  • 厂商:

    FINDER

  • 封装:

    -

  • 描述:

  • 数据手册
  • 价格&库存
95.95.3 数据手册
40 40 Series - Miniature PCB/Plug-in relays 8 - 10 - 12 - 16 A Features 40.31 40.51 SERIES 40.52 1 & 2 Pole relay range 40.31 - 1 Pole 10 A (3.5 mm pin pitch) 40.51 - 1 Pole 10 A (5 mm pin pitch) 40.52 - 2 Pole 8 A (5 mm pin pitch) A PCB mount - direct or via PCB socket 35 mm rail mount - via screw and screwless sockets DC coils (standard or sensitive) & AC coils Cadmium Free contact material • 8 mm, 6 kV (1.2/50 μs) isolation, coil-contacts • UL Listing (certain relay/socket combinations) • Flux proof: RT II standard, (RT III option) • 95 series sockets • Coil EMC suppression • Timer accessories 86 series • • FOR UL RATINGS SEE: “General technical information” page V For outline drawing see page 10 3.5 mm contact pin pitch 1 Pole 10 A • PCB or 95 series sockets 5 mm contact pin pitch 1 Pole 10 A • PCB or 95 series sockets 5 mm contact pin pitch 2 Pole 8 A • PCB or 95 series sockets • • • • • • Copper side view Copper side view Copper side view Pin length 5.3 mm for PCB or sockets Pin length 5.3 mm for PCB or sockets Pin length 5.3 mm for PCB or sockets 1 CO (SPDT) 1 CO (SPDT) 2 CO (DPDT) Contact specification Contact configuration Rated current/Maximum peak current A Rated voltage/Maximum switching voltage V AC 10/20 10/20 8/15 250/400 250/400 250/400 Rated load AC1 VA 2,500 2,500 2,000 Rated load AC15 (230 V AC) VA 500 500 400 kW 0.37 0.37 0.3 10/0.3/0.12 10/0.3/0.12 8/0.3/0.12 300 (5/5) 300 (5/5) 300 (5/5) AgNi AgNi AgNi Single phase motor rating (230 V AC) Breaking capacity DC1: 30/110/220 V Minimum switching load A mW (V/mA) Standard contact material Coil specification Nominal voltage (UN) V AC (50/60 Hz) V DC 6 - 12 - 24 - 48 - 60 - 110 - 120 - 230 - 240 5 - 6 - 7 - 9 - 12 - 14 - 18 - 21 - 24 - 28 - 36 - 48 - 60 - 90 - 110 - 125 Rated power AC/DC/sens. DC VA (50 Hz)/W/W 1.2/0.65/0.5 1.2/0.65/0.5 1.2/0.65/0.5 Operating range (0.8…1.1)UN (0.8…1.1)UN (0.8…1.1)UN AC DC/sens. DC (0.73…1.5)UN/(0.73…1.5)UN (0.73…1.5)UN/(0.73…1.5)UN (0.73…1.5)UN/(0.73…1.5)UN Holding voltage AC/DC 0.8 UN /0.4 UN 0.8 UN /0.4 UN 0.8 UN /0.4 UN Must drop-out voltage AC/DC 0.2 UN /0.1 UN 0.2 UN /0.1 UN 0.2 UN /0.1 UN Technical data Mechanical life cycles 10 · 106 10 · 106 10 · 106 Electrical life at rated load AC1 cycles 200 · 103 200 · 103 100 · 103 7/3 - (12/4 sensitive) 7/3 - (12/4 sensitive) 7/3 - (12/4 sensitive) Insulation between coil and contacts (1.2/50 μs) kV 6 (8 mm) 6 (8 mm) 6 (8 mm) Dielectric strength between open contacts V AC 1,000 1,000 1,000 –40…+85 –40…+85 –40…+85 RT II** RT II** RT II** VI-2014, www.findernet.com Operate/release time Ambient temperature range Environmental protection ms °C Approvals (according to type) ** See general technical information “Guidelines for automatic flow solder processes” page II . 1 40 SERIES 40 Series - Miniature PCB/Plug-in relays 8 - 10 - 12 - 16 A Features 40.xx.6 40.61 - 1 Pole 16 A (5 mm pin pitch) 40.xx.6 - Bistable versions of the 40.31, 40.51, 40.52 & 40.61 relays PCB mount - direct or via PCB socket 35 mm rail mount - via screw and screwless sockets DC coils & AC coils Cadmium Free option available • 8 mm, 6 kV (1.2/50 μs) isolation, coil-contacts • UL Listing (certain 40.61 relay/socket combinations) • Flux proof: RT II standard, (RT III option) • 95 series sockets • Coil EMC suppression • Timer accessories 86 series • • 5 mm contact pin pitch 1 Pole 16 A • PCB or 95 series sockets • • Bistable (single coil) versions of 40.31/51/52/61 • PCB or 95 series sockets • Bistable version (1 coil) types: 40.31.6... 40.51.6... 40.52.6... 40.61.6... For wiring diagrams see page 9 FOR UL RATINGS SEE: “General technical information” page V Copper side view Pin length 5.3 mm for PCB or sockets For outline drawing see page 10 Pin length 5.3 mm for PCB or sockets Contact specification Contact configuration 1 CO (SPDT) Rated current/Maximum peak current A Rated voltage/Maximum switching voltage V AC 16/30* 250/400 See relays Rated load AC1 VA 4,000 40.31 Rated load AC15 (230 V AC) VA 750 40.51 0.55 40.52 16/0.3/0.12 40.61 Single phase motor rating (230 V AC) kW Breaking capacity DC1: 30/110/220 V Minimum switching load A mW (V/mA) * With the AgSnO2 material the maximum peak current is 120 A - 5 ms on normally open contact. 