0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
44H30-04-1-06N

44H30-04-1-06N

  • 厂商:

    GRAYHILLINC.

  • 封装:

  • 描述:

    SWITCH ROTARY 125 DEG;C, 30 DEG

  • 详情介绍
  • 数据手册
  • 价格&库存
44H30-04-1-06N 数据手册
Multi-Deck Rotary Switches SERIES 42, 43, 44 and 54 1" Diameter, 1 Amp, Standard, Military SR04 Features • Rugged Construction Ensures Switch Operation for the Life of Your Equipment • Many Circuitry Options • MIL Qualified Versions MIL-S-3786/04 • Features Choice Include: Shaft/ Panel Seal, Adjustable Stops, PC Termination, UL Recognized DIMENSIONS in inches (and millimeters) Standard, UL Recognized and Military Qualified Solder Lug Styles Rear Views Series 42 1.015 ± .015 (25,78 ± 0,38) DIA. OVER TERMINALS #1 THREAD .064 (1,63) MIN. DIA. HOLE AFTER PLATING Series 44 .250 + .001 –.002 (6,35 + 0,03 –0,05) DIA. 1.170 ± .015 (29,72 ± 0,38) DIA. OVER TERMINALS GRAyHILL 6 1 7 15° 5 3/8-32 UNEF-2A THREAD (MTG. HOLE = 3/8 DIA. MIN.) 9 10 12 11 8 BUSHING KEyWAy .066 ± .002 (1,68 ± 0,05) WIDE By .036 ± .003 (0,91 ± 0,08) DEEP FROM A .375 (9,53) DIA. NON-TURN TAB .125 ± .003 (3,18 ± 0,08) WIDE By .031 ± .003 (0,79 ± 0,08) THICK 3 INTEGRAL ASSEMBLy NUT, DO NOT REMOVE C L OF BUSHING KEyWAy SEE NOTE 4 DIM. C ± .015 (0,38) GRAyHILL 10 1 36° 2 DIM. B REF. STUD PROJECTION 3 DIM. F ± .015 (0,38) 7 8 9 4 2 Rotary Switches .250 ± .020 (6,35 ± 0,51) DIM. A + .046 –.020 (+ 0,05 –0,51) 5 .437 ± .020 (11,10 ± 0,51) DIM. E ± .010 (0,25) .219 ± .005 (5,56 ± 0,13) .437 ± .020 (11,10 ± 0,51) 6 DIM. D ± .010 (0,25) DIA. OF NON-TURN C L .375 TAB ± .015 (9,53 ± 0,38) 30° Note: Common location for a single pole per deck switch. For common location on multi-pole switches, see circuit diagrams. .064 (1,63) MIN. DIA. HOLE AFTER PLATING For rear view of 45°, 60° and 90°, see circuit diagram. No. of Decks 1 2 3 4 5 6 Dimension A 1.025 (26,04) 1.371 (34,82) 1.717 (43,61) 2.063 (52,40) 2.409 (61,19) 3.005 (76,33) Dimension B Approx. Weight No. Dimension B Style Style Grams of Dimension Style Style A M or H 42 44 Decks A A M or H .062 (1,57) .062 (1,57) .062 (1,57) .062 (1,57) .062 (1,57) .312 (7,92) .030 (0,76) .030 (0,76) .030 (0,76) .030 (0,76) .030 (0,76) .280 (7,11) 40.0 45.5 51.0 56.5 62.0 67.5 Grayhill part number and date code marked on detent cover label. Customer part number marked on request. Military part number marked when required. UL recognized markings as required. Grayhill, Inc. • 561 Hillgrove Avenue • LaGrange, Illinois 48 7 3.351 (85,16) 55 8 3.697 (93,90) 62 9 4.043 (102,69) 69 10 4.389 (111,48) 76 11 4.735 (120,27) 83 12 5.081 (129,06) Dimension Series 42 Series 44 C .312 (7,92) .312 (7,92) .312 (7,92) .312 (7,92) .312 (7,92) .312 (7,92) D .280 (7,11) .280 (7,11) .280 (7,11) .280 (7,11) .280 (7,11) .280 (7,11) E Approx. Weight Grams 42 44 73.0 78.5 84.0 89.5 95.0 100.5 90 97 104 111 118 125 F .562 (14,27) 1.000 (25,4) .830 (21,08) .093 (2,36) .642 (16,31) 1.162 (29,51) 1.000 (25,4) .121 (3,07) 60525-5997 • USA • Phone: 708-354-1040 • Fax: 708-354-2820 • www.grayhill.com Multi-Deck Rotary Switches CIRCUIT DIAGRAMS: Solder Lug Terminals Switch is Viewed From Shaft End and Shown in Position No. 1 Note: All common terminals are located above base terminals as shown. 10 12 C1 1 6 4 C L 1 C1 6 5 2 C2 C3 9 C4 10 11 7 8 C4 12 C L 1 C1 6 5 4 3 C5 9 10 7 6 2 C3 FOUR POLE C L OF BUSHING KEyWAy 9 8 6 5 10 1 5 4 3 C2 1 2 C L C1 FIVE OR SIX POLE Rear Views C4 7 6 C2 8 4 CL 1 C1 8 4 1 2 3 7 C3 5 CL C1 15° 2 3 C2 45° TWO POLE THREE OR FOUR POLE 6 4 3 3 2 CL 1 C1 C2 2 15° 3 1 5 6 4 C L 1 C1 C1 3 5 6 4 C2 4 C3 5 6 C L OF BUSHING KEyWAy 2 ONE POLE 6 4 5 2 7 6 5 1 C6 2 60° TWO POLE THREE POLE C L OF BUSHING KEyWAy 4 4 C2 3 3 C L 1 C1 C1 1 15° 3 Series 44 90° Angle of Throw 4 GRAyHILL ONE POLE 1 2 2 2 ONE POLE TWO POLE Grayhill, Inc. • 561 Hillgrove Avenue • LaGrange, Illinois 90° 60525-5997 • USA • Phone: 708-354-1040 • Fax: 708-354-2820 • www.grayhill.com Rotary Switches C L OF BUSHING KEyWAy C1 Series 44 60° Angle of Throw 2 C1 C1 2 TWO POLE 4 5 3 4 CL 9 3 5 1 8 4 8 3 6 10 C L 2 7 6 7 6 5 C1 ONE POLE Series 44 45° Angle of Throw C2 1 4 3 12 C2 5 11 12 C2 Series 42 & 43 36° Angle of Throw 11 TWO POLE THREE POLE THREE POLE Styles A, D and S Styles M, MS, H and HS 8 7 C3 7 2 3 4 10 GRAyHILL ONE POLE 3 12 9 GRAyHILL 5 2 3 8 11 8 4 10 7 C L 1 C1 6 C3 9 1 5 8 11 C2 7 12 7 9 8 1 Series 44 & 54 30° Angle of Throw C L OF BUSHING 11 KEyWAy 2 8 10 3 9 Multi-Deck Rotary Switches SERIES 42 1" Diameter, 1 Amp, PC Mount Features • Satisfies High Current Board Level Applications • 36° Angle of Throw Permits up to Ten Positions • UL Recognized Versions DIMENSIONS in inches (and millimeters) DIM. A + .046 – .020 (+1,17 –0,00) C L C L C L .437 ± .020 (11,10 ± 0,51) .600 ± .031 (15,24 ± 0,79) .174 ± .010 (4,42 ± 0,25) .250 ± .020 (6,35 ± 0,51) #1 THREAD Termination One-sided termination is standard for switches with 2 to 5 positions per pole. Two-sided termination is standard for switches with 6 thru 10 positions per pole. 6 thru 10 positions per pole and terminals from one side of switch are available on special order. See Special Options, page F-10 or contact Grayhill. 