0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
56.44.9.012.0000

56.44.9.012.0000

  • 厂商:

    FINDER

  • 封装:

  • 描述:

  • 数据手册
  • 价格&库存
56.44.9.012.0000 数据手册
56 SERIES Miniature power relays 12 A 56 SERIES 56.32/56.34 Plug-in - 12 A Power relay, 2 & 4 pole • Flange mount option (Faston 187, 4.8 x 0.5 mm termination) • AC coils & DC coils • Lockable test button and mechanical flag indicator • Cadmium Free contacts (standard version) • Contact material options • 96 series sockets • Coil EMC suppression • Accessories • European Patent 56.32-0300 A • 2 or 4 pole changeover contact • Plug-in/Faston 187 56.32 • 2 pole normally open contact (≥ 1.5 mm gap) • Plug-in/Faston 187 56.32-0300 56.34 * For 4 CO (4PDT) only. For UL ratings see: “General technical information” page V 56.32 56.34 56.32-0300 4 CO (4PDT) 2NO (DPST-NO) - ≥ 1.5 mm gap Contact specification Contact configuration 2 CO (DPDT) Rated current/Maximum peak current Rated voltage/ Maximum switching voltage A V AC 12/20 12/20 250/400 250/400 VA 3000 3000 Rated load AC15 (230 V AC)VA 700 700 Single phase motor rating (230 V AC)kW 0.55 0.55 Breaking capacity DC1: 30/110/220 VA 12/0.5/0.25 12/1/0.5 Minimum switching load 500 (10/5) 500 (10/5) AgNi AgNi Rated load AC1 mW (V/mA) Standard contact material Coil specification Nominal voltage (UN)  V AC (50/60 Hz) V DC Rated power AC/DC Operating range VA (50 Hz)/W 6 - 12 - 24 - 48 - 60 - 110 - 120 - 230 - 240 - 400* 6 - 12 - 24 - 48 - 60 - 110 - 125 - 220 1.5/1 2/1.3 AC DC (0.8…1.1)UN (0.8…1.1)UN — 1.5/— (0.85…1.1)UN (0.85…1.1)UN — Holding voltage AC/DC 0.8 UN / 0.6 UN 0.85 UN/— Must drop-out voltage AC/DC 0.2 UN / 0.1 UN 0.2 UN/— Mechanical life AC/DC cycles 20 · 106/50 · 106 20 · 106/— Electrical life at rated load AC1 cycles 100 · 10 100 · 103 Technical data XI-2016, www.findernet.com Operate/release time Insulation between coil and contacts (1.2/50 μs) Dielectric strength between open contacts Ambient temperature range Environmental protection 3 ms 8/3 10/4 8/4 kV 4 5 4 V AC °C 1000 2000 –40…+70 –40…+70 RT I RT I Approvals (according to type) 1 56 SERIES 56 SERIES Miniature power relays 12 A 56.42/56.44 Printed circuit mount 12 A Power relay • 2 & 4 pole • AC coils & DC coils • Cadmium Free contacts (standard version) • Contact material option • RT III (wash tight) option available • 2 or 4 pole changeover contact • PCB mount 56.44 • 2 pole normally open contact (≥ 1.5 mm gap) • PCB mount 56.42-0300 56.42 * For 4 CO (4PDT) only. For UL ratings see: “General technical information” page V 56.42 Copper side view 56.44 Copper side view 56.42-0300 Copper side view 4 CO (4PDT) 2NO (DPST-NO) - ≥ 1.5 mm gap Contact specification Contact configuration 2 CO (DPDT) Rated current/Maximum peak current Rated voltage/ Maximum switching voltage A V AC 12/20 12/20 250/400 250/400 VA 3000 3000 Rated load AC15 (230 V AC)VA 700 700 Single phase motor rating (230 V AC)kW 0.55 0.55 Breaking capacity DC1: 30/110/220 VA 12/0.5/0.25 12/1/0.5 Minimum switching load 500 (10/5) 500 (10/5) AgNi AgNi Rated load AC1 mW (V/mA) Standard contact material Coil specification Nominal voltage (UN)  V AC (50/60 Hz) V DC Rated power AC/DC Operating range VA (50 Hz)/W 6 - 12 - 24 - 48 - 60 - 110 - 120 - 230 - 240 - 400* 6 - 12 - 24 - 48 - 60 - 110 - 125 - 220 1.5/1 2/1.3 AC DC (0.8…1.1)UN (0.8…1.1)UN — 1.5/— (0.85…1.1)UN (0.85…1.1)UN — Holding voltage AC/DC 0.8 UN / 0.6 UN 0.85 UN/— Must