56 SERIES
Miniature power relays 12 A
56
SERIES
56.32/56.34
Plug-in - 12 A Power relay, 2 & 4 pole
• Flange mount option (Faston 187, 4.8 x 0.5 mm termination)
• AC coils & DC coils
• Lockable test button and mechanical flag
indicator
• Cadmium Free contacts (standard version)
• Contact material options
• 96 series sockets
• Coil EMC suppression
• Accessories
• European Patent
56.32-0300
A
• 2 or 4 pole changeover contact
• Plug-in/Faston 187
56.32
• 2 pole normally open contact (≥ 1.5 mm gap)
• Plug-in/Faston 187
56.32-0300
56.34
* For 4 CO (4PDT) only.
For UL ratings see:
“General technical information” page V
56.32
56.34
56.32-0300
4 CO (4PDT)
2NO (DPST-NO) - ≥ 1.5 mm gap
Contact specification
Contact configuration
2 CO (DPDT)
Rated current/Maximum peak current
Rated voltage/
Maximum switching voltage
A
V AC
12/20
12/20
250/400
250/400
VA
3000
3000
Rated load AC15 (230 V AC)VA
700
700
Single phase motor rating (230 V AC)kW
0.55
0.55
Breaking capacity DC1: 30/110/220 VA
12/0.5/0.25
12/1/0.5
Minimum switching load
500 (10/5)
500 (10/5)
AgNi
AgNi
Rated load AC1
mW (V/mA)
Standard contact material
Coil specification
Nominal voltage (UN)
V AC (50/60 Hz)
V DC
Rated power AC/DC
Operating range
VA (50 Hz)/W
6 - 12 - 24 - 48 - 60 - 110 - 120 - 230 - 240 - 400*
6 - 12 - 24 - 48 - 60 - 110 - 125 - 220
1.5/1
2/1.3
AC
DC
(0.8…1.1)UN
(0.8…1.1)UN
—
1.5/—
(0.85…1.1)UN
(0.85…1.1)UN
—
Holding voltage
AC/DC
0.8 UN / 0.6 UN
0.85 UN/—
Must drop-out voltage
AC/DC
0.2 UN / 0.1 UN
0.2 UN/—
Mechanical life AC/DC
cycles
20 · 106/50 · 106
20 · 106/—
Electrical life at rated load AC1
cycles
100 · 10
100 · 103
Technical data
XI-2016, www.findernet.com
Operate/release time
Insulation between coil
and contacts (1.2/50 μs)
Dielectric strength
between open contacts
Ambient temperature range
Environmental protection
3
ms
8/3
10/4
8/4
kV
4
5
4
V AC
°C
1000
2000
–40…+70
–40…+70
RT I
RT I
Approvals (according to type)
1
56
SERIES
56 SERIES
Miniature power relays 12 A
56.42/56.44
Printed circuit mount
12 A Power relay
• 2 & 4 pole
• AC coils & DC coils
• Cadmium Free contacts (standard version)
• Contact material option
• RT III (wash tight) option available
• 2 or 4 pole changeover contact
• PCB mount
56.44
• 2 pole normally open contact (≥ 1.5 mm gap)
• PCB mount
56.42-0300
56.42
* For 4 CO (4PDT) only.
For UL ratings see:
“General technical information” page V
56.42
Copper side view
56.44
Copper side view
56.42-0300
Copper side view
4 CO (4PDT)
2NO (DPST-NO) - ≥ 1.5 mm gap
Contact specification
Contact configuration
2 CO (DPDT)
Rated current/Maximum peak current
Rated voltage/
Maximum switching voltage
A
V AC
12/20
12/20
250/400
250/400
VA
3000
3000
Rated load AC15 (230 V AC)VA
700
700
Single phase motor rating (230 V AC)kW
0.55
0.55
Breaking capacity DC1: 30/110/220 VA
12/0.5/0.25
12/1/0.5
Minimum switching load
500 (10/5)
500 (10/5)
AgNi
AgNi
Rated load AC1
mW (V/mA)
Standard contact material
Coil specification
Nominal voltage (UN)
V AC (50/60 Hz)
V DC
Rated power AC/DC
Operating range
VA (50 Hz)/W
6 - 12 - 24 - 48 - 60 - 110 - 120 - 230 - 240 - 400*
6 - 12 - 24 - 48 - 60 - 110 - 125 - 220
1.5/1
2/1.3
AC
DC
(0.8…1.1)UN
(0.8…1.1)UN
—
1.5/—
(0.85…1.1)UN
(0.85…1.1)UN
—
Holding voltage
AC/DC
0.8 UN / 0.6 UN
0.85 UN/—
Must drop-out voltage
AC/DC
0.2 UN / 0.1 UN
0.2 UN/—
Mechanical life AC/DC
cycles
20 · 106/50 · 106
20 · 106/—
Electrical life at rated load AC1
cycles
100 · 10
100 · 103
Technical data
Operate/release time
Insulation between coil
and contacts (1.2/50 μs)
Dielectric strength
between open contacts
Ambient temperature range
Environmental protection
Approvals (according to type)
2
3
ms
8/3
10/4
8/4
kV
4
5
4
V AC
°C
1000
2000
–40…+70
–40…+70
RT I
RT I
XI-2016, www.findernet.com
A
56.42-0300
56 SERIES
Miniature power relays 12 A
56
SERIES
Ordering information
Example: 56 series plug-in relay, 2 CO (DPDT), 12 V DC coil, lockable test button and mechanical indicator.
