0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
4050300873664

4050300873664

  • 厂商:

    AMSOSRAM(艾迈斯半导体)

  • 封装:

  • 描述:

    OSRAM - 4050300873664 - Lamp, Powerball, Metal Halide, 72 W, 100 VAC Input

  • 数据手册
  • 价格&库存
4050300873664 数据手册
www.osram.com POWERBALL® HCI® Technical Information POWERBALL® HCI®-TF, TC 1 2 HCI-TF w 20 W Ne 830 WDL PB UVS, PB MT/UB-20/30/1BH/E-GU6.5-13/57 20 90 3.6/5 0.22 1700 85 830 WDL 3000 > 80 >8 21 < 0.4 G8.5 15 81 52 universal 12000 400 280 ECG HCI-TC 20/830 WDL PB 4008321052216 12 2 1/2 90 90 Luminous flux in % Survival rate in % 100 80 70 60 0 2000 4000 6000 Hours burned 8000 10000 80 70 60 50 12000 0 90 90 Luminous flux in % Survival rate in % 100 80 70 60 0 2000 4000 6000 Hours burned 8000 10000 12000 10000 12000 0 2000 4000 6000 Hours burned 8000 10000 12000 8000 10000 12000 Luminous flux behaviour HCI-TC 90 90 Luminous flux in % Survival rate in % 2 8000 60 50 100 80 70 60 2000 6000 Hours burned 70 Survival rate HCI-TC 0 4000 80 100 50 2000 Luminous flux behaviour HCI-TC 20 W Survival rate HCI-TC 20 W 100 50 HCI-TC 35 W 942 NDL PB UVS, PB MT/UB-35/42/1AH-G8.5-15/81 37 90 3.6/5 0.5 3200 86 942 NDL 4200 90 > 21 < 0.4 G8.5 15 81 52 universal 12000 450 300 6 HCI-TC 35/942 NDL PB 4050300873725 12 2 1/2 Luminous flux behaviour HCI-TF Survival rate HCI-TF 100 50 HCI-TC 35 W 830 WDL PB UVS, PB MT/UB-35/30/1BH-G8.5-15/81 37 90 3.6/5 0.5 3400 92 830 WDL 3000 82 > 21 < 0.4 G8.5 15 81 52 universal 12000 450 300 6 HCI-TC 35/830 WDL PB 4050300873763 12 2 1/2 4000 6000 Hours burned 8000 10000 12000 80 70 60 50 0 2000 4000 6000 Hours burned POWERBALL® HCI®-TC 1 HCI-TC 70 W 830 WDL PB UVS, PB MT/UB-70/30/1BH-G8.5-15/81 72 90 3.6/5 0.96 6900 96 830 WDL 3000 88 > 21 < 0.4 G8.5 15 81 52 universal 12000 550 300 12 HCI-TC 70/830 WDL PB 4008321907639 12 1 1/2 Type ILCOS Lamp wattage Lamp voltage Ignition voltage min./max. Lamp current Nominal luminous flux Luminous efficacy Light colour/Colour appearance Colour temperature Colour rendering index NIOSH Skin ACGIH UV output Base Diameter d Length max. l LCL a Burning position Average lamp life Max. perm. outer bulb temp. Max. perm. base edge temp. PF corr. cap. at 50 Hz Lamp reference W V kVs A lm lm/W K Ra h mW/m2 · 1000 lx mm mm mm h °C °C µF EAN Standard pack Figure Circuit (see page 26) Qty No. Fig. no. HCI-TC w 70 W Ne 942 NDL PB UVS, PB in development 72 91 3.6/5 0.96 6600 92 942 NDL 4200 94 >8 22 < 0.37 G8.5 15 81 52 universal 12000 550 300 12 HCI-TC 70/942 NDL 4050300873794 12 1 1/2 Luminous flux behaviour HCI-TC Survival rate HCI-TC 100 50 HCI-TC 70 W 830 WDL UVS MT/UB-70/30/1BH-G8.5-15/81 72 90 3.6/4.5 0.96 6600 92 830 WDL 3000 81 > 24 < 0.35 G8.5 15 81 52 universal 12000 550 300 12 HCI-TC 70/830 WDL 4050300873831 12 1 1/2 4000 6000 Hours burned 8000 10000 12000 80 70 60 50 0 2000 4000 6000 Hours burned 8000 10000 12000 3 POWERBALL® HCI®-T 1 HCI-T 35 W 830 WDL PB UVS, PB MT/UB-35/30/1BH-G12-19/100 W 37 V 90 kVs 3.6/5 A 0.5 lm 3400 lm/W 92 830 WDL K 3000 Ra 84 h > 21 mW/m2 · 1000 lx < 0.4 G12 mm 19 mm 100 mm 56 universal h 12000 °C 450 °C 280 µF 6 HCI-T 35/830 WDL PB 4008321005625 Qty 12 No. 1 Fig. no. 1/2 Type ILCOS Lamp wattage Lamp voltage Ignition voltage min./max. Lamp current Nominal luminous flux Luminous efficacy Light colour/Colour appearance Colour temperature Colour rendering index NIOSH Skin ACGIH UV output Base Diameter d Length max. l LCL a Burning position Average lamp life Max. perm. outer bulb temp. Max. perm. base edge temp. PF corr. cap. at 50 Hz Lamp reference EAN Standard pack Figure Circuit (see page 26) HCI-T 35 W 942 NDL PB UVS, PB MT/UB-35/42/1AH-G12-19/100 37 90 3.6/5 0.5 3300 89 942 NDL 4200 90 > 21 < 0.4 G12 19 100 56 universal 12000 450 280 6 HCI-T 35/942 NDL PB 4050300873480 12 1 1/2 HCI-T 70 W 830 WDL PB UVS, PB MT/UB-70/30/1BH-G12-19/100 72 100 3.6/5 0.96 7000 97 830 WDL 3000 87 > 47 < 0.18 G12 19 100 56 universal 12000 500 280 12 HCI-T 70/830 WDL PB 4050300873664 12 1 1/2 100 90 90 80 70 60 50 4 0 2000 HCI-T w 100 W Ne 830 WDL PB UVS, PB MT/UB-100/30/1BH-G12-19/100 100 100 3.6/5 1.2 9500 95 830 WDL 3000 86 >8 27 < 0.32 G12 19 100 56 universal 12000 500 280 12 HCI-T 70/942 NDL PB 4050300873626 12 1 1/2 4000 6000 Hours burned 8000 10000 12000 80 70 60 50 0 2000 4000 6000 Hours burned 8000 10000 12000 POWERBALL® HCI®-T, TM 1 2 HCI-T w 100 W Ne 942 NDL PB UVS, PB MT/UB-100/42/1AH-G12-19/100 W 100 V 100 kVs 3.6/5 A 1.2 lm 9300 lm/W 93 942 NDL K 4200 Ra > 90 h >8 mW/m2 · 1000 lx < 2 G12 mm 19 mm 100 mm 56 universal h 12000 °C 500 °C 280 µF 16 HCI-T 100/942 NDL PB 4008321907677 Qty 12 No. 1 Fig. no. 1/2 Type ILCOS Lamp wattage Lamp voltage Ignition voltage min./max. Lamp current Nominal luminous flux Luminous efficacy Light colour/Colour appearance Colour temperature Colour rendering index NIOSH Skin ACGIH UV output Base Diameter d Length max. l LCL a Burning position Average lamp life Max. perm. outer bulb