0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
62.83.9.012.0000

62.83.9.012.0000

  • 厂商:

    FINDER

  • 封装:

  • 描述:

  • 数据手册
  • 价格&库存
62.83.9.012.0000 数据手册
62 SЕRIES Power relays 16 A Road / tunnel lighting Industrial furnaces and ovens Burners, boilers and furnaces Control and management of electric power Punches, cleaners, planers and sanders Control panels Circuit breakers and switches Industrial motors FINDER reserves the right to alter characteristics at any time without notice. FINDER assumes no liability for damage to persons or property, caused as a result of the incorrect use or application of its products. 62 SERIES Power relays 16 A 62 SERIES 62.22/62.23 Printed circuit mount 16 A Power relay 62.22-0300/62.23-0300 • 2 & 3 Pole changeover contacts or NO A (≥ 3 mm contact gap) • AC coils & DC coils • Reinforced insulation between coil and contacts according to EN 60335-1, with 6 mm clearance & 8 mm creepage distance • SELV coil-contact separator option • Cadmium free contact material options • 2 & 3 pole changeover contact • PCB mount • 2 & 3 pole normally open contact (≥ 3 mm contact gap) • PCB mount * Distance between contacts ≥ 3 mm (EN 60730-1). ** With the AgSnO2 material the maximum peak current is 120 A - 5 ms (NO contact). For UL ratings see: “General technical information” page V 62.22 Copper side view For outline drawing see page 12 62.23 Copper side view 62.22 - 0300 Copper side view 62.23 - 0300 Copper side view 3 CO (3PDT) 2 NO (DPST-NO), ≥ 3 mm* Contact specification Contact configuration 2 CO (DPDT) Rated current/Maximum peak current Rated voltage/ Maximum switching voltage 3 NO (3PST-NO), ≥ 3 mm* A 16/30** 16/30** V AC 250/400 250/400 Rated load AC1 VA 4000 4000 Rated load AC15 (230 V AC) VA 750 750 Motor rating (230/400 V AC) kW Breaking capacity DC1: 30/110/220 V Minimum switching load A mW (V/mA) Standard contact material 0.8/— 0.8/1.5 0.8/— 0.8/1.5 16/0.6/0.4 16/1.1/0.7 1000 (10/10) 1000 (10/10) AgCdO AgCdO Coil specification Nominal voltage (UN) V AC (50/60 Hz) 6 - 12 - 24 - 48 - 60 - 110 - 120 - 230 - 240 - 400 V DC Rated power AC/DC Operating range VA (50 Hz)/W 6 - 12 - 24 - 48 - 60 - 110 - 125 - 220 2.2/1.3 3/3 AC (0.8…1.1)UN (0.85…1.1)UN DC (0.8…1.1)UN (0.85…1.1)UN Holding voltage AC/DC 0.8 UN / 0.6 UN 0.8 UN / 0.6 UN Must drop-out voltage AC/DC 0.2 UN / 0.1 UN 0.2 UN / 0.1 UN Mechanical life AC/DC cycles 10 · 106/30 · 106 10 · 106/30 · 106 Electrical life at rated load AC1 cycles 100 · 103 100 · 103 ms 11/4 15/3 kV 6 6 1500 3000 –40…+70 –40…+50 RT I RT I Technical data II-2018, www.findernet.com Operate/release time  Insulation between coil and contacts (1.2/50 µs) Dielectric strength between open contacts Ambient temperature range Environmental protection V AC °C Approvals (according to type) 3 62 SERIES 62 SERIES Power relays 16 A 62.32/62.33 Plug-in mount/Faston 187 16 A Power relay • Plug-in (92 series sockets) or Faston 187 (4.8 x 0.5 mm) with optional mounting adaptors • 2 & 3 Pole changeover contacts or NO (≥ 3 mm contact gap) • AC coils & DC coils • UL Listing (certain relay/socket combinations) • LED, mechanical indicator & test button options • Reinforced insulation between coil and contacts according to EN 60335-1, with 6 mm clearance & 8 mm creepage distance • SELV coil-contact