1212 005U1000

1212 005U1000

  • 厂商:

    BELDEN

  • 封装:

  • 描述:

    CAT5E+ 4PR U/UTP CMR BOX

  • 数据手册
  • 价格&库存
1212 005U1000 数据手册
Detailed Specifications & Technical Data ENGLISH MEASUREMENT VERSION 1212 Multi-Conductor - Enhanced Category 5E Nonbonded-Pair Cable For more Information please call 1-800-Belden1 General Description: CAT5e+ (350MHz), 4-Pair, U/UTP-Unshielded, Riser-CMR, Premise Horizontal Cable, 24 AWG Solid Bare Copper Conductors, Polyolefin Insulation, Ripcord, PVC Jacket. Usage (Overall) Suitable Applications: Premise Horizontal Cable, Gigabit Ethernet, POE, POE+,100BaseTX, 100BaseVG ANYLAN, 155ATM, 622ATM, NTSC/PAL Component or Composite Video, AES/EBU, Digital Video, RS-422 Physical Characteristics (Overall) Conductor AWG: # Pairs AWG Stranding Conductor Material 4 24 Solid BC - Bare Copper Total Number of Conductors: 8 Insulation Insulation Material: Insulation Material PO - Polyolefin Outer Shield Outer Shield Material: Outer Shield Material Unshielded Outer Jacket Outer Jacket Material: Outer Jacket Material PVC - Polyvinyl Chloride Outer Jacket Diameter: Nom. Dia. (in.) 0.205 Outer Jacket Ripcord: Yes Overall Cable Overall Nominal Diameter: 0.205 in. Pair Pair Color Code Chart: Number Color 1 White/Blue Stripe & Blue 2 White/Orange Stripe & Orange 3 White/Green Stripe & Green 4 White/Brown Stripe & Brown Mechanical Characteristics (Overall) Operating Temperature Range: -20°C To +80°C Bulk Cable Weight: 21 lbs/1000 ft. Max. Recommended Pulling Tension: 35 lbs. Min. Bend Radius/Minor Axis: 0.750 in. Min. Bend/Installation: 2 in. Applicable Specifications and Agency Compliance (Overall) Applicable Standards & Environmental Programs NEC/(UL) Specification: CMR NEC Articles: 800 Page 1 of 4 02-01-2017 Detailed Specifications & Technical Data ENGLISH MEASUREMENT VERSION 1212 Multi-Conductor - Enhanced Category 5E Nonbonded-Pair Cable CEC/C(UL) Specification: CMR EU Directive 2011/65/EU (ROHS II): Yes EU CE Mark: Yes EU Directive 2000/53/EC (ELV): Yes EU Directive 2002/95/EC (RoHS): Yes EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2004 EU Directive 2002/96/EC (WEEE): Yes EU Directive 2003/11/EC (BFR): Yes CA Prop 65 (CJ for Wire & Cable): Yes MII Order #39 (China RoHS): Yes Telecommunications Standards: Category 5e - TIA 568.C.2 Other Specification: NEMA WC-63.1 Category 5e Applicable Patents: Country www.belden.com/p Flame Test UL Flame Test: UL1666 Riser, UL1685 FT4/IEEE 1202 Vertical Tray Flame Test CSA Flame Test: FT4 Suitability Suitability - Indoor: Yes Suitability - Outdoor: No Suitability - Burial: No Sunlight Resistance: No Oil Resistance: No Non-halogenated: No Plenum/Non-Plenum Plenum (Y/N): No Plenum Number: 1213 Electrical Characteristics (Overall) Nom. Mutual Capacitance: Capacitance (pF/ft) 15 Maximum Capacitance Unbalance (pF/100 m): 330 Nominal Velocity of Propagation: VP (%) 70 Maximum Delay: Delay (ns/100 m) 510.000 Max. Delay Skew: Delay Skew (ns/100 m) 25 Maximum Conductor DC Resistance: DCR @ 20°C (Ohm/100 m) 8.900 Max. Operating Voltage - UL: Voltage 300 V RMS Maximum DCR Unbalanced: DCR Unbalance @ 20°C (%) 3 Electrical Characteristics-Premise (Overall) Premise Cable Electrical Table 1: Freq. (MHz) Max. Attenuation (dB/100 m) Min. NEXT (dB) Min. PSNEXT (dB) Min. ACR (dB) Min. PSACR (dB) Min RL (dB) Page 2 of 4 02-01-2017 Detailed Specifications & Technical Data ENGLISH