 .05" (26 .7)
PG7
0 .492" (12 .5)
1 .16" (29 .5)
0 .32" (8 .1)
0 .21" (5 .3)
0 .63" (16 .0)
0 .48" (12 .4)
PG9
0 .599" (15 .2)
1 .25" (31 .8)
0 .32" (8 .1)
0 .21" (5 .3)
0 .83" (21 .0)
0 .55" (14 .0)
PG11
0 .733" (18 .6)
1 .48" (37 .6)
0 .38" (9 .7)
0 .21" (5 .3)
0 .94" (23 .9)
0 .70" (17 .8)
PG13 .5
0 .804" (20 .4)
1 .53" (38 .9)
0 .41" (10 .4)
0 .21" (5 .3)
0 .98" (24 .9)
0 .66" (16 .8)
PG16
0 .888" (22 .5)
1 .68" (42 .7)
0 .44" (11 .2)
0 .25" (6 .4)
1 .06" (27 .0)
0 .76" (19 .3)
PG21
1 .15" (28 .3)
1 .89" (48 .0)
0 .52" (13 .2)
0 .25" (6 .4)
1 .30" (33 .0)
.085" (21 .6)
PG29
1 .47" (37 .30)
2 .23" (56 .6)
0 .58" (14 .7)
0 .30" (7 .6)
1 .73" (43 .9)
1 .05" (26 .7)
PG36
1 .85" (47 .0)
2 .39" (60 .7)
0 .47" (11 .9)
0 .31" (7 .9)
2 .05" (52 .7)
1 .19" (30 .2)
M12
0 .473" (12 .0)
1 .16" (29 .5)
0 .32" (8 .1)
0 .21" (5 .3)
0 .63" (16 .0)
0 .49" (12 .4)
M16
0 .630" (16 .0)
1 .25" (31 .8)
0 .32" (8 .1)
0 .21" (5 .3)
0 .83" (21 .0)
0 .55" (14 .0)
M20
0 .787" (20 .0)
1 .53" (38 .9)
0 .41" (10 .4)
0 .21" (5 .3)
0 .98" (24 .9)
0 .66" (16 .8)
M25
0 .985" (25 .0)
1 .89" (48 .0)
0 .52" (13 .2)
0 .25" (6 .3)
1 .30" (33 .0)
0 .85" (21 .6)
M32
1 .260" (32 .0)
2 .23" (56 .6)
0 .58" (14 .7)
0 .30" (7 .6)
1 .73" (43 .9)
1 .05" (26 .7)
M40
1 .575" (40 .0)
2 .39" (60 .7)
0 .48" (12 .2)
0 .30" (7 .6)
2 .05" (52 .1)
1 .19" (30 .2)
www.hubbell-wiring.com
Dimensions in Inches (cm)
Technical Information
Cord Connectors
2 Conductors
Cord Type
SVO,
SV,
SVT
SJ, SJO, SJT, SJTO
Cord Size
#18
#18
#16
#14
#18
#16
#14
#12
#10
#8
Approximate
Diameter
.25"
(6.2)
.31"
(7.8)
.33"
(8.4)
.37"
(9.3)
.38"
(9.7)
.40"
(10.2)
.54"
(13.7)
.62"
(15.6)
.68"
(17.1)
.81"
(20.6)
Black
Black
White
White
Blue
Blue
Brown
Brown
Yellow
Orchid
HC1004
HC1010
HC1016
HC1022
—
HC1032
—
—
—
—
—
—
—
HC1005
HC1011
HC1017
HC1022
—
HC1032
—
—
—
—
—
—
—
HC1005
HC1011
HC1017
HC1022
—
HC1032
—
—
—
—
—
—
—
HC1006
HC1012
HC1018
HC1023
HC1025
HC1033
HC1035
HC1039
—
—
—
—
—
HC1006
HC1012
HC1018
HC1023
HC1025
HC1033
HC1035
HC1039
—
—
—
—
—
—
—
—
HC1024
HC1026
HC1034
HC1036
HC1040
—
—
—
—
—
—
—
—
HC1024
HC1026
HC1034
HC1036
HC1040
—
—
—
—
—
—
—
—
—
HC1027
—
HC1037
HC1041
—
—
—
—
—
—
—
—
—
HC1028
—
HC1038
HC1042
HC1045
HC1050
HC1055
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Color
N.P.T.
Form
S, SO, ST, STO
Catalog Number*
¼
³⁄₈
½
½
½
¾
¾
1
1
1¼
1½
1½
2
2
1
1
1
2
3
2
3
4
5
5
5
6
6
7
HC1004
HC1010
HC1016
HC1022
—
HC1032
—
—
—
—
—
—
—
—
2½
3
7
7
—
—
Kellems® Wire Management Products
Kellems® Wire Management Products
Note: * Must add prefix, see Note 1; suffix, see Note 2, on page T-100.
‡ F5 and larger will not be color coded.
3 Conductors
Cord Type
SVO,
SV,
SVT
SJ, SJO, SJT, SJTO
Cord Size
#18
#18
#16
#14
#18
#16
#14
#12
#10
#8
Approximate
Diameter
.26"
(6.5)
.33"
(8.3)
.35"
(8.9)
.39"
(9.8)
.39"
(9.9)
.42"
(10.7)
.57"
(14.4)
.65"
(16.4)
.71"
(18.0)
.85"
(21.5)
Black
White
White
Blue
Blue
Blue
Brown
Yellow
Yellow
Orchid
HC1005
HC1011
HC1017
HC1022
—
HC1032
—
—
—
—
—
—
—
—
—
—
HC1006
HC1012
HC1018
HC1023
HC1025
HC1033
HC1035
HC1039
—
—
—
—
—
—
—
—
HC1006
HC1012
HC1018
HC1023
HC1025
HC1033
HC1035
HC1039
—
—
—
—
—
—
—
—
HC1006
HC1012
HC1018
HC1023
HC1025
HC1033
HC1035
HC1039
—
—
—
—
—
—
—
—
—
—
—
HC1024
HC1026
HC1034
HC1036
HC1040
—
—
—
—
—
—
—
—
—
—
—
—
HC1027
—
HC1037
HC1041
—
—
—
—
—
—
—
—
—
—
—
—
HC1027
—
HC1037
HC1041
—
—
—
—
—
—
—
—
—
—
—
—
HC1028
—
HC1038
HC1042
HC1045
HC1050
HC1055
—
—
—
—
—
Color
N.P.T.
1
1
1
2
3
2
3
4
5
5
5
6
6
7
7
7
Catalog Number*
HC1004
HC1010
HC1016
HC1022
—
HC1032
—
—
—
—
—
—
—
—
—
—
HC1005
HC1011
HC1017
HC1022
—
HC1032
—
—
—
—
—
—
—
—
—
—
Note: * Must add prefix, see Note 1; suffix, see Note 2, on page T-100.
‡ F5 and larger will not be color coded.