separator option • Cadmium free contact material options • Sockets and accessories • European Patent • 2 & 3 pole changeover contact • Plug-in/Faston 187 • 2 & 3 pole normally open contact (≥ 3 mm contact gap) • Plug-in/Faston 187 * Distance between contacts ≥ 3 mm (EN 60730-1). ** With the AgSnO2 material the maximum peak current is 120 A - 5 ms (NO contact). For UL ratings see: “General technical information” page V 62.32 For outline drawing see page 12 62.33 62.32-0300 62.33-0300 Contact specification Contact configuration 2 CO (DPDT) Rated current/Maximum peak current Rated voltage/ Maximum switching voltage 3 CO (3PDT) 2 NO (DPST-NO), ≥ 3 mm* 3 NO (3PST-NO), ≥ 3 mm* A 16/30** 16/30** V AC 250/400 250/400 Rated load AC1 VA 4000 4000 Rated load AC15 (230 V AC) VA 750 750 Motor rating (230/400 V AC) kW Breaking capacity DC1: 30/110/220 V Minimum switching load A mW (V/mA) Standard contact material 0.8/— 0.8/1.5 0.8/— 0.8/1.5 16/0.6/0.4 16/1.1/0.7 1000 (10/10) 1000 (10/10) AgCdO AgCdO Coil specification Nominal voltage (UN) V AC (50/60 Hz) Rated power AC/DC VA (50 Hz)/W 6 - 12 - 24 - 48 - 60 - 110 - 120 - 230 - 240 - 400 V DC Operating range 6 - 12 - 24 - 48 - 60 - 110 - 125 - 220 2.2/1.3 3/3 AC (0.8…1.1)UN (0.85…1.1)UN DC (0.8…1.1)UN (0.85…1.1)UN Holding voltage AC/DC 0.8 UN / 0.6 UN 0.8 UN / 0.6 UN Must drop-out voltage AC/DC 0.2 UN / 0.1 UN 0.2 UN / 0.1 UN Mechanical life AC/DC cycles 10 · 106/30 · 106 10 · 106/30 · 106 Electrical life at rated load AC1 cycles 100 · 103 100 · 103 ms 11/4 15/3 kV 6 6 1500 3000 –40…+70 –40…+50 RT I RT I Technical data Operate/release time  Insulation between coil and contacts (1.2/50 µs) Dielectric strength between open contacts Ambient temperature range Environmental protection Approvals (according to type) 4 V AC °C II-2018, www.findernet.com A 62.32-0300/62.33-0300 62 SERIES Power relays 16 A 62 SERIES 62.82/62.83 Flange mount/Faston 250 16 A Power relay 62.82-0300/62.83-0300 • Faston 250 (6.3 x 0.8 mm) termination Flange or A optional mounting adaptors • 2 & 3 Pole changeover contacts or NO (≥ 3 mm contact gap) • AC coils & DC coils • LED, mechanical indicator & test button options • Reinforced insulation between coil and contacts according to EN 60335-1, with 6 mm clearance & 8 mm creepage distance • 2 & 3 pole changeover contact • Flange mount/Faston 250 • SELV coil-contact separator option • Cadmium free contact material options • European Patent • 2 & 3 pole normally open contact (≥ 3 mm contact gap) • Flange mount/Faston 250 * Distance between contacts ≥ 3 mm (EN 60730-1). ** With the AgSnO2 material the maximum peak current is 120 A - 5 ms (NO contact). For UL ratings see: “General technical information” page V 62.82 For outline drawing see page 12 62.83 62.82-0300 62.83-0300 3 CO (3PDT) 2 NO (DPST-NO), ≥ 3 mm* Contact specification Contact configuration 2 CO (DPDT) Rated current/Maximum peak current Rated voltage/ Maximum switching voltage 3 NO (3PST-NO), ≥ 3 mm* A 16/30** 16/30** V AC 250/400 250/400 Rated load AC1 VA 4000 4000 Rated load AC15 (230 V AC) VA 750 750 Motor rating (230/400 V AC) kW Breaking capacity DC1: 30/110/220 V Minimum switching load A mW (V/mA) Standard contact material 0.8/— 0.8/1.5 0.8/— 0.8/1.5 16/0.6/0.4 16/1.1/0.7 1000 (10/10) 1000 (10/10) AgCdO AgCdO Coil specification Nominal