500 (10/5) AgCdO Standard contact material Coil specification Nominal voltage (UN) V AC (50/60 Hz) 6 - 12 - 24 - 48 - 60 - 110 - 120 - 230 - 240 5 - 6 - 12 - 24 - 48 - 110 V DC ***See table Rated power AC/DC/sens. DC VA (50 Hz)/W/W 1.2/0.65/0.5 1.0/1.0/— Operating range (0.8…1.1)UN (0.8…1.1)UN AC 5 - 6 - 12 - 24 - 48 - 110 (0.73…1.5)UN/(0.8…1.5)UN (0.8…1.1)UN/— Holding voltage AC/DC 0.8 UN /0.4 UN — Must drop-out voltage AC/DC 0.2 UN /0.1 UN — DC/sens. DC *** Nominal voltage (UN): 5 - 6 - 7 - 9 - 12 - 14 - 18 - 21 24 - 28 - 36 - 48 - 60 - 90 110 - 125 V DC Technical data Mechanical life cycles 10 · 106 See relays Electrical life at rated load AC1 cycles 100 · 103 40.31 Operate/release time ms 7/3 - (12/4 sensitive) 40.51 Insulation between coil and contacts (1.2/50 μs) kV 6 (8 mm) 40.52 Dielectric strength between open contacts V AC 1,000 40.61 –40…+85 Min. impulse duration RT II** ≥ 20 ms Ambient temperature range Environmental protection °C Approvals (according to type) 2 ** See general technical information “Guidelines for automatic flow solder processes” page II. VI-2014, www.findernet.com A 40.61 40 Series - Miniature PCB/Plug-in relays 8 - 10 - 12 - 16 A Features 40.31 40 SERIES 40.61 1 Pole relay range 40.31 - 1 Pole 12 A (3.5 mm pin pitch) 40.61 - 1 Pole 16 A (5 mm pin pitch) A Pin length 3.5 mm for pcb mount Pin length 5.3 mm as Plug-in relay • DC standard (0.65 W) or sensitive (0.5 W) coils available • Cadmium Free contact material available • 6 kV (1.2/50 μs) isolation coil-contacts • 8 mm creepage and clearance distances between coil and contacts • Meets EN 60335-1 glow wire requirements • Flux proof: RT II standard or wash tight RT III • AC inductive load rating (related to AC15 utilisation category) 4 A 250 V approved according to EN 61810-1:2008 (Annex B tables B1, B2, B3) • • 3.5 mm contact pin pitch 1 Pole 12 A (on PCB; 10 A with socket) • PCB or 95 series sockets 5 mm contact pin pitch 1 Pole 16 A • PCB or 95 series sockets • • • • Copper side view Copper side view Pin length 3,5 mm for PCB only Pin length 3,5 mm for PCB only Pin length 5.3 mm for PCB or Pin length 5.3 mm for PCB or sockets sockets * mounted on sockets ≤ 10 A For outline drawing see page 10 See ordering information See ordering information 1 CO (SPDT) 1 CO (SPDT) Contact specification Contact configuration Rated current/Maximum peak current A Rated voltage/Maximum switching voltage V AC 12*/20 16/30 250/400 250/400 Rated load AC1 VA 3,000 4,000 Rated load AC15 (230 V AC) VA 1,000 1,000 kW 0.55 0.55 12/0.3/0.12 16/0.3/0.12 300 (5/5) 500 (10/5) AgNi AgCdO Single phase motor rating (230 V AC) Breaking capacity DC1: 30/110/220 V Minimum switching load A mW (V/mA) Standard contact material Coil specification Nominal voltage (UN) V AC (50/60 Hz) — — 12 - 24 12 - 24 W 0.65/0.5 0.65/0.5 AC — — V DC Rated power DC/sensitive DC Operating range DC/sensitive DC (0.73…1.5)UN/(0.73…1.5)UN (0.73...1.5)UN/(0.8…1.5)UN Holding voltage DC 0.4 UN 0.4 UN Must drop-out voltage DC 0.1 UN 0.1 UN Technical data Mechanical life cycles 10 · 106 10 · 106 Electrical life at rated load AC1 cycles 200 · 103 100 · 103 7/3 (10/3 sensitive) 7/3 (10/3 sensitive) Insulation between coil and contacts (1.2/50 μs) kV 6 (8 mm) 6 (8 mm) Dielectric strength between open contacts V AC 1,000 1,000 –40…+85 –40…+85 RT II** RT II** VI-2014, www.findernet.com Operate/release time Ambient temperature range Environmental protection ms °C Approvals (according to type) ** See general technical information “Guidelines for automatic flow solder processes” page II. 3 40 SERIES 40 Series - Miniature PCB/Plug-in relays 8 - 10 - 12 - 16 A Features 1 Pole relay range - 1 Pole 10 A (Flat pack) DC coils Cadmium Free option available • 8 mm, 6 kV (1.2/50 μs) isolation, coil-contacts • • 1 Pole 10 A Flat pack • PCB mount • • FOR UL RATINGS SEE: “General technical information” page V Copper side view Pin length 3.5 mm for PCB only For outline drawing see page 10 Contact specification 1 CO (SPDT) Contact configuration Rated current/Maximum peak current A Rated voltage/Maximum switching voltage V AC 10/20 250/400 Rated load AC1 VA 2,500 Rated load AC15 (230 V AC) VA 500 Single phase motor rating (230 V AC) kW Breaking capacity DC1: 30/110/220 V Minimum switching load A mW (V/mA) 0.37 10/0.3/0.12 300 (5/5) AgCdO Standard contact material Coil specification Nominal voltage (UN) V AC (50/60 Hz) V DC Rated power AC/DC/sens. DC VA (50 Hz)/W/W Operating range AC DC/sens. DC — 6 - 12 - 24 - 48 - 60 —/—/0.5 — —/(0.73…1.75)UN Holding voltage AC/DC —/0.4 UN Must drop-out voltage AC/DC —/0.1 UN Technical data Mechanical life cycles 20 · 106 Electrical life at rated load AC1 cycles 200 · 103 Operate/release time ms 12/4 Insulation between coil and contacts (1.2/50 μs) kV 6 (8 mm) Dielectric strength between open contacts V AC 1,000 Ambient temperature range Environmental protection Approvals (according to type) 4 °C –40…+70 RT I VI-2014, www.findernet.com A 40.11 40 SERIES 40 Series - Miniature PCB/Plug-in relays 8 - 10 - 12 - 16 A Ordering information Example: 40 series PCB relay, 2 CO (DPDT), 230 V AC coil. A 4 0 . 