    FINDER

  • 封装:

    -

  • 描述:

    固态 SPST-NO(1 Form A) 带集成散热器的 SSR

  • 详情介绍
  • 数据手册
  • 价格&库存
77.11.9.024.8250 数据手册
Solid State Relays 5 - 15 - 30 - 50 A Drying kilns Heating and cooling Lighting control in corridors (for hotels, offices and hospitals) Bottling plant Labelling machines Packaging machines 77 SЕRIES FINDER reserves the right to alter characteristics at any time without notice. FINDER assumes no liability for damage to persons or property, caused as a result of the incorrect use or application of its products. 77 SERIES Modular Solid State Relays 5 A 77 SERIES 77.01.x.xxx.8050 5 A modular SSR, 1 NO AC output • 17.5 mm housing • 60 to 240 V AC output (with back to back SCR) • 5 kV (1.2/50 µs) insulation between Input and 77.01.x.xxx.8051 Output • Zero-crossing and random switch-on versions available • High switching speed • High endurance • Silent switching • Spark and bounce-free switching • Low control power • 3-phase general purpose • 35 mm rail (EN 60715) mount Random switch-on Suggested applications: • Finer control requiring short operate time (specially motor control) • AC Input phase different from AC Output phase Zero-crossing switch-on Suggested applications: • Lamp inrush current reduction (CFL - Compact Fluorescent energy-saving Lamps and similar) • Heater control • Solenoid, contactor driver 77.01 Screw terminal D * See L77-3 diagram page 13 ** See L77-1 and L77-2 diagrams page 12 Simplified circuit diagram For outline drawing see page 16 Output specification Output configuration Rated current IN/Max. peak current* (10 ms) A Simplified circuit diagram 1 NO (SPST-NO) 1 NO (SPST-NO) 5/300* 5/300* Rated voltage  V AC (50/60 Hz) 230 230 Switching voltage range  V AC (50/60 Hz) 48…265 48…265 Repetitive peak off-state voltage  Vpk 800 800 Rated load AC7a (cos ϕ = 0.8)  A 5 5 Rated load AC15  A 5 3 kW — 0.1 1000 800 1000 800 1000 800 800 400 800 400 800 400 1000 100 800 100 0.5 3.5 0.85/1.5 4 0.85/1.5 4 Single phase motor rating (230 V AC)  Nominal lamp rating: 230 V incandescent/halogen W fluorescent tubes with electronic ballast W fluorescent tubes with  electromechanical ballast W CFL W 230 V LED W LV halogen or LED with electronic ballast W LV halogen or LED with electromechanical ballast W Minimum switching current @ 230 V mA Typical “OFF-state” leakage current @ 230 V Max “ON-state” voltage drop @ 25 °C and 5 A/100 mA Power loss @ 5 A  mA V W Input specification Nominal voltage (UN)  Rated power  Operating range  Must drop-out voltage  V AC (50/60 Hz) 24 230 24 V DC 12…24 — 12…24 — VA (50 Hz)/W 0.6/0.5 3.6/0.3 0.6/0.5 3.6/0.3 V AC (50/60 Hz) 16…32 90…265 16…32 90…265 V DC 9.8…32 — 9.8…32 — 2.4 24 2.4 24 V AC (50/60 Hz)/DC 230 Technical data VII-2018, www.findernet.com Electrical life  Operate/release time  Insulation between input and output (1.2/50 µs)  Ambient temperature  Protection category cycles 10 · 106 10 · 106 ms 20/12 9/8 kV °C 5 –20…+70** 5 –20…+70** IP 20 IP 20 Approvals (according to type) 3 77 SERIES 77 SERIES Modular Solid State Relays 7 - 15 A 77.01.9.024.9024 7 - 15 A modular SSR, 1 NO DC output • 17.5 mm housing • 2 versions, for 24 and 125 V DC mosfet output • 4 kV (1.2/50 µs) insulation between Input and 77.01.9.024.9125 Output • Short circuit protection • High switching speed • High endurance • Silent switching • Spark and bounce-free switching • Low control power • Suitable for railway applications • 35 mm rail (EN 60715) mount Applications in Energy, Automation and Machines: • Control of electric, pneumatic and hydraulic electromagnetic valves • Direct control of loads such as motors and electromagnets 77.01 Screw terminal D * See L77-12 and L77-13 diagrams page 12 Applications in Energy, Automation and Machines: • Control of electric, pneumatic and hydraulic electromagnetic valves • Direct control of loads such as motors and electromagnets Simplified circuit diagram For outline drawing see page 16 Output specification Output configuration Rated current IN/Max. peak current (10 ms) 110…125 V DC output switching 7 A rated 24 V DC output switching 15 A rated A Simplified circuit diagram 1 NO (SPST-NO) 1 NO (SPST-NO) 15/160 7/60 Rated voltage  V DC 24 125 Switching voltage range  V DC 16…32 43…140 5 2.5 Rated load DC13 A DC motor rating kW 0.2 — Minimum switching current mA 100 50 3 6 0.06 1 0.2 1.5 6…24 6…24 Typical “OFF-state” leakage current mA Max “ON-state” voltage drop @ 25 °C and INV Power loss @ INW Input specification Nominal voltage (UN) Rated power  V DC W 0.5 0.5 Operating range V DC 4…36 4…36 Must drop-out voltage  V DC 3 3 cycles 10 · 106 10 · 106 ms 0.05/2 0.05/2 kV °C 4 –20…+70* 4 –20…+70* IP 20 IP 20 Technical data Electrical life  Operate/release time  Insulation between input and output (1.2/50 µs)  Ambient temperature  Protection category VII-2018, www.findernet.com Approvals (according to type) 4 77 SERIES Modular Solid State Relays 15 A 77 SERIES 77.11.x.xxx.8250 15 A modular SSR, 1 NO output • 22.5 mm housing, heat-sink + plastic cover • 24 to 277 V AC output (with triac) • 6 kV (1.2/50 µs) insulation between Input and 77.11.x.xxx.8251 Output • Zero-crossing and random switch-on versions available • High switching speed • High endurance • Silent switching • Spark and bounce-free switching • Low control power • 3-phase general purpose • “Relay-style” terminal arrangement (input and output terminals on opposite sides) • 35 mm rail (EN 60715) mount 77.11 Screw terminal Zero-crossing switch-on Suggested applications: • Lamp inrush current reduction (CFL - Compact Fluorescent energy-saving Lamps and similar) • Heater control • Solenoid, contactor driver Random switch-on Suggested applications: • Fine controls involving shorter time (specially motor control) D * See L77-7 diagram page 13 ** See L77-6 diagrams page 12 Simplified circuit diagram For outline drawing see page 16 Output specification Output configuration Rated current IN/Max. peak current* (10 ms)  Simplified circuit diagram 1 NO (SPST-NO) 1 NO (SPST-NO) 15/400* 15/400* A Rated voltage  V AC (50/60 Hz) 230 230 Switching voltage range  V AC (50/60 Hz) 19…305 19…305 Vpk 800 800 Rated load AC7a (cos ϕ = 0.8, @ 25 °C)  Repetitive peak off-state voltage  A 20 20 Rated load AC15  A 15 15 kW — 0.75 4000 2500 4000 2500 2000 3000 1000 1500 230 V LED W LV halogen or LED with electronic ballast W LV halogen or LED with electromechanical ballast W Minimum switching current @ 250 V  mA 3000 1500 3000 1500 3000 100 1500 100 Typical “OFF-state” leakage current @ 250 V  mA Max “ON-state” voltage drop @ 25 °C and 15 A V Power loss @ 15 A W 1 1 1.55 14 1.55 14 Single phase motor rating (230 V AC)  Nominal lamp rating: 230 V incandescent/halogen W fluorescent tubes with electronic ballast W fluorescent tubes with electromechanical ballast W CFL W Input specification Nominal voltage (UN)  Rated power  Operating range  V AC (50/60 Hz) — 230 — V DC 24 — 24 — VA (50 Hz)/W 0.4 7.5/0.9 0.4 7.5/0.9 40…305 V AC (50/60 Hz) V DC Must drop-out voltage  V AC (50/60 Hz)/DC 230 — 40…305 — 4…32 — 4…32 — —/2 6/— —/2 6/— Technical data VII-2018, www.findernet.com Electrical life  Operate/release time  Insulation between input and output (1.2/50 µs)  Ambient temperature  Protection category cycles ms kV °C 10 · 106
77.11.9.024.8250
物料型号: - 77系列固态继电器,包括5A、7-15A、15A、30A、25-40-50A等不同型号。

