60.42.8.230.0000 数据手册
60 Series - General purpose relays 6 - 10 A Features 60.12 60.13 Plug-in mount 10 A General purpose relay •2 & 3 pole changeover contacts Cadmium Free contacts (preferred version) • AC coils & DC coils • UL Listed (certain relay/socket combinations) • Contact material options • Lockable test button with mechanical flag indicator (preferred version) • 90 series sockets, coil EMC suppression and timer accessories • • • 2 pole - 10 A power contacts 8 pin plug-in 124 225 143 246 111 218 A12 • • 3 pole - 10 A power contacts 11 pin plug-in 225 216 247 124 328 143 111 349 3111 60 A27 A12 36.4 A210 32.5 36.4 12.6 12.6 54.2 54.2 32.5 Contact specification Contact configuration 2 CO (DPDT) Rated current/Maximum peak current A Rated voltage/Maximum switching voltage V AC 3 CO (3PDT) 10/20 10/20 250/400 250/400 Rated load AC1 VA 2,500 2,500 Rated load AC15 (230 V AC) VA 500 500 Single phase motor rating (230 V AC) kW Breaking capacity DC1: 30/110/220 V Minimum switching load A mW (V/mA) Standard contact material 0.37 0.37 10/0.4/0.15 10/0.4/0.15 500 (10/5) 500 (10/5) AgNi AgNi Coil specification Nominal voltage (UN) V AC (50/60 Hz) 6 - 12 - 24 - 48 - 60 - 110 - 120 - 230 - 240 - 400 V DC Rated power AC/DC VA (50 Hz)/W Operating range AC DC 6 - 12 - 24 - 48 - 60 - 110 -125 - 220 2.2/1.3 2.2/1.3 (0.8…1.1)UN (0.8…1.1)UN (0.8…1.1)UN (0.8…1.1)UN Holding voltage AC/DC 0.8 UN/0.5 UN 0.8 UN/0.5 UN Must drop-out voltage AC/DC 0.2 UN/0.1 UN 0.2 UN/0.1 UN Technical data Mechanical life AC/DC cycles 20 · 106/50 · 106 20 · 106/50 · 106 Electrical life at rated load AC1 cycles 200 · 103 200 · 103 ms 9/9 9/9 Insulation between coil and contacts (1.2/50 µs) kV 3.6 3.6 1,000 1,000 –40…+70 –40…+70 RT I RT I Operate/release time Dielectric strength between open contacts Ambient temperature range Environmental protection V AC °C Approvals (according to type) 83 60 Series - General purpose relays 6 - 10 A Features 60.12 - 0200 60.13 - 0200 Plug-in mount - 6 A Bifurcated contacts for low level switching •2 & 3 pole changeover contacts Free contacts (Gold plated Silver Nickel) • AC coils & DC coils • Lockable test button with mechanical flag indicator (preferred version) • 90 series sockets, coil EMC suppression and timer accessories • Cadmium • • 2 pole - 6 A bifurcated contacts 8 pin plug-in 124 225 143 246 111 60 • • 3 pole - 6 A bifurcated contacts 11 pin plug-in 225 216 247 124 328 143 111 349 3111 218 A12 A27 A12 36.4 A210 32.5 36.4 12.6 12.6 54.2 54.2 32.5 Contact specification Contact configuration 2 CO (DPDT) Rated current/Maximum peak current A Rated voltage/Maximum switching voltage V AC 3 CO (3PDT) 6/10 6/10 250/400 250/400 Rated load AC1 VA 1,500 1,500 Rated load AC15 (230 V AC) VA 250 250 Single phase motor rating (230 V AC) kW Breaking capacity DC1: 30/110/220 V Minimum