10 1 9 8 C L OF BUSHING KEyWAy 2 3 C1 PC BOARD MOUNTING PATTERN CL OF FRONT SUPPORT PLATE MOUNTING HOLES .375 (9,53) TyP. .500 (12,7) TyP. .750 (19,05) .250 TyP. (6,35) TyP. 6 5 2 Standard Style CL OF BASE TERMINAL MOUNTING HOLES CL OF REAR SUPPORT PLATE MOUNTING HOLES CL COMMON TERMINAL MOUNTING HOLES .174 (4,42) TyP. .492 (12,50) 4 7 .110 (2,79) .174 (4,42) TyP. ONE POLE 1.470 ± .020 (37,34 ± 0,51) TYP. .250 ± .015 (6,35 ± 0,38) TYP. .187 ± .015 (4,75 ± 0,38) TYP. .735 ± .010 (18,67 ± 0,25) TYP. Shaft And panel seal: Srs. 42 & 44 Shown for a two deck switch SHAFT END Note: All common terminals are located above base terminals as shown. 3 5 Switch is Viewed From Shaft End and Shown in Position No. 1 3/8-32 UNEF-2A THREAD (MTG. HOLE=3/8 DIA. MIN.) 7 The Series 42/44 Styles, which include the letter "S" with the exception of style "HS", are watertight sealed to the mounting panel by utilizing the panel seal kit.These switches are built with a front plate that does not have a non-turn tab. The panel seal kit consists of a grooved hex nut, a keyed washer and a keyed panel seal. The grooved hex nut is assembled to the switch bushing. The keyed washer is slid down the bushing slot and seated into the hex nut groove. The seal is likewise assembled to the bushing and hex nut. The keyed washer is required to provide seal integrity in the bushing slot. When assembled to the panel, the grooved nut, backing washer and seal require the same space as a normal mounting nut. Hence, the seal kit does not alter the dimensions. Panel seal kit includes a non-turn washer to be used into a blind hole in the back panel. For panel seal kit part dimensions, see Accessories. Style "HS" switches use a similar sealing method, except the integral assembly nut retains the panel seal. All sealed style switches are provided with a shaft to bushing internal seal. adjustable stop switches: Series 42 and 44 5 3 4 T RS P FI TO S 3 Grayhill, Inc. • 561 Hillgrove Avenue • LaGrange, Illinois FI ST RST OP 4 6 7 5 9 11 The standard and UL recognized switches are also Equivalent Styles For style 44M30, use 44D30 initially available with adjustable stops. Two removable For style 42A36, use 42D36, For style 42U36, use 42UD36 stop washers allow you to limit the number of For style 44A30, use 44D30 For style 44U30, use 44UD30 For style 42M36, use 42D36 initially switch positions as needed. A knurled nut is supplied to secure the washers if desired. These switches have no bushing keyway. All other Front Views dimensions, ratings and characteristics are the 8 8 9 10 6 same as the standard fixed stop styles. Although not military qualified, the adjustable styles are useful in military equipment prototypes. However, USE OF KNURLED when submitting the equipment for government NUT IS OPTIONAL approval, the fixed stop qualified style should Series 42 Series 44 be substituted. 2 Rotary Switches C L OF BUSHING KEYWAY Grayhill part number and date code marked on detent cover label. Customer part number marked on request. UL recognized marking as required. COMMON LUG INTEGRAL ASSEMBLY NUT, DO NOT REMOVE BUSHING KEYWAY .066 ± .002 (1,68 ± 0,05) WIDE BY .036 ± .003 (0,91 ± 0,08) DEEP FROM A .375 (9,53) DIA. .500 ± .015 (12,7 ± 0,38) TYP. 10 8 .250 + .001 –.002 (6,35 + 0,03 –0,05) DIA. TERMINAL DIMENSIONS AT THIS POINT ARE .050 ± .005 (1,27 ± 0,13) WIDE BY .020 ± .003 (0,51 ± 0,08) THICK CIRCUIT DIAGRAM: PC Mount 1 9 .830 ± .010 (21,08 ± 0,25) .750 ± .010 (19,05 ± 0,25) TYP. .375 ± .015 (9,53 ± 0,38) TYP. .786 ± .010 (19,96 ± 0,25) DIA. GRAYHILL .219 ± .005 (5,56 ± 0,13) DIM. B REF. STUD PROJECTION .174 ± .010 (4,42 ± 0,25) 4 1.000 ± .010 (25,4 ± 0,25) DIA. 6 Standard Style ADJUSTABLE STOP WASHERS 60525-5997 • USA • Phone: 708-354-1040 • Fax: 708-354-2820 • www.grayhill.com Multi-Deck Rotary Switches SERIES 43 SERIES 54 1" Diameter, 1 Amp, Concentric Shafts Features • Two Switches in the Panel Space of a Single Shaft Rotary • Military Qualified Versions MIL-3786/04 • Choice of 10 Positions (Series 43) or 12 Positions (Series 54) DIMENSIONS in inches (and millimeters) Standard Style and Military Qualified Rear Views BUSHING KEyWAy .066 ± .002 (1,68 ± 0,05) WIDE By .036 ± .003 (0,91 ± 0,08) DEEP FROM A .375 (9,53) DIA. 3/8-32 UNEF-2A THREAD GRAyHILL 1.170 ± .015 (29,72 ± 0,38) DIA. OVER TERMINALS .030 (0,76) .030 (0,76) .280 (7,11) .030 (0,76) .280 (7,11) .280 (7,11) .280 (7,11) .280 (7,11) .280 (7,11) 48 54 60 54 60 66 60 66 72 60 67 74 67 74 81 74 81 88 15° 10 9 GRAyHILL .062 (1,57) .062 (1,57) .062 (1,57) .062 (1,57) .062 (1,57) .312 (7,92) .062 (1,57) .312 (7,92) .312 (7,92) 12 1.818 (46,18) 2.164 (54,97) 2.510 (63,75) 2.164 (54,97) 2.510 (63,75) 3.105 (78,87) 2.510 (63,75) 3.105 (78,87) 3.451 (87,66) 11 1 Series 54 2 Series 43 5 Style M or H 6 Style A 7 Style A, M or H 3 Approx. Weight Grams 8 1 1 1 2 2 2 3 3 3 Series 