0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
7S.14.8.230.4220

7S.14.8.230.4220

  • 厂商:

    FINDER

  • 封装:

  • 描述:

    SFTY RLY GUIDE 2NO+2NC 6A 230VAC

  • 详情介绍
  • 数据手册
  • 价格&库存
7S.14.8.230.4220 数据手册
Modular relays with forcibly guided contacts 6 - 10 A Chemical and petrolchemical Hoists and cranes Woodprocessing machines Carousel warehouses Escalators Elevators and lifts Process Industry Automatic car-washes 7S SЕRIES FINDER reserves the right to alter characteristics at any time without notice. FINDER assumes no liability for damage to persons or property, caused as a result of the incorrect use or application of its products. 7S 7S SERIES Modular relays with forcibly guided contacts 6 A 7S.12/32....5110 Modular relays with forcibly guided contacts SERIES 7S.14/34....4xx0 7S.16/36....5xx0 Type 7S.12/32 - 2 pole 6 A (1 NO + 1 NC) Type 7S.14/34 - 4 pole 6 A (2 NO + 2 NC and 3 NO + 1 NC) Type 7S.16/36 - 6 pole 6 A (4 NO + 2 NC and 5 NO + 1 NC) • For safety applications, with class A forcibly guided contact relays EN 61810-3 (previously EN 50205) • SIL2 evaluated according to EN 61508, for use in functional safety application according to EN 62061 up to SIL2 and according to IEC 13849-1 up to PL d (instead of For functional reliability in machinery and plant engineering according to EN 13849-1) • For functional reliability in machinery and plant engineering according to EN 13849-1 • For railway applications; materials compliant with fire and smoke characteristics EN 45545; mechanical and climatic characteristics compliant with EN 61373 and EN 50155 • DC and AC supply versions • 24 and 110 V DC versions with extended operating range (0.7…1.25)UN • Coil status visual indication with LED • 35 mm rail (EN 60715) mount Screwless terminal • 2 pole (1 NO + 1 NC) • 4 pole : • 6 pole: (2 NO + 2 NC) type 7S.xx.x.xxx.4220 (3 NO + 1 NC) type 7S.xx.x.xxx.4310 (4 NO + 2 NC) type 7S.xx.x.xxx.5420 (5 NO + 1 NC) type 7S.xx.x.xxx.5510 C Screw terminal For outline drawing see page 12 Contact specification Contact configuration Rated current/Max. peak current Rated switching voltage A 1 NO + 1 NC 2 NO + 2 NC, 3 NO + 1 NC 4 NO + 2 NC 6/15 6/15 6/15 V AC (50/60 Hz) 250 250 250 VA 1500 1500 1500 Rated current AC15 (230 V AC) A 5 5 5 Rated current AC15 (400 V AC) A 2 — — Breaking capacity DC1: 30/110/220 V A 6/0.6/0.2 6/0.9/0.3 6/0.9/0.3 Rated load AC1 Breaking capacity DC13: 24 V Minimum switching load A mW (V/mA) Standard contact material 1 3 3 60 (5/5) 60 (5/10) 60 (5/10) AgNi + Au AgSnO2 AgSnO2+Au 110…125 - 230…240 110…125 - 230…240 110…125 - 230…240 12 - 24 12 - 24 - 110 12 - 24 - 110 Coil specification Nominal voltage (UN) V AC (50/60 Hz) V DC Rated power Operating range VA (50 Hz)/W AC 2.3/1 2.3/1 2.3/1 (0.85…1.1)UN (0.85…1.1)UN (0.85…1.1)UN DC (0.8…1.2)UN (0.8…1.2)UN (0.8…1.2)UN DC extended range (24 and 110 V only) (0.7…1.25)UN (0.7…1.25)UN (0.7…1.25)UN Holding voltage AC/DC 0.45 UN / 0.45 UN 0.55 UN / 0.55 UN 0.55 UN / 0.55 UN Must drop-out voltage AC/DC 0.1 UN / 0.1 UN 0.1 UN / 0.1 UN 0.1 UN / 0.1 UN Mechanical life cycles 10 · 106 10 · 106 10 · 106 Electrical life at rated load AC1 cycles 100 · 10 100 · 10 100 · 103 7/11 12/10 12/10 6 6 6 Technical data VII-2022, www.findernet.com Operate/release time ms Insulation between coil and contacts (1.2/50 µs) kV Dielectric strength between open contacts V AC Ambient temperature Protection category °C 3 3 1500 1500 1500 –40…+70 –40…+70 –40…+70 IP 20 IP 20 IP 20 Approvals (according to type) 3 7S SERIES 7S SERIES Modular relays with forcibly guided contacts 10 A Modular relays with forcibly guided contacts 7S.23 Type 7S.23 - 3 pole (2 NO + 1 NC) • For safety applications, with class A forcibly • 3 pole (2 NO + 1 NC) Screw terminal For outline drawing see page 12 Contact specification Contact configuration 2 NO + 1 NC Rated