0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
39.30.7.006.9024

39.30.7.006.9024

  • 厂商:

    FINDER

  • 封装:

  • 描述:

  • 数据手册
  • 价格&库存
39.30.7.006.9024 数据手册
MasterINTERFACE 39 Series - Relay interface modules Common features • • • • • • Space saving 6.2 mm wide Connections for 16-way jumper link Integral coil indication and protection circuit Secure retention and easy ejection by plastic clip Dual screw head (blade+cross) terminals 35 mm rail mounting (EN 60715) MasterBASIC • For general use in any type of system • EMR: 6 to 24 V AC/DC and 230 V AC supply SSR: 6 to 24 V DC and 230 V AC supply • EMR Electromechanical Relays • • SSR Solid State Relays 1 CO 6 A 250 V AC High switching capability • • 39.11 1 solid state output (options 0.1 A 48 V DC, 2 A 24 V DC, 2 A 240 V AC) Silent, high speed switching, long electrical life 39.10 Page 5 Page 4 MasterPLUS • Accepts the output fuse module, for the easy and space efficient protection of output circuits • EMR: 6 to 125 V AC/DC, 125 and 220 V DC, 230 V AC supply SSR: 24 - 125 V AC/DC, 6 to 220 V DC and 230 V AC supply • • 39.31 - 39.31.3 39.30 - 39.30.3 Special 125 and 230 V AC leakage current suppression types (39.31.3 EMR and 39.30.3 SSR) Page 6 MasterINPUT • Jumper link option for the quick and easy distribution of supply voltage to proximity switches and similar input devices • EMR: 6 to 24 V and 125 V AC/DC, 230 V AC supply SSR: 6 - 12 V DC, 24 - 125 V AC/DC, 230 V AC supply • 39.41 Page 7 39.40 Page 8 MasterOUTPUT • Jumper link option for the quick and easy distribution of supply voltage to output side and its connection to electromagnetic valves and similar output devices • EMR:6 to 24 V and 125 V AC/DC, 230 V AC supply SSR: 6 to 24 V DC, 125 V AC/DC, 230 V AC supply • 39.21 Page 9 39.20 Page 10 MasterTIMER • Timer adjustment via top mounted rotary knob accessible after assembly Control signal terminal DIP-switch for selection of 4 time scales and 8 functions Output with fuse module option • EMR and SSR: 12 to 24 V AC/DC supply • • • 39.81 Page 11 39.80 Page 12 Page 13 Typical Applications MasterBASIC 39.11 - 39.10 MasterPLUS 39.31 - 39.30 - 39.31.3 - 39.30.3 • For general interface use in any type of system and application. • Can be used for input interface applications between auxiliary contacts, sensors etc. and controllers, PLCs’ or motors. Or for output interface between PLC’s controllers and relays, solenoids etc. • This special version provides extra protection for the output circuit thanks to the replaceable fuse module. • For general interface use in any type of system and application. • Can be used for input interface applications between auxiliary contacts, sensors etc. and controllers, PLCs’ or motors. Or for output interface between PLC’s controllers and relays, solenoids etc. Output devices Output devices Fuse module 093.63 PLC - Output PLC - Output PLC - Input PLC - Input Fuse module 093.63 Input devices 2 Input devices Typical Applications MasterINPUT 39.41 - 39.40 MasterOUTPUT 39.21 - 39.20 MasterTIMER 39.81 - 39.80 • These models allow the full termination of • These models allow the full termination of • Slim and Multifunction Timed Interface input device to the interface without the need output device to the interface without the modules. for additional terminals - saving component need for additional terminals - saving cost, time and panel space. component cost, time and panel space. • Quick and easy distribution of supply voltage • Quick and easy distribution of supply voltage through the jumper link on the Bus-Bar (BB) through the jumper link on the Bus-Bar (BB) connection. connection. • Ideal for interface applications between the • Ideal for interface applications between the auxiliary contacts, sensors, limit switches and PLC’s or Controllers and output devices such Controllers or PLC’s. as electomagnetic valves or motors etc.. Output devices Output devices Fuse module 093.63 PLC - Output PLC - Input Input devices PLC - Output PLC - Input Input devices 3 39 Series - Relay interface modules 0.1 - 2 - 6 A MasterBASIC - EMR 39.11 Features 1 Pole interface module, 6.2 mm wide, ideal for PLC and electronic systems • Common connection possible with optional jumper links (terminals A1, A2 and 11) • • • 6 A electromechanical relay 6 to 24 V AC/DC and 230 V AC supply 35 mm rail (EN 60715) mounting 39.11 Screw terminal For outline drawing see page 20 Contact specification 1 CO (SPDT) Contact configuration Rated current/Maximum peak current A Rated voltage/Maximum switching voltage Rated load AC1 V AC VA Rated load AC15 (230 V AC) Single phase motor rating (230 V AC) 250/400 1,500 VA 300 kW 0.185 A 6/0.2/0.12 mW (V/mA) 500 (12/10) Breaking capacity DC1: 30/110/220 V Minimum switching load 6/10 