0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
ATD1000CRP

ATD1000CRP

  • 厂商:

    HUBBELL(哈伯尔公司)

  • 封装:

  • 描述:

    ADT OCCSENS, CLG MT, 1000 SQ FT

  • 数据手册
  • 价格&库存
ATD1000CRP 数据手册
Occupancy Sensors Index Category Introduction Features and Benefits Features and Benefits Specifications and Wiring Schematics Product Page Number Adaptive Technology Occupancy Sensors D-2 Adaptive Technology Wall Switches D-3 Adaptive Dual Technology Wall Switches D-4 Adaptive Ultrasonic Wall Switches D-4 Adaptive Passive Infrared Wall Switches D-5 Passive Infrared Wall Switches D-6 Adaptive Technology Ceiling and Wall Mount Occupancy Sensors D-7 Adaptive Dual Technology Ceiling Sensors D-8 Adaptive Ultrasonic Ceiling Sensors D-9 Adaptive Passive Infrared Ceiling Sensors D-10 Adaptive Dual Technology and Passive Infrared Wall Mount Sensors D-11 Control Units and Add-A-Relay D-12 Outdoor Sensor D-13 Dual Technology and Ultrasonic Wall Switches D-14 Passive Infrared Wall Switches Ceiling and Wall Mount Sensors - Specifications Outdoor Sensor Control Units and Add-A-Relay - Specifications Ceiling and Wall Mount Sensors/Control Unit - Wiring Schematics Occupancy Sensors Section D D-15–16 D-17 D-17 D-18 D-19–20 Index Dimensions in Inches (mm) www.hubbell-wiring.com Occupancy Sensors Introduction H-MOSS® Occupancy Sensors Adaptive Technology Occupancy Sensors Introduction Adaptive Technology sensing technology is a Hubbell breakthrough that not only delivers benefits for those who occupy offices, conference rooms and other interior spaces, but significant advantages for architects, specifiers, contractors and building owners as well. That’s because Adaptive Technology sensors use microprocessor-based technology to solve the three major problems of conventional occupancy sensors–false-ons, false-offs and the need for continuous manual adjustment. Switching lights off accidentally, even when a space is occupied, is no longer a nuisance with Hubbell Adaptive Technology sensors. Likewise, the false-ons caused by HVAC systems and other factors are a thing of the past. Adaptive Technology Sensors Automatically Adjust Time Delays Adaptive Technology sensors automatically adjust the time delay setting found in all occupancy sensors based on the activity level of the area’s occupant or occupants. It literally “fingerprints” movements, motion patterns and occupancy habits by recording them in the microprocessor’s memory. This prevents “false-offs” that result when a sensor’s time delay is too short for the occupant’s activity level. Adaptive Technology Sensors Automatically Adjust Sensitivity Not only can seasonal temperature changes cause false-offs, changes in office layout, including arrangement and density of furniture and the number of occupants, can cause them as well. Conversely falseons are caused by air currents created by HVAC systems and hallway traffic outside an area controlled by a nonadaptive sensor. Adaptive Technology sensors prevent these problems by automatically adjusting their sensitivity. D-2 Adaptive Technology Sensors Head a Complete Family of Hubbell Occupancy Sensors. Hubbell offers a full line of occupancy sensors that incorporates all three sensing technologies: Dual Technology, Passive Infrared (PIR) and Ultrasonic. Adaptive Technology is offered on Dual Technology, PIR and Ultrasonic models. For non-critical areas–for instance, seldom-used spaces such as storage closets–Hubbell also offers PIR wall switches without Adaptive Technology. and outdoor sensors. The product family also includes control units, adapter plates and all other accessories and peripheral devices. Hubbell occupancy sensors featuring Adaptive Technology sensing technology: They’re assuring a bright future for all types of buildings, including yours. Hubbell occupancy sensors are available in wall and ceilingmount models as well as hallway www.hubbell-wiring.com Adaptive Technology Sensors Put an End to False-Offs Many people have had the experience: They’re sitting in an office, not moving much and, suddenly, the lights go off. They wave their arms to get them back on. The same problem may occur when a large room is occupied in off-peak hours. With an Adaptive Technology sensor, if motion is detected within 15 seconds of a lights-off command, it is logged as a major error by the microprocessor. A number of corrections are initiated automatically by the sensor to adapt to the areas usage pattern. Dimensions in Inches (mm) Occupancy Sensors H-MOSS® Occupancy Sensors Adaptive Dual Technology Wall Switches Features and Benefits Ivory and white models available to match office decor. Designed for use on 120 or 277V AC circuits. Dual Technology sensing combines the individual advantages of passive infrared and ultrasonic detection. Override switch allows lights to be manually turned off. Available in standard or hard lens versions for high abuse applications. Bi-colored LED. Red indicates passive infrared detection. Green indicates ultrasonic detection. Digital pushbutton ambient light level control located behind wall plate allows for quick, accurate