5 6 . 3
A
B
C
D
2 . 9 . 0 1 2 . 0
0
4
0
Series
A: Contact material
0 = Standard AgNi
2 = AgCdO
4 = AgSnO2
Type
3 = Plug-in
4 = PCB
B: Contact circuit
0 = CO (nPDT)
3 = NO (nPST), ≥ 1.5 mm
contact gap
No. of poles
2 = 2 pole, 12 A
4 = 4 pole, 12 A
Coil version
8 = AC (50/60 Hz)
9 = DC
Coil voltage
See coil specifications
Selecting features and options: only combinations in the same row are possible.
Preferred selections for best availability are shown in bold.
Type
56.32
56.34
56.42
56.44
Coil version
A
B
C
D
AC
AC
AC
DC
0-2-4
0-2-4
0-2-4
0-2-4
0
0
3
0
0-2-3-4-5
54
0-3-5
0-2-4-6-7-8-9
0
/
0
0
DC
0-2-4
0
74 - 94
/
AC
0-2-4
0
0-2-3-4-5
0-6-8
AC
0-2-4
0
54
/
DC
DC
DC
AC
AC - DC
0-2-4
0-2-4
0-2-4
0-2-4
0-2-4
0
0
0
0-3
0
0-2-4-6-7
74
0
0
0
0-6-8
/
0-1
0-1
0-1
A
D: Special versions
0 = Standard
1 = Wash tight (RT III) for 56.42 and
56.44 only
6 = Rear flange mount (4 pole only)
8 = Rear 35 mm rail mount (4 pole
only)
For other mounting options see page 6
C: Options
0 = None
2 = Mechanical indicator
3* = LED (AC)
4 = Lockable test button+mechanical
indicator
5* = Lockable test button + LED (AC)
54* = Lockable test button + LED (AC) +
mechanical indicator
6* = Double LED (DC non-polarized)
7* = Lockable test button + double
LED (DC non-polarized)
74* = Lockable test button + double
LED (DC non-polarized) +
mechanical indicator
8* = LED + diode (DC, polarity positive
to pin 7) for 56.32 only
9* = Lockable test button + LED +
diode (DC, polarity positive to pin
7) for 56.32 only
94* = Lockable test button + LED +
diode (DC, polarity positive to
pin 7) + mechanical indicator for
56.32 only
*O
ptions not available for 220 V DC and
400 V AC versions.
Special versions for Rail Applications on request
C: Option 6, 7, 74
Double LED
(DC non-polarized)
O
P A
PEAN
N
T E
PEAN
3
XI-2016, www.findernet.com
1
2
T
EUR
C: Option 8, 9, 94
LED + diode (DC, polarity
positive to pin 7) (56.32 only)
O
C: Option 3, 5, 54
LED (AC)
EUR
Descriptions: options and special versions
Lockable test button and mechanical flag indicator (0040, 0050, 0054, 0070, 0074, 0090,
0094)
The dual-purpose Finder test button can be used in two ways:
Case 1) The plastic pip (located directly above the test button) remains intact. In this case,
when the test button is pushed, the contacts operate. When the test button is released the
contacts return to their former state.
Case 2) The plastic pip is broken-off (using an appropriate cutting tool). In this case, (in
addition to the above function), when the test button is pushed and rotated, the contacts are
latched in the operating state, and remain so until the test button is rotated back to its former
position.
In both cases ensure that the test button actuation is swift and decisive.
