41
SERIES
41 Series - Low profile PCB relays 8 - 12 - 16 A
Features
41.31
41.52
41.61
1 & 2 Pole - Low profile (15.7 mm height)
41.31 - 1 Pole 12 A (3.5 mm pin pitch)
41.52 - 2 Pole 8 A (5 mm pin pitch)
41.61 - 1 Pole 16 A (5 mm pin pitch)
A
PCB mount
- direct or via PCB socket
35 mm rail mount
- via screw and screwless sockets
AC and DC coils
8 mm, 6 kV (1.2/50 μs) isolation, coil-contacts
• Cadmium Free contact materials
• Flux proof: RT II standard, (RT III option)
•
•
FOR UL RATINGS SEE:
“General technical information” page V
3.5 mm contact pin pitch
1 Pole 12 A
• PCB direct or via socket
5 mm contact pin pitch
2 Pole 8 A
• PCB direct or via socket
5 mm contact pin pitch
1 Pole 16 A
• PCB direct or via socket
•
•
•
•
•
•
Copper side view
Copper side view
Copper side view
1 CO (SPDT)
2 CO (DPDT)
1 CO (SPDT)
Contact specification
Contact configuration
Rated current/Maximum peak current
A
12/25
Rated voltage/Maximum switching voltage V AC
250/400
250/400
250/400
8/15
16/30
Rated load AC1
VA
3,000
2,000
4,000
Rated load AC15 (230 V AC)
VA
600
400
750
Single phase motor rating (230 V AC)
kW
Breaking capacity DC1: 30/110/220 V
Minimum switching load
A
mW (V/mA)
0.5
0.3
0.5
12/0.3/0.12
8/0.3/0.12
16/0.3/0.12
300 (5/5)
300 (5/5)
300 (5/5)
AgNi
Standard contact material
AgNi
AgNi
Coil specification
Nominal voltage (UN)
V AC (50/60 Hz)
V DC
Rated power AC/DC
Operating range
24 - 115 - 230
24 - 115 - 230
24 - 115 - 230
5 - 6 - 12 - 24 - 48 - 60 - 110
5 - 6 - 12 - 24 - 48 - 60 - 110
5 - 6 - 12 - 24 - 48 - 60 - 110
0.75/0.4
0.75/0.4
0.75/0.4
AC
(0.8...1.1)UN
(0.8...1.1)UN
(0.8...1.1)UN
DC
VA (50 Hz)/W
(0.7...1.5)UN
(0.7...1.5)UN
(0.7...1.5)UN
Holding voltage
AC/DC
0.8/0.4UN
0.8/0.4 UN
0.8/0.4 UN
Must drop-out voltage
AC/DC
0.15/0.1UN
0.15/0.1 UN
0.15/0.1 UN
Mechanical life AC/DC
cycles
10·106/10·106
10·106/10·106
10·106/10·106
Electrical life at rated load AC1
cycles
60 · 103
60 · 103
50 · 103
Technical data
X-2014, www.findernet.com
Operate/release time
ms
Insulation between coil and contacts (1.2/50 μs) kV
Dielectric strength between open contacts V AC
Ambient temperature range
Environmental protection
°C
8/6
8/6
8/6
6 (8 mm)
6 (8 mm)
6 (8 mm)
1,000
1,000
1,000
–40…+70 (AC); +85 (DC)
–40…+70 (AC); +85 (DC)
–40…+70 (AC); +85 (DC)
RT II
RT II
RT II
Approvals (according to type)
1
41
SERIES
41 Series - Bistable low profile PCB relays 8 - 16 A
Features
41.61.6.xxx
1 & 2 Pole - Polarized bistable, Low profile
(15.7 mm height)
41.52 - 2 Pole 8 A (5 mm pin pitch)
41.61 - 1 Pole 16 A (5 mm pin pitch)
Printed Circuit mount
Polarized bistable relay with 2 coils
10 mm, 6 kV (1.2/50μs) isolation,
coil-contacts
• Cadmium Free contact materials
• Flux proof: RT II standard
•
•
•
•
2 Pole, 8 A
PCB direct mount
•
•
1 Pole, 16 A
PCB direct mount
2 coil version:
A3(+) A2 (−) = Set
A3(+) A1 (−) = Reset
2 coil version:
A3(+) A2 (−) = Set
A3(+) A1 (−) = Reset
Copper side view
Copper side view
2 CO (DPDT)
1 CO (SPDT)
Contact specification
Contact configuration
Rated current/Maximum peak current (IN/Imax) A
8 / 15
16 / 30
Rated voltage/Maximum switching voltage (UN/Umax) V AC
250 / 400
250 / 400
Rated load AC1
