0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
2140.19

2140.19

  • 厂商:

    AEMC

  • 封装:

  • 描述:

    AEMC - 2140.19 - REPLACEMENT BATTERY, MODELS 3945/3945-B, 8335

  • 数据手册
  • 价格&库存
2140.19 数据手册
POWER QUALITY ANALYZERS, METERS & LOGGERS Three-Phase Power Quality Analyzer Special product features ▼ M E MO ' END RD S AP N SIE T T R TR ING R E T AN SA RA A YE R WA Memory capacity of 2GB of trend data storage: up to 50 screen shots, 300 captured transients/inrush and 10,000 alarm events RECO 3 TY 2 GB PowerPad® Model 8335 RY '' RRAN (upon registering) FET Y TIN G Four voltage and four current inputs Specifications MODEL electrical 8335 Sampling Frequency Data Storage 256 samples/cycle 2GB SD Card for trend recording; Additional separate 12.5MB partitioned for snapshots, transients, Inrush & alarms Phase-to-Phase: 2000V Phase-to-Neutral: 1000V Voltage Ratio: up to 500kV MN Clamp: 0 to 6A/120A or 0 to 240A SR Clamp: 0 to 1200A MR Clamp: 0 to 1000Aac, 0 to 1400Adc MiniFlex®: 10 to 1000A AmpFlex®: 10 to 6500A(1) Current Ratio: 10mA to 50kA 40 to 69Hz kW, kVAR, kVA, PF, DPF, kWh, kVARh, kVAh, K-Factor, Flicker 1st to 50th, Direction, Sequence 9.6V NiMH rechargeable battery pack (included) External AC supply: 110/230VAC ±10% (50/60Hz) ≥8 hours with display on; ≤35 hours with display off (record mode) Voltage (TRMS) Current (TRMS) Frequency (Hz) Other Measurements Harmonics Power Source Battery Life Mechanical Communication Port Display Dimensions Weight Safety Rating Optically isolated USB ¼ VGA (320 x 240) color LCD display with adjustable brightness & contrast 9.8 x 7.8 x 2.6" (250 x 200 x 67mm) 4.3 lbs (1.95kg) EN 61010, 600V CAT IV(2), 1000V CAT III, Pollution Degree 2 Crest factor at 6500 = 1 (1) product includes 8335 Kit Five 10 ft black voltage leads, five black alligator clips, twelve color-coded rings, USB cable, NiMH battery, 110/240V power adapter with US power cord, DataView® software, large classic tool bag, soft carrying pouch and user manual. (See page 25 for optional current probes) 24 www.aemc.com When used with SR193 or AmpFlex® probes. 600V CAT III with MN193 or MR193 probes. (2) FEATURES • Measurement of TRMS voltages up to 1000Vrms AC/DC for two-, three-, four- or five-wire systems • Measurement of TRMS currents up to 6500Arms (sensor dependent) • Color-coded input ID markers included • Direct measurement of neutral current & voltage • Frequency measurement (40 to 69Hz systems) • Record and display trend data as fast as once per second for one month for up to 25 variables • Transient detection on all V and I inputs (up to 210) • Selectable PT and CT ratios •  Inrush current measurement • Calculation of Crest Factors for V and A • Calculation of the K-Factor for transformers • Calculation of short-term flicker • Calculation of the Three-Phase voltage unbalance • H  armonic measurements (referenced to the fundamental or RMS value) for voltage, current or power, up to 50th harmonic • Displays of harmonic sequencing and direction and calculation of overall harmonics • Real-time display of Phasor diagrams including values and phase angles • Monitors the average value of any parameter, calculated for a period from 1 sec to 2 hrs • Measurement of active, reactive and apparent power per phase and their respective sum total • Calculation of power factor, displacement power factor and tangent factor • Recording, time stamping and characterization of disturbance (swells, sags and interruptions, exceedence of power and harmonic thresholds) • 2GB internal Trend Recording memory; Alarm, Photo and Transient Inrush memories are separate • Measurement of energy VAh, VARh & Wh • The Max and Min RMS measurements are calculated every half-period • Includes FREE DataView ® software for data storage, real-time display, analysis and report generation • 65μs/sample trend recording Technical Assistance (800) 343-1391 C PowerPad® Model 8335 Large Color Functional Displays Configuration Transient Mode Power and Energy Mode Phasor Diagram Recording Mode Harmonics Mode Take a look at Model 8335's key features ► and functionality Catalog No. 2136.20 2136.21 2136.22 2136.23 2136.24 2136.25 2136.26 2136.27 2136.28 2133.73 2140.15 2140.17 2140.19 2140.28 2140.32 2140.33 2140.34 2140.35 2140.36 2140.43 2140.44 2140.45 2140.46 2140.48 Description PowerPad® Model 8335 (no probes) PowerPad® Model 8335 w/4 MN93-BK (200A) PowerPad® Model 8335 w/4 SR193-BK (1200A) PowerPad® Model 8335 w/4 24" AmpFlex® 193-24-BK (6500A) PowerPad® Model 8335 w/4 36" AmpFlex® 193-36-BK (6500A) PowerPad® Model 8335 w/4 MR193-BK (1000Aac/1400Adc) PowerPad® Model 8335 w/4 MN193-BK (5A/100A) PowerPad® Model 8335 w/4 MA193-10-BK (1000A) PowerPad® Model 8335 w/3 193-24-BK & 1 MN193-BK Extra Large Classic Tool Bag Replacement – Soft Carrying Pouch 5A Adapter Box (special order only) Replacement – Battery 9.6V NiMH AC Current Probe Model MR193-BK (1000Aac/1400Adc) AC Current Probe Model MN93-BK (200A) AC Current Probe Model SR193-BK (1200A) AmpFlex® Sensor 24" Model 193-24-BK (6500A) AmpFlex® Sensor 36" Model 193-36-BK (6500A) AC Current Probe Model MN193-BK (5A/100A) Replacement – Set of 5, 10 ft (3m) black leads w/5 black alligator clips Lead, 1 10 ft (3m) black lead w/black alligator clip Replacement – Set of 12, Color-coded Input ID Markers Replacement – 5 ft USB Cable One MiniFlex® Sensor 10" Model MA193-10-BK (1000A) Technical Assistance (800) 343-1391 www.aemc.com 25 POWER QUALITY ANALYZERS, METERS & LOGGERS DATAVIEW® Three-Phase Power Quality Analyzer Software Data Analysis and Reporting Software for Power Quality Meters Configure all functions of the PowerPad ® • Display and analyze real-time data on your PC • Configure all PowerPad ®­functions and ­parameters from your PC • Customize views, templates and reports to your exact needs • Create and store a complete library of configurations that can be uploaded to the PowerPad ® as needed • Zoom in and out and pan through sections of the graph to ­analyze the data • Download, display and analyze recorded data • Display waveforms, trend graphs, harmonic spectrums, text summaries, transients, event logs and stored alarms • Print reports using standard or custom ­templates you design • Free updates are available on our website www.aemc.com DataView ® software provides a convenient way to configure and display power quality measurements from your computer. Through the use of clear and easy-to-use tabbed dialog boxes, all PowerPad ® ­functions can be configured and tests can be i­nitiated. Results can be displayed in real-time and stored in your PC. Reports may be printed along with the operator’s comments and analysis. Technical Assistance (800) 343-1391 www.aemc.com 21
2140.19 价格&库存

很抱歉,暂时无法提供与“2140.19”相匹配的价格&库存,您可以联系我们找货

免费人工找货