0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
58P490240050SMA

58P490240050SMA

  • 厂商:

    FINDER

  • 封装:

  • 描述:

    FINDER - 58P490240050SMA - Power Relay, 4PDT, 24 VDC, 7 A, 58 Series, DIN Rail

  • 数据手册
  • 价格&库存
58P490240050SMA 数据手册
58 SERIES Relay interface modules 7 - 10 A 58 SERIES 58.P3 3 & 4 CO relay interface modules, 31 mm wide with Push-in terminals 58.P4 Ideal interface for PLC and electronic systems Type 58.P3 -- 3 CO 10 A -- Push-in terminals Type 58.P4 -- 4 CO 7 A -- Push-in terminals B • AC coils or DC coils • Supply status indication and EMC coil • 3 CO 10 A • Push-in terminals suppression module as standard • Identification label • Cadmium Free contacts • UL Listing (certain relay/socket combinations) • 35 mm rail (EN 60715) mounting • 4 CO 7 A • Push-in terminals 58.P3 / 58.P4 Push-in terminals For outline drawing see page 7 Example: AC Example: DC 3 CO (3PDT) 4 CO (4PDT) 10/20 7/15 250/400 250/250 Contact specification Contact configuration Rated current/Maximum peak current  Rated voltage/ Maximum switching voltage  A V AC Rated load AC1  VA 2500 1750 Rated load AC15 (230 V AC)  VA 500 350 Single phase motor rating (230 V AC)  kW 0.37 0.125 Breaking capacity DC1: 30/110/220 V  A 10/0.25/0.12 7/0.25/0.12 300 (5/5) 300 (5/5) AgNi AgNi 12 - 24 - 48 - 110 - 120 - 230 12 - 24 - 48 - 110 - 120 - 230 12 - 24 - 48 - 125 12 - 24 - 48 - 125 Minimum switching load  mW (V/mA) Standard contact material Coil specification Nominal voltage (UN)  V AC (50/60 Hz) V DC Rated power AC/DC  Operating range VA (50 Hz)/W AC DC 1.5/1 1.5/1 (0.8…1.1)UN (0.8…1.1)UN (0.8…1.1)UN (0.8…1.1)UN Holding voltage  AC/DC 0.8 UN / 0.5 UN 0.8 UN / 0.5 UN Must drop-out voltage  AC/DC 0.2 UN / 0.1 UN 0.2 UN / 0.1 UN Mechanical life AC/DC  cycles 20 · 106 / 50 · 106 20 · 106 / 50 · 106 Electrical life at rated load AC1  cycles 200 · 103 150 · 103 ms 10/5 (AC) - 10/15 (DC) 11/3 (AC) - 11/15 (DC) kV 3.6 3.6 1000 1000 –40…+70 –40…+70 IP 20 IP 20 Technical data X-2016, www.findernet.com Operate/release time  Insulation between coil and contacts (1.2/50 μs)  Dielectric strength between open contacts  Ambient temperature range  Protection category V AC °C Approvals relay (according to type) 1 58 SERIES 58 SERIES Relay interface modules 7 - 10 A 58.32 2, 3 & 4 CO relay interface modules, 27 mm wide with Screw terminals 58.33 58.34 Ideal interface for PLC and electronic systems Type 58.32 -- 2 CO 10 A -- Screw terminals Type 58.34 -- 4 CO 7 A -- Screw terminals • 2 CO 10 A • Screw terminals • AC coils or DC coils • Supply status indication and EMC coil • 3 CO 10 A • Screw terminals • 4 CO 7 A • Screw terminals suppression module as standard • Identification label • Cadmium Free contacts • UL Listing (certain relay/socket combinations) • 35 mm rail (EN 60715) mounting 58.32 / 58.33 / 58.34 Screw terminals For outline drawing see page 7 Example: AC Example: DC Example: AC 2 CO (DPDT) 3 CO (3PDT) 4 CO (4PDT) 10/20 10/20 7/15 250/400 250/400 250/250 Contact specification Contact configuration Rated current/Maximum peak current  Rated voltage/ Maximum switching voltage  A V AC Rated load AC1  VA 2500 2500 1750 Rated load AC15 (230 V AC)  VA 500 500 350 Single phase motor rating (230 V AC)  kW 0.37 0.37 0.125 Breaking capacity DC1: 30/110/220 V  A 10/0.25/0.12 10/0.25/0.12 7/0.25/0.12 300 (5/5) 300 (5/5) 300 (5/5) AgNi AgNi AgNi 12 - 24 - 48 - 110 - 120 - 230 12 - 24 - 48 - 110 - 120 - 230 12 - 24 - 48 - 110 - 120 - 230 12 - 24 - 48 - 125 12 - 24 - 48 - 125 12 - 24 - 48 - 125 Minimum switching load  mW (V/mA) Standard contact material Coil specification Nominal voltage (UN)  V AC (50/60 Hz) V DC Rated power AC/DC  Operating range VA (50 Hz)/W AC DC 1.5/1 1.5/1 1.5/1 (0.8…1.1)UN (0.8…1.1)UN (0.8…1.1)UN (0.8…1.1)UN (0.8…1.1)UN (0.8…1.1)UN Holding voltage  AC/DC 0.8 UN / 0.5 UN 0.8 UN / 0.5 UN 0.8 UN / 0.5 UN Must drop-out voltage  AC/DC 0.2 UN / 0.1 UN 0.2 UN / 0.1 UN 0.2 UN / 0.1 UN Mechanical life AC/DC  cycles 20 · 106 / 50 · 106 20 · 106 / 50 · 106 20 · 106 / 50 · 106 Electrical life at rated load AC1  cycles 200 · 103 200 · 103 150 · 103 ms 10/5 (AC) - 10/15 (DC) 10/5 (AC) - 10/15 (DC) 11/3 (AC) - 11/15 (DC) kV 3.6 3.6 3.6 1000 1000 1000 –40…+70 –40…+70 –40…+70 IP 20 IP 20 IP 20 Technical data Operate/release time  Insulation between coil and contacts (1.2/50 μs)  Dielectric strength between open contacts  Ambient temperature range  Protection category Approvals relay (according to type) 2 V AC °C X-2016, www.findernet.com B Type 58.33 -- 3 CO 10 A -- Screw terminals 58 SERIES Relay interface modules 6 - 9 - 10 A 58 SERIES 58.32 - x0xx 2, 3 & 4 CO relay interface modules, 27 mm wide with Screw terminals 58.33 - x0xx 58.34 - x0xx ATEX compliant (EX nA nC) Type 58.32 - x0xx -- 2 CO 10 A -- Screw terminals Type 58.33 - x0xx -- 3 CO 9 A -- Screw terminals B Type 58.34 - x0xx -- 4 CO 6 A -- Screw terminals • 2 CO 10 A • Screw terminals • ATEX compliant • AC coils or DC coils • Supply status indication and EMC coil suppression module as standard • 3 CO 9 A • Screw terminals • ATEX compliant • 4 CO 6 A • Screw terminals • ATEX compliant • Mechanical indicator - optional on 2 & 4 CO types • Identification label • Cadmium Free contacts • UL Listed • Complies with: --EN 60079-0:2012 and EN 60079-15:2010 --94/9/CE and 2014/34/UE • 35 mm rail (EN 60715) mounting 58.32 / 58.33 / 58.34 - x0xx Screw terminals For outline drawing see page 7 Example: DC Example: AC Example: DC 2 CO (DPDT) 3 CO (3PDT) 4 CO (4PDT) 10/20 9/20 6/15 250/400 250/400 250/250 Contact specification Contact configuration Rated current/Maximum peak current  Rated voltage/ Maximum switching voltage  A V AC Rated load AC1  VA 2500 2250 1500 Rated load AC15 (230 V AC)  VA 500 500 350 Single phase motor rating (230 V AC)  kW 0.37 0.37 0.125 Breaking capacity DC1: 30/110/220 V  A 10/0.25/0.12 9/0.25/0.12 6/0.25/0.12 300 (5/5) 300 (5/5) 300 (5/5) AgNi AgNi AgNi 12 - 24 - 48 - 110 - 120 - 230 12 - 24 - 48 - 110 - 120 - 230 12 - 24 - 48 - 110 - 120 - 230 12 - 24 - 48 - 125 12 - 24 - 48 - 125 12 - 24 - 48 - 125 Minimum switching load  mW (V/mA) Standard contact material Coil specification Nominal voltage (UN)  V AC (50/60 Hz) V DC Rated power AC/DC  Operating range VA (50 Hz)/W AC DC 1.5/1 1.5/1 1.5/1 (0.8…1.1)UN (0.8…1.1)UN (0.8…1.1)UN (0.8…1.1)UN (0.8…1.1)UN (0.8…1.1)UN Holding voltage  AC/DC 0.8 UN / 0.5 UN 0.8 UN / 0.5 UN 0.8 UN / 0.5 UN Must drop-out voltage  AC/DC 0.2 UN / 0.1 UN 0.2 UN / 0.1 UN 0.2 UN / 0.1 UN Mechanical life AC/DC  cycles 20 · 106 / 50 · 106 20 · 106 / 50 · 106 20 · 106 / 50 · 106 Electrical life at rated load AC1  cycles 150 · 103 150 · 103 150 · 103 ms 11/3 (AC) - 11/15 (DC) 11/3 (AC) - 11/15 (DC) 11/3 (AC) - 11/15 (DC) kV 3.6 3.6 3.6 1000 1000 1000 –40…+70 –40…+70 –40…+70 IP 20 IP 20 IP 20 Technical data X-2016, www.findernet.com Operate/release time  Insulation between coil and contacts (1.2/50 μs)  Dielectric strength between open contacts  Ambient temperature range  Protection category V AC °C Approvals relay (according to type) 3 58 SERIES 58 SERIES Relay interface modules 6 - 7 - 9 - 10 A Ordering information Example: 58 series, 35 mm rail (EN 60715) mounting, Push-in terminals interface module, 4 CO, 24 V DC coil, green LED + diode. 