VA
2,000
4,000
Rated load AC15 (230 V AC)
VA
350
750
Single phase motor rating (230 V AC)
kW
0.37
0.55
Breaking capacity DC1: 30/110/220 V
Minimum switching load
A
8/0.3/0.12
16/0.3/0.12
mW (V/mA)
500 (5/100)
500 (5/100)
AgSnO2
AgSnO2
Standard contact material
Coil specification
Nominal voltage (UN)
5 - 12 - 24
5 - 12 - 24
Rated power (PN)
V DC
W
0.65
0.65
Operating range
DC
(0.7 ... 1.1)UN
(0.7 ... 1.1)UN
Min. impulse duration
ms
20
20
Max. impulse duration
s
30
30
Technical data
Mechanical life DC
cycles
5·106
5·106
Electrical life at rated load AC1
cycles
30 · 103
30 · 103
10 / 5
10 / 10
Insulation between coil and contacts (1.2/50 μs) kV
6 (10 mm)
6 (10 mm)
Dielectric strength between open contacts V AC
1,000
1,000
–40…+85
–40…+85
RT II
RT II
Operate/release time
Ambient temperature range
Environmental protection
Approvals (according to type)
2
ms
°C
—
X-2014, www.findernet.com
A
41.52.6.xxx
41 Series - Low profile PCB relays (SSR) 3 - 5 A
Features
41.81 - 9024
41
SERIES
41.81 - 8240
Solid State Relays
A
Printed circuit mount:
- direct or via PCB socket
35 mm rail mount:
- via screw or screwless sockets
Single circuit output switching options
- 5 A 24 V DC
- 3 A 240 V AC
• Silent, high speed switching with long
electrical life
• LED indicator
• Low profile (15.7 mm)
• Wash tight: RT III
• 2,500 V AC insulation, input-output
•
•
•
5 A, 24 V DC output switching
PCB or 93 Series sockets
3 A, 240 V AC output switching
Zero crossing switching
• PCB or 93 Series sockets
•
•
Copper side view
Copper side view
1 NO (SPST-NO)
1 NO (SPST-NO)
Output circuit
Contact configuration
Rated current/Maximum peak current (10 ms) A
Rated voltage/Maximum blocking voltage
Switching voltage range
Repetitive peak off-state voltage
5/40
3/40
V
(24/35)DC
(240/—)AC
V
(1.5...24)DC
(12...275)AC
—
600
Vpk
Minimum switching current
mA
1
50
Max. “OFF-state” leakage current
mA
0.01
1
0.3
1.1
Max. “ON-state” voltage drop
V
Input circuit
Nominal voltage
V DC
12
24
12
24
Operating range
V DC
8...17
14...32
8...17
14...32
5.5
9
8.8
9
Control current
Release voltage
Impedance
mA
V DC
Ω
4
9
4
9
1,550
2,600
1,030
2,600
Technical data
Operate/release time
ms
Dielectric strength between input/output V AC
Ambient temperature range
Environmental protection
°C
0.05/0.25
10/10
2,500
2,500
–20...+60
–20...+60
RT III
RT III
X-2014, www.findernet.com
Approvals (according to type)
3
41
SERIES
41 Series - Low profile PCB relays
Ordering information
Electromechanical relay (EMR)
Example: 41 series low-profile PCB relay, 2 CO (DPDT), 24 V DC coil.
4 1 . 5
A
B
C
D
2 . 9 . 0 2 4 . 0
0
1
0
Series
Type
3 = PCB - 3.5 mm pinning
5 = PCB - 5 mm pinning
6 = PCB - 5 mm pinning
No. of poles
1 = 1 pole for
41.31, 12 A
41.61, 16 A
2 = 2 pole for
41.52, 8 A
Coil version
6 = DC bistable, 2 coils
8 = AC
9 = DC
A: Contact material
0 = Standard AgNi
4 = AgSnO2
5 = AgNi + Au
D: Special versions
0 = Flux proof (RT II)
1 = Wash tight (RT III)
6 = Bistable version (RT II)
B: Contact circuit
0 = CO (nPDT)
3 = NO (nPST)
C: Options
0 = Production line 0
1 = Production line 1
Selecting features and options: only combinations in the same row are possible.