drop-out voltage AC/DC 0.2 UN / 0.1 UN 0.2 UN/— Mechanical life AC/DC cycles 20 · 106/50 · 106 20 · 106/— Electrical life at rated load AC1 cycles 100 · 10 100 · 103 Technical data Operate/release time Insulation between coil and contacts (1.2/50 μs) Dielectric strength between open contacts Ambient temperature range Environmental protection Approvals (according to type) 2 3 ms 8/3 10/4 8/4 kV 4 5 4 V AC °C 1000 2000 –40…+70 –40…+70 RT I RT I XI-2016, www.findernet.com A 56.42-0300 56 SERIES Miniature power relays 12 A 56 SERIES Ordering information Example: 56 series plug-in relay, 2 CO (DPDT), 12 V DC coil, lockable test button and mechanical indicator. 5 6 . 3 A B C D 2 . 9 . 0 1 2 . 0 0 4 0 Series A: Contact material 0 = Standard AgNi 2 = AgCdO 4 = AgSnO2 Type 3 = Plug-in 4 = PCB B: Contact circuit 0 = CO (nPDT) 3 = NO (nPST), ≥ 1.5 mm contact gap No. of poles 2 = 2 pole, 12 A 4 = 4 pole, 12 A Coil version 8 = AC (50/60 Hz) 9 = DC Coil voltage See coil specifications Selecting features and options: only combinations in the same row are possible. Preferred selections for best availability are shown in bold. Type 56.32 56.34 56.42 56.44 Coil version A B C D AC AC AC DC 0-2-4 0-2-4 0-2-4 0-2-4 0 0 3 0 0-2-3-4-5 54 0-3-5 0-2-4-6-7-8-9 0 / 0 0 DC 0-2-4 0 74 - 94 / AC 0-2-4 0 0-2-3-4-5 0-6-8 AC 0-2-4 0 54 / DC DC DC AC AC - DC 0-2-4 0-2-4 0-2-4 0-2-4 0-2-4 0 0 0 0-3 0 0-2-4-6-7 74 0 0 0 0-6-8 / 0-1 0-1 0-1 A D: Special versions 0 = Standard 1 = Wash tight (RT III) for 56.42 and 56.44 only 6 = Rear flange mount (4 pole only) 8 = Rear 35 mm rail mount (4 pole only) For other mounting options see page 6 C: Options 0 = None 2 = Mechanical indicator 3* = LED (AC) 4 = Lockable test button+mechanical indicator 5* = Lockable test button + LED (AC) 54* = Lockable test button + LED (AC) + mechanical indicator 6* = Double LED (DC non-polarized) 7* = Lockable test button + double LED (DC non-polarized) 74* = Lockable test button + double LED (DC non-polarized) + mechanical indicator 8* = LED + diode (DC, polarity positive to pin 7) for 56.32 only 9* = Lockable test button + LED + diode (DC, polarity positive to pin 7) for 56.32 only 94* = Lockable test button + LED + diode (DC, polarity positive to pin 7) + mechanical indicator for 56.32 only *O  ptions not available for 220 V DC and 400 V AC versions. Special versions for Rail Applications on request C: Option 6, 7, 74 Double LED (DC non-polarized) O P A PEAN N T E PEAN 3 XI-2016, www.findernet.com 1 2 T EUR C: Option 8, 9, 94 LED + diode (DC, polarity positive to pin 7) (56.32 only) O C: Option 3, 5, 54 LED (AC) EUR Descriptions: options and special versions Lockable test button and mechanical flag indicator (0040, 0050, 0054, 0070, 0074, 0090, 0094) The dual-purpose Finder test button can be used in two ways: Case 1) The plastic pip (located directly above the test button) remains intact. In this case, when the test button is pushed, the contacts operate. When the test button is released the contacts return to their former state. Case 2) The plastic pip is broken-off (using an appropriate cutting tool). In this case, (in addition to the above function), when the test button is pushed and rotated, the contacts are latched in the operating state, and remain so until the test button is rotated back to its former position. In both cases ensure that the test button actuation is swift and decisive. 