0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
18.01.8.230.0000

18.01.8.230.0000

  • 厂商:

    FINDER

  • 封装:

  • 描述:

    PIR MOTION DETECTOR INTERNAL

  • 数据手册
  • 价格&库存
18.01.8.230.0000 数据手册
PIR movement and presence detectors 10 A Hotel room energy-enabling units Lighting control in corridors (for hotels, offices and hospitals) Offices, swimming baths and schools Staircase light control 18 SЕRIES FINDER reserves the right to alter characteristics at any time without notice. FINDER assumes no liability for damage to persons or property, caused as a result of the incorrect use or application of its products. 18 SERIES PIR movement detectors 10 A 18 SERIES 18.01 PIR movement detectors for internal or external installations - wall mounting 18.11 18.A1 Type 18.01 --Internal installation --Surface mounting Type 18.11 --External installation (IP54) --Surface mounting Type 18.A1 --External mounting (IP55) --Terminal for PE connection --Push-in terminals • Output contact connected to supply live • 1 NO 10 A • Small size • Internal installations • Adjustable ambient light intervention threshold • Adjustable Light ON Time • Universal mounting position - permits the • 1 NO 10 A • External installations • Protection category IP 54 selection of any area for survey • 1 NO 10 A • External installations • Protection category IP 55 • PE terminal • Push-in terminals • Wide angle of survey 18.01/18.11 Screw terminal 18.A1 Push-in terminal NOTE: with 110…125 V AC supply, the Ratings (AC1, AC15 and lamp loads) must be reduced by 50 % (e.g. 500 W instead of 1000 W) For outline drawings see page 17 Contact specification Number of contacts 1 NO (SPST-NO) 1 NO (SPST-NO) 1 NO (SPST-NO) 10/20 (100 A - 5 ms) 10/20 (100 A - 5 ms) 10/20 (100 A - 5 ms) 230/230 2300 230/230 2300 230/230 2300 (230 V) VA 450 450 450 incandescent/halogen W fluorescent lamp with electronic ballast W fluorescent lamp with electromecanical ballast W CFL W 1000 1000 1000 500 500 500 350 300 350 300 350 300 LED 230 V W halogen or LV LED with electronic ballast W halogen or LV LED with electromechanical ballast W Standard contact material 300 300 300 300 300 300 500 AgSnO2 500 AgSnO2 500 AgSnO2 120…230 120…230 110…230 — — — Rated current/Maximum peak current Rated voltage/ Maximum switching voltage Rated load AC1 Rated load AC15 A V AC VA Nominal lamp rating 230 V: J Supply specification Coil specification V AC (50/60 Hz) DC Rated power AC/DC Operating range VA (50 Hz)/W V AC (50/60 Hz) DC 2.5/— 2.5/— 2/0.8 96…253 96…253 96…253 — — — 100 · 103 100 · 103 100 · 103 Technical data Electrical life at rated load AC1 X-2017, www.findernet.com Ambient light intervention threshold cycles lx Light ON time after last detection Sensing area diameter Ambient temperature range Protection category °C 5…350 5…350 5…1000 10 s…12 min 10 s…12 min 10 s…20 min See diagram page 15 See diagram page 15 See diagram page 15 –10…+50 –30…+50 –30…+50 IP 40 IP 54 IP 55 Approvals (according to type) 3 18 SERIES 18 SERIES PIR movement detectors 10 A 18.21 PIR movement detectors for internal installations - ceiling mount 18.31 18.31-0031 Type 18.21 --Surface mounting Type 18.31 --Recess mounting Type 18.31-0031 --High ceiling type (6 meter max.) --Surface or recess mounting • Output contact connected to supply live • Small size • Adjustable ambient light intervention threshold • 1 NO 10 A • Surface mounting • Adjustable Light ON Time • Wide angle of survey • 1 NO 10 A • Recess mounting • 1 NO 10 A • High ceiling applications (up to 6 meters) • Light ON time after last detection (30 s…35 min) 18.21/18.31/18.31…0031 Screw terminal NOTE: with 110…125 V AC supply, the Ratings (AC1, AC15 and lamp loads) must be reduced by 50 % (e.g. 500 W instead of 1000 W) For outline