voltage (UN) V AC (50/60 Hz) Rated power AC/DC VA (50 Hz)/W 6 - 12 - 24 - 48 - 60 - 110 - 120 - 230 - 240 - 400 V DC Operating range 6 - 12 - 24 - 48 - 60 - 110 - 125 - 220 2.2/1.3 3/3 AC (0.8…1.1)UN (0.85…1.1)UN DC (0.8…1.1)UN (0.85…1.1)UN Holding voltage AC/DC 0.8 UN / 0.6 UN 0.8 UN / 0.6 UN Must drop-out voltage AC/DC 0.2 UN / 0.1 UN 0.2 UN / 0.1 UN Mechanical life AC/DC cycles 10 · 106/30 · 106 10 · 106/30 · 106 Electrical life at rated load AC1 cycles 100 · 103 100 · 103 11/4 15/3 6 6 1500 3000 –40…+70 –40…+50 RT I RT I Technical data II-2018, www.findernet.com Operate/release time  ms Insulation between coil and contacts (1.2/50 µs)kV Dielectric strength between open contacts V AC Ambient temperature range Environmental protection °C Approvals (according to type) 5 62 SERIES 62 SERIES Power relays 16 A 62.31-4800 Plug-in mount/Faston 187 Magnetic blow power relay • Plug-in (92 series sockets) or Faston 187 (4.8 x 0.5 mm) with optional mounting adaptors • 1 & 2 Pole NO contacts • High DC load (resistive and inductive) switching capability • DC coils • Reinforced insulation between coil and contacts according to EN 60335-1, with 6 mm clearance & 8 mm creepage distance • Cadmium free contact material • Sockets and accessories • 1 pole normally open contact (double break, • 2 pole normally open contact ≥ 4.2 mm contact gap) • Plug-in/Faston 187 • Plug-in/Faston 187 (≥ 2.1 mm contact gap) * Maximum peak current 120 A - 5 ms. 62.31-4800 62.32-4800 1 NO (SPST-NO) double break, ≥ 4.2 mm 2 NO (DPST-NO), ≥ 2.1 mm 16/30* 16/30* For outline drawing see page 12 Contact specification Contact configuration Rated current/Maximum peak current Rated voltage/ Maximum switching voltage Rated load AC1 Breaking capacity DC1: 30/125/220 V A V AC 250/400 250/400 VA 4000 4000 A 16/16/12 16/12/6 Breaking capacity DC inductive (L/R = 40 ms): 30/125/220 VA Minimum switching load mW (V/mA) Standard contact material 16/5/3 10/2/1.2 1000 (10/10) 1000 (10/10) AgSnO2 AgSnO2 Coil specification Nominal voltage (UN)V DC 6 - 12 - 24 - 48 - 60 - 110 - 125 - 220 Rated power DC W 1.3 1.3 Operating range DC (0.85…1.1)UN (0.85…1.1)UN Holding voltage DC 0.6 UN 0.6 UN Must drop-out voltage DC 0.1 UN 0.1 UN Mechanical life DC cycles 10 · 106 10 · 106 Electrical life at rated load DC1 cycles 100 · 103 100 · 103 ms 16/5 16/5 kV 6 6 3000 2000 –40…+70 –40…+70 RT I RT I Technical data Operate/release time  Insulation between coil and contacts (1.2/50 µs) Dielectric strength between open contacts Ambient temperature range Environmental protection Approvals (according to type) 6 V AC °C II-2018, www.findernet.com A 62.32-4800 62 SERIES Power relays 16 A 62 SERIES Ordering information Example: 62 series power relay + Faston 250 (6.3 x 0.8 mm), rear flange mount, 2 NO (DPST-NO), 12 V DC coil. A B C 6 2 . 8 2 . 9 . 0 1 2 . 0 3 A: Contact material 0 = Standard AgCdO 4 = AgSnO2 (standard for versions 4800) Series Type 2 = PCB 3 = Plug-in 8 = Faston 250 (6.3 x 0.8 mm) with rear flange mount B: Contact circuit 0 = CO (nPDT) 3 = NO (nPST), ≥ 3 mm contact gap 5 = CO (nPDT) + additional physical separator between coil and contacts (for SELV applications) 6 = NO (nPST), ≥ 3 mm contact gap + additional physical separator between coil and contacts (for SELV applications) 8 = NO (1 pole double break or 2 pole) with magnetic blow No. of poles 1 = 1 pole (double break) 2 = 2 pole 3 = 3 pole Coil version 8 = AC (50/60 Hz) 9 = DC Coil voltage See coil specifications Selecting features and options: only combinations in the same row are possible. Preferred selections for best availability are shown in bold. Type 62.22/23 62.32/33 62.31/32 62.82/83 Coil version AC-DC AC-DC AC-DC AC AC AC DC DC DC DC AC-DC AC-DC AC AC DC DC 0 A 0-4 0-4 0-4 0-4 0-4 0-4 0-4 0-4 0-4 4 0-4 0-4 0-4 0-4 0-4 0-4 B 0-3-5-6 0-3-5-6 0-5 0 0-3 0 0 0-3 0 8 0-3-5-6 0-5 0 0-3 0 0-3 C 0 0 2-4 2-3-4-5 3 54 4-6-7 6 74 0 0 2-4 2-3-4-5 3 4-6-7 6 D A 0 D: Special versions 0 = Standard 6 = Rear flange mount 9 = Type 62.82/83 without rear flange mount C: Options 0 = None 2 = Mechanical indicator 3 = LED (AC) 4 = Lockable test button + mechanical indicator 5* = Lockable test button + LED (AC) 54* = Lockable test button + LED (AC) + mechanical indicator 6* = LED + diode (DC, polarity positive to pin A/A1) 7* = Lockable test button + LED + diode­ (DC, polarity positive to pin A/A1) 74* = Lockable test button + LED + diode (DC, polarity positive to pin A/A1) + mechanical indicator * Options not available for 220 V DC and 400 V AC versions. D 0 0-6 0-6 0-6 0-6 / 0-6 0-6 / 0 0-9 0 0 0 0 0 Descriptions: Options and Special versions EUR O PEAN E N T Lockable test button and mechanical flag indicator (0040, 0050, 0054, 0070, 0074) P A T The dual-purpose Finder test button can be used in two ways: Case 1) The plastic pip (located directly above the test button) remains intact. In this case, when the test button is pushed, the contacts operate. When the test button is released the contacts return to their former state. PEAN 2 B: Contact circuit 8 Magnetic blow EUR 3 1 II-2018, www.findernet.com B: Contact circuit 5, 6 Additional physical separator between coil and contacts (for SELV applications) C: Option 6, 7, 74 LED + diode (DC, polarity positive to pin A/A1) O C: Option 3, 5, 54 LED (AC) Case 2) The plastic pip is broken-off (using an appropriate cutting tool). In this case, (in addition to the above function), when the test button is pushed and rotated, the contacts are latched in the operating state, and remain so until the test button is rotated back to its former position. In both cases ensure that the test button actuation is swift and decisive. 7 62 SERIES 62 SERIES Power relays 16 A Technical data Insulation according to EN 61810-1 A 2 CO - 3 CO Nominal voltage of supply system V AC 230/400 Rated insulation voltage V AC 400 Pollution degree 2 NO - 3 NO 1 NO* 2 NO* 230/400 230/400 230/400 400 400 400 3 3 3 3 Reinforced Reinforced Reinforced Reinforced Insulation between coil and contact set Type of insulation Overvoltage category Rated impulse voltage III III III III kV (1.2/50 µs) 6 6 6 6 V AC 4000 4000 4000 4000 Basic Basic — Basic Dielectric strength Insulation between adjacent contacts Type of insulation Overvoltage category Rated impulse voltage III III — III kV (1.2/50 µs) 4 4 — 4 2500 — 2500 Dielectric strength V AC 2500 Insulation between open contacts Type of disconnection Micro-disconnection Full-disconnection Full-disconnection Full-disconnection** Overvoltage category — Rated impulse voltage III kV (1.2/50 µs) — Dielectric strength V AC/kV (1.2/50 µs) 1500/2 III II 4 4 2.5 