0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
3GE-B500

3GE-B500

  • 厂商:

    BELDEN

  • 封装:

  • 描述:

    BELDEN - 3GE-B500 - Multicore Cable, MachFlex 350 YY Control, Unscreened, 3 Core, 2.5 mm², 1640 ft, ...

  • 数据手册
  • 价格&库存
3GE-B500 数据手册
      Technical Data Sheet – Unshielded (YY) PVC Control Cable  MachFlex 350 YY    VDE Registered Flexible PVC Control Cables  Applications  Designed  for  applications  which  are  installed  in  occasional  flexing  and  fixed  locations.  Cable  applications  include  precision  control  sensors,  multi  axis  control  machines,  temperature  controllers,  control  panels,  machine cutting tools, auxiliary equipment, motor speed control, production machinery and many more.  General Reference Standards   DIN VDE 0295, IEC 60228, BS 6360  DIN EN 50290‐2‐22, DIN VDE 0207‐363‐4‐1  IEC 60227‐5, EN 50525‐2‐51, VDE 0281‐13  DIN VDE 0482‐332‐1‐2, DIN EN 60332‐1‐2, IEC 60332‐1‐2  RoHS, REACH & CE Directives Construction & Performance  1.  Conductor Material  Stranded bare copper (DIN VDE 0295 Class 5 / IEC 60228 class 5)  2.  Insulation Material & Colour  PVC (polyvinyl  chloride), DIN VDE 0293‐1 (colour)  A) All black colour with number coding = without protective earth conductor.                        OR  B) Black colour with number coding and 1 green & yellow colour conductor = with protective earth conductor.  3.  Jacket / Sheath Material  PVC (polyvinyl  chloride)  4.  Flame Retardancy  VDE 0482‐332‐1‐2, DIN EN 60332‐1‐2, IEC 60332‐1‐2  5.  Voltage Rating (Uo/U)  300 / 500 V  6.  Oil Resistant  DIN EN 50290‐2‐22 (TM54)  7. Temperature Range ‐30°C TO +70°C (Occasional movement)  ‐40°C TO +80°C (Fixed installation)  8. Bending Radius 10 x OD (Occasional movement)  4 x OD (Fixed installation)  9.  Other Properties  Good UV resistance, chemical resistance & flexibility  1 © 2014 Belden, Inc  All Rights Reserved.  Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to change without notice, and the listing of such information and  specifications does not ensure product availability. Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages  (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in  connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale.            Technical Data Sheet – Unshielded (YY) PVC Control Cable  TABLE A  Part Code  2X0.5  3X0.5  3G0.5  4X0.5  4G0.5  5X0.5  5G0.5  7X0.5  7G0.5  9X0.5  9G0.5  10X0.5  10G0.5  12X0.5  12G0.5  14X0.5  14G0.5  16X0.5  16G0.5  18X0.5  18G0.5  20X0.5  20G0.5  2X0.75  3X0.75  3G0.75  4X0.75  4G0.75  5X0.75  5G0.75  7X0.75  7G0.75  9X0.75  9G0.75  10X0.75  10G0.75  12X0.75  12G0.75  14X0.75  14G0.75  16X0.75  16G0.75  18X0.75  18G0.75  20X0.75  20G0.75  Cable  Description  2 X0.5  3 X0.5  3 G0.5  4 X0.5  4 G0.5  5 X0.5  5 G0.5  7 X0.5  7 G0.5  9 X0.5  9 G0.5  10 X0.5  10 G0.5  12 X0.5  12 G0.5  14 X0.5  14 G0.5  16 X0.5  16 G0.5  18 X0.5  18 G0.5  20 X0.5  20 G0.5  2 X0.75  3 X0.75  3 G0.75  4 X0.75  4 G0.75  5 X0.75  5 G0.75  7 X0.75  7 G0.75  