3
56 SERIES
Miniature power relays 12 A
56
SERIES
Technical data
Insulation according to EN 61810-1
Nominal voltage of supply system
V AC
Rated insulation voltage
V AC
Pollution degree
Insulation between coil and contact set
Type of Insulation
Overvoltage category
Rated impulse voltage
kV (1.2/50 μs)
Dielectric strength
V AC
Insulation between adjacent contacts
Type of insulation
Overvoltage category
Rated impulse voltage
kV (1.2/50 μs)
Dielectric strength
V AC
Insulation between open contacts
Type of disconnection
Overvoltage category
Rated impulse voltage
kV (1.2/50 μs)
Dielectric strength
V AC/kV (1.2/50 μs)
Conducted disturbance immunity
Burst (5…50)ns, 5 kHz, on A1 - A2
Surge (1.2/50 μs) on A1 - A2 (differential mode)
Other data
Bounce time: NO/NC
ms
Vibration resistance (5…55)Hz: NO/NC
g
Shock resistance
g
Power lost to the environment
without contact current
W
with rated current
W
Recommended distance between relays mounted on PCB
mm
2 CO - 4 CO
230/400
250
3
400
2
2 NO
230/400
250
3
400
2
Basic
III
4
2500
Basic
III
4
2500
Basic
III
4
2500
Basic
III
4
2500
Micro-disconnection
—
—
1000/1.5
Full-disconnection*
II
2.5
2000/3
EN 61000-4-4
EN 61000-4-5
level 4 (4 kV)
level 4 (4 kV)
1/4 (changeover)
17/14
20/14
1 (56.32, 56.42)
3.8 (56.32, 56.42)
≥ 5
3/— (normally open)
1.3 (56.34, 56.44)
6.9 (56.34, 56.44)
Contact specification
F 56 - Electrical life (AC) v contact current
2 - 4 pole relays
Cycles
Resistive load - cosφ = 1
Inductive load - cosφ = 0.4
H 56 - Maximum DC1 breaking capacity
Changeover version
H 56 - M
aximum DC1 breaking capacity
Normally open version
contacts in series
DC voltage (V)
DC voltage (V)
• When switching a resistive load (DC1) having voltage and current values under the curve, an electrical life of ≥ 100 · 103 can be expected.
• In the case of DC13 loads, the connection of a diode in parallel with the load will permit a similar electrical life as for a DC1 load.
Note: the release time of the load will be increased.
4
XI-2016, www.findernet.com
DC breaking current (A)
contacts in series
DC breaking current (A)
A
* Only in applications where over voltage category II is permitted. In applications of over voltage category III: Micro-disconnection.
56 SERIES
Miniature power relays 12 A
56
SERIES
Coil specifications
DC coil data, 2 pole relay
Nominal
voltage
UN
V
6
12
24
48
60
110
125
220
Coil code
9.006
9.012
9.024
9.048
9.060
9.110
9.125
9.220
AC coil data, 2 pole relay
Operating range
Umin
V
4.8
9.6
19.2
38.4
48
88
100
176
Umax
V
6.6
13.2
26.4
52.8
66
121
138
242
Resistance
R
Ω
40
140
600
2400
4000
12500
17300
54000
Rated coil
consumption
I at UN
mA
150
86
40
20
15
8.8
7.2
4
Nominal
voltage
UN
V
6
12
24
48
60
110
120
230
240
Coil code
8.006
8.012
8.024
8.048
8.060
8.110
8.120
8.230
8.240
Operating range
Umin*
V
4.8
9.6
19.2
38.4
48
88
96
184
192
Resistance
Umax
V
6.6
13.2
26.4
52.8
66
121
132
253
264
R
Ω
12
50
190
770
1200
3940
4700
17000
19100
A
Rated coil
consumption
I at UN (50 Hz)
mA
200
97
53
25
21
12.5
12
6
5.3
* Umin = 0.85 UN for normally open version.
