0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
C13064-P

C13064-P

  • 厂商:

    NICOMATIC

  • 封装:

  • 描述:

    CMM CONTACT-FEMALE CRIMP

  • 数据手册
  • 价格&库存
C13064-P 数据手册
C R E AT I V E INTERCONNECT SOLUTIONS CMM MIL55302 SPECIFICATIONS MODULAR CONNECTOR SUB-D TYPE _ HARSH ENVIRONMENT 2mm pitch Couv_rabat_2011.qxd:Mise en page 1 18/05/11 11:37 Page1 SUBSIDIARIES FRANCE T:+33 (0)4 50 36 13 85 france@nicomatic.com UNITED STATES T:+1 21 54 44 95 80 usa@nicomatic.com SOUTH KOREA T: +82 (0)2 553 6822 korea@nicomatic.com CHINA T:+86 (0)22 23 85 88 36 china@nicomatic.com JAPAN T: +81 (0)80 2138 0909 japan@nicomatic.com INDIA T: +91 80 421 315 74 india@nicomatic.com SINGAPORE T: +65 62 62 12 80 singapore@nicomatic.com UNITED KINGDOM T: +44 (0) 11 83 80 10 33 uk@nicomatic.com CANADA T: +41 (0) 438 885 3395 canada@nicomatic.com GERMANY T: +49 (0)33 203 878 801 germany@nicomatic.com TAIWAN T: +886 (0)2 2311 2667 taiwan@nicomatic.com MEMBER OF Gifas - Eden Aerospace cluster TURKEY T: +90 (0) 312 504 37 29 turkey@nicomatic.com WEBSITE nicomatic.com CAREER COME & JOIN US ◆ Improving technology ◆ Diversity & gender equality ◆ We promote initiative & responsibility CMM Series Micro-connectors CMM CATALOG HEADQUARTER NICOMATIC specializes in the design, development and manufacture of electronic connectors. The CMM MICRO CONNECTOR interconnection system is a 2mm pitch connector (square matrix) with proven high reliability under the most extreme environmental conditions: - Flexible architecture: "Board to Board", "Board toWire" and "Wire toWire" configurations - Modular and hybrid design: mixed layout full option with Low Frequency – LF (over 5 Amp) – and High Frequency – HF - (over 11 GHz) and High Power - HP - (over 30 Amp) - High reliability contact design & High performance under harsh use conditions - Secure: integral jacking mechanism or locking by spring latch The CMM MICRO CONNECTOR is a complete and standard range of connectors: - CMM 100 series: 1 row – from 2 to 25 LF contacts - CMM 200 series: 2 rows – from 4 to 50 LF contacts - CMM 220 series: 2 rows – from 4 to 60 LF contacts, or up to 15 HF or HP contacts (series 30) - CMM 320 series: 3 rows – from 6 to 120 LF contacts, or up to 20 HF or HP contacts (series 30) - CMM 340 series: 3 rows – min. 6 LF contacts and up to 64 HF or HP contacts (series 22) Direct benefits: - Space saving: - 40% in surface and over - 60% in volume - Weight saving: - 20 to - 50% vs. usual solution for same functionalities - Reduce number of connectors: 2 or 3 connectors in 1 thanks to a modular concept - Cost effective solution: custom connector assembly from standard components - Proven success stories in on-board electronic systems - Full traceability with EN9100:2003 - Short lead time: 1 week express service, Premium service, Fast sampling and prototyping - Online services (www.nicomatic.com): Free use of My Niomatic service (2D & 3D drawings), automatic part number & mating-half configurators, technical support . READY TO JOIN OUR TEAM? recruitment@nicomatic.com C R E AT I V E I N T E R CO N N E CT S O LU T I O N S CMM MIL55302 SPECIFICATIONS MODULAR CONNECTOR _ HARSH ENVIRONMENT The CMM has been developed for the aerospace, avionics, instrumentation & control, defence and transportation markets, with applications that include IFES, HUDs, flight controls, FADEC units, radars, missiles, electro-optical sighting systems, satellites, mobile radios, power supplies, UAVs and engine controls. It is also used in a growing number of medical, and telecom applications. 2mm pitch 2 Couv_rabat_2011.qxd:Mise en page 1 18/05/11 11:37 Page2 Dimension Tables CMM 100/200 SERIES CMM Specifications (with LF contacts) Manufacturer and designer of innovative interconnect solutions MATERIALS in male & female styles for LF contacts INSULATOR: Special PPS (Polyphenylene Sulfide Fiberglass filled thermoplastic) UL 94-V0 CMM SERIES 100 & 200 Male LF contacts number series 100 2 3 4 LF contacts number series 200 4 6 8 Length in mm A 2 4 6 Length in mm (Strap) B 6,7 8,7 10,7 Length in mm C 7,4 9,4 11,4 Length C with Latches fitted 7,8 9,8 11,8 5 10 8 12,7 13,4 13,8 6 12 10 14,7 15,4 15,8 7 14 12 16,7 17,4 17,8 8 16 14 18,7 19,4 19,8 9 18 16 20,7 21,4 21,8 10 20 18 22,7 23,4 23,8 11 22 20 24,7 25,4 25,8 12 24 22 26,7 27,4 27,8 13 26 24 28,7 29,4 29,8 14 28 26 30,7 31,4 31,8 15 30 28 32,7 33,4 33,8 16 32 30 34,7 35,4 35,8 17 34 32 36,7 37,4 37,8 18 36 34 38,7 39,4 39,8 19 38 36 40,7 41,4 41,8 20 40 38 42,7 43,4 43,8 21 42 40 44,7 45,4 45,8 22 44 42 46,7 47,4 47,8 23 46 44 48,7 49,4 49,8 24 48 46 50,7 51,4 51,8 25 50 48 52,7 53,4 53,8 • Radiation resistance • No humidity absorption • Oxygen free Note : PPS characteristics are recognized for space applications CMM SERIES 100 & 200 Female LF contacts number series 100 LF contacts number series 200 Length in mm A Length in mm B D E F G LF CONTACTS REFERENCE MARK NUMBER FOR CMM SERIES 200 Male & Female CMM 220 SERIES LF contacts number Distance between A axis B CMM SERIES 220 Length in mm Male & LF contacts Female reference mark number C D E F G 2 4 2 7 3 6 4 9 4 8 6 11 5 10 8 13 6 12 10 15 7 14 12 17 8 16 14 19 9 18 16 21 10 20 18 23 11 22 20 25 12 24 22 27 13 26 24 29 14 28 26 31 15 30 28 33 16 32 30 35 17 34 32 37 18 36 34 39 19 38 36 41 20 40 38 43 21 42 40 45 22 44 42 47 23 46 44 49 24 48 46 51 25 50 48 53 1 2 3 4 1 3 4 6 1 4 5 8 1 5 6 10 1 6 7 12 1 7 8 14 1 8 9 16 1 9 10 18 1 10 11 20 1 11 12 22 1 12 13 24 1 13 14 26 1 14 15 28 1 15 16 30 1 16 17 32 1 17 18 34 1 18 19 36 1 19 20 38 1 20 21 40 1 21 22 42 1 22 23 44 1 23 24 46 1 24 25 48 1 25 26 50 Special contacts number CMM 220 Male & Female Distance between A axis Special B contacts only Length in mm C LF contacts number 6 Distance between A 2 axis B 11 Length in mm C 17 CMM D 1 SERIES 320 E 2 Male & LF contacts F 3 Female reference mark G 4 number H 5 J 6 9 4 13 19 1 3 4 6 7 9 12 10 17 22 1 6 7 12 12 6 15 21 1 4 5 8 9 12 14 12 19 24 1 7 8 14 16 14 21 26 1 8 9 16 18 16 23 28 1 9 10 18 20 18 25 30 1 10 11 20 22 20 27 32 1 11 12 22 24 22 29 34 1 12 13 24 26 24 31 36 1 13 14 26 28 26 33 38 1 14 15 28 30 28 35 40 1 15 16 30 32 30 37 42 1 16 17 32 34 32 39 44 1 17 18 34 36 34 41 46 1 18 19 36 38 36 43 48 1 19 20 38 40 38 45 50 1 20 21 40 42 40 47 52 1 21 22 42 44 42 49 54 1 22 23 44 46 44 51 56 1 23 24 46 48 46 53 58 1 24 25 48 3 8 17 22 4 12 21 26 5 16 25 30 6 20 29 34 7 24 33 38 8 28 37 42 9 32 41 46 10 36 45 50 11 40 49 54 18 10 19 25 1 6 7 12 13 18 21 12 21 27 1 7 8 14 15 21 24 14 23 29 1 8 9 16 17 24 27 16 25 31 1 9 10 18 19 27 30 18 27 33 1 10 11 20 21 30 33 20 29 35 1 11 12 22 23 33 36 22 31 37 1 12 13 24 25 36 39 24 33 39 1 13 14 26 27 39 42 26 35 41 1 14 15 28 29 42 45 28 37 43 1 15 16 30 31 45 48 30 39 45 1 16 17 32 33 48 51 32 41 47 1 17 18 34 35 51 54 34 43 49 1 18 19 36 37 54 57 36 45 51 1 19 20 38 39 57 60 38 47 53 1 20 21 40 41 60 63 40 49 55 1 21 22 42 43 63 66 42 51 57 1 22 23 44 45 66 69 44 53 59 1 23 24 46 47 69 72 46 55 61 1 24 25 48 49 72 75 48 57 63 1 25 26 50 51 75 78 50 59 65 1 26 27 52 53 78 81 52 61 67 1 27 28 54 55 81 84 54 63 69 1 28 29 56 57 84 87 56 65 71 1 29 30 58 59 87 50 48 55 60 1 25 26 50 12 44 53 58 90 58 67 73 1 30 31 60 61 90 93 60 69 75 1 31 32 62 63 93 52 50 57 62 1 26 27 52 54 52 59 64 1 27 28 54 13 48 57 62 96 62 71 77 1 32 33 64 65 96 Female: Body : copper alloy / Ni + Au 0,2 µ Socket : beryllium copper / Ni + Au > 1,25µ 56 54 61 66 1 28 29 56 58 56 63 68 1 29 30 58 60 58 65 70 1 30 31 60 14 52 61 66 99 64 73 79 1 33 34 66 67 99 102 66 75 81 1 34 35 68 69 102 105 68 77 83 1 35 36 70 71 105 108 70 79 85 1 36 37 72 73 108 111 72 81 87 1 37 38 74 75 111 114 74 83 89 1 38 39 76 77 114 117 76 85 91 1 39 40 78 79 117 OMM SERIES MICRO-CIRCULAR CONNECTORS High density of contacts in smallest circular connector shape Space saving feature Security of connection Light weight Lockable captive fixing hardware ELECTRICAL • All contacts 3 A max. @ 25°C 2.2 A max. @ 85°C • Working voltage (sea level) Tested at 800 V DC • Proof voltage Tested at 1 200 V DC • Contact resistance (initially) max. 10 mΩ • Insulation resistance 1 000 MΩ min. MECHANICAL 15 56 65 70 • Mechanical operations Up to 2500 cycles • Contact insertion and withdrawal force 2 N max. / 0.2 N min. per contact • Contact retention in insulator 10 N min. • Contact replacement in insulator 1-3 cycles (Crimp contacts only) ENVIRONMENTAL 120 78 87 93 1 40 41 80 81 120 • Temperature cycling From - 60°C to + 260°C Reflow solder process compatible (+260°C) • Vibration severity 0.75 mm, 10 g RMS 6 hours long random with superimposed sinusoid. No intermittencies measured when using an H.S.L.I (High Speed Logic Interrupt) detector with a trip threshold of 2 ns. MIL-DTL-55302F Test Condition III [147.1 m/s2 (15 gn) peak] • Shock severity 100 g for 6 ms • Solvent resistance CMM 340 SERIES CMM 340 Male & Female Special contacts only 3 2mm pitch high density robust metal shielded micro connector Self cabling connector Simple and easy to design-in New alternative under MIL-DTL-83513G or MIL-DTL-55302F test routine Very flexible custom design (fixing hardware, contacts…) Female: Body : copper alloy / Ni + Au > 0,2 µ Socket : beryllium copper / Ni + Au > 1,25µ • Latch : Beryllium copper/plated nickel (CMM 100/200 series only) in male & female styles for LF contacts 15 8 17 23 1 5 6 10 11 15 MICRO-D MIX™ DMM SERIES MICRO-CONNECTORS FIXING HARDWARE: • Jackscrew: Stainless steel. in male & female styles for HF/HP contacts 2 4 13 18 CMM 320 SERIES CRIMP LF CONTACTS : Male: Body : copper alloy / Ni + Au > 1µ in male & female styles for LF contacts 4 6 8 10 2 4 6 8 9 11 13 15 14 16 18 20 1 1 1 1 2 3 4 5 3 4 5 6 4 6 8 10 CMM 220 SERIES P.C. LF CONTACTS : Male: Tail : copper alloy / Ni + Au flash 0,1µ Contact area : copper alloy / Ni + Au > 1µ MICROFLEX HARNESS SOLUTION Low weight: save up to -30% vs. bulky cable Smaller space-factor 2 in 1 technology with CMM & CRIMPFLEX Avionic & aerospace MIL comply High quality of crimp (gaz tie) High productivity: 2 to 30 contacts in 1 crimp 4D-FLOATING CONNECTORS 4D tolerance absorption: 4D = 3 axial movements + 1 rotation High efficiency “Bone design” (round shape and 4 spring-lips contact) Complies with MIL-DTL-55302F Auto alignment feature Adaptable to customer requests CUSTOM PRODUCTS You can rely on our R&D department know-how and long experience. Our permanent innovation was recognized and labelized as "highly Innovative" by the European Union Our in-house production and assembly capacity offers you the possibility to create customized products : stamping and moulding, micro-screw machining, laser cut, CNC, specific machinery development, clean room, measure and test lab. Fully integrated industrial company, Nicomatic can reduce your risks, can secure your development and achieve the solution that will make the difference on the market. in male & female styles for HF/HP contacts Special contacts number 4 6 8 Distance between A 2,5 5 7,5 axis B 12,5 15 17,5 Length in mm C 18,5 21 23,5 10 10 20 26 12 12,5 22,5 28,5 14 15 25 31 16 17,5 27,5 33,5 18 20 30 36 20 22,5 32,5 38,5 22 25 35 41 24 27,5 37,5 43,5 26 30 40 46 28 32,5 42,5 48,5 30 35 45 51 32 37,5 47,5 53,5 34 40 50 56 36 42,5 52,5 58,5 38 45 55 61 40 47,5 57,5 63,5 42 50 60 66 44 52,5 62,5 68,5 46 55 65 71 48 57,5 67,5 73,5 50 60 70 76 52 62,5 72,5 78,5 54 65 75 81 56 67,5 77,5 83,5 58 70 80 86 60 72,5 82,5 88,5 62 75 85 91 Note : The CMM micro-connectors are designed to meet or exceed the relevant electrical and environmental performances described in MIL-DTL-55302F & BS-9525-F0033 standards. 64 77,5 87,5 93,5 4 Date of issue : May 2011 Catalogue reference : C.CMM.1000/GB NICOMATIC maintains a policy of ongoing development and improvement. It therefore reserves the right to change design, dimensions and specifications without notice. All information stated inside this catalogue is not contractual and subject to change (eg. standard connector configurations). Copyright 2011 by NICOMATIC (All Rights Reserved). 