0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
3130-FA2A-P7T1-W01Q-3A-A040001M

3130-FA2A-P7T1-W01Q-3A-A040001M

  • 厂商:

    ETA(钰泰半导体)

  • 封装:

  • 描述:

    ETA - 3130-FA2A-P7T1-W01Q-3A-A040001M - Thermal Circuit Breaker, 3130, 3 A, 2 Pole, 50 V, 250 V, Pan...

  • 数据手册
  • 价格&库存
3130-FA2A-P7T1-W01Q-3A-A040001M 数据手册
Thermal Overcurrent Circuit Breaker 3130 Description Single, two and three pole rocker switch/thermal trip free circuit breakers (S-type TO CBE to EN 60934) of compact design for snap-in panel mounting. Available either with protection on one/both/all poles or, in the case of the double pole version, protection on one pole only. Illumination is optional and there is a choice of rocker colours. Approved to CBE standard EN 60934 (IEC 60934). Typical applications Motors, transformers, solenoids, household and office machines, electrical tools, mobile homes, boating, construction vehicles, medical equipment to EN 60601. 1-pole 3130 1 3-pole Standard current ratings and typical internal resistance values Technical data Current rating (A) Internal resistance Current per pole (Ω) rating (A) Internal resistance per pole (Ω) 0.1 94 0.0435 4 0.2 24 5 0.0325 0.3 12 6 0.0215 0.4 5.30 7 0.0165 0.5 4.20 8 0.0165 0.8 1.50 10 < 0.02 1 0.9 12 < 0.02 1.2 0.80 14 < 0.02 1.5 0.45 15 < 0.02 2 0.27 16 < 0.02 2.5 0.0785 18 < 0.02 3 0.0595 20 < 0.02 3.5 0.0565 Illumination voltage/power consumption operating voltage power consumption 1-pole 2-/3-pole 2-/3-pole Y+R G 12 V 9 mA 2 mA 3.5 mA 24 V 9 mA 2 mA 3.5 mA 48 V 9 mA 2 mA 3.5 mA 115 V < 1 mA 0.9 mA 2.8 mA 230 V < 1 mA 0.9 mA 400 V - 0.9 mA For further details please see chapter: Technical Information Voltage rating AC 240 V; 3 AC 415 V; DC 50 V (UL: AC 250 V; 3 AC 250 V; DC 50 V) Current ratings 0.1...20 A 1-pole 0.1...16 A 2- and 3-pole Typical life 1-pole AC 240 V: 0.1...20 A 30,000 operations at 1 x IN, inductive DC 50 V: 0.1...4 A 30,000 operations at 1 x IN, inductive 4.5...16 A 30,000 operations at 1 x IN, resistive DC 28 V: 0.1...20 A 30,000 operations at 1 x IN, inductive 2-pole AC 240 V: 0.1...16 A 50,000 operations at 1 x IN, inductive DC 50 V: 0.1...16 A 50,000 operations at 1 x IN, inductive 3-pole 3 AC 415 V: 0.1...16 A 30,000 operations at 1 x IN, inductive Ambient temperature -30...+60 °C (-22...+140 °F) Insulation co-ordination rated impulse pollution (IEC 60664 and 60664 A) withstand voltage degree 2.5 kV 2 reinforced insulation in operating area Dielectric strength (IEC 60664 and 60664A) test voltage operating area AC 3,000 V current path/current path AC 1,500 V Insulation resistance > 100 MΩ (DC 500 V) Interrupting capacity Icn 0.1...2 A 10 x IN 2.5...20 A 150 A 1-pole 2.5...16 A 250 A 2-pole 2.5...12 A 150 A 3-pole 14 + 16 A 130 A 3-pole Interrupting capacity (UL 1077) IN UN Inc 1, 2-pole 0.1...16 A AC 250 V 3500 A 2.8 mA 3-pole 0.1...12 A 3 AC 250 V 5000 A 2.8 mA 1,2-pole 0.1...16 A DC 50 V 2000 A Degree of protection (IEC 60529/DIN 40050) Vibration Shock Corrosion Humidity Mass 1815 www.e-t-a.de operating area IP40 terminal area IP00 5 g (57-500 Hz) ± 0.38 mm (10-57 Hz) to IEC 60068-2-6, test Fc 10 frequency cycles/axis 1-pole: 25 g (11 ms) 2 + 3-pole: 20 g (11 ms) to IEC 60068-2-27, test Ea 96 hours at 5 % salt mist, to IEC 60068-2-11, test Ka 240 hours at 95 % RH, to IEC 60068-2-78, test Cab approx. 45 g (three pole) approx. 31 g (double pole) approx. 