Dimensions in Inches (cm)
www.hubbell-wiring.com
T-97
Technical Information
¼
³⁄₈
½
½
½
¾
¾
1
1
1¼
1½
1½
2
2
2½
3
Form
S, SO, ST, STO
Kellems® Wire Management Products
Kellems® Wire Management Products
Technical Information
Cord Connectors
2 Conductors
Cord Type
SVO,
SV,
SVT
SJ, SJO, SJT, SJTO
Cord Size
#6
#4
#3
#2
#1
#1/0
#2/0
#3/0
#4/0
#250
Approximate
Diameter
.94"
(23.8)
1.08"
(27.4)
1.17"
(29.7)
1.27"
(33.3)
1.44"
(36.6)
1.52"
(38.6)
1.65"
(41.9)
1.77"
(45.0)
1.92"
(48.8)
2.16"
(51.9)
Gray‡
Pink‡
‡
‡
‡
‡
‡
‡
‡
‡
—
—
—
—
—
—
—
—
HC1049
HC1054
HC1059
HC1060
HC1065
—
—
—
—
—
—
—
—
—
—
—
HC1061
HC1066
—
—
—
—
—
—
—
—
—
—
—
HC1062
HC1067
—
—
—
—
—
—
—
—
—
—
—
HC1063
HC1068
—
—
—
—
—
—
—
—
—
—
—
HC1064
HC1069
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
HC1070
HC1076
HC1086
HC1071
HC1077
HC1087
HC1073
HC1079
HC1089
Color
N.P.T.
Form
S, SO, ST, STO
Catalog Number*
¼
³⁄₈
½
½
½
¾
¾
1
1
1¼
1½
1½
2
2
1
1
1
2
3
2
3
4
5
5
5
6
6
7
—
—
—
—
—
—
—
HC1043
HC1046
HC1051
HC1056
—
—
—
—
—
—
—
—
—
—
HC1044
HC1047
HC1052
HC1057
—
—
—
—
—
—
—
—
—
—
—
HC1048
HC1053
HC1058
—
—
—
2½
3
7
7
—
—
—
—
—
—
Note: * Must add prefix, see Note 1; suffix, see Note 2, on page T-100.
‡ F5 and larger will not be color coded.
3 Conductors
CordType
SVO,
SV,
SVT
SJ, SJO, SJT, SJTO
Cord Size
#6
#4
#3
#2
#1
#1/0
#2/0
#3/0
#4/0
#250
Approximate
Diameter
1.00"
(25.4)
1.17"
(29.7)
1.24"
(31.5)
1.34"
(34.0)
1.51"
(38.4)
1.65"
(41.9)
1.75"
(44.5)
1.80"
(48.0)
2.07"
(52.6)
2.39"
(60.7)
Gray‡
‡
‡
‡
‡
‡
‡
‡
‡
‡
—
—
—
—
—
—
—
—
HC1048
HC1053
HC1058
—
—
—
—
—
—
—
—
—
—
—
—
—
HC1049
HC1054
HC1059
HC1060
HC1065
—
—
—
—
—
—
—
—
—
—
—
—
—
—
HC1062
HC1067
—
—
—
—
—
—
—
—
—
—
—
—
—
—
HC1063
HC1068
—
—
—
—
—
—
—
—
—
—
—
—
—
—
HC1064
HC1069
HC1070
HC1076
HC1086
—
—
—
—
—
—
—
—
—
—
—
—
—
HC1071
HC1077
HC1087
—
—
—
—
—
—
—
—
—
—
—
—
—
HC1073
HC1079
HC1089
—
—
—
—
—
—
—
—
—
—
—
—
—
HC1075
HC1081
HC1091
Color
Technical Information
N.P.T.
Form
¼
³⁄₈
½
½
½
¾
¾
1
1
1¼
1½
1½
2
2
2½
3
1
1
1
2
3
2
3
4
5
5
5
6
6
7
7
7
S, SO, ST, STO
Catalog Number*
—
—
—
—
—
—
—
HC1044
HC1047
HC1052
HC1057
—
—
—
—
—
—
—
—
—
—
—
—
—
HC1048
HC1053
HC1058
—
—
—
—
—
Note: * Must add prefix, see Note 1; suffix, see Note 2, on page T-100.
‡ F5 and larger will not be color coded.
T-98
www.hubbell-wiring.com
Dimensions in Inches (cm)
Technical Information
Cord Connectors
4 Conductors
Cord Type
SJ, SJO,
SJT,
SJTO
Cord Size
#18
#16
#14
#18
#16
#14
#12
#10
#8
Approximate
Diameter
.36"
(9.0)
.39"
(9.8)
.43"
(10.8)
.42"
(10.7)
.45"
(11.4)
.61"
(15.5)
.70"
(17.8)
.77"
(19.4)
.97"
(24.6)
Color
White
Blue
Blue
Blue
Blue
Brown
Yellow
Orchid
Gray‡
N.P.T.
Form
S, SO, ST, STO
Catalog Number*
¼
1
HC1005
HC1006
HC1006
HC1006
—
—
—
—
—
³⁄₈
1
HC1011
HC1012
HC1012
HC1012
—
—
—
—
—
½
1
HC1017
HC1018
HC1018
HC1018
—
—
—
—
—
½
2
HC1022
HC1023
HC1023
HC1023
HC1023
HC1024
—
—
—
½
3
—
HC1025
HC1025
HC1025
HC1025
HC1026
HC1027
HC1028
—
¾
2
—
HC1033
HC1033
HC1033
HC1033
HC1034
—
—
—
¾
3
—
HC1035
HC1035
HC1035
HC1035
HC1036
HC1037
HC1038
1
4
—
HC1039
HC1039
HC1039
HC1039
HC1040
HC1041
HC1042
HC1043
1
5
—
—
—
—
—
—
—
—
HC1046
1¼
5
—
—
—
—
—
—
—
—
HC1051
1½
5
—
—
—
—
—
—
—
—
HC1056
1½
6
—
—
—
—
—
—
—
—
—
2
6
—
—
—
—
—
—
—
—
—
2
7
—
—
—
—
—
—
—
—
—
2½
7
—
—
—
—
—
—
—
—
—
3
7
—
—
—
—
—
—
—
—
—
Kellems® Wire Management Products
Kellems® Wire Management Products
Note: * Must add prefix, see Note 1; suffix, see Note 2, on page T-100.
‡ F5 and larger will not be color coded.
5 Conductors
Cord Type
S, SO, ST, STO
Cord Size
#18
#16
#14
#12
#10
#8
#6
Approximate
Diameter
.50"
(12.7)
.54"
(13.7)
.70"
(17.7)
.76"
(19.3)
.83"
(21.1)
1.06"
(26.9)
1.18"
(30.0)
Color
Blue
Brown
Yellow
Orchid‡
Orchid‡
Pink‡
‡
N.P.T.
Form
Catalog Number*
2
HC1023
HC1024
—
—
—
—
—
½
3
HC1025
HC1026
HC1027
HC1028
HC1028
—
—
¾
2
HC1033
HC1034
—
—
—
—
—
¾
3
HC1035
HC1036
HC1037
HC1038
HC1038
—
—
1
4
HC1039
HC1040
HC1041
HC1042
HC1042
HC1044
—
1
5
—
—
—
HC1045
HC1045
HC1047
HC1048
1¼
5
—
—
—
HC1050
HC1050
HC1052
HC1053
1½
5
—
—
—
HC1055
HC1055
HC1057
HC1058
Technical Information
½
Note * Must add prefix, see Note 1; suffix, see Note 2, on page T-100.
‡ F5 and larger will not be color coded.