125 Couv_rabat_2011.qxd:Mise en page 1 18/05/11 11:37 Page2 Dimension Tables CMM 100/200 SERIES CMM Specifications (with LF contacts) Manufacturer and designer of innovative interconnect solutions MATERIALS in male & female styles for LF contacts INSULATOR: Special PPS (Polyphenylene Sulfide Fiberglass filled thermoplastic) UL 94-V0 CMM SERIES 100 & 200 Male LF contacts number series 100 2 3 4 LF contacts number series 200 4 6 8 Length in mm A 2 4 6 Length in mm (Strap) B 6,7 8,7 10,7 Length in mm C 7,4 9,4 11,4 Length C with Latches fitted 7,8 9,8 11,8 5 10 8 12,7 13,4 13,8 6 12 10 14,7 15,4 15,8 7 14 12 16,7 17,4 17,8 8 16 14 18,7 19,4 19,8 9 18 16 20,7 21,4 21,8 10 20 18 22,7 23,4 23,8 11 22 20 24,7 25,4 25,8 12 24 22 26,7 27,4 27,8 13 26 24 28,7 29,4 29,8 14 28 26 30,7 31,4 31,8 15 30 28 32,7 33,4 33,8 16 32 30 34,7 35,4 35,8 17 34 32 36,7 37,4 37,8 18 36 34 38,7 39,4 39,8 19 38 36 40,7 41,4 41,8 20 40 38 42,7 43,4 43,8 21 42 40 44,7 45,4 45,8 22 44 42 46,7 47,4 47,8 23 46 44 48,7 49,4 49,8 24 48 46 50,7 51,4 51,8 25 50 48 52,7 53,4 53,8 • Radiation resistance • No humidity absorption • Oxygen free Note : PPS characteristics are recognized for space applications CMM SERIES 100 & 200 Female LF contacts number series 100 LF contacts number series 200 Length in mm A Length in mm B D E F G LF CONTACTS REFERENCE MARK NUMBER FOR CMM SERIES 200 Male & Female CMM 220 SERIES LF contacts number Distance between A axis B CMM SERIES 220 Length in mm Male & LF contacts Female reference mark number C D E F G 2 4 2 7 3 6 4 9 4 8 6 11 5 10 8 13 6 12 10 15 7 14 12 17 8 16 14 19 9 18 16 21 10 20 18 23 11 22 20 25 12 24 22 27 13 26 24 29 14 28 26 31 15 30 28 33 16 32 30 35 17 34 32 37 18 36 34 39 19 38 36 41 20 40 38 43 21 42 40 45 22 44 42 47 23 46 44 49 24 48 46 51 25 50 48 53 1 2 3 4 1 3 4 6 1 4 5 8 1 5 6 10 1 6 7 12 1 7 8 14 1 8 9 16 1 9 10 18 1 10 11 20 1 11 12 22 1 12 13 24 1 13 14 26 1 14 15 28 1 15 16 30 1 16 17 32 1 17 18 34 1 18 19 36 1 19 20 38 1 20 21 40 1 21 22 42 1 22 23 44 1 23 24 46 1 24 25 48 1 25 26 50 Special contacts number CMM 220 Male & Female Distance between A axis Special B contacts only Length in mm C LF contacts number 6 Distance between A 2 axis B 11 Length in mm C 17 CMM D 1 SERIES 320 E 2 Male & LF contacts F 3 Female reference mark G 4 number H 5 J 6 9 4 13 19 1 3 4 6 7 9 12 10 17 22 1 6 7 12 12 6 15 21 1 4 5 8 9 12 14 12 19 24 1 7 8 14 16 14 21 26 1 8 9 16 18 16 23 28 1 9 10 18 20 18 25 30 1 10 11 20 22 20 27 32 1 11 12 22 24 22 29 34 1 12 13 24 26 24 31 36 1 13 14 26 28 26 33 38 1 14 15 28 30 28 35 40 1 15 16 30 32 30 37 42 1 16 17 32 34 32 39 44 1 17 18 34 36 34 41 46 1 18 19 36 38 36 43 48 1 19 20 38 40 38 45 50 1 20 21 40 42 40 47 52 1 21 22 42 44 42 49 54 1 22 23 44 46 44 51 56 1 23 24 46 48 46 53 58 1 24 25 48 3 8 17 22 4 12 21 26 5 16 25 30 6 20 29 34 7 24 33 38 8 28 37 42 9 32 41 46 10 36 45 50 11 40 49 54 18 10 19 25 1 6 7 12 13 18 21 12 21 27 1 7 8 14 15 21 24 14 23 29 1 8 9 16 17 24 27 16 25 31 1 9 10 18 19 27 30 18 27 33 1 10 11 20 21 30 33 20 29 35 1 11 12 22 23 33 36 22 31 37 1 12 13 24 25 36 39 24 33 39 1 13 14 26 27 39 42 26 35 41 1 14 15 28 29 42 45 28 37 43 1 15 16 30 31 45 48 30 39 45 1 16 17 32 33 48 51 32 41 47 1 17 18 34 35 51 54 34 43 49 1 18 19 36 37 54 57 36 45 51 1 19 20 38 39 57 60 38 47 53 1 20 21 40 41 60 63 40 49 55 1 21 22 42 43 63 66 42 51 57 1 22 23 44 45 66 69 44 53 59 1 23 24 46 47 69 72 46 55 61 1 24 25 48 49 72 75 48 57 63 1 25 26 50 51 75 78 50 59 65 1 26 27 52 53 78 81 52 61 67 1 27 28 54 55 81 84 54 63 69 1 28 29 56 57 84 87 56 65 71 1 29 30 58 59 87 50 48 55 60 1 25 26 50 12 44 53 58 90 58 67 73 1 30 31 60 61 90 93 60 69 75 1 31 32 62 63 93 52 50 57 62 1 26 27 52 54 52 59 64 1 27 28 54 13 48 57 62 96 62 71 77 1 32 33 64 65 96 Female: Body : copper alloy / Ni + Au 0,2 µ Socket : beryllium copper / Ni + Au > 1,25µ 56 54 61 66 1 28 29 56 58 56 63 68 1 29 30 58 60 58 65 70 1 30 31 60 14 52 61 66 99 64 73 79 1 33 34 66 67 99 102 66 75 81 1 34 35 68 69 102 105 68 77 83 1 35 36 70 71 105 108 70 79 85 1 36 37 72 73 108 111 72 81 87 1 37 38 74 75 111 114 74 83 89 1 38 39 76 77 114 117 76 85 91 1 39 40 78 79 117 OMM SERIES MICRO-CIRCULAR CONNECTORS High density of contacts in smallest circular connector shape Space saving feature Security of connection Light weight Lockable captive fixing hardware ELECTRICAL • All contacts 3 A max. @ 25°C 2.2 A max. @ 85°C • Working voltage (sea level) Tested at 800 V DC • Proof voltage Tested at 1 200 V DC • Contact resistance (initially) max. 10 mΩ • Insulation resistance 1 000 MΩ min. MECHANICAL 15 56 65 70 • Mechanical operations Up to 2500 cycles • Contact insertion and withdrawal force 2 N max. / 0.2 N min. per contact • Contact retention in insulator 10 N min. • Contact replacement in insulator 1-3 cycles (Crimp contacts only) ENVIRONMENTAL 120 78 87 93 1 40 41 80 81 120 • Temperature cycling From - 60°C to + 260°C Reflow solder process compatible (+260°C) • Vibration severity 0.75 mm, 10 g RMS 6 hours long random with superimposed sinusoid. No intermittencies measured when using an H.S.L.I (High Speed Logic Interrupt) detector with a trip threshold of 2 ns. MIL-DTL-55302F Test Condition III [147.1 m/s2 (15 gn) peak] • Shock severity 100 g for 6 ms • Solvent resistance CMM 340 SERIES CMM 340 Male & Female Special contacts only 3 2mm pitch high density robust metal shielded micro connector Self cabling connector Simple and easy to design-in New alternative under MIL-DTL-83513G or MIL-DTL-55302F test routine Very flexible custom design (fixing hardware, contacts…) Female: Body : copper alloy / Ni + Au > 0,2 µ Socket : beryllium copper / Ni + Au > 1,25µ • Latch : Beryllium copper/plated nickel (CMM 100/200 series only) in male & female styles for LF contacts 15 8 17 23 1 5 6 10 11 15 MICRO-D MIX™ DMM SERIES MICRO-CONNECTORS FIXING HARDWARE: • Jackscrew: Stainless steel. in male & female styles for HF/HP contacts 2 4 13 18 CMM 320 SERIES CRIMP LF CONTACTS : Male: Body : copper alloy / Ni + Au > 1µ in male & female styles for LF contacts 4 6 8 10 2 4 6 8 9 11 13 15 14 16 18 20 1 1 1 1 2 3 4 5 3 4 5 6 4 6 8 10 CMM 220 SERIES P.C. LF CONTACTS : Male: Tail : copper alloy / Ni + Au flash 0,1µ Contact area : copper alloy / Ni + Au > 1µ MICROFLEX HARNESS SOLUTION Low weight: save up to -30% vs. bulky cable Smaller space-factor 2 in 1 technology with CMM & CRIMPFLEX Avionic & aerospace MIL comply High quality of crimp (gaz tie) High productivity: 2 to 30 contacts in 1 crimp 4D-FLOATING CONNECTORS 4D tolerance absorption: 4D = 3 axial movements + 1 rotation High efficiency “Bone design” (round shape and 4 spring-lips contact) Complies with MIL-DTL-55302F Auto alignment feature Adaptable to customer requests CUSTOM PRODUCTS You can rely on our R&D department know-how and long experience. Our permanent innovation was recognized and labelized as "highly Innovative" by the European Union Our in-house production and assembly capacity offers you the possibility to create customized products : stamping and moulding, micro-screw machining, laser cut, CNC, specific machinery development, clean room, measure and test lab. Fully integrated industrial company, Nicomatic can reduce your risks, can secure your development and achieve the solution that will make the difference on the market. in male & female styles for HF/HP contacts Special contacts number 4 6 8 Distance between A 2,5 5 7,5 axis B 12,5 15 17,5 Length in mm C 18,5 21 23,5 10 10 20 26 12 12,5 22,5 28,5 14 15 25 31 16 17,5 27,5 33,5 18 20 30 36 20 22,5 32,5 38,5 22 25 35 41 24 27,5 37,5 43,5 26 30 40 46 28 32,5 42,5 48,5 30 35 45 51 32 37,5 47,5 53,5 34 40 50 56 36 42,5 52,5 58,5 38 45 55 61 40 47,5 57,5 63,5 42 50 60 66 44 52,5 62,5 68,5 46 55 65 71 48 57,5 67,5 73,5 50 60 70 76 52 62,5 72,5 78,5 54 65 75 81 56 67,5 77,5 83,5 58 70 80 86 60 72,5 82,5 88,5 62 75 85 91 Note : The CMM micro-connectors are designed to meet or exceed the relevant electrical and environmental performances described in MIL-DTL-55302F & BS-9525-F0033 standards. 64 77,5 87,5 93,5 4 Date of issue : May 2011 Catalogue reference : C.CMM.1000/GB NICOMATIC maintains a policy of ongoing development and improvement. It therefore reserves the right to change design, dimensions and specifications without notice. All information stated inside this catalogue is not contractual and subject to change (eg. standard connector configurations). Copyright 2011 by NICOMATIC (All Rights Reserved). 125 Catalogue_2011_jauneetnoir.qxd:Miseenpage117/05/1116:34Page5 HF / HP contacts specifications MATERIALS • Spring loaded parts Be/Cu gold plated • Other metal parts Copper alloy • Insulator PTFE (HF) • Retaining clip Be/Cu Ni plated MECHANICAL • Mechanical operations Up to 500 cycles • Insertion force From 0.60 to 5 N per contact • Withdrawal force From 0.50 to 2 N per contact • Secure overlapping 1.30 mm • Contact replacement in insulator 50 cycles for HF / HP 30 series (5 cycles for HF / HP 22 series) ELECTRICAL High Power (HP) Contact Intensity per contact Intensity per connector Dielectric Voltage (seal level) Withstanding voltage Rated voltage High Altitude 70000ft : Withstanding voltage Rated voltage Contact resistance max. 3 mΩ Series 30 Series 22 35A 20A High Frequency (HF) Contact Impedance 5 0 Ω / 75Ω Insulation resistance 106 M Ω 20A 10A Insulation between 2 contacts -75 dB (depending on cable) 1500VRMS 500 VRMS 900VRMS 300 VRMS 360 VRMS 120 VRMS 300 VRMS 100 VRMS Withstanding voltage (sea level) 1000 VRMS Rated voltage 80 v AC / 500 mA Contacts HF on cable Frequency range up to Series 30 20 GHz Serie 22 6 GHz ENVIRONMENTAL • Temperature cycling From -60°C to +260°C • Salt spray test 96 hrs * • Humidity test 56 days @ 90% humidity HF / HP CONTACTS PART NUMBERING “30” = series 30 [ø 3mm] (CMM 220 / 320) “22” = series 22 [ø 2.2mm] (CMM 340) These two digits are linked to the connector Do not use them inside a CMM part number (when loaded) Contact type : 3 = Straight 4 = Right Angle 5 = SMT Right Angle 6 = SMT straight - Termination length (only for PCB contacts) “CMM” = standard 3 mm “45” = 4,5 mm “…” - Special contacts : 1 = male HF 2 = female HF 3 = male HP 4 = female HP Contact termination : “00” = PCB, “xx” = cable diameter x 10 “…” Important notice: According to the routines test other than MIL our technical features for CMM Micro-connectors reach a higher result. For more information, please feel in the contact form on the website. For example: - Mechanical operations: up to 5 000 cycles - High temperature test: 1 000H at 250°C - Application with LVDS signal @ 400 MHz, impedance 100 Ohm - High speed: USB, 1Gb/s Ethernet… * without fixings 5 LF : low frequency contacts Female Male PRESENTATION Straight PCB Type Y 90° PCB Type V Straight SMT Type T 90° SMT Type R Crimp Type S - C Straight PCB Type PF Press fit INFORMATION TABLE CMM RANGE Male 100/200 Female Male 220 Female Male 320 Female Male 340 Female Y YL L=3,0 L=4,5 Y YL L=3,0 L=4,5 STRAIGHT ON PCB YM YX L=5,1 90° V L=9,1 ON L=3,0 YC PF L=1,2 Press fit USE PCB VL L=4,5 STRAIGHT SMT T TL L=2,25 L=3,35 90° SMT R C CRIMP S L=0,9 Gauge 22 Gauge 24-28 V VL T TL R C S L=3,0 L=4,5 L=2,25 L=3,35 L=0,9 Gauge 22 Gauge 24-28 Y YL YM YX V VL T TL R C S L=3,0 L=4,5 L=5,1 L=9,1 L=3,0 L=4,5 L=2,25 L=3,35 L=0,9 Gauge 22 Gauge 24-28 Y YL L=3,0 L=4,5 YC PF L=1,2 Press fit V VL T TL R C S L=3,0 L=4,5 L=2,25 L=3,35 L=0,9 Gauge 22 Gauge 24-28 Y YL YM YX V VL R C S L=3,0 L=4,5 L=5,1 L=9,1 L=3,0 L=4,5 L=0,9 Gauge 22 Gauge 24-28 Y YL PF V VL C S L=3,0 L=4,5 Press fit L=3,0 L=4,5 Gauge 22 Gauge 24-28 Y YL YM YX V VL C S L=3,0 L=4,5 L=5,1 L=9,1 L=3,0 L=4,5 Gauge 22 Gauge 24-28 Y YL PF V VL C S L=3,0 L=4,5 Press fit L=3,0 L=4,5 Gauge 22 Gauge 24-28 L=6,50 / 8,00 / 10,50 / 12,00 / 14,50 / 16,00 mm upon request (only for straight on pcb male contacts) Standard contact Any other type of contact upon request only 7 HF : high frequency contacts (series 30) Female Male PRESENTATION Straight PCB 90° PCB Straight SMT 90° SMT Card edge Straight Crimp 90° Crimp Type D Straight solder 90° solder Type E INFORMATION TABLE CMM RANGE TYPE OF CONTACTS TO BE USED IN THE TYPICAL USE CMM CONNECTOR WITH HF/HP CONTACTS ONLY TYPE E FOR SPECIAL CONTACTS ON Straight Crimp 90° Crimp Straight solder CAVITIES FOR TYPE D FOR SPECIAL CONTACTS ON PCB (Eg.221D00F22-00 nbr of special contact-1300CMM) Straight on PCB 90° on PCB Straight SMT 90° SMT Card edge CABLE 90° solder Male 100/200 Female Male 30-1300-CMM 30-1300-45 30-1400-CMM 30-1400-45 L=3,0 L=4,5 L=3,0 L=4,5 30-1600 30-1500-CMM no LF contact 30-1500-12 220 Female Male 30-2300-CMM 30-2300-45 30-2400-CMM 30-2400-45 L=3,0 L=4,5 L=3,0 L=4,5 30-1300-CMM 30-1300-45 30-1400-CMM 30-1400-45 L=3,0 L=4,5 L=3,0 L=4,5 30-2300-12 30-2300-14 30-2400-CMM 30-2400-45 L=3,0 L=4,5 L=3,0 L=4,5 320 Female 30-2600 30-1500-12 30-13XX-SS 30-13XX-DS 30-14XX-ZS 30-14XX-DS xx=cable type xx=cable type 30-23XX-SS 30-23XX-DS 30-24XX-ZS 30-24XX-DS xx=cable type xx=cable type 30-13XX-SS 30-13XX-DS 30-14XX-ZS 30-14XX-DS xx=cable type xx=cable type 30-23XX-SS 30-23XX-DS 30-24XX-ZS 30-24XX-DS xx=cable type xx=cable type 30-13XX-ZZ 30-14XX-ZZ xx=cable type xx=cable type 30-23XX-ZZ 30-24XX-ZZ xx=cable type xx=cable type 30-13XX-ZZ 30-14XX-ZZ xx=cable type xx=cable type 30-23XX-ZZ 30-24XX-ZZ xx=cable type xx=cable type Male 340 Female Standard contact Any other type of contact upon request only XX = 12, 20, 24, 26 Eg. 24 = cable Ø 2,4 XX = 20 or 26 for DS cable XX = 47, 85 Eg. 47 for UT47 cable Central contact “S” = crimp “Z” = solder - { 30 - Shield “S” = crimp “Z” = solder Double shield “DS” 8 HP : high power contacts (series 30) Female Male PRESENTATION Straight PCB 90° PCB Straight SMT 90° SMT 90° SMT Card edge Straight Crimp 90° Crimp Type D Straight solder 90° solder Type E INFORMATION TABLE CMM RANGE TYPE TYPICAL USE CMM CONNECTOR WITH CAVITIES FOR HF/HP CONTACTS ONLY TYPE D FOR SPECIAL CONTACTS ON PCB TYPE E FOR SPECIAL CONTACTS ON CABLE 90° on PCB Straight SMT 90° SMT 90° SMT Card edge Straight Crimp 90° Crimp Straight solder 90° solder OF CONTACTS TO BE USED IN THE Straight on PCB Male 100/200 Female Male 30-3300-CMM 30-3300-45 30-3400-CMM 30-3400-45 L=3,0 L=4,5 L=3,0 L=4,5 30-4300-CMM 30-4300-45 30-4400-CMM 30-4400-45 L=3,0 L=4,5 L=3,0 L=4,5 30-3300-CMM 30-3300-45 30-3400-CMM 30-3400-45 L=3,0 L=4,5 L=3,0 L=4,5 30-4300-12 30-4300-14 30-4400-CMM 30-4400-45 L=3,0 L=4,5 L=3,0 L=4,5 30-3600 30-3500 30-4600 30-4500 30-3500-CMM no LF contact 30-3500-12 30-33XX 30-33XX 30-43XX 30-43XX 30-33XX 30-33XX 30-43XX 30-43XX 220 Female Male 30-3500-12 320 Female Male 340 Female Standard contact Any other type of contact upon request only XX = 05, 08… Eg. 08 for 8A Please refer to page 94 9 HF : high frequency contacts (series 22) Female Male PRESENTATION Straight PCB 90° PCB Straight SMT 90° SMT Straight Crimp Type D 90° Crimp Straight solder 90° solder Type E INFORMATION TABLE CMM RANGE TYPE TYPICAL USE CMM CONNECTOR WITH TYPE D FOR SPECIAL CONTACTS ON PCB 90° on PCB Straight SMT 90° SMT OF CONTACTS TO BE USED IN THE Straight on PCB HF/HP CONTACTS ONLY TYPE E FOR SPECIAL CONTACTS ON CABLE Straight Crimp 90° Crimp Straight solder 90° solder CAVITIES FOR Male 100/200 Female Male 220 Female Male 320 Female Male 22-1300-12 22-1300-14 L=3,0 L=4,5 22-2300-12 22-2300-14 L=3,0 L=4,5 340 Female 22-1400-12* 22-1400-14* 22-1400-22** 22-1400-24** L=3,0 22-2400-12* 22-2400-14* 22-2400-22** 22-2400-24** L=3,0 22-1312-ZS 22-1320-ZZ 22-2312-ZS 22-2320-ZZ 12 = cable Ø 1,2 20 = cable Ø 2,0 L=4,5 L=4,5 Standard contact Any other type of contact upon request only * First row : 22-1400-12 / 22-1400-14 / 22-2400-12 / 22-2400-14 ** Second row : 22-1400-22 / 22-1400-24 / 22-2400-22 / 22-2400-24 10 When a two-row connector mixes a 22-2400-12 and a 22-2400-22 contact, the P/N of the HF contact changes to 2400-02. When a two-row connector mixes a 22-1400-12 and a 22-1400-22 contact, the P/N of the HF contact changes to 1400-02. When a two-row connector mixes a 22-2400-14 and a 22-2400-24 contact, the P/N of the HF contact changes to 2400-04. When a two-row connector mixes a 22-1400-14 and a 22-1400-24 contact, the P/N of the HF contact changes to 1400-04. HP : high power contacts (series 22) Female Male PRESENTATION Straight PCB 90° PCB Straight SMT 90° SMT Straight Crimp 90° Crimp Type D Straight solder 90° solder Type E INFORMATION TABLE CMM RANGE TYPE TYPICAL USE CMM CONNECTOR WITH TYPE D FOR SPECIAL CONTACTS ON PCB 90° on PCB Straight SMT 90° SMT OF CONTACTS TO BE USED IN THE Straight on PCB HF/HP CONTACTS ONLY TYPE E FOR SPECIAL CONTACTS ON Straight Crimp 90° Crimp Straight solder CAVITIES FOR CABLE 90° solder Male 100/200 Female Male 220 Female Male 320 Female Male 22-3300-12 22-3300-14 L=3,0 L=4,5 22-4300-12 22-4300-14 L=3,0 L=4,5 340 Female 22-3400-12* 22-3400-14* 22-3400-22** 22-3400-24** L=3,0 22-4400-12* 22-4400-14* 22-4400-22** 22-4400-24** L=3,0 22-33XX 22-33XX 22-43XX 22-43XX L=4,5 L=4,5 Standard contact Any other type of contact upon request only * First row : 22-3400-12 / 22-3400-14 / 22-4400-12 / 22-4400-14 ** Second row : 22-3400-22 / 22-3400-24 / 22-4400-22 / 22-4400-24 XX = 05, 08, 10 10 = 10A Please refer to page 102 When a two-row connector mixes a 22-3400-12 and a 22-3400-22 contact, the P/N of the HF contact changes to 3400-02. When a two-row connector mixes a 22-4400-12 and a 22-4400-22 contact, the P/N of the HF contact changes to 4400-02. When a two-row connector mixes a 22-3400-14 and a 22-3400-24 contact, the P/N of the HF contact changes to 3400-04. When a two-row connector mixes a 22-4400-14 and a 22-4400-24 contact, the P/N of the HF contact changes to 4400-04. 