drawings see page 16 Contact specification Number of contacts 1 NO (SPST-NO) 1 NO (SPST-NO) 1 NO (SPST-NO) 10/20 (100 A - 5 ms) 10/20 (100 A - 5 ms) 10/20 (100 A - 5 ms) 230/230 2300 230/230 2300 230/230 2300 (230 V) VA 450 450 450 incandescent/halogen W fluorescent lamp with electronic ballast W fluorescent lamp with electromecanical ballast W CFL W 1000 1000 1000 500 500 500 350 300 350 300 350 300 LED 230 V W halogen or LV LED with electronic ballast W halogen or LV LED with electromechanical ballast W Standard contact material 300 300 300 300 300 300 500 AgSnO2 500 AgSnO2 500 AgSnO2 120…230 120…230 120…230 — — — Rated current/Maximum peak current Rated voltage/ Maximum switching voltage Rated load AC1 Rated load AC15 A V AC VA Nominal lamp rating 230 V: Supply specification Coil specification V AC (50/60 Hz) DC Rated power AC/DC Operating range VA (50 Hz)/W 2/1 2/1 2/1 96…253 96…253 96…253 — — — cycles 100 · 103 100 · 103 100 · 103 lx 5…350 5…350 5…350 V AC (50/60 Hz) DC Technical data Electrical life at rated load AC1 Ambient light intervention threshold Light ON time after last detection Sensing area diameter Ambient temperature range Protection category Approvals (according to type) 4 °C 10 s…12 min 10 s…12 min 30 s…35 min See diagram page 15 See diagram page 15 See diagram page 15 –10…+50 –10…+50 –10…+50 IP 40 IP 40 IP 40 X-2017, www.findernet.com J 18 SERIES PIR movement detectors 10 A 18 SERIES 18.21-0300 PIR movement detectors for internal installations, with volt-free output contact 18.31-0300 Type 18.21-0300 --Surface mounting Type 18.31-0300 --Recess mounting • Applications where interface to PLC or BMS is required • Ceiling mounting • Small size • Adjustable ambient light intervention threshold • 1 NO 10 A • Adjustable Light ON Time • Surface mounting • Wide angle of survey • 1 NO 10 A • Recess mounting 18.21…0300/18.31…0300 Screw terminal NOTE: with 110…125 V AC supply, the Ratings (AC1, AC15 and lamp loads) must be reduced by 50 % (e.g. 500 W instead of 1000 W) For outline drawings see page 16 Contact specification Number of contacts 1 NO (SPST-NO) 1 NO (SPST-NO) 10/20 (100 A - 5 ms) 10/20 (100 A - 5 ms) 250/400 250/400 VA 2500 2500 (230 V) VA 450 450 1000 1000 500 500 350 350 CFL W 300 300 LED 230 V W 300 300 300 300 500 500 AgSnO2 AgSnO2 120…230 120…230 Rated current/Maximum peak current Rated voltage/ Maximum switching voltage A V AC Rated load AC1 Rated load AC15 Nominal lamp rating 230 V: incandescent/halogen W fluorescent lamp with electronic ballast W fluorescent lamp with electromecanical ballast W halogen or LV LED with electronic ballast W halogen or LV LED with electromechanical ballast W Standard contact material J Supply specification Coil specification V AC (50/60 Hz) V AC (50/60 Hz)/DC 24 24 VA (50 Hz)/W 2/1 2/1 Rated power AC/DC Operating range V AC (50/60 Hz) V AC (50/60 Hz)/DC 96…253 96…253 19.2…26.4 19.2…26.4 100 · 103 100 · 103 Technical data Electrical life at rated load AC1 X-2017, www.findernet.com Ambient light intervention threshold cycles lx Light ON time after last detection Sensing area diameter Ambient temperature range Protection category °C 5…350 5…350 10 s…12 min 10 s…12 min See diagram page 15 See diagram page 15 –10…+50 –10…+50 IP 40 IP 40 Approvals (according to type) 5 18 SERIES 18 SERIES PIR movement and presence detectors 10 A Movement and presence detectors with Push-in terminals For internal installation Type 18.51 --Standard version --Volt-free output contact Type 18.51-0040 --Possibility to connect external push-button to force the output state --Dynamic light compensation --Output contact connected to supply live Type 18.51-B300 --Programmable via Bluetooth LE (Low Energy) using Android and iOS smartphones • Extensive sensing area up to 