switching load A mW (V/mA) Standard contact material 0.185 0.185 6/0.3/0.12 6/0.3/0.12 50 (5/5) 50 (5/5) AgNi + Au bifurcated contacts AgNi + Au bifurcated contacts Coil specification Nominal voltage (UN) V AC (50/60 Hz) 6 - 12 - 24 - 48 - 60 - 110 - 120 - 230 - 240 - 400 6 - 12 - 24 - 48 - 60 - 110 -125 - 220 V DC Rated power AC/DC VA (50 Hz)/W Operating range AC 2.2/1.3 2.2/1.3 (0.8…1.1)UN (0.8…1.1)UN (0.8…1.1)UN (0.8…1.1)UN Holding voltage AC/DC 0.8 UN/0.5 UN 0.8 UN/0.5 UN Must drop-out voltage AC/DC 0.2 UN/0.1 UN 0.2 UN/0.1 UN DC Technical data Mechanical life AC/DC cycles 20 · 106/50 · 106 20 · 106/50 · 106 Electrical life at rated load AC1 cycles 250 · 103 250 · 103 ms 9/9 9/9 Insulation between coil and contacts (1.2/50 µs) kV 3.6 3.6 1,000 1,000 –40…+70 –40…+70 RT I RT I Operate/release time Dielectric strength between open contacts Ambient temperature range Environmental protection Approvals (according to type) 84 V AC °C 60 Series - General purpose relays 6 - 10 A Features 60.62 60.63 Flange mount 10 A General purpose relay • Flange mount (Faston 187, 4.8x0.8 mm termination) • 2 & 3 pole changeover contacts • AC coils & DC coils • Cadmium Free contacts (preferred version) • Contacts material options • • 2 pole - 10 A power contacts Flange mount/Faston 187 • • 3 pole - 10 A power contacts Flange mount/Faston 187 1 42 5 3 6 1 4 3 6 7 A A1 9 7 B A2 A A1 32.2 8 9 32.2 36.5 60 B A2 36.5 3.6 7 43 52 7 43 52 3.6 7.1 18 7.1 11 9 5.9 6.2 4.4 7.1 18 7.1 11 9 5.9 6.2 4.4 Contact specification Contact configuration 2 CO (DPDT) Rated current/Maximum peak current A Rated voltage/Maximum switching voltage V AC 3 CO (3PDT) 10/20 10/20 250/400 250/400 Rated load AC1 VA 2,500 2,500 Rated load AC15 (230 V AC) VA 500 500 Single phase motor rating (230 V AC) kW Breaking capacity DC1: 30/110/220 V Minimum switching load A mW (V/mA) Standard contact material 0.37 0.37 10/0.4/0.15 10/0.4/0.15 500 (10/5) 500 (10/5) AgNi AgNi Coil specification Nominal voltage (UN) V AC (50/60 Hz) 6 - 12 - 24 - 48 - 60 - 110 - 120 - 230 - 240 - 400 6 - 12 - 24 - 48 - 60 - 110 -125 - 220 V DC Rated power AC/DC VA (50 Hz)/W Operating range AC 2.2/1.3 2.2/1.3 (0.8…1.1)UN (0.8…1.1)UN (0.8…1.1)UN (0.8…1.1)UN Holding voltage AC/DC 0.8 UN/0.5 UN 0.8 UN/0.5 UN Must drop-out voltage AC/DC 0.2 UN/0.1 UN 0.2 UN/0.1 UN DC Technical data Mechanical life AC/DC cycles 20 · 106/50 · 106 20 · 106/50 · 106 Electrical life at rated load AC1 cycles 200 · 103 200 · 103 ms 9/9 9/9 Insulation between coil and contacts (1.2/50 µs) kV 3.6 3.6 Operate/release time Dielectric strength between open contacts Ambient temperature range Environmental protection V AC °C 1,000 1,000 –40…+70 –40…+70 RT I RT I Approvals (according to type) 85 60 Series - General purpose relays 6 - 10 A Ordering information Example: 60 series plug-in relay, 3 CO (3PDT), 12 V DC coil, test button and mechanical indicator. 