0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
8618 060500

8618 060500

  • 厂商:

    BELDEN

  • 封装:

  • 描述:

    CBL 3COND 16AWG SHLD

  • 数据手册
  • 价格&库存
8618 060500 数据手册
Detailed Specifications & Technical Data ENGLISH MEASUREMENT VERSION 8618 Multi-Conductor - Audio, Control and Instrumentation Cable For more Information please call 1-800-Belden1 General Description: 16 AWG stranded (19x29) tinned copper conductors, conductors cabled, polyethylene insulation, overall Beldfoil® shield (100% coverage), 18 AWG stranded tinned copper drain wire, PVC jacket. Physical Characteristics (Overall) Conductor AWG: # Conductors AWG Stranding Conductor Material 3 16 19x29 TC - Tinned Copper Total Number of Conductors: 3 Insulation Insulation Material: Insulation Material Wall Thickness (in.) PE - Polyethylene 0.032 Outer Shield Outer Shield Material: Outer Shield Trade Name Type Outer Shield Material Beldfoil® (Z-Fold®) Coverage (%) Tape Aluminum Foil-Polyester Tape 100 Outer Shield Drain Wire AWG: AWG Stranding Drain Wire Conductor Material 18 16x30 TC - Tinned Copper Outer Jacket Outer Jacket Material: Outer Jacket Material Nom. Wall Thickness (in.) PVC - Polyvinyl Chloride .031 Overall Cable Overall Cabling Color Code Chart: Number Color 1 Black 2 Red 3 Clear Overall Nominal Diameter: 0.327 in. Mechanical Characteristics (Overall) Operating Temperature Range: -20°C To +80°C UL Temperature Rating: 80°C (UL AWM Style 20253) Bulk Cable Weight: 60 lbs/1000 ft. Max. Recommended Pulling Tension: 110 lbs. Min. Bend Radius/Minor Axis: 3.500 in. Applicable Specifications and Agency Compliance (Overall) Applicable Standards & Environmental Programs NEC/(UL) Specification: CL3 AWM Specification: UL Style 20253 (600 V 80°C) EU Directive 2011/65/EU (ROHS II): Yes EU CE Mark: Yes EU Directive 2000/53/EC (ELV): Yes EU Directive 2002/95/EC (RoHS): Yes EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2004 EU Directive 2002/96/EC (WEEE): Yes Page 1 of 2 01-05-2017 Detailed Specifications & Technical Data ENGLISH MEASUREMENT VERSION 8618 Multi-Conductor - Audio, Control and Instrumentation Cable EU Directive 2002/96/EC (WEEE): Yes EU Directive 2003/11/EC (BFR): Yes CA Prop 65 (CJ for Wire & Cable): Yes MII Order #39 (China RoHS): Yes Flame Test UL Flame Test: UL1685 UL Loading Plenum/Non-Plenum Plenum (Y/N): No Electrical Characteristics (Overall) Nom. Capacitance Conductor to Conductor: Capacitance (pF/ft) 26 Nom. Capacitance Cond. to Other Conductor & Shield: Capacitance (pF/ft) 50 Nom. Conductor DC Resistance: DCR @ 20°C (Ohm/1000 ft) 4.8 Max. Operating Voltage - UL: Voltage Description 600 V RMS AWM Style 2107 300 V RMS CL3 Max. Recommended Current: Current 7 Amps per conductor @ 25°C Put Ups and Colors: Item # Putup Ship Weight Color 8618 060U500 500 FT 31.500 LB CHROME Notes Item Desc 8618 0601000 1,000 FT 67.000 LB CHROME C 3 #16 LDPE FS PVC 8618 060500 500 FT 33.000 LB CHROME C 3 #16 LDPE FS PVC 8618 0605000 5,000 FT 325.000 LB CHROME 3 #16 LDPE FS PVC 3 #16 LDPE FS PVC Notes: C = CRATE REEL PUT-UP. Revision Number: 3 Revision Date: 08-03-2012 © 2017 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale. Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the compliance date may be in stock at Belden facilities and in our Distributor’s inventory. The information provided in this Product Disclosure, and the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Belden’s knowledge, information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product. Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 2014/35/EU). Page 2 of 2 01-05-2017
8618 060500 价格&库存

很抱歉,暂时无法提供与“8618 060500”相匹配的价格&库存,您可以联系我们找货

免费人工找货