Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
9550 Multi-Conductor - Computer Cable for EIA RS-232 Applications
For more Information
please call
1-800-Belden1
General Description:
24 AWG stranded (7x32) TC conductors, semi-rigid PVC insulation, twisted pairs, overall Beldfoil shield
(100% coverage), 24 AWG stranded TC drain Wire (continued), PVC jacket.
Physical Characteristics (Overall)
Conductor
AWG:
# Pairs AWG Stranding Conductor Material
50
24
7x32
TC - Tinned Copper
Total Number of Conductors:
100
Insulation
Insulation Material:
Insulation Material
Wall Thickness (in.)
S-R PVC - Semi-Rigid Polyvinyl Chloride 0.011
Outer Shield
Outer Shield Material:
Outer Shield Trade Name Type Outer Shield Material
Beldfoil®
Coverage (%)
Tape Aluminum Foil-Polyester Tape w/Shorting Fold 100
Outer Shield Drain Wire AWG:
AWG Stranding Drain Wire Conductor Material
24
7x32
TC - Tinned Copper
Outer Jacket
Outer Jacket Material:
Outer Jacket Material
Nom. Wall Thickness (in.)
PVC - Polyvinyl Chloride 0.054
Overall Cable
Overall Nominal Diameter:
0.708 in.
Pair
Pair Color Code Chart:
Number Color
1
Blue & White
2
Orange & White
3
Green & White
4
Brown & White
5
Gray & White
6
Blue/ White & White
7
Blue/Orange & White
8
Blue/Green & White
9
Blue/Brown & White
10
Blue/Gray & White
11
Orange/White & White
12
Orange/Green & White
13
Orange/Brown & White
14
Orange/Gray & White
15
Green/White & White
16
Green/Brown & White
17
Green/Gray & White
18
Brown/White & White
19
Brown/Gray & White
20
Gray/White & White
21
Blue & Red
22
Orange & Red
23
Green & Red
24
Brown & Red
Page 1 of 3
01-05-2017
Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
9550 Multi-Conductor - Computer Cable for EIA RS-232 Applications
25
Gray & Red
26
Blue/White & Red
27
Blue/Orange & Red
28
Blue/Green & Red
29
Blue/Brown & Red
30
Blue/Gray & Red
31
Orange/White & Red
32
Orange/Green & Red
33
Orange/Brown & Red
34
Orange/Gray & Red
35
Green/White & Red
36
Green/Brown, Red
37
Green/Gray & Red
38
Brown/White & Red
39
Brown/Gray & Red
40
Gray/White & Red
41
Blue & Black
42
Orange & Black
43
Green & Black
44
Brown & Black
45
Gray & Black
46
Blue/White & Black
47
Blue/Orange & Black
48
Blue/Green & Black
49
Blue/Brown & Black
50
Blue/Gray & Black
Mechanical Characteristics (Overall)
Operating Temperature Range:
-30°C To +80°C
Non-UL Temperature Rating:
80°C (UL AWM Style 2464)
Bulk Cable Weight:
286 lbs/1000 ft.
Max. Recommended Pulling Tension:
550 lbs.
Min. Bend Radius/Minor Axis:
7.250 in.
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
NEC/(UL) Specification:
CMG
CEC/C(UL) Specification:
CMG
AWM Specification:
UL Style 2464 (300 V 80°C)
CSA Specification:
AWM I A
EU Directive 2011/65/EU (ROHS II):
Yes
EU CE Mark:
Yes
EU Directive 2000/53/EC (ELV):
Yes
EU Directive 2002/95/EC (RoHS):
Yes
EU RoHS Compliance Date (mm/dd/yyyy):
04/01/2005
EU Directive 2002/96/EC (WEEE):
Yes
EU Directive 2003/11/EC (BFR):
Yes
CA Prop 65 (CJ for Wire & Cable):
Yes
MII Order #39 (China RoHS):
Yes
Flame Test
UL Flame Test:
UL1685 FT4 Loading
C(UL) Flame Test:
FT4
Plenum/Non-Plenum
Plenum (Y/N):
No
Electrical Characteristics (Overall)
Nom. Capacitance Conductor to Conductor:
Capacitance (pF/ft)
30
Page 2 of 3
01-05-2017
Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
9550 Multi-Conductor - Computer Cable for EIA RS-232 Applications
Nom. Capacitance Cond. to Other Conductor & Shield:
Capacitance (pF/ft)
50
Nominal Velocity of Propagation:
VP (%)
60
Nom. Conductor DC Resistance:
DCR @ 20°C (Ohm/1000 ft)
24
Nominal Outer Shield DC Resistance:
DCR @ 20°C (Ohm/1000 ft)
15.2
Max. Operating Voltage - UL:
Voltage
300 V RMS
Max. Recommended Current:
Current
1.1 Amps per conductor @ 25°C
Put Ups and Colors:
Item #
Putup
Ship Weight
Color
Notes
Item Desc
9550 060100
100 FT
31.900 LB
CHROME
C
50 PR #24 PVC FS PVC
9550 0601000
1,000 FT
311.000 LB
CHROME
CD
50 PR #24 PVC FS PVC
9550 060500
500 FT
162.000 LB
CHROME
CD
50 PR #24 PVC FS PVC
Notes:
C = CRATE REEL PUT-UP.
D = FINAL PUT-UP LENGTH MAY VARY -0% TO +20% FROM LENGTH SHOWN.
Revision Number: 2
Revision Date: 08-31-2012
© 2017 Belden, Inc
All Rights Reserved.
Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to
change without notice, and the listing of such information and specifications does not ensure product availability.
Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for
any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether
in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein.
All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the compliance date may be in stock at Belden facilities
and in our Distributor’s inventory. The information provided in this Product Disclosure, and the identification of materials listed as reportable or restricted within the Product Disclosure, is
correct to the best of Belden’s knowledge, information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide for the
safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not to be considered a warranty or quality specification.
Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the
product.
Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 2014/35/EU).
Page 3 of 3
01-05-2017
很抱歉,暂时无法提供与“9550 060100”相匹配的价格&库存,您可以联系我们找货
免费人工找货