E59-M18C116D01-D1

E59-M18C116D01-D1

  • 厂商:

    EATON(伊顿)

  • 封装:

  • 描述:

  • 数据手册
  • 价格&库存
E59-M18C116D01-D1 数据手册
Inductive Proximity Sensors iProx 3.0 Introduction Quick Reference Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.1 3.2 Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.4 3.5 Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.6 3.7 3.8 V8-T3-55 Metal Face Sensors Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.9 V8-T3-58 High Current Output Sensors Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.10 V8-T3-62 Small Diameter (4, 5, 6.5, 8 mm) Sensors Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.11 V8-T3-65 3.12 3.13 V8-T3-86 E51 Modular Limit Switch Style Sensors Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V8-T3-88 E51 Limit Switch Style, Factory Sealed 6P+ Sensors Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 3 3 3 3 3 3 3 3 3 3 3 3 3 V8-T3-83 E55 Limit Switch Style Sensors with Nonmetallic Housings Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.16 V8-T3-79 E52 Rectangular Style Sensors Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.15 V8-T3-76 E52 Cube Style Sensors Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.14 V8-T3-71 Nonmetallic Tubular Sensors Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 3 E56 Pancake Sensors Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 3 V8-T3-49 Ferrous Only Tubular Sensors Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.17 V8-T3-35 AccuProx Analog Sensors Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E51, Factory Sealed V8-T3-29 E57 Two-Wire (AC, AC/DC, DC) Proximity Sensors AccuProx E52 Cube Style V8-T3-24 E57G General Purpose Proximity Sensors Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Nonmetallic Tubular V8-T3-18 E57PS Performance Short Body Sensors Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E56 Pancake V8-T3-11 E57P Performance Series Sensors 3.3 3 3 iProx Sensors Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E57P Performance V8-T3-2 V8-T3-97 Unless otherwise noted, the products contained in this section should not be used for functional safety applications. These products were not designed or tested to IEC 60947-5-3 or recommended for functional safety. 3 3 3 3 3 3 3 3 Learn Online For Customer Service in the U.S. call 1-877-ETN CARE (386-2273), in Canada call 1-800-268-3578. For Application Assistance in the U.S. and Canada call 1-800-426-9184. Volume 8—Sensing Solutions CA08100010E—July 2015 www.eaton.com V8-T3-1 3 3 3.0 Inductive Proximity Sensors Introduction 3 Quick Reference Guide 3 Inductive Proximity Sensors Sensing Application Sensing Style Size Max Range Product Family Page Shielded tubular 4 mm 0.8 mm Small Diameter Sensors V8-T3-65 3 5 mm 0.8 mm Small Diameter Sensors V8-T3-65 6.5 mm 1 mm Small Diameter Sensors V8-T3-65 3 8 mm 3 mm Small Diameter Sensors V8-T3-65 12 mm 4 mm iProx™ Sensors V8-T3-11 4 mm E57P Performance Sensors V8-T3-18, V8-T3-24 V8-T3-29 3 Shielded Sensor Target Mounting 3 3 18 mm 3 3 30 mm 3 Unshielded Sensor 3 Unshielded tubular 3 3 iProx Sensors V8-T3-11 8 mm E57P Performance Sensors V8-T3-18, V8-T3-24 8 mm E57G General Purpose Sensors V8-T3-29 15 mm iProx Sensors V8-T3-11 15 mm E57P Performance Sensors V8-T3-18, V8-T3-24 15 mm E57G General Purpose Sensors V8-T3-29 6.5 mm 2 mm Small Diameter V8-T3-65 8 mm 6 mm Small Diameter V8-T3-65 12mm 10 mm iProx Sensors V8-T3-11 8 mm E57P Performance Sensors V8-T3-18, V8-T3-24 8 mm E57G General Purpose Sensors V8-T3-29 18 mm iProx Sensors V8-T3-11 12 mm E57P Performance Sensors V8-T3-18, V8-T3-24 V8-T3-29 18 mm 3 3 30 mm 3 3 3 E57G General Purpose Sensors Mounting Target 12 mm E57G General Purpose Sensors 29 mm iProx Sensors V8-T3-11 22 mm E57P Performance Sensors V8-T3-18, V8-T3-24 22 mm E57G General Purpose Sensors V8-T3-29 12 mm 8 mm AccuProx™ Analog Sensors V8-T3-49 18 mm 15 mm AccuProx Analog Sensors V8-T3-49 30 mm 25 mm AccuProx Analog Sensors V8-T3-49 Shielded cube 40 x 40 x 40 mm 20 mm E52 Cube Style Sensors V8-T3-79 Unshielded cube 40 x 40 x 40 mm 40 mm E52 Cube Style Sensors V8-T3-79 Analog tubular 3 4 mm 8 mm Analog Sensor Target 3 3 Shielded Sensor 3 3 Target Mounting 3 Unshielded Sensor 3 3 Target Mounting 3 3 3 3 V8-T3-2 Volume 8—Sensing Solutions CA08100010E—July 2015 www.eaton.com Inductive Proximity Sensors Introduction 3.0 Inductive Proximity Sensors, continued Sensing Application Target Sensing Style Size Max Range Product Family Page 3 Shielded limit switch 118 x 40 x 40 mm 114 x 39 x 38.4 mm 13 mm E51 Modular Limit Switch Style Sensors E51 Limit Switch Style, Factory Sealed 6P+ Sensors E55 Limit Switch Style Sensors with Nonmetallic Housings V8-T3-88, V8-T3-97 3 Mounting 3 3 3 Shielded Sensor Unshielded limit switch Target 118 x 40 x 40 mm 114 x 39 x 38.4 mm 24 mm E51 Series E55 Series V8-T3-88, V8-T3-97 Mounting 3 3 3 Unshielded Sensor Target 3 Shielded Sensor Shielded pancake 79 x 79 x 39 mm 40 mm E56 Series V8-T3-71 3 3 3 3 Mounting Unshielded pancake Target Unshielded Sensor 79 x 79 x 39 mm 110 x 110 x 41 mm 171.5 x 171.5 x 67.5 mm 100 mm E56 Series V8-T3-71 3 3 3 3 Mounting 3 3 3 3 3 3 3 3 3 3 3 3 3 Volume 8—Sensing Solutions CA08100010E—July 2015 www.eaton.com V8-T3-3 3.0 Inductive Proximity Sensors Introduction 3 Technical Reference 3 Inductive Proximity Sensors 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 General There are a number of factors which should be considered when applying induction proximity sensors. A detailed discussion of these factors can be found on Page V8-T12-4. Presented below are a few of the more important considerations for quick reference. Mounting Inductive proximity sensors are available in two classifications: shielded (also known as embeddable or flush mountable) and unshielded (non-embeddable or non-flush mountable). What these terms refer to is the distance to surrounding metal that the device can be mounted. In the case of a shielded sensor the device can be mounted with the sensor completely surrounded by metal. In the case of an unshielded sensor, a metal free zone must be provided when mounting the sensor. The size of the metal free zone is dependent on both the size of the sensor and the type of sensing range it has, for example, standard or extended. When mounting the sensors, do not exceed the following recommended torque specifications. Mounting Ranges a d b Torque Specifications Stainless Steel 12 mm Diameter Shielding a b Standard Range 3 Shielded 0 0 Unshielded 2 x Sn Cap height Semi-shielded Sn d Non-embeddable 2 x Sn Cap height 3 3 3 V8-T3-4 Volume 8—Sensing Solutions CA08100010E—July 2015 www.eaton.com 70 lb-in (7.9 Nm) 20 lb-in (2.3 Nm) 70 lb-in (7.9 Nm) 30 mm Diameter 70 lb-in (7.9 Nm) Where a and b are the metal free dimensions. 