17 g (single pole) 1 Thermal Overcurrent Circuit Breaker 3130 Ordering information - 1-pole 1 Ordering information - multipole Type No. 3130 single pole thermal circuit breaker Mounting F snap in frame Frame 1 standard Number of poles 1 single pole, thermally protected Frame mounting 0 panel thickness 1-2.5 mm (.039-.099 in) Terminal design P7 blade terminals DIN 46244-C-Ms-S (QC 2x.110) H7 for terminals 1.1, 2.1 3.1 terminal screws M 3.5 for terminals 1.2, 2.2, 3.2 blade terminals (QC 2x.110) Characteristic curve T1 thermal 1.05-1.4 IN Actuator style W rocker switch with marking „I“ and „O“ moulded in Actuator colour 01 Q black opaque without illumination 02 Q white opaque without illumination 04 Q red opaque without illumination 14 Q R red translucent with LED-illumination 15 Q Y orange translucent with LED-illumination 19 Q G green translucent with LED-illumination (DC only) Illumination voltage range* 2 10 - 14 V DC 3 20 - 28 V DC 6 90 - 140 V AC 7 185 - 275 V AC Current ratings 0,1...20 A 3130 - F 1 1 0 - P7 T1 - W 14 Q R 3 - 5 A ordering example * N/A for non-illuminated version Preferred types Type No. 3130 multipole thermal circuit breaker Mounting F snap in frame Frame 1 standard A version for X3130 Number of poles 2 2-pole thermally protected 3 3-pole thermally protected 5 2-pole, 1-pole thermally protected Frame mounting 0 panel thickness 1-2.5 mm (.039-.099 in) A 2-pole, version for X3130 Terminal design P7 blade terminals DIN 46244-C-Ms-S (characteristic curve T1) H7 for terminals 1.1, 2.1 3.1 terminal screws M 3.5 for terminals 1.2, 2.2, 3.2 blade terminals (QC 2x.110) Characteristic curve T1 thermal 1.05-1.4 IN Actuator style W rocker switch with marking „I“ and „O“ moulded in Actuator colour 01 Q black opaque without illumination 02 Q white opaque without illumination 04 Q red opaque without illumination 14 Q R red translucent with LED-illumination 15 Q Y orange translucent with LED-illumination 19 Q G green translucent with LED-illumination Illumination voltage range* 2 10 - 14 V DC 3 20 - 28 V DC 6 90 - 140 V AC 7 185 - 275 V AC 8 320 - 450 V AC Current ratings 0,1...16 A 3130 - F 1 3 0 - P7 T1 - W 14 Q R 7 - 5 A Preferred types 3130 1-pole 3130-F110-P7T1W01Q- Standard current ratings (A) 1 2 3 4 5 8 x x x x x x ordering example * N/A for non-illuminated version 10 15 16 20 x x x x Approvals Authority Standard Rated voltage Current ratings VDE IEC/EN 60934 UL UL 1077 CSA C22.2 No 235 AC 240 V AC 240/415 V DC 50 V DC 50 V DC 28 V AC 250 V AC 250 V DC 50 V AC 250 V AC 250 V DC 50 V 2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 A…20 A (single pole) A…16 A (multipole) A…8 A (single pole) A…16 A (multipole) A…20 A (single pole) A…16 A (1 + 2 pole) A…12 A (3 pole) A…16 A (1 – 3 pole) A…16 A (1 + 2 pole) A…12 A (3 pole) A…16 A (1 – 3 pole) www.e-t-a.de 1815 Thermal Overcurrent Circuit Breaker 3130 Dimensions 3130-F130-… 3130-F110-… terminal for illumination conductor size 0.14 mm2 (AWG26), length 180 mm (7.09 in.) LINE I.I I.3 2 .079 20 .787 2 .079 Side view 34 1.34 Side view 34 1.34 1 3 2 unit I blade terminals DIN 46244-C-Ms-S (QC 2x.110 P7 or N7) 2 .079 20 .787 blade terminals DIN 46244-C-Ms-S (QC 2x.110 P7 or N7) LINE I.I LINE I.I min. 1.5 min .059 Panel cut-out -0.4 -0.2 -.016 -.008 .5 < R0 20 < .0 ±0.1 ±.004 panel thickness 1-2.5 mm (.039-.098 in.) 34+0.2 34+0.2 1.34+.008 +0.3 +.012 1.34+.008 +0.3 +.012 min. 1.5 min .059 36 1.42 37.6+0.2 1.48+.008 36 1.42 optional illumination R .1 3 18 .5 < R0 20 < .0 ±0.1 ±.004 14.6+0.2 18 .709 R3 8 .11 -0.4 -0.2 -.016 -.008 panel thickness 1-2.5 mm (.039-.098 in.) flat head screw M3.5x5 -MS ISO 1580 (H7) tightening torque max. 0.8 Nm Panel cut-out 41 1.61 flat head screw M3.5x5 -MS ISO 1580 (H7) tightening torque max. 0.8 Nm .575+.008 switch only LINE I.I I.2 10 .394 I.2 ON 10 .394 I.3 OFF 9.5 .374 33 1.30 33 1.30 5.85 .230 2 .079 ON 37.5 1.48 32.5 1.28 5.85 .230 OFF 14.5 .571 optional illumination Edges of working parts: DIN 6784 3130-F120-… OFF 26 1.02 21 .827 Internal connection diagrams 5.85 .230 2 .079 ON 2-pole 33 1.30 1-pole line 1.1 2.1 1 .2 load 2.2 load LINE I.I I.2 10 .394 I.3 line 1.1 2 2 .079 20 .787 unit I 1.3 blade terminals DIN 46244-C-Ms-S (QC 2x.110 P7 or N7) Side view 34 1.34 I.2 load lamp LINE I.I 3-pole panel thickness 1-2.5 mm (.039-.098 in.) 36 