0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
3612 010A1000

3612 010A1000

  • 厂商:

    BELDEN

  • 封装:

  • 描述:

    CAT6E 4PR U/UTP CMR RIB BLACK

  • 数据手册
  • 价格&库存
3612 010A1000 数据手册
Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 3612 Multi-Conductor - Enhanced Category 6 Nonbonded-Pair Cable For more Information please call 1-800-Belden1 General Description: CAT6+ (400MHz), 4-Pair, U/UTP-Unshielded, Riser-CMR, Premise Horizontal Cable, 23 AWG Solid Bare Copper Conductors, Polyolefin Insulation, Patented X-Spline, Ripcord, PVC jacket Usage (Overall) Suitable Applications: Premise Horizontal Cable, Gigabit Ethernet, 100BaseTX, 100BaseVG ANYLAN, 155ATM, 622ATM, NTSC/PAL Component or Composite Video, AES/EBU Digital Audio, AES51, RS-422, Noisy Environments Physical Characteristics (Overall) Conductor AWG: # Pairs AWG Stranding Conductor Material 4 23 Solid BC - Bare Copper Total Number of Conductors: 8 Insulation Insulation Material: Insulation Material Polyolefin Outer Shield Outer Shield Material: Outer Shield Material Unshielded Outer Jacket Outer Jacket Material: Outer Jacket Material Nom. Wall Thickness (mm) PVC 0.432 Outer Jacket Diameter: Nom. Dia. (mm) 5.969 Outer Jacket Ripcord: Yes Overall Cable Overall Cabling Separator Material: Patented X-Spline Center Member Overall Nominal Diameter: 5.969 mm Pair Pair Color Code Chart: Number Color 1 White/Blue Stripe & Blue 2 White/Orange Stripe & Orange 3 White/Green Stripe & Green 4 White/Brown Stripe & Brown Mechanical Characteristics (Overall) Storage Temperature Range: -30°C To +75°C Page 1 of 5 01-10-2014 Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 3612 Multi-Conductor - Enhanced Category 6 Nonbonded-Pair Cable Installation Temperature Range: +5°C To +50°C Operating Temperature Range: 0°C To +75°C UL Temperature Rating: 75°C Bulk Cable Weight: 41.670 Kg/Km Max. Recommended Pulling Tension: 200.169 N Min. Bend Radius/Minor Axis: 19.050 mm Min. Bend/Installation: 57.150 mm Applicable Specifications and Agency Compliance (Overall) Applicable Standards & Environmental Programs NEC/(UL) Specification: CMR CEC/C(UL) Specification: CMR EU Directive 2011/65/EU (ROHS II): Yes Other Standards: ISO/IEC 11801 ed 2.1 (2008) Class E EU CE Mark: Yes EU Directive 2000/53/EC (ELV): Yes EU Directive 2002/95/EC (RoHS): Yes EU RoHS Compliance Date (mm/dd/yyyy): 04/03/2009 EU Directive 2002/96/EC (WEEE): Yes EU Directive 2003/11/EC (BFR): Yes CA Prop 65 (CJ for Wire & Cable): Yes MII Order #39 (China RoHS): Yes Telecommunications Standards: Category 6 - TIA 568.C.2 Applicable Patents: Country Patent US 6074503 US 7663061 US 7977575 US 8563455 Flame Test UL Flame Test: UL1666 Vertical Riser C(UL) Flame Test: FT4 Suitability