3 35 lb-in (4.0 Nm) 18 mm Diameter Extended Range 3 Nickel-Plated Brass 70 lb-in (7.9 Nm) Inductive Proximity Sensors Introduction 3.0 Extended Range Sensors 3 Extended range proximity sensors by Eaton’s Electrical Sector offer sensing distances almost three times greater than conventional devices. They are available in semi-shielded designs: mounted similar to an embeddable sensor—and non-embeddable designs requiring more metal free zone area than conventional unshielded sensors. All are available in a variety of circuits and terminations. 3 3 Target Material When manufacturers of inductive proximity sensors state the sensing range of their devices, they are usually based upon a ferrous target made of carbon-rolled steel (IE FE 360) defined by ISO630. For example, in this product guide the E57P-18SPN5-C2 has a sensing range of 5 mm based upon a target of mild steel. Sensing ranges to targets made of non-ferrous metals have to have a correction factor applied as listed in the table below. To use this table, multiply the sensing distance of the device by the factor given. 3 Example: The E57P-18SPN5-C2 has a sensing range of 5 mm. When used to sense a brass target, the sensing range becomes 2.25 mm (5 mm x 0.45). 3 3 3 3 3 3 Table of Correction Factors Multiply sensing range of device by factor given below. 3 Correction Factors 3 Target Sensor Size 4–8 mm 12 mm 18 mm 30 mm Limit Switch Stainless steel 400 0.90 0.90 1.0 1.0 1.0 Stainless steel 300 0.65 0.70 0.70 0.75 0.85 Brass 0.35 0.45 0.45 0.45 0.5 Aluminum 0.35 0.40 0.45 0.40 0.47 Copper 0.30 0.25 0.35 0.30 0.40 3 3 3 3 Target Size Often overlooked when applying sensors is the fact that the manufacturer’s stated sensing ranges are also dependent upon target size. The table below reflects the standard target sizes which were used to determine sensing ranges. If targets are the same size or greater than standard, no reduction in sensing distance will occur. However, a smaller target size will result in a decrease in sensing range. 3 A general rule of thumb is that the target size shall be three times the range or the size of the sensor face, whichever is larger. 3 3 3 3 Standard Target Size 1 Target Standard Sensing Range Shielded Devices Unshielded Devices 3 Extended Sensing Range Semi-Shield Devices Non-Embeddable Devices 4 mm 4 mm square 4 mm square — — 5 mm 5 mm square 5 mm square — — 6.5 mm 6.5 mm square 6.5 mm square — — 8 mm 8 mm square 8 mm square — — 12 mm 12 mm square 12 mm square 18 mm square 30 mm square 18 mm 18 mm square 24 mm square 36 mm square 60 mm square 30 mm 30 mm square 45 mm square 66 mm square — Limit switch 45 mm square 72 mm square — — 3 3 3 3 3 Note 1 Targets are 1 mm thick. 3 3 3 Volume 8—Sensing Solutions CA08100010E—July 2015 www.eaton.com V8-T3-5 3.0 Inductive Proximity Sensors Introduction 3 Product Selection Guide 3 iProx E57P Performance Series E57PS Performance Short Body E57G General Purpose Page V8-T3-11 Page V8-T3-18 Page V8-T3-24 Page V8-T3-29 Overview Overview Overview Overview Designed to be the highest performing tubular inductive sensor. Standard features include extended sensing ranges, high noise-immunity, extreme durability and includes Autoconfigure Technology. Advanced features include output delay, speed detection and cloning with ProxView Software. High performance inductive sensors. Extended and standard ranges available. High performance inductive sensors with the ability to fit into tighter spaces. This full-line, tubular proximity sensor family provides a cost-effective solution for high volume OEM use. Applications Applications Applications Applications Automotive, machine tool, material handling where high sensing performance and inventory consolidation is a priority. Automotive, machine tool, material handling where high sensing performance and inventory consolidation is a priority. Automotive, machine tool, material handling where high sensing performance and inventory consolidation is a priority. Machine tool detection, press applications, cam detection, material handling, valve and shaft position, automotive assembly. Product Features Product Features Product Features Product Features Auto-configure technology automatically detects a sinking (NPN) or sourcing (PNP) connection and switches the sensor accordingly, without any user intervention Optional computer programming cable and Windows-based ProxView configuration software makes it easy to customize sensors Clone the sensor to match the characteristics of more than 4,800 competitive models, or configure it to match your specific application needs Advanced programmable features such as dual outputs, output delay, speed detection and more 12, 18 and 30 mm diameters Three-wire DC sensors 360° LED indicators standard NO or NC outputs Short-circuit protection Resettable short-circuit protected and reverse polarity on select models Robust stainless steel tubes, shockresistant front caps, polycarbonate end bells, and impact-absorbing potting compound are resistant to physical and environmental abuse in high temperature, high pressure washdown and high shock and vibration applications 12, 18 and 30 mm diameters Three-wire DC sensors 360° LED indicators standard