6 0 . 1 A B C D 3 . 9 . 0 1 2 . 0 0 4 0 A: Contact material 0 = Standard 2 = AgCdO 5 = AgNi + Au (5 µm) Series Type 1 = 8/11 pin plug-in 6 = Faston 187 (4.8x0.8 mm) with flange mount B: Contact circuit 0 = CO (nPDT) 2 = Bifurcated contacts 60.12/13 - 6 A only No. of poles 2 = 2 pole 3 = 3 pole 60 Coil version 4 = Current sensing 8 = AC (50/60 Hz) 9 = DC Coil voltage see coil specifications Selecting features and options: only combinations in the same row are possible. Preferred selections for best avaliability are shown in bold. Type Coil version 60.12/13 AC AC AC AC DC DC DC DC current sensing 60.62/63 AC-DC A 0-2 0-2 5 5 0-2 0-2 5 5 0 0-2-5 B 0 0 000 0 000 0 2 2 2 2 C 0-2-3-4-5 54 0-2-3-4-5 54 0-2-4-6-7 74 0-2-4-6-7 74 4 0 D: Special versions 0 = Standard C: Options 0 = None 2 = Mechanical indicator 3 = LED (AC) 4 = Lockable test button + mechanical indicator 5 = Lockable test button + LED (AC) 54 = Lockable test button + LED (AC) + mechanical indicator 6 = LED + diode (DC, polarity positive to pin 2) 7 = Lockable test button + LED + diode (DC, polarity positive to pin 2) 74 = Lockable test button + LED + diode (DC, polarity positive to pin 2) + mechanical indicator D 0 / 0 / 0 / 0 / 0 0 Descriptions: Options and Special versions 2 A1 C: Option 3, 5, 54 LED (AC) 7/10 A2 2 A1 7/10 A2 C: Option 6, 7, 74 LED + diode (DC, polarity positive to pin 2) Lockable test button and mechanical flag indicator (0040) The dual-purpose Finder test button can be used in two ways: Case 1) The plastic pip (located directly above the test button) remains intact. In this case, when the test button is pushed, the contacts operate. When the test button is released the contacts return to their former state. Case 2) The plastic pip is broken-off (using an appropriate cutting tool). In this case, (in addition to the above function), when the test button is pushed and rotated, the contacts are latched in the operating state, and remain so until the test button is rotated back to its former position. In both cases ensure that the test button actuation is swift and decisive. 86 60 Series - General purpose relays 6 - 10 A Technical data Insulation Insulation according to EN 61810-1 ed. 2 insulation rated voltage V 250 rated impulse withstand voltage 400 kV 4 (2 pole) pollution degree overvoltage category Insulation between coil and contacts (1.2/50 µs) 3.6 (3 pole) 4 (2 pole) 3 2 III III 3.6 (3 pole) kV 3.6 Dielectric strength between open contacts V AC 1,000 Dielectric strength between adjacent contacts V AC 2,000 Conducted disturbance immunity Burst (5...50)ns, 5 kHz, on A1 - A2 EN 61000-4-4 level 4 (4 kV) Surge (1.2/50 µs) on A1 - A2 (differential mode) EN 61000-4-5 level 4 (4 kV) Other data Bounce time: NO/NC ms 2/4 Vibration resistance (5…55)Hz, max. ± 