66
SЕRIES
Power relays 30 A
Power
generators
Industrial washing
machines
Burners,
boilers and
furnaces
Industrial
furnaces and
ovens
Air conditioners
Hoists and cranes
Back-up
generators
Industrial
motors
FINDER reserves the right to alter characteristics at any time without notice. FINDER assumes no liability for damage to persons or property, caused as a result of the incorrect use or application of its products.
66 SERIES
Power relays 30 A
66
SERIES
66.22
2 Pole Changeover (DPDT)
30 A Power relay
66.82
Type 66.22
- PCB connections & mount
Type 66.82
- Faston 250 connections and Flange mount
A
• Reinforced insulation between coil and
contacts according to EN 60335-1;
8 mm creepage and clearance distances
• AC coils & DC coils
• Cadmium Free option available
• ATEX compliant (EX nC) option available
• 30 A rated contacts
• PCB mount - bifurcated
terminals
• 30 A rated contacts
• Flange mount
• Faston 250 connections
For outline drawing see page 9
For UL ratings see:
“General technical information” page V
Copper side view
Contact specification
Contact configuration
Rated current/Maximum peak current
Rated voltage/
Maximum switching voltage
A
V AC
2 CO (DPDT)
2 CO (DPDT)
30/50 (NO) - 10/20 (NC)
30/50 (NO) - 10/20 (NC)
250/440
250/440
Rated load AC1
VA
7500 (NO) - 2500 (NC)
7500 (NO) - 2500 (NC)
Rated load AC15 (230 V AC)
VA
1200 (NO)
1200 (NO)
Single phase motor rating (230 V AC)
kW
Breaking capacity DC1: 30/110/220 V
A
Minimum switching load
mW (V/mA)
Standard contact material
1.5 (NO)
1.5 (NO)
25/0.7/0.3 (NO)
25/0.7/0.3 (NO)
1000 (10/10)
1000 (10/10)
AgCdO
AgCdO
Coil specification
Nominal voltage (UN)
V AC (50/60 Hz)
6 - 12 - 24 - 110/115 - 120/125 - 230 - 240
V DC
Rated power AC/DC
Operating range
VA (50 Hz)/W
6 - 9 - 12 - 24 - 110 - 125
3.6/1.7
3.6/1.7
AC
(0.8…1.1)UN
(0.8…1.1)UN
DC
(0.8…1.1)UN
(0.8…1.1)UN
Holding voltage
AC/DC
0.8 UN / 0.5 UN
0.8 UN / 0.5 UN
Must drop-out voltage
AC/DC
0.2 UN / 0.1 UN
0.2 UN / 0.1 UN
Mechanical life AC/DC
cycles
10 · 106
10 · 106
Electrical life at rated load AC1
cycles
100 · 103
100 · 103
ms
8/15
8/15
kV
6 (8 mm)
6 (8 mm)
1500
1500
–40…+70
–40…+70
RT II
RT II
Technical data
II-2019,www.findernet.com
Operate/release time
Insulation between coil
and contacts (1.2/50 µs)
Dielectric strength
between open contacts
Ambient temperature range
Environmental protection
V AC
°C
Approvals (according to type)
3
66
SERIES
66 SERIES
Power relays 30 A
2 Pole NO (DPST-NO)
30 A Power relay
66.22-x30x
66.82-x30x
Type 66.22-x30x
- PCB mount
Type 66.82-x30x
- Faston 250 connections and Flange mount
A
• Reinforced insulation between coil and
•
•
•
contacts according to EN 60335-1;
8 mm creepage and clearance distances
AC coils & DC coils
Cadmium Free option available
ATEX compliant (EX nC) option available
• 30 A rated contacts
• PCB mount - bifurcated
terminals
• 30 A rated contacts
• Flange mount
• Faston 250 connections
For outline drawing see page 9
For UL ratings see:
“General technical information” page V
Copper side view
Contact specification
Contact configuration
Rated current/Maximum peak current
Rated voltage/
Maximum switching voltage
A
V AC
2 NO (DPST-NO)
2 NO (DPST-NO)
30/50
30/50
250/440
250/440
Rated load AC1
VA
7500
7500
Rated load AC15 (230 V AC)
VA
1200
1200
Single phase motor rating (230 V AC)
kW
Breaking capacity DC1: 30/110/220 V
A
Minimum switching load
mW (V/mA)
Standard contact material
1.5
1.5
25/0.7/0.3
25/0.7/0.3
1000 (10/10)
1000 (10/10)
AgCdO
AgCdO
Coil specification
Nominal voltage (UN)
V AC (50/60 Hz)
6 - 12 - 24 - 110/115 - 120/125 - 230 - 240
V DC
Rated power AC/DC
Operating range
VA (50 Hz)/W
6 - 9 - 12 - 24 - 110 - 125
3.6/1.7
3.6/1.7
AC
(0.8…1.1)UN
(0.8…1.1)UN
DC
(0.8…1.1)UN
(0.8…1.1)UN
Holding voltage
AC/DC
0.8 UN / 0.5 UN
0.8 UN / 0.5 UN
Must drop-out voltage
AC/DC
0.2 UN / 0.1 UN
0.2 UN / 0.1 UN
Mechanical life AC/DC
cycles
10 · 106
10 · 106
Electrical life at rated load AC1
cycles
100 · 103
100 · 103
ms
8/10
8/10
kV
6 (8 mm)
6 (8 mm)
1500
1500
–40…+70
–40…+70
RT II
RT II
Operate/release time
Insulation between coil
and contacts (1.2/50 µs)
Dielectric strength
between open contacts
Ambient temperature range
Environmental protection
Approvals (according to type)
4
V AC
°C
II-2019,www.findernet.com
Technical data
66 SERIES
Power relays 30 A
66
SERIES
66.22-x60x
2 Pole NO (DPST-NO), ≥ 1.5 mm contact gap
30 A Power relay
66.22-x60xS
66.82-x60x
Type 66.22-x60x
- PCB mount
Type 66.22-x60xS
- PCB mount, 5 mm gap between PCB and
relay base
Type 66.82-x60x
- Faston 250 connections and Flange mount
A
• PCB mount - bifurcated
• ≥ 1.5 mm contact gap (according to
terminals
VDE 0126-1-1 for solar inverter applications)
• PCB mount - bifurcated
terminals
• 5 mm gap between PCB and
relay base
• Reinforced insulation between coil and
contacts according to EN 60335-1;
8 mm creepage and clearance distances
• Wash tight version (RT III) available
• DC coils
• Cadmium Free option available
• ATEX compliant (EX nC) option available
• Flange mount
• Faston 250 connections
For outline drawing see page 9
For UL ratings see:
“General technical information” page V
Copper side view
Copper side view
2 NO (DPST-NO)
2 NO (DPST-NO)
2 NO (DPST-NO)
30/50
30/50
30/50
250/440
250/440
250/440
Contact specification
Contact configuration
Rated current/Maximum peak current
A
Rated voltage/
Maximum switching voltage
V AC
Rated load AC1
VA
7500
7500
7500
Rated load AC15 (230 V AC)
VA
1200
1200
1200
Single phase motor rating (230 V AC)
kW
Breaking capacity DC1: 30/110/220 V
A
Minimum switching load
mW (V/mA)
Standard contact material
1.5
1.5
1.5
25/1.2/0.5
25/1.2/0.5
25/1.2/0.5
1000 (10/10)
1000 (10/10)
1000 (10/10)
AgCdO
AgCdO
AgCdO
Coil specification
Nominal voltage (UN)
V AC (50/60 Hz)
Rated power AC/DC
VA (50 Hz)/W
—
V DC
Operating range
6 - 9 - 12 - 24 - 110 - 125
—/1.7
—/1.7
—/1.7
AC
—
—
—
DC
(0.8…1.1)UN
(0.7…1.1)UN
(0.8…1.1)UN
Holding voltage
AC/DC
—/0.5 UN
—/0.5 UN
—/0.5 UN
Must drop-out voltage
AC/DC
—/0.1 UN
—/0.1 UN
—/0.1 UN
Mechanical life
cycles
10 · 106
10 · 106
10 · 106
Electrical life at rated load AC1
cycles
100 · 103
100 · 103
100 · 103
ms
15/4
15/4
15/4
kV
6 (8 mm)
6 (8 mm)
6 (8 mm)
2500
2500
2500
–40…+70
–40…+70
–40…+70
RT II
RT II
RT II
Technical data
II-2019,www.findernet.com
Operate/release time
Insulation between coil
and contacts (1.2/50 µs)
Dielectric strength
between open contacts
Ambient temperature range
Environmental protection
V AC
°C
Approvals (according to type)
5
66 SERIES
Power relays 30 A
66
SERIES
Ordering information
Example: 66 series relay, Faston 250 (6.3x0.8 mm) with top flange mount, 2 CO (DPDT) 30 A contacts, 24 V DC coil.