54 4 Number of Decks Dimension A Dimension B 1 2 3 1 2 3 1 2 3 10 MILITARy NUMBER MARKED ON ALL QUALIFIED SWITCHES INTEGRAL ASSEMBLy NUT, DO NOT REMOVE Note: Common location for a single pole per deck switch. For common location on multi-pole switches, see circuit diagrams. .064 (1,63) MIN. DIA. HOLE AFTER PLATING 30° .064 (1,63) MIN. DIA. HOLE AFTER PLATING Grayhill part number and date code marked on detent cover label. Customer part number marked on request. Military part number marked when required. Grayhill, Inc. • 561 Hillgrove Avenue • LaGrange, Illinois 60525-5997 • USA • Phone: 708-354-1040 • Fax: 708-354-2820 • www.grayhill.com Rotary Switches SEE NOTE Section Section “A” “B” 36° 4 C L OF BUSHING KEyWAy 7 8 9 SECTION SECTION A B CONTROLLED By .250 (6,35) .125 (3,18) DIA. SHAFT NON-TURN TAB .125 ± .003 (3,18 ± 0,08) WIDE By .031 ± .003 (0,79 ± 0,08) THICK #1 THREAD .830 (21,08) SER. 43 1.000 (25,4) SER. 54 ± .010 (0,25) .125 + .001 –.002 (3,18 + 0,03 –0,05) DIA. .250 + .001 –.002 (6,35 + 0,03 –0,05) DIA. 1.015 ± .015 (25,78 ± 0,38) OVER TERMINALS DIM. B REF. STUD PROJECTION 1 .093 ± .015 (2,36 ± 0,38) SER. 43 .121 ± .015 (3,07 ± 0,38) SER. 54 2 .250 ± .020 (6,35 ± 0,51) Series 43 5 .642 (16,31) SER. 54 .562 (14,27) SER. 43 ±.015(0,38) DIM. A + .046 –.020 (+0,05 –0,51) .375 ± .020 (9,53 ± 0,51) 6 .094 ± .004 (2,39 ± 0,10) .219 ± .005 (5,56 ± 0,13) .375 ± .020 (9,53 ± 0,51) 3 1.162 (29,51) DIA. SER. 54 1.000 (25,4) DIA. SER. 43 OF NON-TURN C L .375 TAB .250 ± .020 ± .015 (6,35 ± 0,51) (9,53 ± 0,25) .250 ± .020 (6,35 ± 0,51) Multi-Deck Rotary Switches SERIES 43 and 54 1" Diameter, 1 Amp, Add-A-Pot Features • Central Shaft Designed to Operate an Add-On Potentiometer • Potentiometer Mounting Plates Provided • Adjustable Stop Standard, Fixed Stop by Order • Choice of 10 Positions (Series 43) or 12 Positions (Series 54) DIMENSIONS In inches (and millimeters) Standard Style Rear Views Series 43 .375 ± .020 (9,53 ± 0,51) DIM. A + .046 –.020 (+0,05 –0,51) .375 ± .020 (9,53 ± 0,51) .625 ± .046 (15,88 ± 1,17) C OF NON-TURN .375 L TAB ± .015 (9,53 .250 ± .020 ± 0,38) (6,35 ± 0,51) .250 ± .020 (6,35 ± 0,51) 7 .140 ± .062 (3,56 ± 1,57) #1 THREAD 8 10 5 4 T RS FI TOP S 2 3 7 1 12 1 15° 2 60 67 74 3 9 4 48 54 60 10 5 .974 (24,74) 1.320 (33,53) 1.666 (42,32) 11 6 6 Approx. Weight Grams Dimension A Series 43 Series 54 7 F ST IRST OP 1 2 3 1.170 ± .015 (29,72 ± 0,38) OVER TERMINALS 8 11 5 Series 54 Note: Common location for a single pole per deck switch. For common location on multi-pole switches, see circuit diagrams. 30° 2 3 4 .642 ± .015 (16,31 ± 0,38) Two potentiometer mounting plates are supplied. Mounting plates have .261 (6,63) and .380 (9,65) diameter holes respectively for mounting potentiometers with 1/4" and 3/8" bushings. Additional nuts for the through bolts of the switch are provided for adjustment of mounting plate location. Tapered tongue on 1 /8" shaft provides coupling to screwdriver slots in potentiometer shafts. 2 3/8-32 UNEF-2A THREAD Number of Decks 10 4 USE OF KNURLED NUT OPTIONAL NON-TURN TAB .125 ± .003 (3,18 ± 0,08) WIDE By .031 ± .003 (0,79 ± 0,08) THICK 9 .064 (1,63) MIN. DIA. HOLE AFTER PLATING STOP WASHERS 1.162 ± .010 (29,51 ± 0,25) DIA. 5 36° SEE NOTE Series 54 6 .125 + .001 –.002 (3,18 + 0,03 –0,05) DIA. .250 + .001 –.002 (6,35 + 0,03 –0,05) DIA. 7 9 .830 (21,08) SER. 43 1.000 (25,4) SER. 54 ± .010 (0,25) 9 Rotary Switches .562 ± .015 (14,27 ± 0,38) 8 1.015 ± .015 (25,78 ± 0,38) OVER TERMINALS 8 6 .094 ± .004 (2,39 ± 0,10) .219 ± .005 (5,56 ± 0,13) Series 43 .093 ± .015 (2,36 ± 0,38) SER. 43 .121 ± .015 (3,07 ± 0,38) SER. 54 .250 ± .020 (6,35 ± 0,51) 3 1.000 ± .010 (25,4 ± 0,25) DIA. Plated brass spacers for ease of positioning mounting plate driving assembly are available on special request (sold only with switches). The use of spacers is recommended for other than prototype requirements. When ordering switches with spacers, give full details regarding special length, potentiometer being used, etc. Grayhill, Inc. • 561 Hillgrove Avenue • LaGrange, Illinois Standard style, concentric shaft, add-a-pot switches have adjustable stops. See Adjustable Stop description. Grayhill part number and date code marked on detent cover label. Customer part number marked on request. Military part number marked when required. 60525-5997 • USA • Phone: 708-354-1040 • Fax: 708-354-2820 • www.grayhill.com Multi-Deck Rotary Switches SERIES 54 1" Diameter, 1 Amp, Add-A-Pot Features • Military Qualified MIL-3786/04 • Central Shaft Designed to Operate MIL Potentiometer • Mounting Plate Options Provide Choice of Potentiometer • Fixed Distance from Switch to Mounting Plate DIMENSIONS In inches (and millimeters) Military Qualified Style DIM. A + .046 –.020 (+ 0,05 –0,51) .250 ± .020 (6,35 ± 0,51) .121 ± .015 (3,07 ± 0,38) .575 (14,61) REF. .140 ± .062 (3,56 ± 1,57) #1 THREAD 1.024 (26,01) 1.370 (34,80) 1.716 (43,59) 12 1 BUSHING KEyWAy .066 ± .002 (1,68 ± 0,05) WIDE By .036 ± .003 (0,91 ± 0,08) DEEP FROM A .375 (9,53) DIA. Potentiometer Mounting Approximate Weight Grams The two mounting plates shown below are supplied with each switch. 