11 Male housing marking CMM 100/200 Marking : NCM (Nicomatic) + date code (Lot number) CMM 220 Marking 1 : NCM (Nicomatic) + date code (Lot number) Marking on two faces if the number Connector P/N of LF contacts is < to 10. LF contact number 1 Marking 2 : NCM (Nicomatic) + date code (Lot number) : CMM 220 mixed layout (LF + HF/HP) (as for CMM 100/200) CMM 220 with HF/HP contacts CMM 220 with 04 LF contacts Marking LF contacts type : Y-YL-V-VL-R-T-S-C (LF contacts only) CMM 320/340 Marking 1 : NCM (Nicomatic) / date code (Lot number) Connector P/N LF contact number 1 (LF contacts only) Marking 2 : NCM (Nicomatic) / date code (Lot number) : CMM 320 mixed layout CMM 320 with HF/HP contacts CMM 340 Marking LF contacts type : Y-YL-V-VL-S-C (as for CMM 100/200) 12 Female housing marking CMM 100/200 Marking : NCM (Nicomatic) + date code (Lot number) CMM 220 Marking 1 : NCM (Nicomatic) + date code (Lot number) Marking on two faces if the number Connector P/N of LF contacts is < to 10. LF contact number 1 Marking 2 : NCM (Nicomatic) + date code (Lot number) : CMM 220 mixed layout (LF + HF/HP) (as for CMM 100/200) CMM 220 with HF/HP contacts CMM 220 with 04 LF contacts Marking LF contacts type : Y-YL-V-VL-R-T-S-C-PF (LF contacts only) CMM 320/340 Marking 1 : NCM (Nicomatic) / date code (Lot number) Connector P/N LF contact number 1 Marking 2 : NCM (Nicomatic) / date code (Lot number) : CMM 320 mixed layout HF/HP contacts (as for CMM 100/200) CMM 320 with HF/HP contacts CMM 340 Marking LF contacts type : Y-YL-V-VL-S-C-PF (LF contacts only) 13 Nicomatic CMM part Code with Low Frequency contacts only Series Gender Termination Style Number of LF contacts 3 rows 3 rows 2 rows 2 rows 1 row n 10 20 n Fixing Hardware n Additional code for mixed-layout connector (HF/HP) Number of HF/HP contacts pin 1 side (LF contact number 1) y y With Latch 1 male Refer to table 02 to 25 page 22 (nn) on page 7 2 female Without Latch With Latch 1 male Refer to table 04 to 50 page 22 (nn) on page 7 2 female Without Latch z HF/HP Contact Type z No HF / HP contacts Depends upon the number of LF contacts Refer to table 04 to 60 Refer to pages If use with shifted central key, please refer to page 38 (nn) 43 to 46 on page 7 HF / HP : 15 contacts max. 2 female Type of HF/HP contact : please refer to pages 8-9 1 male 22 Refer to table 006 to 120 Refer to pages (nnn) 69 to 74 on page 7 32 34 Coaxmatic™ 30 Depends upon the number of LF contacts 1 male 2 female HF / HP : 20 contacts max. Type of HF/HP contact : please refer to pages 8-9 1 male Depends upon the number of LF contacts Refer to Refer to table the series Refer to pages 320 69 to 74 on page 7 (nnn) 2 female HF / HP : 64 contacts max. Type of HF/HP contact : please refer to pages 10-11 Note : For any configuration outside of this part numbering system, please contact us. 14 Number of HF/HP contacts opposite to LF contact number 1 Coaxmatic™ 30 Coaxmatic™ 22 numbering system CMM 100/200 Series p. 17 to 25 CMM 220 Series p. 27 to 46 CMM 320 Series p. 47 to 59 CMM 340 Series p. 60 to 74 High Frequency and High Power contacts p. 75 to 102 (HF) (HP) Tools and accessories p. 103 to 112 Cable instructions & assembly p. 113 to 122 15 16 CMM 100 / 200 PART NUMBERING REMINDER Code with Low Frequency contacts only Series Gender Termination Style Number of LF contacts 2 rows 1 row n 10 20 Fixing Hardware n With Latch “L”, 1 male Refer to table 02 to 25 “FL”, “LS” page 22 on page 7 2 female Without Latch “ ” With Latch “L”, 1 male Refer to table 04 to 50 “FL”, “LS” page 22 on page 7 2 female Without Latch “ ” 17 Configuration CMM 100 CONNECTOR SPACING without latch only without latch only CONTACTS POSITIONS 18 Configuration CMM 200 CONNECTOR SPACING without latch only without latch only CONTACTS POSITIONS 19 CMM 100 / 200 male STRAIGHT PCB Part numbering : “1” = Series 100 “2” = Series 200 Type : Y-YL nn 01 “L”, “FL” = with latch page 22 “ ” = without latch nn = number of LF contacts Type L Y 3 YL 4,5 Calculation : CMM 100 CMM 200 A = (nn x 2) - 2 A = nn - 2 B = A + 4,7 B = A + 4,7 C = A + 5,4 C = A + 5,4 Refer to dimension table on cover page nn min = 02 nn max = 25 nn min = 04 nn max = 50 nn min = 02 nn max = 25 nn min = 04 nn max = 50 90° PCB Part numbering : “1” = Series 100 “2” = Series 200 Type :V-VL nn 01 “L”, “FL” = with latch page 22 “ ” = without latch nn = number of LF contacts Type L V 3 VL 4,5 Calculation : CMM 100 CMM 200 A = (nn x 2) - 2 A = nn - 2 B = A + 4,7 B = A + 4,7 C = A + 5,4 C = A + 5,4 Refer to dimension table on cover page 20 CMM 100 / 200 male STRAIGHT SMT Part numbering : “1” = Series 100 “2” = Series 200 Type :T-TL 01 nn “LS”, “L”, “FL” = with latch page 22 “ ” = without latch nn = number of LF contacts Calculation : CMM 100 CMM 200 A = (nn x 2) - 2 A = nn - 2 C = A + 5,4 C = A + 5,4 Refer to dimension table on cover page nn min = 02 nn max = 25 nn min = 04 nn max = 50 nn min = 02 nn max = 25 nn min = 04 nn max = 50 90° SMT Part numbering : “1” = Series 100 “2” = Series 200 01Rnn “LS”, “L”, “FL” = with latch page 22 “ ” = without latch nn = number of LF contacts Calculation : CMM 100 CMM 200 A = (nn x 2) - 2 A = nn - 2 C = A + 5,4 C = A + 5,4 Refer to dimension table on cover page 21 CMM 100 / 200 male CRIMP Part numbering : “1” = Series 100 “2” = Series 200 Type : S-C nn 01 “L”, “FL” = with latch page 22 “ ” = without latch Type Gauge S 24-28 C 22 nn = number of LF contacts Calculation : CMM 100 CMM 200 A = (nn x 2) - 2 A = nn - 2 C = A + 5,4 C = A + 5,4 Refer to dimension table on cover page nn min = 02 nn max = 25 nn min = 04 nn max = 50 RETENTION LATCHES FOR CMM 100 / 200 MALE Straight latch with locking “L” Straight latch without locking “FL” Latch for CMM connector with T termination style “LS” Latch for CMM connector with R termination style “LS” The strain relief straps are supplied with all male CMM 100 / 200 connectors mounted with latches L or FL type except for Y & YL terminations 22 PCB Thickness P/N < 2,5 mm 13218 V Termination style Y T/TL R > 2,5 mm 13816 VL YL T/TL R If no strain relief straps with your connector, please order under P/Ns on the left CMM 100 / 200 female STRAIGHT PCB Part numbering : “1” = Series 100 “2” = Series 200 nn 02 Type : Y-YL Type L Y 3 YL 4,5 nn = number of LF contacts Calculation : CMM 100 CMM 200 A = (nn x 2) - 2 A = nn - 2 B =A + 5 B =A + 5 Refer to dimension table on cover page nn min = 02 nn max = 25 nn min = 04 nn max = 50 nn min = 02 nn max = 25 nn min = 04 nn max = 50 90° PCB Part numbering : “1” = Series 100 “2” = Series 200 nn 02 Type :V-VL Type L V 3 VL 4,5 nn = number of LF contacts Calculation : CMM 100 CMM 200 A = (nn x 2) - 2 A = nn - 2 B =A + 5 B =A + 5 Refer to dimension table on cover page 23 CMM 100 / 200 female STRAIGHT SMT Part numbering : “1” = Series 100 “2” = Series 200 nn 02 Type : T-TL nn = number of LF contacts Calculation : CMM 100 CMM 200 A = (nn x 2) - 2 A = nn - 2 B =A + 5 B =A + 5 Refer to dimension table on cover page Optional: Packaging in reel available upon request nn min = 02 nn max = 25 nn min = 04 nn max = 50 nn min = 02 nn max = 25 nn min = 04 nn max = 50 CRIMP Part numbering : “1” = Series100 “2” = Series 200 nn 02 Type : S-C nn = number of LF contacts Type Gauge S 24-28 C 22 Calculation : CMM 100 CMM 200 A = (nn x 2) - 2 A = nn - 2 B =A + 5 B =A + 5 Refer to dimension table on cover page 24 CMM 100 / 200 female STRAIGHT PRESS FIT Part numbering : “1” = Series 100 “2” = Series 200 0 2 PF n n nn = number of LF contacts Calculation : CMM 100 CMM 200 A = (nn x 2) - 2 A = nn - 2 B =A + 5 B =A + 5 Refer to dimension table on cover page nn min = 02 nn max = 25 nn min = 04 nn max = 50 nn min = 02 nn max = 25 nn min = 04 nn max = 50 90° SMT Part numbering : “1” = Series 100 “2” = Series 200 02 R nn nn = number of LF contacts Optional: Packaging in reel available upon request Upon request only 25 26 CMM 220 with LF contacts PART NUMBERING REMINDER Code with Low Frequency contacts only Series Gender Termination Style Number of LF contacts 2 rows n Fixing Hardware n 1 male Refer to pages Refer to table 04 to 60 43 to 46 on page 7 22 2 female 27 CMM 220 Configuration CONNECTOR SPACING CONTACTS POSITIONS 28 CMM 220 male STRAIGHT PCB nn min = 04 nn max = 60 Part numbering : Type : Y-YL nn 221 See Fixing on page 43, 44 “Fxx” without fixing nn = number of LF contacts Type L Y 3 YL 4,5 Calculation : A = nn - 2 B =A + 7 C = A + 12 Refer to dimension table on cover page 90° PCB nn min = 04 nn max = 60 Part numbering : Type : V-VL nn 221 See Fixing on page 43, 44 “Fxx” without fixing nn = number of LF contacts Type L V 3 VL 4,5 Calculation : A = nn - 2 B =A + 7 C = A + 12 Refer to dimension table on cover page 29 CMM 220 male STRAIGHT SMT nn min = 04 nn max = 60 Part numbering : Type : T-TL 221 nn See Fixing on page 43, 44 “Fxx” without fixing nn = number of LF contacts Optional: Packaging in reel available upon request Calculation : A = nn - 2 B =A + 7 C = A + 12 Refer to dimension table on cover page 90° SMT nn min = 04 nn max = 60 Part numbering : 221Rnn See Fixing on page 43, 44 “Fxx” without fixing nn = number of LF contacts Optional: Packaging in reel available upon request Calculation : A = nn - 2 B =A + 7 C = A + 12 Refer to dimension table on cover page 30 CMM 220 male CRIMP nn min = 04 nn max = 60 Part numbering : Type : S-C nn 221 See Fixing on page 43, 44 “Fxx” without fixing nn = number of LF contacts Type Gauge S 24-28 C 22 Calculation : A = nn - 2 B =A + 7 C = A + 12 Refer to dimension table on cover page 31 CMM 220 female STRAIGHT PCB nn min = 04 nn max = 60 Part numbering : Type : Y-YL nn 222 See Fixing on page 45-46 “Mxx” without fixing nn = number of LF contacts Type L Y 3 YL 4,5 Calculation : A = nn - 2 B =A + 7 C = A + 12 Refer to dimension table on cover page 90° PCB nn min = 04 nn max = 60 Part numbering : Type : V-VL nn 222 See Fixing on page 45 “Mxx” without fixing nn = number of LF contacts Type L V 3 VL 4,5 Calculation : A = nn - 2 B =A + 7 C = A + 12 Refer to dimension table on cover page 32 CMM 220 female STRAIGHT SMT nn min = 04 nn max = 60 Part numbering : Type : T-TL 222 nn See Fixing on page 45-46 “Mxx” without fixing nn = number of LF contacts Optional: Packaging in reel available upon request Calculation : A = nn - 2 B =A + 7 C = A + 12 Refer to dimension table on cover page 90° SMT nn min = 04 nn max = 60 Part numbering : 222Rnn See Fixing on page 45 “Mxx” without fixing nn = number of LF contacts Optional: Packaging in reel available upon request Calculation : A = nn - 2 B =A + 7 C = A + 12 Refer to dimension table on cover page 33 CMM 220 female STRAIGHT PRESS FIT nn min = 04 nn max = 60 Part numbering : 2 2 2 PF n n See Fixing on page 45-46 “Mxx” without fixing nn = number of LF contacts Calculation : A = nn - 2 B =A + 7 C = A + 12 Refer to dimension table on cover page CRIMP nn min = 04 nn max = 60 Part numbering : Type : S-C nn 222 See Fixing on page 45-46 “Mxx” without fixing nn = number of LF contacts Type Gauge S 24-28 C 22 Calculation : A = nn - 2 B =A + 7 C = A + 12 Refer to dimension table on cover page 34 CMM 220 mixed-layout PART NUMBERING REMINDER Code with Low Frequency contacts only Series Gender Termination Style Number of LF contacts 2 rows n Fixing Hardware n 1 male Refer to pages Refer to table 04 to 60 43 to 46 on page 7 22 2 female Additional code for mixed-layout connector (HF/HP) Number of HF/HP contacts pin 1 side (LF contact number 1) y y Number of HF/HP contacts opposite to LF contact number 1 z HF/HP Contact Type z Depends upon the number of LF contacts If use with shifted central key, please refer to page 42 HF / HP : 15 contacts max. Type of HF/HP contact : please refer to pages 8-9 HP/HF 30 please refer to pages 75 to 94 35 CMM 220 Male mixed-layout STRAIGHT PCB Part numbering : Number of contacts LF pin 1 side 221 nn Type : Y-YL Number of contacts opposite side LF pin 1 - y y z z See Fixing on page 43, 44 “Fxx” without fixing HF or HP P/N refer to page 75 nn = number of LF contacts Type L Y 3 YL 4,5 Pattern for special contact : A = nn - 2 B = {(yy+zz)x4} + A + 7 Bmax. = 65 mm C=B+5 STRAIGHT PCB FOR HP/HF CONTACTS ONLY Part numbering : Number of HF or HP contacts 221D00 - 00 z z - See Fixing on page 43, 44 “Fxx” without fixing HF or HP P/N refer to page 75 Pattern for special contact : A = (zz x 4) - 4 B =A + 9 C=B+5 Refer to dimension table on cover page 36 Special contacts min. : 02 max. : 15 CMM 220 Male mixed-layout 90° PCB Part numbering : Number of contacts LF pin 1 side 