3130-FA2A-P7T1-W01Q-3A-A040001M 数据手册
Thermal Overcurrent Circuit Breaker 3130
Description
Single, two and three pole rocker switch/thermal trip free circuit breakers
(S-type TO CBE to EN 60934) of compact design for snap-in panel
mounting. Available either with protection on one/both/all poles or,
in the case of the double pole version, protection on one pole only.
Illumination is optional and there is a choice of rocker colours.
Approved to CBE standard EN 60934 (IEC 60934).
Typical applications
Motors, transformers, solenoids, household and office machines, electrical
tools, mobile homes, boating, construction vehicles, medical equipment
to EN 60601.
1-pole
3130
1
3-pole
Standard current ratings and typical internal resistance values
Technical data
Current
rating (A)
Internal resistance Current
per pole (Ω)
rating (A)
Internal resistance
per pole (Ω)
0.1
94
0.0435
4
0.2
24
5
0.0325
0.3
12
6
0.0215
0.4
5.30
7
0.0165
0.5
4.20
8
0.0165
0.8
1.50
10
< 0.02
1
0.9
12
< 0.02
1.2
0.80
14
< 0.02
1.5
0.45
15
< 0.02
2
0.27
16
< 0.02
2.5
0.0785
18
< 0.02
3
0.0595
20
< 0.02
3.5
0.0565
Illumination voltage/power consumption
operating voltage
power consumption
1-pole
2-/3-pole
2-/3-pole
Y+R
G
12 V
9 mA
2 mA
3.5 mA
24 V
9 mA
2 mA
3.5 mA
48 V
9 mA
2 mA
3.5 mA
115 V
< 1 mA
0.9 mA
2.8 mA
230 V
< 1 mA
0.9 mA
400 V
-
0.9 mA
For further details please see chapter: Technical Information
Voltage rating
AC 240 V; 3 AC 415 V; DC 50 V
(UL: AC 250 V; 3 AC 250 V; DC 50 V)
Current ratings
0.1...20 A 1-pole
0.1...16 A 2- and 3-pole
Typical life
1-pole
AC 240 V: 0.1...20 A 30,000 operations at 1 x IN, inductive
DC 50 V:
0.1...4 A 30,000 operations at 1 x IN, inductive
4.5...16 A 30,000 operations at 1 x IN, resistive
DC 28 V:
0.1...20 A 30,000 operations at 1 x IN, inductive
2-pole
AC 240 V: 0.1...16 A 50,000 operations at 1 x IN, inductive
DC 50 V:
0.1...16 A 50,000 operations at 1 x IN, inductive
3-pole
3 AC 415 V: 0.1...16 A 30,000 operations at 1 x IN, inductive
Ambient temperature
-30...+60 °C (-22...+140 °F)
Insulation co-ordination
rated impulse
pollution
(IEC 60664 and 60664 A) withstand voltage
degree
2.5 kV
2
reinforced insulation in operating area
Dielectric strength
(IEC 60664 and 60664A) test voltage
operating area
AC 3,000 V
current path/current path AC 1,500 V
Insulation resistance
> 100 MΩ (DC 500 V)
Interrupting capacity Icn 0.1...2 A
10 x IN
2.5...20 A
150 A
1-pole
2.5...16 A
250 A
2-pole
2.5...12 A
150 A
3-pole
14 + 16 A
130 A
3-pole
Interrupting capacity (UL 1077)
IN
UN
Inc
1, 2-pole
0.1...16 A
AC 250 V
3500 A
2.8 mA
3-pole
0.1...12 A
3 AC 250 V
5000 A
2.8 mA
1,2-pole
0.1...16 A
DC 50 V
2000 A
Degree of protection
(IEC 60529/DIN 40050)
Vibration
Shock
Corrosion
Humidity
Mass
1815
www.e-t-a.de
operating area IP40
terminal area IP00
5 g (57-500 Hz) ± 0.38 mm (10-57 Hz)
to IEC 60068-2-6, test Fc
10 frequency cycles/axis
1-pole: 25 g (11 ms) 2 + 3-pole: 20 g (11 ms)
to IEC 60068-2-27, test Ea
96 hours at 5 % salt mist,
to IEC 60068-2-11, test Ka
240 hours at 95 % RH,
to IEC 60068-2-78, test Cab
approx. 45 g (three pole)
approx. 31 g (double pole)
approx. 17 g (single pole)
1
Thermal Overcurrent Circuit Breaker 3130
Ordering information - 1-pole
1
Ordering information - multipole
Type No.