64 m2 • Two sensing areas: “presence” suitable for zones of low activity, and “movement” suitable for transit areas or zones of high activity • Modern design • Quick installation thanks to push-in terminals • 1 NO contact 10 A, with “zero crossing” switching • Wall mounting compatible with 60 mm box and 2 or 3 module box • Double terminals for easy “looping” in and out 18.51 • 1 NO 10 A (volt-free) • Sensing area 360° 18.51…0040 • 1 NO 10 A (connected to supply live) • Sensing area 360° • External push-button connection • Dynamic Light Compensation 18.51…B300 • 1 NO 10 A (volt-free) • Sensing area 360° 18.51/18.51…0040/18.51…B300 Push-in terminal NOTE: with 110…125 V AC supply, the Ratings (AC1, AC15 and lamp loads) must be reduced by 50 % (e.g. 500 W instead of 1000 W) J Contact specification Number of contacts Rated current/Maximum peak current A Rated voltage/ Maximum switching voltage V AC Rated load AC1 VA Rated load AC15 (230 V) VA Nominal lamp rating 230 V: incandescent/halogen W fluorescent lamp with electronic ballast W fluorescent lamp with electromecanical ballast W CFL W LED 230 V W halogen or LV LED with electronic ballast W halogen or LV LED with electromechanical ballast W Standard contact material Supply specification Coil specification V AC (50/60 Hz) Rated power VA (50 Hz)/W Operating range V AC (50/60 Hz) Technical data Electrical life at rated load AC1 cycles Ambient light intervention threshold lx Light ON time after last detection Sensing area diameter Ambient temperature range °C Protection category Approvals (according to type) 6 1 NO (SPST-NO) 10/20 (100 A - 5 ms) 1 NO (SPST-NO) 10/20 (100 A - 5 ms) 1 NO (SPST-NO) 10/20 (100 A - 5 ms) 250/400 2500 450 230/230 2300 450 230/230 2300 450 1000 1000 1000 500 500 500 350 300 300 350 300 300 350 300 300 300 300 300 500 AgSnO2 500 AgSnO2 500 AgSnO2 110…230 1.5/1 96…253 110…230 1.5/1 96…253 110…230 1.5/1 96…253 100 · 103 1…500 12 s…35 min See diagram page 15 –10…+50 IP 40 100 · 103 1…500 12 s…35 min See diagram page 15 –10…+50 IP 40 100 · 103 4…1000 12 s…25 min See diagram page 15 –10…+50 IP 40 X-2017, www.findernet.com For outline drawings see page 16 18 SERIES PIR movement and presence detectors DALI and KNX Movement and presence detectors with Push-in terminals. For internal installation. 18 SERIES 18.5D 18.5K • Applications: offices, schools, • Applications: offices, schools, Type 18.5D with DALI interface Three selectable functions: --Daylight-linked constant light level control --ON/OFF control with early warning --ON/OFF control with early warning + courtesy light level Type 18.5K with KNX interface --2 outputs (data telegrams) for load control (Lighting, HVAC etc.) --1 output (data telegram) – movement/ presence detected --Adjustment of ambient light threshold, and PIR sensitivity --Master/Slave mode for increased sensing area --Selectable function to inhibit ambient light threshold control --Reporting of light level and movement status (for security purposes, etc.) 18.5D Push-in terminal zones of low activity • Suitable for direct control of up to 8 DALI lighting ballasts • Extensive sensing area up to 64 m2 • Two sensing areas: “presence” suitable for zones of low activity, and “movement” suitable for transit areas or zones of high activity zones of low activity • Extensive sensing area up to 64 m2 • Two sensing areas: “presence” suitable for zones of low activity, and “movement” suitable for transit areas or zones of high activity For outline drawings see page 16 Supply specification Coil specification V AC (50/60 Hz) Rated power VA (50 Hz)/W Operating range V AC (50/60 Hz) Supply specification Type of BUS Supply voltage V DC Rated consumption mA Technical data Ambient light intervention threshold lx Light ON time