temp. Max. perm. base edge temp. PF corr. cap. at 50 Hz Lamp reference EAN Standard pack Figure Circuit (see page 26) HCI-T 150 W 830 WDL PB UVS, PB MT/UB-150/30/1BH-G12-25/105 145 100 3.6/5 1.8 15500 107 830 WDL 3000 86 > 50 < 0.06 G12 25 105 56 universal 12000 550 280 20 HCI-T 150/830 WDL PB 4050300873435 12 1 1/2 HCI-T 150 W 942 NDL PB UVS, PB MT/UB-150/42/1AH-G12-25/105 145 92 3.6/5 1.8 14500 100 942 NDL 4200 96 > 50 < 0.12 G12 25 105 56 universal 12000 550 280 20 HCI-T 150/942 NDL PB 4050300873336 12 1 1/2 100 90 90 80 70 60 50 0 2000 4000 6000 Hours burned 8000 10000 80 70 60 50 12000 0 90 90 Luminous flux in % Survival rate in % 100 80 70 60 0 2000 2000 4000 6000 Hours burned 8000 10000 12000 8000 10000 12000 Luminous flux behaviour HCI-TM Survival rate HCI-TM 100 50 HCI-TM w 250 W Ne 942 NDL PB UVS, PB MT/UB-250/42/1AH-G22-34/175 249 98 3.6/5 3.0 25000 100 942 NDL 4200 98 >8 300 < 0.028 G22 28 175 90 universal 12000 580 280 32 HCI-TM 250/830 WDL PB 4050300977263 10 2 1 4000 6000 Hours burned 8000 10000 12000 80 70 60 50 0 2000 4000 6000 Hours burned 5 POWERBALL® HCI®-T, TC, Shoplight 1 2 HCI-T w 35 W Ne 930 WDL PB UVS, PB, Shoplight MT/UB-35/30/1AH-G12-19/100 39 92 3.6/5 0.5 2800 79 930 WDL 3000 92 >8 21 < 0.4 G12 19 100 56 universal 12000 550 300 12 HCI-T 70/930 WDL PB Shop 4050300983134 12 1 1/2 90 90 6 Luminous flux in % Survival rate in % 100 80 70 60 0 2000 4000 HCI-TC 70 W 930 WDL PB UVS, PB, Shoplight MT/UB-70/30/1AH-G8.5-15/81 73 95 3.6/5 0.96 6300 86 930 WDL 3000 95 > 24 < 0.35 G8.5 15 81 52 universal 12000 550 300 12 HCI-TC 70/930 WDL PB Shop 4050300983110 12 2 1/2 Luminous flux behaviour Shoplight Survival rate Shoplight 100 50 HCI-TC w 35 W Ne 930 WDL PB UVS, PB, Shoplight MT/UB-35/30/1AH-G8.5-15/81 37 92 3.6/5 0.5 2800 79 930 WDL 3000 92 >8 50 < 0.04 E40 46 226 150 universal 12000 500 250 32 HCI-T 250/830 WDL PB 4050300636849 12 1 1 Type ILCOS Lamp wattage Lamp voltage Ignition voltage min./max. Lamp current Nominal luminous flux Luminous efficacy Light colour/Colour appearance Colour temperature Colour rendering index NIOSH Skin ACGIH UV output Base Diameter d Length max. l LCL a Burning position Average lamp life Max. perm. outer bulb temp. Max. perm. base edge temp. PF corr. cap. at 50 Hz Lamp reference W V kVs A lm lm/W K Ra h mW/m2 · 1000 lx mm mm mm h °C °C µF EAN Standard pack Figure Circuit (see page 26) Qty No. Fig. no. HCI-T w 250 W Ne 942 NDL PB UVS, PB MT/UB-250/42/1AH-E40-46/226 250 100 3.6/5 2.8 25000 100 942 NDL 4200 96 >8 50 < 0.04 E40 46 204 132 universal 15000 400 210 20 HCI-TT 150/830 WDL PB 4050300784144 12 1 1 Luminous flux behaviour HCI-T 250 W 100 Luminous flux in % Survival rate in % Survival rate HCI-T 250 W HCI-TT 70 W 830 WDL PB UVS, PB MT/UB-70/30/1BH-E27-30/150 74 90 1.8/5 0.92 7000 95 830 WDL 3000 86 > 47 < 0.18 E27 30 150 102 universal 15000 350 210 12 HCI-TT 70/830 WDL PB 4050300784120 12 1 1 4000 6000 Hours burned 8000 10000 12000 80 70 60 50 0 2000 4000 6000 Hours burned 7 POWERBALL® HCI®-T/P 1 HCI-T/P 70 W 830 WDL PB clear UVS, PB MTS/UB-70/30/ 1B-H-E27-32/ 125 W 73 V 90 kVs 3.6/5 A 0.98 lm 6500 lm/W 89 830 WDL K 3000 Ra > 80 h > 47 2 mW/m · 1000 lx < 0.18 E27 mm 32 mm 125 mm 89 universal h 12000 °C 330 °C 190 µF 12 HCI-T/P 70/830 WDL PB clear 4008321907714 Qty 12 No. 1 Fig. no. 1/2 New Type ILCOS Lamp wattage Lamp voltage Ignition voltage min./max. Lamp current Nominal luminous flux Luminous efficacy Light colour/Colour appearance Colour temperature Colour rendering index NIOSH Skin ACGIH UV output Base Diameter d Length max. l LCL a Burning position Average lamp life Max. perm. outer bulb temp. Max. perm. base edge temp. PF corr. cap. at 50 Hz Lamp reference EAN Standard pack Figure Circuit (see page 26) HCI-T/P 70 W 830 WDL PB coated UVS, PB MTS coated/ UB-70/30/1BH-E27-32/125 73 90 3.6/5 0.98 6400 88 830 WDL 3000 > 80 > 47 < 0.18 E27 32 125 89 universal 12000 330 190 12 HCI-T/P 70/830 WDL PB coated 4008321907721 12 1 1/2 HCI-T/P 70 W 942 NDL PB clear UVS, PB MTS/UB-70/42/ 1A-H-E27-32/ 125 73 90 3.6/5 0.98 6100 84 942 NDL 4200 > 90 >8 80 >8 80 >8 90 >8 90 h >8 2 mW/m · 1000 lx < 2 E27 mm 40 mm 140 mm 89 universal h 12000 °C 330 °C 190 µF 16 HCI-T/P 100/942 NDL PB clear 4008321907776 Qty 12 No. 1 Fig. no. 1/2 New Type ILCOS Lamp wattage Lamp voltage Ignition voltage min./max. Lamp current Nominal luminous flux Luminous efficacy Light colour/Colour appearance Colour temperature Colour rendering index NIOSH Skin ACGIH UV output Base Diameter d Length max. l LCL a Burning position Average lamp life Max. perm. outer bulb temp. Max. perm. base edge temp. PF corr. cap. at 50 Hz Lamp reference EAN Standard pack Figure Circuit (see page 26) HCI-T/P 100 W 942 NDL PB coated UVS, PB MTS coated/ UB-100/42/1AH-E27-40/140 100 95 3.6/5 1.2 8300 83 942 NDL 4200 > 90 >8 80 > 50 < 0.06 E27 40 140 89 universal 12000 330 190 20 HCI-T/P 150/830 WDL PB clear 4008321907790 12 1 