Dimensions in Inches (cm)
www.hubbell-wiring.com
T-99
Kellems® Wire Management Products
Kellems® Wire Management Products
Technical Information
Cord Connectors
4 Conductors
Cord Type
SJ, SJO,
SJT,
SJTO
Cord Size
#6
#4
#3
#2
#1
#1/0
#2/0
#3/0
#4/0
Approximate
Diameter
.94"
(23.8)
1.08"
(27.4)
1.17"
(29.7)
1.27"
(33.3)
1.44"
(36.6)
1.52"
(38.6)
1.65"
(41.9)
1.77"
(45.0)
1.92"
(48.8)
Color
Pink‡
‡
‡
‡
‡
‡
‡
‡
‡
N.P.T.
Form
S, SO, ST, STO
Catalog Number*
¼
1
—
—
—
—
—
—
—
—
—
³⁄₈
1
—
—
—
—
—
—
—
—
—
½
1
—
—
—
—
—
—
—
—
—
½
2
—
—
—
—
—
—
—
—
—
½
3
—
—
—
—
—
—
—
—
—
¾
2
—
—
—
—
—
—
—
—
—
¾
3
—
—
—
—
—
—
—
—
—
1
4
HC1044
—
—
—
—
—
—
—
—
1
5
HC1047
HC1049
HC1049
—
—
—
—
—
—
1¼
5
HC1052
HC1054
HC1054
—
—
—
—
—
—
1½
5
HC1057
HC1059
HC1059
—
—
—
—
—
—
1½
6
—
HC1060
HC1060
HC1061
HC1063
HC1064
—
—
—
2
6
—
HC1064
HC1065
HC1066
HC1068
HC1069
—
—
—
2
7
—
—
—
—
—
HC1070
HC1071
HC1073
HC1074
2½
7
—
—
—
—
—
HC1076
HC1077
HC1079
HC1080
3
7
—
—
—
—
—
HC1086
HC1087
HC1089
HC1090
Note: * Must add prefix, see Note 1; suffix, see Note 2, below.
‡ F5 and larger will not be color coded.
Note:
Technical Information
1. Add the proper prefix to the HC number to identify
the type of connector desired:
SHC = Straight Hubbell Connector
NHC = 90° Hubbell Connector
FHC = Female Hubbell Connector
VHC = 45° Hubbell Connector
2. Add the proper suffix to identify material desired:
Aluminum = No suffix
Zinc-Plated Steel = ZP
Corrosion Resistant Nylon = CR
Stainless Steel = SS
T-100
3. This chart is a general guide to assist in the selection
of Hubbell Cord Connectors for various cord sizes .
The Hubbell Cord Connector catalog numbers selected,
have been inserted into spaces which in our judgment
represent the best cord connector which will fit the
listed cord size .
The diameters of the cords are approximate and may
vary depending on the manufacturer . It is suggested
that the appropriate cord manufacturer’s dimension
chart be consulted for exact dimensions .
4. Cable jacket may have to be stripped to allow
conductors to pass through connector body .
www.hubbell-wiring.com
Dimensions in Inches (cm)
Technical Information
Locknuts and Sealing O-Rings
N.P.T. Thread Locknuts
Zinc-Plated Steel
N.P.T.
Hub
Size
A
Inside Dia.
inches (mm)
B
Outside Dia.
inches (mm)
C
Thk.
inches (mm)
Steel
Catalog Number
½
¾
1
1¼
1½
½"-14
¾"-14
1"-11½
1¼"-11½
1½"-11½
1 .14"
1 .43"
1 .77"
2 .28"
2 .60"
.09"
.11"
.13"
.13"
.13"
00322001LPK50
00322002LPK50
00322003LPK50
00322004LPK50
00322005LPK50
(29 .0)
(36 .3)
(45 .0)
(57 .9)
(66 .0)
(2 .3)
(2 .8)
(3 .3)
(3 .3)
(3 .3)
B
Maximum
Diameter
C
Minimum
Thk.
A
Thread Size
(N.P.S.)
Metal Clad Sealing O-Rings – Sizes ½ - 4
Zinc-Plated Steel with Neoprene Ring
N.P.T.
Hub
Size
A
Inside Dia.
inches (mm)
B
Outside Dia.
inches (mm)
C
Thk.
inches (mm)
Catalog Number
½
¾
1
1¼
1½
2
.80"
1 .00"
1 .25"
1 .61"
1 .84"
2 .31"
1 .08"
1 .34"
1 .63"
2 .00"
2 .36"
2 .83"
.16"
.16"
.16"
.16"
.16"
.16"
20509001
20509002
20509003
20509004
20509005
20509006
(20 .3)
(25 .4)
(31 .6)
(40 .9)
(46 .7)
(58 .7)
(27 .4)
(34 .0)
(41 .4)
(50 .8)
(59 .9)
(71 .9)
Chrome Plated Steel with Neoprene Ring
2½
2 .91" (73 .9)
3 .44" (87 .4)
3
3 .52" (89 .4)
4 .08" (103 .6)
(3 .2)
(3 .2)
(3 .2)
(3 .2)
(3 .2)
(3 .2)
A
Kellems® Wire Management Products
Kellems® Wire Management Products
B
C
.24"
.24"
(6 .1)
(6 .1)
20509007
20509008
Nylon PG Thread Locknuts
PG Thread
Size
A
inches
(mm)
B
inches (mm)
C
inches (mm)
Catalog Number
PG7
PG9
PG11
PG13 .5
PG16
PG21
PG29
PG36
.75"
.86"
.94"
1 .06"
1 .18"
1 .41"
1 .81"
2 .24"
(19 .1)
(21 .8)
(23 .9)
(26 .9)
(30 .0)
(35 .8)
(46 .0)
(56 .9)
.80"
.91"
1 .03"
1 .14"
1 .30"
1 .54"
2 .00"
2 .50"
.22"
.22"
.22"
.24"
.25"
.25"
.25"
.25"
LNP7BPK100
LNP9BPK100
LNP11BPK100
LNP13BPK100
LNP16BPK100
LNP21BPK100
LNP29BPK25
LNP36BPK25
(20 .3)
(23 .2)
(26 .2)
(29 .0)
(33 .0)
(39 .1)
(50 .8)
(63 .5)
(5 .6)
(5 .6)
(5 .6)
(6 .1)
(6 .1)
(6 .1)
(6 .1)
(6 .1)
B
A
C
PG Thread
Size
A
inches
(mm)
B
inches (mm)
C
inches (mm)
Catalog Number
M12
M16
M20
M25
M32
M40
.75"
.87"
1 .06"
1 .38"
1 .61"
1 .97"
(19 .1)
(22 .09)
(27 .0)
(35 .1)
(40 .9)
(50 .0)
.82"
.98"
1 .18"
1 .54"
1 .80"
2 .18"
.22"
.22"
.25"
.28"
.28"
.28"
LNM12BPK100
LNM16BPK100
LNM20BPK100
LNM25BPK100
LNM32BPK100
LNM40BPK100
(20 .8)
(25 .0)
(30 .0)
(39 .1)
(45 .7)
(55 .4)
(5 .6)
(5 .6)
(6 .4)
(7 .1)
(7 .1)
(7 .1)
Technical Information
Nylon Metric Thread Locknuts
Dimensions shown are approximate and
are subject to change without notice.
Dimensions in Inches (cm)
www.hubbell-wiring.com
T-101
Kellems® Wire Management Products
Kellems® Wire Management Products
Technical Information
Hubbell Juniors® Miniature Nylon Cord Connectors
Hubbell Juniors®
Material
Nylon (connectors and
Neoprene (bushings)
Operating Temperature Range
GOTCHA®
rings)
-40°F to +225°F (-40°C to +107°C)
-30°F to +240°F (-34°C to +115°C)
Due to the limiting factors of nylon and neoprene, any complete liquidtight Hubbell Junior will continuously perform in the range
of -30°F to +225°F (-34°C to +107°C).