NO or NC outputs Short-circuit protection Resettable short-circuit protected and reverse polarity on select models Robust stainless steel tubes, shockresistant front caps, polycarbonate end bells, and impact-absorbing potting compound are resistant to physical and environmental abuse in high temperature, high pressure washdown and high shock and vibration applications 12, 18 and 30 mm diameters Three-wire DC sensors 360° LED indicators standard NO or NC outputs Short-circuit protection Resettable short-circuit protected and reverse polarity on select models Robust stainless steel tubes, shockresistant front caps, polycarbonate end bells, and impact-absorbing potting compound are resistant to physical and environmental abuse in high temperature, high pressure washdown and high shock and vibration applications Technical Data and Specifications Technical Data and Specifications Technical Data and Specifications Technical Data and Specifications Current ratings— AC: 250 mA DC: 300 mA Enclosure ratings— NEMA® 4, 4X, 6, 6P, 12, 13 IEC IP67, IP69K Construction— Stainless steel Current ratings— DC: 300 mA Enclosure ratings—IP67, IP69K; NEMA 4, 4X, 6, 6P Construction— Stainless steel housing and nuts Current ratings— DC: 300 mA Enclosure ratings—IP67, IP69K; NEMA 4, 4X, 6, 6P Construction— Stainless steel housing and nuts Current ratings— DC: 100 mA Enclosure ratings—IP67; NEMA 4, 4X, 6, 6P Construction— Stainless steel housing and nickel-brass nuts Approvals Approvals Approvals Approvals cUL® Listed CE cULus Listed CE cULus Listed CE cULus Listed 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 V8-T3-6 Volume 8—Sensing Solutions CA08100010E—July 2015 www.eaton.com Inductive Proximity Sensors Introduction E57 Two-Wire (AC, AC/DC, DC) Proximity AccuProx Ferrous Only Tubular 3.0 3 Metal Face 3 3 3 3 Page V8-T3-35 Page V8-T3-49 Page V8-T3-55 Page V8-T3-58 Overview Overview Overview Overview 3 Various models available in two-wire configurations: Stainless steel (AC, AC/DC) Stainless steel short body (AC, AC/DC) Nickel-brass (AC, DC) AccuProx sensors feature analog outputs that change linearly as the target moves closer or further from the sensor face. Sensors designed to detect only ferrous metals (steel/iron). Tough sensors with thick stainless steel sensing faces and barrels. 3 Applications Applications Applications Applications Machine tool detection, press applications, cam detection, material handling, valve and shaft position, automotive assembly. Part positioning, distance, size and thickness measurement, general inspection and error proofing (such as material imperfection or blemish detection), eccentricity or absolute angle detection, identification of different metals Workcell applications, automotive and aircraft production. Metal cutting operations where damage to sensor face could occur. Product Features Product Features Product Features Product Features 12, 18 and 30 mm diameters Two-wire AC, AC/DC, DC Shielded and unshielded models Standard and extended ranges LED indicators Cable and micro-connector NO or NC outputs Extended linear sensing range of up to 25 mm—three times longer than standard tubular analog inductive sensors Outputs available in current (4–20 or 0–20 mA) and voltage (0–10 V) High output resolution and repeatability for applications requiring precision sensing performance Robust stainless steel barrel, shockresistant front cap, polycarbonate end bell and impact-absorbing potting compound Ideal for extreme temperature or high pressure washdown environments 18 mm diameters Two-wire AC or three-wire DC NO or NC outputs Micro- and mini-pin terminations LED indicators 12, 18 and 30 mm diameters Two-wire AC or three-wire DC 20 mil thick stainless steel face 303 stainless steel barrel LED indicator 2-meter cable, micro- and mini-pin connections Technical Data and Specifications Technical Data and Specifications Technical Data and Specifications Technical Data and Specifications Stainless steel: Current ratings— 500 mA maximum Enclosure ratings—IP67, IP69K; NEMA 4, 4X, 6, 6P, 12, 13 Current ratings— 0–10 Vdc, 0–20 mA, 4–20 mA Enclosure ratings— NEMA 4, 4X, 6, 6P, 13 Construction— Stainless steel Current ratings— AC: 500 mA continuous DC: 200 mA continuous Enclosure ratings— NEMA 4, 4X, 6, 6P, 12, 13 IEC IP67 Construction— Stainless steel Current ratings— AC: 500 mA continuous DC: 200 mA continuous Enclosure ratings— NEMA 4, 4X, 6, 6P, 12, 13 IEC IP67 Construction— Stainless steel Nickel-Brass: Current ratings— 200 mA (AC); 100 mA (DC) Enclosure ratings— IP69K, IP67 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 Approvals Approvals Approvals Approvals 3 cULus (Stainless Steel) cCSAus (Nickel-Brass) CE (SS: AC/DC only, NiBr: DC only) cUL Listed UL Listed CSA Certified UL Listed CSA Certified 3 3 3 3 3 Volume 8—Sensing Solutions CA08100010E—July 2015 www.eaton.com V8-T3-7 3.0 3 Inductive Proximity Sensors Introduction High Current Output Ferrous Only Tubular Small Diameter E56 Pancake Page V8-T3-62 Page V8-T3-55 Page V8-T3-65 Page V8-T3-71 Overview Overview Overview Overview DC sensors which can carry extremely large continuous inrush current. Sensors designed to detect only ferrous metals (steel/iron). Small diameter and short body (4, 5, 6.5 and 8 mm) tubular housings for tight sensing applications. Self-contained sensors capable of sensing up to 3.94 inches (100 mm). Applications Applications Applications Applications Heavy-duty vehicles, cement mixers, lift trucks, front end loaders, farm equipment. Workcell applications, automotive and aircraft production Automation equipment, robotics, machine tool, counting, sorting Oil rig operations, floor conveyors, automotive assembly, overhead cranes Product Features Product Features Product Features Product Features 30 mm diameter stainless steel housing Solid-state output for 12 ampere continuous, 50 ampere inrush capacity –40° to 158°F (–40° to 70°C) temperature range NO and NC isolated outputs Heavy gauge SJO