after last detection Ambient temperature range °C Protection category 110…230 1.5/1 96…253 — — — — — — KNX 30 10 10…500 10 s…35 min –10…+50 IP 40 1…1500 0.1 s…18 h –5…+45 IP 40 J X-2017, www.findernet.com Approvals (according to type) 7 18 SERIES 18 SERIES PIR movement detectors 10 A Movement detectors with Push-in terminals For internal installation - with volt-free output contact 18.41 18.61 Type 18.41 --Corridor (ceiling) installation Type 18.61 --Wall mount installation • Extensive sensing area up to 120 m2 • Modern design • Quick installation thanks to push-in terminals • 1 NO contact 10 A, with “zero crossing” switching • Wall mounting compatible with 60 mm box and 2 or 3 module box • Double terminals for easy “looping” in and out • 1 NO 10 A • 1 NO 10 A • Applications: hotel and offices • Specifically for wall mounting corridors, transit areas • Wide angle: 180° • Sensing area 30 meters length • Wall mounting compatible 18.41/18.61 Push-in terminal and 4 meters width with 60 mm box NOTE: with 110…125 V AC supply, the Ratings (AC1, AC15 and lamp loads) must be reduced by 50 % (e.g. 500 W instead of 1000 W) For outline drawings see page 16 Contact specification Number of contacts Rated current/Maximum peak current Rated voltage/ Maximum switching voltage A V AC 1 NO (SPST-NO) 1 NO (SPST-NO) 10/20 (100 A - 5 ms) 10/20 (100 A - 5 ms) 250/400 250/400 Rated load AC1 VA 2500 2500 Rated load AC15 VA 450 450 incandescent/halogen W 1000 1000 500 500 Nominal lamp rating 230 V: fluorescent lamp with electronic ballast W fluorescent lamp with electromecanical ballast W J 350 350 CFL W 300 300 LED 230 V W 300 300 300 300 halogen or LV LED with electronic ballast W halogen or LV LED with electromechanical ballast W 500 500 AgSnO2 AgSnO2 110…230 110…230 1.5/1 1.5/1 V AC (50/60 Hz) 96…253 96…253 cycles 100 · 103 100 · 103 lx 1…500 1…500 Standard contact material Supply specification Coil specification Rated power Operating range V AC (50/60 Hz) VA (50 Hz)/W Electrical life at rated load AC1 Ambient light intervention threshold Light ON time after last detection Sensing area diameter Ambient temperature range Protection category Approvals (according to type) 8 °C 12 s…35 min 12 s…35 min See diagram page 15 See diagram page 15 –10…+50 –10…+50 IP 40 IP 40 X-2017, www.findernet.com Technical data 18 SERIES PIR movement detectors 10 A 18 SERIES 18.91 Movement detectors for internal installation Type 18.91 --Wall mount installation • External push-button connection • Modern design • 1 output with “zero crossing” switching • Wall mounting compatible with 3 module housing, complete with adaptor for following frames: - BTicino series Axolute - BTicino series Light tech - BTicino series Living - BTicino series Living light Air - BTicino series Matix - Gewiss series Chorus - Vimar series Eikon - Vimar series Idea - Vimar series Arkè - Vimar PLANA • White or black color version • Specifically for wall mounting • Wide angle: 110° • Applications: corridors, transit areas, toilets, staircases 18.91 Screw terminal For outline drawings see page 16 Output data Rated voltage V AC 230 Power max. W 200 Power min. W 3 Nominal lamp rating 230 V: incandescent/halogen W toroidal electromagnetic transformers for LV halogen W E-core electromagnetic transformers for LV halogen W electronic transformers (ballasts) for LV halogen W 200 200 J 200 200 compact fluorescent (CFL) W 200 230 V LED W 200 electronic transformers for LV LED W 200 V AC (50/60 Hz) 230 Supply specification Nominal voltage (UN) Rated power VA(50Hz)/W Operating range 14/0.5 (0.8…1.1)UN Technical data X-2017, www.findernet.com Ambient light intervention threshold lx Light ON time after last detection 10 s…20 min Sensing area Ambient temperature range Protection category 5…500 (black)/6…600 (white) See diagram page 15 °C –10…+50 IP 20 Approvals (according to type) 9 18 SERIES 18 SERIES PIR movement and presence detectors 10 A Ordering information Example: 18 series, PIR movement detector for internal installations, wall mounting, 1 NO 10 A contact, 120…230 V AC supply. 