0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
662290240600

662290240600

  • 厂商:

    FINDER

  • 封装:

  • 描述:

    FINDER - 662290240600 - Power Relay, DPST-NO, 24 VDC, 30 A, 66 Series, Through Hole

  • 数据手册
  • 价格&库存
662290240600 数据手册
66 SЕRIES Power relays 30 A Power generators Industrial washing machines Burners, boilers and furnaces Industrial furnaces and ovens Air conditioners Hoists and cranes Back-up generators Industrial motors FINDER reserves the right to alter characteristics at any time without notice. FINDER assumes no liability for damage to persons or property, caused as a result of the incorrect use or application of its products. 66 SERIES Power relays 30 A 66 SERIES 66.22 2 Pole Changeover (DPDT) 30 A Power relay 66.82 Type 66.22 - PCB connections & mount Type 66.82 - Faston 250 connections and Flange mount A • Reinforced insulation between coil and contacts according to EN 60335-1; 8 mm creepage and clearance distances • AC coils & DC coils • Cadmium Free option available • ATEX compliant (EX nC) option available • 30 A rated contacts • PCB mount - bifurcated terminals • 30 A rated contacts • Flange mount • Faston 250 connections For outline drawing see page 9 For UL ratings see: “General technical information” page V Copper side view Contact specification Contact configuration Rated current/Maximum peak current Rated voltage/ Maximum switching voltage A V AC 2 CO (DPDT) 2 CO (DPDT) 30/50 (NO) - 10/20 (NC) 30/50 (NO) - 10/20 (NC) 250/440 250/440 Rated load AC1 VA 7500 (NO) - 2500 (NC) 7500 (NO) - 2500 (NC) Rated load AC15 (230 V AC) VA 1200 (NO) 1200 (NO) Single phase motor rating (230 V AC) kW Breaking capacity DC1: 30/110/220 V A Minimum switching load mW (V/mA) Standard contact material 1.5 (NO) 1.5 (NO) 25/0.7/0.3 (NO) 25/0.7/0.3 (NO) 1000 (10/10) 1000 (10/10) AgCdO AgCdO Coil specification Nominal voltage (UN) V AC (50/60 Hz) 6 - 12 - 24 - 110/115 - 120/125 - 230 - 240 V DC Rated power AC/DC Operating range VA (50 Hz)/W 6 - 9 - 12 - 24 - 110 - 125 3.6/1.7 3.6/1.7 AC (0.8…1.1)UN (0.8…1.1)UN DC (0.8…1.1)UN (0.8…1.1)UN Holding voltage AC/DC 0.8 UN / 0.5 UN 0.8 UN / 0.5 UN Must drop-out voltage AC/DC 0.2 UN / 0.1 UN 0.2 UN / 0.1 UN Mechanical life AC/DC cycles 10 · 106 10 · 106 Electrical life at rated load AC1 cycles 100 · 103 100 · 103 ms 8/15 8/15 kV 6 (8 mm) 6 (8 mm) 1500 1500 –40…+70 –40…+70 RT II RT II Technical data II-2019,www.findernet.com Operate/release time Insulation between coil and contacts (1.2/50 µs) Dielectric strength between open contacts Ambient temperature range Environmental protection V AC °C Approvals (according to type) 3 66 SERIES 66 SERIES Power relays 30 A 2 Pole NO (DPST-NO) 30 A Power relay 66.22-x30x 66.82-x30x Type 66.22-x30x - PCB mount Type 66.82-x30x - Faston 250 connections and Flange mount A • Reinforced insulation between coil and • • • contacts according to EN 60335-1; 8 mm creepage and clearance distances AC coils & DC coils Cadmium Free option available ATEX compliant (EX nC) option available • 30 A rated contacts • PCB mount - bifurcated terminals • 30 A rated contacts • Flange mount • Faston 250 connections For outline drawing see page 9 For UL ratings see: “General technical information” page V Copper side view Contact specification Contact