0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
1345F T5U1000

1345F T5U1000

  • 厂商:

    BELDEN

  • 封装:

  • 描述:

    CBL 2/15AWG 2/18AWG SHLD

  • 数据手册
  • 价格&库存
1345F T5U1000 数据手册
Detailed Specifications & Technical Data ENGLISH MEASUREMENT VERSION 1345F Multi-Conductor - High-Flex DeviceBus® for ODVA DeviceNet™ For more Information please call 1-800-Belden1 General Description: 15 and 18 AWG stranded tinned copper conductors, PVC insulation (power), FPE insulation (data), individually foil shielded (100% coverage) plus an overall tinned copper braid (65% coverage), sunlight/oil-resistant TPE jacket. Physical Characteristics (Overall) Conductor AWG: # Pairs AWG Stranding Conductor Material 1 15 65x33 TC - Tinned Copper 1 18 65x36 TC - Tinned Copper Total Number of Conductors: 4 Insulation Insulation Material: Insulation Material AWG PVC - Polyvinyl Chloride 15 FPE - Foam Polyethylene 18 Inner Shield Inner Shield Material: Layer # Type Inner Shield Material Coverage (%) 15 AWG Pair Tape Aluminum Foil-Polyester Tape 100 18 AWG Pair Tape Aluminum Foil-Polyester Tape 100 Outer Shield Outer Shield Material: Type Outer Shield Material Coverage (%) Braid TC - Tinned Copper 65 Outer Shield Drain Wire AWG: AWG Stranding Drain Wire Conductor Material 18 65x36 TC - Tinned Copper Outer Jacket Outer Jacket Material: Outer Jacket Material Nom. Wall Thickness (in.) TPE - Thermoplastic Elastomer .060 Overall Cable Overall Nominal Diameter: 0.480 in. Pair Pair Color Code Chart: Number Color 1 (15 AWG) Red & Black 2 (18 AWG) Blue & White Mechanical Characteristics (Overall) Operating Temperature Range: -30°C To +75°C UL Temperature Rating: 75°C (UL AWM Style 20201) Bulk Cable Weight: 133 lbs/1000 ft. Max. Recommended Pulling Tension: 205 lbs. Min. Bend Radius/Minor Axis: 4.600 in. Applicable Specifications and Agency Compliance (Overall) Applicable Standards & Environmental Programs NEC/(UL) Specification: CMG, PLTC-ER Page 1 of 3 01-05-2017 Detailed Specifications & Technical Data ENGLISH MEASUREMENT VERSION 1345F Multi-Conductor - High-Flex DeviceBus® for ODVA DeviceNet™ CEC/C(UL) Specification: CMG AWM Specification: UL Style 20201 (600 V 75°C) CSA Specification: I/II A EU Directive 2011/65/EU (ROHS II): Yes EU CE Mark: Yes EU Directive 2000/53/EC (ELV): Yes EU Directive 2002/95/EC (RoHS): Yes EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005 EU Directive 2002/96/EC (WEEE): Yes EU Directive 2003/11/EC (BFR): Yes CA Prop 65 (CJ for Wire & Cable): Yes MII Order #39 (China RoHS): Yes Other Specification: ODVA Class 2 Thick Flame Test UL Flame Test: UL1685 FT4 Loading CSA Flame Test: FT4 Suitability Sunlight Resistance: Yes Oil Resistance: Yes Plenum/Non-Plenum Plenum (Y/N): No Electrical Characteristics (Overall) Unaveraged Impedance: Description Freq. (MHz) Start Freq. (MHz) Stop Freq. (MHz) Impedance (Ohm) 18 AWG Pair Only 120 Nom. Inductance: Description Inductance (µH/ft) 15 AWG Pair Only .174 Nom. Capacitance Conductor to Conductor: Description Freq. (MHz) Start Freq. (MHz) Stop Freq. (MHz) Capacitance (pF/ft) 18 AWG Pair Only 1 12.0 Nominal Velocity of Propagation: Description VP (%) 18 AWG Pair Only 75 Maximum Delay: Description Freq. (MHz) Start Freq. (MHz) Stop Freq. (MHz) Delay (ns/ft) 18 AWG Pair Only 1.36 Nom. Conductor DC Resistance: Description DCR @ 20°C (Ohm/1000 ft) 15 AWG 3.6 18 AWG 6.9 Nominal Outer Shield DC Resistance: DCR @ 20°C (Ohm/1000 ft) 1.8 Max. Attenuation: () Description Freq. (MHz) .13 18 AWG Pair Only .125 .26 .500 .40 1.00 Max. Operating Voltage - UL: Voltage Description 300 V RMS C(UL) AWM Max. Recommended Current: Description Current 15 AWG 8.0 Amps 18 AWG 5.0 Amps Page 2 of 3 01-05-2017 Detailed Specifications & Technical Data ENGLISH MEASUREMENT VERSION 1345F Multi-Conductor - High-Flex DeviceBus® for ODVA DeviceNet™ Notes (Overall) Notes: High-Flex. Thick. Meter marks on jacket to aid users in installation. ODVA DeviceNet is an Open DeviceNet Vendor Association, Inc. trademark. Jacket printed "1PR16" instead of "1PR15" due to UL requirements for CMG Listing. Put Ups and Colors: Item # Putup Ship Weight Color Notes Item Desc 1345F T5U1000 1,000 FT 133.000 LB GRAY T5U C 2 #15, 2 #18 SH TPE Notes: C = CRATE REEL PUT-UP. Revision Number: 2 Revision Date: 08-01-2012 © 2017 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale. Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the compliance date may be in stock at Belden facilities and in our Distributor’s inventory. The information provided in this Product Disclosure, and the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Belden’s knowledge, information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product. Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 2014/35/EU). Page 3 of 3 01-05-2017
1345F T5U1000 价格&库存

很抱歉,暂时无法提供与“1345F T5U1000”相匹配的价格&库存,您可以联系我们找货

免费人工找货