DC coil data, 4 pole relay
Nominal
voltage
UN
V
6
12
24
48
60
110
125
220
Coil code
9.006
9.012
9.024
9.048
9.060
9.110
9.125
9.220
AC coil data, 4 pole relay
Operating range
Umin
V
5.1
10.2
20.4
40.8
51
93.5
107
187
Umax
V
6.6
13.2
26.4
52.8
66
121
138
242
Resistance
R
Ω
32.5
123
490
1800
3000
10400
14200
44000
R 56 - DC coil operating range v ambient temperature
2 pole relay
Rated coil
consumption
I at UN
mA
185
97
49
27
20
10.5
8.8
5
Nominal
voltage
UN
V
6
12
24
48
60
110
120
230
240
400
Coil code
8.006
8.012
8.024
8.048
8.060
8.110
8.120
8.230
8.240
8.400
Operating range
Umin
V
4.8
9.6
19.2
38.4
48
88
96
184
192
320
Resistance
Umax
V
6.6
13.2
26.4
52.8
66
121
132
253
264
440
R
Ω
5.7
22
81
380
600
1900
2560
7700
10000
26000
Rated coil
consumption
I at UN (50 Hz)
mA
300
150
90
37
30
16.5
13.4
9
7.5
4.9
R 56 - AC coil operating range v ambient temperature
2 pole relay
1
1
normally open version
2
changeover version
R 56 - DC coil operating range v ambient temperature
4 pole relay
2
2
R 56 - A
C coil operating range v ambient temperature
4 pole relay
1
1
XI-2016, www.findernet.com
2
changeover version
1 - Max. permitted coil voltage.
2 - Min. pick-up voltage with coil at ambient temperature.
2
1 - Max. permitted coil voltage.
2 - Min. pick-up voltage with coil at ambient temperature.
5
56
SERIES
56 SERIES
Miniature power relays 12 A
Accessories
Top flange mount adaptor for 56.32
056.25
A
056.25 with relay
056.25
056.25 with relay
Rear flange mount adaptor for 56.32
056.26
056.26
056.26 with relay
056.26
056.26 with relay
Top 35 mm rail (EN 60715) adaptor for 56.32
056.27
056.27
056.27 with relay
056.27
056.27 with relay
Top flange mount adaptor for 56.34
056.45
056.45
056.45 with relay
056.45
056.45 with relay
Top 35 mm rail (EN 60715) adaptor for 56.34
056.47
056.47
056.47 with relay
056.47
056.47 with relay
Sheet of marker tags for relay type 56.34, plastic, 48 tags, 6 x 12 mm, for
CEMBRE’s thermal transfer printers
060.48
6
060.48
XI-2016, www.findernet.com
056.25
96 SERIES
Sockets and accessories for 56 series relays
56
SERIES
Screw terminal (Box clamp) socket
panel or 35 mm rail mount (EN 60715)
For relay type
96.02
Blue
56.32
96.02.0
Black
96.04
Blue
56.34
96.04.0
Black
A
Accessories
Metal retaining clip
(supplied with socket - packaging code SMA)
Plastic retaining and release clip
(supplied with socket - packaging code SPA)
6-way jumper link
Identification tag
Modules (see table below)
Timer modules (see table below)
Sheet of marker tags for retaining and release clip
094.91.3, plastic, 48 tags, 6 x 12 mm, for CEMBRE's
thermal transfer printers
Technical data
Rated values
Dielectric strength
Protection category
Ambient temperature
96.02
Approvals
(according to type):
96.04
Approvals
(according to type):
Screw torque
094.71
094.91.3
094.06
095.00.4
99.02
86.30
096.71
094.91.30
094.06.0
—
—
090.00.2
—
—
86.00, 86.30
060.48
—
10 A - 250 V
2 kV AC
IP 20
°C –40…+70 (see diagram L96)
Nm 0.8
Wire strip length
Max. wire size for 94.02/04 sockets
094.91.3
mm 8
solid wire
mm2 1 x 6 / 2 x 2.5
AWG 1 x 10 / 2 x 14
stranded wire
1 x 4 / 2 x 2.5
1 x 12 / 2 x 14
Rated current (A)
L 96 - Rated current vs ambient temperature
96.02
P A
N
T E
O
O
T
EUR
EUR
96.02
PEAN
96.04
6-way jumper link for 96.02 socket
Rated values
094.06 (blue)
10 A - 250 V
86 series timer modules
Multi-voltage: (12…240)V AC/DC;
Multi-functions: AI, DI, SW, BE, CE, DE, EE, FE; (0.05 s…100 h)
(12…24)V AC/DC; Bi-function: AI, DI; (0.05 s…100 h)
(110…125)V AC; Bi-function: AI, DI; (0.05 s…100 h)
(230…240)V AC; Bi-function: AI, DI; (0.05 s…100 h)
86.00.0.240.0000
86.30.0.024.0000
86.30.8.120.0000
86.30.8.240.0000
96.04
094.06.0 (black)
PEAN
094.06
86.00
Approvals (according to type):
XI-2016, www.findernet.com
86.30
99.02
Approvals
(according to type):
DC Modules with
non-standard polarity
(+A2) on request.