Snap-In continuously performs -40°F to +225°F (-40°C to +107°C).
Flammability
Hubbell Juniors have a UL 94V-2 rating .
Certifications
Product
Agency
Liquidtight and Liquidtight with Spiral
UL Listed .
CSA Certified .
UL Recognized .
CSA Certified .
Snap-In
Knockout Holes
¼
³⁄₈
½
.54"- .57" (13 .7-14 .5)
.67"- .70" (17 .0-17 .8)
.86"- .91" (21 .8-23 .1)
Technical Information
N.P.T.
Hub Size
Knockout Hole
Recommended
Min. to Max.
inches
(mm)
Dimensions shown are approximate and
are subject to change without notice .
T-102
www.hubbell-wiring.com
Dimensions in Inches (cm)
Technical Information
Hubbell Juniors® Miniature Nylon Cord Connectors
Snap-In
Diameter
Range
Inches
(mm)
For
Chas.
Thk.
(Max.)
Inches
(mm)
Required
Hole Size
A
B
Inches
Inches
(mm)
(mm)
Dimensional
Specifications
C
D
Inches
Inches
(mm)
(mm)
E
Inches
(mm)
F
Inches
(mm)
G
Inches
(mm)
.22"- .27"
(5 .6-6 .9)
.10"
(2 .5)
.50"
(12 .7)
.45"
(11 .4)
.28"
(7 .1)
.28"
(7 .1)
.54"
(13 .7)
.12"
(3 .0)
1 .84"
(44 .2)
.28"- .32"
(7 .1-8 .1)
.10"
(2 .5)
.50"
(12 .7)
.47"
(11 .9)
.28"
(7 .1)
.33"
(8 .4)
.59"
(15 .0)
.12"
(3 .0)
1 .84"
(44 .2)
.30"- .36"
(7 .6-9 .1)
.13"
(3 .3)
.63"
(16 .0)
.55"
(14 .0)
.36"
(9 .1)
.37"
(9 .4)
.65"
(16 .5)
.14"
(3 .6)
2 .18"
(55 .4)
.32"- .43"
(8 .1-10 .9)
.13"
(3 .3)
.75"
(19 .0)
.66"
(16 .8)
.45"
(11 .4)
.44"
(11 .2)
.75"
(19 .1)
.14"
(3 .6)
2 .60"
(66 .0)
G
C
D
F
E
A
Chassis
Thickness
Max
B
Kellems® Wire Management Products
Kellems® Wire Management Products
B
Liquidtight
F
A
B
C
N.P.T.
Dia.
Inches
(mm)
Ref.
Inches
(mm)
¼-18
.65"
(16 .5)
³⁄₈-18
½-14
E
C
Inches
(mm)
D
Throat
Dia.
Inches
(mm)
Across
Corners
Inches
(mm)
1 .30"
(33 .0)
.40"
(10 .2)
.29"
(7 .4)
.65"
(16 .5)
.60"
(15 .2)
.81"
(20 .6)
1 .44"
(36 .6)
.41"
(10 .4)
.36"
(9 .1)
.81"
(20 .6)
.75"
(19 .1)
1 .00"
(25 .4)
1 .56"
(39 .6)
.46"
(11 .7)
.45"
(11 .4)
.99"
(25 .1)
.92"
(23 .4)
Across
Flats
Inches
(mm)
D
A
F
E
Liquidtight with Spiral
A
B
C
E
Inches
(mm)
D
Throat
Dia.
Inches
(mm)
Inches
(mm)
F
Across
Corners
Inches
(mm)
N.P.T.
Dia.
Inches
(mm)
Ref.
Inches
(mm)
Across
Flats
Inches
(mm)
¼-18
.65"
(16 .5)
2 .55"
(64 .8)
.40"
(10 .2)
.29"
(7 .4)
.27"
(6 .9)
.65"
(16 .5)
.60"
(15 .2)
³⁄₈-18
.81"
(20 .6)
3 .10"
(78 .7)
.41"
(10 .4)
.36"
(9 .1)
.35"
(8 .9)
.81"
(20 .6)
.75"
(19 .1)
½-14
1 .00"
(25 .4)
3 .72"
(94 .5)
.46"
(11 .7)
.45"
(11 .4)
.45"
(11 .4)
.99"
(25 .1)
.92"
(23 .4)
B
A
C
E
D
G
F
Dimensions shown are approximate and
are subject to change without notice .
Dimensions in Inches (cm)
www.hubbell-wiring.com
T-103
Technical Information
G
Kellems® Wire Management Products
Kellems® Wire Management Products
PolyTuff® I Non-Metallic Liquidtight Conduit
Features and Benefits
PolyTuff® I Conduit–Gray
Rigid PVC core bonded to flexible PVC jacket
All nonmetallic construction ends metal fatigue and
separation problems
UL Listed and CSA Certified
PolyTuff® I Non-Metallic Liquidtight Conduit
Cuts cleanly with a knife or PVC cutter so there
are no jagged metal edges
IP66
SUITABILITY
PolyTuff® I Conduit
Trade Size (metric designator)
Feet (m)
Catalog Number
³⁄₈ (12)
100 (30 .5)
G1038
½ (16)
100 (30 .5)
G1050
¾ (21)
100 (30 .5)
G1075
1 (27)
100 (30 .5)
G1100
1¼ (35)
100 (30 .5)
G1125
1½ (41)
50 (15 .2)
G1150
2 (53)
50 (15 .2)
G1200
Note: See pages T-68, T-69, T-107 and T-109 for approved fittings.
See pages T-110 to T-111 for additional technical data and dimensional drawings.
T-104
www.hubbell-wiring.com
Dimensions in Inches (cm)
Kellems® Wire Management Products
Kellems® Wire Management Products
PolyTuff® II Non-Metallic Liquidtight Tubing
Features and Benefits
PolyTuff® II Tubing–Black
PVC core with corrugated walls bonded to PVC jacket
Handles twists, turns, bends, switchbacks and straightaways with ease
All nonmetallic construction ends fatigue and
separation problems
Can be cut with a knife or PVC cutters
UL Recognized and CSA Certified
PolyTuff® II Non-Metallic Liquidtight Tubing
IP66
SUITABILITY
PolyTuff® II Tubing
Trade Size (metric designator)
Feet (m)
Catalog Number
¼ (10)
100 (30 .5)
B2025
³⁄₈ (12)
100 (30 .5)
B2038
½ (16)
100 (30 .5)
B2050
¾ (21)
100 (30 .5)
B2075
1 (27)
100 (30 .5)
B2100
1¼ (35)
100 (30 .5)
B2125
1½ (41)
50 (15 .2)
B2150
2 (53)
50 (15 .2)
B2200
Note: See page T-107 for approved fittings.
See pages T-110 to T-111 for additional technical data and dimensional drawings.