AgNi Standard contact material Supply specification Nominal voltage (UN) V AC/DC V AC (50/60 Hz) Rated power VA (50 Hz)/W 6 - 12 - 24 220...240 See page 16 Operating range (0.8...1.1)UN Holding voltage 0.6 UN 0.1 UN Must drop-out voltage (0.8...1.2)UN Technical data Mechanical life AC/DC cycles 10 · 106 Electrical life at rated load AC1 cycles 60 · 103 Operate/release time ms Insulation between coil and contacts (1.2/50 μs) kV Dielectric strength between open contacts Ambient temperature range Protection category Approvals relay (according to type) 4 V AC °C 5/6 6 (8 mm) 1,000 –40…+70 IP 20 39 Series - Relay interface modules 0.1 - 2 - 6 A MasterBASIC - SSR 39.10 Features 1 Pole interface module, 6.2 mm wide, ideal for PLC and electronic systems • Common connection possible with optional jumper links (terminals A1, A2 and 13+) • • • 0.1 or 2 A solid state relay 6 to 24 V DC and 230 V AC supply 35 mm rail (EN 60715) mounting 39.10 Screw terminal For outline drawing see page 20 39.10.x.xxx.9024 39.10.x.xxx.7048 39.10.x.xxx.8240 Output specification (SSR) 1 NO (SPST-NO) Contact configuration A 2/20 DC 0.1/0.5 DC 2/40 AC Rated voltage/Maximum blocking voltage V 24/33 DC 48/60 DC 240/275 AC Switching voltage range V (1.5…24) DC Rated current/Maximum peak current (10 ms) (1.5…48) DC (12…240) AC Minimum switching current mA 1 Max. “OFF-state” leakage current mA 0.001 0.001 1.5 0.12 1 1.6 V Max. “ON-state” voltage drop 0.05 22 Supply specification Nominal voltage (UN) V AC (50/60 Hz) 220...240 V DC 6 - 12 - 24 Rated power See page 17 VA (50 Hz)/W (0.8…1.1) UN Operating range 0.1 UN Must drop-out voltage Technical data Operate/release time Dielectric strength between input/output Ambient temperature range Protection category ms V AC °C 0.2/0.6 0.04/0.11 12/12 2,500 –20…+55 IP20 Approvals relay (according to type) 5 39 Series - Relay interface modules 0.1 - 2 - 6 A MasterPLUS - EMR 39.31 39.31.3 Features 1 Pole interface modules, 6.2 mm wide, ideal for PLC and electronic systems • • Accepts output fuse module 093.63 (for 5 x 20 mm fuses) for quick and easy load protection, see page 22 Common connection possible with optional jumper links (terminals A1, A2 and 11) • • • 6 A electromechanical relay 6 to 125 V AC/DC, 125 and 220 V DC, 230 V AC supply 35 mm rail (EN 60715) mounting • • 6 A electromechanical relay Leakage current suppression version, 125 and 230 V AC supply 39.31 / 39.31.3 Screw terminal Fuse module 093.63 For outline drawing see page 20 Contact specification Contact configuration 1 CO (SPDT) Rated current/Maximum peak current A Rated voltage/Maximum switching voltage V AC 1 CO (SPDT) 6/10 6/10 250/400 250/400 Rated load AC1 VA 1,500 1,500 Rated load AC15 (230 V AC) VA 300 300 Single phase motor rating (230 V AC) kW 0.185 0.185 A 6/0.2/0.12 6/0.2/0.12 mW (V/mA) 500 (12/10) 500 (12/10) AgNi AgNi Breaking capacity DC1: 30/110/220 V Minimum switching load Standard contact material Supply specification Nominal voltage (UN) V AC/DC V AC (50/60 Hz) V DC 6 - 12 - 24 - 60 - 110…125 — 220...240 110…125 - 220…240 110…125 - 220 — See page 16 See page 16 Operating range (0.8…1.1) UN (0.8…1.1) UN Holding voltage 0.6 UN 0.6 UN Must drop-out voltage 0.1 UN 0.3 UN Rated power VA (50 Hz)/W Technical data Mechanical life AC/DC cycles 10 · 106 10 · 106 Electrical life at rated load AC1 cycles 60 · 103 60 · 103 5/6 5/6 6 (8 mm) 6 (8 mm) 1,000 1,000 –40…+70 (+55 for 220 V DC) –40…+70 IP20 IP20 Operate/release time ms Insulation between coil and contacts (1.2/50 μs) kV Dielectric strength between open contacts Ambient temperature range Protection category Approvals relay (according to type) 6 V AC °C 39 Series - Relay interface modules 0.1 - 2 - 6 A MasterPLUS - SSR 39.30 39.30.3 Features 1 Pole interface modules, 6.2 mm wide, ideal for PLC and electronic systems • • Accepts output fuse module 093.63 (for 5 x 20 mm fuses) for quick and easy load protection, see page 22 Common connection possible with optional jumper links (terminals A1, A2 and 13+) • • • 0.1 or 2 A solid state relay 24 - 125 V AC/DC, 6 to 220 V DC and 230 V AC supply 35 mm rail (EN 60715) mounting • • 0.1 or 2 A solid state relay Leakage current suppression version, 125 and 230 V AC supply 39.30 / 39.30.3 Screw terminal Fuse module 093.63 For outline drawing see page 20 Output specification (SSR) 39.30.x.xxx.9024 39.30.x.xxx.7048 39.30.x.xxx.8240 39.30.3.xxx.9024 39.30.3.xxx.7048 39.30.3.xxx.8240 Contact configuration 1 NO (SPST-NO) Rated current/Maximum peak current (10 ms) A 2/20 DC Rated voltage/Maximum blocking voltage V 24/33 DC Switching voltage range V (1.5…24) DC 2/40 AC 2/20 DC 48/60 DC 240/275 AC 24/33 DC (1.5…48)DC (12…240) AC (1.5…24) DC Minimum switching current mA 1 0.05 Max. “OFF-state” leakage current mA 0.001 