60 67 74 27.5 ±2 .245 ± .003 (6,22 ± 0,08) R. Series 54M Add-A-Pot Switch is a concentric shaft unit with provision for potentiometer mounting. Outer shaft operates switch decks. Inner shaft terminates in tapered tongue, which allows any desired potentiometer to be mounted.The Series 54M Add-A-Pot is qualified to MIL-DTL-3786/4-3. Patent No. 3,297,830. Grayhill part number and date code marked on detent cover label. Customer part number marked on request. Military part number marked when required. 30° .098 ± .003 (2,49 ± 0,08) DIA. (3) .130 ± .003 (3,30 ± 0,08) DIA. (2) .437 ± .003 (11,10 ± 0,08) R. 15 ± 2 .380 ± .003 (9,65 ± 0,08) DIA. (1) THROUGH BOLT HOLE (2 EA.) 15 ±2 1.265 (32,13) DIA. Grayhill, Inc. • 561 Hillgrove Avenue • LaGrange, Illinois Mounting Plate A .261 ± .003 (6,63 ± 0,08) DIA. (1) .375 ± .003 (9,53 ± 0,08) R. 9 ±2 1.265 (32,13) DIA. .531 ± .003 (13,49 ± 0,08) R. Mounting Plate B 60525-5997 • USA • Phone: 708-354-1040 • Fax: 708-354-2820 • www.grayhill.com Rotary Switches 1 2 3 SEE POTENTIOMETER MOUNTING INTEGRAL ASSEMBLy NUT, DO NOT REMOVE 3/8-32 NEF-2A THREAD Note: Common locations for a single pole per deck switch. For common location on multiple switches, see circuit diagram. 15° GRAyHILL OR CUSTOMER PART NUMBER MARKED ON SWITCH COVER UPON REQUEST. MILITARy NUMBER MARKED ON ALL QUALIFIED SWITCHES NON-TURN TAB .125 ± .003 (3,18 ± 0,08) WIDE By .031 ± .003 (0,79 ± 0,08) THICK Number of Dimension Decks A 9 6 .018 ± .005 (0,46 ± 0,13) .052 ± .005 (1,32 ± 0,13) 10 7 .642 ± .015 (16,31 ± 0,38) 11 8 .219 ± .005 (5,56 ± 0,13) 1.000 ± .010 (25,4 ± 0,25) 2 (6,35 ± 0,51) .125 + .001 –.002 (3,18 + 0,03 –0,05) DIA. .250 + .001 –.002 (6,35 + 0,03 –0,05) DIA. 1.170 ± .015 (29,72 ± 0,38) OVER TERMINALS 3 .375 ± .020 (9,53 ± 0,51) 4 .375 ± .020 (9,53 ± 0,51) 5 1.162 ± .010 (29,51 ± 0,25) DIA. C L OF NON-TURN TAB .375 ± .015 (9,53 ± 0,38) .250 ± .020 Multi-Deck Rotary Switches Military Qualified Single Shaft Switches The military styles of the single shaft Series 42 and 44 rotary switches are qualified to MILDTL-3786/4, specifically SR04-1. Qualification includes two temperature ranges. Unsealed styles M, MB, MG and MBG are qualified for -65 to 85°C. Unsealed styles H, HB, HG and HBG, plus sealed styles HS, HBS, HGS and HBGS are qualified for -65°C to 125°C. Qualification includes low level switching and shaft grounding as specified in MIL-DTL-3786. Qualification includes 30°, 36°, 45°, 60° and 90° angles of throw with solder lug terminals. The military styles are dimensionally the same as the standard styles with two exceptions. The location of the common for the 3-pole switch differs (see circuit diagrams) and the non-turn tab for styles HS, HBS, HGS and HBGS differs per the Shaft and Panel Seal description following. Two Switches, Concentric Shafts The M style of the concentric shaft Series 43 and 54 switches is qualified to MIL-DTL-3786/4, specifically SR04-2. Unsealed switches are qualified for -65°C to 85°C in 30°, 36°, 45°, 60° and 90° throws. The standard and military styles of the concentric switches have the same dimensions with the exception of the location of the 3 pole common (see circuit diagrams). The 30° and 36° throws are described in the ordering information. If the 45°, 60° and 90° throws are required, they can be provided in Section A of the Series 54 Rotary Switches; see Standard Options, page J-9. Add-A-Pot Switches The military style of the add-a-pot Series 54 switch is qualified to MIL-DTL-3786/4, specifically SR04-3. These unsealed switches are qualified for -65°C to 85°C in 30°, 45°, 60° and 90° throws. The dimensions of the military style add-a-pot switches are not the same as the standard adda-pot switches; see drawings. All Qualified Switches Complete electrical ratings and characteristics for all of these qualified switches are listed on the following pages. Standard variations such as terminals, shaft and/or bushing length etc., which do not affect performance, can be marked as qualified product. Adjustable stops cannot be qualified. Contact Grayhill for details about variations. Military qualified switches may be ordered by the military M number listed in MIL-DTL-3786/4 or by the Grayhill part number. They will be marked to specifications. Military Qualified Shaft and Panel Seal: Styles HS, HBS, HGS and HBGS The shaft is sealed to the bushing by an internal O-ring per MIL-P-5516B. The bushing is sealed to the panel with a silicone rubber washer and a stainless steel backing washer. The combined uncompressed thickness is 0.055" (1,40). Since this switch has a flat cover, a non-turn washer is supplied (see Panel Seal Kit). If using it, mount it in front of the panel. Specifications: Electrical Ratings Rotary Switches 115 Vac resistive 6-28 Vdc resistive 115 Vac inductive 115 Vdc inductive 6-28 Vdc inductive 115 Vdc resistive 