setting of ambient light threshold. Adaptive Passive Infrared Wall Switches Features and Benefits Heavy-duty relay controls up 1800 watts at 120V AC or 4155 watts at 277V AC. Ivory and white models available to match office decor. High density 1200 square foot coverage. Two-color LED provides instant feedback of sensor status. Digital pushbutton ambient light level control located beh cover allows for quick, accura setting of ambient light thresh Front press switch allows the occupant to switch the sensor from automatic operation to momentary off mode. The sensor returns to automatic operation mode 30 minutes after the last detected motion. Designed for use on 120 or 277V AC circuits. Dimensions in Inches (mm) www.hubbell-wiring.com D-3 Features and Benefits Soft tone alert provides aud indication of sensor time-ou 12 seconds prior to switchin lights out. Occupancy Sensors H-MOSS® Occupancy Sensors Adaptive Technology Wall Switches Dual Technology and Ultrasonic Hubbell ATD series wall switch sensors incorporate both ultrasonic and passive infrared detection technologies. These dual technology sensors provide the most reliable means of automatic lighting control. The product offering includes standard and hard lens versions for high abuse applications. Hubbell dual technology wall switch sensors are the best choice for enclosed office applications. ATD1277I, ATD1277W ATD1277HI, ATD1277HW Description Adaptive Technology, dual (passive infrared and ultrasonic40kHz), wall switch, ivory, 120/277V AC, 25 to 600 watts at 120V AC, 60 to 1200 watts at 277V AC, 1000 sq. ft. coverage, with photocell. Same as above except white. Adaptive Technology, dual (passive infrared and ultrasonic40kHz), wall switch, hard lens, ivory, 120/277V AC, 25 to 600 watts at 120V AC, 60 to 1200 watts at 277V AC, 300 sq. ft. coverage, with photocell. Same as above except white. Catalog Numbers ATD1277I ATD1277W ATD1277HI ATD1277HW Hubbell ATU series wall switch sensors detect occupancy based on an ultrasonic signal. Since these sensors do not require line of sight to detect occupancy, they work particularly well in areas with obstructions such as storage areas and restrooms. The manual override switch is eliminated on the restroom model to prevent the light from being turned off. Description Adaptive Technology, ultrasonic- 40 kHz, wall switch, ivory, 120/277V AC, 25 to 600 watts at 120V AC, 60 to 1200 watts at 277V AC, 1000 sq. ft. coverage. Same as above except white. Adaptive Technology, ultrasonic- 40 kHz, wall switch for restroom use, ivory, 120/277V AC, 25 to 600 watts at 120V AC, 60 to 1200 watts at 277V AC, 1000 sq. ft. coverage. Same as above except white. ATU1277I, ATU1277W Catalog Numbers ATU1277I ATU1277W ATU1277RRI ATU1277RRW Notes: Nylon wall plate supplied with each sensor. ATD and ATU series wall switch sensors are gangable. See section K for additional wall plates. See page D-14 for technical data and wiring schematics. ATU1277RRI, ATU1277RRW Coverage Patterns Wall Switches 0 5 10 15 20 25 Ultrasonic Passive Infrared 30 0 35 5 10 15 20 25 30 35 0 20 20 20 15 15 15 10 10 10 5 5 5 0 0 0 5 5 5 10 10 10 15 15 15 20 20 D-4 ATD1277I ATD1277W ATD1277HI ATD1277HW www.hubbell-wiring.com 20 5 10 15 20 25 30 35 ATU1277I, ATU1277W ATU1277RRI, ATU1277RRW Dimensions in Inches (mm) Occupancy Sensors H-MOSS® Occupancy Sensors Adaptive Technology Wall Switches Passive Infrared Hubbell AT1277 and ATP1277 series wall switch occupancy sensors utilize passive infrared technology to determine occupancy. These sensors require line of sight to detect body heat in motion. Wall switch occupancy sensors are best suited for small enclosed spaces such as offices, conference rooms, storage closets, small lunch rooms and copy rooms. Hubbell’s complete offering of wall switch sensors enables you to choose the right product for these various applications. Hubbell AT1277 series wall switches feature a heavy duty relay and zero crossing circuitry to provide the ability to switch up to 15A lighting loads. In addition, they incorporate Adaptive Technology for performance critical applications such as enclosed offices and conference rooms. Adaptive Technology sensors automatically adjust the time delay setting to fit the application. This prevents falseoffs that result when a sensor’s time delay is set too short for the activity level of the occupant. Product features and benefits are provided on page D-3. Description Adaptive Technology, passive infrared, wall switch, ivory, 120/277V AC, 1800 watts at 120V AC, 4155 watts at 277V AC, 1200 sq. ft. coverage, with photocell. Same as above except white. AT1277I, AT1277W Catalog Numbers AT1277I AT1277W Hubbell ATP series Adaptive Technology wall switch sensors are dual voltage rated for use on 120V or 277V AC applications. These sensors feature a pushbutton ambient light level control that allows for quick, accurate setting of the ambient light level threshold. Description Adaptive Technology, passive infrared, wall switch, ivory, 120/277V AC, 800 watts at 120V AC, 1200 watts at 277V AC, 1200 sq. ft. coverage, with