current/Max. peak current Rated switching voltage A 10/20 V AC (50/60 Hz) 250 VA 2500 Rated current AC15 (230 V AC) A 5 Breaking capacity DC1: 30/110/220 V A 10/0.6/0.3 Breaking capacity DC13: 24 V A 5 Rated load AC1 Minimum switching load mW (V/mA) Standard contact material 60 (5/5) AgNi + Au Coil specification Nominal voltage (UN) Rated power V DC 12 - 24 - 48 -110 W 1 Operating range DC (0.8…1.2)UN Holding voltage DC 0.45 UN Must drop-out voltage DC 0.1 UN Mechanical life cycles 10 · 106 Electrical life at rated load AC1 cycles 100 · 103 Technical data Operate/release time ms Insulation between coil and contacts (1.2/50 µs) kV Dielectric strength between open contacts V AC Ambient temperature Protection category Approvals (according to type) 4 °C 7/11 6 1500 –40…+70 IP 20 VII-2022, www.findernet.com C guided contact relays EN 61810-3 (previously EN 50205) • SIL2 evaluated according to EN 61508, for use in functional safety application according to EN 62061 up to SIL2 and according to IEC 13849-1 up to PL d (instead of For functional reliability in machinery and plant engineering according to EN 13849-1) • For functional reliability in machinery and plant engineering according to EN 13849-1 • DC coil • Cadmium free contacts • 17.5 mm wide • Coil status visual indication with LED • 35 mm rail (EN 60715) mount 7S SERIES Modular relays with forcibly guided contacts 6 A Modular relays with forcibly guided contacts for SIL3 safety applications 7S.43/63....0211 Type 7S.43/63 -2 NO safety contacts - 1 NC feedback contact - 1 auxiliary signalling contact • For safety application, with class A forcibly guided contact relays EN 61810-3 (previously EN 50205) for safety application up to SIL 3 • SIL 3 evaluated according to EN 61508, for use in functional safety application according to EN 62061 up to SIL 3 and according to IEC 13849-1 up to PL e • Double channel architecture (1oo2) with 2 NO contact, 1 feedback contact and 1 auxiliary contact • From 12 up to 110 V DC version with operating range (0.85…1.1)UN • DC coil • Coil status visual indication with LED • 35 mm rail (EN 60715) mount Screwless terminal 7S SERIES • 3 pole (2 NO + 1 NC) • 1 auxliary contact C Screw terminal For outline drawing see page 12 Contact specification Contact configuration 2 NO + 1 NC + 1 AUX Rated current/Max. peak current Rated switching voltage A 6/15 V AC (50/60 Hz) 250 VA 1500 Rated load AC1 Rated current AC15 (230 V AC) A 5 Breaking capacity DC1: 30/110/220 V A 6/0.6/0.2 Breaking capacity DC13: 24 V Minimum switching load A mW (V/mA) 3 60 (5/10) AgSnO2 & AgNi+Au Standard contact material Coil specification Nominal voltage (UN) Rated power V DC 12 - 24 - 48 -110 W 1.7 Operating range DC (0.85…1.1)UN Holding voltage DC 0.55 UN Must drop-out voltage DC 0.1 UN Mechanical life cycles 10 · 106 Electrical life at rated load AC1 cycles 100 · 103 VII-2022, www.findernet.com Technical data Operate/release time of NO contacts ms 10/7 Operate/release time of NC contacts ms 5/30 Insulation between coil and contacts (1.2/50 µs) kV Dielectric strength between open contacts V AC Ambient temperature Protection category °C 6 1500 –40…+70 IP 20 Approvals (according to type) 5 7S SERIES 7S SERIES Modular relays with forcibly guided contacts 6 - 10 A Ordering information Example: 7S series Modular relay with forcibly guided contacts, 6 contact (4 NO + 2 NC) 6 A, supply voltage 24 V DC. 7 S . 1 6 . 9 . 0 2 4 . 