1.42 optional illumination 2.1 3.1 1.2 load 2.2 load 3.2 load min. 1.5 min .059 .5 < R0 20 < .0 34 +0.2 1.34 +.008 +0.3 +.012 26.1+0.2 29.5 1.16 ±0.1 ±.004 line 1.1 1.03+.008 R3 18 .1 flat head screw M3.5x5 -MS ISO 1580 (H7) tightening torque max. 0.8 Nm Panel cut-out Edges of working parts: DIN 6784 This is a metric design and millimeter dimensions take precedence ( mm ) inch 1815 www.e-t-a.de 3 Thermal Overcurrent Circuit Breaker 3130 Typical time/current characteristics Installation drawing 3130-F1... Multipole types: all poles symmetrically loaded. With single pole overload, thermal tripping will be at approx. 1.54 x IN with 2-pole devices and at approx. 1.68 x IN with 3-pole devices. When installing the circuit breaker apply pressure on bezel only. operating area 0.1…2 A I.3 LINE I.I I.2 -30 °C -22 °F Trip time in seconds 32 1.26 1000 1 10 .394 +23 °C +73.4 °F 25 .984 +60 °C +140 °F 10000 100 5 .197 8 .315 10 20 .787 mounting area 7 .276 7 .276 Accessories 3130-F130-... 1 0.1 1 2 4 6 8 10 … times rated current 20 Splash cover, transparent, for 3-pole version X 221 258 01 (IP54), comprising bezel Y 306 109 01 and transparent cover Y 306 108 01 40 2.5…20 A 1-pole 2.5…16 A 2- and 3-pole 41.5 1.63 +60 °C +140 °F 10000 +23 °C +73.4 °F -30 °C -22 °F 5 50 1.97 12 .472 100 .197 36.5 1.44 ø11 .433 10 55 2.17 ø4.4 .173 Trip time in seconds 1000 ø8 .315 1 0.1 1 2 4 6 8 10 … times rated current 20 50 1.97 40 The time/current characteristic curve depends on the ambient temperature prevailing. In order to eliminate nuisance tripping, please multiply the circuit breaker current ratings by the derating factor shown below. See also section Technical information. Ambient temperature Derating factor °F °C -22 -30 -4 -20 +14 -10 +32 0 +73.4 +23 +104 +40 +122 +50 +140 +60 0.8 0.84 0.88 0.92 1 1.08 1.14 1.23 This is a metric design and millimeter dimensions take precedence ( mm ) inch All dimensions without tolerances are for reference only. In the interest of improved design, performance and cost effectiveness the right to make changes in these specifications without notice is reserved.Product markings may not be exactly as the ordering codes. Errors and omissions excepted. 4 www.e-t-a.de 1815 Appliance Inlet Module X3130 for 2-pole circuit breaker 3130-FA.A Description Technical data Typical applications Electrical medical apparatus, laboratory equipment, professional audio equipment and office machines. Ordering information Number of poles L, N + ground Cable cross section max. 1.5 mm2 Degree of protection Mounting method Class I screw-type mounting (front or rear) Terminal design blade terminals DIN 46244 A6.3 x 0.8 Housing material thermoplastics, black UL94V-0 Appliance inlet Switch C14 according to IEC/EN 60320-1, UL 498 circuit breaker type 3130, 2-pole 1 Dimensions Circuit breaker 3130 (2-pole) 72 LINE I.I 04 00 01 - M Ordering example Ambient temperature 10 A (IEC) 15 A (UL/CSA) -25°C ... 70°C I.2 X3130 - A AC 240 V Rated current I.3 Type No. X3130 Appliance inlet module for circuit breaker type 3130-FA.A Module A appliance inlet C14 Design 04 screw-type mounting Accessories 00 without Version 00 not wired; mounting position 3130: I to connector 01 not wired; mounting position 3130: 0 to connector (standard) Delivery condition M module supplied with circuit breaker FA.A Rated voltage 82 The appliance inlet module X3130 with double pole circuit breaker 3130-FA.A combines three functions within a single component: A C14 appliance inlet and rocker switch with resettable overcurrent protection; screw mounting from the front or the rear. Approvals ENEC, UL, CSA, CCC 24 ø 3.3 36.5 40.2 Mounting hole X3130 31.6 ± 0.1 1.24 M3/Ø 3.3 Ø.130 63.6 ± 0.15 2.50 72 ± 0.2 2.83 1815 www.e-t-a.de 5
3130-FA2A-P7T1-W01Q-3A-A040001M 价格&库存

很抱歉,暂时无法提供与“3130-FA2A-P7T1-W01Q-3A-A040001M”相匹配的价格&库存,您可以联系我们找货

免费人工找货