A
6 6 . 8
A
B
C
D
2 . 9 . 0 2 4 . 0
0
0
0
A: Contact material
0 = Standard AgCdO
1 = AgNi
Series
Type
2 = PCB
8 = Faston 250 (6.3 x 0.8 mm)
with top flange mount
S=P
CB version with
5 mm gap
between PCB and
relay base
(only 66.22)
B: Contact circuit
0 = CO (nPDT)
3 = NO (nPST)
6 = NO (nPST), ≥ 1.5 mm
contact gap
No. of poles
2 = 2 pole 30 A (versions 0, 1)
2 = 2 pole 25 A (version 3)
D: Special versions
0 = Standard
1 = Wash tight (RT III)
3 = ATEX compliant (Ex nC)
Coil version
8 = AC (50/60 Hz)
9 = DC
C: Options
0 = None
Coil voltage
See coil specifications
Selecting features and options: only combinations in the same row are possible.
Preferred selections for best availability are shown in bold.
Type
66.22
66.22….S
66.82
Coil version
AC-DC
DC
DC
AC-DC
DC
A
0-1
0-1
0-1
0-1
0-1
B
0-3
6
6
0-3
6
C
0
0
0
0
0
D
0-1
0-1
0-1-3
0-1-3
0-1-3
Technical data
Insulation according to EN 61810-1
Nominal voltage of supply system
V AC 230/400
Rated insulation voltage
V AC 400
Pollution degree
3
Insulation between coil and contact set
Type of insulation
Reinforced (8 mm)
Overvoltage category
III
Rated impulse voltage
kV (1.2/50 µs) 6
Dielectric strength
V AC 4000
Insulation between adjacent contacts
Type of insulation
Basic
Overvoltage category
III
Rated impulse voltage
kV (1.2/50 µs) 4
Dielectric strength
V AC 2500
Insulation between open contacts
2 CO
2 NO, ≥ 1.5 mm (x60x version)
Type of disconnection
Micro-disconnection
Full-disconnection*
Overvoltage category
—
II
Rated impulse voltage
kV (1.2/50 µs) —
Dielectric strength
V AC/kV (1.2/50 µs) 1500/2
2.5
2500/2.5
Insulation between coil terminals
Rated impulse voltage (surge) differential mode
(according to EN 61000-4-5)
kV(1.2/50 µs) 4
Other data
ms 7/10
Vibration resistance (10…150)Hz: NO/NC
g 20/19
Shock resistance
g 20
Power lost to the environment
without contact current
with rated current
Recommended distance between relays mounted on PCB
W 2.3
W 5
mm ≥ 10
* Only in applications where over voltage category II is permitted. In applications of over voltage category III: Micro-disconnection.
6
II-2019,www.findernet.com
Bounce time: NO/NC
66 SERIES
Power relays 30 A
66
SERIES
Contact specification
F 66 - Electrical life (AC) v contact current
440 V (normally open contact)
Cycles
Resistive load - 250 V AC cosϕ = 1
Inductive load - 250 V AC cosϕ = 0.4
DC breaking current (A)
H 66 - Maximum DC breaking capacity, x60x versions
(> 1.5 mm contact gap)
DC breaking current (A)
H 66 - Maximum DC breaking capacity
A
Resistive load - 440 V AC cosϕ = 1
Inductive load - 440 V AC cosϕ = 0.4
Cycles
F 66 - Electrical life (AC) v contact current
250 V (normally open contact)
DC voltage (V)
DC voltage (V)
• When switching a resistive load (DC1) having voltage and current values under the curve, an electrical life of ≥ 100 · 103 can be expected.
