Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
7910A Composite - Composite Data, Audio, Video, Security and Control Cable
For more Information
please call
1-800-Belden1
General Description:
Composite - (1) Cat 5e 4-bonded-pair 24 AWG unshielded plus (1) Series 6 Coax with Duobond Plus®
Bonded Tri-shield, polyolefin insulation on the pairs; Gas-injected FPE insulation on the coax, F-R PVC
jackets, overall F-R PVC jacket.
Usage (Overall)
Suitable Applications:
HDTV, DBS, CATV, CCTV, Multimedia, Voice, Video, Data, High Speed Internet, Networked Computing,
Distributed Video, Distributed Audio, Security Monitoring, Energy Monitoring
Coax
Physical Characteristics
Conductor
AWG:
# Coax AWG Stranding Conductor Material Dia. (in.)
1
18
Solid
BC - Bare Copper
0.040
Insulation
Insulation Material:
Insulation Material
Dia. (in.)
Gas-injected FPE - Foam Polyethylene 0.180
Inner Shield
Inner Shield Material:
Layer # Inner Shield Trade Name Type Inner Shield Material
% Coverage (%)
1
Tape Bonded Aluminum Foil-Polyester Tape-Aluminum Foil
100
2
Braid AL - Aluminum
77
3
Tape Bonded Aluminum Foil-Polyester Tape w/Shorting Fold 100
Bonded Duofoil®
Inner Jacket
Inner Jacket Material:
Inner Jacket Material
Nom. Dia. (in.)
PVC - Polyvinyl Chloride 0.275
Outer Jacket
Outer Jacket Color Code Chart:
Color
Black
Overall Diameter
Overall Nominal Diameter:
0.275 in.
Electrical Characteristics
Nom. Characteristic Impedance:
Impedance (Ohm)
75
Nom. Inductance:
Inductance (µH/ft)
0.097
Nom. Capacitance Conductor to Shield:
Capacitance (pF/ft)
16.200
Nominal Velocity of Propagation:
VP (%)
83.000
Nominal Delay:
Delay (ns/ft)
1.200
Nom. Conductor DC Resistance:
DCR @ 20°C (Ohm/1000 ft)
Page 1 of 4
01-09-2015
Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
7910A Composite - Composite Data, Audio, Video, Security and Control Cable
6.400
Nom. Inner Shield DC Resistance:
DCR @ 20°C (Ohm/1000 ft)
4.600
Minimum Structural Return Loss:
Start Freq. (MHz) Stop Freq. (MHz) Min. SRL (dB)
5.000
1000.000
20.000
1000.000
2250.000
15.000
2250.000
3000.000
10.000
Nom. Attenuation:
Freq. (MHz) Attenuation (dB/100 ft.)
5.000
0.500
55.000
1.400
211.000
2.600
500.000
4.100
750.000
5.100
862.000
5.500
1000.000
6.000
1450.000
7.800
1800.000
8.600
2250.000
9.800
3000.000
11.300
Max. Attenuation:
Freq. (MHz) Attenuation (dB/100 ft.)
5.000
0.670
55.000
1.600
211.000
2.870
500.000
4.480
750.000
5.590
862.000
5.980
1000.000
6.540
1450.000
8.000
1800.000
8.800
2250.000
10.000
3000.000
11.900
Max. Operating Voltage - UL:
350 V RMS
Shield Effectiveness:
Start Frequency (MHz) Stop Frequency (MHz) Shield Effectiveness (dB)
5.000
50.000
105.000
50.000
1000.000
125.000
Twisted Pair
Physical Characteristics
Conductor
AWG:
# Pairs AWG Stranding Conductor Material Dia. (in.)
4
24
Solid
BC - Bare Copper
0.020
Insulation
Insulation Material:
Insulation Material Dia. (in.)
PO - Polyolefin
0.035
Twisted Pair Color Code Chart:
Number Color
1
White/Blue Stripe and Blue
2
White/Orange Stripe and Orange
3
White/Green Stripe and Green
4
White/Brown Stripe and Brown
Outer Jacket
Outer Jacket Material:
Outer Jacket Material
PVC - Polyvinyl Chloride
Outer Jacket Color Code Chart:
Color
Blue
Page 2 of 4
01-09-2015
Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
7910A Composite - Composite Data, Audio, Video, Security and Control Cable
Overall Diameter
Overall Nominal Diameter:
0.200 in.