3 56 SERIES Miniature power relays 12 A 56 SERIES Technical data Insulation according to EN 61810-1 Nominal voltage of supply system V AC Rated insulation voltage V AC Pollution degree Insulation between coil and contact set Type of Insulation Overvoltage category Rated impulse voltage kV (1.2/50 μs) Dielectric strength V AC Insulation between adjacent contacts Type of insulation Overvoltage category Rated impulse voltage kV (1.2/50 μs) Dielectric strength V AC Insulation between open contacts Type of disconnection Overvoltage category Rated impulse voltage kV (1.2/50 μs) Dielectric strength V AC/kV (1.2/50 μs) Conducted disturbance immunity Burst (5…50)ns, 5 kHz, on A1 - A2 Surge (1.2/50 μs) on A1 - A2 (differential mode) Other data Bounce time: NO/NC ms Vibration resistance (5…55)Hz: NO/NC g Shock resistance g Power lost to the environment without contact current W with rated current W Recommended distance between relays mounted on PCB mm 2 CO - 4 CO 230/400 250 3 400 2 2 NO 230/400 250 3 400 2 Basic III 4 2500 Basic III 4 2500 Basic III 4 2500 Basic III 4 2500 Micro-disconnection — — 1000/1.5 Full-disconnection* II 2.5 2000/3 EN 61000-4-4 EN 61000-4-5 level 4 (4 kV) level 4 (4 kV) 1/4 (changeover) 17/14 20/14 1 (56.32, 56.42) 3.8 (56.32, 56.42) ≥ 5 3/— (normally open) 1.3 (56.34, 56.44) 6.9 (56.34, 56.44) Contact specification F 56 - Electrical life (AC) v contact current 2 - 4 pole relays Cycles Resistive load - cosφ = 1 Inductive load - cosφ = 0.4 H 56 - Maximum DC1 breaking capacity Changeover version H 56 - M  aximum DC1 breaking capacity Normally open version contacts in series DC voltage (V) DC voltage (V) • When switching a resistive load (DC1) having voltage and current values under the curve, an electrical life of ≥ 100 · 103 can be expected. • In the case of DC13 loads, the connection of a diode in parallel with the load will permit a similar electrical life as for a DC1 load. Note: the release time of the load will be increased. 4 XI-2016, www.findernet.com DC breaking current (A) contacts in series DC breaking current (A) A * Only in applications where over voltage category II is permitted. In applications of over voltage category III: Micro-disconnection. 56 SERIES Miniature power relays 12 A 56 SERIES Coil specifications DC coil data, 2 pole relay Nominal voltage UN V 6 12 24 48 60 110 125 220 Coil code 9.006 9.012 9.024 9.048 9.060 9.110 9.125 9.220 AC coil data, 2 pole relay Operating range Umin V 4.8 9.6 19.2 38.4 48 88 100 176 Umax V 6.6 13.2 26.4 52.8 66 121 138 242 Resistance R Ω 40 140 600 2400 4000 12500 17300 54000 Rated coil consumption I at UN mA 150 86 40 20 15 8.8 7.2 4 Nominal voltage UN V 6 12 24 48 60 110 120 230 240 Coil code 8.006 8.012 8.024 8.048 8.060 8.110 8.120 8.230 8.240 Operating range Umin* V 4.8 9.6 19.2 38.4 48 88 96 184 192 Resistance Umax V 6.6 13.2 26.4 52.8 66 121 132 253 264 R Ω 12 50 190 770 1200 3940 4700 17000 19100 A Rated coil consumption I at UN (50 Hz) mA 200 97 53 25 21 12.5 12 6 5.3 * Umin = 0.85 UN for normally open version. DC coil data, 4 pole relay Nominal voltage UN V 6 12 24 48 60 110 125 220 Coil code 9.006 9.012 9.024 9.048 9.060 9.110 9.125 9.220 AC coil data, 4 pole relay Operating range Umin V 5.1 10.2 20.4 40.8 51 93.5 107 187 Umax V 6.6 13.2 26.4 52.8 66 121 138 242 Resistance R Ω 32.5 123 490 1800 3000 10400 14200 44000 R 56 - DC coil operating range v ambient temperature 2 pole relay Rated coil consumption I