5 2 . 8 . 2 3 0 . 0 B C D 0 0 0 A: Contact material See table below Series Type 1 = PCB - 3.5 mm pinning, flat 3 = PCB/Plug-in - 3.5 mm pinning 5 = PCB/Plug-in - 5 mm pinning 6 = PCB/Plug-in - 5 mm pinning B: Contact circuit 0 = CO (nPDT) 3 = NO (nPST) No. of poles 1 = 1 pole 2 = 2 pole A D: Special versions 0 = Standard 1 = Wash tight (RT III) 3 = High temperature (+ 125 °C) wash tight C: Options 0 = Pins length 5.3 mm (Plug-in relays) 2 = Pins length 3.5 mm (PCB relays) Coil version 6 = AC/DC bistable 7 = Sensitive DC, 0.5 W 8 = AC (50/60 Hz) 9 = Standard DC, 0.65 W Coil voltage See coil specifications Selecting features and options: only combinations in the same row are possible. Preferred selections for best availability are shown in bold. Terminal pin Type Coil version A B C D PCB relay, 40.11 Sensitive DC 2 (AgCdO) - 4 (AgSnO2) 0 0 0 pin length 3.5 mm 40.31* Standard DC/sensitive DC 1 (AgNi) 0-3 2 0-1 40.61* Standard DC/sensitive DC 1 (AgNi) - 2 (AgCdO) 0-3 2 0-1 PCB/Plug-in relay, 40.31*/51 AC/sensitive DC 0 (AgNi) - 2 (AgCdO) - 5 (AgNi+Au) 0-3 0 0-1 pin length 5.3 mm 40.31*/51 Standard DC 0 (AgNi) - 2 (AgCdO) - 5 (AgNi+Au) 0-3 0 0-1-3 40.52 AC/sensitive DC 0 (AgNi) - 2 (AgCdO) - 5 (AgNi+Au) 0-3 0 0-1 40.52 Standard DC 0 (AgNi) - 2 (AgCdO) - 5 (AgNi+Au) 0-3 0 0-1-3 40.61* AC/sensitive DC 0 (AgCdO) - 4 (AgSnO2) 0-3 0 0-1 40.61* Standard DC 0 (AgCdO) - 4 (AgSnO2) 0-3 0 0-1-3 40.31/51/52 Bistable 0 (AgNi) 0 0 0 40.61 0 (AgCdO) 0 0 0 40.31 1 pole 10 A 40.31 New 1 pole 12 A 3.5 mm pin pitch For socket** or pcb mount pin length 5.3 mm Bistable 40.61 1 pole 16 A 40.61 New 1 pole 16 A 5 mm pin pitch For socket or pcb mount pin length 5.3 mm VI-2014, www.findernet.com * As the result of new production lines and increased production capacity, the design/specification of the DC versions with standard contact material is being changed to align with PCB relay versions 40.x1...20. For full technical data refer to page 3. ** For 40.31 relays mounted on sockets, the maximum rated current must be limited to 10 A. 5 40 SERIES 40 Series - Miniature PCB/Plug-in relays 8 - 10 - 12 - 16 A Technical data Insulation according to EN 61810-1 1 pole 2 pole Nominal voltage of supply system V AC 230/400 Rated insulation voltage V AC 250 400 250 400 3 2 3 2 Pollution degree 230/400 Insulation between coil and contact set Type of insulation Overvoltage category Rated impulse voltage kV (1.2/50 μs) Dielectric strength V AC Reinforced (8 mm) Reinforced (8 mm) III III 6 6 4,000 4,000 Insulation between adjacent contacts Type of insulation — Basic Overvoltage category — II kV (1.2/50 μs) — 2.5 V AC — 2,000 Rated impulse voltage Dielectric strength Insulation between open contacts Type of disconnection Micro-disconnection Micro-disconnection 1,000/1.5 1,000/1.5 Burst (5...50)ns, 5 kHz, on A1 - A2 EN 61000-4-4 level 4 (4 kV) Surge (1.2/50 μs) on A1 - A2 (differential mode) EN 61000-4-5 level 3 (2 kV) Dielectric strength V AC/kV (1.2/50 μs) Conducted disturbance immunity Other data Bounce time: NO/NC ms 2/5 Vibration resistance (10...150)Hz: NO/NC g 20/5 (1 changeover) 14/2 (2 changeover) Shock resistance NO/NC g 20/13 (1 changeover) 20/12 (2 changeover) Power lost to the environment without contact current W 0.65 with rated current W 1.2 (40.11/31/51) Recommended distance between relays mounted on PCB mm 2 (40.61/52) ≥ 5 VI-2014, www.findernet.com A 6 40 Series - Miniature PCB/Plug-in relays 8 - 10 - 12 - 16 A 40 SERIES Contact specification F 40 - Electrical life (AC) v contact current Type 40.52 Resistive load - cosϕ = 1 Inductive load - cosϕ = 0.4 Cycles Cycles F 40 - Electrical life (AC) v contact current Types 40.31/51/61 A Resistive load - cosϕ = 1 Inductive load - cosϕ = 0.4 limit for 40.31/51 **Inductive load - AC15 *limit for 40.31 * limit for 40.31, see page 3 ** Inductive load - AC15 for 40.31/61, see page 3 Cycles Resistive load - cosϕ = 1 Inductive load - cosϕ = 0.4 H 40 - Maximum DC1 breaking capacity DC breaking current (A) F 40 - Electrical life (AC) v contact current Type 40.11 40.61 current limit 40.11/31/51 current limit 40.52 current limit 40.52 - 2 contacts in series single contact DC voltage (V) VI-2014, www.findernet.com • When switching a resistive load (DC1) having voltage and current values under the curve, an electrical life of ≥ 100·103 can be expected. • In the case of DC13 loads, the connection of a diode in parallel with the load will permit a similar electrical life as for a DC1 load. Note: the release time for the load will be increased. 