MEASUREMENT VERSION 1212 Multi-Conductor - Enhanced Category 5E Nonbonded-Pair Cable 1 2.000 70.3 69.3 68.3 67.3 20.000 4 4.000 61.3 60.3 57.3 56.3 23.000 8 5.700 56.8 55.8 51.1 50.1 24.500 10 6.400 55.3 54.3 48.9 47.9 25.000 16 8.100 52.2 51.2 44.1 43.1 25.000 20 9.100 50.8 49.8 41.7 40.7 25.000 25 10.200 49.3 48.3 39.1 38.1 24.300 31.25 11.400 47.9 46.9 36.4 35.4 23.600 62.5 16.400 43.4 42.4 27.0 26.0 21.500 100 21.000 40.3 39.3 19.3 18.3 20.100 155 26.600 37.4 36.4 10.9 9.9 18.800 200 30.500 35.8 34.8 5.3 4.3 18.000 250 34.400 34.3 33.3 -0.1 -1.1 17.300 300 38.000 33.1 32.1 14.400 350 41.400 32.1 31.1 13.800 400 44.600 31.3 30.3 13.300 450 47.700 30.5 29.5 12.800 Premise Cable Electrical Table 2: Freq. (MHz) Input (Unfitted) Imp. (Ohms) Fitted Impedance Min. ACRF (dB) Min. PSACRF (dB) 1 100 ± 15 100 ± 15 67.8 65.8 4 100 ± 15 100 ± 15 55.8 53.8 8 100 ± 15 100 ± 15 49.7 47.7 10 100 ± 15 100 ± 15 47.8 45.8 16 100 ± 15 100 ± 15 43.7 41.7 20 100 ± 15 100 ± 15 41.8 39.8 25 100 ± 15 100 ± 15 39.8 37.8 31.25 100 ± 15 100 ± 15 37.9 35.9 62.5 100 ± 15 100 ± 15 31.9 29.9 100 100 ± 15 100 ± 15 27.8 25.8 155 100 ± 22 100 ± 15 24.0 22.0 200 100 ± 22 100 ± 15 21.8 19.8 250 100 ± 32 100 ± 15 19.8 17.8 300 100 ± 32 100 ± 15 18.3 16.3 350 100 ± 32 100 ± 15 16.9 14.9 400 100 ± 32 100 ± 15 15.8 13.8 450 100 ± 32 100 ± 15 14.7 12.7 Notes (Overall) Notes: Jacket sequentially marked at 2 ft./1m intervals. Third party verified to ANSI/TIA-568-C.2, Category 5e. Values above 350 MHz are for Engineering Information Only. Reference (Overall) Previous Part Number: 24570179, 24596505, 24570464, 24570464+HU, 24596805, 24570469, 24570161, 24570161+HU, 24570186, 24570186+HU, 24570460, 24570166, 24570166+HU, 24570181 Put Ups and Colors: Item # Putup Ship Weight Color 1212 003U1000 1,000 FT 21.000 LB ORANGE Notes Item Desc 1212 004U1000 1,000 FT 21.000 LB YELLOW 1212 0041000 1,000 FT 23.000 LB YELLOW 1212 005U1000 1,000 FT 21.000 LB GREEN, DARK 1212 006U1000 1,000 FT 21.000 LB BLUE, LIGHT 1212 0061000 1,000 FT 23.000 LB BLUE, LIGHT 1212 0062500 2,500 FT 52.500 LB BLUE, LIGHT CAT5E+ 4PR U/UTP CMR REEL 1212 008U1000 1,000 FT 21.000 LB GRAY CAT5E+ 4PR U/UTP CMR BOX 1212 009U1000 1,000 FT 21.000 LB WHITE CAT5E+ 4PR U/UTP CMR BOX 1212 0091000 1,000 FT 23.000 LB WHITE CAT5E+ 4PR U/UTP CMR REEL 1212 010U1000 1,000 FT 21.000 LB BLACK CAT5E+ 4PR U/UTP CMR BOX CAT5E+ 4PR U/UTP CMR BOX CAT5E+ 4PR U/UTP CMR BOX C CAT5E+ 4PR U/UTP CMR REEL CAT5E+ 4PR U/UTP CMR BOX CAT5E+ 4PR U/UTP CMR BOX C CAT5E+ 4PR U/UTP CMR REEL Notes: C = CRATE REEL PUT-UP. Revision Number: 8 Revision Date: 06-09-2016 © 2017 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether Page 3 of 4 02-01-2017 Detailed Specifications & Technical Data ENGLISH MEASUREMENT VERSION 1212 Multi-Conductor - Enhanced Category 5E Nonbonded-Pair Cable in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale. Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the compliance date may be in stock at Belden facilities and in our Distributor’s inventory. The information provided in this Product Disclosure, and the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Belden’s knowledge, information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product. Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 2014/35/EU). Page 4 of 4 02-01-2017
1212 005U1000 价格&库存

很抱歉,暂时无法提供与“1212 005U1000”相匹配的价格&库存,您可以联系我们找货

免费人工找货