Preferred selections for best availability are shown in bold.
Coil voltage
See coil specifications
Type
41.31
41.52
41.61
41.31/52/61
41.52
41.61
Coil version
DC
DC
DC
AC
DC bistable
DC bistable
A
0-4-5
0-5
0-4
0
4
4
B
0
0
0
0
0
0
-3
-3
-3
-3
C
1
1
1
0
1
1
D
0-1
0-1
0-1
0
6
6
Solid state relay (SSR)
Example: 41 series SSR relay, 5 A output, 24 V DC supply.
4 1 . 8
Series
Type
8 = SSR type
1 . 7 . 0 2 4 . 9 0 2 4
Output circuit
9024 = 5 A - 24 V DC
8240 = 3 A - 240 V AC
Output
1 = 1 NO (SPST-NO)
Input circuit
See input specifications
X-2014, www.findernet.com
A
4
41
SERIES
41 Series - Low profile PCB relays
Electromechanical relay
Technical data
A
Insulation according to EN 61810-1
1 pole
1 pole bistable
2 pole
2 pole bistable
Nominal voltage of supply system
V AC 230/400
230/400
230/400
230/400
Rated insulation voltage
V AC 250
400
250
250
400
250
2
2
3
2
2
Pollution degree
3
Insulation between coil and contact set
Type of insulation
Reinforced (8 mm) Reinforced (10 mm) Reinforced (8 mm) Reinforced (10 mm)
Overvoltage category
III
III
III
III
Rated impulse voltage
kV (1.2/50 μs) 6
6
6
6
4,000
4,000
4,000
—
Basic
Basic
III
Dielectric strength
V AC 4,000
Insulation between adjacent contacts
Type of insulation
—
Overvoltage category
—
—
III
Rated impulse voltage
kV (1.2/50 μs) —
—
4
4
V AC —
—
2,000
2,000
Dielectric strength
Insulation between open contacts
Type of disconnection
Micro-disconnection
Dielectric strength
Micro-disconnection
V AC/kV (1.2/50 μs) 1,000/1.5
1,000/1.5
Conducted disturbance immunity
Burst (5...50)ns, 5 kHz, on A1 - A2
EN 61000-4-4
level 4 (4 kV)
Surge (1.2/50 μs) on A1 - A2 (differential mode)
EN 61000-4-5
level 3 (2 kV)
Other data
Bounce time: NO/NC
ms 4/6 (monostable) - 2/10 (bistable)
Vibration resistance (5…55)Hz: NO/NC
Shock resistance
Power lost to the environment
g 15/2 (monostable) - 5/3 (bistable)
g 16 (monostable) - 10 (bistable)
without contact current
with rated current
W 1.7 (41.31)
1.2 (41.52)
1.8 (41.61)
mm ≥ 5
X-2014, www.findernet.com
Recommended distance between relays mounted on PCB
W 0.4 (monostable)
5
41
SERIES
41 Series - Low profile PCB relays
Contact specification
F 41 - Electrical life (AC) v contact current (monostable)
Type 41.52
Resistive load - cosϕ = 1
Inductive load - cosϕ = 0.4
Cycles
Cycles
Resistive load - cosϕ = 1
Inductive load - cosϕ = 0.4
limit for 41.31
H 41- Maximum DC1 breaking capacity
DC breaking current (A)
F 41 - Electrical life (AC) v contact current (bistable)
Cycles
1 pole
2 pole
41.61 limit current
41.31 limit current
41.52 limit current
41.52 - 2 contacts in series
single contact
DC voltage (V)
Coil specifications
• When switching a resistive load (DC1) having voltage and current
values under the curve, an electrical life of ≥ 100·103 can be expected.
• In the case of DC13 loads, the connection of a diode in parallel with
the load will permit a similar electrical life as for a DC1 load.
Note: the release time for the load will be increased.
