Technical Data Sheet – Unshielded (YY) PVC Control Cable
MachFlex 350 YY
VDE Registered
Flexible PVC Control Cables
Applications
Designed for applications which are installed in occasional flexing and fixed locations. Cable applications
include precision control sensors, multi axis control machines, temperature controllers, control panels,
machine cutting tools, auxiliary equipment, motor speed control, production machinery and many more.
General Reference Standards
DIN VDE 0295, IEC 60228, BS 6360
DIN EN 50290‐2‐22, DIN VDE 0207‐363‐4‐1
IEC 60227‐5, EN 50525‐2‐51, VDE 0281‐13
DIN VDE 0482‐332‐1‐2, DIN EN 60332‐1‐2, IEC 60332‐1‐2
RoHS, REACH & CE Directives
Construction & Performance
1.
Conductor Material
Stranded bare copper (DIN VDE 0295 Class 5 / IEC 60228 class 5)
2.
Insulation Material & Colour
PVC (polyvinyl chloride), DIN VDE 0293‐1 (colour)
A) All black colour with number coding = without protective earth
conductor. OR
B) Black colour with number coding and 1 green & yellow colour conductor
= with protective earth conductor.
3.
Jacket / Sheath Material
PVC (polyvinyl chloride)
4.
Flame Retardancy
VDE 0482‐332‐1‐2, DIN EN 60332‐1‐2, IEC 60332‐1‐2
5.
Voltage Rating (Uo/U)
300 / 500 V
6.
Oil Resistant
DIN EN 50290‐2‐22 (TM54)
7.
Temperature Range
‐30°C TO +70°C (Occasional movement)
‐40°C TO +80°C (Fixed installation)
8.
Bending Radius
10 x OD (Occasional movement)
4 x OD (Fixed installation)
9.
Other Properties
Good UV resistance, chemical resistance & flexibility
1
© 2014 Belden, Inc
All Rights Reserved.
Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to change without notice, and the listing of such information and
specifications does not ensure product availability. Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages
(including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in
connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Technical Data Sheet – Unshielded (YY) PVC Control Cable
TABLE A
Part Code
2X0.5
3X0.5
3G0.5
4X0.5
4G0.5
5X0.5
5G0.5
7X0.5
7G0.5
9X0.5
9G0.5
10X0.5
10G0.5
12X0.5
12G0.5
14X0.5
14G0.5
16X0.5
16G0.5
18X0.5
18G0.5
20X0.5
20G0.5
2X0.75
3X0.75
3G0.75
4X0.75
4G0.75
5X0.75
5G0.75
7X0.75
7G0.75
9X0.75
9G0.75
10X0.75
10G0.75
12X0.75
12G0.75
14X0.75
14G0.75
16X0.75
16G0.75
18X0.75
18G0.75
20X0.75
20G0.75
Cable
Description
2 X0.5
3 X0.5
3 G0.5
4 X0.5
4 G0.5
5 X0.5
5 G0.5
7 X0.5
7 G0.5
9 X0.5
9 G0.5
10 X0.5
10 G0.5
12 X0.5
12 G0.5
14 X0.5
14 G0.5
16 X0.5
16 G0.5
18 X0.5
18 G0.5
20 X0.5
20 G0.5
2 X0.75
3 X0.75
3 G0.75
4 X0.75
4 G0.75
5 X0.75
5 G0.75
7 X0.75
7 G0.75
9 X0.75
9 G0.75
10 X0.75
10 G0.75
12 X0.75
12 G0.75
14 X0.75
14 G0.75
16 X0.75
16 G0.75
18 X0.75
18 G0.75
20 X0.75
20 G0.75
No. Of
Cores
2
3
3
4
4
5
5
7
7
9
9
10
10
12
12
14
14
16
16
18
18
20
20
2
3
3
4
4
5
5
7
7
9
9
10
10
12
12
14
14
16
16
18
18
20
20
Nom. Conductor
Size (mm²)
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
Nom. Cable
Diameter (mm)
4.6
4.9
4.9
5.3
5.3
5.9
5.9
6.4
6.4
7.9
7.9
8.3
8.3
8.6
8.6
9.1
9.1
9.6
9.6
10.2
10.2
10.8
10.8
5.0
5.4
5.4
5.9
5.9
6.5
6.5
7.2
7.2
8.9
8.9
9.3
9.3
9.6
9.6
10.2
10.2
10.8
10.8
11.4
11.4
12.1
12.1
Nom. Cable Weight
(kg/km)
28
35
35
44
44
53
53
68
68
90
90
100
100
114
114
131
131
148
148
167
167
186
186
36
46
46
58
58
70
70
91
91
120
120
134
134
154
154
176
176
199
199
225
225
251
251
2
© 2014 Belden, Inc
All Rights Reserved.
Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to change without notice, and the listing of such information and
specifications does not ensure product availability. Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages
(including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in
connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Technical Data Sheet – Unshielded (YY) PVC Control Cable
Part Code
2X1.0
3X1.0
3G1.0
4X1.0
4G1.0
5X1.0
5G1.0
7X1.0
7G1.0
9X1.0
9G1.0
10X1.0
10G1.0
12X1.0
12G1.0
14X1.0
14G1.0
16X1.0
16G1.0
18X1.0
18G1.0
20X1.0
20G1.0
2X1.5
3X1.5
3G1.5
4X1.5
4G1.5
5X1.5
5G1.5
7X1.5
7G1.5
9X1.5
9G1.5
10X1.5
10G1.5
12X1.5
12G1.5
14X1.5
14G1.5
16X1.5
16G1.5
18X1.5
18G1.5
20X1.5
20G1.5
2X2.5
Cable
Description
2 X1.0
3 X1.0
3 G1.0
4 X1.0
4 G1.0
5 X1.0
5 G1.0
7 X1.0
7 G1.0
9 X1.0
9 G1.0
10 X1.0
10 G1.0
12 X1.0
12 G1.0
14 X1.0
14 G1.0
16 X1.0
16 G1.0
18 X1.0
18 G1.0
20 X1.0
20 G1.0
2 X1.5
3 X1.5
3 G1.5
4 X1.5
4 G1.5
5 X1.5
5 G1.5
7 X1.5
7 G1.5
9 X1.5
9 G1.5
10 X1.5
10 G1.5
12 X1.5
12 G1.5
14 X1.5
14 G1.5
16 X1.5
16 G1.5
18 X1.5
18 G1.5
20 X1.5
20 G1.5
2 X2.5
No. Of
Cores
2
3
3
4
4
5
5
7
7
9
9
10
10
12
12
14
14
16
16
18
18
20
20
2
3
3
4
4
5
5
7
7
9
9
10
10
12
12
14
14
16
16
18
18
20
20
2
Nom. Conductor
Size (mm²)
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.5
Nom. Cable
Diameter (mm)
5.4
5.8
5.8
6.4
6.4
7.1
7.1
7.8
7.8
9.6
9.6
10.1
10.1
10.5
10.5
11.0
11.0
11.7
11.7
12.4
12.4
13.2
13.2
6.0
6.4
6.4
7.0
7.0
7.8
7.8
8.5
8.5
10.6
10.6
11.1
11.1
11.5
11.5
12.2
12.2
12.9
12.9
13.7
13.7
14.5
14.5
7.7
Nom. Cable Weight
(kg/km)
44
57
57
72
72
89
89
115
115
151
151
169
169
195
195
224
224
255
255
287
287
319
319
55
71
71
91
91
112
112
145
145
191
191
213
213
247
247
284
284
323
323
364
364
405
405
91
3
© 2014 Belden, Inc
All Rights Reserved.
Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to change without notice, and the listing of such information and
specifications does not ensure product availability. Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages
(including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in
connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Technical Data Sheet – Unshielded (YY) PVC Control Cable
Part Code
3X2.5
3G2.5
4X2.5
4G2.5
5X2.5
5G2.5
7X2.5
7G2.5
9X2.5
9G2.5
10X2.5
10G2.5
12X2.5
12G2.5
14X2.5
14G2.5
16X2.5
16G2.5
18X2.5
18G2.5
20X2.5
20G2.5
2X4
3X4
3G4
4X4
4G4
5X4
5G4
7X4
7G4
9X4
9G4
10X4
10G4
12X4
12G4
2X6
3X6
3G6
4X6
4G6
5X6
5G6
7X6
7G6
9X6
Cable
Description
3 X2.5
3 G2.5
4 X2.5
4 G2.5
5 X2.5
5 G2.5
7 X2.5
7 G2.5
9 X2.5
9 G2.5
10 X2.5
10 G2.5
12 X2.5
12 G2.5
14 X2.5
14 G2.5
16 X2.5
16 G2.5
18 X2.5
18 G2.5
20 X2.5
20 G2.5
2 X4
3 X4
3 G4
4 X4
4 G4
5 X4
5 G4
7 X4
7 G4
9 X4
9 G4
10 X4
10 G4
12 X4
12 G4
2 X6
3 X6
3 G6
4 X6
4 G6
5 X6
5 G6
7 X6
7 G6
9 X6
No. Of
Cores
3
3
4
4
5
5
7
7
9
9
10
10
12
12
14
14
16
16
18
18
20
20
2
3
3
4
4
5
5
7
7
9
9
10
10
12
12
2
3
3
4
4
5
5
7
7
9
Nom. Conductor
Size (mm²)
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6
6
6
6
Nom. Cable
Diameter (mm)
8.3
8.3
9.2
9.2
10.1
10.1
11.2
11.2
13.9
13.9
14.6
14.6
15.2
15.2
16.0
16.0
17.0
17.0
18.1
18.1
19.2
19.2
9.1
9.8
9.8
10.9
10.9
12.0
12.0
13.3
13.3
16.6
16.6
17.5
17.5
18.1
18.1
11.0
11.8
11.8
13.1
13.1
14.5
14.5
16.0
16.0
20.1
Nom. Cable Weight
(kg/km)
118
118
152
152
188
188
244
244
322
322
360
360
417
417
481
481
548
548
618
618
688
688
137
182
182
235
235
292
292
383
383
504
504
564
564
655
655
202
269
269
349
349
434
434
570
570
751
4
© 2014 Belden, Inc
All Rights Reserved.
Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to change without notice, and the listing of such information and
specifications does not ensure product availability. Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages
(including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in
connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Technical Data Sheet – Unshielded (YY) PVC Control Cable
Part Code
9G6
2X10
3X10
3G10
4X10
4G10
5X10
5G10
7X10
7G10
9X10
9G10
2X16
3X16
3G16
4X16
4G16
5X16
5G16
7X16
7G16
2X25
3X25
3G25
4X25
4G25
5X25
5G25
7X25
7G25
2X35
3X35
3G35
4X35
4G35
Cable
Description
9 G6
2 X10
3 X10
3 G10
4 X10
4 G10
5 X10
5 G10
7 X10
7 G10
9 X10
9 G10
2 X16
3 X16
3 G16
4 X16
4 G16
5 X16
5 G16
7 X16
7 G16
2 X25
3 X25
3 G25
4 X25
4 G25
5 X25
5 G25
7 X25
7 G25
2 X35
3 X35
3 G35
4 X35
4 G35
Sheath / Jacket Colour
Colour
1) Grey (RAL 7001)
2) Black
3) Blue
4) Orange
5) Violet
No. Of
Cores
9
2
3
3
4
4
5
5
7
7
9
9
2
3
3
4
4
5
5
7
7
2
3
3
4
4
5
5
7
7
2
3
3
4
4
Nom. Conductor
Size (mm²)
6
10
10
10
10
10
10
10
10
10
10
10
16
16
16
16
16
16
16
16
16
25
25
25
25
25
25
25
25
25
35
35
35
35
35
Nom. Cable
Diameter (mm)
20.1
13.8
14.8
14.8
16.5
16.5
18.3
18.3
20.3
20.3
25.5
25.5
16.8
18.1
18.1
20.2
20.2
22.4
22.4
24.8
24.8
20.8
22.3
22.3
24.9
24.9
27.7
27.7
30.6
30.6
24.0
25.9
25.9
28.9
28.9
Nom. Cable Weight
(kg/km)
751
320
427
427
555
555
692
692
910
910
1198
1198
497
668
668
870
870
1086
1086
1433
1433
770
1038
1038
1354
1354
1693
1693
2229
2229
1013
1365
1365
1780
1780
Colour Code
G8U
010
006
003
007
5
© 2014 Belden, Inc
All Rights Reserved.
Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to change without notice, and the listing of such information and
specifications does not ensure product availability. Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages
(including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in
connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Technical Data Sheet – Unshielded (YY) PVC Control Cable
Packaging
*Belden can offer these cables with various packing options like coiled, plastic or wooden reels. This
will be decided at the discretion of Belden based on the cable design and structure.
Put‐up Length
Putup Length
Putup Length Code
1) 100 Meters*
100M
2) 200 Meters*
200M
3) 300 Meters
300M
*Applicable only for certain part codes, please check with Belden for more information.
Stock Code Selection Procedure:
5
G
2
.
5
G
G
2
.
U
2
Select the sheath /
jacket color code
Select the part code
from Table A
5
8
5
G
0
0
M
Select the putup length
code
8
U
2
0
0
M
Cable Stock Code = 5G2.5 G8U200M
6
© 2014 Belden, Inc
All Rights Reserved.
Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to change without notice, and the listing of such information and
specifications does not ensure product availability. Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages
(including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in
connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale.