0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
40.31.9.006.0000

40.31.9.006.0000

  • 厂商:

    FINDER

  • 封装:

  • 描述:

  • 数据手册
  • 价格&库存
40.31.9.006.0000 数据手册
40 Series - Miniature PCB/Plug-in relays 8 - 10 - 16 A Features 40.31 40.51 40.52 1 & 2 Pole relay range 40.31 - 1 Pole 10 A (3.5 mm pin pitch) 40.51 - 1 Pole 10 A (5 mm pin pitch) 40.52 - 2 Pole 8 A (5 mm pin pitch) PCB mount - direct or via PCB socket 35 mm rail mount - via screw and screwless sockets DC coils (standard or sensitive) & AC coils Cadmium Free contact material • 8 mm, 6 kV (1.2/50 µs) isolation, coil-contacts • UL Listing (certain relay/socket combinations) • Flux proof: RT II standard, (RT III option) • 95 series sockets • Coil EMC suppression • Timer accessories 86 series • • FOR UL HORSEPOWER AND PILOT DUTY RATINGS SEE “General technical information” page V 3.5 mm contact pin pitch 1 Pole 10 A • PCB or 95 series sockets 5 mm contact pin pitch 1 Pole 10 A • PCB or 95 series sockets 5 mm contact pin pitch 2 Pole 8 A • PCB or 95 series sockets • • • • • • Copper side view Copper side view Copper side view 1 CO (SPDT) 1 CO (SPDT) 2 CO (DPDT) Contact specification Contact configuration Rated current/Maximum peak current A Rated voltage/Maximum switching voltage V AC 10/20 10/20 8/15 250/400 250/400 250/400 Rated load AC1 VA 2,500 2,500 2,000 Rated load AC15 (230 V AC) VA 500 500 400 kW 0.37 0.37 0.3 10/0.3/0.12 10/0.3/0.12 8/0.3/0.12 300 (5/5) 300 (5/5) 300 (5/5) AgNi AgNi AgNi Single phase motor rating (230 V AC) Breaking capacity DC1: 30/110/220 V Minimum switching load A mW (V/mA) Standard contact material Coil specification Nominal voltage (UN) 6 - 12 - 24 - 48 - 60 - 110 - 120 - 230 - 240 V AC (50/60 Hz) V DC 5 - 6 - 7 - 9 - 12 - 14 - 18 - 21 - 24 - 28 - 36 - 48 - 60 - 90 - 110 - 125 Rated power AC/DC/sens. DC VA (50 Hz)/W/W 1.2/0.65/0.5 1.2/0.65/0.5 1.2/0.65/0.5 Operating range (0.8…1.1)UN (0.8…1.1)UN (0.8…1.1)UN AC DC/sens. DC (0.73…1.5)UN/(0.73…1.75)UN (0.73…1.5)UN/(0.73…1.75)UN (0.73…1.5)UN/(0.73…1.75)UN Holding voltage AC/DC 0.8 UN /0.4 UN 0.8 UN /0.4 UN 0.8 UN /0.4 UN Must drop-out voltage AC/DC 0.2 UN /0.1 UN 0.2 UN /0.1 UN 0.2 UN /0.1 UN Technical data Mechanical life AC/DC cycles 10 · 106/20 · 106 10 · 106/20 · 106 10 · 106/20 · 106 Electrical life at rated load AC1 cycles 200 · 103 200 · 103 100 · 103 7/3 - (12/4 sensitive) 7/3 - (12/4 sensitive) 7/3 - (12/4 sensitive) Insulation between coil and contacts (1.2/50 µs) kV 6 (8 mm) 6 (8 mm) 6 (8 mm) Dielectric strength between open contacts V AC 1,000 1,000 1,000 –40…+85 –40…+85 –40…+85 RT II** RT II** RT II** Operate/release time Ambient temperature range Environmental protection ms °C Approvals (according to type) ** See general technical information “Guidelines for automatic flow solder processes” page II . 