60
SERIES
60 Series - General purpose relays 6 - 10 A
Features
60.12
60.13
Plug-in mount
10 A General purpose relay
2 & 3 pole changeover contacts
• Cadmium Free contacts (preferred version)
• AC coils & DC coils
• UL Listing (certain relay/socket combinations)
• Contact material options
• Lockable test button with mechanical flag
indicator (preferred version)
• 90 series sockets
• Coil EMC suppression
• Timer accessories 86 series
• European Patent
A
•
•
•
2 pole, 10 A power contacts
8 pin plug-in
•
•
3 pole, 10 A power contacts
11 pin plug-in
FOR UL RATINGS SEE:
“General technical information” page V
Contact specification
Contact configuration
2 CO (DPDT)
Rated current/Maximum peak current
A
Rated voltage/Maximum switching voltage V AC
3 CO (3PDT)
10/20
10/20
250/400
250/400
Rated load AC1
VA
2,500
2,500
Rated load AC15 (230 V AC)
VA
500
500
Single phase motor rating (230 V AC)
kW
Breaking capacity DC1: 30/110/220 V
Minimum switching load
A
mW (V/mA)
Standard contact material
0.37
0.37
10/0.4/0.15
10/0.4/0.15
500 (10/5)
500 (10/5)
AgNi
AgNi
Coil specification
Nominal voltage (UN)
V AC (50/60 Hz)
6 - 12 - 24 - 48 - 60 - 110 - 120 - 230 - 240 - 400
6 - 12 - 24 - 48 - 60 - 110 -125 - 220
V DC
Rated power AC/DC
Operating range
VA (50 Hz)/W
AC
2.2/1.3
2.2/1.3
(0.8…1.1)UN
(0.8…1.1)UN
(0.8…1.1)UN
(0.8…1.1)UN
Holding voltage
AC/DC
0.8 UN/0.5 UN
0.8 UN/0.5 UN
Must drop-out voltage
AC/DC
0.2 UN/0.1 UN
0.2 UN/0.1 UN
20 · 106/50 · 106
20 · 106/50 · 106
DC
Technical data
Mechanical life AC/DC
Electrical life at rated load AC1
IV-2014, www.findernet.com
Operate/release time
cycles
cycles
ms
Insulation between coil and contacts (1.2/50 µs) kV
Dielectric strength between open contacts V AC
Ambient temperature range
Environmental protection
°C
3
200 · 10
200 · 103
11/4
11/4
4
3.6
1,000
1,000
–40…+70
–40…+70
RT I
RT I
Approvals (according to type)
1
60
SERIES
60 Series - General purpose relays 6 - 10 A
Features
60.13 - 5200
Plug-in mount - 6 A
Bifurcated contacts for low level switching
2 & 3 pole changeover contacts
Cadmium Free contacts
(Gold plated Silver Nickel)
• AC coils & DC coils
• Lockable test button with mechanical flag
indicator (preferred version)
• 90 series sockets
• Coil EMC suppression
• Timer accessories 86 series
• European Patent
•
•
•
•
2 pole, 6 A bifurcated contacts
8 pin plug-in
•
•
3 pole, 6 A bifurcated contacts
11 pin plug-in
FOR UL RATINGS SEE:
“General technical information” page V
Contact specification
2 CO (DPDT)
Contact configuration
Rated current/Maximum peak current
A
Rated voltage/Maximum switching voltage V AC
3 CO (3PDT)
6/10
6/10
250/400
250/400
Rated load AC1
VA
1,500
1,500
Rated load AC15 (230 V AC)
VA
250
250
Single phase motor rating (230 V AC)
kW
Breaking capacity DC1: 30/110/220 V
Minimum switching load
A
mW (V/mA)
Standard contact material
0.185
0.185
6/0.3/0.12
6/0.3/0.12
50 (5/5)
50 (5/5)
AgNi + Au bifurcated contacts
AgNi + Au bifurcated contacts
Coil specification
Nominal voltage (UN)
V AC (50/60 Hz)
6 - 12 - 24 - 48 - 60 - 110 - 120 - 230 - 240 - 400
6 - 12 - 24 - 48 - 60 - 110 -125 - 220