7 40 SERIES 40 Series - Miniature PCB/Plug-in relays 8 - 10 - 12 - 16 A Coil specifications DC coil data - 0.65 W standard (types 40.31/51/52/61) A Nominal voltage UN V 5 6 7 9 12 14 18 21 24 28 36 48 60 90 110 125 Coil code 9.005 9.006 9.007 9.009 9.012 9.014 9.018 9.021 9.024 9.028 9.036 9.048 9.060 9.090 9.110 9.125 Operating range Umin V 3.65 4.4 5.1 6.6 8.8 10.2 13.1 15.3 17.5 20.5 26.3 35 43.8 65.7 80.3 91.2 Umax V 7.5 9 10.5 13.5 18 21 27 31.5 36 42 54 72 90 135 165 188 Resistance Rated coil consumption R I at UN Ω mA 38 130 55 109 75 94 125 72 220 55 300 47 500 36 700 30 900 27 1,200 23 2,000 18 3,500 14 5,500 11 12,500 7.2 18,000 6.2 23,500 5.3 DC coil data - 0.5 W sensitive (types 40.31/51/52/61) Nominal voltage UN V 5 6 7 9 12 14 18 21 24 28 36 48 60 90 110 125 Coil code Operating range Umin* V 3.7 4.4 5.1 6.6 8.8 10.2 13.2 15.4 17.5 20.5 26.3 35 43.8 65.7 80.3 91.2 7.005 7.006 7.007 7.009 7.012 7.014 7.018 7.021 7.024 7.028 7.036 7.048 7.060 7.090 7.110 7.125 Umax V 7.5 9 10.5 13.5 18 21 27 31.5 36 42 54 72 90 135 165 188 Resistance Rated coil consumption R I at UN Ω mA 50 100 75 80 100 70 160 56 288 42 400 35 650 27.7 900 23.4 1,150 21 1,600 17.5 2,600 13.8 4,800 10 7,200 8.4 16,200 5.6 23,500 4.7 32,000 3.9 *Umin = 0.8 UN for 40.61 DC coil data - 0.5 W sensitive (type 40.11) Nominal voltage UN V 6 12 24 48 60 Coil code 7.006 7.012 7.024 7.048 7.060 Operating range Umin V 4.4 8.8 17.5 35 43.8 Umax V 10.5 21 42 84 105 Resistance Rated coil consumption R I at UN Ω mA 75 80 300 40 1,200 20 4,600 10.4 7,200 8.3 AC/DC coil data - bistable (types 40.31/51/52/61) AC coil data (types 40.31/51/52/61) Coil code 8.006 8.012 8.024 8.048 8.060 8.110 8.120 8.230 8.240 Operating range Umin V 4.8 9.6 19.2 38.4 48 88 96 184 192 Umax V 6.6 13.2 26.4 52.8 66 121 132 253 264 Resistance Rated coil consumption R I at UN (50Hz) Ω mA 21 168 80 90 320 45 1,350 21 2,100 16.8 6,900 9.4 9,000 8.4 28,000 5 31,500 4.1 Nominal voltage UN V 5 6 12 24 48 110 Coil code 6.005 6.006 6.012 6.024 6.048 6.110 Operating range Umin V 4 4.8 9.6 19.2 38.4 88 Umax V 5.5 6.6 13.2 26.4 52.8 121 Resistance Rated coil DC: Release consumption resistance** R I at UN RDC Ω mA Ω 23 215 37 33 165 62 130 83 220 520 40 910 2,100 21 3,600 11,000 10 16,500 ** RDC = Resistance in DC, RAC = 1.3 x RDC 1W VI-2014, www.findernet.com Nominal voltage UN V 6 12 24 48 60 110 120 230 240 8 40 Series - Miniature PCB/Plug-in relays 8 - 10 - 12 - 16 A 40 SERIES Coil specifications R 40 - DC coil operating range v ambient temperature Standard coil R 40 - DC coil operating range v ambient temperature Sensitive coil, types 40.31/51/52/61 A 40.61 40.31/51/52 R 40 - DC coil operating range v ambient temperature Sensitive coil, type 40.11 R 40 - AC coil operating range v ambient temperature 1 - Max. permitted coil voltage. 2 - Min. pick-up voltage with coil at ambient temperature. 1 - Max. permitted coil voltage. 2 - Min. pick-up voltage with coil at ambient temperature. VI-2014, www.findernet.com Wiring diagram for 40 series bistable coil version AC Operation DC Operation On momentary closure of the SET switch the relay is magnetised through the diode and the relay contacts transfer to the set position and remain in this position. On momentary closure of the RESET switch the relay is demagnetised through limiting resistor (RAC) and the contacts return to the reset position. On momentary closure of the SET switch the relay is magnetised and the relay contacts transfer to the set position and remain in this position. On momentary closure of the RESET switch the relay is demagnetised through limiting resistor (RDC) and the contacts return to the reset position. Notes: The minimum SET or RESET impulse time is 20 ms. The maximum time can be continuous. In practice, always ensure that the SET and RESET contacts cannot be operated simultaneously. 