at UN mA 185 97 49 27 20 10.5 8.8 5 Nominal voltage UN V 6 12 24 48 60 110 120 230 240 400 Coil code 8.006 8.012 8.024 8.048 8.060 8.110 8.120 8.230 8.240 8.400 Operating range Umin V 4.8 9.6 19.2 38.4 48 88 96 184 192 320 Resistance Umax V 6.6 13.2 26.4 52.8 66 121 132 253 264 440 R Ω 5.7 22 81 380 600 1900 2560 7700 10000 26000 Rated coil consumption I at UN (50 Hz) mA 300 150 90 37 30 16.5 13.4 9 7.5 4.9 R 56 - AC coil operating range v ambient temperature 2 pole relay 1 1 normally open version 2 changeover version R 56 - DC coil operating range v ambient temperature 4 pole relay 2 2 R 56 - A  C coil operating range v ambient temperature 4 pole relay 1 1 XI-2016, www.findernet.com 2 changeover version 1 - Max. permitted coil voltage. 2 - Min. pick-up voltage with coil at ambient temperature. 2 1 - Max. permitted coil voltage. 2 - Min. pick-up voltage with coil at ambient temperature. 5 56 SERIES 56 SERIES Miniature power relays 12 A Accessories Top flange mount adaptor for 56.32 056.25 A 056.25 with relay 056.25 056.25 with relay Rear flange mount adaptor for 56.32 056.26 056.26 056.26 with relay 056.26 056.26 with relay Top 35 mm rail (EN 60715) adaptor for 56.32 056.27 056.27 056.27 with relay 056.27 056.27 with relay Top flange mount adaptor for 56.34 056.45 056.45 056.45 with relay 056.45 056.45 with relay Top 35 mm rail (EN 60715) adaptor for 56.34 056.47 056.47 056.47 with relay 056.47 056.47 with relay Sheet of marker tags for relay type 56.34, plastic, 48 tags, 6 x 12 mm, for CEMBRE’s thermal transfer printers 060.48 6 060.48 XI-2016, www.findernet.com 056.25 96 SERIES Sockets and accessories for 56 series relays 56 SERIES Screw terminal (Box clamp) socket panel or 35 mm rail mount (EN 60715) For relay type 96.02 Blue 56.32 96.02.0 Black 96.04 Blue 56.34 96.04.0 Black A Accessories Metal retaining clip (supplied with socket - packaging code SMA) Plastic retaining and release clip (supplied with socket - packaging code SPA) 6-way jumper link Identification tag Modules (see table below) Timer modules (see table below) Sheet of marker tags for retaining and release clip 094.91.3, plastic, 48 tags, 6 x 12 mm, for CEMBRE's thermal transfer printers Technical data Rated values Dielectric strength Protection category Ambient temperature 96.02 Approvals (according to type): 96.04 Approvals (according to type): Screw torque 094.71 094.91.3 094.06 095.00.4 99.02 86.30 096.71 094.91.30 094.06.0 — — 090.00.2 — — 86.00, 86.30 060.48 — 10 A - 250 V 2 kV AC IP 20 °C –40…+70 (see diagram L96) Nm 0.8 Wire strip length Max. wire size for 94.02/04 sockets 094.91.3 mm 8 solid wire mm2 1 x 6 / 2 x 2.5 AWG 1 x 10 / 2 x 14 stranded wire 1 x 4 / 2 x 2.5 1 x 12 / 2 x 14 Rated current (A) L 96 - Rated current vs ambient temperature 96.02 P A N T E O O T EUR EUR 96.02 PEAN 96.04 6-way jumper link for 96.02 socket Rated values 094.06 (blue) 10 A - 250 V 86 series timer modules Multi-voltage: (12…240)V AC/DC; Multi-functions: AI, DI, SW, BE, CE, DE, EE, FE; (0.05 s…100 h) (12…24)V AC/DC; Bi-function: AI, DI; (0.05 s…100 h) (110…125)V AC; Bi-function: AI, DI; (0.05 s…100 h) (230…240)V AC; Bi-function: AI, DI; (0.05 s…100 h) 86.00.0.240.0000 86.30.0.024.0000 86.30.8.120.0000 86.30.8.240.0000 96.04 094.06.0 (black) PEAN 094.06 86.00 Approvals (according to type): XI-2016, www.findernet.com 86.30 99.02 Approvals (according to type): DC Modules with non-standard polarity (+A2) on request. 