AC coil data
R 41 - AC coil operating range v ambient temperature
Nominal
voltage
UN
V
24
115
230
Coil
code
Operating range
Umin
V
19.2
92
184
8.024
8.115
8.230
Umax
V
26.4
126.5
253
Resistance Rated coil
consumption
R
I at UN
Ω
mA
350
31.6
8,100
6
32,500
3.2
DC coil data
Nominal
voltage
UN
V
5
6
12
24
48
60
110
Coil
code
Operating range
Umin
V
3.5
4.2
8.4
16.8
33.6
42
77
9.005
9.006
9.012
9.024
9.048
9.060
9.110
Umax
V
7.5
9
18
36
72
90
165
Resistance Rated coil
consumption
R
I at UN
Ω
mA
62
80
90
66.7
360
33.3
1,440
16.7
5,760
8.3
9,000
6.6
24,200
4.5
1 - Max. permitted coil voltage.
2 - Min. pick-up voltage with coil at ambient temperature.
R 41 - DC coil operating range v ambient temperature
DC coil data (bistable)
Nominal
voltage
UN
V
5
12
24
6
Coil
code
6.005
6.012
6.024
Operating range
Set
Umin
V
3.5
8.4
16.8
Reset
Umin
V
3.5
8.4
16.8
Set/Reset
Umax
V
5.5
13.2
26.4
Resistance Rated coil
power
R
Ω
38
220
885
mW
650
650
650
1 - Max. permitted coil voltage.
2 - Min. pick-up voltage with coil at ambient temperature.
X-2014, www.findernet.com
A
F 41 - Electrical life (AC) v contact current (monostable)
Types 41.31/61
41
SERIES
41 Series - Low profile PCB relays
Solid state relay
Technical data
Other data
Power lost to the environment
41.81 - 9024
41.81 - 8240
without current
W
0.25
0.25
with maximum current
W
1.75
3.5
A
Input specification
Input data - DC types
Nominal
voltage
UN
V
12
24
Input
code
7.012
7.024
Operating range
Umin
V
8
14
Umax
V
17
32
Release
voltage
Impedance
V
4
9
Ω
1,550
2,600
Control
current
I at UN
mA
5.5
9
Output specification
Output current
L 41 - Output current v ambient temperature
SSR - 3 A AC output types
X-2014, www.findernet.com
Output current
L 41 - Output current v ambient temperature
SSR - 5 A DC output types
7
41
SERIES
93 Series - Sockets and accessories for 41 series relays
Screw terminal socket 35 mm (EN 60715) mounting
A
93.02
Approvals
(according to type):
Supply voltage
Relay type
Socket type
6 V AC/DC
12 V AC/DC
24 V AC/DC
60 V AC/DC
(110...125)V AC/DC
(220...240)V AC/DC
(230...240)V AC
6 V DC
12 V DC
24 V DC
48 V DC
60 V DC
Accessories
41.52.9.005.0010 or 41.61.9.005.0010
41.52.9.012.0010 or 41.61.9.012.0010
41.52/61.9.024.0010 or 41.81.7.024.xxxx
41.52.9.060.0010 or 41.61.9.060.0010
41.52.9.110.0010 or 41.61.9.110.0010
41.52.9.110.0010 or 41.61.9.110.0010
41.52.9.110.0010 or 41.61.9.110.0010
41.52.9.005.0010 or 41.61.9.005.0010
41.52/61.9.012.0010 or 41.81.7.012.xxxx
41.52/61.9.024.0010 or 41.81.7.024.xxxx
41.52.9.048.0010 or 41.61.9.048.0010
41.52.9.060.0010 or 41.61.9.060.0010
93.02.0.024
93.02.0.024
93.02.0.024
93.02.0.060
93.02.0.125
93.02.0.240
93.02.8.230
93.02.7.024
93.02.7.024
93.02.7.024
93.02.7.060
93.02.7.060
8-way jumper link
Plastic separator
Sheet of marker tags, 72 tags
Technical data
Rated values
Dielectric strength
093.08 (see specification next page)
093.01 (see specification next page)
060.72 (see specification next page)
10 A - 250 V
6 kV (1.2/50 μs) between coil and contacts
Protection category
IP 20
Ambient temperature (UN≤ 60 V/> 60 V) °C –40...+70/–40...+55
Screw torque
Nm 0.5
Wire strip length
mm 8
Max. wire size for 93.02 socket
solid wire