Dimensions in Inches (cm)
www.hubbell-wiring.com
T-105
Kellems® Wire Management Products
PolyTuff® Non-Metallic Liquidtight Fittings
Kellems® Wire Management Products
PolyTuff® Non-Metallic Liquidtight Fittings
Features and Benefits
Nylon two-piece swivel body enables
fitting to twist from 0° to 90°
Non-integral ferrule provides conduit seal
and superior pullout protection
Neoprene O-ring provides
liquidtight seal at hub or enclosure
Nylon compression nut
has a tapered dome to
tighten ferrule onto
conduit
T-106
Nylon locknut fastens connector
securely to enclosure and provides
superior corrosion resistance
www.hubbell-wiring.com
Dimensions in Inches (cm)
PolyTuff® Non-Metallic Liquidtight Fittings
UL Listed to Type
4X, 12 and 13
Straight with Male Non-Metallic Liquidtight Fittings
Trade
Size (metric designator)
Black
Catalog Number
Gray
Catalog Number
¼ (6)
³⁄₈ (9)
½ (13)
¾ (19)
1 (25)
F2025
P038NBKA
P050NBKA
P075NBKA
P100NBKA
—
P038NGYA
P050NGYA
P075NGYA
P100NGYA
1¼ (32)
1½ (38)
2 (51)
P125NBK
P150NBK
P200NBK
P125NGY
P150NGY
P200NGY
P075NGYA
Note: Fittings are to be used with PolyTuff I and PolyTuff II.
See page T-113 for additional technical data and dimensional drawings.
³⁄₈" Liquidtight conduit fitting have ½ N.P.T. male threads.
Kellems® Wire Management Products
Kellems® Wire Management Products
P125NGY
SwivelLok® Multi-Position with Male Non-Metallic Liquidtight Fittings
Trade
Size (metric designator)
Black
Catalog Number
Gray
Catalog Number
³⁄₈ (9)
½ (13)
¾ (19)
1 (25)
PS0389NBK
PS0509NBK
PS0759NBK
PS1009NBK
PS0389NGY
PS0509NGY
PS0759NGY
PS1009NGY
Note: Fittings are to be used with PolyTuff I and PolyTuff II.
See page T-113 for additional technical data and dimensional drawings.
³⁄₈" Liquidtight conduit fitting have ½ N.P.T. male threads.
PS0509NGY - SwivelLok®
PolyTuff® Non-Metallic Liquidtight Fittings
Fixed 90°Fittings for Non-Metallic Conduit
Trade
Size (metric designator)
Black
Catalog Number
Gray
Catalog Number
¼ (6)
³⁄₈ (9)
½ (13)
¾ (19)
1 (25)
1¼ (32)
F20259
P0389NBK
P0509NBK
P0759NBK
P1009NBK
P1259NBK
—
P0389NGY
P0509NGY
P0759NGY
P1009NGY
P1259NGY
Note: Fittings are to be used with PolyTuff I and PolyTuff II.
See page T-113 for additional technical data and dimensional drawings.
³⁄₈⁄"⁄ Liquidtight conduit fitting have ½ N.P.T. male threads.
P1259NGY
SwivelLok® Flexible Conduit Kit
Trade Size (metric designator)
Fitting and Conduit
Catalog Number
½ (13)
¾ (19)
2 PS0509NGY, 6' G1050
2 PS0759NGY, 6' G1075
PS05GYKIT
PS07GYKIT
Note: See page T-113 for additional technical data and dimensional drawings.
PS05GYKIT
Dimensions in Inches (cm)
www.hubbell-wiring.com
T-107
Kellems® Wire Management Products
Kellems® Wire Management Products
Metallic Liquidtight Conduit Fittings
Features and Benefits
Hexagonal, screw-machined steel thru 1", and
malleable iron on larger sizes . Nut compresses
gland-ring onto conduit
Metallic Liquidtight Conduit Fittings
Split, nylon, gland-ring compresses
conduit onto ferrule
Non-integral, reusable steel,
ferrule is easily installed, to
seal conduit
Threaded one-piece steel body
Tapered, machined threads fasten securely and provide
additional liquidtight sealing
Optional insulated and non-insulated throat
Nylon gasket provides liquidtight seal at hub
Locknut has hardened steel tangs to grip securely
T-108
www.hubbell-wiring.com
Dimensions in Inches (cm)
Metallic Liquidtight Conduit Fittings
Straight Conduit Fitting
Trade Size (metric designator)
Insulated
Non-Insulated
³⁄₈ (9)
½ (13)
¾ (19)
1 (25)
H0381
H0501
H0751
H1001
H038
H050
H075
H100
1¼ (32)
1½ (38)
2 (51)
2½ (63)
H1251
H1501
H2001
H2501
H125
H150
H200
H250
3 (76)
3½ (89)
4 (102)
H3001
H3501
H4001
H300
H350
H400
Straight with Male
Hubbell Conduit Fitting
H050
Note: ³⁄₈" Liquidtight conduit fitting have ½ N.P.T. male threads.
For use with Liquidtight Metal conduit and PolyTuff I Non-Metallic conduit.
See page T-114 for additional technical data.
Kellems® Wire Management Products
Kellems® Wire Management Products
45° Conduit Fitting
Trade Size (metric designator)
Insulated
Non-Insulated
³⁄₈ (9)
½ (13)
¾ (19)
1 (25)
H03841
H05041
H07541
H10041
H0384
H0504
H0754
H1004
1¼ (32)
1½ (38)
2 (51)
H12541
H15041
H20041
H1254
H1504
H2004
Note: ³⁄₈" Liquidtight conduit fitting have ½ N.P.T. male threads.
For use with Liquidtight Metal conduit and PolyTuff I Non-Metallic conduit.
See page T-114 for additional technical data.
45° Angle with Male
Hubbell Conduit Fitting
H0504
90° Conduit Fitting
Insulated
Non-Insulated
³⁄₈ (9)
½ (13)
¾ (19)
1 (25)
H03891
H05091
H07591
H10091
H0389
H0509
H0759
H1009
1¼ (32)
1½ (38)
2 (51)
2½ (63)
3 (76)
4 (102)
H12591
H15091
H20091
H25091
H30091
H40091
H1259
H1509
H2009
H2509
H3009
H4009
Note: ³⁄₈" Liquidtight conduit fitting have ½ N.P.T. male threads.
For use with Liquidtight Metal conduit and PolyTuff I Non-Metallic conduit.
See page T-114 for additional technical data.
Dimensions in Inches (cm)
www.hubbell-wiring.com
90° Angle with Male
Hubbell Conduit Fitting
H0509
T-109
Metallic Liquidtight Conduit Fittings
Trade Size (metric designator)
Kellems® Wire Management Products
Kellems® Wire Management Products
Technical Information
Non-Metallic Liquidtight Conduit and Tubing
PolyTuff I Conduit
Operating Temperature Range
Wet environment
Oil environment
Dry environment
0°F to +140°F (-18°C to +60°C) .
0°F to +158°F (-18°C to +70°C) .
0°F to +176°F (-18°C to +80°C) .
Certifications
UL Listed
UL Standard 1660 .
Sunlight resistant approved for outdoor use, direct burial .
Meets requirements of NEC .
CSA Certified
Voltage Rating
Maximum
600V .
Material
Conduit
Co-extruded rigid and flexible PVC .
PolyTuff II Tubing
Operating Temperature Range
Operating environment
0°F to +140°F (-18°C to +60°C) .
Certifications
UL Recognized
CSA Certified
Voltage Rating
Maximum
Same as wire insulation rating .
Material
Tubing
Co-extruded rigid and flexible PVC .