1 40 Series - Miniature PCB/Plug-in relays 8 - 10 - 16 A Features 40.61 40.xx.6 40.61 - 1 Pole 16 A (5 mm pin pitch) 40.xx.6 - Bistable versions of the 40.31, 40.51, 40.52 & 40.61 relays PCB mount - direct or via PCB socket 35 mm rail mount - via screw and screwless sockets DC coils & AC coils Cadmium Free option available • 8 mm, 6 kV (1.2/50 µs) isolation, coil-contacts • UL Listing (certain 40.61 relay/socket combinations) • Flux proof: RT II standard, (RT III option) • 95 series sockets • Coil EMC suppression • Timer accessories 86 series • • 5 mm contact pin pitch 1 Pole 16 A • PCB or 95 series sockets • • Bistable (single coil) versions of 40.31/51/52/61 • PCB or 95 series sockets • Bistable version (1 coil) types: 40.31.6... 40.51.6... 40.52.6... 40.61.6... For wiring diagrams see page 8 FOR UL HORSEPOWER AND PILOT DUTY RATINGS SEE “General technical information” page V Copper side view Contact specification Contact configuration 1 CO (SPDT) Rated current/Maximum peak current A Rated voltage/Maximum switching voltage V AC 16/30* 250/400 See relays Rated load AC1 VA 4,000 40.31 Rated load AC15 (230 V AC) VA 750 40.51 0.55 40.52 16/0.3/0.12 40.61 Single phase motor rating (230 V AC) kW Breaking capacity DC1: 30/110/220 V Minimum switching load A mW (V/mA) * With the AgSnO2 material the maximum peak current is 120 A - 5 ms on normally open contact. 500 (10/5) AgCdO Standard contact material Coil specification Nominal voltage (UN) V AC (50/60 Hz) 6 - 12 - 24 - 48 - 60 - 110 - 120 - 230 - 240 5 - 6 - 12 - 24 - 48 - 110 V DC ***See table Rated power AC/DC/sens. DC VA (50 Hz)/W/W 1.2/0.65/0.5 1.0/1.0/— Operating range (0.8…1.1)UN (0.8…1.1)UN AC 5 - 6 - 12 - 24 - 48 - 110 (0.73…1.5)UN/(0.8…1.5)UN (0.8…1.1)UN/— Holding voltage AC/DC 0.8 UN /0.4 UN — Must drop-out voltage AC/DC 0.2 UN /0.1 UN — DC/sens. DC Technical data Mechanical life AC/DC cycles 10 · 106/20 · 106 See relays Electrical life at rated load AC1 cycles 100 · 103 40.31 Operate/release time ms 7/3 - (12/4 sensitive) 40.51 Insulation between coil and contacts (1.2/50 µs) kV 6 (8 mm) 40.52 Dielectric strength between open contacts V AC 1,000 40.61 –40…+85 Min. impulse duration RT II** ≥ 20 ms Ambient temperature range Environmental protection °C Approvals (according to type) 2 ** See general technical information “Guidelines for automatic flow solder processes” page II. *** Nominal voltage (UN): 5 - 6 - 7 - 9 - 12 - 14 - 18 - 21 24 - 28 - 36 - 48 - 60 - 90 110 - 125 V DC 40 Series - Miniature PCB/Plug-in relays 8 - 10 - 16 A Features 40.11 40.11-2016 40.41 1 Pole relay range 40.11 - 1 Pole 10 A (Flat pack) 40.11-2016 - 1 Pole 16 A (Flat pack) 40.41 - 1 Pole 10 A (Vertical) PCB mount - direct or via PCB socket (40.41 version) DC coils Cadmium Free option available • 8 mm, 6 kV (1.2/50 µs) isolation, coil-contacts • 40.41 - NO version available • • 1 Pole 10 A Flat pack • PCB mount 1 Pole 10 A Vertical • PCB or 95 series socket 1 Pole 16 A Flat pack • PCB mount • • • • • • 40.11 40.41 FOR UL HORSEPOWER AND PILOT DUTY RATINGS SEE “General technical information” page V Copper side view Copper side view Copper side