22.32.0.012.4520

22.32.0.012.4520

  • 厂商:

    FINDER

  • 封装:

  • 描述:

  • 数据手册
  • 价格&库存
22.32.0.012.4520 数据手册
UN (12- 24- 48-60- 120 -230)V AC (50/60 Hz) / DC Umin- Umax (0.8-1.1)UN P 2 VA / 2.2 W ENGLISH 2 1 22.32.0.xxx.xxx0 22.32 MODULAR CONTACTORS 25 A Contact gap ≥ 3 mm for NO contacts only; NC contacts ≥ 1.5 mm. Compliant with EN 61095: 2009. AC/DC silent coil (with varistor protection). 1 CONNECTION DIAGRAM 2 OUTLINE DRAWINGS 22.32...x3x0 22.32...x5x0 3 FRONT VIEW 22.32...x4x0 A = Selector (22.32.0.xxx.xx40) The three-position manual selector has the following functions: 25 A 440 V AC (EN 61095) 22.32 AC1/ AC-7a (250 V) 6250 VA AC3/ AC-7b 10 A AC5a (250 V) 15 A AC15 (230 V AC) 1800 VA M (230 V AC) 1 kW DC1 (30/110/ 220)V (25 /5 /1)A AC-7c (10 A - 22.32...4xx0) 800 W (2000 W - 22.32...4xx0) 300 W (800 W - 22.32...4xx0) CFL–LED 100 W (200 W - 22.32...4xx0) 4 22.32 + (022.33/022.35) AUTO position The state of contacts, mechanical indicator and LED follow the coil supply voltage. OFF position Even if terminals A1 - A2 are supplied with rated voltage, the coil is not energized, and so the contacts remain in the non-operated state, the mechanical indicator is not visible and the LED is not illuminated. (–20...+50)°C B = LED IP20 • Open Type Device - Pollution degree 2 Installation Environment • Maximum Surrounding Air Temperature 50°C • Minimum distance among modular contactors 9 mm • Field Wiring Terminals: Use 60/75°C copper conductor only and wire ranges No. 10-12-18-24 AWG, Solid only Terminal tightening torque 7.0 lb.in. (0.8 Nm) • Suitable for use on a circuit capable of delivering not more than 5000 ARMS Symmetrical, 240 V ac, when protected by Listed Cartridge Fuses, rated K5 Class (No Current Limiting, Non-Time Delay, max 600 Vac, 30 A, 50 kA A.I.C.) or RK5 Class (Current Limiting, Time Delay, max 600 Vac, 15 A, 50 kA A.I.C.) or equivalent • For use in a circuit protected by Type1 or Type2 Surge Protective Devices with “Max Voltage Protection” rating of 3.7 kVpk and “Minimum Nominal Discharge Current” of 5 kA (at 6 kV) Utility Model - IB2232001 - 09/17 - FINDER S.p.A. - 10040 ALMESE (TO) - ITALY ON position The contacts are latched in the operated state (NO contacts closed and NC contacts - open), the mechanical indicator is visible in its window, the LED is not illuminated. 3 022.33 022.35 C = Mechanical indicator 4 ACCESSORIES - Auxiliary contact module available, “Quick assembly” with the main contactor 022.33/022.35 - It is not possible to assembly the auxiliary module on 22.32.0.xxx.x4x0 (2 NC versions) A C B 022.33 2 NO (DPST- NO) 022.35 1 NO (SPST- NO) + 1 NC (SPST- NC) Ith AC15 (230 V AC) 6A 700 VA OTHER DATA It is suggested an air gap of 9 mm between adjacent relays for installations and working conditions close to the limit (that is, ambient temperature > 40°C, coil operated for a prolonged period of time, all contacts loaded with current > 20 A).
22.32.0.012.4520 价格&库存

很抱歉,暂时无法提供与“22.32.0.012.4520”相匹配的价格&库存,您可以联系我们找货

免费人工找货