0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
201 5A

201 5A

  • 厂商:

    ETA(钰泰半导体)

  • 封装:

  • 描述:

    ETA - 201 5A - Thermal Magnetic Circuit Breaker, 201, 5 A, 1 Pole, 65 VDC, 250 VAC, DIN Rail

  • 数据手册
  • 价格&库存
201 5A 数据手册
Thermal-Magnetic Circuit Breaker 201/-WA Description Single pole thermal-magnetic circuit breaker with tease-free, trip-free, snap action mechanism and two button operation (M-type TM CBE to EN 60934). Featuring a narrow profile housing, recessed terminals, standard EN rail mounting, and precision CBE performance. Approved to CBE standard EN 60934 (IEC 60934). Typical applications Process control systems, instrumentation, rail vehicles. 201-... standard type Ordering information 10 A ordering example The exact part number required can be built up from the table of choices shown above. Ordering references for optional features should be omitted if not required. Standard current ratings and typical internal resistance values Current rating (A) Internal resistance (Ω) 201 201-WA Current rating (A) Internal resistance (Ω) 201 201-WA 0.05 0.1 0.2 0.3 0.4 0.5 0.6 0.8 1 1.5 2 2.5 447 131 40 19.3 10.4 7.1 4.3 2.5 1.67 0.61 0.38 0.24 3 4 5 6 7 8 10 12 14 15 16 0.19 0.090 0.061 0.041 0.034 < 0.02 < 0.02 < 0.02 < 0.02 < 0.02 < 0.02 211 48 12.4 5.7 3.1 2.0 1.32 0.76 0.49 0.21 0.101 0.078 0.054 0.035 0.025 < 0.02 < 0.02 < 0.02 < 0.02 For further details please see chapter: Technical Information Voltage rating AC 240 V (50/60 Hz); DC 65 V (UL: AC 250 V, DC 80 V) Current rating range 201: 0.05...16 A 201-WA: 0.05...10 A Typical life 5,000 operations at 1 x IN, inductive 5,000 operations at 2 x IN, resistive Ambient temperature -30...+60 °C (-22...+140 °F) Insulation co-ordination rated impulse pollution (IEC 60664 and 60664 A) withstand voltage degree 2.5 kV 2 reinforced insulation in operating area Dielectric strength (IEC 60664 and 60664A) test voltage operating area AC 3,000 V Insulation resistance > 100 MΩ (DC 500 V) Interrupting capacity Icn 201 201-WA 0.05...0.8 A 1...2 A 2.5...16 A Interrupting capacity (UL 1077) Degree of protection (IEC 60529/DIN 40050) Vibration Shock Corrosion Humidity Approvals Mass Authority VDE (EN 60 934) CSA, UL 05/06(020505) 2 Technical data Type No. 201 single pole, rail mounted version 201-WA low-resistance version Option 2705 fitted with adapter X 200 409 01 Current ratings 0.05...16 A (type 201) 0.05...10 A (type 201-WA) 201 - .. - .... - 201-WA-... low-resistance type Voltage ratings AC 240 V, DC 65 V AC 250 V, DC 80 V Current ratings 0.05...16 A 0.05...16 A www.e-t-a.com 0.05...0.2 A 0.3...2 A 2.5...10 A self-limiting 200 A 400 A IN UN 0.05...16 A AC 250 V 1,000 A 0.05...16 A DC 80 V 1,000 A operating area IP40 terminal area IP20 5 g (57-500 Hz), ±0.38 mm (10-57 Hz) to IEC 60068-2-6, test Fc 10 frequency cycles/axis 25 g (11 ms) to IEC 60068-2-27, test Ea 96 hours at 5 % salt mist, to IEC 60068-2-11, test Ka 240 hours at 95 % RH to IEC 60068-2-3, test Ca approx. 60 g Thermal-Magnetic Circuit Breaker 201/-WA Installation drawing 5 .197 45 1.77 ø8.5 .335 11.5 .453 black ON OFF 11 .433 Dimensions 43 1.69 53 2.09 white 80 3.15 cable entry cable entry mounting area 6.5 .256 7.5 .295 2 4.8 .189 12-14 .472-.551 operating area (reinforced insulation) conductor cross section max. 0.5 - 10 mm2 (AWG 20-AWG 8) rigid conductor 0.5 - 6 mm2 (AWG 20-AWG 10) flexible conductor tightening torque max. 0.8 Nm 12.5 .492 symmetrical rail EN 50022-35x7.5 current rating in A slot for fitting labels from 2 Weidmüller type dekafix Phoenix type ZBFM5 or ZB8 Phillips screw, size 2 to EN ISO 4757 Internal connection diagram This is a metric design and millimeter dimensions take precedence ( mm ) inch line 1 The time/current characteristic curve depends on the ambient temperature prevailing. In order to eliminate nuisance tripping, please multiply the circuit breaker current ratings by the derating factor shown below. See also section 9 – Technical information. Ambient temperature °F -22 -4 +14 +32 +73.4 +104 +122 +140 °C -30 -20 -10 0 +23 +40 +50 +60 Derating factor 0.76 0.79 0.83 0.88 1 1.08 1.16 1.24 I> 2 Typical time/current characteristics AC/DC 1) Type 201 0.05...7 A Type 201 8...16 A 1000 100 100 100 10 1 Trip time in seconds 1000 Trip time in seconds 1000 Trip time in seconds 10000 10 1 0.1 0.01 0.01 0.01 0.001 +60 °C +140 °F 4 6 8 10 20 40 60 80100 … times rated current +23 °C +73.4 °F DC/AC 2) 1 0.1 2 0.05...10 A 10 0.1 1 2) Type 201-WA 10000 0.001 1) AC/DC 1) 10000 0.001 1 2 4 6 8 10 20 40 60 80100 … times rated current 1 2 4 6 8 10 20 40 60 80100 … times rated current -30 °C -22 °F Magnetic tripping currents are increased by 20% on DC supplies. Magnetic tripping currents are decreased by 20% on AC supplies. 120 www.e-t-a.com 05/06(020505) Thermal-Magnetic Circuit Breaker 201/-WA Accessories 20 .787 Adapter for EN rail 50035-G32 specified as a separate item X 200 409 01 Adapter X 200 409 01 G profile EN 50035-G32 2 Connector bus links -K10 X 210 589 01/2.5 mm2, (AWG 14) (black) up to 20 A max. load X 210 589 02/1.5 mm2, (AWG 16) (brown) up to 13 A max. load ø2.5 .099 ~70 ~2.76 50 pin lugs to DIN 46230 tinned copper Bus bar X 221 498 01 (17-way) up to 70 A max. load 16 x 12.5 = 200 16 x .492 = 7.87 12.5 .492 2.5 .099 1.3 207 8.15 14 .551 IEC 664 500 V/70 A (40 °C) CE E-T-A® GERMANY 29 1.14 .051 3.5 .138 9.7 .382 2.5 .098 M5 13 .512 17 .669 5.2 .205 1.3 .051 22 .866 11.3 .445 Supply terminal for bus bar X 221 496 01 up to 70 A max. load 4.6 .181 conductor size max. 10 mm2 (AWG 8) rigid, solid or stranded 14.5 .571 This is a metric design and millimeter dimensions take precedence ( mm ) inch 05/06(020505) All dimensions without tolerances are for reference only. In the interest of improved design, performance and cost effectiveness the right to make changes in these specifications without notice is reserved.Product markings may not be exactly as the ordering codes. Errors and omissions excepted. www.e-t-a.com
201 5A 价格&库存

很抱歉,暂时无法提供与“201 5A”相匹配的价格&库存,您可以联系我们找货

免费人工找货