High Power relay 100 A
Power
generators
Back-up
generators
Pump
control
Disabled lift
Inverter
Charging
Stations
FINDER reserves the right to alter characteristics at any time without notice. FINDER assumes no liability for damage to persons or property, caused as a result of the incorrect use or application of its products.
68
68 SERIES
High Power relay 100 A
SERIES
68.22-4300
Printed circuit mount - 3.6 mm contact gap
Relay for applications with high power
Type 68.22-4300
- 2 NO
A
• Contact gap ≥ 3.6 mm (according to
VDE 0126-1-1, EN 62109-1, EN 62109-2)
• DC coils, with only 700 mW holding power
• Reinforced insulation between coil and
contacts
• Suitable for use at ambient temperatures up
• 2 NO
• Contact gap 3.6 mm
• PCB mount
to 85 °C
• Meets the EN 60335-1 requirements of
resistance to heat and fire (GWIT 775 °C and
GWFI 850 °C)
• Cadmium free contact materials
For outline drawing see page 6
Copper side view
Contact specification
Contact configuration
2 NO
Contact gap
mm
Rated current/
Maximum peak current (for 1 ms)
Rated voltage/
Maximum switching voltage
≥ 3.6
A
100/300
V AC
400/690
Rated load AC1/AC7a (per pole)
VA
40000
Rated load AC15 (per pole @ 230 V AC)
VA
4600
Single-phase motor rating (230 V AC)
kW
2.2
Three-phase motor rating (480 V AC)
kW
Breaking capacity DC1: 24/110/220 V
A
Minimum switching load
mW (V/mA)
Standard contact material
—
100/5/1.2
1000 (10/10)
AgSnO2
Coil specification
Nominal voltage (UN)V DC
Rated power
Operating range (–40…+70°C)
12 - 24
W
2.9
DC
(0.90 …1.1)UN
Energy-saving mode (–40…+85)°C
Operating range for 1 s
Holding voltage range
Minimum holding power
(0.95…2.5)UN
DC
0.5 UN
W
0.7
DC
0.05 UN
Mechanical life
cycles
1 · 106
Electrical life at rated load AC7a
cycles
30 · 103
Must drop-out voltage
X-2021, www.findernet.com
Technical data
Operate/release time
Ambient temperature range
(energy-saving mode)
Environmental protection
ms
25/3
°C
–40…+70 (–40…+85)
RT II
Approvals (according to type)
3
68
68 SERIES
High Power relay 100 A
SERIES
Ordering information
Example: 68 series, power relay for printed circuit, 2 NO contacts, 12 V DC coil.
A
6 8 . 2
A
B
C
D
2 . 9 . 0 1 2 . 4
3
0
0
Series
Type
2 = 3-phase PCB terminals,
1.5 mm gap between PCB and relay base
No. of poles
2 = 2 pole
A: Contact material
4 = Standard AgSnO2
D: Special versions
0 = Standard
B: Contact circuit
3 = NO, ≥ 3.6 mm contact gap
C: Options
0 = None
Coil version
9 = DC
Coil voltage
See coil specifications
Technical data
Insulation according to EN 61810-1
Nominal voltage of supply system
V AC 400/690 3-phase
Rated insulation voltage
V AC 630
Pollution degree
3
Insulation between coil and contact set
Type of Insulation
Reinforced
Overvoltage category
III
Rated impulse voltage
kV (1.2/50 µs) 6
Dielectric strength
V AC 5000
Insulation between adjacent contacts
Type of Insulation
Basic
Overvoltage category
III
Rated impulse voltage
kV (1.2/50)µs 6
Dielectric strength
V AC 4000
Insulation between open contacts
Type of disconnection
Full-disconnection
Overvoltage category
III
Rated impulse voltage
kV (1.2/50)µs 4
Dielectric strength
V AC 2500
Insulation between coil terminals
Rated impulse voltage (surge) differential mode
(according to EN 61000-4-5)
kV (1.2/50 µs) 4
Other data
ms 2
Vibration resistance (10…150)Hz: NO
g 9
Shock resistance
g 30
Power lost to the environment
without contact current
W 2.9
with rated current
W 13
Test procedure
Recommended distance between relays mounted on
PCB in case of group mounting
B (single mounting)
mm ≥ 20
Short circuit protection
Rated conditional short circuit current
Back-up fuse for motor load
4
kA 5
A 63 (delayed type)
X-2021, www.findernet.com
Bounce time: NO
68
68 SERIES
High Power relay 100 A
SERIES
Contact specification
F 68 - Electrical life v contact current
A
Cycles
AC7a
AC1
NOTE: for ambient temperatures between 70 and 85 ° C, the electrical life
is reduced by 30%
DC breaking current (A)
H 68 - Maximum DC breaking capacity
DC1
DC13
L/R=100 ms
DC voltage (V)
When switching a resistive (DC1) or inductive (DC13) load having voltage
and current values under the corresponding curve, an electrical life of
> 30000 cycles can be expected.
X-2021, www.findernet.com
NOTE: The heating and electrical endurance tests have been performed
on relays soldered on PC boards having the following characteristics:
double side, copper thickness >105 μm, contact tracks width
40 to 45 mm, total cross section about 10 mm2
5
68
68 SERIES
High Power relay 100 A
SERIES
Coil specifications
DC coil data
Nominal
voltage
A
Coil code
Operating range
(@ 70 °C max)
Holding
voltage
Resistance
Rated coil
consumption I
at UN
UN
Umin
Umax
Uh
R
IN
V
V
V
V
Ω
mA
12
9.012
10.8
13.2
6.0
50
240
24
9.024
21.6
26.4
12.0
200
120
R 68-1 - Operating range v ambient temperature,
with standard (continuous) coil energization (–40…+70)°C
1 - Max. permitted coil voltage.
2 - Min. pick-up voltage with coil at ambient temperature.
R 68-2 - Operating range v ambient temperature,
in energy saving mode (–40…+85)°C
Operating range for < 1 s
Energy saving mode
In some applications, such as photovoltaic inverters, it may be
necessary to minimize the overall relay power dissipation and to permit
use at higher ambient temperature levels (up to 85 °C). This can be
achieved by initially applying a coil voltage within the Energy saving
mode Operating range (see diagram to the left) and then rapidly (