Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
1266A Multi-Conductor - Single-Pair Cable
For more Information
please call
1-800-Belden1
General Description:
22 AWG stranded (7x30) TC conductors, polypropylene insulation, twisted pair, overall Beldfoil shield
(100% coverage), 24 AWG stranded TC drain wire, PVC jacket.
Physical Characteristics (Overall)
Conductor
AWG:
# Pairs AWG Stranding Conductor Material
1
22
7x30
TC - Tinned Copper
Total Number of Conductors:
2
Insulation
Insulation Material:
Insulation Material Wall Thickness (in.)
PP - Polypropylene .010
Outer Shield
Outer Shield Material:
Outer Shield Trade Name Type Outer Shield Material
Beldfoil®
Coverage (%)
Tape Aluminum Foil-Polyester Tape 100
Outer Shield Drain Wire AWG:
AWG Stranding Drain Wire Conductor Material
24
7x32
TC - Tinned Copper
Outer Jacket
Outer Jacket Material:
Outer Jacket Material
Nom. Wall Thickness (in.)
PVC - Polyvinyl Chloride .020
Overall Cable
Overall Nominal Diameter:
0.143 in.
Pair
Pair Color Code Chart:
Number Color
1
Black & Red
Mechanical Characteristics (Overall)
Operating Temperature Range:
-20°C To +60°C
UL Temperature Rating:
60°C
Bulk Cable Weight:
14 lbs/1000 ft.
Max. Recommended Pulling Tension:
25 lbs.
Min. Bend Radius/Minor Axis:
1.500 in.
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
NEC/(UL) Specification:
CM
CEC/C(UL) Specification:
CM
EU Directive 2011/65/EU (ROHS II):
Yes
EU CE Mark:
Yes
EU Directive 2000/53/EC (ELV):
Yes
EU Directive 2002/95/EC (RoHS):
Yes
EU RoHS Compliance Date (mm/dd/yyyy):
01/01/2004
EU Directive 2002/96/EC (WEEE):
Yes
Page 1 of 3
01-05-2017
Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
1266A Multi-Conductor - Single-Pair Cable
EU Directive 2003/11/EC (BFR):
Yes
CA Prop 65 (CJ for Wire & Cable):
Yes
MII Order #39 (China RoHS):
Yes
Flame Test
UL Flame Test:
UL1685 UL Loading
Plenum/Non-Plenum
Plenum (Y/N):
No
Electrical Characteristics (Overall)
Nom. Characteristic Impedance:
Impedance (Ohm)
55
Nom. Inductance:
Inductance (µH/ft)
.18
Nom. Capacitance Conductor to Conductor:
Capacitance (pF/ft)
30
Nom. Capacitance Cond. to Other Conductor & Shield:
Capacitance (pF/ft)
54
Nominal Velocity of Propagation:
VP (%)
66
Nominal Delay:
Delay (ns/ft)
1.5
Nom. Conductor DC Resistance:
DCR @ 20°C (Ohm/1000 ft)
15
Nominal Outer Shield DC Resistance:
DCR @ 20°C (Ohm/1000 ft)
18
Max. Operating Voltage - UL:
Voltage
300 V RMS
Max. Recommended Current:
Current
2.3 Amps per conductor @ 25°C
Notes (Overall)
Notes: Unique design features lower capacitance and greater flexibility than standard audio pair constructions.
Put Ups and Colors:
Item #
Putup
Ship Weight
Color
1266A 001U1000
1,000 FT
15.000 LB
BROWN
Notes
Item Desc
2 #22 PP FS PVC
1266A 002U1000
1,000 FT
15.000 LB
RED
2 #22 PP FS PVC
1266A 003U1000
1,000 FT
15.000 LB
ORANGE
2 #22 PP FS PVC
1266A 004U1000
1,000 FT
15.000 LB
YELLOW
2 #22 PP FS PVC
1266A 005U1000
1,000 FT
15.000 LB
GREEN, DARK
2 #22 PP FS PVC
1266A 006U1000
1,000 FT
15.000 LB
BLUE, LIGHT
2 #22 PP FS PVC
1266A 007U1000
1,000 FT
15.000 LB
VIOLET
2 #22 PP FS PVC
1266A 008U1000
1,000 FT
15.000 LB
GRAY
2 #22 PP FS PVC
1266A 009U1000
1,000 FT
15.000 LB
WHITE
2 #22 PP FS PVC
1266A 010U1000
1,000 FT
15.000 LB
BLACK
1266A 0101000
1,000 FT
15.000 LB
BLACK
2 #22 PP FS PVC
C
2 #22 PP FS PVC
Notes:
C = CRATE REEL PUT-UP.
Page 2 of 3
01-05-2017
Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
1266A Multi-Conductor - Single-Pair Cable
Revision Number: 1
Revision Date: 08-10-2012
© 2017 Belden, Inc
All Rights Reserved.
Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to
change without notice, and the listing of such information and specifications does not ensure product availability.
Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for
any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether
in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein.
All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the compliance date may be in stock at Belden facilities
and in our Distributor’s inventory. The information provided in this Product Disclosure, and the identification of materials listed as reportable or restricted within the Product Disclosure, is
correct to the best of Belden’s knowledge, information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide for the
safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not to be considered a warranty or quality specification.
Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the
product.
Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 2014/35/EU).
Page 3 of 3
01-05-2017
很抱歉,暂时无法提供与“1266A 007U1000”相匹配的价格&库存,您可以联系我们找货
免费人工找货