photocell. Same as above except white. Same as above except gray. Catalog Numbers ATP1277I ATP1277W ATP1277GY ATP1277I, ATP1277W ATP1277GY Notes: Nylon wall plate supplied with each sensor. AT and ATP series wall switches are gangable. See section K for additional wall plates. See page D-15 for technical data and wiring schematics. Coverage Patterns Passive Infrared 15 10 5 0 5 10 15 40 Wall Switches 32' 35 30 25 20 40' 15 10 5 0 Horizontal Coverage Dimensions in Inches (mm) www.hubbell-wiring.com D-5 Occupancy Sensors H-MOSS® Occupancy Sensors Wall Switches Passive Infrared Hubbell WS1277 series wall switch sensors include a manual adjustment that allows the time delay to be set from 20 seconds to 30 minutes. This adjustment is concealed behind a front cover to prevent tampering. These sensors also feature a pushbutton ambient light level control that allows for quick, accurate setting of the ambient light level threshold. Description Passive infrared, wall switch, ivory, 120/277V AC, 800 watts at 120V AC, 1200 watts at 277V AC, 1200 sq. ft. coverage, with photocell. Same as above except white. Catalog Numbers WS1277I WS1277W Hubbell WS series wall switch sensors include a manual adjustment that allows the time delay to be set from 30 seconds to 30 minutes. These sensors provide the most economical means of automatic lighting control. WS1277I, WS1277W Description Passive infrared, wall switch, ivory, 120V AC, 800 watts incandescent, 1000 watts fluorescent, 900 sq. ft. coverage. Same as above except white. Passive infrared, wall switch, ivory, 277V AC, 1800 watts fluorescent, 900 sq. ft. coverage. Same as above except white. Catalog Numbers WS120I WS120W WS277I WS277W Hubbell WS1277W2 passive infrared wall switch sensor is a double pole, single throw wall switch with two separate relays. This wall switch can be used for dual level switching from one or two circuits. WS120I, WS120W WS277I, WS277W Description Passive infrared, wall switch, ivory, double pole, white 120/277V AC, 600 watts per circuit at 120V AC incandescent, 1000 watts per circuit at 120V AC fluorescent, 1800 watts at 277V AC fluorescent, 1000 sq. ft. coverage. Wall switch adapter plate for Hubbell WS1277W2. Two-gang wall plate allows one WS1277W2 to mount to a two gang box. Coverage Patterns 10 5 0 5 10 40 32' Wall Switches 35 15 15 5 0 5 10 15 40 40 35 35 25 25 40' 10 40 30 20 30 20 10 0 10 20 30 40 30 32' 35' 25 20 15 15 15 10 10 10 5 5 5 0 0 0 WS1277I, WS1277W D-6 Passive Infrared 30 20 WSAP Notes: Nylon wall plate supplied with each sensor except WS1277W2 (not required in 1-gang applications). All wall switches are gangable except WS1277W2. See section K for additional wall plates. See pages D-15-16 for technical data and wiring schematics. WS1277W2 15 Catalog Numbers WS1277W2 WS120, WS277 Series www.hubbell-wiring.com 72' 36' WS1277W2 Dimensions in Inches (mm) Adaptive Technology Ceiling Sensors Features and Benefits LED sensing indicators - red for PIR, green for ultrasonic. Occupancy Sensors H-MOSS® Occupancy Sensors Isolated relay included on sensors with "RP" suffix for interfacing sensor to auxiliary systems such as HVAC. Ultrasonic transmitter and receiver for coverage in each direction for superior sensing of motion. Off-white ABS enclosure blends with ceiling tile. Dual element passive-infrared detector and lens sense heat in motion. Ambient light level control featured on sensors with "RP" suffix to prevent unnecessary lighting usage when natural light is sufficient. Adaptive Technology Wall Mount Sensors Features and Benefits Swivel mounting bracket allows sensor to be easily adjusted in ceiling or wall mount applications. Dual technology sensing combines the individual advantages of passive infrared and ultrasonic detection. Green LED indicates ultrasonic detection. Ambient light level control featured on sensors with "RP" suffix to prevent unnecessary lighting usage when natural light is sufficient. Red LED indicates passive infrared detection. Dimensions in Inches (mm) Features and Benefits 110 degree coverage provides complete room sensing when corner mounted. www.hubbell-wiring.com D-7 Occupancy Sensors H-MOSS® Occupancy Sensors Adaptive Technology Ceiling Sensors Dual (Ultrasonic and Passive Infrared) Hubbell ATD series sensors incorporate both ultrasonic and passive infrared detection technologies. These dual technology sensors provide the most reliable means of automatic lighting control. Common applications include open office spaces, conference rooms, classrooms and executive offices where flawless performance is necessary. An isolated relay and photocell are included on models with “RP” suffix. A CU series control unit is required for use with ATD series sensors. Description Adaptive Technology, dual (passive infrared & ultrasonic-32kHz), 2000 sq. ft. coverage, with isolated relay and photocell. Adaptive Technology, dual (passive infrared & ultrasonic-32kHz), 2000 sq. ft. coverage. Adaptive Technology, dual (passive infrared & ultrasonic-32kHz), 1000 sq. ft. coverage, with isolated relay and photocell. Adaptive Technology, dual (passive infrared & ultrasonic-32kHz), 1000 sq. ft. coverage. Adaptive Technology, dual (passive infrared & ultrasonic-40kHz), 500 sq. ft. coverage, with isolated relay and photocell. Adaptive Technology, dual (passive infrared & ultrasonic-40kHz), 500 sq. ft. coverage. ATD2000CRP, ATD2000C Catalog Numbers ATD2000CRP ATD2000C ATD1000CRP ATD1000C ATD500CRP ATD500C Notes: A CU series control unit is required for use with ATP series ceiling sensors. See page D-12 for control units and Add-A-Relay. See pages D-17–20 for technical data and wiring schematics. ATD500CRP, ATD500C ATD1000CRP, ATD1000C Coverage Patterns Ultrasonic Passive Infrared 0 30 25 20 15 10 5 0 5 15 20 25 0 30 5 10 15 20 5 5 22' 0 12' 0 5 5 10 15 20 ATD2000CRP, ATD2000C D-8 10 15 20 10 10 10 5 30 15 15 15 25 20 20 20 Ceiling Sensors 10 5 12' 22' 0 12' 22' 5 10 10 15 15 20 20 ATD1000CRP, ATD1000C ATD500CRP, ATD500C www.hubbell-wiring.com Dimensions in Inches (mm) Occupancy Sensors H-MOSS® Occupancy Sensors Adaptive Technology Ceiling Sensors Ultrasonic Hubbell ATU series sensors detect occupancy based on an ultrasonic signal. Since these sensors do not require line of sight to detect occupancy, they work particularly well in areas with obstructions such as restrooms and storage rooms. Another common application is hallways. An isolated relay and photocell are included on models with “RP” suffix. A CU series control unit is required for use with ATU series sensors Description Adaptive Technology, ultrasonic-32kHz, 2000 sq. ft. coverage, with isolated relay and photocell. Adaptive Technology, ultrasonic-32kHz, 2000 sq. ft. coverage. Adaptive Technology, ultrasonic-32kHz, 1000 sq. ft. coverage, with isolated relay and photocell. Adaptive Technology, ultrasonic-32kHz, 1000 sq. ft. coverage. Adaptive Technology, ultrasonic-40kHz, 500 sq. ft. coverage, with isolated relay and photocell. Adaptive Technology, ultrasonic-40kHz, 500 sq. ft. coverage. Catalog Numbers ATU2000CRP ATU2000C ATU2000CRP, ATU2000C ATU1000CRP ATU1000C ATU500CRP ATU500C Notes: A CU series control unit is required for use with ATU series ceiling sensors. See page D-12 for control units and Add-A-Relay. See pages D-17–20 for technical data and wiring schematics. Coverage Patterns 30 25 20 15 10 ATU500CRP, ATU500C ATU1000CRP, ATU1000C Ultrasonic 5 0 5 10 15 20 25 30 0 5 10 15 20 25 30 0 35 20 20 20 15 15 15 10 10 10 5 5 5 0 0 0 5 5 10 15 20 5 10 10 15 15 15 20 20 20 ATU2000CRP, ATU2000C ATU1000CRP, ATU1000C ATU500CRP, ATU500C Dimensions in Inches (mm) www.hubbell-wiring.com 30 35 Ceiling Sensors 5 10 25 D-9 Occupancy Sensors H-MOSS® Occupancy Sensors Adaptive Technology Ceiling Sensors Passive Infrared Hubbell ATP series ceiling sensors detect occupancy based on a passive infrared signal. They are available with a wide view lens (ATP 1500C series) for large areas with multiple occupants and a high density lens (ATP600C series) for areas with a single occupant where small motion detection is desired. Each sensor includes an infrared masking kit which can be used to reduce the coverage area. Models with an “RP” suffix include an isolated relay and photocell. A CU series control unit is required for use with ATP series ceiling sensors. Description Adaptive Technology, passive infrared, wide view lens, 1500 sq. ft. coverage, with isolated relay and photocell. Adaptive Technology, passive infrared, wide view lens, 1500 sq. ft. coverage. Adaptive Technology, passive infrared, wide view lens, 600 sq. ft. coverage, with isolated relay and photocell. Adaptive Technology, passive infrared, wide view lens, 600 sq. ft. coverage. ATP600CRP, ATP600C ATP1500CRP, ATP1500C Catalog Numbers ATP1500CRP ATP1500C ATP600CRP ATP600C Notes: A CU series control unit is required for use with ATP series ceiling sensors. See page D-12 for control units and Add-A-Relay. See pages D-17–20 for technical data and wiring schematics. Coverage Patterns 25 Passive Infrared 20 15 10 5 0 5 10 15 20 25 25 15 10 5 0 5 10 15 20 15 15 10 10 5 0 22' 12' 5 0 5 10 12' 6'.5'' 5 5 15 10 Ceiling Sensors 20 D-10 25 15 ATP1500CRP, ATP1500C ATP600CRP, ATP600C www.hubbell-wiring.com Dimensions in Inches (mm) Occupancy Sensors H-MOSS® Occupancy Sensors Adaptive Technology Wall Mount Sensors Dual (Ultrasonic and Passive Infrared) and Passive Infrared The Hubbell Adaptive Technology wall mount sensor offering includes dual technology and passive infrared sensors with a 1600 square foot coverage pattern as well as passive infrared sensors for high bay applications in warehouse aisle ways. The wall mount sensors include a swivel mounting bracket that allows the sensor to be ceiling or wall mounted. This makes them suitable for applications with ceiling heights over 12 ft. The ceiling bracket is also designed to accept surface raceway for hard ceiling applications. Models with “RP” suffix include an isolated relay and photocell. A CU series control unit is required for use with ATD and ATP series wall mount sensors. Dual Technology Description Adaptive Technology, dual (passive infrared & ultrasonic32kHz), 1600 sq. ft. coverage, with isolated relay