1/2 90 90 Luminous flux in % Survival rate in % 100 80 70 60 0 2000 HCI-T/P 150 W 942 NDL PB clear UVS, PB MTS/UB-150/42/ 1A-H-E27-40/ 140 145 95 3.6/5 1.8 14000 97 942 NDL 4200 > 90 > 50 < 0.12 E27 40 140 89 universal 12000 330 190 20 HCI-T/P 150/942 NDL PB clear 4008321907813 12 1 1/2 HCI-T/P 150 W 942 NDL PB coated UVS, PB MTS coated/ UB-150/42/1AH-E27-40/140 145 95 3.6/5 1.8 13300 92 942 NDL 4200 > 90 > 50 < 0.12 E27 40 140 89 universal 12000 330 190 20 HCI-T/P 150/942 NDL PB coated 4008321907820 12 1 1/2 Luminous flux behaviour HCI-T/P Survival rate HCI-T/P 100 50 HCI-T/P 150 W 830 WDL PB coated UVS, PB MTS coated/ UB-150/30/1BH-E27-40/140 145 95 3.6/5 1.8 14000 97 830 WDL 3000 > 80 > 50 < 0.06 E27 40 140 89 universal 12000 330 190 20 HCI-T/P 150/830 WDL PB coated 4008321907806 12 1 1/2 4000 6000 Hours burned 8000 10000 12000 80 70 60 50 0 2000 4000 6000 Hours burned 8000 10000 12000 9 POWERBALL® HCI®-TS 1 HCI-TS 70 W 830 WDL PB UVS, PB MD/UB-70/30/1BH-RX7s-21/114.2/P45 72 95 3.6/4.5 0.95 6900 96 830 WDL 3000 88 > 18 < 0.45 RX7s 21 114.2 57 p 45 12000 500 280 12 HCI-TS 70/830 WDL PB 4050300784069 12 1 1/2 Type ILCOS Lamp wattage Lamp voltage Ignition voltage min./max. Lamp current Nominal luminous flux Luminous efficacy Light colour/Colour appearance Colour temperature Colour rendering index NIOSH Skin ACGIH UV output Base Diameter d Length max. l LCL a Burning position Average lamp life Max. perm. outer bulb temp. Max. perm. base edge temp. PF corr. cap. at 50 Hz Lamp reference W V kVs A lm lm/W K Ra h mW/m2 · 1000 lx mm mm mm h °C °C µF EAN Standard pack Figure Circuit (see page 26) Qty No. Fig. no. HCI-TS 70 W 942 NDL PB UVS, PB MD/UB-70/42/1AH-RX7s-21/114.2/P45 74 94 3.6/5 0.98 6700 91 942 NDL 4200 95 > 29.7 < 0.28 RX7s 21 114.2 57 p 45 12000 500 280 12 HCI-TS 70/942 NDL PB 4050300784106 12 1 1/2 90 90 10 Luminous flux in % Survival rate in % 100 80 70 60 0 2000 HCI-TS 150 W 942 NDL PB UVS, PB MD/UB-150/42/1AH-RX7s24-24/132/P45 144 96 3.6/5 1.8 14200 99 942 NDL 4200 97 > 26 < 0.32 RX7s-24 24 132 66 p 45 12000 650 280 20 HCI-TS 150/942 NDL PB 4050300784007 12 1 1/2 Luminous flux behaviour HCI-TS Survival rate HCI-TS 100 50 HCI-TS 150 W 830 WDL PB UVS, PB MD/UB-150/30/1BH-RX7s24-24/132/P45 144 100 3.6/5 1.8 14800 103 830 WDL 3000 90 > 50 < 0.4 RX7s-24 24 132 66 p 45 12000 650 280 20 HCI-TS 150/830 WDL PB 4050300783987 12 1 1/2 4000 6000 Hours burned 8000 10000 12000 80 70 60 50 0 2000 4000 6000 Hours burned 8000 10000 12000 POWERBALL® HCI®-TS, E 1 2 Type ILCOS Lamp wattage Lamp voltage Ignition voltage min./max. Lamp current Nominal luminous flux Luminous efficacy Light colour/Colour appearance Colour temperature Colour rendering index NIOSH Skin ACGIH UV output Base Diameter d Length max. l LCL a Burning position Average lamp life Max. perm. outer bulb temp. Max. perm. base edge temp. PF corr. cap. at 50 Hz Lamp reference W V kVs A lm lm/W K Ra h mW/m2 · 1000 lx mm mm mm h °C °C µF EAN Standard pack Figure Circuit (see page 26) Qty No. Fig. no. HCI-TS 250 W 830 WDL PB HCI-TS w 250 W Ne 942 NDL PB UVS, PB MD/UB-250/30/1BH-Fc2-25/163/P45 245 100 3.6/5 3.0 25000 102 830 WDL 3000 90 > 50 < 0.15 Fc2 25 163 81.5 p 45 12000 650 280 32 HCI-TS 250/830 WDL PB 4050300637730 12 1 1 UVS, PB MD/UB-250/42/1AH-Fc2-25/163/P45 245 100 3.6/5 3.0 23000 94 942 NDL 4200 > 90 >8 90 >8 50 < 0.1 E40 90 226 – universal 12000 400 250 32 HCI-E 250/830 WDL PB 4050300636825 12 2 1 4000 6000 Hours burned 8000 10000 12000 80 70 60 50 0 2000 4000 6000 Hours burned 8000 10000 12000 11 POWERBALL® HCI®-E/P 1 HCI-E/P 35 W 830 WDL PB clear UVS, PB MCS/UB-35/30/1BH-E27-54/138 39 90 3.6/5 0.5 3000 77 830 WDL 3000 > 80 > 21 < 0.4 E27 54 138 86 universal 12000 330 190 6 HCI-E/P 35/830 WDL PB clear 4008321907837 12 1 1/2 New Type ILCOS Lamp wattage Lamp voltage Ignition voltage min./max. Lamp current Nominal luminous flux Luminous efficacy Light colour/Colour appearance Colour temperature Colour rendering index NIOSH Skin ACGIH UV output Base Diameter d Length max. l LCL a Burning position Average lamp life Max. perm. outer bulb temp. Max. perm. base edge temp. PF corr. cap. at 50 Hz Lamp reference W V kVs A lm lm/W K Ra h mW/m2 · 1000 lx mm mm mm h °C °C µF EAN Standard pack Figure Circuit (see page 26) Qty No. Fig. no. HCI-E/P 35 W 830 WDL PB coated UVS, PB MES/UB-35/30/1BH-E27-54/138 39 90 3.6/5 0.5 2850 73 830 WDL 3000 > 80 > 21 < 0.4 E27 54 138 – universal 12000 330 190 6 HCI-E/P 35/830 WDL PB coated 4008321907844 12 1 1/2 90 90 12 Luminous flux in % Survival rate in % 100 80 70 60 0 2000 HCI-E/P 35 W 942 NDL PB coated UVS, PB MES/UB-35/42/1AH-E27-54/138 39 90 3.6/5 0.5 2850 73 942 NDL 4200 > 90 > 21 < 0.4 E27 54 138 – universal 12000 330 190 6 HCI-E/P 35/942 NDL PB coated 4008321907868 12 1 1/2 Luminous flux behaviour HCI-E/P Survival rate HCI-E/P 100 50 HCI-E/P 35 W 942 NDL PB clear UVS, PB MCS/UB-35/42/1AH-E27-54/138 39 90 3.6/5 0.5 3000 77 942 NDL 4200 > 90 > 21 < 0.4 E27 54 138 86 universal 12000 330 190 6 HCI-E/P 35/942 NDL PB clear 4008321907851 12 1 1/2 4000 6000 Hours burned 8000 10000 12000 80 70 60 50 0 2000 4000 6000 Hours burned 8000 10000 12000 POWERBALL® HCI®-E/P 1 HCI-E/P 70 W 830 WDL PB clear UVS, PB MCS/UB-70/30/1BH-E27-54/138 73 90 3.6/5 0.98 6500 89 830 WDL 3000 87 > 47 < 0.18 E27 54 138 86 universal 12000 330 190 12 HCI-E/P 70/830 WDL PB clear 4008321907875 12 1 1/2 Type ILCOS Lamp wattage Lamp voltage Ignition voltage min./max. Lamp current Nominal luminous flux Luminous efficacy Light colour/Colour appearance Colour temperature Colour rendering index NIOSH Skin ACGIH UV output Base Diameter d Length max. l LCL a Burning position Average lamp life Max. perm. outer bulb temp. Max. perm. base edge temp. PF corr. cap. at 50 Hz Lamp reference W V kVs A lm lm/W K Ra h mW/m2 · 1000 lx mm mm mm h °C °C µF EAN Standard pack Figure Circuit (see page 26) Qty No. Fig. no. HCI-E/P 70 W 830 WDL PB coated UVS, PB MES/UB-70/30/1BH-E27-54/138 73 90 3.6/5 0.98 6400 88 830 WDL 3000 87 > 47 < 0.18 E27 54 138 – universal 12000 330 190 12 HCI-E/P 70/830 WDL PB coated 4008321907882 12 1 1/2 90 90 Luminous flux in % Survival rate in % 100 80 70 60 0 2000 HCI-E/P 70 W 942 NDL PB coated UVS, PB MES/UB-70/42/1AH-E27-54/138 73 100 3.6/5 0.98 6000 82 942 NDL 4200 > 90 > 26 < 0.32 E27 54 138 – universal 12000 330 190 12 HCI-E/P 70/942 NDL PB coated 4008321907905 12 1 1/2 Luminous flux behaviour HCI-E/P Survival rate HCI-E/P 100 50 HCI-E/P 70 W 942 NDL PB clear UVS, PB MCS/UB-70/42/1AH-E27-54/138 73 100 3.6/5 0.98 6100 84 942 NDL 4200 > 90 > 26 < 0.32 E27 54 138 86 universal 12000 330 190 12 HCI-E/P 70/942 NDL PB clear 4008321907899 12 1 1/2 4000 6000 Hours burned 8000 10000 12000 80 70 60 50 0 2000 4000 6000 Hours burned 8000 10000 12000 13 POWERBALL® HCI®-E/P 1 HCI-E/P 100 W 830 WDL PB clear UVS, PB MCS/UB-100/30/1BH-E27-54/138 100 100 3.6/5 1.2 9000 90 830 WDL 3000 > 80 > 50 < 0.02 E27 54 138 86 universal 12000 330 190 16 HCI-E/P 100/830 WDL PB clear 4008321907912 12 1 1/2 New Type ILCOS Lamp wattage Lamp voltage Ignition voltage min./max. Lamp current Nominal luminous flux Luminous efficacy Light colour/Colour appearance Colour temperature Colour rendering index NIOSH Skin ACGIH UV output Base Diameter d Length max. l LCL a Burning position Average lamp life Max. perm. outer bulb temp. Max. perm. base edge temp. PF corr. cap. at 50 Hz Lamp reference W V kVs A lm lm/W K Ra h mW/m2 · 1000 lx mm mm mm h °C °C µF EAN Standard pack Figure Circuit (see page 26) Qty No. Fig. no. HCI-E/P 100 W 830 WDL PB coated UVS, PB MES/UB-100/30/1BH-E27-54/138 100 100 3.6/5 1.2 8500 85 830 WDL 3000 > 80 > 50 < 0.02 E27 54 138 – universal 12000 330 190 16 HCI-E/P 100/830 WDL PB coated 4008321907929 12 1 1/2 90 90 14 Luminous flux in % Survival rate in % 100 80 70 60 0 2000 HCI-E/P 100 W 942 NDL PB coated UVS, PB MES/UB-100/42/1AH-E27-54/138 100 100 3.6/5 1.2 8300 83 942 NDL 4200 > 90 >8 90 >8 50 < 0.12 E27 54 138 86 universal 12000 330 190 20 HCI-E/P 150/830 WDL PB clear 4008321907950 12 1 1/2 Type ILCOS Lamp wattage Lamp voltage Ignition voltage min./max. Lamp current Nominal luminous flux Luminous efficacy Light colour/Colour appearance Colour temperature Colour rendering index NIOSH Skin ACGIH UV output Base Diameter d Length max. l LCL a Burning position Average lamp life Max. perm. outer bulb temp. Max. perm. base edge temp. PF corr. cap. at 50 Hz Lamp reference W V kVs A lm lm/W K Ra h mW/m2 · 1000 lx mm mm mm h °C °C µF EAN Standard pack Figure Circuit (see page 26) Qty No. Fig. no. HCI-E/P 150 W 830 WDL PB coated UVS, PB MES/UB-150/30/1BH-E27-54/138 150 95 3.6/5 1.8 13300 89 830 WDL 3000 90 > 50 < 0.12 E27 54 138 – universal 12000 330 190 20 HCI-E/P 150/830 WDL PB coated 4008321907967 12 1 1/2 90 90 Luminous flux in % Survival rate in % 100 80 70 60 0 2000 HCI-E/P 150 W 942 NDL PB coated UVS, PB MES/UB-150/42/1AH-E27-54/138 150 91 3.6/5 1.8 13300 89 942 NDL 4200 > 95 > 50 < 0.17 E27 54 138 – universal 12000 330 190 20 HCI-E/P 150/942 NDL PB coated 4008321907981 12 1 1/2 Luminous flux behaviour HCI-E/P Survival rate HCI-E/P 100 50 HCI-E/P 150 W 942 NDL PB clear UVS, PB MCS/UB-150/42/1AH-E27-54/138 150 91 3.6/5 1.8 14000 93 942 NDL 4200 > 95 > 50 < 0.17 E27 54 138 86 universal 12000 330 190 20 HCI-E/P 150/942 NDL PB clear 4008321907974 12 1 1/2 4000 6000 Hours burned 8000 10000 12000 80 70 60 50 0 2000 4000 6000 Hours burned 8000 10000 12000 15 POWERBALL® HCI®-R111 d 1 HCI-R111 20 W 830 WDL PB 10D UVS, PB MRS/UB-20/30/ 1B-H-GX8.5111/95/10 W 20 V 100 kVs 3.6/5 A 0.22 cd 17000 ° 10 830 WDL K 3000 Ra > 80 h >8 2 mW/m · 1000 lx < 2 GX8.5 mm 111 mm 95 universal h 12000 µF ECG HCI-R111 20/830 WDL PB 10D 4008321907998 Qty 6 No. 1 Fig. no. 2 New Type ILCOS Lamp wattage Lamp voltage Ignition voltage min./max. Lamp current Axial luminous intensity Beam angle Light colour/Colour appearance