9 40 SERIES 40 Series - Miniature PCB/Plug-in relays 8 - 10 - 12 - 16 A Outline drawings Type 40.31/51/52/61 Type 40.31/61 Type 40.11 A VI-2014, www.findernet.com * (3.5 or 5.3) mm see ordering code 10 95 Series - Socket overview for 40 series relays Module Socket 99.02 95.03 95.05 Description Screw terminal (Box clamp) socket - Top terminals - Contacts - Bottom terminals - Coil Mounting Panel or 35 mm rail (EN 60715) mount Accessories - Coil indication and EMC suppression modules - Jumper link - Timer modules - Plastic retaining and release clip Module Socket Relay Description 99.80 95.83.3 40.31 Screw terminal (Box clamp) socket 95.85.3 40.51 95.83.3 wiring: 40.52 - Top terminals - Contacts 40.61 - Bottom terminals - Coil Mounting Panel or 35 mm rail (EN 60715) mount Accessories - Coil indication and EMC suppression modules - Jumper link - Plastic retaining and release clip Module Socket Relay Description 99.80 95.93.3 40.31 Screw terminal (Box clamp) socket 95.95.3 40.51 - Top terminals - Contacts 40.52 - Bottom terminals - Coil 40.61 Mounting Panel or 35 mm rail (EN 60715) mount Accessories - Coil indication and EMC suppression modules - Jumper link - Plastic retaining and release clip Module Socket 99.02 95.55 Description Screwless terminal socket - For fast cable connections - Top terminals - Contacts - Bottom terminals - Coil Mounting Panel or 35 mm rail (EN 60715) mount Accessories - Coil indication and EMC suppression modules - Timer modules - Plastic retaining and release clip Description Screwless terminal socket For fast cable connections - Top terminals - Contacts - Bottom terminals - Coil Mounting Panel or 35 mm rail (EN 60715) mount Accessories - Coil indication and EMC suppression modules - Plastic retaining and release clip Module Socket 99.01 95.63 Relay Description 40.31 Screw terminal (Box clamp) socket - Top terminals - Contacts - Bottom terminals - Coil Mounting Panel or 35 mm rail (EN 60715) mount Accessories - Coil indication and EMC suppression modules - Metal retaining clip Module Socket — 95.65 Relay Description 40.51 Screw terminal (Box clamp) socket 40.52 40.61 Mounting Panel or 35 mm rail (EN 60715) mount Accessories - Metal retaining clip Mounting PCB mounting Accessories - Metal retaining clip - Plastic retaining clip 95.05 Relay 40.31 40.51 40.52 40.61 40 SERIES See page 12 95.85.3 See page 13 95.95.3 See page 14 Relay 40.51 40.52 40.61 95.55 See page 15 Module Socket Relay 99.80 95.55.3 40.51 40.52 40.61 95.55.3 See page 16 95.63 See page 17 95.65 VI-2014, www.findernet.com See page 17 95.13.2 See page 18 Module Socket Relay Description — 95.13.2 40.31 PCB socket — 95.15.2 40.51 40.52 40.61 11 A 40 SERIES Screw terminal (Box clamp) socket panel or 35 mm rail mount For relay type Accessories Metal retaining clip 95.05 Plastic retaining and release clip (supplied with socket - packaging code SPA) Approvals 8-way jumper link (according to type): Identification tag Modules (see table below) Timer modules (see table below) Sheet of marker tags for retaining and release clip 095.01 Certain relay/socket plastic, 72 tags, 6x12 mm combinations Technical data Rated values Dielectric strength Protection category Ambient temperature °C Screw torque Nm 095.01 Wire strip length mm Max. wire size for 95.03 and 95.05 sockets mm2 AWG 95.03 (blue) 40.31 95.03.0 (black) 95.05 (blue) 95.05.0 (black) 40.51, 40.52, 40.61 095.01 095.01.0 095.18 095.18.0 095.18 095.00.4 99.02 86.30 060.72 095.71 095.01 095.01.0 095.18.0 10 A - 250 V * 6 kV (1.2/50 μs) between coil and contacts IP 20 –40…+70 (see diagram L95) 0.5 8 solid wire stranded wire 1x6 / 2x2.5 1x4 / 2x2.5 1x10 / 2x14 1x12 / 2x14 * For currents >10 A, contact terminals must be connected in parallel (21 with 11, 24 with 14, 22 with 12). With the relay 40.51 the change-over contact will be 21-12-14. 060.72 L 95 - Total socket current vs ambient temperature (95.05) Total socket current (A) 11 A2 COM 14 NO 12 NC A1 COIL O P A PEAN N T E T EUR EUR 95.03 O PEAN 95.05 8-way jumper link for 95.03 and 95.05 sockets 095.18 (blue) Rated values 10 A - 250 V 095.18.0 (black) 095.18 86 series timer modules 86.30 99.02 Approvals (according to type): DC Modules with non-standard polarity (+A2) on request. 