0.12 Max. “ON-state” voltage drop V 1 NO (SPST-NO) 0.1/0.5 DC 0.1/0.5 DC 2/40 AC 48/60 DC 240/275 AC (1.5…48)DC (12…240) AC 22 1 0.05 22 0.001 1.5 0.001 0.001 1.5 1 1.6 0.12 1 1.6 Supply specification Nominal voltage (UN) V AC/DC V AC (50/60 Hz) V DC Rated power 24 - 110…125 — 220...240 110…125 - 220…240 6 - 12 - 24 - 60 - 110…125 - 220 VA (50 Hz)/W Operating range Must drop-out voltage — See page 17 See page 17 (0.8…1.1) UN (0.8…1.1) UN 0.1 UN 0.3 UN Technical data Operate/release time Dielectric strength between input/output Ambient temperature range Protection category ms V AC °C 0.2/0.6 0.04/0.11 12/12 0.2/0.6 0.04/0.11 2,500 2,500 –20…+55 –20…+55 IP20 IP20 12/12 Approvals relay (according to type) 7 39 Series - Relay interface modules 0.1 - 2 - 6 A MasterINPUT - EMR 39.41 Features 1 Pole interface module, 6.2 mm wide, ideal for PLC and electronic systems • • Jumper link option for the quick and easy distribution of supply voltage to proximity switches and similar input devices (Bus-bar connection BB) Gold plated output contact as standard, for better compatibility with low energy PLC inputs • • • 6 A electromechanical relay 6 - 12 - 24 - 125 V AC/DC and 230 V AC supply 35 mm rail (EN 60715) mounting 39.41 Screw terminal For outline drawing see page 20 1 Contact specification 1 CO (SPDT) Contact configuration A Rated current/Maximum peak current V AC Rated voltage/Maximum switching voltage VA Rated load AC1 Rated load AC15 (230 V AC) Single phase motor rating (230 V AC) 1,500 VA 300 0.185 mW (V/mA) Minimum switching load 250/400 kW A Breaking capacity DC1: 30/110/220 V 6/10 6/0.2/0.12 50 (5/2) AgNi + Au Standard contact material Supply specification V AC/DC Nominal voltage (UN) V AC (50/60 Hz) Rated power VA (50 Hz)/W 6 - 12 - 24 - 110…125 220...240 See page 16 Operating range (0.8…1.1) UN Holding voltage 0.6 UN Must drop-out voltage 0.1 UN Technical data Mechanical life AC/DC cycles 10 · 106 Electrical life at rated load AC1 cycles 60 · 103 Operate/release time Insulation between coil and contacts (1.2/50 μs) Dielectric strength between open contacts Ambient temperature range Protection category Approvals relay (according to type) 8 ms 5/6 kV 6 (8 mm) V AC °C 1,000 –40…+70 IP20 39 Series - Relay interface modules 0.1 - 2 - 6 A MasterINPUT - SSR 39.40 Features 1 Pole interface modules, 6.2 mm wide, ideal for PLC and electronic systems • Jumper link option for the quick and easy distribution of supply voltage to proximity switches and similar input devices (Bus-bar connection BB) • • • 0.1 or 2 A solid state relay 6 - 12 V DC, 24 - 125 V AC/DC and 230 V AC supply 35 mm rail (EN 60715) mounting 39.40 Screw terminal For outline drawing see page 20 Output specification (SSR) 39.40.x.xxx.9024 39.40.x.xxx.7048 39.40.x.xxx.8240 Contact configuration 1 NO (SPST-NO) Rated current/Maximum peak current (10 ms) A 2/20 DC 0.1/0.5 DC 2/40 AC Rated voltage/Maximum blocking voltage V 24/33 DC 48/60 DC 240/275 AC Switching voltage range V (1.5…24) DC (1.5…48) DC (12…240) AC Minimum switching current mA 1 0.05 22 Max. “OFF-state” leakage current mA 0.001 0.001 1.5 0.12 1 1.6 Max. “ON-state” voltage drop V Supply specification Nominal voltage (UN) V AC/DC 24 - 110...125 V AC (50/60 Hz) 220...240 V DC Rated power 6 - 12 VA (50 Hz)/W See page 17 Operating range (0.8…1.1) UN Must drop-out voltage 0.1 UN Technical data Operate/release time Dielectric strength between input/output Ambient temperature range Protection category ms V AC °C 0.2/0.6 0.04/0.11 12/12 2,500 –20…+55 IP20 Approvals relay (according to type) 9 39 Series - Relay interface modules 0.1 - 2 - 6 A MasterOUTPUT - EMR 39.21 Features 1 Pole interface modules, 6.2 mm wide, ideal for PLC and electronic systems • Jumper link option for the quick and easy distribution of supply voltage to output side (Bus-bar connection BB) and its connection to electromagnetic valves and similar output devices • • • 6 A electromechanical relay 6 - 12 - 24 - 125 V AC/DC and 230 V AC supply 35 mm rail (EN 60715) mounting 39.21 Screw terminal For outline drawing see page 20 1 Contact specification 1 NO (SPST-NO) Contact configuration A Rated current/Maximum peak current V AC Rated voltage/Maximum switching voltage VA Rated load AC1 Rated load AC15 (230 V AC) Single phase motor rating (230 V AC) 250/400 1,500 VA 300 kW 0.185 A 6/0.2/0.12 mW (V/mA) 500 (12/10) Breaking capacity DC1: 30/110/220 V Minimum switching load 6/10 AgNi Standard contact material Supply specification V AC/DC Nominal voltage (UN) V AC (50/60 Hz) Rated power VA (50 Hz)/W 6 - 12 - 24 - 110…125 220...240 See page 16 Operating range (0.8…1.1) UN Holding voltage 0.6 UN Must drop-out voltage 0.1 UN Technical data Mechanical life AC/DC cycles 10 · 106 Electrical life at rated load AC1 