5 4 2 Special versions 0 = Standard 1 = NO auxliary contact Series Type 1 = 22.5 mm wide, screwless terminals 2 = 17.5 mm wide, screw terminals 3 = 22.5 mm wide, screw terminals 4 = 22.5 mm wide, screwless terminals 6 = 22.5 mm wide, screw terminals C 0 NO and NC contatcs 11 = 1 NO + 1 NC (SPST-NO + SPST-NC) 21 = 2 NO + 1 NC (DPST-NO+SPST-NC) 22 = 2 NO + 2 NC (DPST-NO + DPST-NC) 31 = 3 NO + 1 NC (3PST-NO + SPST-NC) 42 = 4 NO + 2 NC (4PST-NO + DPST-NC) 51 = 5 NO + 1 NC (4PST-NO + SPST-NC) Output 2 = 2 contacts 3 = 3 contacts 4 = 4 contacts 6 = 6 contacts Contact material 0 = AgNi +Au (7S.23) only 0 = AgSnO2 & AgNi + Au (7S.43/63) only 4 = AgSnO2 (7S.14/34) only 5 = AgNi +Au (7S.12/32) only 5 = AgSnO2 + Au (7S.16/36) only Supply version 8 = AC (50 /60 Hz) 9 = DC Supply voltage See page 10 Codes, Preferred selections for best availability are shown in bold. 7S.12.9.012.5110 7S.14.9.012.4220 7S.16.9.012.5420 7S.12.9.024.5110 7S.14.9.012.4310 7S.16.9.024.5420 7S.12.8.120.5110 7S.14.9.024.4220 7S.16.9.024.5510 7S.12.8.230.5110 7S.14.9.024.4310 7S.16.9.110.5420 7S.14.9.110.4220 7S.16.8.120.5420 7S.32.9.012.5110 7S.14.9.110.4310 7S.16.8.230.5420 7S.32.9.024.5110 7S.14.8.120.4220 7S.32.8.120.5110 7S.14.8.120.4310 7S.36.9.012.5420 7S.32.8.230.5110 7S.14.8.230.4220 7S.36.9.024.5420 7S.14.8.230.4310 7S.36.9.024.5510 7S.43.9.012.0211 7S.36.9.110.5420 7S.43.9.024.0211 7S.34.9.012.4220 7S.36.8.120.5420 7S.43.9.048.0211 7S.34.9.012.4310 7S.36.8.230.5420 7S.43.9.110.0211 7S.34.9.024.4220 7S.34.9.024.4310 7S.23.9.012.0210 7S.63.9.012.0211 7S.34.9.110.4220 7S.23.9.024.0210 7S.63.9.024.0211 7S.34.9.110.4310 7S.23.9.048.0210 7S.63.9.048.0211 7S.34.8.120.4220 7S.23.9.110.0210 7S.63.9.110.0211 7S.34.8.120.4310 7S.34.8.230.4220 VII-2022, www.findernet.com 7S.34.8.230.4310 6 7S 7S SERIES Modular relays with forcibly guided contacts 6 - 10 A SERIES Technical data Insulation according to EN 61810-1 Nominal voltage of supply system V AC 230/400 Rated insulation voltage V AC 250 Pollution degree 2 Insulation between coil and contact set Type of Insulation Reinforced Overvoltage category III Rated impulse voltage kV (1.2/50 µs) 6 Dielectric strength V AC 4000 C Insulation between adjacent contacts Type of Insulation Basic Overvoltage category III Rated impulse voltage kV (1.2/50 µs) 4 Dielectric strength V AC 2500 Insulation between open contacts Type of disconnection Micro-disconnection Dielectric strength V AC/kV (1.2/50 µs) 1500/2.5 Insulation between coil terminals Rated impulse voltage (surge) differential mode (according to EN 61000-4-5) kV (1.2/50 µs) 1.5 Terminals Screw Terminal Min. wire size solid cable Screwless Terminal stranded cable solid cable 0.5 0.5 0.5 AWG 21 21 21 21 Screw Terminal Max. wire size solid cable Wire strip length stranded cable mm2 0.5 Screwless Terminal stranded cable solid cable stranded cable mm2 1 x 6 / 2 x 2.5 1 x 4 / 2 x 2.5 1 x 1.5 1 x 1.5 AWG 1 x 10 / 2 x 14 1 x 12 / 2 x 14 1 x 14 1 x 16 mm 9 Other data 7S.12/32 Bounce time: NO/NC ms 2/8 7S.14/34 7S.16/36 7S.23 7S.43/63 2/10 2/10 2/15 1/8 Vibration resistance (10…200)Hz: NO/NC g 10/5 20/6 20/6 10/2 10/2 Shock resistance: NO/NC g 20/6 20/5 20/5 20/6 20/5 without contact current W 0.8 0.8 0.8 0.8 1.7 with rated current W 1.4 2.3 2.8 1.4 3.8 VII-2022, www.findernet.com Power lost to the environment 7 7S 7S SERIES Modular relays with forcibly guided contacts 6 - 10 A SERIES Contact specifications Contact diagrams 7S.12/7S.32 7S.14....4310 7S.14/34....4220 7S.16/36....5420 12 11 7S.16/36....5510 34 33 11 12 43 C 54 33 34 7S.23 7S.43/7S.63 23 23 24 24 11 33 23 12 12 34 24 24 47 47 48 48 33 23 11 47 48 47 48 F 7S12 - Electrical life (AC) v contact current - 7S.12 H 7S12* - Maximum DC breaking capacity - 7S.12 Corrente DC (A) Resistive load Cycles Resistive load - cosφ = 1 Inductive load - AC15 Inductive load - DC13 Tensione DC (V) F 7S14 - Electrical life (AC) v contact current - 7S.14/34 H 7S14* - Maximum DC breaking capacity - 7S.14/34 2 4 6 8 Tensione DC (V) * When switching a load having voltage and current values under the curve, an electrical life of ≥ 100 · 103 can be expected. 