1 8 . 0 Series Type 0 = Internal installation - wall mounting 1 = External installations 2 = Internal ceiling installation - surface mounting 3 = Internal ceiling installation - recessed mounting 4 = PIR movement detector for corridors 5 = PIR movement and presence detector 6 = PIR movement detector wall mounting 9 = PIR movement detector wall mounting residential switch boxes A = External installations IP 55, push-in terminals 1 . 8 . 2 3 0 . 0 0 0 0 Program 0 = Standard B=B  luetooth programming Contact circuit 0 = Voltage output 3 = Volt-free output contact Supply voltage 024 = 24 V AC/DC for types 18.21/31-0300 only 030 = KNX Bus 230 = 120…230 V for types 18.01, 18.11, 18.21, 18.31 230 = 110…230 V for types 18.A1, 18.41, 18.51, 18.51.B300, 18.61, 18.5D 230 = 230 V for type 18.91 Special version 31 = High ceilings, (30 s…35 min) 40 = Push-button connection (only 18.51) 40 = Push-button connection, white color (only 18.91) 42 = Push-button connection, black color (only 18.91) Supply version 0 = AC (50/60 Hz)/DC (24 V only) 8 = AC (50/60 Hz) 9 = DC No. of poles/Output 1 = Single pole switching 1 NO (SPST-NO), 10 A D = PIR movement and presence detector with DALI interface K=P  IR movement and presence detector with KNX interface Codes 18.01.8.230.0000 18.11.8.230.0000 18.21.0.024.0300 18.21.8.230.0000 18.21.8.230.0300 18.31.0.024.0300 18.31.8.230.0000 18.31.8.230.0300 18.31.8.230.0031 18.41.8.230.0300 18.51.8.230.0300 18.51.8.230.0040 18.51.8.230.B300 18.61.8.230.0300 18.91.8.230.0040 18.91.8.230.0042 18.A1.8.230.0000 18.5D.8.230.0000 18.5K.9.030.0000 X-2017, www.findernet.com J 10 18 SERIES PIR movement and presence detectors 10 A 18 SERIES Technical data Insulation Dielectric strength between open contactsV AC 1000 (except for type 18.91 TRIAC output) Between supply and contact V AC 1500 (types 18.21…0300, 18.31…0300, 18.41, 1851, 18.61) EMC specifications Type of test Electrostatic discharge Reference standard contact discharge EN 61000-4-2 4 kV air discharge EN 61000-4-2 Radiated electromagnetic field (80…2000 MHz) Fast transients (burst 5/50 ns, 5 and 100 kHz) Voltage pulses on supply terminals (surge 1.2/50 µs) Radiofrequency common mode voltage (0.15…230 MHz) Voltage dips Short interruptions Radiofrequency conducted emissions Radiated emissions 8 kV EN 61000-4-3 3 V/m on supply terminals EN 61000-4-4 1 kV common mode EN 61000-4-5 4 kV (2 kV for 18.91) differential mode EN 61000-4-5 4 kV (2.5 kV for 18.01/11, 1 kV for 18.91) on supply terminals EN 61000-4-6 3 V 70% UN , 40% UN EN 61000-4-11 10 cycles EN 61000-4-11 10 cycles (0.15…30)MHz EN 55014 class B (30…1000)MHz EN 55014 class B 18.01, 18.11, 18.21, 18.31,18.91 Terminals Type Screw terminal Screw torque Nm 0.5 Max. wire size solid cable mm2 1 x 6 / 2 x 4 AWG 1 x 10 / 2 x 12 Wire strip length mm 9 18.41, 18.51, 18.51…B300, 18.61, 18.A1 Push-in (see pag. 18) — stranded cable solid cable stranded cable 1 x 4 / 2 x 2.5 2.5 2.5 1 x 12 / 2 x 14 14 14 9 8 8 Other data Power lost to the environment without output current W 0.3 with rated output current W 1.4 • Following the initial power-on, and power-on following a power interruption, the detector makes a hardware-software initialisation for approximately 30 seconds. However, the behavior of the output during this 30 seconds will depend on certain circumstances: --If the detector was in the On state before the power interruption, and if the lighting level is (currently) below the pre-set