view 1 CO (SPDT) 1 CO (SPDT) 1 CO (SPDT) Contact specification Contact configuration Rated current/Maximum peak current A Rated voltage/Maximum switching voltage V AC 10/20 16/30 10/20 250/400 250/400 250/400 Rated load AC1 VA 2,500 4,000 2,500 Rated load AC15 (230 V AC) VA 500 750 500 Single phase motor rating (230 V AC) kW Breaking capacity DC1: 30/110/220 V Minimum switching load A mW (V/mA) Standard contact material 0.37 0.55 0.37 10/0.3/0.12 16/0.3/0.12 10/0.3/0.12 300 (5/5) 500 (10/5) 300 (5/5) AgCdO AgCdO AgCdO Coil specification Nominal voltage (UN) V AC (50/60 Hz) V DC Rated power AC/DC/sens. DC VA (50 Hz)/W/W Operating range AC — — — 6 - 12 - 24 - 48 - 60 6 - 12 - 24 - 48 6 - 12 - 24 - 48 - 60 —/—/0.5 —/—/0.5 —/—/0.5 — — — —/(0.73…1.75)UN —/(0.73…1.5)UN —/(0.73…1.75)UN Holding voltage AC/DC —/0.4 UN —/0.4 UN —/0.4 UN Must drop-out voltage AC/DC —/0.1 UN —/0.1 UN —/0.1 UN Mechanical life AC/DC cycles —/20 · 106 —/20 · 106 —/20 · 106 Electrical life at rated load AC1 cycles 200 · 103 50 · 103 200 · 103 DC/sens. DC Technical data Operate/release time ms 12/4 12/4 12/4 Insulation between coil and contacts (1.2/50 µs) kV 6 (8 mm) 6 (8 mm) 6 (8 mm) Dielectric strength between open contacts V AC 1,000 1,000 1,000 –40…+70 –40…+70 –40…+70 RT I RT I RT I Ambient temperature range Environmental protection °C Approvals (according to type) 3 40 Series - Miniature PCB/Plug-in relays 8 - 10 - 16 A Ordering information Example: 40 series PCB relay, 2 CO (DPDT), 230 V AC coil. A 4 0 . 5 Series Type 1 = PCB 3 = PCB 4 = PCB 5 = PCB 6 = PCB - 3.5 mm pinning, flat 3.5 mm pinning 3.5 mm pinning 5 mm pinning 5 mm pinning No. of poles 1 = 1 pole for: 40.11, 10 A/16 A 40.31, 10 A 40.41, 10 A 40.51, 10 A 40.61, 16 A 2 = 2 pole for: 40.52, 8 A 2 . 8 . 2 3 0 . 0 B C D 0 0 0 A: Contact material 0 = Standard AgNi for 40.31/51/52, AgCdO for 40.61 2 = AgCdO (standard for 40.11/41) 4 = AgSnO2 5 = AgNi + Au (5 µm) D: Special versions 0 = Standard 1 = Wash tight (RT III) 3 = High temperature (+ 125 °C) wash tight C: Options 0 = None 16 = With rated current 16 A (for 40.11) B: Contact circuit 0 = CO (nPDT) 3 = NO (nPST) Coil version 6 = AC/DC bistable 7 = Sensitive DC 8 = AC (50/60 Hz) 9 = DC Coil voltage See coil specifications Selecting features and options: only combinations in the same row are possible. Preferred selections for best availability are shown in bold. Type Coil version A B C D 40.11 sensitive DC 2-4 0 0 0 40.11 sensitive DC 2-4 0 16 / 40.41 sensitive DC 0-2 0-3 0 0 40.31/51 AC-sens. DC 0-2-5 0-3 0 0-1 40.31/51 DC 0-2-5 0-3 0 0-1-3 40.52 AC-sens. DC 0-2-5 0-3 0 0-1 40.52 DC 0-2-5 0-3 0 0-1-3 40.61 AC-sens. DC 0-4 0-3 0 0-1 40.61 DC 0-4 0-3 0 0-1-3 0 0 0 0 40.31/51/ bistable 52/61 4 40 Series - Miniature PCB/Plug-in relays 8 - 10 - 16 A Technical data Insulation according to EN 61810-1 1 pole 2 pole Nominal voltage of supply system V AC 230/400 Rated insulation voltage V AC 250 400 250 400 3 2 3 2 Pollution degree 230/400 