Technical Data 2016
Effective May 2017
Supersedes February 2009
GDC
5 mm x 20 mm Time-delay glass tube fuses
Agency information
• cURus Recognition: Guide JDYX2/JDYX8, File
E19180
• IMQ Approval: File E1921, CA03.00530
• MITI/JET: File JET1641-31003-1005
Ordering
•
•
Product features
Time-delay, low breaking capacity
Optional axial leads available
5 x 20mm physical size
Glass tube, nickel-plated brass endcap
construction
• Designed to IEC 60127-2 (32mA-10A)
•
•
•
•
Product Code
GDC-32mA
GDC-40mA
GDC-50mA
GDC-63mA
GDC-80mA
GDC-100mA
GDC-125mA
GDC-160mA
GDC-200mA
GDC-250mA
GDC-315mA
GDC-400mA
GDC-500mA
GDC-630mA
GDC-800mA
GDC-1A
GDC-1.25A
GDC-1.6A
GDC-2A
GDC-2.5A
GDC-3.15A
GDC-4A
GDC-5A
GDC-6.3A
Voltage Interrupting Rating (amps)
Rating
at Rated Voltage (50Hz)
Vac
Vac
250
35
250
35
250
35
250
35
250
35
250
35
250
35
250
35
250
35
250
35
250
35
250
35
250
35
250
35
250
35
250
35
250
35
250
35
250
35
250
35
250
35
250
40
250
50
250
63
Specify packaging, product, and option code
With TR2 packaging code, lead wire length is 19.05mm
Electrical Characteristics
2.1 In
2.75 In
4 In
10 In
In
max min max min max
min max
32mA-100mA 2 min 200 ms 10 sec 40 ms 3 sec 10 ms 300 ms
125mA-6.3A 2 min 600 ms 10 sec 150 ms 3 sec 20 ms 300 ms
Specifications
Typical DC
Cold Resistance
(Ω)*
21.0
13.90
9.24
6.96
4.42
2.80
1.97
1.27
1.00
0.640
0.450
0.31
0.183
0.186
0.129
0.0757
0.060
0.0425
0.03325
0.0255
0.0185
0.0139
0.00985
0.0071
* DC Cold Resistance (measured at
很抱歉,暂时无法提供与“BK/GDC-1A”相匹配的价格&库存,您可以联系我们找货