V DC
Rated power AC/DC
VA (50 Hz)/W
Operating range
AC
DC
2.2/1.3
2.2/1.3
(0.8…1.1)UN
(0.8…1.1)UN
(0.8…1.1)UN
(0.8…1.1)UN
Holding voltage
AC/DC
0.8 UN/0.5 UN
0.8 UN/0.5 UN
Must drop-out voltage
AC/DC
0.2 UN/0.1 UN
0.2 UN/0.1 UN
Technical data
Mechanical life AC/DC
cycles
20 · 106/50 · 106
20 · 106/50 · 106
Electrical life at rated load AC1
cycles
250 · 103
250 · 103
11/4
11/4
4
3.6
Operate/release time
ms
Insulation between coil and contacts (1.2/50 µs) kV
Dielectric strength between open contacts
Ambient temperature range
Environmental protection
Approvals (according to type)
2
V AC
°C
1,000
1,000
–40…+70
–40…+70
RT I
RT I
IV-2014, www.findernet.com
A
60.12 - 5200
60
SERIES
60 Series - General purpose relays 6 - 10 A
Features
60.62
60.63
Flange mount - General purpose relay 10 A
A
Faston 187, 4.8x0.8 mm
2 & 3 pole changeover contacts
• AC coils & DC coils
• Cadmium Free contacts
• Contacts material options
•
•
•
•
2 pole, 10 A power contacts
Flange mount/Faston 187
•
•
3 pole, 10 A power contacts
Flange mount/Faston 187
FOR UL RATINGS SEE:
“General technical information” page V
Contact specification
2 CO (DPDT)
Contact configuration
Rated current/Maximum peak current
A
Rated voltage/Maximum switching voltage V AC
3 CO (3PDT)
10/20
10/20
250/400
250/400
Rated load AC1
VA
2,500
2,500
Rated load AC15 (230 V AC)
VA
500
500
Single phase motor rating (230 V AC)
kW
Breaking capacity DC1: 30/110/220 V
Minimum switching load
A
mW (V/mA)
Standard contact material
0.37
0.37
10/0.4/0.15
10/0.4/0.15
500 (10/5)
500 (10/5)
AgNi
AgNi
Coil specification
Nominal voltage (UN)
V AC (50/60 Hz)
6 - 12 - 24 - 48 - 60 - 110 - 120 - 230 - 240 - 400
6 - 12 - 24 - 48 - 60 - 110 -125 - 220
V DC
Rated power AC/DC
VA (50 Hz)/W
Operating range
AC
DC
2.2/1.3
2.2/1.3
(0.8…1.1)UN
(0.8…1.1)UN
(0.8…1.1)UN
(0.8…1.1)UN
Holding voltage
AC/DC
0.8 UN/0.5 UN
0.8 UN/0.5 UN
Must drop-out voltage
AC/DC
0.2 UN/0.1 UN
0.2 UN/0.1 UN
20 · 106/50 · 106
20 · 106/50 · 106
Technical data
Mechanical life AC/DC
Electrical life at rated load AC1
IV-2014, www.findernet.com
Operate/release time
cycles
cycles
ms
Insulation between coil and contacts (1.2/50 µs) kV
Dielectric strength between open contacts
Ambient temperature range
Environmental protection
V AC
°C
3
200 · 10
200 · 103
11/4
11/4
4
3.6
1,000
1,000
–40…+70
–40…+70
RT I
RT I
Approvals (according to type)
3
60
SERIES
60 Series - General purpose relays 6 - 10 A
Ordering information
Example: 60 series plug-in relay, 3 CO (3PDT), 12 V DC coil, test button and mechanical indicator.
A
6 0 . 1
A
B
C
D
3 . 9 . 0 1 2 . 0
0
4
0
Series
A: Contact material
0 = Standard
5 = AgNi + Au
Type
1 = 8/11 pin plug-in
6 = Faston 187 (4.8x0.8 mm)
with flange mount
B: Contact circuit
0 = CO (nPDT)
2 = Bifurcated contacts
60.12/13 - 6 A only
No. of poles
2 = 2 pole
3 = 3 pole
Coil version
4 = Current sensing (60.12/13 only)
8 = AC (50/60 Hz)
9 = DC
Coil voltage
See coil specifications
Selecting features and options: only combinations in the same row are possible.
Preferred selections for best availability are shown in bold.