30° or 36° 1 amp 1 amp 0.25 amp 0.02 amp 0.10 amp 0.10 amp Angle of Throw 45° or 60° 90° 5 amps 5 amps 1 amp 2 amps 2 amps 2 amps — — — — — — To carry 10 amps continuously. Contact Resistance: 50 milliohms maximum Insulation Resistance: 1,000 megaohms minimum Voltage Breakdown: 1,000 Vac initially (500 Vac or better after most environmental tests) Life Expectancy: 100,000 mechanical cycles of operation. Note: Actual life is determined by a number of factors, including electrical loading, rate of rotation and environment, as well as maximum voltage breakdown required at the end of life. UL Recognition– Styles UA, UD, UM, UP, US and USP Grayhill styles A and M and their variations (D, P, S and SP) of the Series 42, 43, 44 and 54 rotary switches have been tested by Underwriters Laboratories. The letter U in the style indicates proper marking as required by Underwriters Laboratories. These switches are recognized under file number E35289. The UL rating for the Series 42, 43, 44 and 54 is as follows: Electrical Parameters: style UA = 1.0 ampere at 125 Vac. Style UM = 1.0 ampere at 125 Vac and also .5 ampere at 125 Vac, inductive load, 0.75 to 0.8 power factor. Rating based on the following criteria: Overload: 50 operations at 150% rated AC load Endurance: 6000 operations at the rated load with 1000 Vac dielectric strength before and after test Temperature Rise: Not to exceed 30°C when carrying rated AC load after test. Note: all dimensional drawings for the standard style Series 42, 43, 44 and 54 also apply to these switches, with the exception that switches are marked per specifications. Electrical Ratings Military Style General Rating: This rating is based on standard Grayhill tests of the Military style switch done at ambient conditions. It is provided for comparison to the Standard Style switch. Charts shown for non-shorting contacts (break before make) 7 CURRENT (AMPS) Rated: To make and break the following loads: 6 5 VOLTAGE 115 VAC RESISTIVE 4 3 2 1 0 0 10 25 50 CyCLES x 1,000 1.7 CURRENT (AMPS) Standard Style 1.5 VOLTAGE 30 VDC RESISTIVE 1.2 1.0 .75 INDUCTIVE (2.8 HENRIES) .50 .20 0 0 10 25 50 CyCLES x 1,000 Grayhill, Inc. • 561 Hillgrove Avenue • LaGrange, Illinois Voltage and Load: As listed in the chart One cycle is 360° rotation and a return through all switch positions to the starting position. The data for the curves was measured at sea level, 25°C and 68% relative humidity. The Series 42, 43, 44 and 54, style M, H and HS switches are made to meet requirements of MIL-DTL-3786, style SR04. Diallyl phthalate molded parts and the design of internal switching elements provide exceptional performance. Curves shown are typical load-life curves for Series 42, 43, 44 and 54, style M, H and HS switches with 30° or 36° angles of throw. They show the numbers of cycles of rotational life expectancy for the types of loads shown. Thus, with a 5 amp, 115 Vac resistive load, 10,000 cycles of life is expected. If the load is reduced to 3 amps, life is increased to 25,000 cycles.The larger angles of throw (45°, 60° or 90°) switch larger currents for a like number of cycles. Life limiting or failure criteria for these curves are: C o n t a c t R e s i s t a n c e : 5 0 milliohms maximum Insulation Resistance: 1,000 megaohms minimum between mutually insulated parts Voltage Breakdown: 1,000 Vac minimum between mutually insulated parts. These switches will carry 10 amps with maximum contact temperature rise of 20°C. Life can be predicted by Grayhill if less critical life characteristics, elevated temperature or reduced pressure is involved. MIL-S-3786 Electrical Values Military Style 60525-5997 • USA • Phone: 708-354-1040 • Fax: 708-354-2820 • www.grayhill.com Multi-Deck Rotary Switches specifications: Style M switches, at 85°C, approximately 68% humidity and sea level pressure and style H and HS at 125°C have been tested to make and break the following loads as stated in MIL-DTL-3786/SR04; 250 milliamperes at 28 Vdc resistive, 100 milliamperes at 28 Vdc inductive (2.8 henries); 75 milliamperes at 115 Vac resistive. These switches have also been tested at reduced barometric pressure (70,000 feet), 25°C at approximately 68% relative humidity to make and break the following loads as stated in MIL-DTL-3786/SR04; 200 milliamperes, 28 Vdc resistive; 25 milliamperes, 28 Vdc inductive (2.8 henries); 20 milliamperes, 115 Vac resistive. When tested to these loads and conditions the style M, H and HS switches meet the following life limiting or failure criteria after 25,000 cycles in accordance with MILS-3786. Contact Resistance: 50 milliohms maximum Insulation Resistance: 1,000 megaohms minimum between terminals and shafts Dielectric Strength: 1,000 Vac (atmospheric pressure) and 450 Vac (reduced pressure) minimum between mutually insulated parts. Bases: Melamine per (MIL-M-14) ASTM-D5948 Cover, Deck Separators, End Plate and Rotor Mounting Plate: Phenolic per (MIL-M-14) ASTM-D-5948 Mounting Bushings: Brass, tin/zinc-plated. Shaft, Cover Plate, Retaining Rings,Through Bolts, Shaft Extensions, Stop Arm, Thrust Washers Stop Washers and Rear Support Plate: Stainless Steel Detent Balls: Steel, nickel-plated Detent Springs: Tinned music wire Rotor Contact, Stator (Base) Contacts: Silver alloy Terminals (Except Common): Brass, tin plated Common Plate, Including Solder Lug: Brass, silver-plated .0003" minimum Mounting Hardware: Two mounting nuts .094" (2,39) thick by .562" (14,27) across flats and one internal tooth lockwasher are supplied with each switch. Stud Nuts, Mounting Nuts, Lock Washers: Tin/zinc-plated or stainless steel. Materials and Finishes Military Qualified Bases: Diallyl per (MIL-M-14) ASTM-D-5948 Cover, Deck Separators, End Plate and Rotor Mounting Plate: Diallyl per (MIL-M-14) ASTM-D-5948 These switches also meet MIL-DTL-3786/ SR04 for moisture resistance, medium and high shock, vibration (10 to 2000 cps), thermal shock (-65°C to 125°C), salt spray, explosion and terminal pull. Grayhill, Inc. • 561 Hillgrove Avenue • LaGrange, Illinois Mounting Bushings: Brass, tin/zinc-plated. Shaft, Cover Plate, Retaining Rings, Through Bolts, Shaft Extensions, Stop Arm, Stop Washers, Thrust Washers and Rear Support Plate: Stainless steel Detent Balls: Steel, nickel-plated Detent Springs: Tinned music wire Rotor Contact: Silver alloy Terminals, Common Plate including Solder Lug: Brass, silver-plated .0003" minimum Mounting Hardware: Two mounting nuts .094" thick by .562" across flats and one internal tooth lockwasher are supplied with each switch. Stud Nuts, Mounting Nuts, Lock Washers: Tin/zinc-plated or stainless steel. Additional Characteristics Standard Style and Military Qualified Contact: Shorting or non-shorting wiping contacts with over 150 grams of contact force Rotational Torque: 8-115 ounce-inches depending upon the number of poles per deck, number of decks and angle of throw Mechanical Life Expectancy: 100,000 cycles of operation Shaft Flat Orientation: Flat opposite contacting position of pole number one (See circuit diagram). Stop Strength: For Standard style: 15 poundinches minimum. For Adjustable stop styles: 12 pound-inches Extended Stud: Single shaft switches of six or more decks and concentric shaft switches of a combination of five or more decks (Standard style) or four or more decks (Military style) have longer studs with extra mounting nuts for recommended double end mount. 60525-5997 • USA • Phone: 708-354-1040 • Fax: 708-354-2820 • www.grayhill.com Rotary Switches When tested at sea level 25°C and 68% relative humidity with failure criteria of 50 milliohms max. and 750 Vac breakdown voltage, these switches will make and break the following loads: 250 mA at 28 Vdc, inductive (2.8 henries); 1.25 amps at 28 Vdc resistive; 2.0 amps at 115 Vac, 60 Hz resistive, for 10,000 cycles. Materials and Finishes Standard Style Multi-Deck Rotary Switches Choices and limitations: Series 42, 43, 44 and 54 A = Standard, Solder Lugs P = Standard, PC Mount Terminals D = Standard, Adjustable Stops H = Military Qualified, 125°C B = Military, Grounded Shaft G = Military, Low Level Rating S = Shaft and Panel Seal U = UL Recognized M = Military Qualified 85°C4 Single Shaft Switches Style Choices Angle of Series Unsealed Shaft/Panel Seal Throw Number of Decks 36° 42 Poles Per Deck Positions Per Pole1,3 Shorting or Non-Shorting 01 thru 12 01 thru 12 1 2 02 thru 103 02 thru 05 N or S N or S 30° 01 thru 12 01 thru 12 01 thru 08 01 thru 06 01 thru 04 01 thru 04 1 2 3 4 5 6 02 thru 123 02 thru 06 02 thru 04 02 or 03 02 02 N or S N or S N or S N or S N or S N or S 45° 01 thru 12 01 thru 06 01 thru 04 01 thru 03 1 2 3 4 02 thru 083 02 thru 04 02 02 N or S N or S N N 60° 01 thru 12 01 thru 06 01 thru 04 1 2 3 02 thru 063 02 or 03 02 N N N 90° 01 thru 12 01 thru 06 1 2 02 thru 043 02 N N 30° 01 thru 12 01 thru 12 01 thru 08 01 thru 06 1 2 3 4 AJ (2 thru 12)1 AJ (2 thru 6)1 AJ (2 thru 4)1 AJ (2 or 3)1 N or S N or S N or S N or S 36° 01 thru 12 01 thru 12 1 2 AJ (2 thru 10)1 AJ (2 thru 5)1 N or S N or S 36° 01 thru 12 1 02 thru 103 N or S A UA UM5 M MB MG MBG H HB HG HBG 44 S US — MS4 MBS4 MGS4 MBGS4 HS HBS HGS HBGS Rotary Switches 44 D UD — — 42 P UP 42 SP USP Concentric Shaft Switches Series Style Angle of Section A (Front) Section B (Rear) Choices Throw Decks Poles Position N or S Decks Poles Position N or S CONCENTRIC SHAFT, 2 SWITCHES 54 A2 UA2 M2 43 30° 01 thru 03 01 thru 03 1 2 36° 01 thru 03 1 30° 01 thru 03 01 thru 03 36° 30° 02 thru 123 02 thru 06 N or S N or S 01 thru 03 01 thru 03 01 or 02 01 01 01 1 2 3 4 5 6 02 thru 123 02 thru 06 02 thru 04 02 or 03 02 02 N or S N or S N or S N or S N or S N or S 02 thru 105 N or S 01 thru 03 01 thru 03 1 2 02 thru 103 02 thru 05 N or S N or S 1 2 AJ (2-12)1 AJ (2-6)1 N or S N or S 01 thru 03 1 AJ (2-10)1 N or S 01 thru 03 01 thru 03 1 2 02 thru 125 02 thru 06 N or S N or S ADD-A-POT SWITCHES 54 43 54 D UD M For Adjustable Stop (with the letter D), use AJ instead of number of positions when ordering. 