12 (12…24)V AC/DC; Bi-function: AI, DI; (0.05s…100h) 86.30.0.024.0000 (110...125)V AC; Bi-function: AI, DI; (0.05s…100h) 86.30.8.120.0000 (230...240)V AC; Bi-function: AI, DI; (0.05s…100h) 86.30.8.240.0000 Approvals (according to type): 99.02 coil indication and EMC suppression modules for 95.03 and 95.05 sockets Diode (+A1, standard polarity) (6...220)V DC 99.02.3.000.00 LED (6...24)V DC/AC 99.02.0.024.59 LED (28...60)V DC/AC 99.02.0.060.59 LED (110...240)V DC/AC 99.02.0.230.59 LED + Diode (+A1, standard polarity) (6...24)V DC 99.02.9.024.99 LED + Diode (+A1, standard polarity) (28...60)V DC 99.02.9.060.99 LED + Diode (+A1, standard polarity) (110...220)V DC 99.02.9.220.99 LED + Varistor (6...24)V DC/AC 99.02.0.024.98 LED + Varistor (28...60)V DC/AC 99.02.0.060.98 LED + Varistor (110...240)V DC/AC 99.02.0.230.98 RC circuit (6...24)V DC/AC 99.02.0.024.09 RC circuit (28...60)V DC/AC 99.02.0.060.09 RC circuit (110...240)V DC/AC 99.02.0.230.09 Residual current by-pass (110...240)V AC 99.02.8.230.07 VI-2014, www.findernet.com A 95 Series - Sockets and accessories for 40 series relays 40 SERIES 95 Series - Sockets and accessories for 40 series relays Screw terminal (Box clamp) socket panel or 35 mm rail mount For relay type Accessories Metal retaining clip Plastic retaining and release clip (supplied with socket - packaging code SPA) 8-way jumper link Identification tag Modules (see table below) Sheet of marker tags for retaining and release clip 095.91.3 plastic, 72 tags, 6x12 mm Technical data Rated values Dielectric strength Protection category Ambient temperature °C Screw torque Nm Wire strip length mm Max. wire size for 95.83.3 and 95.85.3 sockets m2 AWG 95.85.3 Approvals (according to type): 095.91.3 95.83.3 (blue) 40.31 95.83.30 (black) 95.85.3 (blue) 95.85.30 (black) 40.51, 40.52, 40.61 095.91.3 095.71 095.91.30 095.91.3 095.08 095.08.0 095.08 095.80.3 99.80 060.72 095.91.30 095.08.0 10 A - 250 V * 6 kV (1.2/50 μs) between coil and contacts (95.83.3 only) IP 20 –40…+70 (see diagram L95) 0.5 7 solid wire stranded wire 1x6 / 2x2.5 1x4 / 2x2.5 1x10 / 2x14 1x12 / 2x14 * For currents >10 A, contact terminals must be connected in parallel (21 with 11, 24 with 14, 22 with 12). With the relay 40.51 the change-over contact will be 21-12-14. 060.72 Total socket current (A) L 95 - Total socket current vs ambient temperature (95.85.3) P A PEAN N T E O O T EUR EUR 95.83.3 95.85.3 8-way jumper link for 95.83.3 and 95.85.3 sockets 095.08 (blue) Rated values 10 A - 250 V 095.08.0 (black) PEAN 095.08 99.80 coil indication and EMC suppression modules for 95.83.3 and 95.85.3 sockets Blue* Diode (+A1, standard polarity) LED 99.80 VI-2014, www.findernet.com Approvals (according to type): (6...220)V DC 99.80.3.000.00 (6...24)V DC/AC 99.80.0.024.59 LED (28...60)V DC/AC 99.80.0.060.59 LED (110...240)V DC/AC 99.80.0.230.59 LED + Diode (+A1, standard polarity) (6...24)V DC 99.80.9.024.99 LED + Diode (+A1, standard polarity) (28...60)V DC 99.80.9.060.99 LED + Diode (+A1, standard polarity) (110...220)V DC 99.80.9.220.99 LED + Varistor (6...24)V DC/AC 99.80.0.024.98 * Modules in Black housing are available on request. LED + Varistor (28...60)V DC/AC 99.80.0.060.98 LED + Varistor (110...240)V DC/AC 99.80.0.230.98 (6...24)V DC/AC 99.80.0.024.09 Green LED is standard. Red LED available on request. RC circuit (28...60)V DC/AC 99.80.0.060.09 RC circuit (110...240)V DC/AC 99.80.0.230.09 (110...240)V AC 99.80.8.230.07 RC circuit Residual current by-pass 13 A 40 SERIES 95 Series - Sockets and accessories for 40 series relays Screw (Box clamp) terminal socket panel or 35 mm rail mount For relay type Accessories Metal retaining clip Plastic retaining and release clip 8-way jumper link Identification tag Modules (see table below) Sheet of marker tags for retaining and release clip 095.91.3 plastic, 72 tags, 6x12 mm Technical data Rated values Dielectric strength Protection category Ambient temperature °C Screw torque Nm Wire strip length mm Max. wire size for 95.93.3 and 95.95.3 sockets m2 AWG A 95.95.3 Approvals (according to type): 095.91.3 95.93.3 (blue) 40.31 95.93.30 (black) 95.95.3 (blue) 95.95.30 (black) 40.51, 40.52, 40.61 095.71 095.91.30 095.91.3 095.08.0 095.08 095.80.3 99.80 060.72 095.91.3 095.08 095.91.30 095.08.0 10 A - 250 V * 6 kV (1.2/50 μs) between coil and contacts IP 20 –40…+70 (see diagram L95) 0.5 8 solid wire stranded wire 1x6 / 2x2.5 1x4 / 2x2.5 1x10 / 2x14 1x12 / 2x14 * For currents >10 A, contact terminals must be connected in parallel (21 with 11, 24 with 14, 22 with 12). With the relay 40.51 the change-over contact will be 21-12-14. 