Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
3613 Multi-Conductor - Enhanced Category 6 Nonbonded-Pair Cable
For more Information
please call
1-800-Belden1
General Description:
CAT6+ (400MHz), 4-Pair, U/UTP-Unshielded, Plenum-CMP, Premise Horizontal Cable, 23 AWG Solid
Bare Copper Conductors, Dual FRPO/FEP Insulation, Patented X-Spline Center Member, Rip Cord,
Flamarrest® PVC jacket.
Usage (Overall)
Suitable Applications:
Premise Horizontal Cable, Gigabit Ethernet, 100BaseTX, 100BaseVG
ANYLAN, 155ATM, 622ATM, NTSC/PAL Component or Composite Video,
AES/EBU Digital Audio, AES51, RS-422, Noisy Environments
Physical Characteristics (Overall)
Conductor
AWG:
# Pairs AWG Stranding Conductor Material
4
23
Solid
BC - Bare Copper
Total Number of Conductors:
8
Insulation
Insulation Material:
Insulation Material
FRPO/FEP - Flame Retardant Polyolefin/Fluorinated Ethylene Propylene
Outer Shield
Outer Shield Material:
Outer Shield Material
Unshielded
Outer Jacket
Outer Jacket Material:
Outer Jacket Trade Name Outer Jacket Material
Flamarrest(R)
Nom. Wall Thickness (mm)
LS PVC - Low Smoke Polyvinyl Chloride 0.432
Outer Jacket Diameter:
Nom. Dia. (mm)
5.969
Outer Jacket Ripcord:
Yes
Overall Cable
Overall Cabling Separator Material:
Patented X-Spline Center Member
Overall Nominal Diameter:
5.969 mm
Pair
Pair Color Code Chart:
Number Color
1
White/Blue Stripe & Blue
2
White/Orange Stripe & Orange
3
White/Green Stripe & Green
4
White/Brown Stripe & Brown
Page 1 of 5
01-10-2014
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
3613 Multi-Conductor - Enhanced Category 6 Nonbonded-Pair Cable
Mechanical Characteristics (Overall)
Storage Temperature Range:
-20°C To +75°C
Installation Temperature Range:
+5°C To +50°C
Operating Temperature Range:
0°C To +75°C
UL Temperature Rating:
75°C
Bulk Cable Weight:
47.622 Kg/Km
Max. Recommended Pulling Tension:
200.169 N
Min. Bend Radius/Minor Axis:
19.050 mm
Min. Bend/Installation:
57.150 mm
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
NEC/(UL) Specification:
CMP
CEC/C(UL) Specification:
CMP
EU Directive 2011/65/EU (ROHS II):
Yes
Other Standards:
ISO/IEC 11801 ed 2.1 (2008) Class E
EU CE Mark:
Yes
EU Directive 2000/53/EC (ELV):
Yes
EU Directive 2002/95/EC (RoHS):
Yes
EU RoHS Compliance Date (mm/dd/yyyy):
04/03/2009
EU Directive 2002/96/EC (WEEE):
Yes
EU Directive 2003/11/EC (BFR):
Yes
CA Prop 65 (CJ for Wire & Cable):
Yes
MII Order #39 (China RoHS):
Yes
Telecommunications Standards:
Category 6 - TIA 568.C.2
Other Specification:
6
Applicable Patents:
Country Patent
US
5563377
US
6074503
US
7663061
US
7977575
US
8536455
Flame Test
UL Flame Test:
NFPA 262
C(UL) Flame Test:
FT6
Suitability
Suitability - Indoor:
Yes
Suitability - Outdoor:
No
Suitability - Aerial:
No
Suitability - Burial:
No
Sunlight Resistance:
No
Plenum/Non-Plenum
Plenum (Y/N):
