POWER QUALITY ANALYZERS, METERS & LOGGERS
Three-Phase Power Quality Analyzer
Special
product
features
▼
M E MO
'
END
RD
S
AP
N
SIE T
T R
TR
ING
R
E T AN
SA
RA
A
YE R
WA
Memory capacity of
2GB of trend data
storage: up to 50 screen
shots, 300 captured
transients/inrush and
10,000 alarm events
RECO
3
TY
2 GB
PowerPad® Model 8335
RY
''
RRAN
(upon registering)
FET Y
TIN G
Four voltage and four current inputs
Specifications
MODEL
electrical
8335
Sampling Frequency
Data Storage
256 samples/cycle
2GB SD Card for trend recording;
Additional separate 12.5MB partitioned for
snapshots, transients, Inrush & alarms
Phase-to-Phase: 2000V
Phase-to-Neutral: 1000V
Voltage Ratio: up to 500kV
MN Clamp: 0 to 6A/120A or 0 to 240A
SR Clamp: 0 to 1200A
MR Clamp: 0 to 1000Aac, 0 to 1400Adc
MiniFlex®: 10 to 1000A
AmpFlex®: 10 to 6500A(1)
Current Ratio: 10mA to 50kA
40 to 69Hz
kW, kVAR, kVA, PF, DPF, kWh, kVARh,
kVAh, K-Factor, Flicker
1st to 50th, Direction, Sequence
9.6V NiMH rechargeable battery pack (included)
External AC supply: 110/230VAC ±10% (50/60Hz)
≥8 hours with display on; ≤35 hours with display off
(record mode)
Voltage (TRMS)
Current (TRMS)
Frequency (Hz)
Other Measurements
Harmonics
Power Source
Battery Life
Mechanical
Communication Port
Display
Dimensions
Weight
Safety Rating
Optically isolated USB
¼ VGA (320 x 240) color LCD display with adjustable
brightness & contrast
9.8 x 7.8 x 2.6" (250 x 200 x 67mm)
4.3 lbs (1.95kg)
EN 61010, 600V CAT IV(2), 1000V CAT III,
Pollution Degree 2
Crest factor at 6500 = 1
(1)
product includes
8335 Kit
Five 10 ft black voltage leads,
five black alligator clips, twelve
color-coded rings, USB cable,
NiMH battery, 110/240V power
adapter with US power cord,
DataView® software, large
classic tool bag, soft carrying
pouch and user manual.
(See page 25 for optional
current probes)
24
www.aemc.com
When used with SR193 or AmpFlex® probes.
600V CAT III with MN193 or MR193 probes.
(2)
FEATURES
• Measurement of TRMS voltages up to 1000Vrms AC/DC
for two-, three-, four- or five-wire systems
• Measurement of TRMS currents up to 6500Arms
(sensor dependent)
• Color-coded input ID markers included
• Direct measurement of neutral current & voltage
• Frequency measurement (40 to 69Hz systems)
• Record and display trend data as fast as once
per second for one month for up to 25 variables
• Transient detection on all V and I inputs (up to 210)
• Selectable PT and CT ratios
•
Inrush current measurement
• Calculation of Crest Factors for V and A
• Calculation of the K-Factor for transformers
• Calculation of short-term flicker
• Calculation of the Three-Phase voltage unbalance
• H
armonic measurements (referenced to the fundamental
or RMS value) for voltage, current or power, up to 50th
harmonic
• Displays of harmonic sequencing and
direction and calculation of overall harmonics
• Real-time display of Phasor diagrams
including values and phase angles
• Monitors the average value of any parameter,
calculated for a period from 1 sec to 2 hrs
• Measurement of active, reactive and apparent power per
phase and their respective sum total
• Calculation of power factor, displacement power factor
and tangent factor
• Recording, time stamping and characterization of
disturbance (swells, sags and interruptions, exceedence
of power and harmonic thresholds)
• 2GB internal Trend Recording memory; Alarm, Photo
and Transient Inrush memories are separate
• Measurement of energy VAh, VARh & Wh
• The Max and Min RMS measurements are
calculated every half-period
• Includes FREE DataView ® software for data storage,
real-time display, analysis and report generation
• 65μs/sample trend recording
Technical Assistance (800) 343-1391
C
PowerPad® Model 8335
Large Color Functional Displays
Configuration
Transient Mode
Power and Energy Mode
Phasor Diagram
Recording Mode
Harmonics Mode
Take a look at
Model 8335's
key features ►
and functionality
Catalog No.
2136.20
2136.21
2136.22
2136.23
2136.24
2136.25
2136.26
2136.27
2136.28
2133.73
2140.15
2140.17
2140.19
2140.28
2140.32
2140.33
2140.34
2140.35
2140.36
2140.43
2140.44
2140.45
2140.46
2140.48
Description
PowerPad® Model 8335 (no probes)
PowerPad® Model 8335 w/4 MN93-BK (200A)
PowerPad® Model 8335 w/4 SR193-BK (1200A)
PowerPad® Model 8335 w/4 24" AmpFlex® 193-24-BK (6500A)
PowerPad® Model 8335 w/4 36" AmpFlex® 193-36-BK (6500A)
PowerPad® Model 8335 w/4 MR193-BK (1000Aac/1400Adc)
PowerPad® Model 8335 w/4 MN193-BK (5A/100A)
PowerPad® Model 8335 w/4 MA193-10-BK (1000A)
PowerPad® Model 8335 w/3 193-24-BK & 1 MN193-BK
Extra Large Classic Tool Bag
Replacement – Soft Carrying Pouch
5A Adapter Box (special order only)
Replacement – Battery 9.6V NiMH
AC Current Probe Model MR193-BK (1000Aac/1400Adc)
AC Current Probe Model MN93-BK (200A)
AC Current Probe Model SR193-BK (1200A)
AmpFlex® Sensor 24" Model 193-24-BK (6500A)
AmpFlex® Sensor 36" Model 193-36-BK (6500A)
AC Current Probe Model MN193-BK (5A/100A)
Replacement – Set of 5, 10 ft (3m) black leads w/5 black alligator clips
Lead, 1 10 ft (3m) black lead w/black alligator clip
Replacement – Set of 12, Color-coded Input ID Markers
Replacement – 5 ft USB Cable
One MiniFlex® Sensor 10" Model MA193-10-BK (1000A)
Technical Assistance (800) 343-1391
www.aemc.com
25
POWER QUALITY ANALYZERS, METERS & LOGGERS
DATAVIEW®
Three-Phase Power Quality Analyzer
Software
Data Analysis and Reporting Software for Power Quality Meters
Configure all functions of the PowerPad ®
• Display and analyze real-time data on your PC
• Configure all PowerPad ®functions and parameters from your PC
• Customize views, templates and reports to your exact needs
• Create and store a complete library of configurations that can be
uploaded to the PowerPad ® as needed
• Zoom in and out and pan through sections of the graph to
analyze the data
• Download, display and analyze recorded data
• Display waveforms, trend graphs, harmonic spectrums,
text summaries, transients, event logs and stored alarms
• Print reports using standard or custom templates you design
• Free updates are available on our website www.aemc.com
DataView ® software provides a convenient way to configure and display power quality measurements from your
computer. Through the use of clear and easy-to-use tabbed dialog boxes, all PowerPad ® functions can be configured
and tests can be initiated. Results can be displayed in real-time and stored in your PC. Reports may be printed along
with the operator’s comments and analysis.
Technical Assistance (800) 343-1391
www.aemc.com
21