Suitability - Indoor: Yes Suitability - Outdoor: No Suitability - Aerial: No Suitability - Burial: No Sunlight Resistance: No Plenum/Non-Plenum Plenum (Y/N): No Plenum Number: 3613 Electrical Characteristics (Overall) Nom. Mutual Capacitance: Capacitance (pF/m) 50.8555 Page 2 of 5 01-10-2014 Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 3612 Multi-Conductor - Enhanced Category 6 Nonbonded-Pair Cable Maximum Capacitance Unbalance (pF/100 m): 330 Nominal Velocity of Propagation: VP (%) 70.000 Maximum Delay: Freq. (MHz) Delay (ns/100 m) 100.000 537.600 Typical Delay Skew: Delay Skew (ns/m) 114.835 Maximum Conductor DC Resistance: DCR @ 20°C (Ohm/100 m) 7.700 Max. Operating Voltage - UL: Voltage 300 V RMS Maximum DCR Unbalanced: DCR Unbalance @ 20°C (%) 3.000 Electrical Characteristics-Premise (Overall) Premise Cable Electrical Table 1: Freq. (MHz) Max. Attenuation (dB/100 m) Min. NEXT (dB) Min. PSNEXT (dB) Min. ACR (dB) Min. PSACR (dB) Min RL (dB) 0.772 1.800 81.0 81.0 79.2 79.2 1 2.000 79.3 79.3 77.3 77.3 20.000 4 3.700 70.3 70.3 66.6 66.6 23.000 8 5.200 65.8 65.8 60.6 60.6 24.500 10 5.800 64.3 64.3 58.5 58.5 25.000 16 7.400 61.2 61.2 53.9 53.9 25.000 20 8.300 59.8 59.8 51.5 51.5 25.000 25 9.300 58.3 58.3 49.1 49.1 24.300 31.25 10.400 56.9 56.9 46.5 46.5 23.600 62.5 15.000 52.4 52.4 37.4 37.4 21.500 100 19.300 49.3 49.3 30.0 30.0 20.800 155 24.600 46.5 46.5 21.8 21.8 19.500 200 28.300 44.8 44.8 16.5 16.5 18.700 250 32.100 43.3 43.3 11.2 11.2 18.000 300 35.600 42.1 42.1 6.5 6.5 17.500 350 38.900 41.1 40.1 2.3 2.3 17.000 400 42.000 38.3 38.3 -3.7 -3.7 16.600 450 45.000 37.5 37.5 16.200 500 47.900 36.8 36.8 15.900 550 50.600 36.2 36.2 15.600 600 53.300 35.6 35.6 15.400 650 55.900 35.1 35.1 15.100 Premise Cable Electrical Table 2: Freq. (MHz) Input (Unfitted) Imp. (Ohms) Min. ACRF (dB) Min. PSACRF (dB) .772 75.0 73.0 1 100 ± 15 72.8 70.8 4 100 ± 15 60.8 58.8 8 100 ± 15 54.7 52.7 10 100 ± 15 52.8 50.8 16 100 ± 15 48.7 46.7 20 100 ± 15 46.8 44.8 25 100 ± 15 44.8 42.8 31.25 100 ± 15 42.9 40.9 Page 3 of 5 01-10-2014 Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 3612 Multi-Conductor - Enhanced Category 6 Nonbonded-Pair Cable 62.5 100 ± 15 36.9 34.9 100 100 ± 15 32.8 30.8 155 100 ± 22 28.9 26.9 200 100 ± 22 26.8 24.8 250 100 ± 32 24.8 22.8 300 100 ± 32 23.3 21.3 350 100 ± 32 21.9 19.9 400 100 ± 32 20.8 18.8 450 100 ± 32 19.7 17.7 500 100 ± 32 18.8 16.8 550 100 ± 32 18.0 16.0 600 100 ± 32 17.2 15.2 650 100 ± 32 16.5 14.5 Premise Cable Electrical Table 4: Frequency (MHz) Min. TCL (dB) Min. ELTCTL (dB) 0.772 40.000 37.200 1.000 40.000 35.000 4.000 40.000 23.000 8.000 40.000 16.900 10.000 40.000 15.000 16.000 38.000 10.900 20.000 37.000 9.000 25.000 36.000 7.000 31.250 35.100 62.500 32.000 