Technical Information
PolyTuff I Conduit
PolyTuff II Tubing
Trade Size
(metric
designator)
Conduit ID/OD
Inches
(mm)
Bend Radius
Inches (mm)
³⁄₈ (12)
½ (16)
¾ (21)
1 (27)
1¼ (35)
1½ (41)
2 (53)
.49"/ .70"
.63"/ .83"
.83"/1 .04"
1 .05"/1 .30"
1 .40"/1 .65"
1 .59"/1 .88"
2 .03"/2 .36"
2 .00"
3 .00"
4 .00"
5 .00"
6 .30"
7 .50"
10 .00"
T-110
(12 .6/17 .8)
(16 .1/21 .1)
(21 .1/26 .4)
(26 .0/33 .1)
(35 .4/41 .8)
(40 .3/47 .8)
(51 .6/59 .9)
(50 .8)
(76 .2)
(101 .6)
(217 .0)
(158 .8)
(190 .5)
(254 .0)
Trade Size
(metric
designator)
Conduit ID/OD
Inches
(mm)
Bend Radius
Inches (mm)
¼ (10)
³⁄₈ (12)
½ (16)
¾ (21)
1 (27)
1¼ (35)
1½ (41)
2 (53)
.36"/ .57"
.49"/ .70"
.63"/ .83"
.83"/1 .04"
1 .05"/1 .30"
1 .40"/1 .65"
1 .59"/1 .88"
2 .03"/2 .36"
1 .50"
2 .00"
2 .00"
3 .00"
3 .00"
5 .00"
5 .00"
5 .00"
www.hubbell-wiring.com
(9 .3/14 .5)
(12 .6/17 .8)
(16 .1/21 .1)
(21 .1/26 .4)
(26 .0/33 .1)
(35 .4/41 .8)
(40 .3/47 .8)
(51 .6/59 .9)
(38 .1)
(50 .8)
(50 .8)
(76 .2)
(76 .2)
(127 .0)
(127 .0)
(127 .0)
Dimensions in Inches (cm)
Technical Information
Non-Metallic Liquidtight Conduit and Tubing
PolyTuff I and II Conduit/Tubing; PVC Chemical Resistance
Chemical
Conc*
Temp.
70°F 150°F
21°C 66°C
Temp.
Conc* 70°F 150°F
21°C 66°C
Chemical
Chemical
Temp.
Conc* 70°F 150°F
21°C 66°C
D
B
C
D
A
C
D
C
D
D
B
C
Coconut Oil
Corn Oil
Cottonseed Oil
Creosote
Cresol
Crysylic Acid
C
A
C
D
C
D
D
B
D
D
D
D
Lubricating Oils
Magnesium Chloride
Magnesium Hydroxide
Magnesium Sulfate
Malathion 50 in Aromatics
Malic Acid
A
A
A
A
D
A
A
A
A
A
D
A
Aluminum Chloride
Aluminum Sulfate (Alums)
Ammonia (Anhydrous Liquids)
Ammonia (Aqueous)
Ammoniated Latex
Ammonium Chloride
A
A
D
A
A
A
A
A
D
A
C
A
Cyclohexane
DDT Weed Killer
Dibutyl Phthalate
Diesel Oils
Diethylene Glycol
Diethyl Ether
B
A
D
C
B
A
C
C
D
D
C
C
Methyl Acetate
Methyl Alcohol
Methyl Bromide
Methyl Ethyl Ketone
Methylene Chloride
Mineral Oil
D
C
D
D
D
D
C
D
D
D
Ammonium Hydroxide
Amyl Acetate
Aniline Oils
Aromatic Hydrocarbons
Asphalt
A
D
D
D
D
A
D
D
D
D
C
D
C
D
A
A
A
D
D
D
C
C
D
Monochlorobenezene
Muriatic Acid (see Hydrochloric Acid)
Naphtha
Naphthalene
Nitric Acid
10%
Nitric Acid
35%
A
C
D
B
C
A
A
A
D
D
D
B
C
D
A
ASTM Fuel A
ASTM Fuel B
ASTM #1 Oil
ASTM #3 Oil
Barium Chloride
Barium Sulfide
Barium Hydroxide
Di-isodecyl Phthalate
Dioctyl Phthalate
Dow General Weed Killer (Phenol)
Dow General Weed Killer (H2O)
Ethyl Alcohol
Ethylene Dichloride
C
D
A
A
D
D
B
C
Ethylene Glycol
Ferric Chloride
Ferric Sulfate
Ferrous Chloride
Ferrous Sulfate
Formaldehyde
B
A
A
A
A
D
C
A
A
A
A
D
Nitric Acid
Oleic Acid
Oleum
Oxalic Acid
Pentachlorophenol in Oil
Pentane
D
A
D
A
B
C
D
C
D
A
C
D
Benzene (Benzol)
Benzine (Petroleum Ether)
Black Liquor
Bordeaux Mixture
Boric Acid
Butyl Acetate
D
C
A
A
A
D
D
C
A
A
A
D
Fuel Oil
Furfural
Gallic Acid
Gasoline (Hi Test)
Glycerine
Grease
B
C
A
C
A
A
C
C
A
D
A
C
Perchloroethylene
Petroleum Ether
Phenol
Phosphoric Acid
Pitch
Potassium Hydroxide
B
C
A
A
A
C
C
C
A
A
B
D
Butyl Alcohol
Calcium Hydroxide
Calcium Hypochlorite
Carbolic Acid (Phenol)
Carbon Dioxide
Carbon Disulfide
B
A
A
B
A
D
C
A
A
C
A
D
Green Sulfate Liquor
Heptachlor in Petroleum Solvents
Heptane
Hexane
Hydrobromic Acid
Hydrochloric Acid
10%
A
A
C
C
A
A
A
C
D
D
A
A
Sodium Cyanide
Stoddard Solvent
Styrene
Sulfur Dioxide (liquid)
Sulfuric Acid
Sulfuric Acid
A
D
D
D
A
D
A
D
D
D
B
D
Carbon Tetrachloride
Carbonic Acid
Casein
Caustic Soda
Chlorine Gas (wet)
Chlorine Gas (dry)
D
A
A
A
D
D
D
A
C
B
D
D
Hydrochloric Acid
Hydrofluoric Acid
Hydrofluorosilicic Acid
Hydrofluorosilicic Acid
Hydrogen Peroxide
Iso-Octane
C
D
A
A
A
C
C
D
A
A
B
C
Sulfurous Acid
Tall Oil
Tannic Acid
Toluene
Trichlorethylene
Triethanol Amine
B
D
A
D
D
C
C
D
A
D
D
D
Chlorine (water solution)
Chlorobenzene
Chlorinated Hydrocarbons
Chromic Acid
Citric Acid
Coal Tar
C
D
D
B
A
D
D
D
D
C
A
D
Isopropyl Acetate
Isopropyl Acid
Jet Fuels (JP-3, and 5)
Kerosene
Ketones
Linseed Oil
D
B
C
C
D
A
D
C
D
C
D
A
Tricresyl Phosphate (Skydrol)
Turpentine
Vinegar
Vinyl Chloride
Water
White Liquor
D
C
A
D
A
A
D
D
B
D
A
A
Xylene
Zinc Chloride
Zinc Sulfate
D
A
A
D
A
A
40%
70%
10%
Note: * Conc. - Concentration.
(All ratings apply to concentrated or saturated solutions unless otherwise specified.)
Chemical resistance ratings are based upon information supplied by the raw material manufacturers.
Use as a general guide only – samples should be tested by user under actual conditions.
Rating Code
A-Excellent service
No harmful effect to reduce service life . Suitable for
continuous service .