and photocell. Adaptive Technology, dual (passive infrared & ultrasonic32kHz), 1600 sq. ft. coverage. Catalog Numbers ATD1600WRP ATD1600W, ATD1600WRP ATD1600W Passive Infrared Description Catalog Numbers Adaptive Technology, passive infrared, ATP1600WRP 1600 sq. ft. coverage, with isolated relay and photocell. Adaptive Technology, passive infrared, ATP1600W 1600 sq. ft. coverage. Adaptive Technology, passive infrared, ATP120HBRP 120 linear ft. coverage for aisle ways in high bay applications, with isolated relay and photocell. Adaptive Technology, passive infrared, ATP120HB 120 linear ft. coverage for aisle ways in high bay applications. Notes: A CU series control unit is required for use with ATD & ATP series sensors. See page D-12 for control units and Add-A-Relay. See pages D-17–20 for technical data and wiring schematics. Coverage Patterns 0 Passive Infrared 5 10 15 20 25 30 35 40 45 50 0 Ultrasonic 5 10 15 20 25 30 35 40 45 50 40 35 30 25 20 15 10 5 0 5 10 15 20 25 30 35 40 40 35 30 25 20 15 10 5 0 5 10 15 20 25 30 35 40 ATD1600WRP, ATD1600W ATP1600WRP, ATP1600W ATP1600W, ATP1600WRP ATP120HB, ATP120HBRP Side View 0 10 20 30 40 50 60 70 80 90 100 110 120 30 20 Wall Mount Sensors 10 0 Top View 7 0 7 ATP120HBRP, ATP120HB Dimensions in Inches (mm) www.hubbell-wiring.com D-11 Occupancy Sensors H-MOSS® Occupancy Sensors Control Units and Add-A-Relay Control Units Hubbell CU series control units are required for use with Hubbell ATD, ATU and ATP series ceiling and wall mount sensors. The control units provide a 24V DC power supply for 1 to 3 sensors or sensor/Add-A-Relay combinations and contain an internal relay for the control of an external lighting load. CU120A, CU230A CU277A, CU347A Description Control Unit, 120V AC, 60 Hz, for use with ATD, ATU and ATP series ceiling and wall mount sensors. Control Unit, 230V AC, 50/60 Hz, for use with ATD, ATU and ATP series ceiling and wall mount sensors. Control Unit, 277V AC, 60 Hz, for use with ATD, ATU and ATP series ceiling and wall mount sensors. Control Unit, 347V AC, 60 Hz, for use with ATD, ATU and ATP series ceiling and wall mount sensors. Catalog Numbers CU120A CU230A CU277A CU347A Add-A-Relay Hubbell AAR Add-A-Relay is designed for use with Hubbell CU series control units and Hubbell ATD, ATU and ATP series ceiling and wall mount sensors. The AAR contains an internal relay for control of an external lighting load. The AAR requires a 24V DC power supply from the Hubbell CU series control unit. The AAR is typically used when: 1. It is desired to switch more than one circuit when occupancy is sensed. 2. The lighting load exceeds the maximum rating of the control unit. Description Catalog Number Add-A-Relay, for use with CU series control units. AAR Note: See pages D-18-20 for technical data and wiring schematics. Control Units and Add-A-Relay AAR D-12 www.hubbell-wiring.com Dimensions in Inches (mm) Occupancy Sensors H-MOSS® Occupancy Sensors MOTION ALERT Outdoor Sensor Passive Infrared Hubbell OS270BZ is a passive infrared sensor specifically designed for outdoor applications. The OS270BZ features a rugged metallic housing with an integral lens guard for abuse resistance, a conformal coated printed circuit board to prevent premature failure caused by moisture ingress and a durable multi-segmented lens for improved coverage and reliability. The OS270BZ provides a 270 degree coverage pattern with a range of up to 100 feet. Hubbell OS270BZ offers energy savings, convenience and security in outdoor applications. Description Outdoor sensor, passive infrared, bronze, 120V AC, 1000 watts, incandescent, with photocell. Catalog Number OS270BZ Operating Characteristics Time Out Test (5 seconds), 1, 5 or 20 minutes. Horizontal field of view 270 degrees. Vertical field of view 3 levels of vertical fields. Recommended mounting height 6-12 feet above ground. Control Adjustments The Hubbell OS270BZ motion detector has adjustments for time, sensitivity and range. The controls are located in a concealed control compartment on the bottom of the motion detector and are illustrated below. OS270BZ LED detection indicator provides visual verification of motion detection. Multi-segmented lens provides superior coverage and reliability. Range Boost extends the range from 70' to 100' from the sensor for large coverage applications. Dimensions in Inches (mm) Time Adjustment provides time out positions for testing (5 seconds), 1, 5, or 20 minutes. www.hubbell-wiring.com 270° Area blocked by lens shield (if used). D-13 Outdoor Sensor 100’ Sensitivity adjusts the sensitivity of the motion detector by increasing or decreasing the range. Occupancy Sensors H-MOSS® Occupancy Sensors Specifications and Wiring Schematics Dual Technology and Ultrasonic Wall Switches Adaptive Dual Technology Wall Switch ATD1277 Series Wall Switches Adaptive Technology Ultrasonic Wall Switch ATU1277 Series Wall Switches Electrical Power Supply Load Capacity 120V AC 277V AC Agency Approvals 25 to 600 watts. 60 to 1200 watts. UL Listed, cUL Certified. Electrical Power Supply Load Capacity 120V AC 277V AC Agency Approvals 25 to 600 watts. 