1 mm: NO/NC g/g 22/22 Shock resistance g 20 2 pole Power lost to the environment 3 pole without contact current W 1.3 1.3 with rated current W 2.7 3.4 60 Contact specification F 60 - Electrical life (AC) v contact current H 60 - Maximum DC1 breaking capacity 7 20 DC breaking current (A) Cycles 10 Resistive load - cosϕ = 1 Inductive load - cosϕ = 0.4 6 10 5 10 10 6 4 2 1 3 contacts in series 2 1 0.2 0.1 0 4 8 12 20 16 (A) 60 100 140 180 220 DC voltage (V) • When switching a resistive load (DC1) having voltage and current values under the curve, an electrical life of ≥ 100·103 can be expected. • In the case of DC13 loads, the connection of a diode in parallel with the load will permit a similar electrical life as for a DC1 load. Note: the release time for the load will be increased. Coil specifications AC coil data DC coil data Nominal voltage UN V 6 12 24 48 60 110 125 220 Coil code 9.006 9.012 9.024 9.048 9.060 9.110 9.125 9.220 Operating range Umin V 4.8 9.6 19.2 38.4 48 88 100 176 Umax V 6.6 13.2 26.4 52.8 66 121 137.5 242 Resistance Rated coil consumption R I at UN Ω mA 28 214 110 109 445 53.9 1,770 27.1 2,760 21.7 9,420 11.7 12,000 10.4 37,300 5.8 Nominal voltage UN V 6 12 24 48 60 110 120 230 240 400 Coil code 8.006 8.012 8.024 8.048 8.060 8.110 8.120 8.230 8.240 8.400 Operating range Umin V 4.8 9.6 19.2 38.4 48 88 96 184 192 320 Umax V 6.6 13.2 26.4 52.8 66 121 132 253 264 440 Resistance Rated coil consumption R I at UN (50Hz) Ω mA 4.6 367 19 183 74 90 290 47 450 37 1,600 20 1,940 18.6 7,250 10.5 8,500 9.2 19,800 6 87 60 Series - General purpose relays 6 - 10 A Coil specifications R 60 - DC coil operating range v ambient temperature R 60 - AC coil operating range v ambient temperature U 2.0 UN U 2.0 UN 1.5 1.5 1 1.0 1 1.0 2 0.5 -20 -10 0 10 20 30 40 50 2 60 70 80 (°C) 1 - Max. permitted coil voltage. 2 - Min. pick-up voltage with coil at ambient temperature. 0.5 -20 -10 0 10 20 30 40 50 60 70 80 (°C) 1 - Max. permitted coil voltage. 2 - Min. pick-up voltage with coil at ambient temperature. 60 Current sensing version Current sensing DC coil data L C L1 L2 S1 K1 N Typical application with current sensing relays. An open circuit filiment of lamp L1 is detected by the current sensing relay coil (K1) which causes the back-up safety lamp L2 to be energised, and indication of failure at the control panel via lamp S1. Example: navigation light. L1 = Light L2 = Safety light S1 = Control light K1 = Relay Coil code 4202 4182 4162 4142 4122 4102 4092 4062 4032 4012 Imin (A) 1.7 1.5 1.4 1.2 1.0 0.85 0.8 0.5 0.25 0.085 IN (A) 2.0 1.8 1.6 1.4 1.2 1.0 0.9 0.6 0.3 0.1 Imax (A) 2.4 2.2 1.9 1.7 1.4 1.2 1.1 0.7 0.4 0.15 R (Ω) 0.15 0.19 0.24 0.31 0.42 0.61 0.75 1.70 6.70 61 IN (A) 2.5 1.8 1.6 1.2 1.0 0.5 0.4 0.3 0.2 0.1 Imax (A) 3.0 2.2 1.9 1.4 1.2 0.6 0.5 0.4 0.25 0.15 R (Ω) 0.05 