Colour temperature Colour rendering index NIOSH Skin ACGIH UV output Base Diameter d Length max. l Burning position Average lamp life PF corr. cap. at 50 Hz Lamp reference EAN Standard pack Figure Circuit (see page 26) HCI-R111 20 W 830 WDL PB 24D UVS, PB MRS/UB-20/30/ 1B-H-GX8.5111/95/24 20 100 3.6/5 0.22 4200 24 830 WDL 3000 > 80 >8 80 >8 80 >8 80 >8 80 >8 90 h >8 2 mW/m · 1000 lx < 2 GX8.5 mm 111 mm 95 universal h 12000 µF 6 HCI-R111 35/942 NDL PB 10D 4008321908056 Qty 6 No. 1 Fig. no. 1/2 New Type ILCOS Lamp wattage Lamp voltage Ignition voltage min./max. Lamp current Axial luminous intensity Beam angle Light colour/Colour appearance Colour temperature Colour rendering index NIOSH Skin ACGIH UV output Base Diameter d Length max. l Burning position Average lamp life PF corr. cap. at 50 Hz Lamp reference EAN Standard pack Figure Circuit (see page 26) HCI-R111 35 W 942 NDL PB 24D UVS, PB MRS/UB-35/42/ 1A-H-GX8.5111/95/24 39 90 3.6/5 0.5 8500 24 942 NDL 4200 > 90 >8 90 >8 80 >8 80 >8 80 >8 80 > 22 < 0.37 E27 65 95 universal 12000 300 210 6 HCI-PAR 20 35/830 WDL PB SP 4008321908162 12 1 1/2 New Type ILCOS Lamp wattage Lamp voltage Ignition voltage min./max. Lamp current Axial luminous intensity Beam angle Light colour/Colour appearance Colour temperature Colour rendering index NIOSH Skin ACGIH UV output Base Diameter d Length max. l Burning position Average lamp life Max. perm. outer bulb temp. Max. perm. base edge temp. PF corr. cap. at 50 Hz Lamp reference W V kVs A cd ° K Ra h mW/m2 · 1000 lx mm mm h °C °C µF EAN Standard pack Figure Circuit (see page 26) Qty No. Fig. no. HCI-PAR 20 35 W 830 WDL PB FL UVS, PB MRS/UB-35/30/1BH-E27-65/95/30 39 90 3.6/4.5 0.5 5500 30 830 WDL 3000 > 80 > 22 < 0.37 E27 65 95 universal 12000 300 210 6 HCI-PAR 20 35/830 WDL PB FL 4008321908179 12 1 1/2 100 90 90 80 70 60 50 18 0 2000 4000 HCI-PAR 30 20 W 830 WDL PB FL UVS, PB MRS/UB-20/30/1BH-E27-97/125/30 20 90 3.6/4.5 0.22 4000 30 830 WDL 3000 > 80 > 22 < 0.37 E27 97 125 universal 12000 300 210 ECG HCI-PAR 30 20/830 WDL PB FL 4008321908155 6 1 2 Luminous flux behaviour HCI-PAR 100 Luminous flux in % Survival rate in % Survival rate HCI-PAR HCI-PAR 30 20 W 830 WDL PB SP UVS, PB MRS/UB-20/30/1BH-E27-97/125/10 20 90 3.6/4.5 0.22 24000 10 830 WDL 3000 > 80 > 22 < 0.37 E27 97 125 universal 12000 300 210 ECG HCI-PAR 30 20/830 WDL PB SP 4008321908148 6 1 2 6000 Hours burned 8000 10000 12000 80 70 60 50 0 2000 4000 6000 Hours burned 8000 10000 12000 POWERBALL® HCI®-PAR 30 1 HCI-PAR 30 35 W 830 WDL PB SP UVS, PB MRS/UB-35/30/ 1B-H-E2797/125/10 39 90 3.6/4.5 0.5 46000 10 830 WDL 3000 > 80 > 22 < 0.37 E27 97 125 universal 12000 300 210 6 HCI-PAR 30 35/830 WDL PB SP 4008321908209 6 1 1/2 New Type ILCOS Lamp wattage Lamp voltage Ignition voltage min./max. Lamp current Axial luminous intensity Beam angle Light colour/Colour appearance Colour temperature Colour rendering index NIOSH Skin ACGIH UV output Base Diameter d Length max. l Burning position Average lamp life Max. perm. outer bulb temp. Max. perm. base edge temp. PF corr. cap. at 50 Hz Lamp reference W V kVs A cd ° K Ra h mW/m2 · 1000 lx mm mm h °C °C µF EAN Standard pack Figure Circuit (see page 26) Qty No. Fig. no. HCI-PAR 30 35 W 830 WDL PB FL UVS, PB MRS/UB-35/30/ 1B-H-E2797/125/30 39 90 3.6/4.5 0.5 8500 30 830 WDL 3000 > 80 > 22 < 0.37 E27 97 125 universal 12000 300 210 6 HCI-PAR 30 35/830 WDL PB FL 4008321908216 6 1 1/2 100 90 90 80 70 60 50 0 2000 4000 HCI-PAR 30 70 W 830 WDL PB FL UVS, PB MRS/UB-70/30/ 1B-H-E2797/125/30 73 90 3.6/4.5 0.98 14000 30 830 WDL 3000 > 80 > 22 < 0.37 E27 97 125 universal 12000 300 210 12 HCI-PAR 30 70/830 WDL PB FL 4008321908254 6 1 1/2 HCI-PAR 30 70 W 830 WDL PB 40D UVS, PB MRS/UB-70/30/ 1B-H-E2797/125/40 73 90 3.6/4.5 0.98 12000 40 830 WDL 3000 > 80 > 22 < 0.37 E27 97 125 universal 12000 300 210 12 HCI-PAR 30 70/830 WDL PB 40 D 4008321908261 6 1 1/2 Luminous flux behaviour HCI-PAR 100 Luminous flux in % Survival rate in % Survival rate HCI-PAR HCI-PAR 30 70 W 830 WDL PB SP UVS, PB MRS/UB-70/30/ 1B-H-E2797/125/10 73 90 3.6/4.5 0.98 70000 10 830 WDL 3000 > 80 > 22 < 0.37 E27 97 125 universal 12000 300 210 12 HCI-PAR 30 70/830 WDL PB SP 4008321908247 6 1 1/2 6000 Hours burned 8000 10000 12000 80 70 60 50 0 2000 4000 6000 Hours burned 8000 10000 12000 19 POWERSTAR® HCI®-PAR 20, 30 1 HCI-PAR 20 35 W 830 WDL SP Spot 10°, UVS MRS/UB-35/30/ 1B-H-E27-65/ 95/10 W 38 V 90 kVs 3.6/4.5 A 0.5 cd 22000 ° 10 830 WDL K 3000 Ra > 80 h > 22 mW/m2 · 1000 lx < 0.37 E27 mm 65 mm 95 universal h 9000 °C 300 °C 210 µF 6 HCI-PAR 20 35/830 WDL SP 4050300941936 Qty 12 No. 1 Fig. no. 1/2 Type ILCOS Lamp wattage Lamp voltage Ignition voltage min./max. Lamp current Axial luminous intensity Beam angle Light colour/Colour appearance Colour temperature Colour rendering index NIOSH Skin ACGIH UV output Base Diameter d Length max. l Burning position Average lamp life Max. perm. outer bulb