060.72 Total socket current (A) L 95 - Total socket current vs ambient temperature (95.95.3) P A PEAN N T E O O T EUR EUR 95.93.3 95.95.3 8-way jumper link for 95.93.3 and 95.95.3 sockets 095.08 (blue) Rated values 10 A - 250 V 095.08.0 (black) PEAN 095.08 99.80 coil indication and EMC suppression modules for 95.93.3 and 95.95.3 sockets LED 99.80 Approvals (according to type): (6...220)V DC 99.80.3.000.00 (6...24)V DC/AC 99.80.0.024.59 LED (28...60)V DC/AC 99.80.0.060.59 LED (110...240)V DC/AC 99.80.0.230.59 LED + Diode (+A1, standard polarity) (6...24)V DC 99.80.9.024.99 LED + Diode (+A1, standard polarity) (28...60)V DC 99.80.9.060.99 LED + Diode (+A1, standard polarity) (110...220)V DC 99.80.9.220.99 LED + Varistor (6...24)V DC/AC 99.80.0.024.98 * Modules in Black housing are available on request. LED + Varistor (28...60)V DC/AC 99.80.0.060.98 LED + Varistor (110...240)V DC/AC 99.80.0.230.98 (6...24)V DC/AC 99.80.0.024.09 Green LED is standard. Red LED available on request. RC circuit (28...60)V DC/AC 99.80.0.060.09 RC circuit (110...240)V DC/AC 99.80.0.230.09 (110...240)V AC 99.80.8.230.07 14 RC circuit Residual current by-pass VI-2014, www.findernet.com Blue* Diode (+A1, standard polarity) 95 Series - Sockets and accessories for 40 series relays 95.55 Approvals (according to type): 095.91.3 Screwless terminal socket panel or 35 mm rail mount For relay type Accessories Metal retaining clip Plastic retaining and release clip (supplied with socket - packaging code SPA) Modules (see table below) Timer modules (see table below) Sheet of marker tags for retaining and release clip 095.91.3 plastic, 72 tags, 6x12 mm Technical data Rated values Dielectric strength Protection category Ambient temperature °C Wire strip length mm Max. wire size for 95.55 socket mm2 AWG 95.55 (blue) 40.51, 40.52, 40.61 40 SERIES 95.55.0 (black) A 095.71 095.91.3 99.02 86.30 060.72 10 A - 250 V * 6 kV (1.2/50 μs) between coil and contacts IP 20 –25…+70 (see diagram L95) 8 solid wire stranded wire 2x(0.2...1.5) 2x(0.2...1.5) 2x(24...18) 2x(24...18) * For currents >10 A, contact terminals must be connected in parallel (21 with 11, 24 with 14, 22 with 12). With the relay 40.51 the change-over contact will be 21-12-14. 060.72 Total socket current (A) L 95 - Total socket current vs ambient temperature 86 series timer modules 86.30 99.02 VI-2014, www.findernet.com Approvals (according to type): DC Modules with non-standard polarity (+A2) on request. (12…24)V AC/DC; Bi-function: AI, DI; (0.05s…100h) 86.30.0.024.0000 (110...125)V AC; Bi-function: AI, DI; (0.05s…100h) 86.30.8.120.0000 (230...240)V AC; Bi-function: AI, DI; (0.05s…100h) 86.30.8.240.0000 Approvals (according to type): 99.02 coil indication and EMC suppression modules for 95.55 socket Diode (+A1, standard polarity) (6...220)V DC LED (6...24)V DC/AC LED (28...60)V DC/AC LED (110...240)V DC/AC LED + Diode (+A1, standard polarity) (6...24)V DC LED + Diode (+A1, standard polarity) (28...60)V DC LED + Diode (+A1, standard polarity) (110...220)V DC LED + Varistor (6...24)V DC/AC LED + Varistor (28...60)V DC/AC LED + Varistor (110...240)V DC/AC RC circuit (6...24)V DC/AC RC circuit (28...60)V DC/AC RC circuit (110...240)V DC/AC Residual current by-pass (110...240)V AC 99.02.3.000.00 99.02.0.024.59 99.02.0.060.59 99.02.0.230.59 99.02.9.024.99 99.02.9.060.99 99.02.9.220.99 99.02.0.024.98 99.02.0.060.98 99.02.0.230.98 99.02.0.024.09 99.02.0.060.09 99.02.0.230.09 99.02.8.230.07 15 40 SERIES 95 Series - Sockets and accessories for 40 series relays A 95.55.3 Approvals (according to type): 095.91.3 Screwless terminal socket panel or 35 mm rail mount For relay type Accessories Metal retaining clip Plastic retaining and release clip (supplied with socket - packaging code SPA) Modules (see table below) Sheet of marker tags for retaining and release clip 095.91.3 plastic, 72 tags, 6x12 mm Technical data Rated values Dielectric strength Protection category Ambient temperature °C Wire strip length mm Max. wire size for 95.55.3 socket mm2 AWG 95.55.3 (blue) 40.51, 40.52, 40.61 95.55.30 (black) 095.71 095.91.3 99.80 060.72 10 A - 250 V * 6 kV (1.2/50 μs) between coil and contacts IP 20 –25…+70 (see diagram L95) 8 solid wire stranded wire 2x(0.2...1.5) 2x(0.2...1.5) 2x(24...18) 2x(24...18) * For currents >10 A, contact terminals must be connected in parallel (21 with 11, 24 with 14, 22 with 12). With the relay 40.51 the change-over contact will be 21-12-14. 73.7 24.6 060.72 21 COM 11 24 NO 14 22 NC 12 37. 2 A2 COIL 34.7 Ø 3.2 30.3 95. 6 Total socket current (A) 30. 