3000/4 3000/4 2000/2.5 3/— (normally open) 3/— (normally open) 3/— (normally open) Conducted disturbance immunity Burst (5...50)ns, 5 kHz, on A1 - A2 according to EN 61000-4-4 level 4 (4 kV) Surge (1.2/50 µs) on A1 - A2 (differential mode) according to EN 61000-4-5 level 4 (4 kV) Other data Bounce time: NO/NC ms 1/5 (changeover) Vibration resistance (10…150)Hz: NO/NC g 20/8 Shock resistance g 15 2 pole (CO) 3 pole (CO) 2 pole (NO) 3 pole (NO) 1 pole (NO)* 2 pole (NO)* Power lost to the environment without contact current with rated current Recommended distance between relays mounted on PCB W 1.3 1.3 3 3 1.3 W 3.3 4.3 5 6 3 mm ≥ 5 1.3 3.3 — II-2018, www.findernet.com * Magnetic blow version ** Only in applications where over voltage category II is permitted. In applications of over voltage category III: Micro-disconnection. 8 62 SERIES Power relays 16 A 62 SERIES Contact specification F 62 - Electrical life (AC) v contact current A Cycles Resistive load - cosϕ = 1 Inductive load - cosϕ = 0.4 H 62 - Maximum DC1 breaking capacity Changeover contacts H 62 - Maximum DC1 breaking capacity Normally open contacts contacts in series DC breaking current (A) DC breeaking current (A) contacts in series Voltage DC (V) Voltage DC (V) • When switching a resistive load (DC1) having voltage and current values under the curve, an electrical life of ≥ 100 · 103 can be expected. • In the case of DC13 loads, the connection of a diode in parallel with the load will permit a similar electrical life as for a DC1 load. Note: the release time of the load will be increased. H 62 - Maximum DC breaking capacity 62.32.9.xxx.4800 H 62 - Maximum DC breaking capacity 62.31.9.xxx.4800 50 DC breeaking current (A) DC breaking current (A) 50 DC1 10 DC13 L/R = 40 ms 1 1 DC13 L/R = 40 ms 0.1 0.1 20 DC1 10 60 100 140 180 Voltage DC (V) 220 260 (V) 20 60 100 140 180 220 Voltage DC (V) 260 (V) • When switching a resistive load (DC1), or a DC13 load with a diode in parallel to the load, having voltage and current values under the DC1 curve, an II-2018, www.findernet.com electrical life of ≥ 100 · 103 can be expected. Note: the release time for the load will be increased. • When switching a DC13 load without a diode in parallel to the load, the DC13 curve applies and an electrical life of ≥ 80 · 103 can be expected. 9 62 SERIES 62 SERIES Power relays 16 A Coil specifications DC version data Coil code 9.006 9.012 9.024 9.048 9.060 9.110 9.125 9.220 AC version data Operating range Umin V 4.8 9.6 19.2 38.4 48 88 100 176 Umax V 6.6 13.2 26.4 52.8 66 121 138 242 Rated coil Resistance consumption R I at UN Ω mA 28 214 110 109 445 54 1770 27 2760 21.7 9420 11.7 12000 10.4 37300 5.8 Coil code 9.006 9.012 9.024 9.048 9.060 9.110 9.125 9.220 Operating range Umin V 5.1 10.2 20.4 40.8 51 93.5 106 187 Umax V 6.6 13.2 26.4 52.8 66 121 138 242 Coil code 8.006 8.012 8.024 8.048 8.060 8.110 8.120 8.230 8.240 8.400 Operating range Umin V 4.8 9.6 19.2 38.4 48 88 96 184 192 320 Umax V 6.6 13.2 26.4 52.8 66 121 132 253 264 440 Rated coil Resistance consumption R I at UN (50Hz) Ω mA 4.6 367 19 183 74 90 290 47 450 37 1600 20 1940 18.6 7250 10.5 8500 9.2 19800 6 AC (NO/nPST-NO) version data - ≥ 3 mm DC (NO/nPST-NO) version data - ≥ 3 mm Nominal voltage UN V 6 12 24 48 60 110 125 220 Nominal voltage UN V 6 12 24 