B-Good service life.
Moderate to minor effect . Good for intermittent service .
Generally suitable for continuous service .
Dimensions in Inches (cm)
70%
10%
50%
50%
98%
C-Fair or limited service.
Depends on operating conditions . Generally suitable for
intermittent service . Not recommended for continuous service .
D-Unsatisfactory service.
Not recommended .
www.hubbell-wiring.com
T-111
Technical Information
Acetate Solvents
Acetic Acid
Acetic Acid (Glacial)
Acetone
Acrylontrile
Alcohols (Aliphatic)
Kellems® Wire Management Products
Kellems® Wire Management Products
Kellems® Wire Management Products
Kellems® Wire Management Products
Technical Information
Non-Metallic Liquidtight Fittings
PolyTuff Fittings
Operating Temperature*
Nylon (Body, Nut, Gripping Ring and Locknut)
Neoprene (Sealing Ring)
–40°F to +225°F (–40°C to +107°C) .
–30°F to +240°F (–34°C to +116°C) .
Flammability
Fire Gas Toxicity Product Testing
Nylon PolyTuff Fittings have a UL 94V-2 rating .
Certifications
UL Listed
CSA Certified
UL50 Type 4X, 12 and 13 .
PolyTuff I Fittings, Poly Tuff II Fittings .
Liquidtight Fittings
Operating Temperature**
Steel/Malleable Iron (Nut, Body, Ferrule)
Nylon (Gland Ring)
–60°F to +1000°F (–51°C to +538°C) .
–40°F to +225°F (–40°C to +107°C) .
Hazardous Locations - NEC Reference
Class I, Div . 2 - 501-10(A)(3)B
Class II, Div . 1 - 502-10(A)(2)
Class II, Div . 2 - 502-10(A)(3)
Class III, Div . 1 - 503-10(A)(2)
Class III, Div . 2 - 503-10(B)
Certifications
UL Listed
CSA Certified
Technical Information
Note: * Due to the limiting factors of nylon and neoprene, PolyTuff Fittings will continuously perform in the range –30°F to +225°F (–34°C to +107°C).
** Due to the limiting factors of nylon, metallic liquidtight flexible conduit fittings will continuously perform in the range of –40°F to +225°F (–40°C to +107°C).
T-112
www.hubbell-wiring.com
Dimensions in Inches (cm)
Kellems® Wire Management Products
Kellems® Wire Management Products
Technical Information
Non-Metallic Liquidtight Fittings
E
Straight with Male Non-Metallic Liquidtight Fittings
Trade
Size
(md**)
A
B
C
D
Throat
Dia.
¼
(10)
³⁄₈
(12)
½
(16)
¾
(21)
1
(27)
1¼
(35)
1½
(41)
2
(53)
.93"
(23 .6)
1 .14"
(29 .0)
1 .30"
(33 .0)
1 .53"
(38 .9)
1 .80"
(45 .7)
2 .20"
(55 .9)
2 .49"
(63 .2)
3 .05"
(77 .4)
1 .45"
(36 .8)
1 .63"
(41 .4)
2 .14"
(54 .4)
2 .22"
(56 .4)
2 .32"
(58 .9)
2 .15"
(54 .6)
2 .35"
(59 .7)
2 .51"
(63 .6)
.39"
(9 .9)
.57"
(14 .5)
.57"
(14 .5)
.58"
(14 .7)
.72"
(18 .3)
.74"
(18 .8)
.76"
(19 .3)
.79"
(20 .1)
.32"
(8 .1)
.42"
(10 .7)
.55"
(14 .0)
.74"
(18 .8)
.96"
(24 .4)
1 .30"
(33 .0)
1 .46"
(37 .1)
1 .90"
(48 .3)
E
A/C*
A/F*
A
Dia.
.86" (Dia .)
(21 .8)
1 .41"
(35 .8)
1 .41"
(35 .8)
1 .85"
(47 .0)
1 .94"
(49 .3)
2 .38"
(60 .5)
2 .63"
(66 .8)
3 .13"
(79 .5)
1 .30"
(33 .0)
1 .30"
(33 .0)
1 .53"
(38 .9)
1 .80"
(45 .7)
2 .18"
(55 .4)
2 .43"
(61 .7)
2 .93"
(74 .4)
D
C
B
Sizes: ¼", 1¼", 1½", 2"
E
A
D
C
B
Note: * A/C = Across Corners A/F = Across Flats.
** md = metric designator.
Sizes: 3/8", ½", ¾", 1"
90° with Male Non-Metallic Liquidtight Fittings
Trade
Size
(md**)
A
¼
(10)
1¼
(35)
.93"
(23 .6)
2 .21"
(56 .1)
B
C
1 .88"
(47 .8)
3 .57"
(90 .7)
.39"
(9 .9)
.74"
(18 .9)
D
Throat
Dia.
.32"
(8 .1)
1 .30"
(33 .0)
E
A/C*
B
A/F*
.86"(Dia .)
(21 .8)
2 .38"
(60 .5)
2 .18"
(55 .4)
A
Dia.
E
Note: * A/C = Across Corners A/F = Across Flats.
** md = metric designator.
SwivelLok® Multi-Position Liquidtight Fittings
Trade
Size
(md**)
A
³⁄₈
(12)
½
(16)
¾
(21)
1
(27)
1 .30"
(33 .0)
1 .30"
(33 .0)
1 .53"
(38 .9)
1 .80"
(45 .7)
B
C
3 .27"
(83 .1)
3 .27"
(83 .1)
3 .66"
(93 .0)
4 .00"
(101 .6)
.57"
(14 .5)
.57"
(14 .5)
.58"
(15 .7)
.72"
(18 .3)
D
.55"
(14 .0)
.55"
(14 .0)
.74"
(18 .8)
.96"
(24 .4)
E
C
F
1 .43"
(36 .3)
1 .43"
(36 .3)
1 .59"
(40 .4)
1 .84"
(46 .7)
G
2 .00"
(50 .8)
2 .00"
(50 .8)
2 .23"
(56 .6)
2 .30"
(58 .4)
D
A/C*
A/F*
1 .41"
(35 .8)
1 .41"
(35 .8)
1 .65"
(41 .9)
1 .94"
(49 .3)
1 .30"
(33 .0)
1 .30"
(33 .0)
1 .53"
(38 .9)
1 .80"
(45 .7)
A
F
G
D
C
E
90° Position
Dimensions in Inches (cm)
B
45° Position
www.hubbell-wiring.com
Straight Position
T-113
Technical Information
Note: * A/C = Across Corners A/F = Across Flats.
** md = metric designator.
Kellems® Wire Management Products
Kellems® Wire Management Products
Technical Information
Metallic Liquidtight Fittings
Straight with Male Metallic Metal Fitting
E
D
Throat
Dia.
C
A
B
Ref.
Trade Size
(md**)
A
Ref.