cable 18 mm diameters Two-wire AC or three-wire DC NO or NC outputs Micro- and mini-pin terminations LED indicators Variety of diameters in stainless steel housings PVC cable, micro- and nano-pin connections LED indicators standard Short overall lengths Short circuit and reverse polarity protection 40, 50, 70 and 100 mm sensing distances Four-wire DC models have complementary outputs (1 NO/1 NC) Four-wire DC models use auto-configure technology, which allows the sensor to automatically adapt for NPN or PNP without user intervention Available in two-wire AC versions Power and output LED indicator Quick disconnect option Short-circuit protected in DC Longest sensing distances available Technical Data and Specifications Technical Data and Specifications Technical Data and Specifications Technical Data and Specifications Current ratings— Varies by model Enclosure ratings— NEMA 4, 4X, 6, 6P, 12, 13 IEC IP67 Construction— Stainless steel Current ratings— AC: 500 mA continuous DC: 200 mA continuous Enclosure ratings— NEMA 4, 4X, 6, 6P, 12, 13 IEC IP67 Construction— Stainless steel Current ratings— DC: 200 mA maximum Enclosure ratings— NEMA 4, 4X, 6, 6P, 12, 13 IEC IP67 Construction— Stainless steel Current ratings— AC: 500 mA continuous DC: 200 mA continuous Enclosure ratings— NEMA 4, 4X, 12, 13 (some models also rated NEMA 6) IEC IP66 Construction— PPS Approvals Approvals Approvals Approvals — UL Listed CSA Certified CE cULus Listed 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 V8-T3-8 Volume 8—Sensing Solutions CA08100010E—July 2015 www.eaton.com Inductive Proximity Sensors Introduction Tubular, Nonmetallic Housing E52 Cube Style 3.0 3 E52 Rectangular Style 3 3 3 3 3 3 Page V8-T3-76 Page V8-T3-79 Page V8-T3-83 Overview Overview Overview Tubular sensors with nonmetallic housings offer high corrosion resistance. A family of industry-standard, cube-sized inductive sensors with long range capabilities. A variety of small rectangular sensors for limited space applications. Applications Applications Applications 3 Food processing lines, high washdown environments Automotive, manufacturing, machinery OEMs Tight applications where conventional sensor are too large 3 Product Features Product Features Product Features 3 12, 18 and 30 mm diameters shielded and unshielded sensing Normally open or closed outputs AC and DC voltages Tough ABS plastic housing Output LED on all models Long inductive proximity ranges available (up to 40 mm sensing distance) Four-wire DC models have complementary outputs (1 NO/1 NC) Four-wire DC models use auto-configure technology, which allows the sensor to automatically adapt for NPN or PNP without user intervention Robust design featuring vibration and impact-absorbing potting compound Ideal for extreme temperatures or high pressure washdown environments Variety of housing styles R12, R18, Q16, Q25 10 to 30 Vdc NPN and PNP output Short-circuit protection LED indicator for output status Technical Data and Specifications Technical Data and Specifications Technical Data and Specifications Current ratings— AC: 150 mA DC: 200 mA Enclosure ratings— NEMA 3, 3S, 4, 4X, 13 IEC IP66 Construction— ABS plastic Current ratings— DC: 300 mA maximum Enclosure ratings— NEMA 4, 4X, 6, 6P, 12, 13 IEC IP67 Construction— Zinc alloy/PPS, PL Current ratings— DC: 100 mA maximum Enclosure ratings— NEMA 1, 2, 3, 3S, 4, 12 IEC IP66 Construction— PBT composition housing 3 3 3 3 3 3 3 3 3 3 3 3 3 Approvals Approvals Approvals — cULus Listed — 3 3 3 3 3 3 3 Volume 8—Sensing Solutions CA08100010E—July 2015 www.eaton.com V8-T3-9 3.0 Inductive Proximity Sensors Introduction E55 Limit Switch Style, Nonmetallic Housing E51 Limit Switch Style, Factory Sealed 6P + E51 Limit Switch Style, Modular Page V8-T3-86 Page V8-T3-88 Page V8-T3-97 Overview Overview Overview 3 These nonmetallic sensors provide corrosion resistance in a limit switch style housing. 3 Completely epoxy filled in unitized, one piece limit switch style construction for reliable performance under the most adverse of environmental conditions. Modular design allows maximum use of inventories in these limit switch style housings. Solid-state circuitry in a variety of sensing ranges. Applications Applications Applications 3 Food processing lines, high washdown environments All corrosive environments: Coolants/ cutting oils, automotive applications Machine tool, punch presses, automotive, conveyor systems 3 Product Features Product Features Product Features 5 position head can be top mounted or in any of four side positions Long sensing ranges up to 40 mm Normally open or closed outputs AC voltages Tough PBT resin housing One piece housing on switch body/ receptacle Head and housing totally epoxy encapsulated Side sensing head can be unfastened and moved to any of four positions Quick disconnect options Corrosive resistant epoxy coated housing Modular heads, switch bodies, receptacles Shielded or unshielded sensing ranges Solid-state electronics Viton gasket seals LED indicators for power and output status Top and side sensing heads Alternate frequency for side by side operation Components individually labeled for easy identification Technical Data and Specifications Technical Data and Specifications Technical Data and Specifications Current ratings— AC: 400 mA Enclosure ratings— NEMA 4, 4X, 6, 12, 13 IEC IP67 Construction— PBT resin Current ratings— AC: 1 ampere continuous DC: 0.6 ampere continuous Enclosure ratings— NEMA 3, 3S, 4, 4X, 6, 6P, 12, 13 IEC IP67 Construction— Die cast zinc Gasket material: Viton® Current ratings— AC: 1 ampere continuous DC: 0.6 ampere continuous Enclosure ratings— NEMA 3, 3S, 4, 4X, 6, 6P, 12, 13 IEC IP67 Class I, Class II, Division 2 Groups A, B, C, D, F and G; Class III Construction— Die cast zinc Gasket material: Viton Approvals Approvals Approvals — cUL Listed UL Listed CSA Certified (most models) 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 V8-T3-10 Volume 8—Sensing Solutions CA08100010E—July 2015 www.eaton.com Inductive Proximity Sensors iProx Sensors 3.1 Contents iProx Sensors Description Page iProx Sensors Product Selection iProx Sensors . . . . . . . . . . . . . . . . . . . . . . . Complementary and Dual Output Sensors . Compatible Connector Cables . . . . . . . . . . . Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . Technical Data and Specifications . . . . . . . . . . Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . V8-T3-12 V8-T3-14 V8-T3-15 V8-T3-15 V8-T3-16 V8-T3-17 V8-T3-17 3 3 3 3 3 3 3 3 3 3 3 iProx Sensors Product Description The iProx represents the highest performance, most versatile tubular inductive sensor offered by Eaton’s Electrical Sector. By utilizing an embedded microprocessor and exclusive SmartSense™ technology, iProx can sense up to three times farther than typical sensors of its class, while providing an unheard-of level of customization. Both shielded and unshielded versions of iProx feature extended sensing ranges. This allows the sensor to be mounted farther from the target, thereby reducing the potential for target impacts and increasing the sensing reliability of your application. The iProx also includes a wide range of advanced features that can be enabled via optional programming tools. Using the ProxView Windows-based software package, an entirely custom sensor can be programmed to perfectly fit an application. ● Sensor characteristics, such as sensing range, can be customized down to the nearest tenth of a millimeter. Outputs can be changed from NO to NC. The iProx even features built-in timing delays and speed detection logic— no PLC programming is necessary. With extended sensing range, quality construction and the ability to adapt to its environment, iProx is the ideal choice for even the most demanding inductive sensing applications. ● Application Description Typical Applications ● Automotive ● Machine tool ● Material handling ● Metalworking ● ● ● Features ● For the most current information on this product, visit our Web site: www.eaton.com ● Available in AC two-wire, DC three-wire and unique DC four-wire with complementary (NO-NC) or dual NO outputs Reliably detect metal targets at up to three times the range of conventional shielded or unshielded tubular inductive sensors ● Quality construction using a stainless steel barrel, 360-degree dual-color LED indicator, Ryton® impact-resistant face cap and vibration-absorbing potting compound Auto-configure technology automatically detects a sinking (NPN) or sourcing (PNP) connection and switches the sensor accordingly, without any user intervention Exclusive SmartSense embedded microprocessor technology allows for customizable range, band sensing, nuisance metal rejection, timing delays and over/under speed detection Optional computer programming cable and Windows-based ProxView configuration software makes it easy to customize sensors Withstands high electrical noise (up to 20 V/m) Resistant to extreme temperatures (–40 °F [–40 °C]) Standards and Certifications ● ● cUL Listed CE 3 3 3 3 3 DANGER THIS SENSOR IS NOT A SAFETY DEVICE AND IS NOT INTENDED TO BE USED AS A SAFETY DEVICE. This sensor is designed only to detect and read certain data in an electronic manner and perform no use apart from that, specifically no safetyrelated use. This sensor product does not include self-checking redundant circuitry, and the failure of this sensor product could cause either an energized or de-energized output condition, which could result in death, serious bodily injury, or property damage. 3 3 3 3 3 3 3 3 3 3 3 3 For Customer Service in the U.S. call 1-877-ETN CARE (386-2273), in Canada call 1-800-268-3578. For Application Assistance in the U.S. and Canada call 1-800-426-9184. Volume 8—Sensing Solutions CA08100010E—July 2015 www.eaton.com V8-T3-11 3 3 3.1 Inductive Proximity Sensors iProx Sensors 3 Product Selection 3 iProx Sensors 3 Note: Custom iProx models can also be ordered directly from the factory with pre-set ranges, outputs and connectors. Consult the Eaton Application Engineers at 1-800-426-9184 for more information. Two-Wire Sensors 3 3 Operating Voltage Standard Range 3 Sensing Range Shielding Connection Type 1 Shielded 3-pin micro AC connector NO Output Catalog Number 2 NC Output Catalog Number 2 E59-M12A105A01-A1 E59-M12A105A01-A2 12 mm Diameter 20–132 Vac 4 mm 3 E59-M12A105A01P-A1 E59-M12A105A01P-A2 3-pin mini AC pigtail 3 E59-M12A105A01PB-A1 E59-M12A105A01PB-A2 2-meter cable E59-M12A105C02-A1 E59-M12A105C02-A2 3-pin micro AC connector E59-M12C110A01-A1 E59-M12C110A01-A2 3 3-pin micro AC pigtail 3 E59-M12C110A01P-A1 E59-M12C110A01P-A2 3-pin mini AC pigtail 3 E59-M12C110A01PB-A1 E59-M12C110A01PB-A2 3 2-meter cable E59-M12C110C02-A1 E59-M12C110C02-A2 3 3 3-pin micro AC pigtail Extended Range 10 mm Standard Range 3 Unshielded 18 mm Diameter 3-pin micro AC connector E59-M18A109A01-A1 E59-M18A109A01-A2 3 3-pin micro AC pigtail 3 E59-M18A109A01P-A1 E59-M18A109A01P-A2 3-pin mini AC pigtail 3 E59-M18A109A01PB-A1 E59-M18A109A01PB-A2 3 2-meter cable E59-M18A109C02-A1 E59-M18A109C02-A2 3-pin micro AC connector E59-M18C118A01-A1 E59-M18C118A01-A2 3 3-pin micro AC pigtail 3 E59-M18C118A01P-A1 E59-M18C118A01P-A2 3 3-pin mini AC pigtail 3 E59-M18C118A01PB-A1 E59-M18C118A01PB-A2 2-meter cable E59-M18C118C02-A1 E59-M18C118C02-A2 3-pin micro AC connector E59-M30A115A01-A1 E59-M30A115A01-A2 3 3-pin micro AC pigtail 3 E59-M30A115A01P-A1 E59-M30A115A01P-A2 3 E59-M30A115A01PB-A1 E59-M30A115A01PB-A2 2-meter cable E59-M30A115C02-A1 E59-M30A115C02-A2 3-pin micro AC connector E59-M30C129A01-A1 E59-M30C129A01-A2 3-pin micro AC pigtail 3 E59-M30C129A01P-A1 E59-M30C129A01P-A2 3-pin mini AC pigtail 3 E59-M30C129A01PB-A1 E59-M30C129A01PB-A2 2-meter cable E59-M30C129C02-A1 E59-M30C129C02-A2 3 3 20–132 Vac 8 mm Shielded Extended Range 18 mm Standard Range Unshielded 30 mm Diameter 20–132 Vac 15 mm Shielded 3-pin mini AC pigtail 3 Extended Range 29 mm 3 3 Unshielded Notes See listing of compatible connector cables on Page V8-T3-15. 