48 60 110 120 230 240 400 Rated coil Resistance consumption R I at UN Ω mA 12 500 48 250 192 125 770 63 1200 50 4200 26 5200 24 17600 12.5 Nominal voltage UN V 6 12 24 48 60 110 120 230 240 400 Coil code 8.006 8.012 8.024 8.048 8.060 8.110 8.120 8.230 8.240 8.400 Operating range Umin V 5.1 10.2 20.4 40.8 51 93.5 106 196 204 340 Umax V 6.6 13.2 26.4 52.8 66 121 137 253 264 440 Rated coil Resistance consumption R I at UN (50Hz) Ω mA 4 540 14 275 62 130 220 70 348 55 1200 30 1350 24 5000 14 6300 12.5 14700 7.8 DC (NO/nPST-NO) magnetic blow version - ≥ 2.1 mm or ≥ 4.2 mm Nominal voltage UN V 6 12 24 48 60 110 125 220 Coil code 9.006 9.012 9.024 9.048 9.060 9.110 9.125 9.220 Operating range Umin V 5.1 10.2 20.4 40.8 51 93.5 106 154* Umax V 6.6 13.2 26.4 52.8 66 121 138 242 Rated coil Resistance consumption R I at UN Ω mA 28 214 110 109 445 54 1770 27 2760 21.7 9420 11.7 12000 10.4 37300 5.8 * Special version with Umin = 70% UN II-2018, www.findernet.com A Nominal voltage UN V 6 12 24 48 60 110 125 220 10 62 SERIES Power relays 16 A 62 SERIES Coil specifications R 62 - DC coil operating range v ambient temperature Changeover contacts R 62 - AC coil operating range v ambient temperature Changeover contacts 1 - Max. permitted coil voltage. 2 - Min. pick-up voltage with coil at ambient temperature. 1 - Max. permitted coil voltage. 2 - Min. pick-up voltage with coil at ambient temperature. R 62 - DC coil operating range v ambient temperature Normally open contacts R 62 - AC coil operating range v ambient temperature Normally open contacts 1 - Max. permitted coil voltage. 2 - Min. pick-up voltage with coil at ambient temperature. 1 - Max. permitted coil voltage. 2 - Min. pick-up voltage with coil at ambient temperature. A R 62 - DC coil operating range v ambient temperature Normally open contacts - magnetic blow version II-2018, www.findernet.com 1 - Max. permitted coil voltage. 2 - Min. pick-up voltage with coil at ambient temperature. 11 62 SERIES 62 SERIES Power relays 16 A Outline drawings Type 62.23 62.23-0300 Type 62.2x Type 62.2x-0300 Type 62.32 62.32-0300 Type 62.33 62.33-0300 Type 62.3x Type 62.3x-0300 Type 62.82 62.82-0300 Type 62.83 62.83-0300 Type 62.8x Type 62.8x-0300 Type 62.31-4800 Type 62.32-4800 II-2018, www.findernet.com A Type 62.22 62.22-0300 12 62 SERIES Power relays 16 A 62 SERIES Accessories Mounting adaptor for types 62.3x and 62.8x.xxxx.xxx9 (M4) 062.10 A 062.10 062.10 with relay 062.10 062.10 with relay Flange mounting adaptor for types 62.3x and 62.8x.xxxx.xxx9 062.60 062.60 062.60 with relay 062.60 062.60 with relay Top flange mount for types 62.3x and 62.8x.xxxx.xxx9 062.05 062.05 062.05 with relay 062.05 Top 35 mm rail (EN 60715) mount for types 62.3x and 62.8x.xxxx.xxx9 062.05 with relay 062.07 062.07 062.07 with relay 062.07 Rear 35 mm rail (EN 60715) mount for types 62.3x and 62.8x.xxxx.xxx9 062.07 with relay 062.08 II-2018, www.findernet.com 062.08 062.08 with relay 062.08 Sheet of marker tags (CEMBRE Thermal transfer printers) for 62 series relays, plastic, 48 tags, 6 x 12 mm 062.08 with relay 060.48 060.48 13 62 SERIES 92 SERIES Sockets and accessories for 62 series relays A Screw terminal (Box clamp) socket panel or 35 mm rail (EN 60715) mount 92.03 Blue 92.03.0 Black For relay type 62.31, 62.32, 62.33 Accessories 