configuration Rated current/Maximum peak current Rated voltage/ Maximum switching voltage A V AC 2 NO (DPST-NO) 2 NO (DPST-NO) 30/50 30/50 250/440 250/440 Rated load AC1 VA 7500 7500 Rated load AC15 (230 V AC) VA 1200 1200 Single phase motor rating (230 V AC) kW Breaking capacity DC1: 30/110/220 V A Minimum switching load mW (V/mA) Standard contact material 1.5 1.5 25/0.7/0.3 25/0.7/0.3 1000 (10/10) 1000 (10/10) AgCdO AgCdO Coil specification Nominal voltage (UN) V AC (50/60 Hz) 6 - 12 - 24 - 110/115 - 120/125 - 230 - 240 V DC Rated power AC/DC Operating range VA (50 Hz)/W 6 - 9 - 12 - 24 - 110 - 125 3.6/1.7 3.6/1.7 AC (0.8…1.1)UN (0.8…1.1)UN DC (0.8…1.1)UN (0.8…1.1)UN Holding voltage AC/DC 0.8 UN / 0.5 UN 0.8 UN / 0.5 UN Must drop-out voltage AC/DC 0.2 UN / 0.1 UN 0.2 UN / 0.1 UN Mechanical life AC/DC cycles 10 · 106 10 · 106 Electrical life at rated load AC1 cycles 100 · 103 100 · 103 ms 8/10 8/10 kV 6 (8 mm) 6 (8 mm) 1500 1500 –40…+70 –40…+70 RT II RT II Operate/release time Insulation between coil and contacts (1.2/50 µs) Dielectric strength between open contacts Ambient temperature range Environmental protection Approvals (according to type) 4 V AC °C II-2019,www.findernet.com Technical data 66 SERIES Power relays 30 A 66 SERIES 66.22-x60x 2 Pole NO (DPST-NO), ≥ 1.5 mm contact gap 30 A Power relay 66.22-x60xS 66.82-x60x Type 66.22-x60x - PCB mount Type 66.22-x60xS - PCB mount, 5 mm gap between PCB and relay base Type 66.82-x60x - Faston 250 connections and Flange mount A • PCB mount - bifurcated • ≥ 1.5 mm contact gap (according to terminals VDE 0126-1-1 for solar inverter applications) • PCB mount - bifurcated terminals • 5 mm gap between PCB and relay base • Reinforced insulation between coil and contacts according to EN 60335-1; 8 mm creepage and clearance distances • Wash tight version (RT III) available • DC coils • Cadmium Free option available • ATEX compliant (EX nC) option available • Flange mount • Faston 250 connections For outline drawing see page 9 For UL ratings see: “General technical information” page V Copper side view Copper side view 2 NO (DPST-NO) 2 NO (DPST-NO) 2 NO (DPST-NO) 30/50 30/50 30/50 250/440 250/440 250/440 Contact specification Contact configuration Rated current/Maximum peak current A Rated voltage/ Maximum switching voltage V AC Rated load AC1 VA 7500 7500 7500 Rated load AC15 (230 V AC) VA 1200 1200 1200 Single phase motor rating (230 V AC) kW Breaking capacity DC1: 30/110/220 V A Minimum switching load mW (V/mA) Standard contact material 1.5 1.5 1.5 25/1.2/0.5 25/1.2/0.5 25/1.2/0.5 1000 (10/10) 1000 (10/10) 1000 (10/10) AgCdO AgCdO AgCdO Coil specification Nominal voltage (UN) V AC (50/60 Hz) Rated power AC/DC VA (50 Hz)/W — V DC Operating range 6 - 9 - 12 - 24 - 110 - 125 —/1.7 —/1.7 —/1.7 AC — — — DC (0.8…1.1)UN (0.7…1.1)UN (0.8…1.1)UN Holding voltage AC/DC —/0.5 UN —/0.5 UN —/0.5 UN Must drop-out voltage AC/DC —/0.1 UN —/0.1 UN —/0.1 UN Mechanical life cycles 10 · 106 10 · 106 10 · 106 Electrical life at rated load AC1 cycles 100 · 103 100 · 103 100 · 103 ms 15/4 15/4 15/4 kV 6 (8 mm) 6 (8 mm) 6 (8 mm) 2500 2500 2500 –40…+70 –40…+70 –40…+70 RT II RT II RT II Technical data II-2019,www.findernet.com Operate/release time  Insulation between coil and contacts (1.2/50 µs) Dielectric strength between open contacts Ambient temperature range Environmental protection V AC °C Approvals (according to type) 5 66 SERIES Power relays 30 A 66 SERIES Ordering information Example: 66 series relay, Faston 250 (6.3x0.8 mm) with top flange mount, 2 CO (DPDT) 30 A contacts, 24 V DC coil. A 6 6 . 