25 to 1200 watts. UL Listed, cUL Certified. Physical Housing Lens Dimensions Mounting Height High impact plastic. Polyethylene. Face 2.60”H x 1.28”W, 0.58”D (from wall out). 42 to 54 inches above floor. Physical Housing Dimensions Mounting Height High impact plastic Face 2.60”H x 1.28”W, 0.58”D (from wall out). 42 to 54 inches above floor. Environmental Operating ATD1277 Series 120/277V AC, 60 Hz. 32° F to 104° F (0° C to 40° C) with rate of change not exceeding 20° F (11° C) per hour; 0% to 95% non-condensing relative humidity. -20° F to 150° F (-29° C to 65° C); 0% to 95% non-condensing relative humidity. Storage Controls Time Delay Ambient Light Front Press Switch Sensitivity Service Switch Digital, adaptive 4-32 mins. Digital pushbutton, 30 to 300 foot candles. Auto/Off. Adaptive 0% to 100%. Air gap off. Specifications and Wiring Schematics Sensing Indicator Passive Infrared Red LED. Ultrasonic Green LED. Environmental Operating Storage ATU1277 Series 120/277V AC, 60 Hz. 32° F to 104° F (0° C to 40° C) with rate of change not exceeding 20° F (11° C) per hour; 0% to 95% non-condensing relative humidity. -20° F to 150° F (-29° C to 65° C); 0% to 95% non-condensing relative humidity. Controls Time Delay Digital, adaptive 4-32 mins. (Restroom Model) 20 min. default. Front Press Switch Auto/Off except Restroom Model. Sensitivity Adaptive 0% to 100%. Service Switch Air gap off. Sensing Indicator Ultrasonic Green LED. Wiring Schematic ATD1277 and ATU1277 Series Wall Switch Sensors Wiring Schematic ATD1277 and ATU1277 Series Wall Switch Sensors Low Wattage Applications (yellow wire): 25-240 Watts at 120V AC 60-550 Watts at 277V AC Low Wattage Applications (red wire): 160-600 Watts at 120V AC 370-1200 Watts at 277V AC Normal Wiring Normal Wiring Hot Hot Green (Ground) Green (Ground) Yellow (Load) Neutral D-14 Black (Line) Black (Line) Yellow (Cap Off) Red (Cap Off) Lighting Load www.hubbell-wiring.com Neutral Red (Load) Lighting Load Dimensions in Inches (mm) Specifications Passive Infrared Wall Switches Adaptive Technology PIR Wall Switch AT1277 Series Wall Switches Adaptive Technology PIR Wall Switch ATP1277 and WS1277 Series Wall Switches Electrical Power Supply Load Capacity 120V AC 277V AC Agency Approvals Electrical Power Supply Load Capacity Incandescent 120V Ballast 277V Ballast Agency Approvals Physical Housing Lens Dimensions Mounting Height Environmental Operating AT1277 Series 120/277V AC, 50/60 Hz. 0 to 1800 watts. 0 to 4155 watts. UL Listed, cUL Certified. Physical Housing Lens Dimensions Flame retardant UL 94 V-0 ABS Polyethylene. Face 2.61” H x 1.29” W, 0.73” D (from wall out). 42 to 54 inches above floor. Mounting Height Environmental Operating 32° F to 122° F (0° C to 50° C) with rate of change not exceeding 20° F (11° C) per hour; 20% to 90% noncondensing relative humidity. -20° F to 150° F (-29° C to 65° C); 20% to 90% noncondensing relative humidity. Storage Controls Time Delay Service Switch Digital, test (15 seconds), Adaptive 5 to 30 minutes. Digital, pushbutton, 30 to 300 foot candles. Auto/Momentary Off (30 minutes after last motion, switch returns to automatic mode). Auto/Off. Sensing Indicators Passive Infrared 2-color LED, (red,green). Ambient Light Front Press Switch Storage Controls Time Delay ATP1277 Series ATP1277 Series, WS1277 Series 120/277V AC, 60 Hz. 0 to 800 watts 0 to 800 watts. 0 to 1200 watts. UL Listed, cUL Certified. Flame retardant UL 94 V-0 ABS Polyethylene. Face 2.61” H x 1.29” W, 0.73” D (from wall out). 42 to 54 inches above floor. 32° F to 122° F (0° C to 50° C) with rate of change not exceeding 20° F (11° C) per hour; 20% to 90% noncondensing relative humidity. -40° F to 150° F (-40° C to 65° C); 20% to 90% noncondensing relative humidity. Service Switch Digital, test (20 seconds), Adaptive 5 to 30 minutes. Manual 20 seconds -30 minutes. Digital, pushbutton, 30 to 300 foot candles. Auto/Momentary Off (30 minutes after last motion, switch returns to automatic mode). Auto/Off Sensing Indicators Passive Infrared Red LED. WS1277 Series Ambient Light Front Press Switch Parallel Wiring Hot Hot Black (Line) Black (Line) Green (Ground) Green (Ground) Red (Load) Neutral Green (Ground) Red (Load) Lighting Load Neutral Dimensions in Inches (mm) Black (Line) www.hubbell-wiring.com Red (Load) Lighting Load D-15 Specifications and Wiring Schematics Wiring Schematic AT1277, ATP1277 and WS1277 Series Wall Switches Normal Wiring Occupancy Sensors H-MOSS® Occupancy Sensors Occupancy Sensorsy H-MOSS® Occupancy Sensors Specifications and Wiring Schematics Passive Infrared Wall Switches Passive Infrared Wall Switches WS120I, WS120W, WS277I, WS277W Wiring Schematic WS120 and WS277 Series Wall Switches Electrical Power Supply Load Capacity Incandescent 120V Ballast 277V Ballast Agency Approvals WS120I, WS120W 120V AC, 60 Hz. WS277I, WS277W 277V AC, 60 Hz. 0 to 800 watts. 0 to 1000 watts. NA UL Listed, cUL Certified. NA NA 0 to 1800 watts. UL Listed, cUL Certified. Physical Housing Lens Dimensions Mounting Height WS120I, WS120W, WS277I, WS277W High-impact ABS. Polyethylene. Face 2.6”H x 1.3”W, 0.51”D (from wall out). 