100.000 30.000 155.000 28.100 200.000 27.000 250.000 26.000 Notes (Overall) Notes: Jacket sequentially marked at 2 ft/1m. intervals. Third party verified to ANSI/TIA-568-C.2 Category 6. Values above 400 MHz are for engineering information only. Put Ups and Colors: Item # Putup Ship Weight Color Notes Item Desc 3612 003A1000 305 MT 13.154 KG ORANGE C CAT6E 4PR U/UTP CMR RIB 3612 003U1000 305 MT 12.247 KG ORANGE 3612 004A1000 305 MT 13.154 KG YELLOW 3612 004U1000 305 MT 12.247 KG YELLOW 3612 0041000 305 MT 12.247 KG YELLOW 3612 0042500 762 MT 30.618 KG YELLOW 3612 005A1000 305 MT 13.154 KG GREEN, DARK 3612 005U1000 305 MT 12.247 KG GREEN, DARK 3612 0051000 305 MT 12.247 KG GREEN, DARK C CAT6E 4PR U/UTP CMR REEL 3612 006A1000 305 MT 13.154 KG BLUE, LIGHT C CAT6E 4PR U/UTP CMR RIB 3612 006U1000 305 MT 12.247 KG BLUE, LIGHT 3612 0061000 305 MT 12.247 KG BLUE, LIGHT 3612 0062500 762 MT 30.618 KG BLUE, LIGHT 3612 007A1000 305 MT 13.154 KG VIOLET 3612 007U1000 305 MT 12.247 KG VIOLET 3612 008A1000 305 MT 13.154 KG GRAY 3612 008U1000 305 MT 12.247 KG GRAY 3612 0081000 305 MT 12.247 KG GRAY C CAT6E 4PR U/UTP CMR REEL 3612 009A1000 305 MT 13.154 KG WHITE C CAT6E 4PR U/UTP CMR RIB 3612 009U1000 305 MT 12.247 KG WHITE 3612 0091000 305 MT 12.247 KG WHITE 3612 0092500 762 MT 30.618 KG WHITE 3612 010A1000 305 MT 13.154 KG BLACK CAT6E 4PR U/UTP CMR BOX C CAT6E 4PR U/UTP CMR RIB CAT6E 4PR U/UTP CMR BOX C CAT6E 4PR U/UTP CMR REEL CAT6E 4PR U/UTP CMR REEL C CAT6E 4PR U/UTP CMR RIB CAT6E 4PR U/UTP CMR BOX CAT6E 4PR U/UTP CMR BOX C CAT6E 4PR U/UTP CMR REEL CAT6E 4PR U/UTP CMR REEL C CAT6E 4PR U/UTP CMR RIB CAT6E 4PR U/UTP CMR BOX C CAT6E 4PR U/UTP CMR RIB CAT6E 4PR U/UTP CMR BOX CAT6E 4PR U/UTP CMR BOX C CAT6E 4PR U/UTP CMR REEL CAT6E 4PR U/UTP CMR REEL C Page 4 of 5 CAT6E 4PR U/UTP CMR RIB 01-10-2014 Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 3612 Multi-Conductor - Enhanced Category 6 Nonbonded-Pair Cable 3612 010U1000 305 MT 12.247 KG BLACK 3612 0101000 305 MT 12.247 KG BLACK CAT6E 4PR U/UTP CMR BOX C CAT6E 4PR U/UTP CMR REEL Notes: C = CRATE REEL PUT-UP. Revision Number: 11 Revision Date: 01-08-2014 © 2014 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale. Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the compliance date may be in stock at Belden facilities and in our Distributor’s inventory. The information provided in this Product Disclosure, and the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Belden’s knowledge, information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product. Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 73/23/EEC), as amended by directive 93/68/EEC. Page 5 of 5 01-10-2014
3612 010A1000 价格&库存

很抱歉,暂时无法提供与“3612 010A1000”相匹配的价格&库存,您可以联系我们找货

免费人工找货