99.02 coil indication and EMC suppression modules for 96.02 and 96.04 sockets Diode (+A1, standard polarity) (6…220)V DC 99.02.3.000.00 LED(6…24)V DC/AC 99.02.0.024.59 LED(28…60)V DC/AC 99.02.0.060.59 LED(110…240)V DC/AC 99.02.0.230.59 LED + Diode (+A1, standard polarity) (6…24)V DC 99.02.9.024.99 LED + Diode (+A1, standard polarity) (28…60)V DC 99.02.9.060.99 LED + Diode (+A1, standard polarity) (110…220)V DC 99.02.9.220.99 LED + Varistor (6…24)V DC/AC 99.02.0.024.98 LED + Varistor (28…60)V DC/AC 99.02.0.060.98 LED + Varistor (110…240)V DC/AC 99.02.0.230.98 RC circuit (6…24)V DC/AC 99.02.0.024.09 RC circuit (28…60)V DC/AC 99.02.0.060.09 RC circuit (110…240)V DC/AC 99.02.0.230.09 Residual current by-pass (110…240)V AC 99.02.8.230.07 7 56 SERIES 96 SERIES Sockets and accessories for 56 series relays Screw terminal (Plate clamp) socket panel or 35 mm rail (EN 60715) mount For relay type A 96.72 Blue 56.32 96.72.0 Black 96.74 Blue 56.34 96.74.0 Black Accessories 96.72 Approvals (according to type): Metal retaining clip (supplied with socket - packaging code SMA) Modules (see table below) Technical data Rated values Dielectric strength Protection category Ambient temperature Screw torque Wire strip length Max. wire size for 96.72 and 96.74 sockets 094.71 99.01 096.71 12 A - 250 V 2 kV AC IP 20 °C –40…+70 Nm 0.8 mm 10 solid wire mm2 1 x 4 / 2 x 4 stranded wire 1 x 4 / 2 x 2.5 AWG 1 x 12 / 2 x 12 1 x 12 / 2 x 14 96.74 Approvals (according to type): 96.72 99.01 Approvals (according to type): 99.01 coil indication and EMC suppression modules for types 96.72 and 96.74 sockets Blue* Diode (+A1, standard polarity)  (6…220)V DC 99.01.3.000.00 Diode (+A2, non-standard polarity)  (6…220)V DC 99.01.2.000.00 LED  (6…24)V DC/AC 99.01.0.024.59 LED  (28…60)V DC/AC 99.01.0.060.59 LED  (110…240)V DC/AC 99.01.0.230.59 LED + Diode (+A1, standard polarity)  (6…24)V DC 99.01.9.024.99 LED + Diode (+A1, standard polarity)  (28…60)V DC 99.01.9.060.99 LED + Diode (+A1, standard polarity)  (110…220)V DC 99.01.9.220.99 LED + Diode (+A2, non-standard polarity)  (6…24)V DC 99.01.9.024.79 LED + Diode (+A2, non-standard polarity)  (28…60)V DC 99.01.9.060.79 LED + Diode (+A2, non-standard polarity)  LED + Varistor  LED + Varistor  LED + Varistor  RC circuit  RC circuit  RC circuit  Residual current by-pass  (110…220)V DC 99.01.9.220.79 (6…24)V DC/AC (28…60)V DC/AC (110…240)V DC/AC (6…24)V DC/AC (28…60)V DC/AC (110…240)V DC/AC (110…240)V AC 99.01.0.024.98 99.01.0.060.98 99.01.0.230.98 99.01.0.024.09 99.01.0.060.09 99.01.0.230.09 99.01.8.230.07 XI-2016, www.findernet.com * Modules in Black housing are available on request. Green LED is standard. Red LED available on request. 96.74 8 96 SERIES Sockets and accessories for 56 series relays 56 SERIES PCB socket 96.12 Approvals (according to type): 96.12 (blue) 56.32 For relay type Accessories 96.12.0 (blue) 96.14 (blue) 56.34 96.14.0 (blue) A 094.51 Technical data Rated values Dielectric strength Protection category Ambient temperature 15 A - 250 V 2 kV AC IP 20 °C –40…+70 Copper side view 96.12 Copper side view 96.14 Packaging codes How to code and identify retaining clip and packaging options for sockets. Example: XI-2016, www.findernet.com 9 6 . 7 9 6 . 7 4 4 S M A A Standard packaging SM SP Metal retaining clip Plastic retaining clip Without retaining clip 9
56.44.9.012.0000 价格&库存

很抱歉,暂时无法提供与“56.44.9.012.0000”相匹配的价格&库存,您可以联系我们找货

免费人工找货