42 to 54 inches above floor. Environmental Operating Storage 32° F to 122° F (0° C to 50° C) with rate of change not exceeding 20° F (11° C) per hour; 20% to 90% noncondensing relative humidity. -40° F to 150° F (-40° C to 65° C); 20% to 90% noncondensing relative humidity. Controls Time Delay 30 seconds to 30 minutes. Front Press Switch Auto/Off. Manual Override Bypass Override ON key provided. Sensing Indicator Passive Infrared Normal Wiring Hot Black (Line) Green (Ground) Red (Load) Lighting Load Neutral Parallel Wiring Hot Black (Line) Black (Line) Green (Ground) Green (Ground) Red (Load) Red (Load) Red LED. Lighting Load Neutral Specifications and Wiring Schematics Passive Infrared Wall Switch for Dual Level Lighting WS1277W2 Electrical Power Supply Load Capacity Incandescent 120V Ballast 277V Ballast Agency Approvals 0 to 600 watts each circuit. 0 to 1000 watts each circuit. 0 to 1800 watts each circuit. UL Listed, cUL Certified. Physical Housing Lens Dimensions Mounting Height High-impact ABS. Polyethylene. Face 4.54”H x 2.79”W, 0.95” (from wall out). 42 to 54 inches above floor. Environmental Operating Storage WS1277W2 120/277V AC, 60 Hz. Dual Level Switching of Two Circuits Line (Hot) Circuit #1 D-16 Line (Hot) Circuit #2 Blue SW-1 Violet Lighting Load #2 Neutral Green (Ground) Lighting Load #1 SW-2 Black Red Neutral WS1277W2 32° F to 122° F (0° C to 50° C) with rate of change not exceeding 20° F (11° C) per hour; 20% to 90% noncondensing relative humidity. -40° F to 150° F (-40° C to 65° C); 20% to 90% noncondensing relative humidity. Controls Time Delay 3 to 30 minutes. Front Rocker Switches (two) Auto/Off. Manual Override Bypass Override ON key provided. Sensing Indicator Passive Infrared Wiring Schematic WS1277W2 Wall Switch Dual Level Switching of a Single Circuit Line (Hot) Blue SW-1 Violet Lighting Load #2 Neutral Green (Ground) SW-2 Black Red Lighting Load #1 Neutral WS1277W2 Red LED. www.hubbell-wiring.com Dimensions in Inches (mm) Occupancy Sensors H-MOSS® Occupancy Sensors Specifications and Wiring Schematics Ceiling and Wall Mount Sensors, Outdoor Sensor Adaptive Dual Technology, Ultrasonic and Passive Infrared Ceiling and Wall Mount Sensors ATD, ATU, ATP Series Ceiling and Wall Mount Sensors MOTION ALERT Passive Infrared Outdoor Sensor OS270BZ Electrical Power Requirements Electrical Power Supply 120V AC, 60 Hz. Sensor Load Capacity 1000W (8.3 amps) Incandescent. Agency Approvals UL Listed, cUL Certified. 24V DC nominal, 33mA from Hubbell CU series control unit Isolated Relay Normally open and normally closed. (sensors with RP suffix) terminals available. Agency Approvals UL Listed. Physical Housing Lens Dimensions Color Mounting Height Ceiling Sensors Flame retardant UL 94 V-0 ABS. Polyethylene. 4.5” diameter, 1.5” height. Office white. 8 to 12 feet. Physical Housing Lens Dimensions Color Mounting Height Wall Mount Sensors Flame retardant UL 94 V-0 ABS. Polyethylene. 6” H x 2” W x 1.5” D. Office white. 8 to 12 feet. Environmental Operating Storage Environmental Operating 32° F to 104° F (0° C to 40° C) with rate of change not exceeding 20° F (11° C) per hour; 0% to 95% noncondensing relative humidity. -20° F to 150° F (-29° C to 65° C); 0% to 95% non-condensing relative humidity. Cast metal. Polyethylene. 9.75” L x 4” W x 2.75” H. 6 to 12 feet above ground. Storage Relative Humidity -40° F to 150° F (-40° C to 66° C) with rate of change not exceeding 20° F (11° C) per hour. -40° F to 150° F (-40° C to 66° C). Raintight per UL773A. Controls Time Delay Ambient Light Sensitivity Range Boost Test (5 seconds), 1, 5 or 20 minutes. Photocell deactivates unit in daylight. 0 to 100%. Extends range from 70 ft. to 100 ft. Sensing Indicators Passive Infrared Red LED. Controls Time Delay Test (8 seconds), adaptive 8 to 40 minutes. Ambient Light 1 to 1000 foot candles. (sensors with RP suffix) terminals available Sensitivity Adaptive 0 to 100%. Wiring Schematic OS270BZ Outdoor Sensor Normal Wiring Hot Wall Switch Black (Line) OS270BZ White Neutral Dimensions in Inches (mm) www.hubbell-wiring.com Red (Load) Lighting Load D-17 Specifications and Wiring Schematics Sensing Indicators Ultrasonic Green LED. (ATD and ATU Series) Passive Infrared Red LED. (ATD and ATP Series) Physical Housing Lens Dimensions Mounting Height Occupancy Sensorsy H-MOSS® Occupancy Sensors Specifications Control Units and Add-A-Relay CU Series Control Units CU120A, CU230A, CU277A, CU347A Electrical Power Supply Power Output Load Capacity Incandescent 120V Ballast 230V Ballast 277V Ballast 347V Ballast AT Sensor/AAR Capacity Agency Approvals Physical Housing Dimensions Color Environmental Operating Storage CU120A 120V AC, 60 Hz. 24V DC, 100mA. CU230A 230V AC, 50/60 Hz. 24V DC, 100mA. CU277A 277V AC, 60 Hz. 24V DC, 100mA. CU347A 347V AC, 60 Hz. 24V DC, 100mA. 0 to 1800 watts. 0 to 2400 watts. NA NA NA 1 to 3 combined. UL Listed, cUL Certified. NA NA 0 to 3680 watts. NA NA 1 to 3 combined. UL Listed, cUL Certified. NA NA NA 0 to 5540 watts. NA 1 to 3 combined. UL Listed, cUL Certified. NA NA NA NA 0 to 5205 watts. 