Type
Coil version
60.12/13 AC
AC
AC
AC
DC
DC
DC
DC
current sensing
60.62/63 AC-DC
A
0
0
5
5
0
0
5
5
0
0-5
B
0
0
000
0
000
0
2
2
2
2
C
0-2-3-4-5
54
0-2-3-4-5
54
0-2-4-6-7
74
0-2-4-6-7
74
4
0
D: Special versions
0 = Standard
C: Options
0 = None
2 = Mechanical indicator
3 = LED (AC)
4 = Lockable test button +
mechanical indicator
5* = Lockable test button + LED (AC)
54* = Lockable test button + LED (AC) +
mechanical indicator
6* = LED + diode (DC, polarity positive
to pin 2)
7* = Lockable test button + LED + diode
(DC, polarity positive to pin 2)
74* = Lockable test button + LED + diode
(DC, polarity positive to pin 2) +
mechanical indicator
* Options not available for 220 V DC and
400 V AC versions.
D
0
/
0
/
0
/
0
/
0
0
Descriptions: Options and Special versions
2
4
N
T E
T
The dual-purpose Finder test button can be used in two ways:
Case 1) The plastic pip (located directly above the test button) remains intact. In this case, when the
test button is pushed, the contacts operate. When the test button is released the contacts return to their
former state.
Case 2) The plastic pip is broken-off (using an appropriate cutting tool). In this case, (in addition to
the above function), when the test button is pushed and rotated, the contacts are latched in the
operating state, and remain so until the test button is rotated back to its former position.
In both cases ensure that the test button actuation is swift and decisive.
IV-2014, www.findernet.com
3
P A
PEAN
PEAN
Lockable test button and mechanical flag indicator (0040, 0050, 0054, 0070, 0074)
1
O
EUR
EUR
C: Option 6, 7, 74
LED + diode (DC, polarity
positive to pin 2)
O
C: Option 3, 5, 54
LED (AC)
60
SERIES
60 Series - General purpose relays 6 - 10 A
Technical data
Insulation according to EN 61810-1
Nominal voltage of supply system
V AC
Rated insulation voltage
V AC
Pollution degree
Insulation between coil and contact set
Type of insulation
Overvoltage category
Rated impulse voltage
kV (1.2/50 µs)
Dielectric strength
V AC
Insulation between adjacent contacts
Type of insulation
Overvoltage category
Rated impulse voltage
kV (1.2/50 µs)
Dielectric strength
V AC
Insulation between open contacts
Type of disconnection
Dielectric strength
V AC/kV (1.2/50 µs)
Conducted disturbance immunity
Burst (5...50)ns, 5 kHz, on A1 - A2
Surge (1.2/50 µs) on A1 - A2 (differential mode)
Other data
Bounce time: NO/NC
ms
Vibration resistance (5…55)Hz: NO/NC
g
Shock resistance
g
Power lost to the environment
without contact current
W
with rated current
W
2 pole
230/400
250
3
3 pole
230/400
250
3
400
2
A
400
2
Basic
III
4
2,000
Basic
III
3.6
2,000
Basic
III
4
2,000
Basic
III
3.6
2,000
Micro-disconnection
1,000/1.5
Micro-disconnection
1,000/1.5
EN 61000-4-4
EN 61000-4-5
level 4 (4 kV)
level 4 (4 kV)
1/4
22/22
20
1.3
2.7 (60.12, 60.62)
1.3
3.4 (60.13, 60.63)
Contact specification
H 60 - Maximum DC1 breaking capacity
Resistive load - cosϕ = 1
Inductive load - cosϕ = 0.4
contacts in series
DC breaking current (A)
Cycles
F 60 - Electrical life (AC) v contact current
DC voltage (V)
• When switching a resistive load (DC1) having voltage and current
values under the curve, an electrical life of ≥ 100·103 can be expected.
• In the case of DC13 loads, the connection of a diode in parallel with
the load will permit a similar electrical life as for a DC1 load.
Note: the release time for the load will be increased.
AC coil data
Coil specifications
IV-2014, www.findernet.com
DC coil data
Nominal
voltage
UN
V
6
12
24
48
60
110
125
220
Coil
code
9.006
9.012
9.024
9.048
9.060
9.110
9.125
9.220
Operating range
Umin
V
4.8
9.6
19.2
38.4
48
88
100
176
Umax
V
6.6
13.2
26.4
52.8
66
121
138
242
Resistance Rated coil
consumption
R
I at UN
Ω
mA
28
214
110
109
445
53.9
1,770
27.1
2,760
21.7
9,420
11.7
12,000
10.4
37,300
5.8
Nominal
voltage
UN
V
6
12
24
48
60
110
120
230
240
400
Coil
code
8.006
8.012
8.024
8.048
8.060
8.110
8.120
8.230
8.240
8.400
Operating range
Umin
V
4.8
9.6
19.2
38.4
48
88
96
184
192
320
Umax
V
6.6
13.2
26.4
52.8
66
121
132
253
264
440
Resistance Rated coil
consumption
R
I at UN (50Hz)
Ω
mA
4.6
367
19
183
74
90
290
47
450
37
1,600
20
1,940
18.6
7,250
10.5
8,500
9.2
19,800
6
5
60
SERIES
60 Series - General purpose relays 6 - 10 A
Coil specifications
R 60 - DC coil operating range v ambient temperature
R 60 - AC coil operating range v ambient temperature
1 - Max. permitted coil voltage.