Insulation between coil and contact set Type of insulation Overvoltage category Rated impulse voltage kV (1.2/50 µs) Dielectric strength V AC Reinforced (8 mm) Reinforced (8 mm) III III 6 6 4,000 4,000 Insulation between adjacent contacts Type of insulation — Basic Overvoltage category — II kV (1.2/50 µs) — 2.5 V AC — 2,000 Rated impulse voltage Dielectric strength Insulation between open contacts Type of disconnection Micro-disconnection Micro-disconnection 1,000/1.5 1,000/1.5 Burst (5...50)ns, 5 kHz, on A1 - A2 EN 61000-4-4 level 4 (4 kV) Surge (1.2/50 µs) on A1 - A2 (differential mode) EN 61000-4-5 level 3 (2 kV) Dielectric strength V AC/kV (1.2/50 µs) Conducted disturbance immunity Other data Bounce time: NO/NC ms 2/5 Vibration resistance (5…55)Hz: NO/NC g 10/4 (1 changeover) Shock resistance g 13 Power lost to the environment without contact current W 0.6 with rated current W 1.2 (40.11/31/41/51) Recommended distance between relays mounted on PCB mm 15/3 (2 changeover) 2 (40.61/52/40.11-2016) ≥ 5 5 40 Series - Miniature PCB/Plug-in relays 8 - 10 - 16 A Contact specification F 40 - Electrical life (AC) v contact current Type 40.52 Resistive load - cosϕ = 1 Inductive load - cosϕ = 0.4 Cycles Cycles F 40 - Electrical life (AC) v contact current Types 40.31/51/61 Resistive load - cosϕ = 1 Inductive load - cosϕ = 0.4 limit for 40.31/51 Cycles Resistive load - cosϕ = 1 Inductive load - cosϕ = 0.4 limit for version 10 A H 40 - Maximum DC1 breaking capacity DC breaking current (A) F 40 - Electrical life (AC) v contact current Types 40.11/41 40.61 current limit 40.11/31/41/51 current limit 40.52 current limit 40.52 - 2 contacts in series single contact DC voltage (V) • When switching a resistive load (DC1) having voltage and current values under the curve, an electrical life of ≥ 100·103 can be expected. • In the case of DC13 loads, the connection of a diode in parallel with the load will permit a similar electrical life as for a DC1 load. Note: the release time for the load will be increased. 6 40 Series - Miniature PCB/Plug-in relays 8 - 10 - 16 A Coil specifications DC coil data - 0.65 W standard (types 40.31/51/52/61) Nominal voltage UN V 5 6 7 9 12 14 18 21 24 28 36 48 60 90 110 125 Coil code 9.005 9.006 9.007 9.009 9.012 9.014 9.018 9.021 9.024 9.028 9.036 9.048 9.060 9.090 9.110 9.125 Operating range Umin V 3.65 4.4 5.1 6.6 8.8 10.2 13.1 15.3 17.5 20.5 26.3 35 43.8 65.7 80.3 91.2 Umax V 7.5 9 10.5 13.5 18 21 27 31.5 36 42 54 72 90 135 165 188 Resistance Rated coil consumption R I at UN Ω mA 38 130 55 109 75 94 125 72 220 55 300 47 500 36 700 30 900 27 1,200 23 2,000 18 3,500 14 5,500 11 12,500 7.2 18,000 6.2 23,500 5.3 DC coil data - 0.5 W sensitive (types 40.31/51/52/61) Nominal voltage UN V 5 6 7 9 12 14 18 21 24 28 36 48 60 90 110 125 Coil code Operating range Umin* V 3.7 4.4 5.1 6.6 8.8 10.2 13.2 15.4 17.5 20.5 26.3 35 43.8 65.7 80.3 91.2 7.005 7.006 7.007 7.009 7.012 7.014 7.018 7.021 7.024 7.028 7.036 