3 1 3 2 3 For sensors with custom cable lengths or PUR jackets, contact Application Engineering at 1-800-426-9184. Sensors are ordered with pre-set outputs from the factory, but can be later programmed either NO or NC using the ProxView software. Standard pigtail cable length is 12 in. 3 3 3 3 3 3 3 V8-T3-12 Volume 8—Sensing Solutions CA08100010E—July 2015 www.eaton.com Inductive Proximity Sensors iProx Sensors 3.1 Note: Custom iProx models can also be ordered directly from the factory with pre-set ranges, outputs and connectors. Consult the Eaton Application Engineers at 1-800-426-9184 for more information. 3 3 Three-Wire Sensors Operating Voltage Standard Range Sensing Range Shielding Connection Type 1 NO Output Catalog Number 2 Shielded 4-pin micro DC connector E59-M12A105D01-D1 E59-M12A105D01-D2 4-pin micro DC pigtail 3 E59-M12A105D01P-D1 E59-M12A105D01P-D2 2-meter cable E59-M12A105C02-D1 E59-M12A105C02-D2 4-pin micro DC connector E59-M12C110D01-D1 E59-M12C110D01-D2 4-pin micro DC pigtail 3 E59-M12C110D01P-D1 E59-M12C110D01P-D2 2-meter cable E59-M12C110C02-D1 E59-M12C110C02-D2 4-pin micro DC connector E59-M18A108D01-D1 E59-M18A108D01-D2 3 4-pin micro DC pigtail 3 E59-M18A108D01P-D1 E59-M18A108D01P-D2 3 2-meter cable E59-M18A108C02-D1 E59-M18A108C02-D2 4-pin micro DC connector E59-M18C116D01-D1 E59-M18C116D01-D2 4-pin micro DC pigtail 3 E59-M18C116D01P-D1 E59-M18C116D01P-D2 2-meter cable E59-M18C116C02-D1 E59-M18C116C02-D2 4-pin micro DC connector E59-M30A115D01-D1 E59-M30A115D01-D2 3 4-pin micro DC pigtail 3 E59-M30A115D01P-D1 E59-M30A115D01P-D2 3 2-meter cable E59-M30A115C02-D1 E59-M30A115C02-D2 3 4-pin micro DC connector E59-M30C129D01-D1 E59-M30C129D01-D2 3 E59-M30C129D01P-D1 E59-M30C129D01P-D2 E59-M30C129C02-D1 E59-M30C129C02-D2 3 3 12 mm Diameter 6–48 Vdc 4 mm Extended Range 10 mm Standard Range NC Output Catalog Number 2 Unshielded 3 3 3 3 3 18 mm Diameter 6–48 Vdc 8 mm Shielded 3 Extended Range 18 mm Standard Range Unshielded 3 3 30 mm Diameter 6–48 Vdc Extended Range 15 mm 29 mm Shielded Unshielded 4-pin micro DC pigtail 2-meter cable 3 3 Notes See listing of compatible connector cables on Page V8-T3-15. 1 2 3 3 For sensors with custom cable lengths or PUR jackets, contact Application Engineering at 1-800-426-9184. Sensors are ordered with pre-set outputs from the factory, but can be later programmed either NO or NC using the ProxView software. Standard pigtail cable length is 12 in. 3 3 3 3 3 3 3 3 3 3 Volume 8—Sensing Solutions CA08100010E—July 2015 www.eaton.com V8-T3-13 3.1 3 Inductive Proximity Sensors iProx Sensors Complementary and Dual Output Sensors 3 Four-Wire Sensors 3 Operating Voltage 3 Standard Range Sensing Range Shielding Output Type Shielded NPN (sinking) 6–48 Vdc 4 mm PNP (sourcing) Extended Range 10 mm 3 Unshielded NPN (sinking) PNP (sourcing) 3 3 Standard Range 6–48 Vdc 8 mm Shielded NPN (sinking) PNP (sourcing) Extended Range 3 18 mm Unshielded 3 3 15 mm Shielded 3 NPN (sinking) PNP (sourcing) Extended Range 29 mm 3 Unshielded NPN (sinking) PNP (sourcing) 3 3 E59-M12A105D01-D3NN E59-M12A105C02-D3NN E59-M12A105C02-D1NN 4-pin micro DC connector E59-M12A105D01-D3PP E59-M12A105D01-D1PP 2-meter cable E59-M12A105C02-D3PP E59-M12A105C02-D1PP 4-pin micro DC connector E59-M12C110D01-D3NN E59-M12C110D01-D1NN 2-meter cable E59-M12C110C02-D3NN E59-M12C110C02-D1NN 4-pin micro DC connector E59-M12C110D01-D3PP E59-M12C110D01-D1PP 2-meter cable E59-M12C110C02-D3PP E59-M12C110C02-D1PP E59-M18A108D01-D1NN 4-pin micro DC connector E59-M18A108D01-D3NN 2-meter cable E59-M18A108C02-D3NN E59-M18A108C02-D1NN 4-pin micro DC connector E59-M18A108D01-D3PP E59-M18A108D01-D1PP 2-meter cable E59-M18A108C02-D3PP E59-M18A108C02-D1PP 4-pin micro DC connector E59-M18C116D01-D3NN E59-M18C116D01-D1NN 2-meter cable E59-M18C116C02-D3NN E59-M18C116C02-D1NN 4-pin micro DC connector E59-M18C116D01-D3PP E59-M18C116D01-D1PP 2-meter cable E59-M18C116C02-D3PP E59-M18C116C02-D1PP 30 mm Diameter 6–48 Vdc 3 3 NPN (sinking) PNP (sourcing) Standard Range E59-M12A105D01-D1NN 4-pin micro DC connector 2-meter cable 18 mm Diameter 3 3 Dual NO Output Catalog Number 1 12 mm Diameter 3 3 Connection Type Complementary Output (1NO-1NC) Catalog Number 4-pin micro DC connector E59-M30A115D01-D3NN E59-M30A115D01-D1NN 2-meter cable E59-M30A115C02-D3NN E59-M30A115C02-D1NN 4-pin micro DC connector E59-M30A115D01-D3PP E59-M30A115D01-D1PP 2-meter cable E59-M30A115C02-D3PP E59-M30A115C02-D1PP 4-pin micro DC connector E59-M30C129D01-D3NN E59-M30C129D01-D1NN 2-meter cable E59-M30C129C02-D3NN E59-M30C129C02-D1NN 4-pin micro DC connector E59-M30C129D01-D3PP E59-M30C129D01-D1PP 2-meter cable E59-M30C129C02-D3PP E59-M30C129C02-D1PP Notes See listing of compatible connector cables on Page V8-T3-15. 3 1 At this time, iProx Complementary and Dual Output models are not available with auto-sink/source detection. Therefore, PNP (sourcing) and NPN (sinking) models must be ordered separately. 3 3 3 3 3 3 3 3 3 V8-T3-14 Volume 8—Sensing Solutions CA08100010E—July 2015 www.eaton.com Inductive Proximity Sensors iProx Sensors 3.1 Compatible Connector Cables 3 Standard Cables 1 Current Rating Voltage at 600 V Style Micro-Style Straight Female Gauge Length 3-pin, 3-wire 22 AWG 6.0 ft (2m) 4-pin, 4-wire 22 AWG Pin Configuration/Wire Colors (Face View Female Shown) PVC Jacket Catalog Number PUR Jacket Catalog Number CSAS3F3CY2202 CSAS3F3RY2202 CSDS4A4CY2202 CSDS4A4RY2202 Micro-Style, Straight Female — — Mini-Style Straight Female Number of Pins AC DC 1-Green 2-Red/Black 3-Red/White 6.0 ft (2m) 1-Brown 2-White 3-Blue 4-Black 13 A — 3-pin 16 AWG 6 ft (2m) 1-Green 2-Black 3-White 3 3 3 3 3 Catalog Number Mini-Style, Straight Female 3 3 CSMS3F3CY1602 3 3 3 Accessories 3 iProx Sensors Software Description Catalog Number Step-by-step programming software required to program iProx. Compatible with Microsoft Windows® and Windows® Mobile devices. E59SW1 3 3 3 3 Cable The iProx programming cable is used to program individual iProx sensors, providing a connection between the computer and the sensor. Connects to computer via a serial (RS-232) or USB port. (USB connection requires an adapter which is included with purchase.) E59RP1 Field applied labels for iProx sensor (100 pcs) E59LABEL 3 3 3 Labels 3 3 3 Note 1 For a full selection of connector cables, see Tab 10, section 10.1. 