器件简介: - 77系列固态继电器是模块化的,具有不同的电流和电压规格,适用于多种工业控制应用,如干燥炉、加热和冷却系统、照明控制、瓶装厂、贴标机、包装机等。

引脚分配: - 引脚分配根据具体的固态继电器型号有所不同,但通常包括输入和输出端子,部分型号支持3相通用输入。

参数特性: - 包括额定电流、最大峰值电流、额定电压、开关电压范围、重复峰值关断状态电压、额定负载、最小开关电流、典型关断状态漏电流、最大导通状态电压降等。

功能详解: - 77系列固态继电器具备零交叉和随机开关版本,具有高速开关、高耐用性、无噪音开关、无火花和无反弹切换、低控制功率等特点。

应用信息: - 推荐应用于需要精细控制的场合,如电机控制、加热器控制、电磁阀、接触器驱动等。

封装信息: - 提供了不同尺寸的封装,包括17.5mm、22.5mm等模块化封装,以及“冰球”样式的封装,适用于面板安装或导轨安装。
77.11.9.024.8250 价格&库存

很抱歉,暂时无法提供与“77.11.9.024.8250”相匹配的价格&库存,您可以联系我们找货

免费人工找货
77.11.9.024.8250
  •  国内价格
  • 1+568.81047

库存:40

77.11.9.024.8250
    •  国内价格
    • 1+581.15205
    • 10+487.95672

    库存:21