cycles 60 · 103 Operate/release time Insulation between coil and contacts (1.2/50 μs) Dielectric strength between open contacts Ambient temperature range Protection category Approvals relay (according to type) 10 ms 5/6 kV 6 (8 mm) V AC °C 1,000 –40…+70 IP20 39 Series - Relay interface modules 0.1 - 2 - 6 A MasterOUTPUT - SSR 39.20 Features 1 Pole interface modules, 6.2 mm wide, ideal for PLC and electronic systems • Jumper link option for the quick and easy distribution of supply voltage to output side (Bus-bar connection BB) and its connection to electromagnetic valves and similar output devices • • • 0.1 or 2 A solid state relay 6 to 24 V DC, 125 V AC/DC and 230 V AC supply 35 mm rail (EN 60715) mounting 39.20 Screw terminal For outline drawing see page 20 Output specification (SSR) 39.20.x.xxx.9024 39.20.x.xxx.7048 39.20.x.xxx.8240 Contact configuration 1 NO (SPST-NO) Rated current/Maximum peak current (10 ms) A 2/20 DC 0.1/0.5 DC 2/40 AC Rated voltage/Maximum blocking voltage V 24/33 DC 48/60 DC 240/275 AC Switching voltage range V (1.5…24) DC (1.5…48) DC (12…240) AC Minimum switching current mA 1 0.05 Max. “OFF-state” leakage current mA 0.001 0.001 1.5 0.12 1 1.6 Max. “ON-state” voltage drop V 22 Supply specification Nominal voltage (UN) V AC/DC 110...125 V AC (50/60 Hz) 220...240 V DC 6 - 12 - 24 Rated power VA (50 Hz)/W See page 17 Operating range (0.8…1.1) UN Must drop-out voltage 0.1 UN Technical data Operate/release time Dielectric strength between input/output Ambient temperature range Protection category ms V AC °C 0.2/0.6 0.04/0.11 12/12 2,500 –20…+55 IP20 Approvals relay (according to type) 11 39 Series - Relay interface modules 0.1 - 2 - 6 A MasterTIMER - EMR 39.81 Features Slim timed interface module, 6.2 mm wide, ideal for space-saving timing solutions in panels • • • • • Timer adjustment via top mounted rotary knob, accessible after assembly Control signal terminal DIP-switch for selection of 4 time scales and 8 functions Accepts output fuse module 093.63 (for 5 x 20 mm fuses) for quick and easy load protection, see page 22 Common connection possible with optional jumper links (terminals A1, A2 and 15) 6 A electromechanical relay 12 - 24 V AC/DC supply • 35 mm rail (EN 60715) mounting • • 39.81 Screw terminal Fuse module 093.63 For outline drawing see page 20 Contact specification 1 CO (SPDT) Contact configuration Rated current/Maximum peak current A Rated voltage/Maximum switching voltage Rated load AC1 VA Rated load AC15 (230 V AC) Single phase motor rating (230 V AC) 250/400 1,500 VA 300 kW 0.185 A 6/0.2/0.12 mW (V/mA) 500 (12/10) Breaking capacity DC1: 30/110/220 V Minimum switching load V AC 6/10 AgNi Standard contact material Supply specification Nominal voltage (UN) V AC/DC Rated power AC/DC VA (50 Hz)/W 12 - 24 See page 16 Operating range (0.8…1.1) UN Holding voltage 0.6 UN Must drop-out voltage 0.1 UN Technical data (0.1...3)s, (3...60)s, (1...20)min, (0.3...6)h Specified time range Repeatability % ±1 Recovery time ms ≤ 50 Minimum control impulse ms 50 % 5 Setting accuracy – full range Electrical life at rated load AC1 Ambient temperature range Protection category Approvals relay (according to type) 12 cycles °C 60 · 103 –20...+50 IP20 AI: On-delay DI: Interval GI: Pulse (0.5 s) delayed SW: Symmetrical flasher (starting pulse on) BE: Off-delay with control signal CE: On- and off-delay with control signal DE: Interval with control signal on EE: Interval with control signal off 39 Series - Relay interface modules 0.1 - 2 - 6 A MasterTIMER - SSR 39.80 Features Slim timed interface module, 6.2 mm wide, ideal for space-saving timing solutions in panels • • • • • Timer adjustment via top mounted rotary knob; accessible after assembly Start terminal DIP-switch for selection of 4 time scales and 8 functions Accepts output fuse module 093.63 (for 5 x 20 mm fuses) for quick and easy load protection, see page 22 Common connection possible with optional jumper links (terminals A1, A2 and 15+) 0.1 or 2 A solid state relay 12 - 24 V AC/DC supply • 35 mm rail (EN 60715) mounting • • 39.80 Screw terminal Fuse module 093.63 AI: On-delay DI: Interval GI: Pulse (0.5 s) delayed SW: Symmetrical flasher (starting pulse on) BE: Off-delay with control signal CE: On- and off-delay with control signal DE: Interval with control signal on EE: Interval with control signal off For outline drawing see page 20 Output specification (SSR) 39.80.x.xxx.9024 39.80.x.xxx.7048 39.80.x.xxx.8240 Contact configuration 1 NO (SPST-NO) Rated current/Maximum peak current (10 ms) A 2/20 DC 0.1/0.5 DC 2/40 AC Rated voltage/Maximum blocking voltage V 24/33 DC 48/60 DC 240/275 AC Switching voltage range V (1.5…24) DC (1.5…48) DC (12…240) AC Minimum switching current mA 1 0.05 22 Max. “OFF-state” leakage current mA 0.001 0.001 1.5 0.12 1 1.6 Max. “ON-state” voltage drop V Supply specification Nominal voltage (UN) Rated power V AC/DC VA (50 Hz)/W 12 - 24 See page 17 Operating range (0.8…1.1) UN Holding voltage 0.6 UN Must drop-out voltage 0.1 UN Technical data Specified time range (0.1...3)s, (3...60)s, (1...20)min, (0.3...6)h Repeatability % ±1 Recovery time ms ≤ 50 Minimum control impulse ms 50 Setting accuracy – full range % 5 Ambient temperature range °C –20...