2 For 45°, 60° or 90° throws in Series 54 switches of these styles, see Standard Options. 3 For single pole switches with the maximum positions per pole, continuous rotation is possible. Specify fixed stop or continuous rotation when ordering single shaft switches. Concentric shaft switches have continuous rotation. 1 Second shaft operates a potentiometer supplied by the customer. Rear mounting plates are provided. Styles which include both M and S are not qualified but are made of the same materials and construction as qualified types. For qualified switches with shaft and panel seal, use equivalent HS style. 5 UM switches are made of the same materials and construction as the M style switches. For military switch UM is not required; use M style. 4 Grayhill, Inc. • 561 Hillgrove Avenue • LaGrange, Illinois 60525-5997 • USA • Phone: 708-354-1040 • Fax: 708-354-2820 • www.grayhill.com Multi-Deck Rotary Switches Accessories Internal Tooth Lockwasher–Figure A For a 3/8" bushing. Approximately 0.500" (12,7) outside diameter, .022" (0,56) thickness. Material is cadmium-plated steel. Part No. 12Q1272-1 For a 1/4" bushing. Approximately 0.400" (10,16) outside diameter, .018" (0,46) thickness. Material is FIGuRE A steel, tin/zinc plated. Non-Turn Washer–Figure B Can be ordered as extra hardware for the Series 5000, 24, 42, 43, 44, 54, 71B, 53, 57 and 59 rotary switches. The internal key of the washer slides into the bushing keyway. The right angle tab locks into a predrilled hole on the back side of the mounting panel. Material is brass, tin/zinc plated. Part No. 12C1087-1 bushing to the panel. The kit consists of four items: a grooved hex nut, a keyed washer, a keyed seal and a non-turn washer. Assembly is described on Page J-53. Dimensions of panel seal kit items are shown in Figure C. This kit seals the bushing to the panel; it does not seal the shaft to the bushing. Not usable with adjustable stop switches. Part No. 42-24 .625 ± .010 (15,88 ± 0,25) DIA. .375 + .004 – .000 (9,53 + 0,10) DIA. .375 ± .005 (9,53 ± 0,13) CL Panel Seal Kit–Figure C .125 ± .003 (3,18 ± 0,08) Non-turn Washer Sold as a separate item to seal the switch .060 ± .002 (1,52 ± 0,05) .154 + .004 –.000 (3,91 + 0,10 –0,00) DIA. .625 ± .010 (15,88 ± 0,25) DIA. .376 + .003 –.000 (9,55 + 0,08 –0,00) DIA. .437 ± .010 (11,10 ± 0,25) .032 ± .002 (0,81 ± 0,05) .125 ± .010 (3,18 ± 0,25) .120 ± .003 (3,18 ± 0,08) FIGuRE B .032 ± .002 (0,81 ± 0,05) .045 ± .003 (1,14 ± 0,08) .562 (14,27) ACROSS FLATS .010 ± .002 (0,25 ± 0,05) .187 ± .010 (4,75 ± 0,25) .088 (2,24)/ .093 (2,36) Seal FIGuRE C Keyed Washer Hex Nut ORDERING INFORMATION: Single Shaft Switches, Add-A-Pot Switches 44M30–02–1–12N–F Stop Arrangement: Add letter F to a one pole per deck switch with the maximum number of positions for a stop between position 1 and the last position. Leave blank for continuous rotation Type of Contacts: N = Non-shorting; S = Shorting Positions Per Pole: Requires 02 positions as a minimum to maximum allowable dependent on the angle of throw and poles per deck. Use AJ for adjustable stops (Styles D and UD). Poles Per Deck: As limited by angle of throw, switch series and style * All rotary switches that are required to have military designated markings and testing adhering to MIL-3786 are to be ordered by specifying the military part number identified on the appropriate slash sheet. ORDERING INFORMATION: Concentric Shaft Rotary Switches Series: Determined by the angle of throw, applicable to both sections Style*: Letter(s) from the Choices and Limitations chart Section A (front) Number of Decks: As limited by the number of poles per deck Poles Per Deck: As limited by the angle of throw Positions Per Pole: Requires 02 positions as a minimum to the maximum allowable dependent on the angle of throw and the poles per deck Type of Contacts: N=Non-shorting, S=Shorting. All one pole per deck switches with the maximum number of positions are continuous rotation 43M02110N–M03203S Section B (rear) The limitations listed for Section A apply to Section B Type of Contacts Positions Per Pole Poles Per Deck Number of Decks Style * All rotary switches that are required to have military designated markings and testing adhering to MIL-3786 are to be ordered by specifying the military part number identified on the appropriate slash sheet. Available from your local Grayhill Distributor For prices and discounts, contact a local Sales Office, an authorized local Distributor or Grayhill. Grayhill, Inc. • 561 Hillgrove Avenue • LaGrange, Illinois 60525-5997 • USA • Phone: 708-354-1040 • Fax: 708-354-2820 • www.grayhill.com Rotary Switches Series: Determined by the type of switch and the angle of throw Style*: Letter(s) from the Choices and Limitations chart Angle of Throw: Must agree with Series Number Number of Decks: As limited by the angle of throw, the poles per deck, switch style and type of contacts
44H30-04-1-06N
物料型号:Grayhill品牌的多面板旋转开关,包括42、43、44和54系列。