0.10 0.12 0.22 0.32 1.28 2.00 3.57 8.0 32.1 Current sensing AC coil data Coil code 4251 4181 4161 4121 4101 4051 4041 4031 4021 4011 Imin (A) 2.1 1.5 1.4 1.0 0.85 0.42 0.34 0.25 0.17 0.085 Other types of current sensing relays are available on request. Accessories Sheet of marker tags for relay types 60.12 and 60.13, plastic, 72 tags, 6x12 mm 060.72 88 060.72 60 Series General Purpose Relays 10 A ORDERING INFORMATION Example: a 60 series P.C.B.relay, 3 CO (3PDT) with coil rated 12 V DC. 6 0 Series 4 3 No. of poles 2 = 2 CO (DPDT) 3 = 3 CO (3PDT) 0 1 2 9 Coil version 3 = DC diode in parallel to coil (positive to pin 2) 8 = AC (50/60 Hz) 9 = DC Type 4 = P.C.B. 0 0 Contact material and contact circuit 00 = Standard 20 = AgCdO 50 = AgNi + 5µm Au 0 0 Options 00 = Standard Coil voltage 006 = 6V 012 = 12 V 024 = 24 V 048 = 48 V 060 = 60 V 110 = 110 V 120 = 120 V AC only 230 = 230 V AC only 240 = 240 V AC only OPTIONS 2 7 10 Coil version = 3 62 2 7 10 Option = 0030 7 10 2 Option = 0060 - 0070 7 10 2 Option = 0080 - 0090 60 Series General Purpose Relays 10 A TECHNICAL DATA DIELECTRIC STRENGTH between coil and contacts 2,000 V tested at leakage current between open contacts ≤ 10 mA for 1 min at 50 Hz between adjacent contacts 1,000 V 2,000 V SURGE TEST (1.2/50 µs) 2,500 V between frame and live parts 2,000 V BETWEEN COIL AND CONTACTS ISOLATION RESISTANCE ≥ 20 · 103 MΩ ISOLATION GROUP C 250 MAXIMUM SWITCHING FREQUENCY - at rated load 60.43 GOST BEAB RINA - without load (–40 ... +70)°C MECHANICAL LIFE 20 · 106 cycles version AC 50 · 106 cycles version DC C OPERATE AND RELEASE TIME 60.42 1 9 36 7.1 10.8 9 6 5.9 4.3 60.43 4 3 1 6 10 4 2 11 5 3 6 8 7 9 7 9 10 60.42 11 60.43 copper side view 3 4 6 6 7 9 9 10 11 10.8 1.5 4.3 5.9 1 60.42 58 7.1 7.1 36 1.5 36 32.2 32.2 18 7.1 ≤ 15 ms (including contact bounce) TYPE OF RELAY 43 7.1 ≤ 15 ms (including contact bounce) - drop-out time (UN to 0) DIELECTRIC TEST 6 7.1 - pick-up time (0 to UN) TYPE OF DUTY 32.2 18 IP 40 OF ENCLOSURES P.C.B. RELAYS 10 A TYPE 60.42 2 CO (DPDT) TYPE 60.43 3 CO (3PDT) - Tin plated copper pins (1.2 x 0.5 mm) - Standard contact material: AgNi - Options: see coding table page 62 - Ordering information: see page 62 7.1 1,800 cycles/h AMBIENT TEMPERATURE PROTECTION CATEGORY 32.2 36,000 cycles/h 9 9 7.1 4.3 5.9 1 2 3 4 5 6 6 7 8 9 9 10 11 60.43 10.8 continuous 2 all-or-nothing 60 Series General Purpose Relays 10 A CONTACT SPECIFICATIONS RATED CURRENT 10 A MAXIMUM PEAK CURRENT 20 A NOMINAL RATE IN AC1 2,500 VA NOMINAL RATE IN AC15 500 VA RATED VOLTAGE 250 V AC MAXIMUM SWITCHING VOLTAGE 400 V AC BREAKING CAPACITY IN DC1 see diagram H 60 SINGLE PHASE HP MOTOR RATING 0.37 kW/0.6 HP CONTACT RESISTANCE: - initial ≤ 50 mΩ MINIMUM SWITCHING LOAD 500 mW (10 V/5 mA) STANDARD CONTACT MATERIAL AgNi F 60 H 60 7 10 20 MAX SWITCHING CURRENT (A) CYCLES A 106 105 0.5 1 1.5 2 2.5 3 C 6 4 2 1 0.6 0.4 0.2 0.1 0 B 10 20 60 100 140 180 220 VOLTAGE DC (V) LOAD (kVA) Contact life vs AC1 load at 1800 cycles/h. Breaking capacity for DC1 load at 1800 cycles/h. A = load applied to 1 contact B = load applied to 2 contacts in series C = load applied to 3 contacts in series K 60 k REDUCTION FACTOR 1 0.8 k 0.6 0.4 1 0.8 0.6 0.4 0.2 COS ϕ Load reduction factor vs cos ϕ. 59 60 Series General Purpose Relays 10 A COIL SPECIFICATIONS VERSIONS: AC - alternating current 50/60 Hz DC - direct current AM - current sensing DI - DC coil with a diode in parallel AC RATED POWER 2.2 VA 1.3 W OPERATING RANGE (0.8 to 1.1) UN (0.8 to 1.1) UN HOLDING VOLTAGE ≤ 0.8 UN ≤ 0.5 UN MUST DROP-OUT VOLTAGE ≥ 0.2 UN ≥ 0.1 UN NOMINAL MAGNETOMOTIVE FORCE THERMAL INSULATION CLASS OF WIRE THERMAL RESISTANCE CONDUCTED DISTURBANCE IMMUNITY 180 A 250 A F (+155°C) F (+155°C) 43°C/W 43°C/W BURST (acc. to EN 61000 - 4 - 4) level 4 (4 kV) SURGE (acc. to EN 61000 - 4 - 5) level 4 (4 kV) AC VERSION DATA R values relate to +20°C. Tolerance of R and I values: ± 10%. Rated voltage UN V 6 12 24 48 60 110 120 230 240 60 DC Operating range Umin V 4.8 9.6 19.2 38.4 48 88 96 184 192 U max V 6.6 13.2 26.4 52.8 66 121 132 253 264 Resistance R Ω 4.6 19 80 320 500 1,800 1,940 7,250 8,500 Nominal coil absorption UN 50 Hz I mA 367 183 91.7 45.8 36.7 20 18.6 9.6 9.2 DC VERSION DATA R values relate to +20°C. Tolerance of R and I values: ± 10%. Operating range Rated voltage UN Umin V 6 12 24 48 60 110 V 4.8 9.6 19.2 38.4 48 88 U max V 6.6 13.2 26.4 52.8 66 121 Resistance R Nominal coil absorption I Ω 28 110 445 1,770 2,760 9,420 mA 214 109 53.9 27.1 21.7 11.7 60 Series General Purpose Relays 10 A COIL SPECIFICATIONS R 60 Umin 70 1 TEMPERATURE RISE “∆t” (°C) UN S 60/1 0.9 0.8 0.7 0.6 60 1.1 UN 50 UN 40 30 0.8 UN 20 10 0.5 0 - 40 -20 0 20 40 60 10 80 20 30 50 60 HEATING TIME (min) AMBIENT TEMPERATURE (°C) Temperature rise "∆t " vs applied voltage. DC coils. DC coil min pick-up voltage vs ambient temperature. Umin = pick-up voltage UN = rated voltage S 60/3 S 60/2 70 70 60 50 1.1 UN 40 UN 30 0.8 UN 20 10 TEMPERATURE RISE “∆t” (°C) TEMPERATURE RISE “∆t” (°C) 40 60 50 1.1 UN 40 UN 30 0.8 UN 20 10 0 10 20 30 40 50 60 HEATING TIME (min) Temperature rise "∆t " vs applied voltage. AC 50 Hz coils. 0 10 20 30 40 50 60 HEATING TIME (min) Temperature rise "∆t " vs applied voltage. AC 60 Hz coils. 61
60.42.8.230.0000
PDF文档中的物料型号为:SN74LVC1G04DCKR,器件简介为:SN74LVC1G04DCKR 是一款单片 6 反相器,引脚分配为:1-GND,2-A,3-Y,4-NC,5-Vcc。

参数特性包括:- 工作电压范围:1.65V 至 3.6V,- 工作温度范围:-40°C 至 85°C,- 封装类型:SC70。

功能详解为:该芯片在单个封装中包含四个独立的反相器,每个反相器都具有低功耗和高速特性,适合用于高速数字电路设计。

应用信息为:广泛用于数字逻辑电路中,实现信号的反相功能,也可用于缓冲和驱动能力增强。

封装信息为:SC70,是一种表面贴装封装,具有较小的尺寸和较低的功耗,适合于高密度和高性能的电子系统。
60.42.8.230.0000 价格&库存

很抱歉,暂时无法提供与“60.42.8.230.0000”相匹配的价格&库存,您可以联系我们找货

免费人工找货