8 A B C D 2 . 9 . 0 2 4 . 0 0 0 0 A: Contact material 0 = Standard AgCdO 1 = AgNi Series Type 2 = PCB 8 = Faston 250 (6.3 x 0.8 mm) with top flange mount S=P  CB version with 5 mm gap between PCB and relay base (only 66.22) B: Contact circuit 0 = CO (nPDT) 3 = NO (nPST) 6 = NO (nPST), ≥ 1.5 mm contact gap No. of poles 2 = 2 pole 30 A (versions 0, 1) 2 = 2 pole 25 A (version 3) D: Special versions 0 = Standard 1 = Wash tight (RT III) 3 = ATEX compliant (Ex nC) Coil version 8 = AC (50/60 Hz) 9 = DC C: Options 0 = None Coil voltage See coil specifications Selecting features and options: only combinations in the same row are possible. Preferred selections for best availability are shown in bold. Type 66.22 66.22….S 66.82 Coil version AC-DC DC DC AC-DC DC A 0-1 0-1 0-1 0-1 0-1 B 0-3 6 6 0-3 6 C 0 0 0 0 0 D 0-1 0-1 0-1-3 0-1-3 0-1-3 Technical data Insulation according to EN 61810-1 Nominal voltage of supply system V AC 230/400 Rated insulation voltage V AC 400 Pollution degree 3 Insulation between coil and contact set Type of insulation Reinforced (8 mm) Overvoltage category III Rated impulse voltage kV (1.2/50 µs) 6 Dielectric strength V AC 4000 Insulation between adjacent contacts Type of insulation Basic Overvoltage category III Rated impulse voltage kV (1.2/50 µs) 4 Dielectric strength V AC 2500 Insulation between open contacts 2 CO 2 NO, ≥ 1.5 mm (x60x version) Type of disconnection Micro-disconnection Full-disconnection* Overvoltage category — II Rated impulse voltage kV (1.2/50 µs) — Dielectric strength V AC/kV (1.2/50 µs) 1500/2 2.5 2500/2.5 Insulation between coil terminals Rated impulse voltage (surge) differential mode (according to EN 61000-4-5) kV(1.2/50 µs) 4 Other data ms 7/10 Vibration resistance (10…150)Hz: NO/NC g 20/19 Shock resistance g 20 Power lost to the environment without contact current with rated current Recommended distance between relays mounted on PCB  W 2.3 W 5 mm ≥ 10 * Only in applications where over voltage category II is permitted. In applications of over voltage category III: Micro-disconnection. 6 II-2019,www.findernet.com Bounce time: NO/NC 66 SERIES Power relays 30 A 66 SERIES Contact specification F 66 - Electrical life (AC) v contact current 440 V (normally open contact) Cycles Resistive load - 250 V AC cosϕ = 1 Inductive load - 250 V AC cosϕ = 0.4 DC breaking current (A) H 66 - Maximum DC breaking capacity, x60x versions (> 1.5 mm contact gap) DC breaking current (A) H 66 - Maximum DC breaking capacity A Resistive load - 440 V AC cosϕ = 1 Inductive load - 440 V AC cosϕ = 0.4 Cycles F 66 - Electrical life (AC) v contact current 250 V (normally open contact) DC voltage (V) DC voltage (V) • When switching a resistive load (DC1) having voltage and current values under the curve, an electrical life of ≥ 100 · 103 can be expected. • In the case of DC13 loads, the connection of a diode in parallel with the load will permit a similar electrical life as for a DC1 load. Note: the release