1 to 3 combined. UL Listed, cUL Certified. All CU Series Control Units Flame retardant UL 94-5V plastic. 3.69”L x 2.33”W x 1.36”H. Black. 32° F to 104° F (0° C to 40° C); 0% to 90% noncondensing relative humidity. -20° F to 150° F (-29° C to 65° C); 0% to 90% noncondensing relative humidity. Add-A-Relay AAR Electrical Power Input Load Capacity Incandescent 120V Ballast 230V Ballast 277V Ballast 347V Ballast Agency Approvals 0 to 1800 watts. 0 to 2400 watts. 0 to 3680 watts. 0 to 5540 watts. 0 to 5205 watts. UL Listed. Physical Housing Dimensions Color Flame retardant UL 94-5V plastic. 3.69” L x 2.33” W x 1.36” H. Black. Environmental Operating 32° F to 104° F (0° C to 40° C); 0% to 90% noncondensing relative humidity. -20° F to 150° F (-29° C to 65° C); 0% to 90% noncondensing relative humidity. Specifications Storage 24V DC nominal, 33mA from Hubbell CU series control unit. D-18 www.hubbell-wiring.com Dimensions in Inches (mm) Occupancy Sensors H-MOSS® Occupancy Sensors Wiring Schematics Ceiling and Wall Mount Sensors Adaptive Dual Technology, Ultrasonic, and Passive Infrared Ceiling and Wall Mount Sensors ATD, ATU and ATP Series Ceiling and Wall Mount Sensors Single Circuit Application: 1 to 3 sensors wired to control unit with optional override off switch. Single Circuit Application: Two control units wired in parallel to operate 4 to 6 sensors in a single zone. Maximum 3 sensors per control unit. (Any sensor will activate lighting.) CU Series Control Unit (Specify Voltage) CU Series Control Unit (Specify Voltage) Switch* Red Blk Blue Red Red Red Red Blk Blue Red Blk Red Red Blue White Blue Red Red (+24V) Black Blue Black Blk White N H Blk Red Black Blue Black Blue N H ATD, ATU and ATP Series Sensors** Lighting Load White Lighting Load Blue Black ATD, ATU and ATP Series Sensors** CU Series Control Unit (Specify Voltage) Red White Red Blue Red Blk Two Circuit Application: 1 to 2 sensors wired to control unit and Add-A-Relay (control unit switches circuit 1, Add-A-Relay switches circuit 2). Blue White Red Red (+24V) Black Blue Black Blk * Optional Override Off Switch Lighting Load CU Series Control Unit (Specify Voltage) Two Circuit Application: Two control units wired in two circuits to operate 3 to 6 sensors in a single zone. Maximum 3 sensors per control unit. (Any sensor will activate both lighting loads.) CU Series Control Unit (Specify Voltage) N H White Blue Red AAR Add-A-Relay Circuit 2 N H Red Red Red (+24V) Black Blue Black Blk Lighting Load Blue Circuit 1 Red ATD, ATU and ATP Series Sensors** Blk Red Red Blk Blue Red Blue White Red Red Black Blue Black Blk Circuit 1 N H Red Black Blue Red Lighting Load Blue White Dimensions in Inches (mm) Red Blk Red Blue Blue Red Red White Blk Red (+24V) Black Blue Black **NOTE: For wiring sensors with isolated relay and photocell option (models with "RP" suffix): Photocell Option: Cap off Blue sensor wire. Connect Grey sensor wire to Blue control unit wire. Isolated Relay Option: Common-Blue/White wire, Normally Closed-Black/White wire, Normally OpenYellow/White wire. Wiring Schematics CU Series Control Unit (Specify Voltage) Circuit 2 N H Lighting Load Black ATD, ATU and ATP Series Sensors** Red Lighting Load White www.hubbell-wiring.com D-19 Occupancy Sensors H-MOSS® Occupancy Sensors Wiring Schematics Ceiling and Wall Mount Sensors Adaptive Technology Dual, Ultrasonic, and Passive Infrared Ceiling and Wall Mount Sensors. ATD, ATU and ATP Series Ceiling and Wall Mount Sensors Single Circuit, Dual Level Switching Application: 1 to 3 sensors wired to control unit with optional override off switches. Single Circuit, 3-Way Switching Application: 1 to 3 sensors wired to control unit with optional override off switches. Traveler Traveler Single Pole Switch Red Blk Red Blue Blk Blue Single Pole Switch Red Red CU Series Control Unit (Specify Voltage) Red Red Blk Blue Red Red Blk Black Blue Blue Lighting Load Blue Inboard Ballast Red Outboard Ballast CU Series Control Unit (Specify Voltage) Blk 3-Way Switch 3-Way Switch Red Black White White Red Red Blk Black Blue Blue Black White White ATD, ATU and ATP Series Sensors** H N ATD, ATU and ATP Series Sensors** Multi-Circuit Application: 1 to 3 sensors wired to control unit that is wired to a multi-pole lighting contactor. N H Single Circuit, 4-Way Switching Application: 1 to 3 sensors wired to control unit with optional override off switches. Traveler Traveler 3-Way Switch Red Blk 4-Way Switch 3-Way Switch Traveler Blue CU Series Control Unit (Specify Voltage) Red Blue Wiring Schematics Lighting Load Red Blk Red Red Red Blk Black Blue Blue ATD, ATU and ATP Series Sensors** Black White White H N **NOTE: For wiring sensors with isolated relay and photocell option (models with "RP" suffix): Photocell Option: Cap off Blue sensor wire. Connect Grey sensor wire to Blue control unit wire. Isolated Relay Option: Common-Blue/White wire, Normally Closed-Black/White wire, Normally OpenYellow/White wire. D-20 www.hubbell-wiring.com Dimensions in Inches (mm)
ATD1000CRP 价格&库存

很抱歉,暂时无法提供与“ATD1000CRP”相匹配的价格&库存,您可以联系我们找货

免费人工找货