器件简介:这些开关具有坚固的构造,确保设备在其使用寿命期间都能正常操作。它们有多种电路选项,并且有军用规格的版本,符合MIL-S-3786/04标准。

引脚分配:文档提供了详细的尺寸和引脚分配图,包括不同系列开关的直径、孔径、以及固定螺钉的尺寸等。

参数特性: - 电气额定值:包括在不同角度的投掷下,对于不同类型负载(如电阻性、感性)的电流和电压的额定值。 - 接触电阻:最大50毫欧姆。 - 绝缘电阻:最小1000兆欧姆。 - 电压击穿:最初1000 VAC(经过大多数环境测试后为500 VAC或更好)。 - 机械寿命:100,000次机械操作周期。

功能详解:开关具有多种功能选项,例如轴/面板密封、可调节的停止位、PC终止等。

应用信息:适用于需要高电流板级应用的场合,例如军事设备原型。但是,提交政府批准时,应使用固定停止位的合格样式。

封装信息:提供了详细的安装尺寸和安装板图案,以及PC安装端子的尺寸。

此外,文档还包含了军用规格开关的额外特性,如轴和面板密封、电气值、材料和表面处理等。还有关于如何订购开关的信息,包括系列、样式、投掷角度、停靠安排、接触类型、每极位置数、每层极数等。
44H30-04-1-06N 价格&库存

很抱歉,暂时无法提供与“44H30-04-1-06N”相匹配的价格&库存,您可以联系我们找货

免费人工找货