5 8 . P B C D 4 . 9 . 0 2 4 . 0 0 5 0 Series A: Contact material 0 = AgNi Standard 5 = AgNi + Au Type 3 = Screw terminals 35 mm rail (EN 60715) mount P = Push-in terminals 35 mm rail (EN 60715) mount D: Special versions 0 = Standard C: Options 5 = Standard DC: green LED + diode (polarity +A1) 6 = Standard AC: green LED + Varistor B: Contact circuit 0 = CO (nPDT) No. of poles 2 = 2 pole, 10 A 3 = 3 pole, 10 A 4 = 4 pole, 7 A Selecting features and options: only combinations in the same row are possible. Preferred selections for best availability are shown in bold. Coil version 8 = AC (50/60 Hz) 9 = DC Coil voltage See coil specifications Type Coil version A B C D 58.P3/P4/32/33/34 AC 58.P3/P4/32/33/34 DC 0-5 0 6 0 0-5 0 5 0 Ordering information ATEX versions Example: 58 series, 35 mm rail (EN 60715), screw terminal interface module, 4 CO, 120 V AC, green LED, mechanical indicator, ATEX version 5 8 . 3 Series Type 3 = Screw terminals 35 mm rail (EN 60715) mount No. of poles 2 = 2 pole, 10 A 3 = 3 pole, 9 A 4 = 4 pole, 6 A A B C D 4 . 8 . 1 2 0 . 0 0 4 9 A: Contact material 0 = AgNi Standard 2 = AgCdO 5 = AgNi + Au B: Contact circuit 0 = CO (nPDT) D: Special versions 8 = ATEX compliant (Ex nA nC) without mechanical indicator 9 = ATEX compliant (Ex nA nC) with mechanical indicator (2 & 4 CO only) C: Options 4 = Module 99 LED (AC/DC) 5 = Module 99 LED + Diode (DC) Coil version 8 = AC (50/60 Hz) 9 = DC Coil voltage See coil specifications X-2016, www.findernet.com B A 4 58 SERIES Relay interface modules 6 - 7 - 9 - 10 A 58 SERIES Technical data Insulation Insulation according to EN 61810-1 insulation rated voltage  V 400 (2-3 pole) 250 (4 pole) rated impulse withstand voltage kV 3.6 (2-3 pole) 2.5 (4 pole) pollution degree 2 2 overvoltage category III II Insulation between coil and contacts (1.2/50 μs)  B kV 3.6 Dielectric strength between open contacts  V AC 1000 Dielectric strength between adjacent contacts  V AC 2000 (58.32,58.33, 58.P3) 1550 (58.34, 58.P4) Conducted disturbance immunity Burst (5…50)ns, 5 kHz, on A1 - A2 EN 61000-4-4 level 4 (4 kV) Surge (1.2/50 μs) on A1 - A2 (differential mode) EN 61000-4-5 level 4 (4 kV) Other data Bounce time: NO/NC  ms 1/3 Vibration resistance (10…55)Hz: NO/NC  g 6/6 Power lost to the environment without contact current  W 1 with rated current  W 3 (58.32, 58.34, 58.P4) 58.32/33/34 (screw terminals) Wire strip length  Screw torque  Max. wire size 4 (58.P3, 58.33) 58.P3/P4 (Push-in terminals) mm 8 8 Nm 0.5 — stranded cable solid cable stranded cable mm2 1 x 6 / 2 x 2.5 solid cable 1 x 4 / 2 x 2.5 2 x (0.5…1.5) 2 x (0.5…1.5) AWG 1 x 10 / 2 x 14 1 x 12 / 2 x 14 2 x (21…14) 2 x (21…14) Other data ATEX versions Max current @ 70 °C Single piece mount > 1 piece mount Type 58.32 A 10 7 Type 58.33 A 9 6 Type 58.34  A 6 5 Terminal Wire strip length  Screw torque  Wire size mm 8 Nm 0.5 solid cable stranded cable mm2 1 x 2.5 2 x 1.5 AWG 1 x 12 2 x 16 Markings - ATEX versions - ATEX, II 3G Ex nA nC IIC Gc MARKING X-2016, www.findernet.com GAS Specific marking of explosion protection II Component for surface plant (different from mines) 3 Category 3: normal level of protection G Explosive atmosphere due to presence of combustible gas vapour or mist