threshold, then the output contact will immediately close when the power is re-applied, for the time delay set by the potentiometer (irrespective of whether movement is being detected). --If the detector was in the Off state before the power interruption, or if the ambient light is currently over the pre-set threshold, then the detector will not switch-on until the end of the initialisation phase (assuming movement is then detected). X-2017, www.findernet.com J 11 18 SERIES PIR movement and presence detectors 10 A 18 SERIES Wiring diagram Type 18.01/18.11 Type 18.21/18.31/18.31…0031 Type 18.21-0300/18.31-0300 L L L N N N 2 2 1 1 2 1 1 = ambient light intervention threshold 2 = light ON time following last detection Type 18.41 Type 18.51/18.51-B300 Type 18.61 L L L N N N 2 1 1 3 2 3 1 2 3 1 = light ON time following last detection 2 = sensitivity setting 3 = ambient light intervention threshold Note: not for 18.51…B300 The nominal lamp rating as stated in the contact specification applies when wiring is realized in accordance with the diagrams above. If the load is powered from a phase different to that powering the Movement detector, then a 50% reduction in the lamp rating must be considered. Type 18.51…0040 Type 18.5D L L N N J Type 18.91 Type 18.A1 L L N 12 X-2017, www.findernet.com N 18 SERIES PIR movement and presence detectors 10 A 18 SERIES Wiring diagram Type 18.01/18.11 Type 18.01/18.21 Type 18.21/18.31/18.31…0031 L L L N N N Note: Observe the polarity indicated for Phase and Neutral Type 18.51-B300 - Bluetooth Through the use of Bluetooth LE (Low Energy) technology programming the detector’s operating characteristics can be easily and conveniently done using an Android or iOS smartphone. After installing the 18.51, simply download the Free App Finder Toolbox from Google and Apple’s official stores and set all the required parameters. Finder Toolbox Android, Google Play and the Google Play logo are trademarks of Google Inc. Apple is a trademark of Apple Inc. App Store is a service mark of Apple Inc. Detectors can be named and uniquely identified within a building. The ambient light level threshold can be adjusted between 4 lux and 1000 lux, the Light On delay time can be set from 12 seconds to 25 minutes, and the movement detector set to one of three sensitivity levels. When Bluetooth connection is made to a detector a red LED signals the correct pairing and that all the set parameters have been transferred. The detector then responds with two feedback values - brightness as read by the light sensor in the detector and the contact status, if closed (On) or open (Off ). For security, the detectors can be locked by a selector switch and a 4-digit PIN - preventing parameter changes by unauthorized persons. X-2017, www.findernet.com J 13 18 SERIES PIR movement and presence detectors 10 A 18 SERIES Functions Type Functions 18.51…0040 Lux Movement Push-button function A control pulse on the push-button inverts the status of the output relay, until the timing after the last movement detected is elapsed. Dynamic Light Compensation By incorporating Finder’s Patented “light feedback compensation” principle, the 18.51…0040 is able to calculate the artificial light contributed by the lamps controlled by the output relay. In effect, this means the 18.51…0040 is able to continuously monitor the natural ambient light level, even when the output is On. As a consequence, whenever the natural light level exceeds the threshold setting the output is forced Off. This can significantly minimises the time the lighting is On, particularly where there is a high level of traffic - and cost savings can be considerable. This is an advance over other types of movement detectors, which are unable to identify the natural ambient light level when the output is On and so can only turn Off after the time delay that follows the last detected movement. In busy areas this may mean that the movement detector is being continuously re-triggered and maintained in the On state, even though the natural light level has long risen above the threshold. 