0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
9318 0601000

9318 0601000

  • 厂商:

    BELDEN

  • 封装:

  • 描述:

    CBL 1PR 18AWG SHLD

  • 数据手册
  • 价格&库存
9318 0601000 数据手册
Detailed Specifications & Technical Data ENGLISH MEASUREMENT VERSION 9318 Multi-Conductor - 300V Power-Limited Tray Cable For more Information please call 1-800-Belden1 General Description: 18 AWG pairs stranded (19x30) tinned copper conductors, twisted pairs, PVC insulation, overall Beldfoil® shield (100% coverage), PVC jacket. Physical Characteristics (Overall) Conductor AWG: # Pairs AWG Stranding Conductor Material 1 18 19x30 TC - Tinned Copper Total Number of Conductors: 2 Insulation Insulation Material: Insulation Material Wall Thickness (in.) PVC - Polyvinyl Chloride 0.017 Insulation Color Code Chart: Number Color 1 Black & Red Outer Shield Outer Shield Material: Outer Shield Trade Name Type Outer Shield Material Beldfoil® Coverage (%) Tape Aluminum Foil-Polyester Tape 100 Outer Shield Drain Wire AWG: AWG Stranding Drain Wire Conductor Material 20 19x32 TC - Tinned Copper Outer Jacket Outer Jacket Material: Outer Jacket Material Nom. Wall Thickness (in.) PVC - Polyvinyl Chloride .037 Outer Jacket Ripcord: Yes Overall Cable Overall Nominal Diameter: 0.233 in. Mechanical Characteristics (Overall) Operating Temperature Range: -30°C To +105°C UL Temperature Rating: 105°C Bulk Cable Weight: 32 lbs/1000 ft. Max. Recommended Pulling Tension: 26 lbs. Min. Bend Radius/Minor Axis: 2.230 in. Applicable Specifications and Agency Compliance (Overall) Applicable Standards & Environmental Programs NEC/(UL) Specification: CMG, ITC-ER, PLTC-ER CEC/C(UL) Specification: CMG AWM Specification: UL Style 2464 (300 V 80°C) EU Directive 2011/65/EU (ROHS II): Yes EU CE Mark: Yes EU Directive 2000/53/EC (ELV): Yes EU Directive 2002/95/EC (RoHS): Yes EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005 Page 1 of 3 01-05-2017 Detailed Specifications & Technical Data ENGLISH MEASUREMENT VERSION 9318 Multi-Conductor - 300V Power-Limited Tray Cable EU Directive 2002/96/EC (WEEE): Yes EU Directive 2003/11/EC (BFR): Yes CA Prop 65 (CJ for Wire & Cable): Yes MII Order #39 (China RoHS): Yes Flame Test UL Flame Test: UL1685 UL Loading C(UL) Flame Test: FT4 IEEE Flame Test: 1202 Suitability Suitability - Indoor: Yes Suitability - Outdoor: Yes Sunlight Resistance: Yes Plenum/Non-Plenum Plenum (Y/N): No Surface Printing (Overall) Electrical Characteristics (Overall) Nom. Inductance: Inductance (µH/ft) .17 Nom. Capacitance Conductor to Shield: Capacitance (pF/ft) 100 Nom. Capacitance Conductor to Conductor: Capacitance (pF/ft) 54 Nom. Conductor DC Resistance: DCR @ 20°C (Ohm/1000 ft) 5.96 Nominal Outer Shield DC Resistance: DCR @ 20°C (Ohm/1000 ft) 9 Max. Operating Voltage - UL: Voltage Description 300 V RMS PLTC, CMG 150 V RMS ITC Max. Recommended Current: Current 5.5 Amps per conductor @ 25°C Put Ups and Colors: Item # Putup Ship Weight Color 9318 060U1000 1,000 FT 32.000 LB CHROME Notes Item Desc 2 #18 PVC SHLD PVC 9318 060U500 500 FT 17.000 LB CHROME 2 #18 PVC SHLD PVC 9318 0601000 1,000 FT 33.000 LB CHROME 9318 06010000 10,000 FT 330.000 LB CHROME CZ 2 #18 PVC SH PVC 9318 06015000 15,000 FT 645.000 LB CHROME CY 2 #18 PVC SHLD PVC 9318 0605000 5,000 FT 165.000 LB CHROME CZ 2 #18 PVC SHLD PVC 2 #18 PVC FS PVC Notes: C = CRATE REEL PUT-UP. Y = FINAL PUT-UP LENGTH MAY VARY -10% TO +20% FROM LENGTH SHOWN.MAY CONTAIN 2 PIECES. MINIMUM LENGTH OF ANY ONE PIECE IS 1500'. Z = FINAL PUT-UP LENGTH MAY VARY (+ OR -) 10% FOR SPOOLS OR REELS AND(+ OR -) 5% FOR UNREEL CARTONS FROM LENGTH SHOWN. Revision Number: 4 Revision Date: 05-17-2015 © 2017 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale. Page 2 of 3 01-05-2017 Detailed Specifications & Technical Data ENGLISH MEASUREMENT VERSION 9318 Multi-Conductor - 300V Power-Limited Tray Cable All sales of Belden products are subject to Belden's standard terms and conditions of sale. Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the compliance date may be in stock at Belden facilities and in our Distributor’s inventory. The information provided in this Product Disclosure, and the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Belden’s knowledge, information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product. Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 2014/35/EU). Page 3 of 3 01-05-2017
9318 0601000 价格&库存

很抱歉,暂时无法提供与“9318 0601000”相匹配的价格&库存,您可以联系我们找货

免费人工找货