92.03 Approvals (according to type): Metal retaining clip (supplied with socket - packaging code SMA) 092.71 Identification tag 092.00.2 Modules (see table below) 99.02 Timer modules (see table below) 86.00, 86.30 Technical data Rated values 16 A - 250 V Dielectric strength 6 kV (1.2/50 µs) between coil and contacts Protection category Ambient temperature Screw torque Wire strip length IP 20 °C –40…+70 (see diagram L92) Nm 0.8 mm 10 Max. wire size for 92.03 socket solid wire stranded wire mm2 1 x 10 / 2 x 4 1 x 6 / 2 x 4 AWG 1 x 8 / 2 x 12 1 x 10 / 2 x 12 Rated current (A) L 92 - Rated current v ambient temperature 86 series timer modules 86.00 Multi-voltage: (12…240)V AC/DC; Multi-functions: AI, DI, SW, BE, CE, DE, EE, FE; (0.05 s…100 h) 86.00.0.240.0000 (12…24)V AC/DC; Bi-function: AI, DI; (0.05 s…100 h) 86.30.0.024.0000 (110...125)V AC; Bi-function: AI, DI; (0.05 s…100 h) 86.30.8.120.0000 (230...240)V AC; Bi-function: AI, DI; (0.05 s…100 h) 86.30.8.240.0000 Approvals (according to type):  86.30 99.02 coil indication and EMC suppression modules for 92.03 socket Diode (+A1, standard polarity) (6...220)V DC 99.02.3.000.00 99.02 Approvals (according to type): DC Modules with non-standard polarity (+A2) on request. LED (28...60)V DC/AC 99.02.0.060.59 LED (110...240)V DC/AC 99.02.0.230.59 LED + Diode (+A1, standard polarity) (6...24)V DC 99.02.9.024.99 LED + Diode (+A1, standard polarity) (28...60)V DC 99.02.9.060.99 LED + Diode (+A1, standard polarity) (110...220)V DC 99.02.9.220.99 LED + Varistor (6...24)V DC/AC 99.02.0.024.98 LED + Varistor (28...60)V DC/AC 99.02.0.060.98 LED + Varistor (110...240)V DC/AC 99.02.0.230.98 RC circuit  RC circuit (28...60)V DC/AC 99.02.0.060.09 RC circuit (110...240)V DC/AC 99.02.0.230.09 Residual current by-pass 14 (6...24)V DC/AC 99.02.0.024.09 (110...240)V AC 99.02.8.230.07 II-2018, www.findernet.com LED(6...24)V DC/AC 99.02.0.024.59 92 SERIES Sockets and accessories for 62 series relays 92.13 Approvals (according to type): 62 SERIES PCB socket 92.13 (blue) For relay type 62.31, 62.32, 62.33 92.13.0 (black) Accessories A Metal retaining clip (supplied with socket - packaging code SMA) 092.54 Technical data Rated values 10 A - 250 V Dielectric strength 2.5 kV AC Ambient temperature °C –40…+70 62.3x plug on 92.13 is 63.3 mm high 92.33 Approvals (according to type): Panel mount solder socket mounted with M3 screw 92.33 (blue) For relay type 62.31, 62.32, 62.33 Accessories Metal retaining clip (supplied with socket - packaging code SMA) 092.54 Technical data Rated values Dielectric strength Ambient temperature 10 A - 250 V 2.5 kV AC °C –40…+70 Packaging codes How to code and identify retaining clip and packaging options for sockets. Example: 9 2 . 0 3 S M A A Standard packaging II-2018, www.findernet.com SM Metal retaining clip 9 2 . 0 3 Please see general technical information Without retaining clip 15
62.83.9.012.0000 价格&库存

很抱歉,暂时无法提供与“62.83.9.012.0000”相匹配的价格&库存,您可以联系我们找货

免费人工找货
62.83.9.012.0000
  •  国内价格
  • 1+130.40449
  • 2+104.85541
  • 4+99.14191
  • 100+97.81235

库存:32

62.83.9.012.0000
  •  国内价格 香港价格
  • 1+128.313161+15.52620
  • 5+117.573715+14.22670
  • 30+106.9276430+12.93850
  • 100+96.18818100+11.63900

库存:32

62.83.9.012.0000
    •  国内价格
    • 1+259.60019
    • 2+212.24069
    • 3+200.83933

    库存:32