temp. Max. perm. base edge temp. PF corr. cap. at 50 Hz Lamp reference EAN Standard pack Figure Circuit (see page 26) HCI-PAR 20 35 W 830 WDL FL Flood 30°, UVS MRS/UB-35/30/ 1B-H-E27-65/ 95/30 38 90 3.6/4.5 0.5 5000 30 830 WDL 3000 > 80 > 22 < 0.37 E27 65 95 universal 9000 300 210 6 HCI-PAR 20 35/830 WDL FL 4050300941950 12 1 1/2 HCI-PAR 30 35 W 830 WDL SP Spot 10°, UVS MRS/UB-35/30/ 1B-H-E27-97/ 125/10 38 90 3.6/4.5 0.5 37000 10 830 WDL 3000 > 80 > 22 < 0.37 E27 97 125 universal 9000 300 210 6 HCI-PAR 30 35/830 WDL SP 4050300941974 6 1 1/2 100 90 90 80 70 60 50 20 0 2000 4000 HCI-PAR 30 70 W 830 WDL SP Spot 10°, UVS MRS/UB-70/30/ 1B-H-E27-97/ 125/10 73 90 3.6/4.5 0.97 55000 10 830 WDL 3000 > 80 > 22 < 0.37 E27 97 125 universal 9000 300 210 12 HCI-PAR 30 70/830 WDL SP 4050300942018 6 1 1/2 HCI-PAR 30 70 W 830 WDL FL Flood 30°, UVS MRS/UB-70/30/ 1B-H-E27-97/ 125/30 73 90 3.6/4.5 0.97 10000 30 830 WDL 3000 > 80 > 22 < 0.37 E27 97 125 universal 9000 300 210 12 HCI-PAR 30 70/830 WDL FL 4050300942032 6 1 1/2 Luminous flux behaviour HCI-PAR 100 Luminous flux in % Survival rate in % Survival rate HCI-PAR HCI-PAR 30 35 W 830 WDL FL Flood 30°, UVS MRS/UB-35/30/ 1B-H-E27-97/ 125/30 38 90 3.6/4.5 0.5 7000 30 830 WDL 3000 > 80 > 22 < 0.37 E27 97 125 universal 9000 300 210 6 HCI-PAR 30 35/830 WDL FL 4050300941998 6 1 1/2 6000 Hours burned 8000 10000 12000 80 70 60 50 0 2000 4000 6000 Hours burned 8000 10000 12000 Please note: The values and curves published in this document are for guidance only. The basic data was determined under controlled laboratory conditions for a switching cycle of 11 h on/1 h off. There may be considerable differences in actual practice. The highlighted areas around the curves represent a 90% confidence range based on our test conditions. NIOSH threshold and ACGIH UV output: The radiated energy of a lamp is indicated by the defined NIOSH curve. The NIOSH effective radiated output calculated from this is converted into permitted exposure times with defined limit values. The ACGIH UV output value correlates directly with the NIOSH value and represents the current required value for UV exposure. PF correction capacitor: The pf correction capacitors are designed so that cos  ≥ 0.9 is achieved at rated voltage. 21 Operating instructions Supply voltage: The lamps must be connected via suitable control gear. A 240 V / 50 Hz ac supply is generally required. If a different supply voltage is used (e.g. 400 V / 50 Hz) control gear with appropriate taps must be used. Operating temperatures: Only high-pressure discharge lamps with external igniters are suitable for low-temperature applications down to – 50 °C. Such applications call for special (heatable) igniters such as MZN 400 SU-LT from BAG Turgi (for lamps from 100 to 400 W). Permitted mains voltage deviation: ± 3% Sudden fluctuations in mains voltage of more than 10% may cause the lamps to go out. If the deviation from rated supply voltage (230 V or 400 V) is permanent, high-pressure discharge lamps may exhibit changes in colour or luminous flux. Lamp life may also be reduced. Power factor: CCG: Because of the series connected choke this is around 0.5 to 0.7 (without compensation) ECG: If POWERTRONIC® is used the power factor is greater than 0.96. Compensation is therefore not needed here. Control gear: Switching on: Conventional control gear: Choke, igniter and pf correction capacitor. The right igniter for the particular lamp type must be used to ensure reliable and safe ignition. Igniters must always be installed close to the lamp. The choke may be installed any distance from the lamp, provided the permissible voltage drop is not exceeded. For power supplies with a neutral conductor the choke should be connected to the live conductor. In the case of luminaires in which there are no lamps installed, the ignition equipment (igniter, ignition pulser) must be disabled when voltage is applied otherwise the igniters may produce radio interference. The chokes and pf correction capacitors generally needed for operating discharge lamps may, under certain conditions, create oscillating circuits. These circuits may then produce excessive currents and voltages, which in turn can destroy the lamps, ballasts and capacitors. Such resonance phenomena must be avoided by appropriate circuits and fuses. When high-pressure discharge lamps come to the end of their lives a rectifier effect may occur (see IEC 62035). This is not manufacturer-specific. Because of the excessive dc current components the ballasts and igniters may become overheated. High-pressure discharge lamps should therefore only be operated with control gear with thermal protection. This applies also to control gear with the option of power reduction. Suitable igniters and control gear for POWERBALL® HCI® are available from the electrical industry. 