221 nn Type : V-VL Number of contacts opposite side LF pin 1 - y y z z See Fixing on page 43, 44 “Fxx” without fixing HF or HP P/N refer to page 75 nn = number of LF contacts Type L V 3 VL 4,5 Pattern for special contact : A = nn - 2 B = {(yy+zz)x4} + A + 7 Bmax. = 65 mm C=B+5 90° PCB FOR HP/HF CONTACTS ONLY Part numbering : Number of HF or HP contacts 221D00 - 00 z z - See Fixing on page 43, 44 “Fxx” without fixing HF or HP P/N refer to page 75 Pattern for special contact : A = (zz x 4) - 4 B =A + 9 C=B+5 Special contacts min. : 02 max. : 15 Refer to sizes information table on cover page 37 CMM 220 Male mixed-layout CRIMP Part numbering : Number of contacts LF pin 1 side 221 nn Type : S-C Number of contacts opposite side LF pin 1 - y y z z See Fixing on page 43, 44 “Fxx” without fixing HF or HP P/N refer to page 75 nn = number of LF contacts Type Gauge S 24-28 C 22 A = nn - 2 B = {(yy+zz)x4} + A + 7 Bmax. = 65 mm C=B+5 CRIMP FOR HP/HF CONTACTS ONLY Part numbering : Number of HF or HP contacts 221 E 00 - 00 z z - See Fixing on page 43, 44 “Fxx” without fixing HF or HP P/N refer to page 75 A = (zz x 4) - 4 B =A + 9 C=B+5 Refer to dimension table on cover page 38 Special contacts min. : 02 max. : 15 CMM 220 Female mixed-layout STRAIGHT PCB Part numbering : Number of contacts LF pin 1 side 222 nn Type : Y-YL Number of contacts opposite side LF pin 1 - y y z z See Fixing on page 45 “Mxx” without fixing HF or HP P/N refer to page 75 nn = number of LF contacts Type L Y 3 YL 4,5 Pattern for special contact : A = nn - 2 B = {(yy+zz)x4} + A + 7 Bmax. = 65 mm C=B+5 STRAIGHT PCB FOR HP/HF CONTACTS ONLY Part numbering : Number of HF or HP contacts 222D00 - 00 z z - See Fixing on page 45 “Mxx” without fixing HF or HP P/N refer to page 75 Pattern for special contact : Special contacts min. : 02 max. : 15 A = (zz x 4) - 4 B =A + 9 C=B+5 Refer to dimension table on cover page 39 CMM 220 Female mixed-layout 90° PCB Part numbering : Number of contacts LF pin 1 side 222 nn Type : V-VL Number of contacts opposite side LF pin 1 - y y z z See Fixing on page 45 “Mxx” without fixing HF or HP P/N refer to page 75 nn = number of LF contacts Type L V 3 VL 4,5 Pattern for special contact : A = nn - 2 B = {(yy+zz)x4} + A + 7 Bmax. = 65 mm C=B+5 90° PCB FOR HP/HF CONTACTS ONLY Part numbering : Number of HF or HP contacts 222D00 - 00 z z - See Fixing on page 45 “Mxx” without fixing HF or HP P/N refer to page 75 Pattern for special contact : A = (zz x 4) - 4 B =A + 9 C=B+5 Refer to dimension table on cover page 40 Special contacts min. : 02 max. : 15 CMM 220 Female mixed-layout CRIMP Part numbering : Number of contacts LF pin 1 side 222 nn Type : S-C Number of contacts opposite side LF pin 1 - y y z z See Fixing on page 45 “Mxx” without fixing HF or HP P/N refer to page 75 nn = number of LF contacts Type Gauge S 24-28 C 22 A = nn - 2 B = {(yy+zz)x4} + A + 7 Bmax. = 65 mm C=B+5 CRIMP FOR HP/HF CONTACTS ONLY Part numbering : Number of HF or HP contacts 222 E 00 - 00 z z - See Fixing on page 45 “Mxx” without fixing HF or HP P/N refer to page 75 A = (zz x 4) - 4 B =A + 9 C=B+5 Special contacts min. : 02 max. : 15 Refer to dimension table on cover page 41 Part numbering with shifted polarization key position PART NUMBERING Digits to be added 2 2 n n - y y z z - Number of LF contacts nn min. = 06 (k = - k l l Polarized key direction shifted from the housing center (k = 1 direction of contact LF number 1) 2 opposite direction to LF contact number 1) Polarized key shift value compared to the housing center (each shift = 2 mm) EXPLANATION 221 2 4 Fxx - 2 0 4 221 1 0 Fxx - 0 2 0 3 - - 103 221 0 0 Fxx - 0 0 1 1 - - 103 EXAMPLES 42 221 1 0 Fxx - 0 2 0 3 - - 103 221 0 0 Fxx - 0 0 1 1 - - 103 222 1 0 Mxx - 0 2 0 3 - - 103 222 0 0 Mxx - 0 0 1 1 - - 103 Fixing hardware interconnection table for CMM 220 Straight F22 F22H OK OK OK OK F24 F24H OK OK OK OK F63 OK OK OK OK OK OK OK OK OK OK A A A A F63L F27 F34 F21 F60 F61 F62 F62H OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK A A 0,8 min 1,5 min 6 2 max 4 max max F22 F24 OK OK OK OK OK OK OK OK 4 max F24L F25 F26 F23 OK OK OK OK OK OK OK OK OK OK OK OK 2,5 4,5 1,6 3,2 max max max max F30 F30H OK OK OK OK F31 F63 F63L F2xx F31H OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK A A A A F21 F60 F61 F62 F28 OK OK OK OK OK OK OK OK A A OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK 1,5 min. M12L 4 max. M49 OK OK OK OK OK OK OK OK OK M1xx OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK B B OK OK OK OK Racking With cover Contacts on cable 90° Straight No fixing on PCB 220 Floating 2,5 4,5 1,6 3,2 max. max. max. max. F24L F25 F26 F30 F31 F23 F30H F31H OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK 1,5 min. 2,5 max. 1,5 min. 4 max. 4 max. Racking 0,8 min. 1,5 min. 6 2 max. 4 max. max. OK Floating 90° With cover Without Locked Straight Contacts on cable Smooth Without 90° Locked Straight Straight Fixing 0,8 min. M12 2 max. M12H M12L 1,5 min. M12LH 4 max. M49 M49H 1,5 min. M46 2,5 max. M46H 1,5 min. M47 4 max. M47H M21 1,6 3,2 M21L 1,6 M48 M48M 2 M48L 3,2 M16 M11 0,8 min. M12 2 max. Straight CMM SERIES No fixing on PCB Housing assembly Smooth PCB Contacts 220 CMM SERIES FEMALE CONNECTORS PCB thickness (mm) PCB Contacts 90° Card edge only HF Card edge HF & LF MALE CONNECTORS Type of contact in connector Type of PCB mount OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK M46 OK OK OK OK OK OK M47 OK OK OK OK OK OK 1,6 M21 OK OK OK A A A OK OK OK A A A OK OK 3,2 M21L OK OK OK A A A OK OK OK A A A OK OK 1,6 M48 OK OK 2 M48M OK OK 3,2 M48L OK OK B B M16 M11 OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK M18 OK OK OK B B B OK OK OK OK OK OK B B B OK OK OK Make it a habit! Use easy & automatic configurators for CMM micro-connectors single part and mating-half construction on www.nicomatic.com. Recommended Torque : 0,2 N/m Except 0,4 N/m for M46/M47 FIXING HARDWARE FOR CMM 220 MALE REFERENCE ASSEMBLY ON PCB OVERALL DIMENSIONS RECOMMENDATION F27 F27 : CMM male : Card edge for HF contact 30-1500-CMM F34 F34 : CMM male : Card edge LF contact or mixed F28 : CMM male : S-C (E : straight) F28 Please refer to the CMM Catalogue Guidelines for any other fixing not listed here. 43 Fixing for CMM 220 male FIXING HARDWARE FOR CMM 220 MALE REFERENCE ASSEMBLY ON PCB OVERALL DIMENSIONS RECOMMENDATION Straight on PCB F21 : CMM male : Y-YL-T-S-C (D-E : straight) F21 F22 : CMM male : Y-T-S-C (D-E : straight) Straight on PCB 0,8 min / 2 max F22 F22H : CMM male : Y-T (D : straight) F22H F24 : CMM male : YL-T-S-C (D-E : straight) Straight on PCB 1,5 min / 4 max F24 F24H : CMM male : YL-T (D : straight) F24H Straight on PCB 6 max F24L : CMM male : T-TL (D-E : straight) F24L F2xx xx = (PCB thickness + 0,2 mm) x 10 Example : for 3 mm PCB, the reference is F232 (3 + 0,2) x 10 = 32 xx = 32 Straight on PCB with floating option F2xx : CMM male : S-C (E : straight) 90° on PCB F25 : CMM male : V-VL-R-S-C-E (D : 90°) F25 90° on PCB F26 F26/F23 : CMM male : V-VL-R-S-C-E (D : 90°) F23 90° on PCB 2,5 max. F30 F30 & F30H: CMM male : V-R-C-S-E (D : 90°) F30H 90° on PCB 4,5 max. F31 F31H Please refer to the CMM Catalogue Guidelines for any other fixing not listed here. 44 F31 & F31H: CMM male : VL-R-C-S-E (D : 90°) Fixing for CMM 220 female FIXING HARDWARE FOR CMM 220 FEMALE HEXAGONAL REFERENCE STANDARD NUT ASSEMBLY ON "W" NUT PCB OVERALL CODE FOR ADDITIONAL WASHER DIMENSIONS RECOMMENDATION Straight on PCB M16 M16/M11 : CMM Female : Y-YL-T-S-C-E (D : straight) M11 Straight on PCB 0,8 min / 2 max M12 : CMM female : Y-T-S-C (D-E : straight) M12 M12H : CMM female : Y-T (D : straight) M12H Straight on PCB 1,5 min / 4 max M12L M12LH : CMM female : YL-T (D : straight) M12LH M1xx xx = (PCB Straight on PCB with floating option thickness + 0,2 mm) x 10 Example : for 3 mm PCB, the reference is M132 (3 + 0,2) x 10 = 32 xx = 32 M21 for PCB 1,6 mm (L = 4 mm) M12L : CMM female : Y-T-S-C (D-E : straight) M1xx : CMM female : S-C (E : straight) 90° on PCB M21 : CMM Female : V-R-S-C-E (D : 90°) M21L : CMM Female : VL-R-S-C-E (D : 90°) M21L for PCB 3,2 mm (L = 5 mm) Cover option M18 : CMM female : S-C (E : straight) M18 Please refer to the CMM Catalogue Guidelines for any other fixing not listed here. 45 Other fixing hardware for CMM 220 FIXING HARDWARE FOR CMM 220 FEMALE/MALE REFERENCE ASSEMBLY ON PCB Straight on PCB 1,5 min. / 2,5 max. M46 OVERALL DIMENSIONS RECOMMENDATION M46 : CMM female : Y-T-S-C (D-E : straight) M46H : CMM female : Y-T (D : straight) M46H Straight on PCB 1,5 min. / 4 max. M47 M47 : CMM female : YL-T-S-C (D-E : straight) M47H : CMM female : YL-T (D : straight) M47H M48 for PCB 1,6 mm (L = 3 mm) 90° on PCB M48M for PCB 2 mm (L = 4 mm) M48 / M48M / M48L : CMM female : V-VL-R-S-C-E (D : 90°) M48L for PCB 3,2 mm (L = 5 mm) Straight on PCB M49 M49 : CMM female : Y-T-S-C (D-E : straight) M49H : CMM female : Y-T (D : straight) M49H Straight on PCB F60 : CMM male : Y-YL-T-S-C-E (D : straight) F60 Straight on PCB F61 : CMM male : Y-YL-T-S-C-E (D : straight) F61 Racking F62 F62H : CMM male : Y-T (D : straight) F62H 90° on PCB F63 for PCB 1,6 mm F63 : CMM male : V-R-S-C-E (D : 90°) F63L : CMM male : VL-R-S-C-E (D : 90°) F63L for PCB 3,2 mm M46 M46H M47 M47H 46 F62 : CMM male : Y-T-S-C (D-E : straight) CMM 320 with LF contacts PART NUMBERING REMINDER Code with Low Frequency contacts only Series Gender Termination Style Number of LF contacts Fixing Hardware 3 rows n n n 1 male Refer to pages Refer to table 006 to 120 69 to 74 on page 7 32 2 female 47 CMM 320 Configuration CONNECTOR SPACING CONTACTS POSITIONS 48 CMM 320 Male STRAIGHT PCB FOR LF CONTACTS ONLY Part numbering : Type : Y-YL nnn 321 See Fixing on pages 69 to 74 “Fxx” without fixing nnn = number of LF contacts Type L Y 3 YL 4,5 nnn min = 006 nnn max = 120 A= nnn x 2 -2 3 B =A + 9 C = A + 15 Refer to dimension table on cover page 90° PCB FOR LF CONTACTS ONLY Part numbering : Type : V-VL nnn 321 See Fixing on pages 69 to 74 “Fxx” without fixing nnn = number of LF contacts Type L V 3 VL 4,5 nnn min = 006 nnn max = 120 A= nnn x 2 -2 3 B =A + 9 C = A + 15 Refer to dimension table on cover page 49 CMM 320 Male 90° SMT FOR LF CONTACTS ONLY Part numbering : 321Rnnn See Fixing on pages 69 to 74 “Fxx” without fixing nnn = number of LF contacts Optional: Packaging in reel available upon request nnn min = 006 nnn max = 120 A= nnn x 2 -2 3 B =A + 9 C = A + 15 Refer to dimension table on cover page CRIMP FOR LF CONTACTS ONLY Part numbering : Type : S-C 321 nnn See Fixing on pages 69 to 74 “Fxx” without fixing nnn = number of LF contacts Type Gauge S 24-28 C 22 nnn min = 006 nnn max = 120 A= nnn x 2 -2 3 B =A + 9 C = A + 15 Refer to dimension table on cover page 50 CMM 320 Female STRAIGHT PCB FOR LF CONTACTS ONLY Part numbering : Type : Y-YL nnn 322 See Fixing on pages 69 to 74 “Mxx” without fixing nnn = number of LF contacts Type L Y 3 YL 4,5 nnn min = 006 nnn max = 120 A= nnn x 2 -2 3 B =A + 9 C = A + 15 Refer to dimension table on cover page 90° PCB FOR LF CONTACTS ONLY Part numbering : Type : V-VL nnn 322 See Fixing on pages 69 to 74 “Mxx” without fixing nnn = number of LF contacts Type L V 3 VL 4,5 nnn min = 006 nnn max = 120 A= nnn x 2 -2 3 B =A + 9 C = A + 15 Refer to dimension table on cover page 51 CMM 320 Female CRIMP FOR LF CONTACTS ONLY Part numbering : Type : S-C 322 nnn See Fixing on pages 69 to 74 “Mxx” without fixing nnn = number of LF contacts Type Gauge S 24-28 C 22 nnn min = 006 nnn max = 120 A= nnn x 2 -2 3 B =A + 9 C = A + 15 Refer to dimension table on cover page 52 CMM 320 with mixed-layout PART NUMBERING REMINDER Code with Low Frequency contacts only Series Gender Termination Style Number of LF contacts Fixing Hardware 3 rows n n n Refer to table Refer to pages 006 to 120 on page 7 69 to 74 2 female Number of HF/HP contacts pin 1 side (LF contact number 1) y y Number of HF/HP contacts opposite to LF contact number 1 z HF/HP Contact Type z Depends upon the number of LF contacts 1 male 32 Additional code for mixed-layout connector (HF/HP) HF / HP : 20 contacts max. Type of HF/HP contact : please refer to pages 8-9 HF/HP 30 please refer to pages 75 to 94 53 CMM 320 Male mixed-layout STRAIGHT PCB Part numbering : Number of contacts LF pin 1 side nnn 321 Type : Y-YL Number of contacts opposite side LF pin 1 - y y z z See Fixing on pages 69 to 74 “Fxx” without fixing HF or HP P/N refer to page 75 nnn = number of LF contacts Type L Y 3 YL 4,5 Pattern for special contact : A= {(yy+zz)x4+nnn}x2 -2 3 B =A + 9 B max. = 87 C = A + 15 STRAIGHT PCB FOR HP/HF CONTACTS ONLY Part numbering : Number of HF or HP contacts 3 2 1D0 0 0 - 00 z z - See Fixing on pages 69 to 74 “Fxx” without fixing HF or HP P/N refer to page 75 Pattern for special contact : A = (zz x 4) - 4 B = A + 11 C = A + 17 54 Special contacts min. : 02 max. : 20 CMM 320 Male mixed-layout 90° PCB Part numbering : Number of contacts LF pin 1 side nnn 321 Number of contacts opposite side LF pin 1 - y y z z - See Fixing on pages 69 to 74 “Fxx” without fixing nnn = number of LF contacts Type : V-VL Type HF or HP P/N refer to page 75 L V 3 VL 4,5 Pattern for special contact : A= {(yy+zz)x4+nnn}x2 -2 3 B =A + 9 B max. = 87 C = A + 15 Special contacts mounted 90° PCB FOR HP/HF CONTACTS ONLY Part numbering : Number of HF or HP contacts 3 2 1D0 0 0 - 00 z z - See Fixing on pages 69 to 74 “Fxx” without fixing HF or HP P/N refer to page 75 Pattern for special contact : A = (zz x 4) - 4 B = A + 11 C = A + 17 Special contacts min. : 02 max. : 20 55 CMM 320 Male mixed-layout CRIMP Part numbering : Number of contacts LF pin 1 side 321 nnn Type : S-C Number of contacts opposite side LF pin 1 - y y z z See Fixing on pages 69 to 74 “Fxx” without fixing HF or HP P/N refer to page 75 nnn = number of LF contacts Type Gauge S 24-28 C 22 A= {(yy+zz)x4+nnn}x2 -2 3 B =A + 9 B max. = 87 C = A + 15 CRIMP FOR HP/HF CONTACTS ONLY Part numbering : Number of HF or HP contacts 321 E 00 0 - 00 z z - See Fixing on pages 69 to 74 “Fxx” without fixing HF or HP P/N refer to page 75 A = (zz