8 VII-2022, www.findernet.com Cycles Corrente DC (A) Resistive load - cosφ = 1 Inductive load - AC15 7S 7S SERIES Modular relays with forcibly guided contacts 6 - 10 A SERIES Contact specifications H 7S16* - Maximum DC breaking capacity - 7S.16/36 DC breaking current (A) Cycles F 7S16 - Electrical life (AC) v contact current - 7S.16/36 Resistive load - cosφ = 1 Inductive load - AC15 2 4 6 8 DC voltage (V) H 7S23* - Maximum DC breaking capacity - 7S.23 DC breaking current (A) Cycles F 7S23 - Electrical life (AC) v contact current - 7S.23 C Resistive load - cosφ = 1 Inductive load - AC15 Resistive load Inductive load - DC13 DC voltage (V) H 7S43* - Maximum DC breaking capacity - 7S.43/63 DC breaking current (A) F 7S43 - Electrical life (AC) v contact current - 7S.43/63 Cycles Resistive load - cosφ = 1 Inductive load - AC15 2 4 6 8 Resistive load Inductive load - DC13 DC voltage (V) VII-2022, www.findernet.com * When switching a load having voltage and current values under the curve, an electrical life of ≥ 100 · 103 can be expected. 9 7S 7S SERIES Modular relays with forcibly guided contacts 6 - 10 A SERIES Coil specifications DC coil data - type 7S.12/32 Nominal Coil Operating range voltage code UN V 12 24 Umax V 14.4 30 DC coil data - type 7S.14/34 / 7S.16/36 Operating range Nominal Coil voltage code UN V 12 24 110 9.012 9.024 9.110 Umin V 9.6 16.8 77 Umax V 14.4 30 138 Rated power at UN Rated input current Rated power at UN at UN IN mA 64.7 42.2 11.6 W 0.7 0.9 W 0.8 1 1.4 Coil code Operating range Rated input current at UN UN Umin V UN V 110…125 230…240 8.120 8.230 Umin V 93 195 Umax V 138 264 AC coil data - type 7S.14/34 / 7S.16/36 Nominal Coil Operating range voltage code UN V 110…125 230…240 8.120 8.230 Umin V 93 195 Umax V 138 264 Rated input current at UN IN mA 9.8 11.8 Rated input current at UN IN mA 10.2 11.8 Rated power at UN VA/W 1.2/1.1 2.8/1.2 Rated power at UN VA/W 1.3/1.1 2.9/1.2 DC coil data - type 7S.43/63 DC coil data - type 7S.23 Nominal voltage AC coil data - type 7S.12/32 Nominal Coil Operating range voltage code Umax Rated power at UN IN Nominal voltage Coil code Operating range Rated input current at UN UN Umin Umax V V mA W V 12 9.012 9.6 14.4 47.1 0.6 12 24 9.024 16.8 30 26.6 0.6 24 9.024 20.4 48 9.048 33.6 60 16.2 0.8 48 9.048 40.8 110 9.110 77 138 8.8 1 110 9.110 93.5 121 9.012 Rated power at UN IN V V mA W 10.2 13.2 105 1.3 26.4 60 1.45 52.8 36 1.6 20 1.7 R 7S - DC coil operating range v ambient temperature 7S.12/32 / 7S.23 / 7S.14/34 / 7S.16/36 R 7S - AC coil operating range v ambient temperature 7S.12/32 / 7S.14/34 / 7S.16/36 1 - Max. permitted coil voltage. 2 - Min. pick-up voltage with coil at ambient temperature. - - - - - 24 and 110 V DC coils only (extended range) excluding 7S.23 1 - Max. permitted coil voltage. 2 - Min. pick-up voltage with coil at ambient temperature. R 7S - DC coil operating range v ambient temperature - 7S.43/63 1 - Max. permitted coil voltage. 2 - Min. pick-up voltage with coil at ambient temperature. 10 VII-2022, www.findernet.com C 9.012 9.024 Umin V 9.6 16.8 Rated input current at UN IN mA 55 38.2 7S 7S SERIES Modular relays with forcibly guided contacts 6 - 10 A SERIES Example wiring diagrams Type 7S.x2 Type 7S.x4....4220 Safety PLC feedback output Safety PLC feedback output C feedback Type 7S.43 Safety PLC L feedback output K1 K2 K3 K4 23 47 48 K2 K3 K1 K4 feedback 3 VII-2022, www.findernet.com 4 11 7S SERIES 7S SERIES Modular relays with forcibly guided contacts 6 - 10 A Outline drawings Types 7S.12/14/16/43 Screwless terminal Type 7S.23 Screw terminal C Type 7S.63 Screw terminal 96 78.8 4.3 30.5 86.2 22.5 59.5 Type 7S.36 Screw terminal Type 7S.34 Screw terminal 33.8 Type 7S.32 Screw terminal Sheet of marker tags, plastic, 48 tags, 6 x 12 mm, for CEMBRE thermal transfer printers 060.48 060.48 12 Please see general technical information VII-2022, www.findernet.com Accessories
7S.14.8.230.4220
物料型号: - 7S.12/32 - 7S.14/34 - 7S.16/36 - 7S.23 - 7S.43/63