22 Full luminous flux is reached only a few minutes after the lamp is switched on. The start-up current may be up to twice the operating current depending on the control gear. (See also the graphs on p. 25) Fusing: HCI® lamps must be protected by slow acting fuses. If fuse wire is used it is sufficient for it to be rated at twice the rated current of the lamp. If automatic cutouts are used they should have characteristic “C”. If adjusted to the upper limit value of 10 x rated current there will be no triggering if fuse protection is at twice the rated lamp current. Restarting: The lamps will restart only after they have cooled down for 2 to 15 minutes. Lampholders: Because of the high voltages involved in ignition the lampholders must be designed for these high voltages. Lampholders that meet these requirements are available from appropriate manufacturers. Dimming: In principle, dimming of HCI® POWERBALL® is technically feasible, but OSRAM does not recommend it for the lamps currently available on the market, because the typical characteristics of HCI® POWERBALL® change when dimmed. The higher thermal load capacity of the round ceramic burner offers better dimming behavior in terms of luminous efficacy and color rendering compared to metal halide lamps with quartz burners or standard cylindrical ceramic burners. As before, however, dimming does lead to a change in the chromaticity coordinates. Lamps operated at dimmed settings suffer a greater loss of luminous flux and a greater color shift over their lifetime. Because there are many different methods of dimming and the effects on the physics of the lamps are highly complex there is as yet no statistically sound information on the performance of the lamps over their lifetime. In addition, there is still no standardized dimming cycle by which the lamps can be reliably tested. The warranted product characteristics cannot therefore be guaranteed for lamps operated at dimmed settings. The operation of OSRAM HCI® POWERBALL® lamps at dimmed settings is not permitted as this results in significant color shifts, bad lumen maintenance and shorter lifetime. As we cannot completely rule out the possibility of the bulb bursting, luminaires for the lamps mentioned above must be equipped with sealed shatter-proof shields that can withstand wide fluctuations in temperature. Operating lamps with a damaged outer bulb is dangerous and therefore not permitted. Lamp operation: Operating high-pressure lamps for short periods in combination with frequent on/off switching will shorten their life. This applies to both cold starting and hot restarts. End of life: To protect the control gear and to avoid radio interference, high-pressure discharge lamps must be replaced as soon as they come to the end of their life. These lamps reach their end of life when ● the light colour of the lamp changes dramatically ● there is a significant loss of brightness ● the lamp no longer ignites ● the lamp starts to cycle (periodically goes out and ignites again). As a lamp reaches the end of its life the risk of bursting increases. This phenomenon is caused by effects not connected with the manufacturer, such as the rectifying effect mentioned earlier. Because of this we strongly recommend changing the lamp no later than when it reaches its average life or if one of the above effects occurs. The following lamps are suitable for open luminaires: ● All HCI®-T/P ● All HCI®-E/P ● All HCI®-R111 ● All HCI®-PAR The use of shields should be considered for safety reasons in each case. HCI® lamps for outdoor applications and damp locations may only be operated in luminaires approved for the purpose. Luminaire design: Luminaire design (thermal design and fuse protection) should be based on the EN 60598-1 standard. Photometric and electrical data: Notes on disposal: All metal halide lamps contain small quantities of mercury. If they break, poisonous mercury vapour may be released. The lamps must be treated as waste requiring special supervision with EEC code 20 01 21 for waste or residue containing mercury and should be passed to a relevant collection or recycling company. Guarantee: A guarantee can only made if suitable control gear is used and the defined operating conditions are met. Safety: OSRAM high-pressure lamps meet the safety requirements defined in IEC 62035. All HCI® lamps are of UV-reduced design. Because of their high operating pressure the following lamps may only be used in fully enclosed luminaires designed to take them: ● All HCI®-TS ● All HCI®-T, all HCI®-TT ● All HCI®-TC ● All HCI®-E ≥ 250 W ● All HCI®-TF ● All HCI®-TM All lamp-specific electrical and photometric data is measured after 100 hours of operation under laboratory conditions on reference equipment. The measurement switching cycle is 11 hours on/ 1 hour off. Unless otherwise indicated, the data relates to the horizontal burning position for TS types and to the base up burning position for other types. The