x 4) - 4 B = A + 11 C = A + 17 56 Special contacts min. : 02 max. : 20 CMM 320 Female mixed-layout STRAIGHT PCB Part numbering : Number of contacts LF pin 1 side nnn 322 Type : Y-YL Number of contacts opposite side LF pin 1 - y y z z See Fixing on pages 69 to 74 “Mxx” without fixing HF or HP P/N refer to page 75 nnn = number of LF contacts Type L Y 3 YL 4,5 Pattern for special contact : A= {(yy+zz)x4+nnn}x2 -2 3 B =A + 9 B max. = 87 C = A + 15 STRAIGHT PCB FOR HP/HF CONTACTS ONLY Part numbering : Number of HF or HP contacts 3 2 2D0 0 0 - 00 z z - See Fixing on pages 69 to 74 “Mxx” without fixing HF or HP P/N refer to page 75 Pattern for special contact : A = (zz x 4) - 4 B = A + 11 C = A + 17 Special contacts min. : 02 max. : 20 57 CMM 320 Female mixed-layout 90° PCB Part numbering : Number of contacts LF pin 1 side nnn 322 Type : V-VL Number of contacts opposite side LF pin 1 - y y z z See Fixing on pages 69 to 74 “Mxx” without fixing HF or HP P/N refer to page 75 nnn = number of LF contacts Type L V 3 VL 4,5 Pattern for special contact : A= {(yy+zz)x4+nnn}x2 -2 3 B =A + 9 B max. = 87 C = A + 15 Special contacts mounted 90° PCB FOR HP/HF CONTACTS ONLY Part numbering : Number of HF or HP contacts 3 2 2D0 0 0 - 00 z z - See Fixing on pages 69 to 74 “Mxx” without fixing HF or HP P/N refer to page 75 Pattern for special contact : A = (zz x 4) - 4 B = A + 11 C = A + 17 58 Special contacts min. : 02 max. : 20 CMM 320 Female mixed-layout CRIMP Part numbering : Number of contacts LF pin 1 side 322 nnn Type : S-C Number of contacts opposite side LF pin 1 - y y z z See Fixing on pages 69 to 74 “Mxx” without fixing HF or HP P/N refer to page 75 nnn = number of LF contacts Type Gauge S 24-28 C 22 A= {(yy+zz)x4+nnn}x2 -2 3 B =A + 9 B max. = 87 C = A + 15 CRIMP FOR HP/HF CONTACTS ONLY Part numbering : Number of HF or HP contacts 322 E 00 0 - 00 z z - See Fixing on pages 69 to 74 “Mxx” without fixing HF or HP P/N refer to page 75 A = (zz x 4) - 4 B = A + 11 C = A + 17 Special contacts min. : 02 max. : 20 59 60 CMM 340 PART NUMBERING REMINDER Code with Low Frequency contacts only Series Gender Termination Style Number of LF contacts Fixing Hardware 3 rows n n n 1 male 34 2 female Additional code for mixed-layout connector (HF/HP) Number of HF/HP contacts pin 1 side (LF contact number 1) y y Number of HF/HP contacts opposite to LF contact number 1 z z Depends upon the number of LF contacts Refer to table Refer to Refer to pages the series 69 to 74 on page 7 320 HF/HP Contact Type HF / HP : 64 contacts max. Type of HF/HP contact : please refer to pages 10-11 HP/HF 22 please refer to pages 95 to 102 61 CMM 340 Configuration CONNECTOR SPACING CONTACTS POSITIONS 62 CMM 340 Male mixed-layout STRAIGHT PCB Part numbering : Number of contacts LF pin 1 side nnn 341 Type : Y-YL Number of contacts opposite side LF pin 1 - y y z z See Fixing on pages 69 to 74 “Fxx” without fixing HF or HP P/N refer to page 95 nnn = number of LF contacts Type L Y 3 YL 4,5 A= Pattern for special contact : { } (nnnx2) -2 3 if yy and zz ≠ 0 : B= {( )} (yy)+(zz) -2 x 2,5+14,5+A 2 if yy or zz = 0 : {( )} B = (yy)or(zz) -1 x 2,5+11,75+A 2 B max. = 87 C=B+6 STRAIGHT PCB FOR HP/HF CONTACTS ONLY Part numbering : Number of HF or HP contacts 3 4 1D0 0 0 - 00 z z - See Fixing on pages 69 to 74 “Fxx” without fixing HF or HP P/N refer to page 95 Pattern for special contact : ( ) A = (zzx2,5) -2,5 2 Special contacts min. : 04 max. : 64 B = A + 10 C=B+6 Refer to dimension table on cover page 63 CMM 340 Male mixed-layout 90° PCB Part numbering : Number of contacts LF pin 1 side nnn 341 Type : V-VL Number of contacts opposite side LF pin 1 - y y z z See Fixing on pages 69 to 74 “Fxx” without fixing HF or HP P/N refer to page 95 nnn = number of LF contacts Type L V 3 VL 4,5 A= Pattern for special contact : { } (nnnx2) -2 3 if yy and zz ≠ 0 : B= {( )} (yy)+(zz) -2 x 2,5+14,5+A 2 if yy or zz = 0 : {( )} B = (yy)or(zz) -1 x 2,5+11,75+A 2 B max. = 87 C=B+6 90° PCB FOR HP/HF CONTACTS ONLY Part numbering : Number of HF or HP contacts 3 4 1D0 0 0 - 00 z z - See Fixing on pages 69 to 74 “Fxx” without fixing HF or HP P/N refer to page 95 Pattern for special contact : Special contacts min. : 04 max. : 64 ( ) A = (zzx2,5) -2,5 2 B = A + 10 C=B+6 Refer to dimension table on cover page 64 CMM 340 Male mixed-layout CRIMP Part numbering : Number of contacts LF pin 1 side nnn 341 Type : S-C Number of contacts opposite side LF pin 1 - y y z z See Fixing on pages 69 to 74 “Fxx” without fixing HF or HP P/N refer to page 95 nnn = number of LF contacts Type Gauge S 24-28 C 22 A= { } (nnnx2) -2 3 if yy and zz ≠ 0 : B= {( )} (yy)+(zz) -2 x 2,5+14,5+A 2 if yy or zz = 0 : {( )} B = (yy)or(zz) -1 x 2,5+11,75+A 2 B max. = 87 C=B+6 CRIMP FOR HP/HF CONTACTS ONLY Part numbering : Number of HF or HP contacts 341 E 00 0 - 00 z z - See Fixing on pages 69 to 74 “Fxx” without fixing HF or HP P/N refer to page 95 ( ) A = (zzx2,5) -2,5 2 Special contacts min. : 04 max. : 64 B = A + 10 C=B+6 Refer to dimension table on cover page 65 CMM 340 Female mixed-layout STRAIGHT PCB Part numbering : Number of contacts LF pin 1 side nnn 342 Type : Y-YL Number of contacts opposite side LF pin 1 - y y z z See Fixing on pages 69 to 74 “Mxx” without fixing HF or HP P/N refer to page 95 nnn = number of LF contacts Type L Y 3 YL 4,5 A= Pattern for special contact : { } (nnnx2) -2 3 if yy and zz ≠ 0 : B= {( )} (yy)+(zz) -2 x 2,5+14,5+A 2 if yy or zz = 0 : {( )} B = (yy)or(zz) -1 x 2,5+11,75+A 2 B max. = 87 C=B+6 STRAIGHT PCB FOR HP/HF CONTACTS ONLY Part numbering : Number of HF or HP contacts 3 4 2D0 0 0 - 00 z z - See Fixing on pages 69 to 74 “Mxx” without fixing HF or HP P/N refer to page 95 Pattern for special contact : Special contacts min. : 04 max. : 64 ( ) A = (zzx2,5) -2,5 2 B = A + 10 C=B+6 Refer to dimension table on cover page 66 CMM 340 Female mixed-layout 90° PCB Part numbering : Number of contacts LF pin 1 side nnn 342 Type : V-VL Number of contacts opposite side LF pin 1 - y y z z See Fixing on pages 69 to 74 “Mxx” without fixing HF or HP P/N refer to page 95 nnn = number of LF contacts Type L V 3 VL 4,5 A= Pattern for special contact : { } (nnnx2) -2 3 if yy and zz ≠ 0 : B= {( )} (yy)+(zz) -2 x 2,5+14,5+A 2 if yy or zz = 0 : {( )} B = (yy)or(zz) -1 x 2,5+11,75+A 2 B max. = 87 C=B+6 90° PCB FOR HP/HF CONTACTS ONLY Part numbering : Number of HF or HP contacts 3 4 2D0 0 0 - 00 z z - See Fixing on pages 69 to 74 “Mxx” without fixing HF or HP P/N refer to page 95 Pattern for special contact : ( ) A = (zzx2,5) -2,5 2 Special contacts min. : 04 max. : 64 B = A + 10 C=B+6 Refer to dimension table on cover page 67 CMM 340 Female mixed-layout CRIMP Part numbering : Number of contacts LF pin 1 side nnn 342 Type : S-C Number of contacts opposite side LF pin 1 - y y z z See Fixing on pages 69 to 74 “Mxx” without fixing HF or HP P/N refer to page 95 nnn = number of LF contacts Type Gauge S 24-28 C 22 A= { } (nnnx2) -2 3 if yy and zz ≠ 0 : B= {( )} (yy)+(zz) -2 x 2,5+14,5+A 2 if yy or zz = 0 : {( )} B = (yy)or(zz) -1 x 2,5+11,75+A 2 B max. = 87 C=B+6 CRIMP FOR HP/HF CONTACTS ONLY Part numbering : Number of HF or HP contacts 342 E 00 0 - 00 z z - See Fixing on pages 69 to 74 “Mxx” without fixing HF or HP P/N refer to page 95 ( ) A = (zzx2,5) -2,5 2 B = A + 10 C=B+6 Refer to dimension table on cover page 68 Special contacts min. : 04 max. : 64 Fixing hardware for CMM SERIES 320/340 Male : 10 to 49 Female : 50 to 99 P X X X X Letter coding : idem for male and female Number coding : idem for male and female Example : P10A1 mounting with P50A1 Letter code : A to F Number code : 1 to 6 69 Fixing hardware for CMM 320/340 RACK INTERCONNECTION 90° Straight 0,8 min. 2 max. 1,5 min. 4 max. 4 max. Straight No fixing on PCB 90° SERIE PCB Contacts FEMALE CONNECTORS 320 & 340 0,8 min. 2 max. M38 M38H 1,5 min. 4 max. M36 M36H M35 M35H M39 M39H RACK Contacts on cable Straight 90° 90° 0,8 min. 2 max. 1,5 min. 4 max. 0,8 min. 1,5 min. 2 max. 4 max. 4 max. F58 F58H F59 F59H F48 OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK A H11 M35 M39 4 max. F48 H11 No fixing on PCB Fixing Contacts on cable 320 & 340 RACK PCB thickness (mm) CMM SERIES PCB Contacts Straight Floating MALE CONNECTORS Type of contact in connector Type of PCB mount M3xx F40 OK OK OK OK A OK OK OK OK OK H11 F48 OK OK OK OK A OK OK A OK F40 OK OK OK OK OK OK OK OK OK 0,8 min. 2 max. M35 OK OK OK OK OK OK OK 1,5 min. 4 max. M39 OK OK OK OK OK OK OK OK OK OK OK A 4 max. H11 F48 OK OK Floating M3xx No fixing on PCB F40 OK OK OK OK OK A A OK OK OK OK OK OK OK OK A OK OK OK OK OK OK A OK OK OK Card extension Recommended Torque : 0,2 N/m REFERENCE ASSEMBLY ON PCB Straight on PCB F40 OVERALL DIMENSIONS RECOMMENDATION F40 : CMM female : Y-YL-S-C-E (D : straight) CMM male : S-C-E 90° on PCB 4 max. F48 F48 : CMM female : V-VL-S-C-E (D : 90°) CMM male : V-VL-R-S-C-E (D : 90°) Straight on PCB 0,8 min / 2 max F58 : CMM male : Y (D : straight) F58 F58H : CMM male : Y (D : straight) F58H Straight on PCB 1,5 min / 4 max F59 F59H F59 : CMM male : YL (D : straight) F59H : CMM male : YL (D : straight) Make it a habit! Use easy & automatic configurators for CMM micro-connectors single part and mating-half construction on www.nicomatic.com. 70 Fixing hardware for CMM 320/340 RACK INTERCONNECTION HEXAGONAL REFERENCE STANDARD NUT ASSEMBLY ON PCB Straight on PCB 0,8 min / 2 max M35 NUT OVERALL DIMENSIONS RECOMMENDATION M35 : CMM female : Y-S-C (D-E : straight) CMM male : S-C (E : straight) M35H : CMM female : Y (D : straight) M35H Straight on PCB 1,5 min / 4 max M39 M39 : CMM female : YL-S-C (D-E : straight) CMM male : S-C (E : straight) M39H : CMM female : YL (D : straight) M39H Straight on PCB 0,8 min / 2 max M38 : CMM male : Y (D : straight) M38 M38H : CMM male : Y (D : straight) M38H Straight on PCB 1,5 min / 4 max M36 : CMM male : YL (D : straight) M36 M36H : CMM male : YL (D : straight) M36H M3xx xx = (PCB Straight on PCB with floating option thickness + 0,2 mm) x 10 Example : for 3 mm PCB, the reference is M332 (3 + 0,2) x 10 = 32 xx = 32 CMM male : S-C (E : straight) 90° on PCB 4 max. H11 M3xx : CMM female : S-C (E : straight) H11 : CMM female : V-VL-S-C-E (D : 90°) CMM male : V-VL-R-S-C-E (D : 90°) 71 Fixing hardware for CMM 320/340 LOCKED INTERCONNECTION MALE CONNECTORS 4 max. 1min. 2 min. 3 min. 2 max. 3 max. 4 max. 90° LOCKING Straight 0,8 1,5 min. min. 4 max. 2max. 4max. F52 F45 F46 F51 1min. 2min. 3min. 2max. 3max. 4max. H08 H08M H08L F50 H01 H01C OK OK OK OK A OK OK OK OK A OK OK OK OK A OK OK OK OK OK OK OK OK OK OK H08 H08M H08L F4xx H01 H01C F41 F57 M45 OK OK OK OK A OK OK OK OK A OK OK OK OK A OK OK OK OK OK OK OK OK OK OK OK OK OK OK B A A A OK OK A A A OK OK B OK OK OK OK A A OK OK A A OK OK B 2 min. H08M OK 3 max. OK OK OK A A OK OK A A OK OK B No fixing on PCB 0,8 min. 2 max. H08 OK OK OK OK A A OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK A A OK OK B OK OK OK OK OK OK OK OK OK OK OK OK OK OK F41 OK OK OK OK OK OK OK OK OK OK OK F52 OK OK OK OK OK OK OK OK OK OK OK 1,5 min. 4 max. F45 OK OK OK OK OK OK OK OK OK OK OK 4 max. F46 F51 A A A A A A OK OK OK OK A A A A A A OK OK OK OK B B 1 min. 2 max. H08 90° Contacts on cable FEMALE CONNECTORS 0,8 min. F52 2 max. F52H 1,5 min. F45 4 max. F45H F46 4 max. F51 3 min. H08L 4 max. H01 No fixing on PCB H01C CMM SERIES 320 & 340 WITH PCB Contacts Straight Fixing F42 F42H F44 F44H F46 F51 1 min. 2 max. Contacts on cable 90° Straight No fixing on PCB With cover With cover 1,5 min. 4 max. LOCKING No fixing on PCB 0,8 min. 2 max. 320 & 340 WITH Floating fixing Straight CMM SERIES No fixing on PCB PCB thickness (mm) PCB Contacts 90° Card edge with 301500-12 HF Type of contact in connector Type of PCB mount OK OK OK OK A A OK OK A A OK OK B 2 min. 3 max. H08M OK OK OK OK A A OK OK A A OK OK B 3 min. 4 max. H08L OK OK OK OK A A OK OK A A OK OK B OK OK OK OK OK OK OK OK OK OK OK OK Floating fixing F4xx No fixing on PCB No fixing on PCB H01 H01C F41 OK OK OK With cover F57 B B B With cover M45 OK OK OK OK OK B B OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK B B OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK B B B OK OK OK OK OK Make it a habit! Use easy & automatic configurators for CMM micro-connectors single part and mating-half construction on www.nicomatic.com. CMM 320/340 MALE AND FEMALE THREADED FIXING HARDWARE REFERENCE ASSEMBLY ON PCB Straight on PCB H01 72 DIMENSIONS RECOMMENDATION H01/H01C : CMM female : Y-YL-S-C-E (D : straight) CMM male : Y-YL-S-C-E (D : straight) H01C H08 PCB : 1 min. / 2 max. H08M PCB : 2 min. / 3 max. H08L PCB : 3 min. / 4 max. OVERALL 90° on PCB H08/H08M/H08L : CMM female : V-VL-S-C-E (D : 90°) CMM male : V-VL-R-S-C-E (D : 90°) Fixing hardware for CMM 320/340 LOCKED INTERCONNECTION HEXAGONAL STANDARD NUT NUT Recommended Torque : 0,2 N/m REFERENCE F4XX ASSEMBLY ON PCB OVERALL DIMENSIONS RECOMMENDATION Straight on PCB floating option F4XX : CMM female : S-C (E : straight) xx = (PCB thickness + 0,2 mm) x 10 Example : for 3 mm PCB, the reference is F432 (3 + 0,2) x 10 = 32 xx = 32 CMM male : S-C (E : straight) Straight on PCB F41 : CMM female : Y-YL-S-C-E (D : straight) F41 CMM male : S-C-E Straight on PCB 0,8 min / 2 max F52 F52 : CMM female : Y-S-C (D-E : straight) CMM male : S-C (E : straight) F52H : CMM female : Y (D : straight) F52H Straight on PCB 1,5 min / 4 max F45 F45 : CMM female : YL-S-C (D-E : straight) CMM male : S-C (E : straight) F45H : CMM female : YL (D : straight) F45H Straight on PCB 0,8 min / 2 max F42 : CMM male : Y (D : straight) F42 F42H : CMM male : Y (D : straight) F42H Straight on PCB 1,5 min / 4 max F44 F44H F44 : CMM male : YL (D : straight) F44H : CMM male : YL (D : straight) 73 Fixing for CMM 320/340 CMM 320/340 MALE AND FEMALE TAPPED FIXING HARDWARE REFERENCE ASSEMBLY ON PCB OVERALL DIMENSIONS RECOMMENDATION 90° on PCB 4 max. F46 : CMM female : V-VL-S-C-E (D : 90°) F46 CMM male : V-VL-R-S-C-E (D : 90°) 90° on PCB 4 max. F51 : CMM female : V-VL-S-C-E (D : 90°) F51 CMM male : V-VL-R-S-C-E (D : 90°) 90° on PCB 4 max. F50 : Card edge LF contact or mixed F50 Cover option only Male and female S-C (E : straight) F57 Cover option only Male and female S-C (E : straight) M45 74 HF : High Frequency contacts series 30 HP : High Power contacts series 30 FOR CMM 220 AND 320 INSERTION HF female contact insertion HF male contact insertion PART NUMBERING FOR PCB HF & HP SPECIAL CONTACTS These two digits are linked to the connector. Do not use them inside a CMM part number when loaded. All dash signs also disappear Termination length “CMM” = 3mm “45” = 4.5mm “12” = 3mm (Female CMM320) “14” = 4.5mm (Female CMM320) “…” Contact type : 3 = straight 4 = right angle 5 = SMT 90° 6 = SMT straight 30 - 00 - Coaxmatic 30™ 1 = male coax 2 = female coax 3 = high power male 4 = high power female PART NUMBERING FOR HF & HP SPECIAL CONTACTS ON-CABLE For HF contacts only Shield Z = solder S = crimp For HF contacts only Inner contact Z = solder S = crimp These two digits are linked to the connector. Do not use them inside a CMM part number when loaded. All dash signs also disappear Contact type : 3 = straight 4 = right angle - - 75 - { 30 - Use these 2 digits only with 1.2mm dia. cables mounted on a HF straight contact Crimp shield type: 01 = refer to page 81 02 = refer to page 81 Special contacts : 1 = male HF 2 = female HF 3 = male HP 4 = female HP Double shield DS Use these 2 digits only with 75 Ohm cables Contact termination: 10 = for HP 10A 15 = for HP 15A 20 = for HP 20A 12 = for HF cable 1.2mm 20 = for HF cable 2mm 24 = for HF cable 2.4mm 26 = for HF cable 2.6mm 47 = for HF cable type UT47 85 = for HF cable type UT85 “...” 