Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
9913 Coax - RG-8/U Type
For more Information
please call
1-800-Belden1
General Description:
10 AWG solid .108" bare copper conductor, semi-solid polyethylene insulation, Duobond II® + tinned
copper braid shield (90% coverage), PVC jacket.
Physical Characteristics (Overall)
Conductor
AWG:
# Coax AWG Stranding Conductor Material Dia. (in.)
1
10
Solid
BC - Bare Copper
.108
Total Number of Conductors:
1
Insulation
Insulation Material:
Insulation Material
Dia. (in.)
Semi-Solid PE - Semi-Solid Polyethylene .286
Outer Shield
Outer Shield Material:
Layer # Outer Shield Trade Name Type Outer Shield Material
1
Bonded DuoFoil®
2
Coverage (%)
Tape Bonded Aluminum Foil-Polyester Tape-Aluminum Foil 100
Braid TC - Tinned Copper
90
Outer Jacket
Outer Jacket Material:
Outer Jacket Material
PVC - Polyvinyl Chloride
Overall Cable
Overall Nominal Diameter:
0.405 in.
Mechanical Characteristics (Overall)
Operating Temperature Range:
-40°C To +80°C
Non-UL Temperature Rating:
75°C
Bulk Cable Weight:
107 lbs/1000 ft.
Max. Recommended Pulling Tension:
300 lbs.
Min. Bend Radius/Minor Axis:
4 in.
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
EU Directive 2011/65/EU (ROHS II):
Yes
EU CE Mark:
Yes
EU Directive 2000/53/EC (ELV):
Yes
EU Directive 2002/95/EC (RoHS):
Yes
EU RoHS Compliance Date (mm/dd/yyyy):
01/01/2004
EU Directive 2002/96/EC (WEEE):
Yes
EU Directive 2003/11/EC (BFR):
Yes
CA Prop 65 (CJ for Wire & Cable):
Yes
MII Order #39 (China RoHS):
Yes
RG Type:
8/U
Plenum/Non-Plenum
Plenum (Y/N):
No
Plenum Number:
89913
Page 1 of 3
01-05-2017
Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
9913 Coax - RG-8/U Type
Electrical Characteristics (Overall)
Nom. Characteristic Impedance:
Impedance (Ohm)
50
Nom. Inductance:
Inductance (µH/ft)
.059
Nom. Capacitance Conductor to Shield:
Capacitance (pF/ft)
24.6
Nominal Velocity of Propagation:
VP (%)
84
Nominal Delay:
Delay (ns/ft)
1.2
Nom. Conductor DC Resistance:
DCR @ 20°C (Ohm/1000 ft)
.9
Nominal Outer Shield DC Resistance:
DCR @ 20°C (Ohm/1000 ft)
1.8
Nom. Attenuation:
Freq. (MHz) Attenuation (dB/100 ft.)
5.000
0.400
10.000
0.500
50.000
1.000
100.000
1.400
200.000
1.800
400.000
2.600
700.000
3.600
900.000
4.100
1000.000
4.400
Max. Power Rating:
Freq. (MHz) Rating (W)
5.000
4021.000
10.000
3217.000
50.000
1609.000
100.000
1149.000
200.000
894.000
400.000
619.000
700.000
447.000
900.000
393.000
1000.000
366.000
Max. Operating Voltage - Non-UL:
Voltage
600 V RMS
Notes (Overall)
Notes: Recommend use of 7810R, 7810A, 9913F7, or 9914 for applications above 1 GHz.
Put Ups and Colors:
Item #
Putup
Ship Weight
Color
Notes
Item Desc
9913 010100
100 FT
14.200 LB
BLACK
C
RG-8/U TYPE COAX
9913 0101000
1,000 FT
116.000 LB
BLACK
C
RG-8/U TYPE COAX
9913 010250
250 FT
31.750 LB
BLACK
C
RG-8/U TYPE COAX
9913 010500
500 FT
57.000 LB
BLACK
C
RG-8/U TYPE COAX
9913 0105000
5,000 FT
625.000 LB
BLACK
C
RG-8/U TYPE COAX
Notes:
C = CRATE REEL PUT-UP.
Page 2 of 3
01-05-2017
Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
9913 Coax - RG-8/U Type
Revision Number: 2
Revision Date: 07-29-2013
© 2017 Belden, Inc
All Rights Reserved.
Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to
change without notice, and the listing of such information and specifications does not ensure product availability.
Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for
any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether
in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein.
All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the compliance date may be in stock at Belden facilities
and in our Distributor’s inventory. The information provided in this Product Disclosure, and the identification of materials listed as reportable or restricted within the Product Disclosure, is
correct to the best of Belden’s knowledge, information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide for the
safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not to be considered a warranty or quality specification.
Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the
product.
Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 2014/35/EU).
Page 3 of 3
01-05-2017
很抱歉,暂时无法提供与“9913 0101000”相匹配的价格&库存,您可以联系我们找货
免费人工找货