0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
7896A T5U2000

7896A T5U2000

  • 厂商:

    BELDEN

  • 封装:

  • 描述:

    CBL 1PR/16AWG 1PR/18AWG SHLD

  • 数据手册
  • 价格&库存
7896A T5U2000 数据手册
Part Number: 7896A DeviceBus® for ODVA DeviceNet™, (1 pr) 16 AWG (19x29) TC & (1 pr) 18 AWG (19x30) TC, PVC-NYL/FRPP/PVC, Foil+Braid Shld, TC-ER Product Description One 16 AWG pair stranded (19x29) tinned copper conductor and one 18 AWG pair stranded (19x30) tinned copper conductors, PVC/Nylon insulation (power), F-R Polypropylene insulation (data), individual foil shield (100% coverage) plus an overall tinned copper braid shield (65% coverage), oil- and UV-resistant PVC jacket. Technical Specifications Physical Characteristics (Overall) Conductor AWG Stranding Material No. of Pairs 16 19x29 TC - Tinned Copper 1 18 19x30 TC - Tinned Copper 1 Conductor Count: 4 AWG Size: 16 Insulation Element Material Nominal Diameter 16 PVC/Nylon - Polyvinyl Chloride/Nylon 18 FRPP - Flame Retardant Polypropylene 0.182 in 0.101 in Color Chart Number Color 1 (16 AWG) Red & Black 2 (18 AWG) Blue & White Inner Shield Material Type Material Material Trade Name Coverage [%] Drainwire Material Tape Aluminum Foil-Polyester Tape Beldfoil® 100 % Outer Shield Material Type Material Coverage [%] Drainwire Construction n x D Braid TC - Tinned Copper 65 % 19x29 mm Outer Jacket Material Material Nominal Diameter Nominal Wall Thickness PVC - Polyvinyl Chloride 0.525 in 0.06 in Construction and Dimensions Stranding Lay Length 1 MHz Electrical Characteristics Conductor DCR Element Nominal Conductor DCR Nominal Outer Shield DCR 16 AWG 4.9 Ohm/1000ft 18 AWG 6.9 Ohm/1000ft 1.8 Ohm/1000ft Drainwire AWG TC - Tinned Copper 16 Capacitance Element Nom. Capacitance Conductor to Conductor 18 AWG Pair Only 14.7 pF/ft Impedance Nominal Characteristic Impedance 100 Ohm 120 Ohm Delay Max. Delay Max. Delay Description Nominal Delay Nominal Velocity of Propagation (VP) [%] Nominal Velocity of Propagation (VP) Description 1.6 ns/ft 18 AWG Pair Only 18 AWG Pair Only 1.6 ns/ft 64 % High Freq Element Frequency [MHz] Max./Min. Input Impedance (unFitted) 18 AWG Pair Only 0.125 MHz 120 Ohm 0.5 MHz Current Element Max. Recommended Current [A] 15 AWG 8.0 Amps per conductor at 25°C Voltage UL Voltage Rating 600V RMS Temperature Range Installation Temp Range: -25°C To +75°C UL Temp Rating: 75°C Operating Temp Range: -40°C To +75°C Mechanical Characteristics Oil Resistance: Yes Bulk Cable Weight: 135 lbs/1000ft Max Recommended Pulling Tension: 190 lbs Min Bend Radius/Minor Axis: 5 in Standards NEC/(UL) Specification: TC-ER CSA AWM Specification: AWM I/II A/B Other Specification: ODVA Cable V Applicable Environmental and Other Programs EU Directive 2000/53/EC (ELV): Yes EU Directive 2011/65/EU (ROHS II): Yes EU Directive 2012/19/EU (WEEE): Yes EU Directive 2015/863/EU: Yes EU Directive Compliance: EU Directive 2003/11/EC (BFR) EU CE Mark: Yes EU RoHS Compliance Date (yyyy-mm-dd): 2005-10-13 CA Prop 65 (CJ for Wire & Cable): Yes MII Order #39 (China RoHS): Yes Suitability Suitability - Oil Resistance: Yes Suitability - Sunlight Resistance: Yes Flammability, LS0H, Toxicity Testing UL Flammability: UL1685 UL Loading CSA Flammability: FT1 Part Number Plenum (Y/N): No Variants Item # Color Footnote 7896A T5U1000 GRAY T5U C 7896A T5U2000 GRAY T5U C 7896A T5U500 GRAY T5U C Footnote: C - CRATE REEL PUT-UP. Product Notes Notes: Meter marks on jacket to aid users in installation. ODVA DeviceNet is an Open DeviceNet Vendor Association, Inc. trademark. © 2018 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described here in are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on an "ASIS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale. Belden believes this product to be in compliance with EU RoHS(Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the compliance date may be instock at Belden facilities and in our Distributor's inventory. The information provided in this Product Disclosure, and the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Belden's knowledge, information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product. Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 73/23/EEC), as amended by directive 93/68/EEC.
7896A T5U2000 价格&库存

很抱歉,暂时无法提供与“7896A T5U2000”相匹配的价格&库存,您可以联系我们找货

免费人工找货