7.048 7.060 7.090 7.110 7.125 *Umin = 0.8 UN for 40.61 Umax** V 8.8 10.5 12.2 15.8 21 24.5 31.5 36.9 42 49 63 84 105 157 192 219 Resistance Rated coil consumption R I at UN Ω mA 50 100 75 80 100 70 160 56 300 40 400 35 650 27.7 900 23.4 1,200 20 1,600 17.5 2,600 13.8 4,800 10 7,200 8.4 16,200 5.6 23,500 4.7 32,000 3.9 **Umax = 1.5 UN for 40.61 DC coil data - 0.5 W sensitive (types 40.11/41) Nominal voltage UN V 6 12 24 48 60 Coil code 7.006 7.012 7.024 7.048 7.060 Operating range Umin V 4.4 8.8 17.5 35 43.8 Umax* V 10.5 21 42 84 105 Resistance Rated coil consumption R I at UN Ω mA 75 80 300 40 1,200 20 4,600 10.4 7,200 8.3 *Umax = 1.5 UN for 40.11-2016 AC/DC coil data - bistable (types 40.31/51/52/61) AC coil data (types 40.31/51/52/61) Nominal voltage UN V 6 12 24 48 60 110 120 230 240 Coil code 8.006 8.012 8.024 8.048 8.060 8.110 8.120 8.230 8.240 Operating range Umin V 4.8 9.6 19.2 38.4 48 88 96 184 192 Umax V 6.6 13.2 26.4 52.8 66 121 132 253 264 Resistance Rated coil consumption R I at UN (50Hz) Ω mA 21 168 80 90 320 45 1,350 21 2,100 16.8 6,900 9.4 9,000 8.4 28,000 5 31,500 4.1 Nominal voltage UN V 5 6 12 24 48 110 Coil code 6.005 6.006 6.012 6.024 6.048 6.110 Operating range Umin V 4 4.8 9.6 19.2 38.4 88 Umax V 5.5 6.6 13.2 26.4 52.8 121 Resistance Rated coil DC: Release consumption resistance** R I at UN RDC Ω mA Ω 23 215 37 33 165 62 130 83 220 520 40 910 2,100 21 3,600 11,000 10 16,500 ** RDC = Resistance in DC, RAC = 1.3 x RDC 1W 7 40 Series - Miniature PCB/Plug-in relays 8 - 10 - 16 A Coil specifications R 40 - DC coil operating range v ambient temperature Standard coil R 40 - DC coil operating range v ambient temperature Sensitive coil, types 40.31/51/52/61 R 40 - DC coil operating range v ambient temperature Sensitive coil, types 40.11/41 R 40 - AC coil operating range v ambient temperature 1 - Max. permitted coil voltage. 2 - Min. pick-up voltage with coil at ambient temperature. 1 - Max. permitted coil voltage. 2 - Min. pick-up voltage with coil at ambient temperature. Wiring diagram for 40 series bistable coil version AC Operation DC Operation On momentary closure of the SET switch the relay is magnetised through the diode and the relay contacts transfer to the set position and remain in this position. On momentary closure of the RESET switch the relay is demagnetised through limiting resistor (RAC) and the contacts return to the reset position. On momentary closure of the SET switch the relay is magnetised and the relay contacts transfer to the set position and remain in this position. On momentary closure of the RESET switch the relay is demagnetised through limiting resistor (RDC) and the contacts return to the reset position. Notes: The minimum SET or RESET impulse time is 20 ms. The maximum time can be continuous. In practice, always ensure that the SET and RESET contacts cannot be operated simultaneously. 8
40.31.9.006.0000 价格&库存

很抱歉,暂时无法提供与“40.31.9.006.0000”相匹配的价格&库存,您可以联系我们找货

免费人工找货