+50 Protection category IP20 Approvals relay (according to type) 13 39 Series - Relay interface modules - Ordering information Ordering information Example: MasterPLUS 39 series screw terminal interface module, electromechanical relay output, 1 CO (SPDT), 24 V AC/DC coil. 3 9 . 3 A B C D 1 . 0 . 0 2 4 . 0 0 6 0 Series D: Special Version, EMR 0 = Standard Type 1 = MasterBASIC, screw terminal 3 = MasterPLUS, screw terminal, fuse-protectable output 4 = MasterINPUT, screw terminal 2 = MasterOUTPUT, screw terminal 8 = MasterTIMER multifunction, screw terminal, fuse-protectable output C: Options, EMR 6 = Standard B: Contact circuit, EMR 0 = CO (except 39.21, 1 NO) A: Contact material, EMR 0 = AgNi Standard 4 = AgSnO2 5 = AgNi + Au (5 μm) No. of poles 1 = 1 CO (only EMR, except 39.21, 1 NO) 0 = 1 NO (only SSR) ABCD: Output version, SSR 7048 = 0.1 A - 48 V DC 8240 = 2 A - 230 V AC 9024 = 2 A - 24 V DC Coil version, EMR / Input version, SSR 0 = AC (50/60 Hz)/DC 3 = Leakage current suppression AC (50/60 Hz) 7 = DC sensitive 8 = AC (50/60 Hz) Coil voltage, EMR / Input voltage, SSR See page 16 EMR - Selecting features and options: only combinations in the same row are possible. Preferred selections for best availability are shown in bold. Type 39.11 Coil version 0.006 - 0.012 0.024 - 8.230 A B C D 0-4-5 0 6 0 0-4-5 0 6 0 0-4-5 0 6 0 0-4-5 0 6 0 0 0 6 0 0.006 - 0.012 0.024 - 0.060 39.31 0.125 - 8.230 7.125 - 7.220 3.125 - 3.230 0.006 - 0.012 39.41 0.024 - 0.125 8.230 0.006 - 0.012 39.21 0.024 - 0.125 8.230 39.81 0.012 - 0.024 SSR - Selecting features and options: only combinations in the same row are possible. Preferred selections for best availability are shown in bold. Type 39.10 39.30 Input version 7.006 - 7.012 7.024 - 8.230 7.006 - 7.012 7.024 - 7.060 7.125 - 7.220 0.024 - 0.125 Output version, ABCD 7048 - 8240 - 9024 7048 - 8240 - 9024 8.230 3.125 - 3.230 0.006 - 0.012 39.40 0.024 - 0.125 7048 - 8240 - 9024 8.230 0.006 - 0.012 39.20 0.024 - 0.125 7048 - 8240 - 9024 8.230 39.80 14 0.012 - 0.024 7048 - 8240 - 9024 39 Series - Relay interface modules - Technical data Technical data Insulation according to EN 61810-1 Nominal voltage of supply system Rated insulation voltage Pollution degree Insulation between coil and contact set Type of Insulation Overvoltage category Rated impulse voltage Dielectric strength Insulation between open contacts (EMR) Type of disconnection Dielectric strength V AC 230/400 V AC 250 3 Reinforced III kV (1.2/50) μs 6 V AC 4,000 Micro-disconnection V AC/kV (1.2/50) μs 1,000/1.5 Conducted disturbance immunity Fast transients (burst 5/50 ns, 5 kHz) according to EN 61000-4-4 at supply terminals Voltage pulses (surge 1.2/50 μs) according to EN 61000-4-5 at supply terminals (differential mode) Other data Bounce time (EMR) : NO/NC Vibration resistance (EMR,10..55 Hz): NO/NC without contact current Power lost to the environment with rated current Terminals Wire strip length Screw torque 400 2 UN ≤ 60 V UN = 125 V UN = 230 V kV 4 4 4 kV 0.8 2 4 ms 1/6 g 10/15 W 0.2 (24 V) – 0.4 (230 V) W 0.6 (24 V) – 0.9 (230 V) mm 10 Nm 0.5 Solid and stranded cable mm2 1 x 2.5/2 x 1.5 AWG 1 x 14/2 x 16 mm2 1 x 0.2 AWG 1 x 24 Max. wire size Min. wire size Contact specification (EMR) Resistive load - cosϕ = 1 Inductive load - cosϕ = 0.4 H 39 - Maximum DC1 breaking capacity DC breaking current (A) Cycles F 39 - Electrical life (AC) v contact current DC voltage (V) • When switching a resistive load (DC1) having voltage and current values under the curve, an electrical life of ≥ 60·103 can be expected. • In the case of DC13 loads, the connection of a diode in parallel with the load will permit a similar electrical life as for a DC1 load. Note: the release time for the load will be increased. 