mm2 1x6 / 2x2.5
AWG 1x10 / 2x14
stranded wire
1x4 / 2x2.5
1x12 / 2x14
X-2014, www.findernet.com
Note: Not for bistable relays
8
93 Series - Sockets and accessories for 41 series relays
Screwless terminal socket 35 mm (EN 60715) mounting
Supply voltage
Relay type
41
SERIES
Socket type
A
6 V AC/DC
41.52.9.005.0010 or 41.61.9.005.0010 93.52.0.024
12 V AC/DC
41.52.9.012.0010 or 41.61.9.012.0010 93.52.0.024
24 V AC/DC
41.52/61.9.024.0010 or 41.81.7.024.xxxx 93.52.0.024
60 V AC/DC
41.52.9.060.0010 or 41.61.9.060.0010 93.52.0.060
(110...125)V AC/DC
41.52.9.110.0010 or 41.61.9.110.0010 93.52.0.125
(220...240)V AC/DC
41.52.9.110.0010 or 41.61.9.110.0010 93.52.0.240
(230...240)V AC
41.52.9.110.0010 or 41.61.9.110.0010 93.52.8.230
6 V DC
41.52.9.005.0010 or 41.61.9.005.0010 93.52.7.024
12 V DC
41.52/61.9.012.0010 or 41.81.7.012.xxxx 93.52.7.024
24 V DC
41.52/61.9.024.0010 or 41.81.7.024.xxxx 93.52.7.024
48 V DC
41.52.9.048.0010 or 41.61.9.048.0010 93.52.7.060
60 V DC
41.52.9.060.0010 or 41.61.9.060.0010 93.52.7.060
Accessories
8-way jumper link
093.08 (see table below)
Plastic separator
093.01 (see table below)
Sheet of marker tags, 72 tags
060.72 (see table below)
Technical data
Rated values
10 A - 250 V
Dielectric strength
6 kV (1.2/50 μs) between coil and contacts
Protection category
IP 20
Ambient temperature (UN≤ 60 V/> 60 V) °C –40...+70 /–40...+55
Wire strip length
mm 8
Max. wire size for 93.52 socket
solid wire
stranded wire
93.52
Approvals
(according to type):
mm2
AWG
1x2.5
1x14
1x2.5
1x14
Note: Not for bistable relays
P A
PEAN
N
T E
O
O
T
EUR
EUR
Accessories
8-way jumper link for 93.02 and 93.52 sockets
093.08 (blue)
Rated values
10 A - 250 V
Plastic separator for 93.02 and 93.52 sockets
093.01
093.08.0 (black)
093.08.1 (red)
PEAN
093.08
Approvals
(according to type):
X-2014, www.findernet.com
093.01
Thickness 2 mm, required at the start and the end of a group of interfaces.
Can be used for visual separation group, must be used for:
- protective separation of different voltages of neighbouring PLC interfaces according to VDE 0106-101
- protection of cut jumper links
Sheet of marker tags for 38.x2, plastic, 72 tags, 6x12 mm 060.72
060.72
9
41
SERIES
PCB socket
For relay type
Accessories
Plastic retaining clip
Technical data
Rated values
Dielectric strength
Protection category
Ambient temperature
95.13.2
95.15.2
95.13.2 (blue) 95.13.20 (black) 95.15.2 (blue) 95.15.20 (black)
41.31
41.52, 41.61, 41.81(1)
095.42
10 A - 250 V *
6 kV (1.2/50 μs) between coil and contacts
IP 20
°C –40…+70
* For currents >10 A, contact terminals must be connected in parallel (21 with 11, 24 with 14, 22 with 12).
(1)
With the relay 41.81 the NO change-over contact will be 11-14.
Approvals
(according to type):
13
7.5
41.52
41.81 - 9024
41.61
41.81 - 8240
1.5
3.5
3.5
41.31
30
20
95.13.2
95.15.2
Copper side view
Copper side view
Note: Not for bistable relays
Packaging codes
How to code and identify retaining clip and packaging options for sockets.
Example:
9 5 . 1
3 . 2
S L
A
A
Standard packaging
SL Plastic retaining clip
9 5 . 1
3 . 2
Without retaining clip
X-2014, www.findernet.com
A
93 Series - Sockets and accessories for 41 series relays
10