75 HF : High Frequency contact series 30 MALE STRAIGHT ON PCB P/N 30-1300-xx Loaded Length L 1300CMM 3 mm 130045 4,5 mm FEMALE STRAIGHT ON PCB P/N 30-2300-xx Loaded Length L Loaded 2300CMM 3 mm 230012 Length L 3 mm 230045 4,5 mm 230014 4,5 mm PCB LAYOUT 30-1300-xx & 30-2300-xx A = nn - 2 B = {(yy + zz) x 4 } + A + 7 B max. = 65 mm A= [ B =A + 9 B max. = 87 76 ] {(yy + zz) x 4 + nn} x 2 - 2 3 HF : High Frequency contact series 30 MALE 90° PCB P/N 30-1400-xx Loaded Length L 1400CMM 3 mm 140045 4,5 mm Loaded Length L PCB LAYOUT 30-1400-xx FEMALE 90° PCB P/N 30-2400-xx 2400CMM 3 mm 240045 4,5 mm PCB LAYOUT 30-2400-xx A = nn - 2 B = {(yy + zz) x 4 } + A + 7 B max. = 65 mm A= [ ] {(yy + zz) x 4 + nn} x 2 - 2 3 B =A + 9 B max. = 87 77 HF : High Frequency contact series 30 MALE 90° SMT FOR CMM 220 SERIES (WITHOUT CONTACTS) P/N 30-1500-CMM PCB LAYOUT 30-1500-CMM A = (nn x 4) - 4 B =A + 9 C=B+5 PART NUMBERING Number of contacts 2 2 1 D 0 0 F27 78 00 z z 1 5 0 0 CMM HF : High Frequency contact series 30 MALE 90° SMT FOR CMM 220 SERIES P/N 30-1500-12 PCB LAYOUT 30-1500-12 A = nn - 2 B = {(yy + zz) x 4 } + A + 7 B max. = 65 mm C=B+5 PART NUMBERING Number of contacts opposite side LF pin 1 Number of contacts LF pin 1 side 2 2 1 BR n n F34 y y z z 15001 2 Number of LF contacts 79 HF : High Frequency contact series 30 MALE 90° SMT FOR CMM 320 SERIES P/N 30-1500-12 PCB LAYOUT 30-1500-CMM A= [ B =A + 9 B max. = 87 C = A + 15 PART NUMBERING Number of contacts opposite side LF pin 1 Number of contacts LF pin 1 side 3 2 1 BR n n n F50 Number of LF contacts 80 y y z z 15001 2 ] {(yy + zz) x 4 + nn} x 2 - 2 3 HF : High Frequency contact series 30 MALE STRAIGHT SMT FOR CMM 220 SERIES P/N 30-1600 FEMALE STRAIGHT SMT FOR CMM 220 SERIES P/N 30-2600 PCB LAYOUT 30-1600 & 30-2600 81 HF : High Frequency contact series 30 MALE STRAIGHT CRIMP ON CABLES Ø 1.2 P/N 30-1312-ZS Cable assy instruction IC30HF01 on page 118 Loaded Unloaded ØB ØC 1312ZS01 30-1312-ZS-01 1 mm 1,25 mm For cable type NEXANS 50VMTX 1312ZS02 30-1312-ZS-02 0,85 mm 1,15 mm For cable type AXON SM50 FEMALE STRAIGHT CRIMP ON CABLES Ø 1.2 P/N 30-2312-ZS Cable assy instruction IC30HF01 on page 118 Loaded 82 Unloaded ØB ØC 2312ZS01 30-2312-ZS-01 1 mm 1,25 mm For cable type NEXANS 50VMTX 2312ZS02 30-2312-ZS-02 0,85 mm 1,15 mm For cable type AXON SM50 HF : High Frequency contact series 30 MALE STRAIGHT CRIMP ON CABLE P/N 30-13xx-SS & 30-13xx-ZS Cable assy instruction IC30HF02 on page 119 Loaded Unloaded Cable A ØB ØC ØD Hex. E 1320SS 30-1320-SS Ø 2,0 1 mm 2,2 mm 0,5 mm 2,4 on flat 1324SS 30-1324-SS Ø 2,4 1,5 mm 2,8 mm 0,6 mm 2,8 on flat 1326SS 30-1326-SS Ø 2,7 1,7 mm 2,8 mm 0,6 mm 2,8 on flat FEMALE STRAIGHT CRIMP ON CABLE P/N 30-23xx-SS & 30-23xx-ZS Cable assy instruction IC30HF02 on page 119 Loaded Unloaded Cable A ØB ØC ØD Hex. E 2320SS 30-2320-SS Ø 2,0 1 mm 2,2 mm 0,5 mm 2,4 on flat 2324SS 30-2324-SS Ø 2,4 1,5 mm 2,8 mm 0,6 mm 2,8 on flat 2326SS 30-2326-SS Ø 2,7 1,7 mm 2,8 mm 0,6 mm 2,8 on flat 83 HF : High Frequency contact series 30 MALE 90° CRIMP ON CABLE P/N 30-14xx-ZS Cable assy instruction IC30HF03 on page 120 Loaded Unloaded Cable A ØB ØC Hex. E 1412ZS 30-1412-ZS Ø 1,2 0,7 mm 1,3 mm 1,9 on flat 1420ZS 30-1420-ZS Ø 2,0 1 mm 2,2 mm 2,4 on flat 1424ZS 30-1424-ZS Ø 2,4 1,5 mm 2,8 mm 2,8 on flat 1426ZS 30-1426-ZS Ø 2,7 1,7 mm 2,8 mm 2,8 on flat FEMALE 90° CRIMP ON CABLE P/N 30-24xx-ZS Cable assy instruction IC30HF03 on page 120 84 Loaded Unloaded Cable A ØB ØC Hex. E 2412ZS 30-2412-ZS Ø 1,2 0,7 mm 1,3 mm 1,9 on flat 2420ZS 30-2420-ZS Ø 2,0 1 mm 2,2 mm 2,4 on flat 2424ZS 30-2424-ZS Ø 2,4 1,5 mm 2,8 mm 2,8 on flat 2426ZS 30-2426-ZS Ø 2,7 1,7 mm 2,8 mm 2,8 on flat HF : High Frequency contact series 30 MALE STRAIGHT ON CABLE SEMI-RIGID P/N 30-13xx-ZZ Loaded Unloaded Cable A ØB ØC ØD 1347ZZ 30-1347-ZZ UT 47 1,4 mm 1 mm 0,5 mm 1385ZZ 30-1385-ZZ UT 85 2,3 mm 1,7 mm 0,6 mm FEMALE STRAIGHT ON CABLE SEMI-RIGID P/N 30-23xx-ZZ Loaded Unloaded Cable A ØB ØC ØD 2347ZZ 30-2347-ZZ UT 47 1,4 mm 1 mm 0,5 mm 2385ZZ 30-2385-ZZ UT 85 2,3 mm 1,7 mm 0,6 mm 85 HF : High Frequency contact series 30 MALE 90° ON CABLE SEMI-RIGID P/N 30-14xx-ZZ Loaded Unloaded Cable A ØB ØC 1447ZZ 30-1447-ZZ UT 47 1,4 mm 1 mm 1485ZZ 30-1485-ZZ UT 85 2,3 mm 1,7 mm FEMALE 90° ON CABLE SEMI-RIGID P/N 30-24xx-ZZ 86 Loaded Unloaded Cable A ØB ØC 2447ZZ 30-2447-ZZ UT 47 1,4 mm 1 mm 2485ZZ 30-2485-ZZ UT 85 2,3 mm 1,7 mm HP : High Power contact series 30 MALE STRAIGHT ON PCB P/N 30-3300-XX Loaded Length L 3300CMM 3 mm 330045 4,5 mm FEMALE STRAIGHT ON PCB P/N 30-4300-XX Loaded Length L Loaded 4300CMM 3 mm 430012 Length L 3 mm 430045 4,5 mm 430014 4,5 mm PCB LAYOUT 30-3300-XX & 30-4300-XX A = nn - 2 B = {(yy + zz) x 4 } + A + 7 B max. = 65 mm A= [ ] {(yy + zz) x 4 + nn} x 2 - 2 3 B =A + 9 B max. = 87 87 HP : High Power contact series 30 MALE 90° PCB P/N 30-3400-XX Loaded Length L 3400CMM 3 mm 340045 4,5 mm Loaded Length L PCB LAYOUT 30-3400-XX FEMALE 90° PCB P/N 30-4400-XX 4400CMM 3 mm 440045 4,5 mm PCB LAYOUT 30-4400-XX A = nn - 2 B = {(yy + zz) x 4 } + A + 7 B max. = 65 mm A= [ B =A + 9 B max. = 87 88 ] {(yy + zz) x 4 + nn} x 2 - 2 3 HP : High Power contact series 30 MALE 90° SMT 30-3500 PCB LAYOUT 30-3500 FEMALE 90° SMT 30-4500 PCB LAYOUT 30-4500 89 HP : High Power contact series 30 MALE STRAIGHT SMT P/N 30-3600 PCB LAYOUT 30-3600 FEMALE STRAIGHT SMT P/N 30-4600 PCB LAYOUT 30-4600 90 HP : High Power contact series 30 MALE 90° SMT CARD EDGE (WITHOUT LF CONTACTS) 30-3500-CMM PCB LAYOUT 30-3500-CMM A = (nn x 4) - 4 B =A + 9 C=B+5 PART NUMBERING Number of contacts 2 2 1 D 0 0 F27 00 z z 3 5 0 0 CMM 91 HP : High Power contact series 30 MALE 90° SMT CARD EDGE 30-3500-12 (FOR CMM 220 SERIES) PCB LAYOUT 30-3500-12 A = nn - 2 B = {(yy + zz) x 4 } + A + 7 B max. = 65 mm C=B+5 PART NUMBERING Number of contacts opposite side LF pin 1 Number of contacts LF pin 1 side 2 2 1 BR n n F34 Number of LF contacts 92 y y z z 35001 2 HP : High Power contact series 30 MALE 90° SMT CARD EDGE 30-3500-12 (FOR CMM 320 SERIES) PCB LAYOUT 30-3500-12 A= [ ] {(yy + zz) x 4 + nn} x 2 - 2 3 B =A + 9 B max. = 87 C = A + 15 PART NUMBERING Number of contacts opposite side LF pin 1 Number of contacts LF pin 1 side 3 2 1 BR n n n F50 y y z z 35001 2 Number of LF contacts 93 HP : High Power contact series 30 MALE STRAIGHT ON CABLE P/N 30-33xx (solder or crimp) Cable assy instruction IC30HP02 on page 122 Loaded Unloaded Ampere 3305 30-3305 5A 3308 30-3308 8A 3310 30-3310 10A 3315 30-3315 15A 3320 30-3320 20A Cable A AWG 20 AWG 18 AWG 16 AWG 14 AWG 12 X X X X X X X ØB ØC Length D Length E Length F Solder Crimp by HX3 Crimp by hole body conductor Hexagone size/Dies AF8 1,1 mm 1,65 mm 6,2 mm 6,7 mm 4,5 mm OK Hex. 1,9 mm/C14923 OK 1,35 mm 1,85 mm 6,2 mm 6,7 mm 4,5 mm OK Hex. 1,9 mm/C14923 OK 1,7 mm 6,2 mm 6 mm 6 mm OK OK 2 mm 6,2 mm 6 mm 6 mm OK OK 2,6 mm 5,5 mm 6 mm 5,3 mm OK OK FEMALE STRAIGHT ON CABLE P/N 30-43xx (solder or crimp) Cable assy instruction IC30HP02 on page 122 Loaded Unloaded Ampere 94 4305 30-4305 5A 4308 30-4308 8A 4310 30-4310 10A 4315 30-4315 15A 4320 30-4320 20A Cable A AWG 20 AWG 18 AWG 16 AWG 14 AWG 12 X X X X X X X ØB ØC Length D Length E Length F Solder Crimp by HX3 Crimp by hole body conductor Hexagone size/Dies AF8 1,1 mm 1,65 mm 6,2 mm 6,7 mm 4,5 mm OK Hex. 1,9 mm/C14923 1,35 mm 1,85 mm 6,2 mm 6,7 mm 4,5 mm OK Hex. 1,9 mm/C14923 OK 1,7 mm 6,2 mm 6 mm 6 mm OK OK 2 mm 6,2 mm 6 mm 6 mm OK OK 2,6 mm 5,5 mm 6 mm 5,3 mm OK OK OK HF : High Frequency contacts series 22 HP : High Power contacts series 22 FOR CMM 340 INSERTION HF female contact insertion The special contact gender is determined by the body and not by the central contact HF male contact insertion PART NUMBERING FOR PCB HF & HP SPECIAL CONTACTS These two digits are linked to the connector. Do not use them inside a CMM part number when loaded. All dash signs also disappear Termination length “12” = 1st row 3mm “22” = 2nd row 3mm “14” = 1st row 4.5mm “24” = 2nd row 4.5mm “…” Contact type: 3 = straight 4 = right angle 5 = SMT 90° 6 = SMT straight 22 - 00 - Coaxmatic 22™ 1 = male coax 2 = female coax 3 = high power male 4 = high power female PART NUMBERING FOR HF & HP SPECIAL CONTACTS ON-CABLE For HF contacts only shield Z = solder S = crimp For HF contacts only Inner contact Z = solder S = crimp These two digits are linked to the connector. Do not use them inside a CMM part number when loaded. All dash signs also disappear Use these 2 digits only with 1.2mm dia. cables mounted on a HF straight contact Crimp shield type: 01 = refer to page 92 02 = refer to page 92 Contact type: 3 = straight “...” 22 Special contacts : 1 = male HF 2 = female HF 3 = male HP 4 = female HP 3 - Z - 75 Use these 2 digits only with 75 Ohm cables Contact termination: 10 = for HP 10A 12 = for HF cable 1.2mm 20 = for HF cable 2mm 95 HF : High Frequency contacts series 22 MALE STRAIGHT ON PCB P/N 22-1300-xx Loaded Length L 130012 3 mm 130014 4,5 mm FEMALE STRAIGHT ON PCB P/N 22-2300-xx Loaded Length L 230012 3 mm 230014 4,5 mm PCB LAYOUT 22-1300-xx & 22-2300-xx A= { (nnx2) 3 } -2 if yy and zz ≠ 0 : B= {( )} (yy)+(zz) -2 x 2,5+14,5+A 2 if yy or zz = 0 : {( )} B = (yy)or(zz) -1 x 2,5+11,75+A 2 B max. = 87 96 HF : High Frequency contacts series 22 MALE 90° PCB P/N 22-1400-xx Loaded First row 140012 Second row 140022 First row 140014 Second row 140024 Loaded Length L it mounted in same connector 140002 3 mm it mounted in same connector 140004 4,5 mm Loaded Length L it mounted in same connector 240002 3 mm it mounted in same connector 240004 4,5 mm PCB LAYOUT 22-1400-xx A= { (nnx2) 3 } -2 if yy or zz ≠ 0 : B= {( )} (yy)+(zz) -2 x 2,5+14,5+A 2 if yy or zz = 0 : {( )} B = (yy)or(zz) -1 x 2,5+11,75+A 2 B max. = 87 FEMALE 90° PCB P/N 22-2400-xx Loaded First row 240012 Second row 240022 First row 240014 Second row 240024 PCB LAYOUT 22-2400-xx A= { (nnx2) 3 } -2 if yy and zz ≠ 0 : B= {( )} (yy)+(zz) -2 x 2,5+14,5+A 2 if yy or zz = 0 : {( )} B = (yy)or(zz) -1 x 2,5+11,75+A 2 B max. = 87 97 HF : High Frequency contacts series 22 MALE STRAIGHT TO CRIMP ON CABLE Ø 1.2 P/N 22-1312-ZS-xx Cable assy instruction IC22HF01 on page 116 Loaded Unloaded ØB ØC 1312ZS01 22-1312-ZS-01 1 mm 1,25 mm For cable type NEXANS 50VMTX 1312ZS02 22-1312-ZS-02 0,85 mm 1,15 mm For cable type AXON SM50 FEMALE STRAIGHT TO CRIMP ON CABLE Ø 1.2 P/N 22-2312-ZS-xx Cable assy instruction IC22HF02 on page 117 Loaded 98 Unloaded ØB ØC 2312ZS01 22-2312-ZS-01 1 mm 1,25 mm For cable type NEXANS 50VMTX 2312ZS02 22-2312-ZS-02 0,85 mm 1,15 mm For cable type AXON SM50 HF : High Frequency contacts series 22 MALE STRAIGHT ON CABLE P/N 22-1320-ZZ Loaded Unloaded 1320ZZ 22-1320-ZZ Loaded Unloaded 2320ZZ 22-2320-ZZ FEMALE STRAIGHT ON CABLE P/N 22-2320-ZZ 99 HP : High power contacts series 22 MALE STRAIGHT ON PCB P/N 22-3300-xx Loaded Length L 330012 3 mm 330014 4,5 mm FEMALE STRAIGHT ON PCB P/N 22-4300-xx Loaded Length L 430012 3 mm 430014 4,5 mm PCB LAYOUT 22-3300-xx & 22-4300-xx A= { (nnx2) 3 } -2 if yy and zz ≠ 0 : B= {( )} (yy)+(zz) -2 x 2,5+14,5+A 2 if yy or zz = 0 : {( )} B = (yy)or(zz) -1 x 2,5+11,75+A 2 B max. = 87 100 HP : High power contacts series 22 MALE 90° PCB P/N 22-3400-xx Loaded First row 340012 Second row 340022 First row 340014 Second row 340024 Loaded Length L it mounted in same connector 340002 3 mm it mounted in same connector 340004 4,5 mm FEMALE 90° PCB P/N 22-4400-xx Loaded First row 440012 Second row 440022 First row 440014 Second row 440024 Loaded Length L it mounted in same connector 440002 3 mm it mounted in same connector 440004 4,5 mm PCB LAYOUT 22-3400-xx & 22-4400-xx A= { (nnx2) 3 } -2 if yy and zz ≠ 0 : B= {( )} (yy)+(zz) -2 x 2,5+14,5+A 2 if yy or zz = 0 : {( )} B = (yy)or(zz) -1 x 2,5+11,75+A 2 B max. = 87 101 HP : High power contacts series 22 MALE STRAIGHT ON CABLE P/N 22-33XX (solder & crimp) Cable assy instruction IC22HP02 on page 121 Loaded Unloaded Ampere AWG 20 3305 22-3305 5A 3308 22-3308 8A 3310 22-3310 10A Cable A AWG 18 X X X X ØB ØC Length D hole 1,1 mm 1,65 mm 6,2 mm 8,8 mm 4,5 mm OK Hex. 1,9 mm/C14923 1,35 mm 1,85 mm 6,2 mm 8,8 mm 4,5 mm OK Hex. 1,9 mm/C14923 OK 6,2 mm 8,8 mm 6 mm OK Hex. 1,9 mm/C14923* OK AWG 16 X 1,7 mm Length E Length F body conductor Solder Crimpby HX3 Crimp by Hexagone size/Dies AF8 OK * only for AWG 16 FEMALE STRAIGHT ON CABLE P/N 22-43XX (solder & crimp) Cable assy instruction IC22HP02 on page 121 Loaded Unloaded Ampere AWG 20 4305 22-4305 5A 4308 22-4308 8A 4310 22-4310 