3130 single pole thermal circuit breaker
Mounting
F snap in frame
Frame
1 standard
Number of poles
1 single pole, thermally protected
Frame mounting
0 panel thickness 1-2.5 mm (.039-.099 in)
Terminal design
P7 blade terminals DIN 46244-C-Ms-S (QC 2x.110)
H7 for terminals 1.1, 2.1 3.1 terminal screws M 3.5
for terminals 1.2, 2.2, 3.2 blade terminals (QC 2x.110)
Characteristic curve
T1 thermal 1.05-1.4 IN
Actuator style
W rocker switch with marking „I“ and „O“
moulded in
Actuator colour
01 Q black opaque without illumination
02 Q white opaque without illumination
04 Q red opaque without illumination
14 Q R red translucent with LED-illumination
15 Q Y orange translucent with
LED-illumination
19 Q G green translucent with
LED-illumination (DC only)
Illumination voltage range*
2 10 - 14 V DC
3 20 - 28 V DC
6 90 - 140 V AC
7 185 - 275 V AC
Current ratings
0,1...20 A
3130 - F 1 1 0 - P7 T1 - W 14 Q R
3 - 5 A
ordering example
* N/A for non-illuminated version
Preferred types
Type No.
3130 multipole thermal circuit breaker
Mounting
F snap in frame
Frame
1 standard
A version for X3130
Number of poles
2 2-pole thermally protected
3 3-pole thermally protected
5 2-pole, 1-pole thermally protected
Frame mounting
0 panel thickness 1-2.5 mm (.039-.099 in)
A 2-pole, version for X3130
Terminal design
P7 blade terminals DIN 46244-C-Ms-S
(characteristic curve T1)
H7 for terminals 1.1, 2.1 3.1 terminal screws M 3.5
for terminals 1.2, 2.2, 3.2 blade terminals (QC 2x.110)
Characteristic curve
T1 thermal 1.05-1.4 IN
Actuator style
W rocker switch with marking „I“ and „O“
moulded in
Actuator colour
01 Q black opaque without illumination
02 Q white opaque without illumination
04 Q red opaque without illumination
14 Q R red translucent with
LED-illumination
15 Q Y orange translucent with
LED-illumination
19 Q G green translucent with
LED-illumination
Illumination voltage range*
2 10 - 14 V DC
3 20 - 28 V DC
6 90 - 140 V AC
7 185 - 275 V AC
8 320 - 450 V AC
Current ratings
0,1...16 A
3130 - F 1 3 0 - P7 T1 - W 14 Q R 7 - 5 A
Preferred types
3130 1-pole
3130-F110-P7T1W01Q-
Standard current ratings (A)
1
2
3
4
5
8
x
x
x
x
x
x
ordering example
* N/A for non-illuminated version
10 15 16 20
x
x
x
x
Approvals
Authority
Standard
Rated voltage Current ratings
VDE
IEC/EN
60934
UL
UL 1077
CSA
C22.2 No
235
AC 240 V
AC 240/415 V
DC 50 V
DC 50 V
DC 28 V
AC 250 V
AC 250 V
DC 50 V
AC 250 V
AC 250 V
DC 50 V
2
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
A…20 A (single pole)
A…16 A (multipole)
A…8 A (single pole)
A…16 A (multipole)
A…20 A (single pole)
A…16 A (1 + 2 pole)
A…12 A (3 pole)
A…16 A (1 – 3 pole)
A…16 A (1 + 2 pole)
A…12 A (3 pole)
A…16 A (1 – 3 pole)
www.e-t-a.de
1815
Thermal Overcurrent Circuit Breaker 3130
Dimensions
3130-F130-…
3130-F110-…
terminal for
illumination
conductor size
0.14 mm2 (AWG26),
length 180 mm
(7.09 in.)
LINE
I.I
I.3
2
.079
20
.787
2
.079
Side view
34
1.34
Side view
34
1.34
1
3
2
unit
I
blade terminals DIN 46244-C-Ms-S
(QC 2x.110 P7 or N7)
2
.079
20
.787
blade terminals DIN 46244-C-Ms-S
(QC 2x.110 P7 or N7)
LINE
I.I
LINE
I.I
min. 1.5
min .059
Panel cut-out
-0.4
-0.2
-.016
-.008
.5
< R0
20
< .0
±0.1
±.004
panel thickness
1-2.5 mm
(.039-.098 in.)
34+0.2
34+0.2
1.34+.008
+0.3
+.012
1.34+.008
+0.3
+.012
min. 1.5
min .059
36
1.42
37.6+0.2
1.48+.008
36
1.42
optional illumination
R
.1 3
18
.5
< R0
20
< .0
±0.1
±.004
14.6+0.2
18
.709
R3 8
.11
-0.4
-0.2
-.016
-.008
panel thickness
1-2.5 mm
(.039-.098 in.)
flat head screw M3.5x5 -MS ISO 1580 (H7)
tightening torque max. 0.8 Nm
Panel cut-out
41
1.61
flat head screw M3.5x5 -MS ISO 1580 (H7)
tightening torque max. 0.8 Nm
.575+.008
switch only
LINE
I.I
I.2
10
.394
I.2
ON
10
.394
I.3
OFF
9.5
.374
33
1.30
33
1.30
5.85
.230
2
.079
ON
37.5
1.48
32.5
1.28
5.85
.230
OFF
14.5
.571
optional illumination
Edges of working parts: DIN 6784
3130-F120-…
OFF
26
1.02
21
.827
Internal connection diagrams
5.85
.230
2
.079
ON
2-pole
33
1.30
1-pole
line 1.1
2.1
1 .2
load
2.2
load
LINE
I.I
I.2
10
.394
I.3
line 1.1
2
2
.079
20
.787
unit
I
1.3
blade terminals DIN 46244-C-Ms-S
(QC 2x.110 P7 or N7)
Side view
34
1.34
I.2
load
lamp
LINE
I.I
3-pole
panel thickness
1-2.5 mm
(.039-.098 in.)