15 39 Series - Relay interface modules - Technical data Coil specifications - Electromechnical Relay Coil data sensitive DC, type 39.31 Nominal Voltage Coil code UN V 125 Operating range Must drop-out Rated input Rated power current at UN voltage Umin Umax Ur IN at UN V V V mA W (110...125) 7.125 88 138 12.5 4.6 0.6 220 7.220 176 242 22 3.0 0.6 Coil data AC/DC, type 39.11/21/31/41 Nominal Voltage Coil code UN V 6 0.006 Operating range Must drop-out Rated input Rated power current at UN voltage Umin Umax Ur IN at UN V V V mA VA/W 4.8 6.6 0.6 35 0.2/0.2 12 0.012 9.6 13.2 1.5 15 0.2/0.2 24 0.024 19.2 26.4 2.4 11 0.25/0.25 60(1) 0.060 48 66 6.0 125(2) (110…125) 5.7 0.35/0.35 (1) (2) 0.125 88 138 12.5 5.6 0.7/0.7 60 V AC/DC for type 39.31 only 125 V AC/DC for types 39.21/31/41 only Coil data AC, type 39.11/21/31/41 Nominal Voltage Coil code UN V 230 (230...240) 8.230 Operating range Must drop-out voltage Rated input Rated power current at UN Umin Umax Ur IN at UN V V V mA VA/W 184 264 23 4.3 1/0.4 Coil data leakage current suppression versions, type 39.31.3 Nominal Voltage Coil code UN V 125 (110...125) 230 (230...240) Operating range Must drop-out Rated input Rated power current at UN voltage Umin Umax Ur IN at UN V V V mA VA/W 3.125 88 138 44 8.4 1.1/1 3.230 184 264 72 5.9 1.4/0.5 The 39 Series interface modules (supply version 3) have builtin leakage current suppression to address industry concerns of the contacts not dropping-out when there is residual current in the circuit; at (110...125)V  AC and (230...240)V  AC. This problem can occur, for example, when connecting the interface modules to PLC‚s with triac outputs or when connecting via relatively long cables. Coil data AC/DC timer, type 39.81 Nominal Voltage Coil code UN V 16 Operating range (AC/DC) Umin Umax Must drop-out voltage Rated input current at UN Ur DC AC mA Rated power at UN DC AC V V V mA W VA/W 12 0.012 9.6 13.2 1.2 15 23 0.2 0.3/0.2 24 0.024 19.2 26.4 2.4 11 19 0.25 0.4/0.3 39 Series - Relay interface modules - Technical data Input specifications - Solid State Relay Input data sensitive DC, type 39.10/20/30/40 Nominal Voltage Input code UN V 7.006 6 12 24 60 (1) (2) 125 (2) (110...125) 220 (2) Operating range Must drop-out Rated input current at UN voltage Umin Umax Ur IN V V V mA 4.8 6.6 0.6 7.5 Rated power at UN W 0.2 7.012 9.6 13.2 1.2 20.7 0.25 7.024 19.2 26.4 2.4 10.5 0.25 7.060 48 66 6.0 6.4 0.4 7.125 88 138 12.5 4.6 0.6 7.220 176 242 22 3.0 0.6 (1) (2) 24 V DC for type 39.10/20/30 only 60 V DC, 125 V DC and 220 V DC for type 39.30 only (3) 24 V AC/DC for type 39.30/40 only Input data AC/DC, type 39.20/30/40 Nominal Voltage Input code UN V 24 (3) 125 (110...125) Operating range Must drop-out Rated input current at UN voltage Rated power Umin Umax Ur IN at UN V V V mA VA/W 0.024 19.2 0.125 88 26.4 138 2.4 17.5 0.4/0.3 12.5 5.5 0.7/0.7 Input data AC, type 39.10/20/30/40 Nominal Voltage Input code UN V 230 (230...240) 8.230 Operating range Must drop-out Rated input current at UN voltage Rated power Umin Umax Ur IN at UN V V V mA VA/W 184 264 23 4.2 1/0.4 Input data leakage current suppression versions, type 39.30.3 Nominal Voltage Input code UN V 125 (110...125) 230 (230...240) Operating range Must drop-out Rated input current at UN voltage Rated power Umin Umax Ur IN at UN V V V mA VA/W 3.125 88 138 44 8.4 1.1/1 3.230 184 264 72 5.9 1.4/0.5 The 39 Series interface modules (supply version 3) have builtin leakage current suppression to address industry concerns of the contacts not dropping-out when there is residual current in the circuit; at (110...125)V  AC and (230...240)V  AC. This problem can occur, for example, when connecting the interface modules to PLC‚s with triac outputs or when connecting via relatively long cables. Input data AC/DC timer, type 39.80 Nominal Voltage Input code UN V Operating range (AC/DC) Umin Umax Must drop-out voltage Rated input current at UN Ur DC AC mA Rated power at UN DC AC V V mA W VA/W 12 0.012 9.6 13.2 1.2 15 23 0.2 0.3/0.2 24 0.024 19.2 26.4 2.4 11 19 0.25 0.4/0.3 V 17 39 Series - Timed interface modules Timer specifications EMC specifications Type of test Electrostatic discharge Radio-frequency electromagnetic field Fast transients (burst) (5-50 ns, 5 and 100 kHz) Surges (1.2/50 μs) on supply and control signal terminals Radio-frequency common mode (0.15 ÷ 80 MHz) contact discharge air discharge (80 ÷ 1,000 MHz) (1,400 ÷ 2,700 MHz) on Supply terminals on control signal terminals common mode differential mode on Supply terminals on control signal terminals Radiated and conducted emission Other data Bounce time (EMR) : NO/NC Vibration resistance (EMR,10..55 Hz): NO/NC without contact current Power lost to the environment with rated current Terminals Wire strip length Screw torque Reference standard EN 61000-4-2 EN 61000-4-2 EN 61000-4-3 EN 61000-4-3 EN 61000-4-4 EN 61000-4-4 EN 61000-4-5 EN 61000-4-5 EN 61000-4-6 EN 61000-4-6 EN 55022 4 kV 8 kV 10 V/m 10 V/m 4 kV 4 kV 2 kV 0.8 kV 10 V 3V class B ms 1/6 g 10/15 W 0.3 W 0.8 mm 10 Nm 0.5 Solid and stranded cable mm2 1 x 2.5/2 x 1.5 AWG 1 x 14/2 x 16 mm2 1 x 0.2 AWG 1 x 24 Max. wire size Min. wire size Times scales Functions 18 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 (0.1...3)s (3...60)s (1...20)min (0.3...6)h LED Supply voltage NO contact/output OFF Open ON Open ON Open (timing to close in progress) ON Closed 39 Series - Timed interface modules Wiring diagram U = Supply voltage = Output contact 1 2 3 4 5 (AI) On-delay Apply power to timer. Output contacts transfer after preset time has elapsed. Reset occurs when power is removed. 