9 X0.75  9 G0.75  10 X0.75  10 G0.75  12 X0.75  12 G0.75  14 X0.75  14 G0.75  16 X0.75  16 G0.75  18 X0.75  18 G0.75  20 X0.75  20 G0.75  No. Of  Cores  2  3  3  4  4  5  5  7  7  9  9  10  10  12  12  14  14  16  16  18  18  20  20  2  3  3  4  4  5  5  7  7  9  9  10  10  12  12  14  14  16  16  18  18  20  20  Nom. Conductor  Size (mm²)  0.5  0.5  0.5  0.5  0.5  0.5  0.5  0.5  0.5  0.5  0.5  0.5  0.5  0.5  0.5  0.5  0.5  0.5  0.5  0.5  0.5  0.5  0.5  0.75  0.75  0.75  0.75  0.75  0.75  0.75  0.75  0.75  0.75  0.75  0.75  0.75  0.75  0.75  0.75  0.75  0.75  0.75  0.75  0.75  0.75  0.75  Nom. Cable  Diameter (mm)  4.6  4.9  4.9  5.3  5.3  5.9  5.9  6.4  6.4  7.9  7.9  8.3  8.3  8.6  8.6  9.1  9.1  9.6  9.6  10.2  10.2  10.8  10.8  5.0  5.4  5.4  5.9  5.9  6.5  6.5  7.2  7.2  8.9  8.9  9.3  9.3  9.6  9.6  10.2  10.2  10.8  10.8  11.4  11.4  12.1  12.1  Nom. Cable Weight  (kg/km)  28  35  35  44  44  53  53  68  68  90  90  100  100  114  114  131  131  148  148  167  167  186  186  36  46  46  58  58  70  70  91  91  120  120  134  134  154  154  176  176  199  199  225  225  251  251  2 © 2014 Belden, Inc  All Rights Reserved.  Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to change without notice, and the listing of such information and  specifications does not ensure product availability. Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages  (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in  connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale.            Technical Data Sheet – Unshielded (YY) PVC Control Cable  Part Code  2X1.0  3X1.0  3G1.0  4X1.0  4G1.0  5X1.0  5G1.0  7X1.0  7G1.0  9X1.0  9G1.0  10X1.0  10G1.0  12X1.0  12G1.0  14X1.0  14G1.0  16X1.0  16G1.0  18X1.0  18G1.0  20X1.0  20G1.0  2X1.5  3X1.5  3G1.5  4X1.5  4G1.5  5X1.5  5G1.5  7X1.5  7G1.5  9X1.5  9G1.5  10X1.5  10G1.5  12X1.5  12G1.5  14X1.5  14G1.5  16X1.5  16G1.5  18X1.5  18G1.5  20X1.5  20G1.5  2X2.5  Cable  Description  2 X1.0  3 X1.0  3 G1.0  4 X1.0  4 G1.0  5 X1.0  5 G1.0  7 X1.0  7 G1.0  9 X1.0  9 G1.0  10 X1.0  10 G1.0  12 X1.0  12 G1.0  14 X1.0  14 G1.0  16 X1.0  16 G1.0  18 X1.0  18 G1.0  20 X1.0  20 G1.0  2 X1.5  3 X1.5  3 G1.5  4 X1.5  4 G1.5  5 X1.5  5 G1.5  7 X1.5  7 G1.5  9 X1.5  9 G1.5  10 X1.5  10 G1.5  12 X1.5  12 G1.5  14 X1.5  14 G1.5  16 X1.5  16 G1.5  18 X1.5  18 G1.5  20 X1.5  20 G1.5  2 X2.5  No. Of  Cores  2  3  3  4  4  5  5  7  7  9  9  10  10  12  12  14  14  16  16  18  18  20  20  2  3  3  4  4  5  5  7  7  9  9  10  10  12  12  14  14  16  16  18  18  20  20  2  Nom. Conductor  Size (mm²)  1.0  1.0  1.0  1.0  1.0  1.0  1.0  1.0  1.0  1.0  1.0  1.0  1.0  1.0  1.0  1.0  1.0  1.0  1.0  1.0  1.0  1.0  1.0  1.5  1.5  1.5  1.5  1.5  1.5  1.5  1.5  1.5  1.5  1.5  1.5  1.5  1.5  1.5  1.5  1.5  1.5  1.5  1.5  1.5  1.5  1.5  2.5  Nom. Cable  Diameter (mm)  5.4  5.8  5.8  6.4  6.4  7.1  7.1  7.8  7.8  9.6  9.6  10.1  10.1  10.5  10.5  11.0  11.0  11.7  11.7  12.4  12.4  13.2  13.2  6.0  6.4  6.4  7.0  7.0  7.8  7.8  8.5  8.5  10.6  10.6  11.1  11.1  11.5  11.5  12.2  12.2  12.9  12.9  13.7  13.7  14.5  14.5  7.7  Nom. Cable Weight  (kg/km)  44  57  57  72  72  89  89  115  115  151  151  169  169  195  195  224  224  255  255  287  287  319  319  55  71  71  91  91  112  112  145  145  191  191  213  213  247  247  284  284  323  323  364  364  405  405  91  3 © 2014 Belden, Inc  All Rights Reserved.  Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to change without notice, and the listing of such information and  specifications does not ensure product availability. Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages  (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in  connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale.            Technical Data Sheet – Unshielded (YY) PVC Control Cable  Part Code  3X2.5  3G2.5  4X2.5  4G2.5  5X2.5  5G2.5  7X2.5  7G2.5  9X2.5  9G2.5  10X2.5  10G2.5  12X2.5  12G2.5  14X2.5  14G2.5  16X2.5  16G2.5  18X2.5  18G2.5  20X2.5  20G2.5  2X4  3X4  3G4  4X4  4G4  5X4  5G4  7X4  7G4  9X4  9G4  10X4  10G4  12X4  12G4  2X6  3X6  3G6  4X6  4G6  5X6  5G6  7X6  7G6  9X6  Cable  Description  3 X2.5  3 G2.5  4 X2.5  4 G2.5  5 X2.5  5 G2.5  7 X2.5  7 G2.5  9 X2.5  9 G2.5  10 X2.5  10 G2.5  12 X2.5  12 G2.5  14 X2.5  14 G2.5  16 X2.5  16 G2.5  18 X2.5  18 G2.5  20 X2.5  20 G2.5  2 X4  3 X4  3 G4  4 X4  4 G4  5 X4  5 G4  7 X4  7 G4  9 X4  9 G4  10 X4  10 G4  12 X4  12 G4  2 X6  3 X6  3 G6  4 X6  4 G6  5 X6  5 G6  7 X6  7 G6  9 X6  No. Of  Cores  3  3  4  4  5  5  7  7  9  9  10  10  12  12  14  14  16  16  18  18  20  20  2  3  3  4  4  5  5  7  7  9  9  10  10  12  12  2  3  3  4  4  5  5  7  7  9  Nom. Conductor  Size (mm²)  2.5  2.5  2.5  2.5  2.5  2.5  2.5  2.5  2.5  2.5  2.5  2.5  2.5  2.5  2.5  2.5  2.5  2.5  2.5  2.5  2.5  2.5  4  4  4  4  4  4  4  4  4  4  4  4  4  4  4  6  6  6  6  6  6  6  6  6  6  Nom. Cable  Diameter (mm)  8.3  8.3  9.2  9.2  10.1  10.1  11.2  11.2  13.9  13.9  14.6  14.6  15.2  15.2  16.0  16.0  17.0  17.0  18.1  18.1  19.2  19.2  9.1  9.8  9.8  10.9  10.9  12.0  12.0  13.3  13.3  16.6  16.6  17.5  17.5  18.1  18.1  11.0  11.8  11.8  13.1  13.1  14.5  14.5  16.0  16.0  20.1  Nom. Cable Weight  (kg/km)  118  118  152  152  188  188  244  244  322  322  360  360  417  417  481  481  548  548  618  618  688  688  137  182  182  235  235  292  292  383  383  504  504  564  564  655  655  202  269  269  349  349  434  434  570  570  751  4 © 2014 Belden, Inc  All Rights Reserved.  Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to change without notice, and the listing of such information and  specifications does not ensure product availability. Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages  (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in  connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale.            