2 - Min. pick-up voltage with coil at ambient temperature.
1 - Max. permitted coil voltage.
2 - Min. pick-up voltage with coil at ambient temperature.
A
Current sensing version
Current sensing DC coil data
Coil code
4202
4182
4162
4142
4122
4102
4092
4062
4032
4012
L
N
Imin (A)
1.7
1.5
1.4
1.2
1.0
0.85
0.8
0.5
0.25
0.085
IN (A)
2.0
1.8
1.6
1.4
1.2
1.0
0.9
0.6
0.3
0.1
Imax (A)
2.4
2.2
1.9
1.7
1.4
1.2
1.1
0.7
0.4
0.15
R (Ω)
0.15
0.19
0.24
0.31
0.42
0.61
0.75
1.70
6.70
61
IN (A)
2.5
1.8
1.6
1.2
1.0
0.5
0.4
0.3
0.2
0.1
Imax (A)
3.0
2.2
1.9
1.4
1.2
0.6
0.5
0.4
0.25
0.15
R (Ω)
0.05
0.10
0.12
0.22
0.32
1.28
2.00
3.57
8.0
32.1
Current sensing AC coil data
Typical application with current sensing relays.
An open circuit filiment of lamp L1 is detected by the current sensing
relay coil (K1) which causes the back-up safety lamp L2 to be energised,
and indication of failure at the control panel via lamp S1.
Example: navigation light.
L1 = Light
L2 = Safety light
S1 = Control light
K1 = Relay
Coil code
4251
4181
4161
4121
4101
4051
4041
4031
4021
4011
Imin (A)
2.1
1.5
1.4
1.0
0.85
0.42
0.34
0.25
0.17
0.085
Other types of current sensing relays are available on request.
Sheet of marker tags for relay types 60.12 and 60.13, plastic, 72 tags, 6x12 mm
060.72
6
060.72
IV-2014, www.findernet.com
Accessories
90 Series - Socket overview for 60 series relays
Module Socket
99.02 90.02
90.03
Relay Description
60.12 Screw terminal (Box clamp) socket
60.13 Double A1 terminal
Mounting
Panel or 35 mm rail
(EN 60715) mount
Accessories
- Coil indication and EMC
suppression modules
- Jumper link
- Timer modules
- Metal retaining clip
Module Socket
99.01 90.20
90.21
Relay Description
60.12 Screw terminal (Box clamp) socket
60.13
Mounting
Panel or 35 mm rail
(EN 60715) mount
Accessories
- Coil indication and EMC
suppression modules
- Metal retaining clip
Module Socket Relay Description
— 90.82.3 60.12 Screw terminal (Box clamp) socket
— 90.83.3 60.13
Mounting
Panel or 35 mm rail
(EN 60715) mount
Accessories
- Metal retaining clip
Module Socket
—
90.22
—
90.23
Relay Description
60.12 Screw terminal (Box clamp) socket
60.13
Mounting
Panel or 35 mm rail
(EN 60715) mount
Accessories
- Metal retaining clip
Module Socket
—
90.26
—
90.27
Relay Description
60.12 Screw terminal (Plate clamp) socket
60.13
Mounting
Panel or 35 mm rail
(EN 60715) mount
Accessories
- Metal retaining clip
Module Socket
—
90.12
—
90.13
Relay Description
60.12 Flange mount solder socket
60.13
Mounting
M3 screw fixing
Accessories
—
Module
—
—
—
—
Relay Description
60.12 PCB socket
60.12
60.13
60.13
Mounting
PCB
Accessories
—
90.03
60
SERIES
A
See page 8
90.21
See page 9
90.83.3
See page 10
90.23
See page 10
90.26
See page 11
90.12
See page 1
90.15
IV-2014, www.findernet.com
See page 12
Socket
90.14
90.14.1
90.15
90.15.1
7
60
SERIES
Screw terminal (Box clamp) socket
panel or 35 mm rail (EN 60715) mount
For relay type
Accessories
Metal retaining clip
90.03
6-way jumper link
Identification tag
Approvals
(according to type):
Modules (see table below)
Timer modules (see table below)
Technical data
Rated values
Dielectric strength
Protection category
Certain relay/socket
Ambient temperature
combinations
Screw torque
Wire strip length
Max. wire size for 90.02 and 90.03 sockets
90.02
Blue
60.12
N
T E
PEAN
090.06
86.00
86.30
99.02
Approvals
(according to type):
DC Modules with
non-standard polarity
(+A2) on request.