器件简介: FINDER品牌的7S系列模块化继电器,具有强制导向触点,适用于6-10A的应用场景,如化工、起重设备、木材加工机械、自动洗车机、扶梯、电梯、过程工业等。

引脚分配: - 2极 (1常开 + 1常闭) - 4极 (2常开 + 2常闭 或 3常开 + 1常闭) - 6极 (4常开 + 2常闭 或 5常开 + 1常闭)

参数特性: - 安全应用:符合EN 61810-3标准的A类强制导向接触继电器 - 根据EN 61508评估为SIL2,适用于EN 62061高达SIL2的功能安全应用 - 适用于机械和工厂工程的功能可靠性 - 适用于铁路应用,材料符合EN 45545的防火和烟雾特性

功能详解: - 提供直流和交流供电版本 - 24和110V直流版本具有扩展的工作范围 - LED指示线圈状态 - 35mm导轨安装

应用信息: 适用于安全应用、功能安全应用、机械和工厂工程的功能可靠性、铁路应用等。

封装信息: - 机械寿命:10^6次 - 电气寿命(额定负载AC1):10^5次 - 操作/释放时间:根据型号不同而有所差异 - 绝缘强度:根据型号和测试条件不同而有所差异 - 环境温度范围:-40°C至+70°C - 保护类别:IP 20
7S.14.8.230.4220 价格&库存

很抱歉,暂时无法提供与“7S.14.8.230.4220”相匹配的价格&库存,您可以联系我们找货

免费人工找货