time for the load will be increased. Coil specifications DC coil data Nominal voltage II-2019,www.findernet.com UN V 6 9 12 24 110 125 AC coil data Coil code 9.006 9.009 9.012 9.024 9.110 9.125 Operating range Umin V 4.8 7.2 9.6 19.2 88 100 Umax V 6.6 9.9 13.2 26.4 121 138 Resistance Rated coil Consumption R Ω 21 45 85 340 7000 9200 I at UN mA 283 200 141 70.5 15.7 13.6 Nominal voltage UN V 6 12 24 110/115 120/125 230 240 Coil code 8.006 8.012 8.024 8.110 8.120 8.230 8.240 Operating range Umin V 4.8 9.6 19.2 88 96 184 192 Umax V 6.6 13.2 26.4 126 137 253 264 Resistance Rated coil Consumption R Ω I at UN (50 Hz) mA 600 300 150 32.6 30 15.7 15 3 11 50 930 1050 4000 5500 R 66 - DC coil operating range v ambient temperature R 66 - AC coil operating range v ambient temperature 1 - Max. permitted coil voltage. 2 - Min. pick-up voltage with coil at ambient temperature. 3 - Min. pick-up voltage with coil at ambient temperature (66.22-x60xS) 1 - Max. permitted coil voltage. 2 - Min. pick-up voltage with coil at ambient temperature. 7 66 SERIES 66 SERIES Power relays 30 A Features compliant variant ATEX, II 3G Ex nC IIC Gc MARKING Specific marking of explosion protection II Component for surface plant (different from mines) 3 Category 3: normal level of protection G Explosive atmosphere due to presence of combustible gas vapour or mist Ex nC Sealed device (type of protection for category 3G) IIC Gas group Gc Equipment Protection Level –40 °C ≤ Ta ≤ +70 °C Ambient temperature EUT 14 ATEX 0150 U EUT: laboratory which issues the CE type certificate 14: year of issue of certificate 0150: number of CE type certificate U: ATEX component GAS Electrical characteristics Characteristics of terminals Rated current/Maximum peak current Rated voltage/Maximum switching voltage Rated load AC1 A 25/50 (NO) - 10/20 (NC) V AC 250/400 VA 6250 (NO) - 2500 (NC) Rated load AC15 VA 1200 (NO) Capacity for single phase motor (230 V AC) kW 1.5 (NO) Breaking capacity DC1: 30/110/220 V A 25/0.7/0.3 (NO) Characteristics of coil Rated voltage (UN) V AC (50/60 Hz) 6 - 12 - 24 - 110/115 - 120/125 - 230 - 240 V DC 6 - 12 - 24 - 110 - 125 Rated Power AC/DC Operating range  VA (50 Hz)/W 3.6/1.7 AC/DC (0.8…1.1)UN General characteristics Ambient temperature °C –40…+70 Special condition for safe use The component must be placed inside an enclosure that meets the general requirements for enclosures as per clause 6.3 of EN 60079-15. The connections must be made in compliance with the requirements of clause 7.2.4 or 7.2.5 of EN 60079-15. Wiring The cross-section of conductors connected to the terminals, must be at least 4 mm2 for the Type 66.82. Layout pcb The minimum cross-section of the tracks of the printed circuit board must be 0.58 mm2, while the width must be at least 4 mm for Types “66.22” and “66.22….S”. II-2019,www.findernet.com A 8 66 SERIES Power relays 30 A 66 SERIES Outline drawings Type 66.22 Type 66.82 A Type 66.22-0300 Type 66.82-0300 Type 66.22-0600 Type 66.82-0600 Type 66.22-0600S Accessories Top 35 mm rail (EN 60715) mount for types 66.82.xxxx.0x00 066.07 II-2019,www.findernet.com 066.07 066.07 with relay 066.07 Please see general technical information 066.07 with relay 9
662290240600 价格&库存

很抱歉,暂时无法提供与“662290240600”相匹配的价格&库存,您可以联系我们找货

免费人工找货