36
1.42
optional illumination
2.1
3.1
1.2
load
2.2
load
3.2
load
min. 1.5
min .059
.5
< R0
20
< .0
34 +0.2
1.34 +.008
+0.3
+.012
26.1+0.2
29.5
1.16
±0.1
±.004
line 1.1
1.03+.008
R3
18
.1
flat head screw M3.5x5 -MS ISO 1580 (H7)
tightening torque max. 0.8 Nm
Panel cut-out
Edges of working parts: DIN 6784
This is a metric design and millimeter dimensions take precedence ( mm )
inch
1815
www.e-t-a.de
3
Thermal Overcurrent Circuit Breaker 3130
Typical time/current characteristics
Installation drawing 3130-F1...
Multipole types: all poles symmetrically loaded.
With single pole overload, thermal tripping will be at
approx. 1.54 x IN with 2-pole devices and at
approx. 1.68 x IN with 3-pole devices.
When installing the circuit breaker apply pressure on bezel only.
operating area
0.1…2 A
I.3
LINE
I.I
I.2
-30 °C
-22 °F
Trip time in seconds
32
1.26
1000
1
10
.394
+23 °C
+73.4 °F
25
.984
+60 °C
+140 °F
10000
100
5
.197
8
.315
10
20
.787
mounting area
7
.276
7
.276
Accessories 3130-F130-...
1
0.1
1
2
4
6 8 10
… times rated current
20
Splash cover, transparent, for 3-pole version
X 221 258 01 (IP54), comprising bezel Y 306 109 01
and transparent cover Y 306 108 01
40
2.5…20 A 1-pole
2.5…16 A 2- and 3-pole
41.5
1.63
+60 °C
+140 °F
10000
+23 °C
+73.4 °F
-30 °C
-22 °F
5
50
1.97
12
.472
100
.197
36.5
1.44
ø11
.433
10
55
2.17
ø4.4
.173
Trip time in seconds
1000
ø8
.315
1
0.1
1
2
4
6 8 10
… times rated current
20
50
1.97
40
The time/current characteristic curve depends on the ambient temperature
prevailing. In order to eliminate nuisance tripping, please multiply the circuit
breaker current ratings by the derating factor shown below. See also section
Technical information.
Ambient
temperature
Derating factor
°F
°C
-22
-30
-4
-20
+14
-10
+32
0
+73.4
+23
+104
+40
+122
+50
+140
+60
0.8
0.84
0.88
0.92
1
1.08
1.14
1.23
This is a metric design and millimeter dimensions take precedence ( mm )
inch
All dimensions without tolerances are for reference only. In the interest of improved design,
performance and cost effectiveness the right to make changes in these specifications
without notice is reserved.Product markings may not be exactly as the ordering codes.
Errors and omissions excepted.
4
www.e-t-a.de
1815
Appliance Inlet Module X3130 for 2-pole circuit breaker 3130-FA.A
Description
Technical data
Typical applications
Electrical medical apparatus, laboratory equipment, professional audio
equipment and office machines.
Ordering information
Number of poles
L, N + ground
Cable cross section
max. 1.5 mm2
Degree of protection
Mounting method
Class I
screw-type mounting (front or rear)
Terminal design
blade terminals DIN 46244 A6.3 x 0.8
Housing material
thermoplastics, black UL94V-0
Appliance inlet
Switch
C14 according to IEC/EN 60320-1, UL 498
circuit breaker type 3130, 2-pole
1
Dimensions
Circuit breaker 3130 (2-pole)
72
LINE
I.I
04 00 01 - M Ordering example
Ambient temperature
10 A (IEC)
15 A (UL/CSA)
-25°C ... 70°C
I.2
X3130 - A
AC 240 V
Rated current
I.3
Type No.
X3130 Appliance inlet module for circuit breaker type 3130-FA.A
Module
A appliance inlet C14
Design
04 screw-type mounting
Accessories
00 without
Version
00 not wired; mounting position 3130:
I to connector
01 not wired; mounting position 3130:
0 to connector (standard)
Delivery condition
M module supplied with
circuit breaker FA.A
Rated voltage
82
The appliance inlet module X3130 with double pole circuit breaker
3130-FA.A combines three functions within a single component: A C14
appliance inlet and rocker switch with resettable overcurrent protection;
screw mounting from the front or the rear.
Approvals
ENEC, UL, CSA, CCC
24
ø 3.3
36.5
40.2
Mounting hole X3130
31.6 ± 0.1
1.24
M3/Ø 3.3
Ø.130
63.6 ± 0.15
2.50
72 ± 0.2
2.83
1815
www.e-t-a.de
5