3 3 3 3 3 3 3 3 Volume 8—Sensing Solutions CA08100010E—July 2015 www.eaton.com V8-T3-15 3.1 3 Inductive Proximity Sensors iProx Sensors iProx Starter Kits Starter Kit Description 3 Catalog Number Interested in custom programming iProx sensors to fit your application? These kits include everything needed to get the most out of iProx: a sensor, a programming cable (E59RP1), a micro connector cable (CSDS4A4CY2202) and ProxView software on CD-ROM (E59SW1). 3 Starter kit includes: 3 12 mm AC unshielded iProx sensor (E59-M12C110A01-A1) E5912ACKIT 12 mm DC unshielded iProx sensor (E59-M12C110D01-D1) E5912DCKIT 3 18 mm AC unshielded iProx sensor (E59-M18C118A01-A1) E5918ACKIT 3 18 mm DC unshielded iProx sensor (E59-M18C116D01-D1) E5918DCKIT 30 mm AC unshielded iProx sensor (E59-M30C129A01-A1) E5930ACKIT 30 mm DC unshielded iProx sensor (E59-M30C129D01-D1) E5930DCKIT 3 3 Technical Data and Specifications 3 iProx Sensors 3 Description Two-Wire Sensors Three-Wire Sensors Input voltage 20–132 Vac 6–48 Vdc 3 Load current 250 mA 300 mA Leakage current ≤1.7 mA at 32 °F (0 °C), 2.0 mA at –40 °F (–40 °C) ≤150 μA 3 Voltage drop 20 V/m) 3 Notes 3 1 3 3 Ryton® is a registered trademark of Phillips Chemical (division of Phillips Petroleum). 2 Our products conform to NEMA® tests as indicated, however, some severe washdown applications can exceed these NEMA test specifications. iProx sensors may be programmed to perform in side by side or high noise immunity applications using the iProx programming cable (E59RP1) and ProxView software (E59SW1). Use the side by side response time parameter when using the iProx Tray Programmer (E59TP1), iProx programming cable (E59RP1) and ProxView software (E59SW1). 3 3 3 3 V8-T3-16 Volume 8—Sensing Solutions CA08100010E—July 2015 www.eaton.com 3.1 Inductive Proximity Sensors iProx Sensors Wiring Diagrams Pin numbers are for reference, rely on pin location when wiring. 3 iProx Sensors 3 Operating Voltage 3 Connector Models (Face View Male Shown) Output Cable Models Micro Mini 3 Two-Wire Sensors 20–132 Vac NO and NC BN L1 BU L2 L2 Load Load 3 L2 or (–) Load L1 or +V L1 3 Three-Wire Sensors 6–48 Vdc 2 NO and NC (NPN and PNP) 1 2 BN BK +V (–) Load BU 3 — +V Load 3 Load (–) 3 Four-Wire Dual Output and Complementary Sensors 6–48 Vdc NO and NC (NPN) 3 BN WH BU BL 3 NO and NC (PNP) BN WH BU BL 3 3 — Load +V 3 +V Load (–) (-) Load 3 Load 3 +V Load Load 3 — +V (–) Load 3 (–) Load 3 3 Dimensions 3 Approximate Dimensions in Inches (mm) Micro-Connector Models Cable Models 3 3 3 C B A Size Shielding 12 mm Shielded 2.46 (62.4) 1.98 (50.3) Unshielded 2.46 (62.4) 1.64 (41.6) 18 mm 30 mm A 3 D C B D A B C Size Shielding 0.02 (0.5) 0.67 (17) 12 mm Shielded 2.71 (68.7) 1.98 (50.3) 0.02 (0.5) 0.67 (17) 0.36 (9) 0.67 (17) Unshielded 2.71 (68.7) 1.64 (41.6) 0.36 (9) 0.67 (17) Shielded 2.54 (64.5) 2.00 (50.9) 0.02 (0.5) 0.94 (24) Unshielded 2.54 (64.5) 1.47 (37.4) 0.55 (14) 0.94 (24) Shielded 2.74 (69.6) 2.13 (54.1) 0.03 (0.75) 1.41 (36) Unshielded 2.74 (69.6) 1.41 (35.8) 0.75 (19) 1.41 (36) 18 mm 30 mm A B C 3 D D Shielded 2.73 (69.3) 2.00 (50.9) 0.02 (0.5) 0.94 (24) Unshielded 2.73 (69.3) 1.47 (37.4) 0.55 (14) 0.94 (24) Shielded 2.92 (74.1) 2.13 (54.1) 0.03 (0.75) 1.41 (36) Unshielded 2.92 (74.1) 1.41 (35.8) 0.75 (19) 1.41 (36) Notes 1 The three-wire DC version of iProx automatically configures itself to NPN or PNP based on field wiring. No user intervention is required. 2 Pin numbers 2 and 4 are internally jumpered together. Either pin may be used. 3 The complementary (1NO-1NC) output models feature the NC output on pin 2 (white). 3 3 3 3 3 3 3 3 Volume 8—Sensing Solutions CA08100010E—July 2015 www.eaton.com V8-T3-17 3.2 3 Inductive Proximity Sensors E57P Performance Series Sensors Contents E57P Performance Series Sensors Description 3 Page E57P Performance Series Sensors Product Selection E57P Performance Sensors . . . . . . . . . . . . Compatible Connector Cables . . . . . . . . . . Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . Technical Data and Specifications . . . . . . . . . . Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 3 3 3 V8-T3-19 V8-T3-20 V8-T3-20 V8-T3-21 V8-T3-22 V8-T3-23 3 3 3 3 3 E57P Performance Series Sensors 3 Product Description Features For sensing applications requiring more demanding specifications, the new E57P Performance series incorporates premium features without the premium price. With its stainless steel tubular body, IP69K rating, wide temperature range (down to –40 °C), fast switching speed and laser-etched markings, the E57P series provides value at a low price point. ● 3 3 3 3 3 3 ● ● ● ● ● ● ● 360° LED indicator Stainless steel tube 10–48 Vdc operating voltage Short-circuit protection –40 to 70 °C temperature range IP69K environmental rating Durable laser-engraved label Available in cable and micro-connector styles Standards and Certifications ● ● cULus Listed CE 3 3 3 DANGER THIS SENSOR IS NOT A SAFETY DEVICE AND IS NOT INTENDED TO BE USED AS A SAFETY DEVICE. This sensor is designed only to detect and read certain data in an electronic manner and perform no use apart from that, specifically no safetyrelated use. This sensor product does not include self-checking redundant circuitry, and the failure of this sensor product could cause either an energized or de-energized output condition, which could result in death, serious bodily injury, or property damage. 