B
³⁄₈
(12)
½
(16)
¾
(21)
1
(27)
1¼
(35)
1½
(41)
2
(53)
2½
(63)
3
(78)
3½
(91)
4
(103)
1 .43"
(36 .3)
1 .43"
(36 .3)
1 .56"
(39 .6)
1 .68"
(42 .7)
2 .03"
(51 .6)
2 .21"
(56 .1)
2 .28"
(57 .9)
3 .56"
(90 .4)
3 .81"
(96 .8)
3 .81"
(96 .8)
3 .81"
(96 .8)
.59"
(15 .0)
.59"
(15 .0)
.59"
(15 .0)
.66"
(16 .8)
.63"
(16 .8)
.63"
(16 .8)
.69"
(17 .5)
1 .06"
(26 .9)
1 .06"
(26 .9)
1 .06"
(26 .9)
1 .06"
(26 .9)
A/C*
C
1 .20"
(30 .0)
1 .34"
(34 .0)
1 .55"
(39 .0)
1 .95"
(50 .0)
2 .39"
(61 .0)
2 .72"
(69 .0)
3 .08"
(78 .0)
3 .92"
(100 .0)
4 .70"
(119 .0)
5 .29"
(134 .0)
5 .75"
(146 .0)
A/F*
D
Throat Dia.
A/C*
E
1 .06"
(26 .9)
1 .19"
(30 .2)
1 .37"
(34 .8)
1 .69"
(42 .9)
2 .06"
(52 .3)
2 .38"
(60 .5)
2 .87"
(72 .9)
3 .62"
(91 .9)
4 .31"
(109 .5)
4 .81"
(122 .2)
5 .31"
(134 .9)
.61"
(15 .5)
.61"
(15 .5)
.84"
(21 .3)
1 .06"
(26 .9)
1 .37"
(34 .8)
1 .53"
(38 .9)
2 .06"
(52 .3)
2 .42"
(61 .5)
3 .01"
(76 .5)
3 .49"
(88 .6)
3 .96"
(100 .6)
1 .07"
(27 .2)
1 .22"
(31 .0)
1 .43"
(36 .3)
1 .73"
(43 .9)
2 .36"
(59 .9)
2 .79"
(70 .9)
3 .32"
(84 .3)
3 .85"
(97 .8)
4 .65"
(118 .1)
5 .18"
(131 .6)
5 .75"
(146 .1)
A/F*
E
Throat Dia.
A/C*
1 .06"
(26 .9)
1 .19"
(30 .2)
1 .45"
(36 .8)
1 .69"
(42 .9)
2 .06"
(52 .3)
2 .38"
(60 .5)
2 .88"
(73 .2)
.60"
(15 .2)
.61"
(15 .2)
.84"
(21 .3)
1 .05"
(26 .7)
1 .37"
(34 .8)
1 .60"
(40 .6)
2 .05"
(52 .1)
1 .16"
(29 .5)
1 .21"
(30 .7)
1 .50"
(38 .1)
1 .82"
(46 .2)
2 .32"
(58 .9)
2 .62"
(66 .5)
3 .21"
(81 .5)
A/F*
D
Ref.
E
Throat Dia.
A/C*
1 .06"
(26 .9)
1 .12"
(28 .4)
1 .45"
(36 .8)
1 .60"
(40 .6)
2 .06"
(52 .3)
2 .38"
(60 .5)
2 .87"
(72 .9)
3 .63"
(92 .2)
4 .31"
(109 .5)
5 .31"
(134 .9)
1 .44"
(36 .6)
1 .44"
(36 .6)
1 .63"
(41 .4)
2 .19"
(55 .6)
2 .50"
(63 .5)
2 .69"
(68 .3)
3 .25"
(82 .6)
4 .25"
(108 .0)
4 .87"
(123 .7)
5 .63"
(143 .0)
.60"
(15 .2)
.61"
(15 .5)
.83"
(21 .1)
1 .05"
(26 .7)
1 .36"
(34 .5)
1 .61"
(40 .9)
2 .05"
(52 .1)
2 .42"
(61 .5)
3 .01"
(76 .5)
3 .96"
(100 .6)
1 .13"
(29 .0)
1 .12"
(28 .0)
1 .48"
(38 .0)
1 .80"
(46 .0)
2 .32"
(59 .0)
2 .58"
(66 .0)
3 .14"
(80 .0)
3 .78"
(96 .0)
4 .64"
(118 .0)
5 .76"
(146 .0)
A/F*
.93"
(23 .6)
1 .06"
(26 .9)
1 .25"
(31 .8)
1 .56"
(39 .6)
2 .08"
(52 .8)
2 .48"
(63 .0)
2 .90"
(73 .7)
3 .60"
(91 .4)
4 .33"
(110 .0)
4 .82"
(122 .4)
5 .39"
(136 .9)
45° with Male Metallic Metal Fitting
B
A
D
F
C
E
Throat
Dia.
Trade Size
(md**)
A
B
C
³⁄₈
(12)
½
(16)
¾
(21)
1
(27)
1¼
(35)
1½
(41)
2
(53)
1 .19"
(30 .2)
1 .19"
(30 .2)
1 .19"
(30 .2)
1 .38"
(35 .1)
1 .42"
(36 .1)
1 .66"
(42 .2)
1 .69"
(42 .9)
1 .28"
(32 .5)
1 .28"
(32 .5)
1 .43"
(36 .3)
1 .53"
(38 .9)
1 .69"
(42 .9)
2 .00"
(50 .8)
2 .25"
(57 .2)
.59"
(15 .0)
.59"
(15 .0)
.59"
(15 .0)
.66"
(16 .8)
.63"
(16 .0)
.66"
(16 .8)
.66"
(16 .8)
A/C*
D
1 .20"
(30 .5)
1 .34"
(34 .0)
1 .55"
(39 .4)
1 .95"
(49 .5)
2 .39"
(60 .7)
2 .72"
(69 .1)
3 .08"
(78 .2)
F
A/F*
1 .02"
(25 .9)
1 .06"
(26 .9)
1 .32"
(33 .5)
1 .59"
(40 .4)
2 .03"
(5 .16)
2 .29"
(58 .2)
2 .80"
(71 .1)
90° with Male Metallic Metal Fitting
F
Technical Information
C
D
B
A
E
Throat
Dia.
Trade Size
(md**)
A
B
³⁄₈
(12)
½
(16)
¾
(21)
1
(27)
1¼
(35)
1½
(41)
2"
(53)
2½
(63)
3
(78)
4
(103)
1 .31"
(33 .3)
1 .31"
(33 .3)
1 .44"
(36 .6)
1 .78"
(45 .2)
1 .97"
(50 .0)
2 .19"
(55 .6)
2 .53"
(64 .3)
3 .44"
(87 .4)
3 .75"
(95 .3)
4 .25"
(108 .0)
.59"
(15 .0)
.59"
(15 .0)
.59"
(15 .0)
.59"
(15 .0)
.63"
(16 .0)
.63"
(16 .0)
.66"
(16 .8)
1 .00"
(25 .4)
1 .00"
(25 .4)
1 .00"
(25 .4)
A/C*
C
1 .20"
(30 .5)
1 .34"
(34 .0)
1 .55"
(39 .4)
1 .95"
(49 .5)
2 .39"
(60 .7)
2 .72"
(69 .1)
3 .08"
(78 .2)
3 .92"
(99 .6)
4 .70"
(119 .4)
5 .75"
(146 .1)
F
A/F*
.99"
(25 .1)
1 .00"
(25 .4)
1 .29"
(32 .8)
1 .57"
(39 .9)
2 .02"
(51 .3)
2 .25"
(57 .2)
2 .75"
(69 .9)
3 .50"
(88 .9)
4 .30"
(109 .2)
5 .38"
(136 .7)
Note: * A/C = Across Corners A/F = Across Flats.
** md = metric designator.
T-114
www.hubbell-wiring.com
Dimensions in Inches (cm)