Yes
Non-Plenum Number:
3612
Page 2 of 5
01-10-2014
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
3613 Multi-Conductor - Enhanced Category 6 Nonbonded-Pair Cable
Electrical Characteristics (Overall)
Nom. Mutual Capacitance:
Capacitance (pF/m)
50.8555
Maximum Capacitance Unbalance (pF/100 m):
330
Nominal Velocity of Propagation:
VP (%)
70.000
Maximum Delay:
Freq. (MHz) Delay (ns/100 m)
100.000
537.600
Typical Delay Skew:
Delay Skew (ns/m)
114.835
Maximum Conductor DC Resistance:
DCR @ 20°C (Ohm/100 m)
7.700
Max. Operating Voltage - UL:
Voltage
300 V RMS
Maximum DCR Unbalanced:
DCR Unbalance @ 20°C (%)
3.000
Electrical Characteristics-Premise (Overall)
Premise Cable Electrical Table 1:
Freq. (MHz) Max. Attenuation (dB/100 m) Min. NEXT (dB) Min. PSNEXT (dB) Min. ACR (dB) Min. PSACR (dB) Min RL (dB)
0.772
1.800
81.0
81.0
79.2
79.2
1
2.000
79.3
79.3
77.3
77.3
20.000
4
3.700
70.3
70.3
66.6
66.6
23.000
8
5.200
65.8
65.8
60.6
60.6
24.500
10
5.800
64.3
64.3
58.5
58.5
25.000
16
7.400
61.2
61.2
53.9
53.9
25.000
20
8.300
59.8
59.8
51.5
51.5
25.000
25
9.300
58.3
58.3
49.1
49.1
24.300
31.25
10.400
56.9
56.9
46.5
46.5
23.600
62.5
15.000
52.4
52.4
37.4
37.4
21.500
100
19.300
49.3
49.3
30.0
30.0
20.800
155
24.600
46.4
46.4
21.8
21.8
19.500
200
28.300
44.8
44.8
16.5
16.5
18.700
250
32.100
43.3
43.3
11.2
11.2
18.000
300
35.600
42.1
42.1
6.5
6.5
17.500
350
38.900
41.1
41.1
2.3
2.3
17.000
400
42.000
38.3
38.3
-3.7
-3.7
16.600
450
45.000
37.5
37.5
16.200
500
47.900
36.8
36.8
15.900
550
50.600
36.2
36.2
15.600
600
53.300
35.6
35.6
15.400
650
55.900
35.1
35.1
15.100
Premise Cable Electrical Table 2:
Freq. (MHz) Input (Unfitted) Imp. (Ohms) Min. ACRF (dB) Min. PSACRF (dB)
.772
75.0
73.0
1
100 ± 15
72.8
70.8
4
100 ± 15
60.8
58.8
8
100 ± 15
54.7
52.7
Page 3 of 5
01-10-2014
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
3613 Multi-Conductor - Enhanced Category 6 Nonbonded-Pair Cable
10
100 ± 15
52.8
50.8
16
100 ± 15
48.7
46.7
20
100 ± 15
46.8
44.8
25
100 ± 15
44.8
42.8
31.25
100 ± 15
42.9
40.9
62.5
100 ± 15
36.9
34.9
100
100 ± 15
32.8
30.8
155
100 ± 22
28.9
26.9
200
100 ± 22
26.8
24.8
250
100 ± 32
24.8
22.8
300
100 ± 32
23.3
21.3
350
100 ± 32
21.9
19.9
400
100 ± 32
20.8
18.8
450
100 ± 32
19.7
17.7
500
100 ± 32
18.8
16.8
550
100 ± 32
18.0
16.0
600
100 ± 32
17.2
15.2
650
100 ± 32
16.5
14.5
Premise Cable Electrical Table 4:
Frequency (MHz) Min. TCL (dB) Min. ELTCTL (dB)
0.772
40.000
37.200
1.000
40.000
35.000
4.000
40.000
23.000
8.000
40.000
16.900
10.000
40.000
15.000
16.000
38.000
10.900
20.000
37.000
9.000
25.000
36.000
7.000
31.250
35.100
62.500
32.000
100.000
30.000
155.000
28.100
200.000
27.000
250.000
26.000
Notes (Overall)
Notes: Jacket sequentially marked at 2 ft./1m intervals. Third party verified to ANSI/TIA-568-C.2 Category 6. Values above 400 MHz
are for engineering information only.
Put Ups and Colors:
Item #
Putup
Ship Weight
Color
3613 D15A1000
305 MT
14.515 KG
BLUE
Notes
CAT6E 4PR U/UTP CMP RIB
3613 D15U1000
305 MT
13.608 KG
BLUE
CAT6E 4PR U/UTP CMP BOX
3613 D151000
305 MT
13.608 KG
BLUE
CAT6E 4PR U/UTP CMP REEL
3613 D152500
762 MT
31.752 KG
BLUE
CAT6E 4PR U/UTP CMP REEL
3613 002A1000
305 MT
14.515 KG
RED
CAT6E 4PR U/UTP CMP RIB
3613 003A1000
305 MT
14.515 KG
ORANGE
CAT6E 4PR U/UTP CMP RIB
3613 003U1000
305 MT
13.608 KG
ORANGE
CAT6E 4PR U/UTP CMP BOX
3613 0031000
305 MT
13.608 KG
ORANGE
CAT6E 4PR U/UTP CMP REEL
3613 004A1000
305 MT
14.515 KG
YELLOW
CAT6E 4PR U/UTP CMP RIB
3613 004U1000
305 MT
13.608 KG
YELLOW
CAT6E 4PR U/UTP CMP BOX
3613 0041000
305 MT
13.608 KG
YELLOW
CAT6E 4PR U/UTP CMP REEL
3613 0042500
762 MT
31.752 KG
YELLOW
CAT6E 4PR U/UTP CMP REEL
3613 005A1000
305 MT
14.515 KG
GREEN, DARK
CAT6E 4PR U/UTP CMP RIB
3613 005U1000
305 MT
13.608 KG
GREEN, DARK
CAT6E 4PR U/UTP CMP BOX
3613 0051000
305 MT
13.608 KG
GREEN, DARK
CAT6E 4PR U/UTP CMP REEL
3613 0052500
762 MT
31.752 KG
GREEN, DARK
CAT6E 4PR U/UTP CMP REEL
3613 007A1000
305 MT
14.515 KG
VIOLET
CAT6E 4PR U/UTP CMP RIB
3613 007U1000
305 MT
13.608 KG
VIOLET
CAT6E 4PR U/UTP CMP BOX
Page 4 of 5
Item Desc
01-10-2014
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
3613 Multi-Conductor - Enhanced Category 6 Nonbonded-Pair Cable
3613 008A1000
305 MT
14.515 KG
GRAY
CAT6E 4PR U/UTP CMP RIB
3613 008U1000
305 MT
13.608 KG
GRAY
CAT6E 4PR U/UTP CMP BOX
3613 0081000
305 MT
13.608 KG
GRAY
CAT6E 4PR U/UTP CMP REEL
3613 009A1000
305 MT
14.515 KG
WHITE
CAT6E 4PR U/UTP CMP RIB
3613 009U1000
305 MT
13.608 KG
WHITE
CAT6E 4PR U/UTP CMP BOX
3613 0091000
305 MT
13.608 KG
WHITE
CAT6E 4PR U/UTP CMP REEL
3613 0092500
762 MT
31.752 KG
WHITE
CAT6E 4PR U/UTP CMP REEL
3613 010A1000
305 MT
14.515 KG
BLACK
CAT6E 4PR U/UTP CMP RIB
3613 010U1000
305 MT
13.608 KG
BLACK
CAT6E 4PR U/UTP CMP BOX
3613 0101000
305 MT
13.608 KG
BLACK
CAT6E 4PR U/UTP CMP REEL
3613 0102500
762 MT
31.752 KG
BLACK
CAT6E 4PR U/UTP CMP REEL
3613 012A1000
305 MT
14.515 KG
PINK
CAT6E 4PR U/UTP CMP RIB
Revision Number: 9
Revision Date: 01-08-2014
© 2014 Belden, Inc
All Rights Reserved.
Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications
described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not
ensure product availability.
Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express,
statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or
exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract,
negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein.
All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the
compliance date may be in stock at Belden facilities and in our Distributor’s inventory. The information provided in this Product Disclosure, and
the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Belden’s knowledge,
information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide
for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not
to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for
determining the applicability of legislation and regulations based on their individual usage of the product.
Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 73/23/EEC), as amended by directive 93/68/EEC.
Page 5 of 5
01-10-2014