Electrical Characteristics
Nom. Mutual Capacitance:
Capacitance (pF/ft)
15.000
Nominal Velocity of Propagation:
VP (%)
70.000
Nom. Conductor DC Resistance:
DCR @ 20°C (Ohm/1000 ft)
9.380
Max. Operating Voltage - UL:
Voltage
300 V RMS
Other Electrical Characteristic 1:
Third party verified to TIA/EIA-568-B.2, Category 5e.
Premise Cable Electrical Table 1:
Freq. (MHz) Max. Attenuation (dB/100 m) Min. PSNEXT (dB) Min. PSACR (dB) Min RL (dB)
1.0
2.000
62.3
60
20.000
4.0
4.100
53.3
49
23.000
8.0
5.800
48.8
43
24.500
10.0
6.500
47.3
41
25.000
16.0
8.200
44.3
36
25.000
20.0
9.300
42.8
34
25.000
25.0
10.400
41.3
31
24.300
31.25
11.700
39.9
28
23.600
62.5
17.000
35.4
19
21.500
100
22.000
32.3
11
20.100
Premise Cable Electrical Table 2:
Freq. (MHz) Input (Unfitted) Imp. (Ohms) Min. PSELFEXT (dB)
1.0
100 +/- 15%
60.8
4.0
100 +/- 15%
48.7
8.0
100 +/- 15%
42.7
10.0
100 +/- 15%
40.8
16.0
100 +/- 15%
36.7
20.0
100 +/- 15%
34.7
25.0
100 +/- 15%
32.8
31.25
100 +/- 15%
30.9
62.5
100 +/- 15%
24.8
100
100 +/- 15%
20.8
Physical Characteristics (Overall)
Outer Shield
Outer Shield Material:
Outer Shield Material
Unshielded
Outer Jacket
Outer Jacket Material:
Outer Jacket Material
F-R PVC - flame Retardant Polyvinyl Chloride
Outer Jacket Ripcord:
Yes
Overall Cable
Overall Nominal Diameter:
0.335 in.
Mechanical Characteristics (Overall)
Operating Temperature Range:
-20°C To +75°C
Bulk Cable Weight:
78.000 lbs/1000 ft.
Max. Recommended Pulling Tension:
131.000 lbs.
Min. Bend Radius/Minor Axis:
3.500 in.
Page 3 of 4
01-09-2015
Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
7910A Composite - Composite Data, Audio, Video, Security and Control Cable
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
NEC/(UL) Specification:
CMR
CEC/C(UL) Specification:
CMG
EU Directive 2011/65/EU (ROHS II):
Yes
Other Standards:
ISO/IE 11801, Category 5
EU CE Mark:
Yes
EU Directive 2000/53/EC (ELV):
Yes
EU Directive 2002/95/EC (RoHS):
Yes
EU RoHS Compliance Date (mm/dd/yyyy):
01/01/2004
EU Directive 2002/96/EC (WEEE):
Yes
EU Directive 2003/11/EC (BFR):
Yes
CA Prop 65 (CJ for Wire & Cable):
Yes
MII Order #39 (China RoHS):
Yes
Telecommunications Standards:
ANSI/TIA/EIA-568-B.2, Category 5e
Other Specification:
NEMA WC-63.1, Category 5e
Flame Test
UL Flame Test:
UL1666 Riser
C(UL) Flame Test:
FT4
Plenum/Non-Plenum
Plenum (Y/N):
No
Notes (Overall)
Notes: Overall jacket sequentially marked.
Put Ups and Colors:
Item #
Revision Number: 0
Putup
Ship Weight
Color
Notes
Item Desc
Revision Date: 04-24-2008
© 2015 Belden, Inc
All Rights Reserved.
Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to
change without notice, and the listing of such information and specifications does not ensure product availability.
Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for
any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether
in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein.
All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the compliance date may be in stock at Belden facilities
and in our Distributor’s inventory. The information provided in this Product Disclosure, and the identification of materials listed as reportable or restricted within the Product Disclosure, is
correct to the best of Belden’s knowledge, information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide for the
safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not to be considered a warranty or quality specification.
Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the
product.
Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 73/23/EEC), as amended by directive 93/68/EEC.
Page 4 of 4
01-09-2015