Ex nA Non-sparking equipment Ex nC Sealed device (type of protection for category 3G) IIC Gas group Gc Equipment Protection Level –40 °C ≤ Ta ≤ +70 °C Ambient temperature EPT 15 ATEX 0195 U EPT: laboratory which issues the CE type certificate 15: year of issue of certificate 0195: number of CE type certificate U: ATEX component 5 58 SERIES Relay interface modules 7 - 10 A 58 SERIES Contact specification F 58 - Electrical life (AC) v contact current 2 & 3 pole relays B F 58 - Electrical life (AC) v contact current 4 pole relay Cycles Cycles Resistive load - cosφ = 1 Inductive load - cosφ = 0.4 Resistive load - cosφ = 1 Inductive load - cosφ = 0.4 H 58 - Maximum DC1 breaking capacity • When switching a resistive load (DC1) having voltage and current values 2 & 3 pole current limit under the curve, an electrical life of ≥ 100 · 103 can be expected. • In the case of DC13 loads, the connection of a diode in parallel with the load will permit a similar electrical life as for a DC1 load. Note: the release time for the load will be increased. DC breaking current (A) 4 pole current limit 1 2 3 4 contacts in series DC voltage (V) Coil specifications DC coil data Nominal voltage AC coil data Coil code Operating range Resistance Rated coil absorption Nominal voltage Coil code Operating range Resistance Rated coil absorption UN Umin Umax R I at UN UN Umin Umax R I at UN (50 Hz) V V V Ω mA V V V Ω mA 12 9.012 9.6 13.2 140 86 12 8.012 9.6 13.2 50 97 24 9.024 19.2 26.4 600 40 24 8.024 19.2 26.4 190 53 2400 20 48 8.048 38.4 770 25 110 8.110 88 48 9.048 125 9.125 38.4 52.8 100 138 17300 R 58 - DC coil operating range v ambient temperature 7.2 52.8 121 4000 12.5 120 8.120 96 132 4700 12 230 8.230 184 253 17000 6 R 58 - AC coil operating range v ambient temperature 1 1 1 - Max. permitted coil voltage. 2 - Min. pick-up voltage with coil at ambient temperature. 6 2 1 - Max. permitted coil voltage. 2 - Min. pick-up voltage with coil at ambient temperature. X-2016, www.findernet.com 2 58 SERIES Relay interface modules 7 - 10 A Combinations  ertain relay/socket C combinations 58 SERIES Code Type of socket Type of relay Module Retaining clip 58.P3 94.P3 55.33 99.02 094.91.3 58.P4 94.P4 55.34 99.02 094.91.3 58.32 94.02 55.32 99.02 094.91.3 58.33 94.03 55.33 99.02 094.91.3 58.34 94.04 55.34 99.02 094.91.3 B Outline drawing 58.33 Screw terminals 58.P3 Push-in terminal 58.P4 Push-in terminal 58.34 Screw terminals X-2016, www.findernet.com 58.32 Screw terminals 7 58 SERIES Relay interface modules 7 - 10 A 58 SERIES Accessories 094.52.1 10 A - 250 V 2-way jumper link for type 58.P3 and 58.P4 Rated values 097.52 10 A - 250 V Marker tag holder for type 58.P3, 58.P4, 58.32, 58.33 and 58.34 097.00 6-way jumper link for type 58.32, 58.33, 58.34 094.06 (blue) 094.52.1 097.52 O P A PEAN N T E T EUR EUR 097.00 O PEAN Rated values 094.06.0 (black) 10 A - 250 V O P A 6-way jumper link for type 58.P3 and 58.P4 PEAN N T E T EUR EUR 094.06 O PEAN 094.56 (blue) Rated values 10 A - 250 V 094.56 Sheet of marker tags, plastic, 48 tags, 6 x 12 mm 060.48 060.48 Packaging codes How to code and identify retaining clip and packaging options for sockets. Example: 5 8 . P 4 . 9 . 0 2 4 . 0 0 5 0 S P A A Standard packaging B Blister packaging SP Plastic retaining clip SM Metallic retaining clip (58.32/33/34 - x0xx only) 8 X-2016, www.findernet.com B 2-way jumper link for type 58.P3 and 58.P4 Rated values
58P490240050SMA 价格&库存

很抱歉,暂时无法提供与“58P490240050SMA”相匹配的价格&库存,您可以联系我们找货

免费人工找货