graphs for survival rates and luminous flux behaviour are average values for all wattages and light colours of lamps identical in construction. The spread of the average values has not been taken into account. For detailed information on particular lamp types please contact OSRAM. The luminous flux is virtually unaffected by the ambient temperature outside the luminaire. At low ambient temperatures down to around – 50 C° special igniters are needed. Detailed information on heat accumulation tubes (luminaire simulators) for determining lamp data for HCI®-TS is given in IEC 61167, clause 1.7. Colour deviations: With all metal halide lamps there may be differences in colour from one lamp to the next due to external factors such as mains voltage, type of control gear used, burning position and luminaire design. 23 Lamp life There are a confusing number of definitions for lamp life, and these differ from one region to the next and from one application to the next. The basic definitions for the most common types are given below. Minimum life: Minimum period of time in which a lamp remains in operation under laboratory conditions. This document refers explicitly only to the average life. Economical life: Average life: Average number of hours burned over several groups in which in the group in question half the lamps have failed as the result of a defect (corresponds to 50% failure). Service life: Survival rate: Quantity of working lamps of a group of lamps after a defined number of burning hours. Average value of some groups. Operating characteristics in relation to the supply voltage POWERBALL ≤ 250 W 130 % 120 110 100 PL UL IL 90 Φ 80 70 90 95 100 105 % 110 Mains voltage Φ = Luminous flux PL = Lamp wattage IL = Lamp current UL = Lamp voltage = Not permitted 24 Period of time between group relamping of an installation under the condition that operating costs are minimised and the installation luminous flux does not fall below a particular value. This will vary according to the application. Simplified practical view of the economical life. This is the operating time after which the installation luminous flux (the product of the relative luminous flux and the lamps still in operation) is still around 70% (sometimes 80%). Start-up behaviour (average value) 180 180 160 160 140 140 120 120 100 100 Rel. operating values % POWERBALL HCI-T ≤ 250 W with CCG Rel. operating values % POWERBALL HCI-T ≤ 250 W with PTU 80 60 40 20 0 1 2 3 min 4 Start-up time 80 60 40 20 0 1 2 3 min 4 Start-up time 25 Circuit diagrams L POWERTRONIC PTi (all) N LH LP LL 1 2 D = Choke K = PF correction capacitor LP = Lamp UN = 230 V ac mains voltage (for 2000 W = 400 V ac) Z = Igniter to be installed near the lamp ZL = HF igniter lead to contact plate of lamp For power supplies with a neutral conductor the choke should be connected to the live conductor. The right igniter for the particular lamp type must be used to ensure reliable and safe ignition. Chokes, holder, capacitors and igniters are available from electrical suppliers. Burning positions ϒ s5 Permitted Not permitted Base 8.5 6.5 6,5 8.5 8,5 G22 IEC 7004-75 26 G 8.5 GX 8.5 G12 GU6.5 Spectral power distribution of discharge lamps POWERBALL® HCI® . . ./WDL HCI® .../NDL Visible range from 380 to 780 nm Vertical scale 400 mW 1000 lm · 10 nm POWERBALL® SHOPLIGHT Visible range from 380 to 780 nm Intensity per 10 nm ● All rights reserved. No part of this document may be reproduced, copied or distributed in any form (printed matter, photocopy, etc.) without the written permission of HID M-M, OSRAM Germany. ● This brochure supersedes all previous editions. ● All dimensions, weights, specifications and graphic representations are given without obligation. All design features, dimensions and technical specifications are subject to change without notice. 27 Global presence. OSRAM supplies customers in around 150 countries. • 65 companies and sales offices for 100 countries • 48 countries served by local agents or OSRAM GmbH, Munich OSRAM GmbH Head Office Hellabrunner Strasse 1 81543 Munich Germany Tel.: +49-(0)89-6213-0 Fax: +49-(0)89-6213-2020 www.osram.com Kazakhstan Kenya Latvia Lithuania Malaysia Mexico Norway Philippines Poland Portugal Rumania Russia Serbia-Montenegro Singapore Slovakia South Africa South Korea Spain Sweden Switzerland Taiwan Thailand Turkey Ukraine United Arab Emirates USA Vietnam 104 T001 GB 12/06 CO OSRAM HID Subject to modification without notice. Errors and omissions excepted Argentina Australia Austria Benelux Bosnia-Herzegovina Brazil Bulgaria Canada Chile China Columbia Croatia Czech Republic Denmark Ecuador Egypt Estonia Finland France Germany Great Britain Greece Hungary India Indonesia Iran Italy Japan z Printed on paper treated with chlorine-free bleach OSRAM associated companies and support centres.
4050300873664 价格&库存

很抱歉,暂时无法提供与“4050300873664”相匹配的价格&库存,您可以联系我们找货

免费人工找货