1 2 3 4 5 (DI) Interval Apply power to timer. Output contacts transfer immediately. After the preset time has elapsed, contacts reset. 1 2 3 4 5 (GI) Pulse (0.5s) delayed Apply power to timer. Output contacts transfer after preset time has elapsed. Reset occurs after a fixed time of 0.5s. Without control signal 1 2 3 4 5 With control signal (SW) Symmetrical flasher (starting pulse on) Apply power to timer. Output contacts transfer immediately and cycle between ON and OFF for as long as power is applied. The ratio is 1:1 (time on = time off). 1 2 3 4 5 (BE) Off-delay with control signal Power is permenently applied to the timer. The output contacts transfer immediately on closure of the Signal Switch (S). Opening the Signal Switch initiates the preset delay, after which time the output contacts reset. 1 2 3 4 5 (CE) On- and off-delay with control signal Power is permenently applied to the timer. Closing the Signal Switch (S) initiates the preset delay, after which time the output contacts transfer. Opening the Signal switch initiates the same preset delay, after which time the output contacts reset. * *With DC supply, positive polarity has to be conneted to B1, terminal (according to EN 60204-1). S = Signal switch 1 2 3 4 5 1 2 3 4 5 (DE) Interval with control signal on Power is permenently applied to the timer. On momentary or maintained closure of Signal Switch (S), the output contacts transfer, and remain so for the duration of the preset delay, after which they reset. (EE) Interval with control signal off Power is permenently applied to the timer. On opening of the Signal Switch (S) the output contacts transfer, and remain so for the duration of the preset delay, after which they reset. • Possible to control an external load, such as another relay coil or timer, connected to the control signal terminal B1. ** A voltage other than the supply voltage can be applied to the command Start (B1), example: A1 - A2 = 24 V AC B1 - A2 = 12 V DC 19 39 Series - Relay interface modules 0.1 - 2 - 6 A Outline drawings 39.20 39.21 Screw terminal I REG ERED U MM CO D E S I NI TY E S I 39.40 39.41 Screw terminal E S I 39.80 39.81 Screw terminal ERED ITY G UN MM CO D E S I N REG I ST ERED UN MM CO D E S I ITY N ST I ITY REG N MU G M CO D ERED N REG I ST G 39.30 / 39.30.3 39.31 / 39.31.3 Screw terminal 20 ST TY G CO D NI N ERED U MM N REG I ST G 39.10 39.11 Screw terminal 39 Series - Relay interface modules 0.1 - 2 - 6 A Electromechanical Relay (1 Pole 6 A) & Socket Combinations Interface Module Code MasterBASIC 39.11.0.006.0060 39.11.0.012.0060 39.11.0.024.0060 39.11.8.230.0060 MasterPLUS 39.31.0.006.0060 39.31.0.012.0060 39.31.0.024.0060 39.31.0.060.0060 39.31.0.125.0060 39.31.8.230.0060 39.31.7.125.0060 39.31.7.220.0060 39.31.3.125.0060 39.31.3.230.0060 MasterINPUT 39.41.0.006.5060 39.41.0.012.5060 39.41.0.024.5060 39.41.0.125.5060 39.41.8.230.5060 MasterOUTPUT 39.21.0.006.0060 39.21.0.012.0060 39.21.0.024.0060 39.21.0.125.0060 39.21.8.230.0060 MasterTIMER 39.81.0.012.0060 39.81.0.024.0060 Coil voltage Relay Socket 6 V AC/DC 12 V AC/DC 24 V AC/DC (230...240)V AC 34.51.7.005.0010 34.51.7.012.0010 34.51.7.024.0010 34.51.7.060.0010 6 V AC/DC 12 V AC/DC 24 V AC/DC 60 V AC/DC (110...125)V AC/DC (230...240)V AC (110...125)V DC 220 V DC (110...125)V AC (230...240)V AC 34.51.7.005.0010 34.51.7.012.0010 34.51.7.024.0010 34.51.7.060.0010 34.51.7.060.0010 34.51.7.060.0010 34.51.7.060.0010 34.51.7.060.0010 34.51.7.060.0010 34.51.7.060.0010 93.63.7.024 93.63.7.024 93.63.7.024 93.63.7.060 93.63.0.125 93.63.8.230 93.63.7.125 93.63.7.220 93.63.3.125 93.63.3.230 6 V AC/DC 12 V AC/DC 24 V AC/DC (110…125) V AC/DC (230...240)V AC 34.51.7.005.5010 34.51.7.012.5010 34.51.7.024.5010 34.51.7.060.5010 34.51.7.060.5010 93.64.0.024 93.64.0.024 93.64.0.024 93.64.0.125 93.64.8.230 6 V AC/DC 12 V AC/DC 24 V AC/DC (110…125) V AC/DC (230...240)V AC 34.51.7.005.0010 34.51.7.012.0010 34.51.7.024.0010 34.51.7.060.0010 34.51.7.060.0010 93.62.7.024 93.62.7.024 93.62.7.024 93.62.0.125 93.62.8.230 12 V AC/DC 24 V AC/DC 34.51.7.012.0010 34.51.7.024.0010 93.68.0.024 93.68.0.024 93.61.7.024 93.61.7.024 93.61.7.024 93.61.8.230 Solid State Relay (1 Pole 0.1 or 2 A) & Socket Combinations Example: .xxxx .9024 .7048 .8240 Interface Module Code MasterBASIC 39.10.7.006.xxxx 39.10.7.012.xxxx 39.10.7.024.xxxx 39.10.8.230.xxxx MasterPLUS 39.30.7.006.xxxx 39.30.7.012.xxxx 39.30.7.024.xxxx 39.30.7.060.xxxx 39.30.7.125.xxxx 39.30.7.220.xxxx 