8
90.03.0
Black
°C
Nm
mm
10 A - 250 V
2 kV AC
IP 20
–40...+70
0.6
10
solid wire
1x6 / 2x2.5
1x10 / 2x14
stranded wire
1x4 / 2x2.5
1x12 / 2x14
T
6-way jumper link for 90.02 and 90.03 sockets
Rated values
090.06 (blue)
10 A - 250 V
090.06.0 (black)
Approvals
(according to type):
86 series timer modules
Multi-voltage: (12…240)V AC/DC;
Multi-functions: AI, DI, SW, BE, CE, DE, EE, FE; (0.05 s…100 h)
(12…24)V AC/DC; Bi-function: AI, DI; (0.05 s…100 h)
(110...125)V AC; Bi-function: AI, DI; (0.05s…100h)
86.00.0.240.0000
86.30.0.024.0000
86.30.8.120.0000
(230...240)V AC; Bi-function: AI, DI; (0.05 s…100 h)
86.30.8.240.0000
Approvals (according to type):
99.02 coil indication and EMC suppression modules for 90.02 and 90.03 sockets
Diode (+A1, standard polarity)
(6...220)V DC 99.02.3.000.00
LED
(6...24)V DC/AC 99.02.0.024.59
LED
(28...60)V DC/AC 99.02.0.060.59
LED
(110...240)V DC/AC 99.02.0.230.59
LED + Diode (+A1, standard polarity)
(6...24)V DC 99.02.9.024.99
LED + Diode (+A1, standard polarity)
(28...60)V DC 99.02.9.060.99
LED + Diode (+A1, standard polarity)
(110...220)V DC 99.02.9.220.99
LED + Varistor
(6...24)V DC/AC 99.02.0.024.98
LED + Varistor
(28...60)V DC/AC 99.02.0.060.98
LED + Varistor
(110...240)V DC/AC 99.02.0.230.98
RC circuit
(6...24)V DC/AC 99.02.0.024.09
RC circuit
(28...60)V DC/AC 99.02.0.060.09
RC circuit
(110...240)V DC/AC 99.02.0.230.09
Residual current by-pass
(110...240)V AC 99.02.8.230.07
IV-2014, www.findernet.com
P A
90.03
Blue
60.13
PEAN
EUR
EUR
O
90.02.0
Black
090.33
090.06
090.00.2
99.02
86.00, 86.30
mm2
AWG
O
A
90 Series - Sockets and accessories for 60 series relays
60
SERIES
90 Series - Sockets and accessories for 60 series relays
90.21
Approvals
(according to type):
Screw terminal (Box clamp) socket
panel or 35 mm rail (EN 60715) mount
For relay type
Accessories
Metal retaining clip (supplied with socket - packaging code SMA)
Modules (see table below)
Technical data
Rated values
Dielectric strength
Protection category
Ambient temperature
°C
Screw torque
Nm
Wire strip length
mm
Max. wire size for 90.20 and 90.21 sockets
mm2
AWG
90.20
99.01
Approvals
(according to type):
* Modules in Black
housing are
available on request.
90.20.0
Black
90.21
Blue
60.13
90.21.0
Black
A
090.33
99.01
10 A - 250 V
2 kV AC
IP 20
–40…+70
0.5
10
solid wire
1x6 / 2x2.5
1x10 / 2x14
stranded wire
1x6 / 2x2.5
1x10 / 2x14
90.21
99.01 coil indication and EMC suppression modules for 90.20 and 90.21 sockets
See technical data page 215/216
Diode (+A1, standard polarity)
(6...220)V DC
Diode (+A2, non-standard polarity)
(6...220)V DC
LED
(6...24)V DC/AC
LED
(28...60)V DC/AC
LED
(110...240)V DC/AC
LED + Diode (+A1, standard polarity)
(6...24)V DC
LED + Diode (+A1, standard polarity)
(28...60)V DC
LED + Diode (+A1, standard polarity)
(110...220)V DC
LED + Diode (+A2, non-standard polarity)
(6...24)V DC
LED + Diode (+A2, non-standard polarity)
(28...60)V DC
LED + Diode (+A2, non-standard polarity)
(110...220)V DC
LED + Varistor
(6...24)V DC/AC
LED + Varistor
(28...60)V DC/AC
LED + Varistor
(110...240)V DC/AC
RC circuit
(6...24)V DC/AC
RC circuit
(28...60)V DC/AC
RC circuit
(110...240)V DC/AC
Residual current by-pass
(110...240)V AC
Blue*
99.01.3.000.00
99.01.2.000.00
99.01.0.024.59
99.01.0.060.59
99.01.0.230.59
99.01.9.024.99
99.01.9.060.99
99.01.9.220.99
99.01.9.024.79
99.01.9.060.79
99.01.9.220.79
99.01.0.024.98
99.01.0.060.98
99.01.0.230.98
99.01.0.024.09
99.01.0.060.09
99.01.0.230.09
99.01.8.230.07
IV-2014, www.findernet.com
Green LED is standard.