3 3 3 3 3 3 3 3 3 For the most current information on this product, visit our Web site: www.eaton.com V8-T3-18 For Customer Service in the U.S. call 1-877-ETN CARE (386-2273), in Canada call 1-800-268-3578. For Application Assistance in the U.S. and Canada call 1-800-426-9184. Volume 8—Sensing Solutions CA08100010E—July 2015 www.eaton.com 3.2 Inductive Proximity Sensors E57P Performance Series Sensors Product Selection 3 E57P Performance Sensors 3 Three-Wire Sensors Operating Voltage 12 mm Sensing Range (Sn) Connection Type 1 NO Output Catalog Number NC Output Catalog Number Shielded (PNP) 2-meter cable E57P-12SPN2-C2 E57P-12SPC2-C2 4-pin micro DC connector E57P-12SPN2-Q E57P-12SPC2-Q Shielded (NPN) 2-meter cable E57P-12SNN2-C2 E57P-12SNC2-C2 4-pin micro DC connector E57P-12SNN2-Q E57P-12SNC2-Q Unshielded (PNP) 2-meter cable E57P-12UPN4-C2 E57P-12UPC4-C2 4-pin micro DC connector E57P-12UPN4-Q E57P-12UPC4-Q Unshielded (NPN) 2-meter cable E57P-12UNN4-C2 E57P-12UNC4-C2 4-pin micro DC connector E57P-12UNN4-Q E57P-12UNC4-Q Shielded (PNP) 2-meter cable E57P-12SPN4-C2 E57P-12SPC4-C2 4-pin micro DC connector E57P-12SPN4-Q E57P-12SPC4-Q Shielded (NPN) 2-meter cable E57P-12SNN4-C2 E57P-12SNC4-C2 4-pin micro DC connector E57P-12SNN4-Q E57P-12SNC4-Q Unshielded (PNP) 2-meter cable E57P-12UPN8-C2 E57P-12UPC8-C2 4-pin micro DC connector E57P-12UPN8-Q E57P-12UPC8-Q Unshielded (NPN) 2-meter cable E57P-12UNN8-C2 E57P-12UNC8-C2 4-pin micro DC connector E57P-12UNN8-Q E57P-12UNC8-Q 3 Shielded (PNP) 2-meter cable E57P-18SPN5-C2 E57P-18SPC5-C2 3 4-pin micro DC connector E57P-18SPN5-Q E57P-18SPC5-Q Shielded (NPN) 2-meter cable E57P-18SNN5-C2 E57P-18SNC5-C2 4-pin micro DC connector E57P-18SNN5-Q E57P-18SNC5-Q Unshielded (PNP) 2-meter cable E57P-18UPN8-C2 E57P-18UPC8-C2 4-pin micro DC connector E57P-18UPN8-Q E57P-18UPC8-Q Unshielded (NPN) 2-meter cable E57P-18UNN8-C2 E57P-18UNC8-C2 4-pin micro DC connector E57P-18UNN8-Q E57P-18UNC8-Q Shielded (PNP) 2-meter cable E57P-18SPN8-C2 E57P-18SPC8-C2 4-pin micro DC connector E57P-18SPN8-Q E57P-18SPC8-Q Shielded (NPN) 2-meter cable E57P-18SNN8-C2 E57P-18SNC8-C2 4-pin micro DC connector E57P-18SNN8-Q E57P-18SNC8-Q Unshielded (PNP) 2-meter cable E57P-18UPN12-C2 E57P-18UPC12-C2 4-pin micro DC connector E57P-18UPN12-Q E57P-18UPC12-Q Unshielded (NPN) 2-meter cable E57P-18UNN12-C2 E57P-18UNC12-C2 4-pin micro DC connector E57P-18UNN12-Q E57P-18UNC12-Q 3 12 mm Diameter End Sensing 10–48 Vdc 2 mm (standard range) 4 mm (standard range) 4 mm (extended range) 8 mm (extended range) 18 mm 3 Shielding 3 3 3 3 3 3 3 3 18 mm Diameter End Sensing 10–48 Vdc 5 mm (standard range) 8 mm (standard range) 8 mm (extended range) 12 mm (extended range) 3 3 3 3 3 3 3 3 3 Notes See listing of compatible connector cables on Page V8-T3-20. 3 1 3 For cable lengths longer than 2 meters, add the number of the desired length in meters to the end of the listed catalog number (for catalog numbers ending with a number, add an S and then the length). Examples for a 5-meter cable: E57-18LE12-A becomes E57-18LE12-A5; E57LAL12A2 becomes E57LAL12A2S5. 3 3 3 3 3 Volume 8—Sensing Solutions CA08100010E—July 2015 www.eaton.com V8-T3-19 3.2 E57P Performance Series Sensors Three-Wire Sensors, continued 3 3 Inductive Proximity Sensors Operating Voltage 30 mm 3 Sensing Range (Sn) Shielding Connection Type 1 NO Output Catalog Number Shielded (PNP) 2-meter cable E57P-30SPN10-C2 E57P-30SPC10-C2 4-pin micro DC connector E57P-30SPN10-Q E57P-30SPC10-Q Shielded (NPN) 2-meter cable E57P-30SNN10-C2 E57P-30SNC10-C2 4-pin micro DC connector E57P-30SNN10-Q E57P-30SNC10-Q Unshielded (PNP) 2-meter cable E57P-30UPN15-C2 E57P-30UPC15-C2 4-pin micro DC connector E57P-30UPN15-Q E57P-30UPC15-Q Unshielded (NPN) 2-meter cable E57P-30UNN15-C2 E57P-30UNC15-C2 4-pin micro DC connector E57P-30UNN15-Q E57P-30UNC15-Q Shielded (PNP) 2-meter cable E57P-30SPN15-C2 E57P-30SPC15-C2 4-pin micro DC connector E57P-30SPN15-Q E57P-30SPC15-Q Shielded (NPN) 2-meter cable E57P-30SNN15-C2 E57P-30SNC15-C2 4-pin micro DC connector E57P-30SNN15-Q E57P-30SNC15-Q Unshielded (PNP) 2-meter cable E57P-30UPN22-C2 E57P-30UPC22-C2 4-pin micro DC connector E57P-30UPN22-Q E57P-30UPC22-Q Unshielded (NPN) 2-meter cable E57P-30UNN22-C2 E57P-30UNC22-C2 4-pin micro DC connector E57P-30UNN22-Q E57P-30UNC22-Q 30 mm Diameter End Sensing 10–48 Vdc 10 mm (standard range) 3 3 15 mm (standard range) 3 3 15 mm (extended range) 3 3 3 22 mm (extended range) 3 3 3 Compatible Connector Cables 3 Standard Cables 1 Current Rating Voltage at 600 V Style 3 3 NC Output Catalog Number Micro-Style Straight Female Number of Pins Gauge Length 22 AWG 6.0 ft (2m) Pin Configuration/Wire Colors (Face View Female Shown) PVC Jacket Catalog Number PUR Jacket Catalog Number CSDS4A4CY2202 CSDS4A4RY2202 Micro-Style, Straight Female — DC 3 4-pin, 4-wire 1-Brown 2-White 3-Blue 4-Black 3 3 3 Accessories E57P Performance Sensors 3 3 3 3 Description Reference Mounting brackets See Tab 8, section 8.2 Replacement mounting nuts and other accessories See Tab 8, section 8.3 Connector cables See Tab 10, section 10.1 Notes See listing of compatible connector cables on Page V8-T3-20. 3 1 3 2 For cable lengths longer than 2 meters, add the number of the desired length in meters to the end of the listed catalog number (for catalog numbers ending with a number, add an S and then the length). Examples for a 5-meter cable: E57-18LE12-A becomes E57-18LE12-A5; E57LAL12A2 becomes E57LAL12A2S5. For a full selection of connector cables, see Tab 10, section 10.1. 3 3 3 3 V8-T3-20 Volume 8—Sensing Solutions CA08100010E—July 2015 www.eaton.com Inductive Proximity Sensors E57P Performance Series Sensors 3.2 Technical Data and Specifications 3 E57P Performance Sensors Description 3 Performance Three-Wire DC Sensors 3 Operating voltage 10–48 Vdc Output current (continuous) 300 mA Switching frequency [Hz] Standard range: 12 mm—Shielded: 2000; Unshielded: 2000 18 mm—Shielded: 1200; Unshielded: 1200 30 mm—Shielded: 600; Unshielded: 500 Extended range: 12 mm—Shielded: 1200; Unshielded: 500 18 mm—Shielded: 300; Unshielded: 300 30 mm—Shielded: 400; Unshielded: 200 Leakage current
E59-M18C116D01-D1 价格&库存

很抱歉,暂时无法提供与“E59-M18C116D01-D1”相匹配的价格&库存,您可以联系我们找货

免费人工找货