18.5D Lux Movement 100% Comfort - Daylight-linked constant light level control Adjusts to maintain a constant brightness level considering the detection of movement and the level of daylight - increasing or decreasing the power of the artificial light as appropriate. Suitable for small offices, classrooms or workplaces. This allows considerable energy saving while maintaining a comfortable level of illumination. OFF Lux Simplicity - ON/OFF control with early warning Works as a simple movement detector, activating the lamps at 100% power. But provides an early warning of the next shutdown with a power reduction to 50% for 20 seconds. Avoids a sudden total shutdown of lighting. Movement 100% 50% OFF Lux Movement 100% 50% 10% OFF 18.91 Lux Movement 14 Courtesy - ON/OFF control with early warning + courtesy light level If the brightness level is lower than the set value, artificial light is maintained at 10% power, guaranteeing a minimum level of illumination at all times. When movement is detected, the power of the lamps is raised to 100%. There is an early warning of any reduction from the 100% power level by a reduction to 50% for 20 seconds. Suitable for common areas, lobbies, corridors, elevator zones.  etection of movement D Detected movement closes, or keeps closed, the output contact. Operating the push-button closes, or keeps closed, the output contact - for the set time T. X-2017, www.findernet.com J 18 SERIES PIR movement and presence detectors 10 A 18 SERIES Sensing area 18.01, 18.11, 18.A1 - Wall mounting Side view 18.21, 18.31 - Ceiling mounting 18.01, 18.11 - Ceiling mounting Plan view 18.31…0031 - Internal ceiling installation, surface mounting 18.31…0031 - High ceilings installations Movement and presence detector 18.41 18.51/18.51...B300/18.5K For applications with high ceilings (up to 6 meters) 18.61 J 18.91 X-2017, www.findernet.com Accessories Beam limiter (supplied with the type 18.21/31/41/51) At an installation height of 2.8 meters the area of survey will reduce at: 18.21/18.31: diameter 2 meters 18.41: 2.5 x 6 meters Example: 18.21/18.31 with Beam limiter 18.51: 2 x 2 meters 15 18 SERIES 18 SERIES PIR movement and presence detectors 10 A Outline drawings Type Suspended ceiling mounting Recess mounting Surface mounting 18.21 18.31 43.6 18.41 31.6 18.31…0031 18.51 18.5D 18.5K 18.51…B300 J X-2017, www.findernet.com 18.61 16 18 SERIES PIR movement and presence detectors 10 A 18 SERIES Outline drawings Type 18.01 Type 18.11 Type 18.A1 J X-2017, www.findernet.com Type 18.91 17 18 SERIES 18 SERIES PIR movement detectors 10 A Push-in terminals for 18.41, 18.51, 18.5D, 18.61 and 18.A1 The push-in terminals permit the quick connection of solid wires or ferrules by their simple insertion into the terminal (A). It is possible to open the terminal to extract the wire by first pushing down on the push-button using a screwdriver or fingers (C). For stranded cable it is necessary first to open the terminal using the push button, both for the extraction (C) and insertion (B). A B 1 C 2 1 2 Double terminals for the easy “looping” between multiple 18 Series. The Max. wire size for each terminal is 2.5 mm2. The terminals are equipped with a test hole to take a test probe. X-2017, www.findernet.com J 18 Please see general technical information
18.01.8.230.0000 价格&库存

很抱歉,暂时无法提供与“18.01.8.230.0000”相匹配的价格&库存,您可以联系我们找货

免费人工找货
18.01.8.230.0000
  •  国内价格
  • 1+373.67972

库存:2