Red LED available on
request.
90.20
Blue
60.12
9
SERIES
90 Series - Sockets and accessories for 60 series relays
A
90.83.3
Approvals
(according to type):
Screw terminal (Box clamp) socket
panel or 35 mm rail (EN 60715) mount
For relay type
Accessories
Metal retaining clip
Technical data
Rated values
Dielectric strength
Protection category
Ambient temperature
Screw torque
Max. wire size for 90.82.3 and 90.83.3 sockets
90.82.3
Blue
60.12
90.23
10 A - 250 V
2 kV AC
IP 20
°C –40…+70
Nm 0.8
solid wire
mm2 1x6 / 2x4
AWG 1x10 / 2x14
Screw (Box clamp) terminal socket
panel or 35 mm rail (EN 60715) mount
For relay type
Accessories
Metal retaining clip (supplied with socket - packaging code SMA)
Technical data
Rated values
Dielectric strength
Protection category
Ambient temperature
°C
Screw torque
Nm
Wire strip length
mm
Max wire size for 90.22 and 90.23 sockets
mm2
AWG
90.22
10
90.83.3
Blue
60.13
90.83.30
Black
090.33
90.82.3
Approvals
(according to type):
90.82.30
Black
stranded wire
1x6 / 2x4
1x10 / 2x14
90.83.3
90.22
Blue
60.12
90.23
Blue
60.13
090.33
10 A - 250 V
2 kV AC
IP 20
–40…+70
0.5
7
solid wire
1x6 / 2x2.5
1x10 / 2x14
stranded wire
1x6 / 2x2.5
1x10 / 2x14
90.23
IV-2014, www.findernet.com
60
60
SERIES
90 Series - Sockets and accessories for 60 series relays
90.26
Approvals
(according to type):
Screw terminal (Plate clamp) socket
panel or 35 mm rail (EN 60715) mount
For relay type
Accessories
Metal retaining clip (supplied with socket - packaging code SMA)
Technical data
Rated values
Dielectric strength
Protection category
Ambient temperature
°C
Screw torque
Nm
Wire strip length
mm
Max. wire size for 90.26 and 90.27 sockets
mm2
AWG
90.12
90.27
Blue
60.13
90.27.0
Black
A
090.33
10 A - 250 V
2 kV AC
IP 20
–40…+70
0.8
10
solid wire
1x4 / 2x2.5
1x12 / 2x14
stranded wire
1x4 / 2x2.5
1x12 / 2x14
90.12 (black)
60.12
°C
90.13 (black)
60.13
10 A - 250 V
2 kV AC
–40…+70
IV-2014, www.findernet.com
Approvals
(according to type):
90.26.0
Black
90.27
90.26
Flange mount solder socket mount with M3 screw
For relay type
Technical data
Rated values
Dielectric strength
Ambient temperature
90.26
Blue
60.12
11
60
SERIES
90 Series - Sockets and accessories for 60 series relays
PCB socket
A
90.15
Approvals
(according to type):
Blue
Blue
For relay type
Technical data
Rated values
Dielectric strength
Ambient temperature
°C
90.14
90.14 (Ø 20.5 mm)
90.14.1 (Ø 17.5 mm)
60.12
90.15 (Ø 22 mm)
90.15.1 (Ø 19 mm)
60.13
10 A - 250 V
2 kV AC
–40…+70
90.15
Packaging code
How to code and identify retaining clip and packaging options for sockets.
Example:
9 0 . 2
1
S M
A
A
Standard packaging
SM Metal retaining clip
1
Without retaining clip
IV-2014, www.findernet.com
9 0 . 2
12