99.02 coil indication and EMC suppression modules for 96.02 and 96.04 sockets
Diode (+A1, standard polarity)
(6…220)V DC 99.02.3.000.00
LED(6…24)V DC/AC 99.02.0.024.59
LED(28…60)V DC/AC 99.02.0.060.59
LED(110…240)V DC/AC 99.02.0.230.59
LED + Diode (+A1, standard polarity)
(6…24)V DC 99.02.9.024.99
LED + Diode (+A1, standard polarity)
(28…60)V DC 99.02.9.060.99
LED + Diode (+A1, standard polarity)
(110…220)V DC 99.02.9.220.99
LED + Varistor
(6…24)V DC/AC 99.02.0.024.98
LED + Varistor
(28…60)V DC/AC 99.02.0.060.98
LED + Varistor
(110…240)V DC/AC 99.02.0.230.98
RC circuit
(6…24)V DC/AC 99.02.0.024.09
RC circuit
(28…60)V DC/AC 99.02.0.060.09
RC circuit
(110…240)V DC/AC 99.02.0.230.09
Residual current by-pass
(110…240)V AC 99.02.8.230.07
7
56
SERIES
96 SERIES
Sockets and accessories for 56 series relays
Screw terminal (Plate clamp) socket
panel or 35 mm rail (EN 60715) mount
For relay type
A
96.72
Blue
56.32
96.72.0
Black
96.74
Blue
56.34
96.74.0
Black
Accessories
96.72
Approvals
(according to type):
Metal retaining clip
(supplied with socket - packaging code SMA)
Modules (see table below)
Technical data
Rated values
Dielectric strength
Protection category
Ambient temperature
Screw torque
Wire strip length
Max. wire size for 96.72 and 96.74 sockets
094.71
99.01
096.71
12 A - 250 V
2 kV AC
IP 20
°C –40…+70
Nm 0.8
mm 10
solid wire
mm2 1 x 4 / 2 x 4
stranded wire
1 x 4 / 2 x 2.5
AWG 1 x 12 / 2 x 12
1 x 12 / 2 x 14
96.74
Approvals
(according to type):
96.72
99.01
Approvals
(according to type):
99.01 coil indication and EMC suppression modules for types 96.72 and 96.74 sockets
Blue*
Diode (+A1, standard polarity)
(6…220)V DC 99.01.3.000.00
Diode (+A2, non-standard polarity)
(6…220)V DC 99.01.2.000.00
LED
(6…24)V DC/AC 99.01.0.024.59
LED
(28…60)V DC/AC 99.01.0.060.59
LED
(110…240)V DC/AC 99.01.0.230.59
LED + Diode (+A1, standard polarity)
(6…24)V DC 99.01.9.024.99
LED + Diode (+A1, standard polarity)
(28…60)V DC 99.01.9.060.99
LED + Diode (+A1, standard polarity)
(110…220)V DC 99.01.9.220.99
LED + Diode (+A2, non-standard polarity)
(6…24)V DC 99.01.9.024.79
LED + Diode (+A2, non-standard polarity)
(28…60)V DC 99.01.9.060.79
LED + Diode (+A2, non-standard polarity)
LED + Varistor
LED + Varistor
LED + Varistor
RC circuit
RC circuit
RC circuit
Residual current by-pass
(110…220)V DC 99.01.9.220.79
(6…24)V DC/AC
(28…60)V DC/AC
(110…240)V DC/AC
(6…24)V DC/AC
(28…60)V DC/AC
(110…240)V DC/AC
(110…240)V AC
99.01.0.024.98
99.01.0.060.98
99.01.0.230.98
99.01.0.024.09
99.01.0.060.09
99.01.0.230.09
99.01.8.230.07
XI-2016, www.findernet.com
* Modules in Black
housing are available on
request.
Green LED is standard.
Red LED available on
request.
96.74
8
96 SERIES
Sockets and accessories for 56 series relays
56
SERIES
PCB socket
96.12
Approvals
(according to type):
96.12
(blue)
56.32
For relay type
Accessories
96.12.0
(blue)
96.14
(blue)
56.34
96.14.0
(blue)
A
094.51
Technical data
Rated values
Dielectric strength
Protection category
Ambient temperature
15 A - 250 V
2 kV AC
IP 20
°C –40…+70
Copper side view
96.12
Copper side view
96.14
Packaging codes
How to code and identify retaining clip and packaging options for sockets.
Example:
XI-2016, www.findernet.com
9 6 . 7
9 6 . 7
4
4
S M
A
A
Standard packaging
SM
SP
Metal retaining clip
Plastic retaining clip
Without retaining clip
9