Technical Data Sheet – Unshielded (YY) PVC Control Cable  Part Code  9G6  2X10  3X10  3G10  4X10  4G10  5X10  5G10  7X10  7G10  9X10  9G10  2X16  3X16  3G16  4X16  4G16  5X16  5G16  7X16  7G16  2X25  3X25  3G25  4X25  4G25  5X25  5G25  7X25  7G25  2X35  3X35  3G35  4X35  4G35  Cable  Description  9 G6  2 X10  3 X10  3 G10  4 X10  4 G10  5 X10  5 G10  7 X10  7 G10  9 X10  9 G10  2 X16  3 X16  3 G16  4 X16  4 G16  5 X16  5 G16  7 X16  7 G16  2 X25  3 X25  3 G25  4 X25  4 G25  5 X25  5 G25  7 X25  7 G25  2 X35  3 X35  3 G35  4 X35  4 G35      Sheath / Jacket Colour      Colour     1) Grey (RAL 7001)  2) Black      3) Blue      4) Orange     5) Violet                       No. Of  Cores  9  2  3  3  4  4  5  5  7  7  9  9  2  3  3  4  4  5  5  7  7  2  3  3  4  4  5  5  7  7  2  3  3  4  4              Nom. Conductor  Size (mm²)  6  10  10  10  10  10  10  10  10  10  10  10  16  16  16  16  16  16  16  16  16  25  25  25  25  25  25  25  25  25  35  35  35  35  35                                      Nom. Cable  Diameter (mm)  20.1  13.8  14.8  14.8  16.5  16.5  18.3  18.3  20.3  20.3  25.5  25.5  16.8  18.1  18.1  20.2  20.2  22.4  22.4  24.8  24.8  20.8  22.3  22.3  24.9  24.9  27.7  27.7  30.6  30.6  24.0  25.9  25.9  28.9  28.9                          Nom. Cable Weight  (kg/km)  751  320  427  427  555  555  692  692  910  910  1198  1198  497  668  668  870  870  1086  1086  1433  1433  770  1038  1038  1354  1354  1693  1693  2229  2229  1013  1365  1365  1780  1780  Colour Code    G8U    010    006    003    007  5 © 2014 Belden, Inc  All Rights Reserved.  Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to change without notice, and the listing of such information and  specifications does not ensure product availability. Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages  (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in  connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale.            Technical Data Sheet – Unshielded (YY) PVC Control Cable      Packaging    *Belden can offer these cables with various packing options like coiled, plastic or wooden reels. This  will be decided at the discretion of Belden based on the cable design and structure.       Put‐up Length    Putup Length                    Putup Length Code  1) 100 Meters*                    100M  2) 200 Meters*                    200M    3) 300 Meters                    300M  *Applicable only for certain part codes, please check with Belden for more information.      Stock Code Selection Procedure:      5 G 2 . 5 G G 2 . U 2 Select the sheath / jacket color code Select the part code from Table A 5 8 5 G 0 0 M Select the putup length code 8 U 2 0 0 M Cable Stock Code = 5G2.5 G8U200M 6 © 2014 Belden, Inc  All Rights Reserved.  Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to change without notice, and the listing of such information and  specifications does not ensure product availability. Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages  (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in  connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale. 
3GE-B500 价格&库存

很抱歉,暂时无法提供与“3GE-B500”相匹配的价格&库存,您可以联系我们找货

免费人工找货