Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
9207 Twinax - Twinaxial Cable
For more Information
please call
1-800-Belden1
General Description:
20 AWG stranded (7x28) one tinned copper conductor, one bare copper conductor, polyethylene insulation,
polyethylene inner jacket, Duofoil® (100% coverage) plus a tinned copper braid shield (85% coverage),
PVC outer jacket.
Physical Characteristics (Overall)
Conductor
AWG:
# Pairs AWG Stranding Conductor Material Dia. (in.)
1
20
7x28
TC - Tinned Copper .037
BC - Bare Copper
Total Number of Conductors:
2
Insulation
Insulation Material:
Insulation Material Wall Thickness (in.)
PE - Polyethylene
0.024
Inner Jacket
Inner Jacket Material:
Inner Jacket Material Nom Wall (in.) Nom. Dia. (in.)
PE - Polyethylene
0.035
0.236
Outer Shield
Outer Shield Material:
Layer # Outer Shield Trade Name Type Outer Shield Material
1
Duofoil®
Coverage (%)
Tape Aluminum Foil-Polyester Tape-Aluminum Foil 100
2
Braid TC - Tinned Copper
85
Outer Jacket
Outer Jacket Material:
Outer Jacket Material
Nom. Wall Thickness (in.)
PVC - Polyvinyl Chloride 0.031
Overall Cable
Overall Nominal Diameter:
0.330 in.
Pair
Pair Color Code Chart:
Number Color
1
Natural (bare copper conductor)
2
Natural (tinned copper conductor)
Mechanical Characteristics (Overall)
Operating Temperature Range:
-30°C To +75°C
Bulk Cable Weight:
63 lbs/1000 ft.
Max. Recommended Pulling Tension:
112 lbs.
Min. Bend Radius/Minor Axis:
3.500 in.
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
NEC/(UL) Specification:
CL2, CMG
CEC/C(UL) Specification:
CMG
EU Directive 2011/65/EU (ROHS II):
Yes
EU CE Mark:
Yes
EU Directive 2000/53/EC (ELV):
Yes
Page 1 of 3
08-26-2016
Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
9207 Twinax - Twinaxial Cable
EU Directive 2002/95/EC (RoHS):
Yes
EU RoHS Compliance Date (mm/dd/yyyy):
01/01/2004
EU Directive 2002/96/EC (WEEE):
Yes
EU Directive 2003/11/EC (BFR):
Yes
CA Prop 65 (CJ for Wire & Cable):
Yes
MII Order #39 (China RoHS):
Yes
Customer Part Number Reference Specification:
IBM P/N 7362211
Flame Test
UL Flame Test:
UL1685 FT4 Loading
CSA Flame Test:
FT4
Suitability
Suitability - Indoor:
Yes
Suitability - Outdoor:
Yes
Plenum/Non-Plenum
Plenum (Y/N):
No
Plenum Number:
89207
Electrical Characteristics (Overall)
Nom. Characteristic Impedance:
Impedance (Ohm)
100
Nom. Inductance:
Inductance (µH/ft)
0.155
Nom. Capacitance Conductor to Conductor:
Capacitance (pF/ft)
14.5
Nom. Capacitance Cond. to Other Conductor & Shield:
Capacitance (pF/ft)
23.0
Nominal Velocity of Propagation:
VP (%)
66
Nominal Delay:
Delay (ns/ft)
1.54
Nom. Conductor DC Resistance:
DCR @ 20°C (Ohm/1000 ft)
9.5
Nominal Outer Shield DC Resistance:
DCR @ 20°C (Ohm/1000 ft)
1.74
Nom. Attenuation:
Freq. (MHz) Attenuation (dB/100 ft.)
1
0.3
10
1.2
50
2.8
100
4.1
200
6.4
400
10.2
Max. Operating Voltage - UL:
Voltage
300 V RMS
Max. Operating Voltage - Non-UL:
Voltage
600 V RMS
Put Ups and Colors:
Page 2 of 3
08-26-2016
Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
9207 Twinax - Twinaxial Cable
Item #
Putup
Ship Weight
Color
9207 010U500
500 FT
33.000 LB
BLACK
Notes
Item Desc
9207 010100
100 FT
7.100 LB
BLACK
9207 0101000
1,000 FT
68.000 LB
BLACK
C
100 OHM TWINAX
9207 0101640
1,640 FT
111.520 LB
BLACK
C
100 OHM TWINAX
9207 0103280
3,280 FT
219.760 LB
BLACK
C
100 OHM TWINAX
9207 010500
500 FT
34.500 LB
BLACK
C
100 OHM TWINAX
9207 0105000
5,000 FT
350.000 LB
BLACK
C
100 OHM TWINAX
100 OHM TWINAX
100 OHM TWINAX
Notes:
C = CRATE REEL PUT-UP.
Revision Number: 2
Revision Date: 09-26-2012
© 2016 Belden, Inc
All Rights Reserved.
Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to
change without notice, and the listing of such information and specifications does not ensure product availability.
Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for
any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether
in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein.
All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the compliance date may be in stock at Belden facilities
and in our Distributor’s inventory. The information provided in this Product Disclosure, and the identification of materials listed as reportable or restricted within the Product Disclosure, is
correct to the best of Belden’s knowledge, information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide for the
safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not to be considered a warranty or quality specification.
Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the
product.
Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 2014/35/EU).
Page 3 of 3
08-26-2016
很抱歉,暂时无法提供与“9207 0101640”相匹配的价格&库存,您可以联系我们找货