39.30.0.024.xxxx 39.30.0.125.xxxx 39.30.8.230.xxxx 39.30.3.125.xxxx 39.30.3.230.xxxx MasterINPUT 39.40.7.006.xxxx 39.40.7.012.xxxx 39.40.0.024.xxxx 39.40.0.125.xxxx 39.40.8.230.xxxx MasterOUTPUT 39.20.7.006.xxxx 39.20.7.012.xxxx 39.20.7.024.xxxx 39.20.0.125.xxxx 39.20.8.230.xxxx MasterTIMER 39.80.0.012.xxxx 39.80.0.024.xxxx Input voltage Relay Socket 6 V DC 12 V DC 24 V DC (230...240)V AC 34.81.7.005.xxxx 34.81.7.012.xxxx 34.81.7.024.xxxx 34.81.7.060.xxxx 6 V DC 12 V DC 24 V DC 60 V DC (110...125)V DC 220 V DC 24 V AC/DC (110...125)V AC/DC (230...240)V AC (110...125)V AC (230...240)V AC 34.81.7.005.xxxx 34.81.7.012.xxxx 34.81.7.024.xxxx 34.81.7.060.xxxx 34.81.7.060.xxxx 34.81.7.060.xxxx 34.81.7.024.xxxx 34.81.7.060.xxxx 34.81.7.060.xxxx 34.81.7.060.xxxx 34.81.7.060.xxxx 93.63.7.024 93.63.7.024 93.63.7.024 93.63.7.060 93.63.7.125 93.63.7.220 93.63.0.024 93.63.0.125 93.63.8.230 93.63.3.125 93.63.3.230 6 V DC 12 V DC 24 V AC/DC (110…125) V AC/DC (230...240)V AC 34.81.7.005.xxxx 34.81.7.012.xxxx 34.81.7.024.xxxx 34.81.7.060.xxxx 34.81.7.060.xxxx 93.64.0.024 93.64.0.024 93.64.0.024 93.64.0.125 93.64.8.230 6 V DC 12 V DC 24 V DC (110…125) V AC/DC (230...240)V AC 34.81.7.005.xxxx 34.81.7.012.xxxx 34.81.7.024.xxxx 34.81.7.060.xxxx 34.81.7.060.xxxx 93.62.7.024 93.62.7.024 93.62.7.024 93.62.0.125 93.62.8.230 12 V AC/DC 24 V AC/DC 34.81.7.012.xxxx 34.81.7.024.xxxx 93.68.0.024 93.68.0.024 93.61.7.024 93.61.7.024 93.61.7.024 93.61.8.230 21 ERED ITY 39 Series - Relay interface modules 0.1 - 2 - 6 A G UN MM CO D E S I N REG I ST Accessories Output fuse module for 39.31/30/81/80 types - For 5 x 20 mm fuses up to 6 A, 250 V - Easy visibility of the fuse condition through the window - Quick connection to socket 093.63 093.63 Multi-state fuse module 0. As delivered, the socket comes without a fuse module. However, the absent fuse is internally replaced with an electrical link - which allows the interface relay to be used without a fuse module. In this state, the peg/indicator is visually hidden and the connection is protected by a special cap. 1. With fuse module inserted after removing the cap, the fuse is positioned electrically in series with the common output terminal of the interface module (11 for EMR versions, 13+ for SSR versions, 15 for EMR timer, 15+ for SSR timer). This state is indicated by the peg/indicator. 2. If the fuse module is extracted (for example; because the fuse element has blown) the output circuit will be locked open, as this will generally be the “safe option”. This state is indicated by the peg/indicator. 3. In order to reinstate the output circuit it is necessary to either re-insert the fuse module (complete with functional fuse), or alternatively, return the peg/indicator to position 0 by gently applying pressure in the direction of the arrow. 22 ERED ITY 39 Series - Relay interface modules 0.1 - 2 - 6 A G UN MM CO D E S I N REG I ST Accessories 093.16 16-way jumper link 093.16 (blue) Rated values 36 A - 250 V 093.16.0 (black) 093.16.1 (red) Possibility of multiple connection, side by side 093.16.0 093.16.1 Dual-purpose plastic separator (1.8 mm or 6.2 mm separation) 093.60 1. By breaking off the protruding ribs (by hand), the separator becomes only 1.8 mm thick; useful for the visual separation of different groups of interfaces, or necessary for the protective separation of different voltages of neighbouring interfaces, or for the protection of cut ends of jumper links. 093.60 2. Leaving the ribs in place provides 6.2mm separation. Simply cutting (with scissors) the relevant segment(s) permits the interconnection across the separator of 2 different groups of interface relays, using the standard jumper link. Sheet of marker tags, plastic, 72 tags, 6x12 mm 060.72 060.72 23 39 Series - Relay interface modules 0.1 - 2 - 6 A Accessories MasterADAPTER 093.68.14.1 The MasterADAPTER permits the easy connection of A1/A2 terminals of up to MasterINTERFACE modules to PLC outputs via a 14-Pole ribbon cable, plus simple 2-wire power supply connection. Technical data Rated current (per signal path) Minimum required supply power 093.68.14.1 Nominal voltage (UN) A 1 W 3 V DC 24 Operating range (0.8...1.1) UN Control logic Positive switching (to A1) Power supply status indication Green LED Ambient temperature range °C –40…+70 Terminals for 24 V control logic Type of connector 14 pole, according to IEC 60603-13 Terminals for 24 V power supply Wire strip length mm 9.5 Screw torque Nm 0.5 Max. wire size solid wire stranded wire 1 x 4/2 x 1.5 AWG 1 x 12/2 x 16 mm2 AWG Connected MasterADAPTER Wiring diagram 24 mm2 1 x 2.5/2 x 1.5 1 x 14/2 x 16
39.30.7.006.9024 价格&库存

很抱歉,暂时无法提供与“39.30.7.006.9024”相匹配的价格&库存,您可以联系我们找货

免费人工找货
39.30.7.006.9024
    •  国内价格
    • 1+438.62041

    库存:2