10A * only for AWG 16 102 Cable A AWG 18 X X X X ØB ØC Length D hole 1,1 mm 1,65 mm 6,2 mm 7,7 mm 4,5 mm OK Hex. 1,9 mm/C14923 OK 1,35 mm 1,85 mm 6,2 mm 7,7 mm 4,5 mm OK Hex. 1,9 mm/C14923 OK 6,2 mm 7,7 mm 6 mm OK Hex. 1,9 mm/C14923* OK AWG 16 X 1,7 mm Length E Length F body conductor Solder Crimpby HX3 Crimp by Hexagone size/Dies AF8 Tools DANIELS MH800 TOOL AND POSITIONER P/N K1131 & K1692 Tools reference Barrel DANIELS MH800 only MH800 Positioner K1692 only C12929 Positioner K1131 only K1131 DANIELS MH800 & K1131 C12237 DANIELS MH800 & K1692 C14925 Crimp barrel accomodation for LF contacts Hand crimp tool reference Positioner Contacts type Contacts reference Wire size (AWG) Crimp tool setting DANIELS MH800 K1692 Male C 12960 22 6 DANIELS MH800 K1692 Male S 12969 24 7 DANIELS MH800 K1692 Male S 12969 26 & 28 6 DANIELS MH800 K1692 Female C C13064-P 22 6 DANIELS MH800 K1692 Female S C12468 24 7 DANIELS MH800 K1692 Female S C12468 26 & 28 6 Crimp barrel accomodation for central contact HF30 series Hand crimp tool reference Positioner Conductor DANIELS MH800 K1131 Ø 0,30 Crimp tool setting 2&3 DANIELS MH800 K1131 Ø 0,50 3&4 DANIELS AF8 TOOL P/N 16459 Tools reference Reference Nicomatic DANIELS AF8 only 16459 DANIELS AF8 + C16460 C16462 DANIELS AF8 + C16461 C16463 Crimp barrel accomodation for crimping HP contact Hand crimp tool reference Positioner HP contact serie DANIELS AF8 C16460 30 DANIELS AF8 C16461 22 103 Tools DANIELS HX3 TOOL P/N 13858 Tools reference Reference Nicomatic DANIELS HX3 only 13858 DANIELS HX3 & C13847 C12238 DANIELS HX3 & C14680 C14770 Crimp barrel accomodation for crimping coaxial contact shield Hand crimp tool reference Dies Hexagonal imprint DANIELS HX3 C13847 Hex. 1,9 / Hex. 2,4 / Hex. 2,8 DANIELS HX3 C14680 Hex. 3,25 / Hex. 4 CRIMP DIE C13847 FOR DANIELS HX3 TOOL (HF CONTACT) CRIMP DIE C14680 FOR DANIELS HX3 TOOL (HF CONTACT) 104 Tools LF CONTACTS INSERTION & WITHDRAWAL TOOL P/N C12935 Rep Reference Assembly C12935 1 13241 Body 2 13240 Plug 3 13170 Female contact extraction tip 4 13242 Male contact extraction tip 5 13171 24-28 AWG insertion tip 6 13712 22 AWG insertion tip HF / HP SERIES 22 CONTACTS REMOVAL P/N C13997 Rep Reference Assembly C13997 1 13241 Body 2 13240 Plug 3 13995 Female contact extraction tip 4 13996 Male contact extraction tip 5 16139 Male & female contact insertion tool HF / HP SERIES 30 CONTACTS REMOVAL P/N 12368 105 Tools LATCH SEPARATION TOOL P/N C14790 Series A max. A min. A max. LF contacts A min. LF contacts CMM 100 53 25 7 2 CMM 200 53 50 7 4 SCREWDRIVER P/N C14743 FOR NUT P/N 12685 Optional: dynamometric screwdriver specifically designed for low torques (includes bits & adjusting key). MOUNTING OF C14772 BACK CAPS Hex. 5mm Tool not delivered 106 SUCOFLEX SOLDER TOOL P/N C14777 Accessories STRAIGHT COVER FOR CMM SERIES 220 (male & female) P/N CMM-C2-XX (other upon request) Material : high temp. thermoplastic (-55°C to +200°C) Length B in mm (distance between fixing hardware axies) CMM C2 CMM 220 series CMM-C2-11 CMM-C2-15 CMM-C2-17 CMM-C2-25 CMM-C2-27 CMM-C2-31 CMM-C2-39 CMM-C2-45 CMM-C2-47 CMM-C2-49 CMM-C2-53 CMM-C2-55 Length B 11 15 17 25 27 31 39 45 47 49 53 55 Length A mm mm mm mm mm mm mm mm mm mm mm mm 23,7 23,7 17,2 26,7 26,7 29,7 29,7 33,7 33,7 33,7 33,7 33,7 Screw (x2) mm mm mm mm mm mm mm mm mm mm mm mm inc lud ed Reference Note: F28 and M18 fixings are not included with the cover 45° COVER FOR CMM SERIES 220 (male & female) P/N CMM-C2-XX-45 (upon request) Material : high temp. thermoplastic (-55°C to +200°C) Length B in mm (distance between fixing hardware axies) CMM C2 4 5 CMM 220 series 45 for exit 45° Reference Length B Length A Screw (x2) CMM-C2-17-45 17 mm 24,4 mm Included CMM220 male F28 fixing not included with cover CMM220 female M18 fixing not included with cover 90° COVER FOR CMM SERIES 220 (male & female) P/N CMM-C2-XX-90 (upon request) Material : high temp. thermoplastic (-55°C to +200°C) Length B in mm (distance between fixing hardware axies) CMM C2 9 0 CMM 220 series 90 for exit 90° Reference Length B Length A Screw (x2) CMM-C2-53-90 53 mm 26 mm Included CMM220 male F28 fixing not included with cover CMM220 female M18 fixing not included with cover Note: Aluminum covers are available upon request. Contact us. 107 Accessories COVERS STRAIGHT FOR CMM SERIES 320 & 340 (male & female) P/N CMM-C3-XX.X Material : high temp. thermoplastic (-55°C to +200°C) Length B in mm (distance between fixing hardware axies) CMM C3 . CMM series 320 & 340 Reference Length B Length A Screw (x2) CMM-C3-27.5 CMM-C3-45.0 27,5 mm 45,0 mm 34,4 mm 34,4 mm Included For CMM320/340 male & female M45 or F57 fixing not included with cover Other upon request SHIELDING FOR CMM SERIES 220 (male straight on PCB) P/N 12997-XX (upon request) XX = distance between fixing axis B SHIELDING FOR CMM SERIES 220 (male 90° on PCB) P/N 12998-XX (upon request) XX = distance between fixing axis B SHIELDING FOR CMM SERIES 220 (female on cable) P/N C13024-XX (upon request) XX = distance between fixing axis B 108 Accessories BACKPOTTING SHAPE FOR CMM SERIES 200 (female) P/N 14501-XX Material : thermoplastic 100°C max. Reference Length B 14501-07 14501-09 14501-11 14501-13 14501-15 14501-17 14501-19 14501-21 14501-23 14501-25 14501-27 14501-29 14501-31 14501-33 14501-35 14501-37 14501-39 14501-41 14501-43 14501-45 14501-47 14501-49 14501-51 14501-53 min. 7 mm 9 mm 11 mm 13 mm 15 mm 17 mm 19 mm 21 mm 23 mm 25 mm 27 mm 29 mm 31 mm 33 mm 35 mm 37 mm 39 mm 41 mm 43 mm 45 mm 47 mm 49 mm 51 mm max. 53 mm BACKPOTTING SHAPE FOR CMM SERIES 220 (male & female) P/N 14143-XX Material : thermoplastic 100°C max. Reference Length B 14143-09 14143-11 14143-13 14143-15 14143-17 14143-19 14143-21 14143-23 14143-25 14143-27 14143-29 14143-31 14143-33 14143-35 14143-37 14143-39 14143-41 14143-43 14143-45 14143-47 14143-49 14143-51 14143-53 14143-55 14143-57 14143-59 14143-61 14143-63 14143-65 min. 9 mm 11 mm 13 mm 15 mm 17 mm 19 mm 21 mm 23 mm 25 mm 27 mm 29 mm 31 mm 33 mm 35 mm 37 mm 39 mm 41 mm 43 mm 45 mm 47 mm 49 mm 51 mm 53 mm 55 mm 57 mm 59 mm 61 mm 63 mm max. 65 mm Note: Special housing with integrated backpotting available upon request. 109 Accessories CONTACTS ALIGNMENT PLATE P/N 14601-120 Material : high temperature thermoplastic (-55°C to +200°C) Divisible Note : systematically delivered and mounted on the CMM 320 series "right angle" (V and VL types) SILICON INTERFACIAL SEAL (for male connector except S-C types) LF 220 series P/N 14599-54 = 52 mm max. LF 320 series P/N 14980-120 = 78 mm max. Special contacts 220 series P/N 16053-15 = 60,2 mm max. Mix-layout on request 110 Accessories COAX CABLE CRIMP TERMINATION (straight for cables Ø 2 and Ø 2,7) Cable A ØB ØC Hex. E C14759 C14760 Ø2 1 mm 2,2 mm 2,4 on flat Ø 2,7 1,7 mm 2,8 mm 2,8 on flat COAX CABLE CRIMP TERMINATION (90° for cables Ø 2 and Ø 2,7) Cable A ØB ØC Length D Hex. E C14761 C14762 Ø2 1 mm 2,2 mm 3,4 mm 2,4 on flat Ø 2,7 1,7 mm 2,8 mm 3,8 mm 2,8 on flat 111 Accessories COAX CABLE CRIMP TERMINATION P/N C13313 for RG 178 and P/N C14765 for RG 178 DS ØC Hex. E C13313 C14765 RG178 2,2 mm 2,4 mm RG178DS 2,8 mm 2,8 mm COAX CABLE CRIMP TERMINATION P/N C12780 for cables RG 316 CRIMP GAUGE REDUCER for awg 30-32 for LF contacts P/N 12922 & 14142 112 Gender Contact “C” Reducer Tool Positioner Position 1st crimp Male Female 12960 C13064-P 12922 MH800 K1692 Contact + reducer + cable position “4” Male Female 12960 C13064-P 14142 MH800 K1692 Reducer + cable position “8” Position 2nd crimp (Reducer & cable) + contact position “4” Cable instructions (ICLF01) 113 Cable instructions HF Supplier P/N Ø Cable Series CONNECTION CONTACTS Gender Ref. contact Male (30-1312-ZS-02 *) MODE Central contact Shield Impedance Solder Crimped Hex. 1,9 mm 50 Ohm Solder Crimped Hex. 1,9 mm 75 Ohm Crimped Hex. 2,8 mm 50 Ohm Crimped Hex. 2,8 mm 50 Ohm Crimped Hex. 2,8 mm 75 Ohm Crimped Hex. 3,25 mm 50 Ohm Crimped Hex. 3,25 mm 75 Ohm 30-1312-ZS-01 30-1412-ZS HF30 50VMTX (SM 50 *) 30-2312-ZS-01 Female 1,2 mm 30-2412-ZS Male HF22 Female Nexans (Axon *) 75VMTX (SM 75 *) Female 1,2 mm SPECIAL Female Male 2,3 mm HF30 Female Male P 812817 2,3 mm HF30 Female Axon PTFE Cellular Male P 804298 B 2,4 mm HF30 Female Male P0530912 2,7 mm HF30 Female Male P530268 3 mm (30-2312-ZS-75-02 *) 30-2412-ZS-75 HF22 P500955 (30-1312-ZS-75-02 *) 30-2312-ZS-75-01 Male Axon RG 179 DT 22-2312-ZS-01 (22-2312-ZS-02 *) 30-1412-ZS-75 HF30 Axon RG 316 DT 22-1312-ZS-01 (22-1312-ZS-02 *) 30-1312-ZS-75-01 Male Axon RG 178 DT (30-2312-ZS-02 *) HF30 Female 22-1312-ZS-75-01 (22-1312-ZS-75-02 *) 22-2312-ZS-75-01 (22-2312-ZS-75-02 *) 30-1320-DS On choice 30-1420-DS Solder 30-2320-DS On choice 30-2420-DS Solder 30-1324-DS On choice 30-1424-DS Solder 30-2324-DS On choice 30-2424-DS Solder 30-1324-DS-75 On choice 30-1424-DS-75 Solder 30-2324-DS-75 On choice 30-2424-DS-75 Solder 30-1326-DS On choice 30-1426-DS Solder 30-2326-DS On choice 30-2426-DS Solder 30-1326-DS-75 On choice 30-1426-DS-75 Solder 30-2326-DS-75 On choice 30-2426-DS-75 Solder DT = DS (Double Shield) ØB 114 ØC P/N terminal -01 for 50VMTX cable type 1 mm 1,25 mm P/N terminal -02 for SM 50 cable type 0,85 mm 1,15 mm Sleeve Cable instructions NORMES MIL-C-17 HF NF C93-550 Ø Cable Series CONTACTS Gender Ref. contact Central contact 30-1320-SS Crimped Male 30-1320-ZS 30-1420-ZS HF30 RG 178 KX 21 A 2 mm 30-2320-SS Female 30-2320-ZS Male Female 22-1320-ZZ 22-2320-ZZ Male 30-1326-ZS 30-2420-ZS HF22 KX 22 A 2,7 mm 30-1426-ZS HF30 30-2326-SS Female 30-2326-ZS 30-2426-ZS COAX CABLE 30-1326-SS RG 316 30-1326-SS Male RG 174 KX 3 B 2,7 mm 30-1326-ZS 30-1426-ZS HF30 30-2326-SS Female 30-2326-ZS 30-2426-ZS 30-1326-SS-75 Male RG 179 2,7 mm 30-1326-ZS-75 30-1426-ZS-75 HF30 30-2326-SS-75 Female 30-2326-ZS-75 30-2426-ZS-75 HF Supplier P/N Ø Cable Series CONTACTS Gender Male SEMI-RIGID UT47 1,2 mm HF30 Female (Axon *) UT85 (QFX 86 SPCW *) Male 2,2 mm CONNECTION HF30 Female Ref. contact HF Solder Crimped MODE Shield Crimped Hex. 2,4 mm Impedance 50 Ohm Solder Solder Crimped Solder Crimped Crimped Hex. 2,8 mm 50 Ohm Crimped Hex. 2,8 mm 50 Ohm Crimped Hex. 2,8 mm 75 Ohm Solder Crimped Solder Crimped Solder Crimped Solder Crimped Solder CONNECTION MODE Central contact Shield Impedance Solder Solder 50 Ohm Solder Solder 50 Ohm 30-1347-ZZ 30-1447-ZZ 30-2347-ZZ 30-2447-ZZ 30-1385-ZZ 30-1485-ZZ 30-2385-ZZ 30-2485-ZZ 115 Cable instructions (IC22HF01) 116 Cable instructions (IC22HF02) 117 Cable instructions (IC30HF01) 1 - Thread the sleeve until stop onto the cable - Place the shield on the sleeve 2 - Thread the insulator - Solder the inner contact on the conductor 3 - Thread to the body. 4 - CRIMP - Tool : - Die : - Hexagone : - Position : 118 DANIELS HX3 C13847 1,9 mm / flat 9,95 mm ØB ØC P/N terminal -01 1 1,25 P/N terminal -02 0,85 1,15 Sleeve Cable instructions (IC30HF02) Central crimp DANIELS MH800 Cable ØA Body ØB Sleeve ØC Contact ØD 30-x320-SS 2 mm 1 mm 2,2 mm 0,5 mm 30-x320-DS 2,3 mm 1 mm 2,8 mm 0,5 mm 30-x324-SS 2,4 mm 1,5 mm 2,8 mm 0,6 mm 30-x326-SS 2,7 mm 1,7 mm 2,8 mm 0,6 mm 30-x326-DS 3 mm 1,7 mm 3,25 mm 0,6 mm Hexagonal imprint E sleeve crimp DANIELS HX3 tool Positioner K1131 Conductor Ø 0,3 Conductor Ø 0,5 Die C13847 Hex.1,9 Hex.2,4 Die C14680 Hex.2,8 Hex.3,25 Hex.4 x x Position 2 / 3 Position 3 / 4 x x x 1 - Mount the inner contact on the conductor and solder or crimp. (crimping with DANIELS MH800 positioner K1131) 2 - Thread the sleeve onto the cable and bent the shield at 90°. 3 - Push until stop inside the body. 4 - Thread the sleeve until stop on the body so as to bent the shield. 5 - Crimp the sleeve 119 Cable instructions (IC30HF03) 1 - Thread the sleeve on cable and bent the shield at 90° 2 - Place the inner contact until stop in the body. Insert the cable and solder the conductor onto the inner contact 3 - Thread the sleeve until stop on the body so as to bent the shield Hexagonal imprint E sleeve crimp DANIELS HX3 tool 30-x412-ZS Cable ØA Body ØB Sleeve ØC Contact 1,2 mm 0,7 mm 1,3 mm solder Hex.2,4 Die C14680 Hex.2,8 Hex.3,25 x 30-x420-ZS 2 mm 1 mm 2,2 mm solder 30-x420-DS 2,3 mm 1 mm 2,8 mm solder x 30-x424-ZS 2,4 mm 1,5 mm 2,8 mm solder x 30-x426-ZS 2,7 mm 1,7 mm 2,8 mm solder x 30-x426-DS 3 mm 1,7 mm 3,25 mm solder 4 - Crimp the sleeve with DANIELS HX3 tool and mount the back cap with tool P/N C14772 120 Die C13847 Hex.1,9 x x Hex.4 Cable instructions (IC22HP02) 121 Cable instructions (IC30HP02) 122 Index General information CMM presentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .p 2 CMM specifications & dimension tables . . . . . . . . . . . . . . . .p 3-4-5 Contacts information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .p 7-11 Male and Female housings marking . . . . . . . . . . . . .p 12-13 Standard part numbering & product families . . . . . .p 14-15 Custom products & innovations . . . . . . . . . . . . . . . .p 125 CMM 100/200 Series p 17-25 Contact arrangements & configuration . . . . . . . . . . . . . . . . .p 18-19 Male connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .p 20-22 Female connectors . . . . . . . . . . . . . . . . . . . . . . . . . .p 23-25 Retention latches information . . . . . . . . . . . . . . . . .p 22 CMM 220 Series CMM LF introduction page . . . . . . . . . . . . . . . . . . . . . . . . . .p Contact arrangements & configuration . . . . . . . . . . . . . . . . .p Male connectors with LF contacts . . . . . . . . . . . . . . . . . . . . .p Female connectors with LF contacts . . . . . . . . . . . . . . . . . . .p Mixed-Layout introduction page . . . . . . . . . . . . . . . . . . . . . .p p 27-46 27 28 29-31 32-34 35 Male connectors with Mixed-Layout . . . . . . . . . . . .p Female connectors with Mixed-Layout . . . . . . . . . .p Shifted polarization key position . . . . . . . . . . . . . . . .p Fixing hardware information . . . . . . . . . . . . . . . . . . .p CMM 320 Series CMM LF introduction page . . . . . . . . . . . . . . . . . . . . . . . . . .p Contact arrangements & configuration . . . . . . . . . . . . . . . . .p Male connectors with LF contacts . . . . . . . . . . . . . . . . . . . . .p Female connectors with LF contacts . . . . . . . . . . . . . . . . . . .p Mixed-Layout introduction page . . . . . . . . . . . . . . . . . . . . . .p 36-38 39-41 42 43-46 p 47-59 47 48 49-50 51-52 53 Male connectors with Mixed-Layout . . . . . . . . . . . .p 54-56 Female connectors with Mixed-Layout . . . . . . . . . .p 57-59 Fixing hardware information . . . . . . . . . . . . . . . . . . .p 69-74 CMM 340 Series CMM 340 Mixed-Layout introduction page . . . . . . . . . . . . . .p 60-61 Contact arrangements & configuration . . . . . . . . . . . . . . . . .p 62 Male connectors with Mixed-Layout . . . . . . . . . . . . . . . . . . .p 63-65 p 60-74 Female connectors with Mixed-Layout . . . . . . . . . . .p 66-68 Fixing hardware information . . . . . . . . . . . . . . . . . . .p 69-74 High frequency and high power contacts Insertion & part numbering information for HF & HP contacts series 30 . . . . . . . . . . . . . . . . . . .p 75 HF contacts series 30 . . . . . . . . . . . . . . . . . . . . . . . . .p 76-86 30-1300-xx (Male straight on PCB) . . . . . . . . . . . . . . . . . . . .p 76 30-2300-xx (Female straight on PCB) . . . . . . . . . . . . . . . . . .p 76 30-1400-xx (Male 90° PCB) . . . . . . . . . . . . . . . . . . . . . . . . . .p 77 30-2400-xx (Female 90° PCB) . . . . . . . . . . . . . . . . . . . . . . . .p 77 30-1500-CMM (Male 90° SMT without LF) . . . . . . . . . . . . .p 78 30-1500-12 (Male 90° SMT for CMM220) . . . . . . . . . . . . . .p 79 30-1500-12 (Male 90° SMT for CMM320) . . . . . . . . . . . . . .p 80 30-1600 (Male straight SMT for CMM220) . . . . . . . . . . . . . .p 81 30-2600 (Female straight SMT for CMM220) . . . . . . . . . . . .p 81 30-1312-ZS (Male straight crimp on cable) . . . . . . . . . . . . . .p 82 30-2312-ZS (Female straight crimp on cable) . . . . . . . . . . . .p 82 30-13xx-SS / ZS (Male straight crimp on cable) . . . . . . . . . .p 83 30-23xx-SS / ZS (Female straight crimp on cable) . . . . . . . .p 83 30-14xx-ZS (Male 90° crimp on cable) . . . . . . . . . . . . . . . . .p 84 30-24xx-ZS (Female 90° crimp on cable) . . . . . . . . . . . . . . .p 84 30-13xx-ZZ (Male straight on semi-rigid cable . . . . . . . . . .p 85 30-23xx-ZZ (Female straight on semi-rigid cable) . . . . . . . .p 85 30-14xx-ZZ (Male 90° on semi-rigid cable) . . . . . . . . . . . . .p 86 30-24xx-ZZ (Female 90° on semi-rigid cable) . . . . . . . . . . .p 86 HP contacts series 30 . . . . . . . . . . . . . . . . . . . . . . . . .p 87-93 30-3300-xx (Male straight on PCB) . . . . . . . . . . . . . . . . . . . .p 87 30-4300-xx (Female straight on PCB) . . . . . . . . . . . . . . . . . .p 87 30-3400-xx (Male 90°) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .p 88 30-4400-xx (Female 90°) . . . . . . . . . . . . . . . . . . . . . . . . . . . .p 88 Tools and accessories Cable instructions & assembly Index Notes p 75-102 30-3500 (Male 90° SMT) . . . . . . . . . . . . . . . . . . . . . .p 89 30-4500 (Female 90° SMT) . . . . . . . . . . . . . . . . . . . .p 89 30-3600 (Male straight SMT) . . . . . . . . . . . . . . . . . .p 90 30-4600 (Female straight SMT) . . . . . . . . . . . . . . . . .p 90 30-3500-CMM (Male 90° SMT Card Edge) . . . . . . .p 91 30-3500-12 (Male 90° SMT Card Edge CMM220) . .p 92 30-3500-12 (Male 90° SMT Card Edge CMM320) . .p 93 30-33xx (Male straight on cable) . . . . . . . . . . . . . . .p 94 30-43xx (Female straight on cable) . . . . . . . . . . . . .p 94 Insertion & part numbering information for HF & HP contacts series 22 . . . . . . . . . . .p 95 HF contacts series 22 . . . . . . . . . . . . . . . . . . .p 96-99 22-1300-xx (Male straight on PCB) . . . . . . . . . . . . .p 96 22-2300-xx (Female straight on PCB) . . . . . . . . . . .p 96 22-1400-xx (Male 90° PCB) . . . . . . . . . . . . . . . . . . .p 97 22-2400-xx (Female 90° PCB) . . . . . . . . . . . . . . . . .p 97 22-1312-ZS-xx (Male straight to crimp on cable) . .p 98 22-2312-ZS-xx (Female straight to crimp on cable) p 98 22-1320-ZZ (Male straight on cable) . . . . . . . . . . . .p 99 22-2320-ZZ (Female straight on cable) . . . . . . . . . .p 99 HP contacts series 22 . . . . . . . . . . . . . . . . . . .p 100-102 22-3300-xx (Male straight on PCB) . . . . . . . . . . . . .p 100 22-4300-xx (Female straight on PCB) . . . . . . . . . . .p 100 22-3400-xx (Male 90° on PCB) . . . . . . . . . . . . . . . .p 101 22-4400-xx (Female 90° on PCB) . . . . . . . . . . . . . . .p 101 22-33xx (Male straight on cable) . . . . . . . . . . . . . . .p 102 22-43xx (Female straight on cable) . . . . . . . . . . . . .p 102 p 103-112 p 113-122 p 123 p 124 123 Notes 124 Couv_rabat_2011.qxd:Mise en page 1 18/05/11 11:37 Page2 Dimension Tables CMM 100/200 SERIES CMM Specifications (with LF contacts) Manufacturer and designer of innovative interconnect solutions MATERIALS in male & female styles for LF contacts INSULATOR: Special PPS (Polyphenylene Sulfide Fiberglass filled thermoplastic) UL 94-V0 CMM SERIES 100 & 200 Male LF contacts number series 100 2 3 4 LF contacts number series 200 4 6 8 Length in mm A 2 4 6 Length in mm (Strap) B 6,7 8,7 10,7 Length in mm C 7,4 9,4 11,4 Length C with Latches fitted 7,8 9,8 11,8 5 10 8 12,7 13,4 13,8 6 12 10 14,7 15,4 15,8 7 14 12 16,7 17,4 17,8 8 16 14 18,7 19,4 19,8 9 18 16 20,7 21,4 21,8 10 20 18 22,7 23,4 23,8 11 22 20 24,7 25,4 25,8 12 24 22 26,7 27,4 27,8 13 26 24 28,7 29,4 29,8 14 28 26 30,7 31,4 31,8 15 30 28 32,7 33,4 33,8 16 32 30 34,7 35,4 35,8 17 34 32 36,7 37,4 37,8 18 36 34 38,7 39,4 39,8 19 38 36 40,7 41,4 41,8 20 40 38 42,7 43,4 43,8 21 42 40 44,7 45,4 45,8 22 44 42 46,7 47,4 47,8 23 46 44 48,7 49,4 49,8 24 48 46 50,7 51,4 51,8 25 50 48 52,7 53,4 53,8 • Radiation resistance • No humidity absorption • Oxygen free Note : PPS characteristics are recognized for space applications CMM SERIES 100 & 200 Female LF contacts number series 100 LF contacts number series 200 Length in mm A Length in mm B D E F G LF CONTACTS REFERENCE MARK NUMBER FOR CMM SERIES 200 Male & Female CMM 220 SERIES LF contacts number Distance between A axis B CMM SERIES 220 Length in mm Male & LF contacts Female reference mark number C D E F G 2 4 2 7 3 6 4 9 4 8 6 11 5 10 8 13 6 12 10 15 7 14 12 17 8 16 14 19 9 18 16 21 10 20 18 23 11 22 20 25 12 24 22 27 13 26 24 29 14 28 26 31 15 30 28 33 16 32 30 35 17 34 32 37 18 36 34 39 19 38 36 41 20 40 38 43 21 42 40 45 22 44 42 47 23 46 44 49 24 48 46 51 25 50 48 53 1 2 3 4 1 3 4 6 1 4 5 8 1 5 6 10 1 6 7 12 1 7 8 14 1 8 9 16 1 9 10 18 1 10 11 20 1 11 12 22 1 12 13 24 1 13 14 26 1 14 15 28 1 15 16 30 1 16 17 32 1 17 18 34 1 18 19 36 1 19 20 38 1 20 21 40 1 21 22 42 1 22 23 44 1 23 24 46 1 24 25 48 1 25 26 50 Special contacts number CMM 220 Male & Female Distance between A axis Special B contacts only Length in mm C LF contacts number 6 Distance between A 2 axis B 11 Length in mm C 17 CMM D 1 SERIES 320 E 2 Male & LF contacts F 3 Female reference mark G 4 number H 5 J 6 9 4 13 19 1 3 4 6 7 9 12 10 17 22 1 6 7 12 12 6 15 21 1 4 5 8 9 12 14 12 19 24 1 7 8 14 16 14 21 26 1 8 9 16 18 16 23 28 1 9 10 18 20 18 25 30 1 10 11 20 22 20 27 32 1 11 12 22 24 22 29 34 1 12 13 24 26 24 31 36 1 13 14 26 28 26 33 38 1 14 15 28 30 28 35 40 1 15 16 30 32 30 37 42 1 16 17 32 34 32 39 44 1 17 18 34 36 34 41 46 1 18 19 36 38 36 43 48 1 19 20 38 40 38 45 50 1 20 21 40 42 40 47 52 1 21 22 42 44 42 49 54 1 22 23 44 46 44 51 56 1 23 24 46 48 46 53 58 1 24 25 48 3 8 17 22 4 12 21 26 5 16 25 30 6 20 29 34 7 24 33 38 8 28 37 42 9 32 41 46 10 36 45 50 11 40 49 54 18 10 19 25 1 6 7 12 13 18 21 12 21 27 1 7 8 14 15 21 24 14 23 29 1 8 9 16 17 24 27 16 25 31 1 9 10 18 19 27 30 18 27 33 1 10 11 20 21 30 33 20 29 35 1 11 12 22 23 33 36 22 31 37 1 12 13 24 25 36 39 24 33 39 1 13 14 26 27 39 42 26 35 41 1 14 15 28 29 42 45 28 37 43 1 15 16 30 31 45 48 30 39 45 1 16 17 32 33 48 51 32 41 47 1 17 18 34 35 51 54 34 43 49 1 18 19 36 37 54 57 36 45 51 1 19 20 38 39 57 60 38 47 53 1 20 21 40 41 60 63 40 49 55 1 21 22 42 43 63 66 42 51 57 1 22 23 44 45 66 69 44 53 59 1 23 24 46 47 69 72 46 55 61 1 24 25 48 49 72 75 48 57 63 1 25 26 50 51 75 78 50 59 65 1 26 27 52 53 78 81 52 61 67 1 27 28 54 55 81 84 54 63 69 1 28 29 56 57 84 87 56 65 71 1 29 30 58 59 87 50 48 55 60 1 25 26 50 12 44 53 58 90 58 67 73 1 30 31 60 61 90 93 60 69 75 1 31 32 62 63 93 52 50 57 62 1 26 27 52 54 52 59 64 1 27 28 54 13 48 57 62 96 62 71 77 1 32 33 64 65 96 Female: Body : copper alloy / Ni + Au 0,2 µ Socket : beryllium copper / Ni + Au > 1,25µ 56 54 61 66 1 28 29 56 58 56 63 68 1 29 30 58 60 58 65 70 1 30 31 60 14 52 61 66 99 64 73 79 1 33 34 66 67 99 102 66 75 81 1 34 35 68 69 102 105 68 77 83 1 35 36 70 71 105 108 70 79 85 1 36 37 72 73 108 111 72 81 87 1 37 38 74 75 111 114 74 83 89 1 38 39 76 77 114 117 76 85 91 1 39 40 78 79 117 OMM SERIES MICRO-CIRCULAR CONNECTORS High density of contacts in smallest circular connector shape Space saving feature Security of connection Light weight Lockable captive fixing hardware ELECTRICAL • All contacts 3 A max. @ 25°C 2.2 A max. @ 85°C • Working voltage (sea level) Tested at 800 V DC • Proof voltage Tested at 1 200 V DC • Contact resistance (initially) max. 10 mΩ • Insulation resistance 1 000 MΩ min. MECHANICAL 15 56 65 70 • Mechanical operations Up to 2500 cycles • Contact insertion and withdrawal force 2 N max. / 0.2 N min. per contact • Contact retention in insulator 10 N min. • Contact replacement in insulator 1-3 cycles (Crimp contacts only) ENVIRONMENTAL 120 78 87 93 1 40 41 80 81 120 • Temperature cycling From - 60°C to + 260°C Reflow solder process compatible (+260°C) • Vibration severity 0.75 mm, 10 g RMS 6 hours long random with superimposed sinusoid. No intermittencies measured when using an H.S.L.I (High Speed Logic Interrupt) detector with a trip threshold of 2 ns. MIL-DTL-55302F Test Condition III [147.1 m/s2 (15 gn) peak] • Shock severity 100 g for 6 ms • Solvent resistance CMM 340 SERIES CMM 340 Male & Female Special contacts only 3 2mm pitch high density robust metal shielded micro connector Self cabling connector Simple and easy to design-in New alternative under MIL-DTL-83513G or MIL-DTL-55302F test routine Very flexible custom design (fixing hardware, contacts…) Female: Body : copper alloy / Ni + Au > 0,2 µ Socket : beryllium copper / Ni + Au > 1,25µ • Latch : Beryllium copper/plated nickel (CMM 100/200 series only) in male & female styles for LF contacts 15 8 17 23 1 5 6 10 11 15 MICRO-D MIX™ DMM SERIES MICRO-CONNECTORS FIXING HARDWARE: • Jackscrew: Stainless steel. in male & female styles for HF/HP contacts 2 4 13 18 CMM 320 SERIES CRIMP LF CONTACTS : Male: Body : copper alloy / Ni + Au > 1µ in male & female styles for LF contacts 4 6 8 10 2 4 6 8 9 11 13 15 14 16 18 20 1 1 1 1 2 3 4 5 3 4 5 6 4 6 8 10 CMM 220 SERIES P.C. LF CONTACTS : Male: Tail : copper alloy / Ni + Au flash 0,1µ Contact area : copper alloy / Ni + Au > 1µ MICROFLEX HARNESS SOLUTION Low weight: save up to -30% vs. bulky cable Smaller space-factor 2 in 1 technology with CMM & CRIMPFLEX Avionic & aerospace MIL comply High quality of crimp (gaz tie) High productivity: 2 to 30 contacts in 1 crimp 4D-FLOATING CONNECTORS 4D tolerance absorption: 4D = 3 axial movements + 1 rotation High efficiency “Bone design” (round shape and 4 spring-lips contact) Complies with MIL-DTL-55302F Auto alignment feature Adaptable to customer requests CUSTOM PRODUCTS You can rely on our R&D department know-how and long experience. Our permanent innovation was recognized and labelized as "highly Innovative" by the European Union Our in-house production and assembly capacity offers you the possibility to create customized products : stamping and moulding, micro-screw machining, laser cut, CNC, specific machinery development, clean room, measure and test lab. Fully integrated industrial company, Nicomatic can reduce your risks, can secure your development and achieve the solution that will make the difference on the market. in male & female styles for HF/HP contacts Special contacts number 4 6 8 Distance between A 2,5 5 7,5 axis B 12,5 15 17,5 Length in mm C 18,5 21 23,5 10 10 20 26 12 12,5 22,5 28,5 14 15 25 31 16 17,5 27,5 33,5 18 20 30 36 20 22,5 32,5 38,5 22 25 35 41 24 27,5 37,5 43,5 26 30 40 46 28 32,5 42,5 48,5 30 35 45 51 32 37,5 47,5 53,5 34 40 50 56 36 42,5 52,5 58,5 38 45 55 61 40 47,5 57,5 63,5 42 50 60 66 44 52,5 62,5 68,5 46 55 65 71 48 57,5 67,5 73,5 50 60 70 76 52 62,5 72,5 78,5 54 65 75 81 56 67,5 77,5 83,5 58 70 80 86 60 72,5 82,5 88,5 62 75 85 91 Note : The CMM micro-connectors are designed to meet or exceed the relevant electrical and environmental performances described in MIL-DTL-55302F & BS-9525-F0033 standards. 64 77,5 87,5 93,5 4 Date of issue : May 2011 Catalogue reference : C.CMM.1000/GB NICOMATIC maintains a policy of ongoing development and improvement. It therefore reserves the right to change design, dimensions and specifications without notice. All information stated inside this catalogue is not contractual and subject to change (eg. standard connector configurations). Copyright 2011 by NICOMATIC (All Rights Reserved). 125 HEADQUARTER SUBSIDIARIES FRANCE T:+33 (0)4 50 36 13 85 france@nicomatic.com UNITED STATES T:+1 21 54 44 95 80 usa@nicomatic.com SOUTH KOREA T: +82 (0)2 553 6822 korea@nicomatic.com CHINA T:+86 (0)22 23 85 88 36 china@nicomatic.com JAPAN T: +81 (0)80 2138 0909 japan@nicomatic.com INDIA T: +91 80 421 315 74 india@nicomatic.com SINGAPORE T: +65 62 62 12 80 singapore@nicomatic.com UNITED KINGDOM T: +44 (0) 11 83 80 10 33 uk@nicomatic.com CANADA T: +41 (0) 438 885 3395 canada@nicomatic.com GERMANY T: +49 (0)33 203 878 801 germany@nicomatic.com TAIWAN T: +886 (0)2 2311 2667 taiwan@nicomatic.com MEMBER OF Gifas - Eden Aerospace cluster TURKEY T: +90 (0) 312 504 37 29 turkey@nicomatic.com WEBSITE nicomatic.com CAREER COME & JOIN US ◆ Improving technology ◆ Diversity & gender equality ◆ We promote initiative & responsibility READY TO JOIN OUR TEAM? recruitment@nicomatic.com
C13064-P 价格&库存

很抱歉,暂时无法提供与“C13064-P”相匹配的价格&库存,您可以联系我们找货

免费人工找货