6 L 95 - Total socket current vs ambient temperature 4 4 A1 15.8 22.6 32.5 99.80 coil indication and EMC suppression modules for 95.55.3 socket Blue* Diode (+A1, standard polarity) 99.80 Approvals (according to type): (6...220)V DC 99.80.3.000.00 LED (6...24)V DC/AC 99.80.0.024.59 LED (28...60)V DC/AC 99.80.0.060.59 LED (110...240)V DC/AC 99.80.0.230.59 LED + Diode (+A1, standard polarity) (6...24)V DC 99.80.9.024.99 LED + Diode (+A1, standard polarity) (28...60)V DC 99.80.9.060.99 LED + Diode (+A1, standard polarity) (110...220)V DC 99.80.9.220.99 LED + Varistor (6...24)V DC/AC 99.80.0.024.98 * Modules in Black housing are available on request. LED + Varistor (28...60)V DC/AC 99.80.0.060.98 LED + Varistor (110...240)V DC/AC 99.80.0.230.98 (6...24)V DC/AC 99.80.0.024.09 Green LED is standard. Red LED available on request. RC circuit (28...60)V DC/AC 99.80.0.060.09 RC circuit (110...240)V DC/AC 99.80.0.230.09 (110...240)V AC 99.80.8.230.07 RC circuit VI-2014, www.findernet.com Residual current by-pass 16 95 Series - Sockets and accessories for 40 series relays Screw terminal (Box clamp) socket panel or 35 mm rail mount For relay type Accessories Metal retaining clip 8-way jumper link Modules (see table below) Technical data Rated values Dielectric strength (between coil and contacts) Protection category Ambient temperature °C Screw torque Nm Wire strip length mm Max. wire size for 95.63 and 95.65 sockets m2 AWG 95.63 Approvals (according to type): 95.65 Approvals (according to type): 95.63 (blue) 40.31 40 SERIES 95.65 (blue) 40.51, 40.52, 40.61 A 095.71 095.08 — 095.08 99.01 10 A - 250 V * 6 kV (1.2/50 μs) 2 kV AC IP 20 –40…+70 (see diagram L95) 0.5 7 solid wire stranded wire 1x6 / 2x2.5 1x4 / 2x2.5 1x10 / 2x14 1x12 / 2x14 * For currents >10 A, contact terminals must be connected in parallel (21 with 11, 24 with 14, 22 with 12). With the relay 40.51 the change-over contact will be 21-12-14. Total socket current (A) L 95 - Total socket current vs ambient temperature P A PEAN N T E O O T EUR EUR 95.63 95.65 8-way jumper link for 95.63 and 95.65 sockets 095.08 (blue) Rated values 10 A - 250 V PEAN 095.08 99.01 coil indication and EMC suppression modules for type 95.63 socket VI-2014, www.findernet.com Blue* Diode (+A1, standard polarity) (6...220)V DC 99.01.3.000.00 Diode (+A2, non-standard polarity) (6...220)V DC 99.01.2.000.00 99.01 LED (6...24)V DC/AC 99.01.0.024.59 Approvals (according to type): LED (28...60)V DC/AC 99.01.0.060.59 LED (110...240)V DC/AC 99.01.0.230.59 LED + Diode (+A1, standard polarity) (6...24)V DC 99.01.9.024.99 LED + Diode (+A1, standard polarity) (28...60)V DC 99.01.9.060.99 LED + Diode (+A1, standard polarity) (110...220)V DC 99.01.9.220.99 LED + Diode (+A2, non-standard polarity) (6...24)V DC 99.01.9.024.79 LED + Diode (+A2, non-standard polarity) (28...60)V DC 99.01.9.060.79 LED + Diode (+A2, non-standard polarity) (110...220)V DC 99.01.9.220.79 LED + Varistor (6...24)V DC/AC 99.01.0.024.98 99.01.0.060.98 * Modules in Black housing are available on request. LED + Varistor (28...60)V DC/AC LED + Varistor (110...240)V DC/AC 99.01.0.230.98 (6...24)V DC/AC 99.01.0.024.09 Green LED is standard. Red LED available on request. RC circuit (28...60)V DC/AC 99.01.0.060.09 RC circuit (110...240)V DC/AC 99.01.0.230.09 (110...240)V AC 99.01.8.230.07 RC circuit Residual current by-pass 17 40 SERIES PCB socket For relay type Accessories Metal retaining clip (supplied with socket - packaging code SMA) Plastic retaining clip Technical data Rated values Dielectric strength Protection category Ambient temperature °C 95.13.2 95.15.2 Approvals (according to type): 95.13.2 (blue) 40.31 95.13.20 (black) 95.15.2 (blue) 95.15.20 (black) 40.51, 40.52, 40.61 095.51 095.52 12 A - 250 V 10 A - 250 V * 6 kV (1.2/50 μs) between coil and contacts IP 20 –40…+70 * For currents >10 A, contact terminals must be connected in parallel (21 with 11, 24 with 14, 22 with 12). With the relay 40.51 the change-over contact will be 21-12-14. 40.31 40.51 3.5 13 7.5 A1 12 11 14 A2 22 21 24 12 14 22 24 11 1.5 3.5 30 20 95.13.2 40.52 A1 21 A2 95.15.2 Copper side view Copper side view 40.61 Packaging codes How to code and identify retaining clip and packaging options for sockets. Example: 9 5 . 0 5 S P A A Standard packaging SM Metal retaining clip SP Plastic retaining clip 9 5 . 0 18 5 Without retaining clip VI-2014, www.findernet.com A 95 Series - Sockets and accessories for 40 series relays
95.95.3 价格&库存

很抱歉,暂时无法提供与“95.95.3”相匹配的价格&库存,您可以联系我们找货

免费人工找货