• In the case of DC13 loads, the connection of a diode in parallel with the load will permit a similar electrical life as for a DC1 load.
Note: the release time for the load will be increased.
Coil specifications
DC coil data
Nominal
voltage
II-2019,www.findernet.com
UN
V
6
9
12
24
110
125
AC coil data
Coil
code
9.006
9.009
9.012
9.024
9.110
9.125
Operating range
Umin
V
4.8
7.2
9.6
19.2
88
100
Umax
V
6.6
9.9
13.2
26.4
121
138
Resistance
Rated coil
Consumption
R
Ω
21
45
85
340
7000
9200
I at UN
mA
283
200
141
70.5
15.7
13.6
Nominal
voltage
UN
V
6
12
24
110/115
120/125
230
240
Coil
code
8.006
8.012
8.024
8.110
8.120
8.230
8.240
Operating range
Umin
V
4.8
9.6
19.2
88
96
184
192
Umax
V
6.6
13.2
26.4
126
137
253
264
Resistance
Rated coil
Consumption
R
Ω
I at UN (50 Hz)
mA
600
300
150
32.6
30
15.7
15
3
11
50
930
1050
4000
5500
R 66 - DC coil operating range v ambient temperature
R 66 - AC coil operating range v ambient temperature
1 - Max. permitted coil voltage.
2 - Min. pick-up voltage with coil at ambient temperature.
3 - Min. pick-up voltage with coil at ambient temperature (66.22-x60xS)
1 - Max. permitted coil voltage.
2 - Min. pick-up voltage with coil at ambient temperature.
7
66
SERIES
66 SERIES
Power relays 30 A
Features compliant variant ATEX, II 3G Ex nC IIC Gc
MARKING
Specific marking of explosion protection
II
Component for surface plant (different from mines)
3
Category 3: normal level of protection
G
Explosive atmosphere due to presence of combustible gas vapour or mist
Ex nC
Sealed device (type of protection for category 3G)
IIC
Gas group
Gc
Equipment Protection Level
–40 °C ≤ Ta ≤ +70 °C
Ambient temperature
EUT 14 ATEX 0150 U
EUT: laboratory which issues the CE type certificate
14: year of issue of certificate
0150: number of CE type certificate
U: ATEX component
GAS
Electrical characteristics
Characteristics of terminals
Rated current/Maximum peak current
Rated voltage/Maximum switching voltage
Rated load AC1
A 25/50 (NO) - 10/20 (NC)
V AC 250/400
VA 6250 (NO) - 2500 (NC)
Rated load AC15
VA 1200 (NO)
Capacity for single phase motor (230 V AC)
kW 1.5 (NO)
Breaking capacity DC1: 30/110/220 V
A 25/0.7/0.3 (NO)
Characteristics of coil
Rated voltage (UN)
V AC (50/60 Hz) 6 - 12 - 24 - 110/115 - 120/125 - 230 - 240
V DC 6 - 12 - 24 - 110 - 125
Rated Power AC/DC
Operating range
VA (50 Hz)/W 3.6/1.7
AC/DC (0.8…1.1)UN
General characteristics
Ambient temperature
°C –40…+70
Special condition for safe use
The component must be placed inside an enclosure that meets the general requirements for enclosures as per clause 6.3 of EN 60079-15.
The connections must be made in compliance with the requirements of clause 7.2.4 or 7.2.5 of EN 60079-15.
Wiring
The cross-section of conductors connected to the terminals, must be at least 4 mm2 for the Type 66.82.
Layout pcb
The minimum cross-section of the tracks of the printed circuit board must be 0.58 mm2, while the width must be at least 4 mm for Types “66.22” and
“66.22….S”.
II-2019,www.findernet.com
A
8
66 SERIES
Power relays 30 A
66
SERIES
Outline drawings
Type 66.22
Type 66.82
A
Type 66.22-0300
Type 66.82-0300
Type 66.22-0600
Type 66.82-0600
Type 66.22-0600S
Accessories
Top 35 mm rail (EN 60715) mount for types 66.82.xxxx.0x00
066.07
II-2019,www.findernet.com
066.07
066.07 with relay
066.07
Please see general technical information
066.07 with relay
9