0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
5X20-250.5

5X20-250.5

  • 厂商:

    AMPROBE(安博)

  • 封装:

    -

  • 描述:

    FUSEAM-68

  • 数据手册
  • 价格&库存
5X20-250.5 数据手册
AM-220 & AM-240 Digital Multimeters CAT 600V • Measure: AC/DC Voltage up to 600V, AC/DC Current up to 10A, Resistance, Capacitance, Frequency, Duty Cycle • Temperature measurement with selectable F/C (AM-240 only) • AC/DC micro Amps for sensors diagnosis • Large Backlight LCD Display • Diode Test • Audible Continuity Test • Data Hold • MAX, MIN and Relative measurements • Auto and Manual Ranging • Auto Power Off (can be disabled) • Tilt stand • Safety: CAT III 600V Feature AC/DC Voltage AM-220 AC/DC Current Resistance Capacitance Frequency OPTIONAL ACCESSORIES 3000AAC Flexible Clamp-on Attachment 1000A TRMS AC/DC Clamp-on Attachment 600A AC/DC Clamp-on Attachment 400A AC Clamp-on Attachment Milli-Amps to 30A AC/DC Clamp-on Attachment Dual input Thermocouple adapter with two thermocouples -50°F to 600°F Single Input Thermocouple Temperature Adapter (Recommended for AM-220) Alligator Clips (For test leads) Carrying Case PART NUMBER ACF-3000 AK A-1000 CT-600 AC/DC A400 CT-30 DKTA-620 and two of TPK-56 TMA-K VRC-320 SV-U Duty Cycle Temperature AM-240 400mV 4.000/40.00/400.0/600 V 400/4000µA 40/400 mA 4/10 A 400.0Ω 4.000/40.00/400.0 kΩ 4.000MΩ/40.00 MΩ 40.00/400.0 nF 4.000/40.00/400.0/4000µF 10.00/ 100.0/1000 Hz 10.00/100.0/1000 kHz 10M Hz 0.1%_99.9% -58˚ to 1382˚F (-50˚ to 750˚C) REPLACEMENT PARTS PART NUMBER Thermocouple (AM-240 Only) TPK-59 Test leads with set of alligator clips MTL-90B (alligator clips are not supplied with product) (supplied with product) Fuse 250V, 0.5A Fuse 250V, 10A Instruction Manual www.AMPROBE.com 5X20-250.5 6X32-250V10A www.AMPROBE.com AM-220 & AM-240 Digital Multimeters DC VOLTAGE RANGE Accuracy Resolution 400mV 0.1mV 4V 1mV 40V 10mV ± ( 0.5%+2 ) 400V 100mV 600V ± ( 0.8%+3 ) 1V Overload protection: 600V DC or AC RMS Impedance: 10MΩ, More than 100MΩ on 400mV range AC VOLTAGE RANGE Accuracy Resolution 400mV ± ( 1.5%+3 ) 0.1mV 4V 1mV ± ( 1.0%+2 ) 40V 10mV 400V 100mV 600V ± ( 1.5%+3 ) 1V Average sensing, calibrated to RMS of sine wave Frequency: 40 ~ 400Hz Overload protection: 600V DC or AC RMS Impedance: 10MΩ , More than 100MΩ on 400mV range DC CURRENT RANGE Accuracy Resolution 400µA 0.1µA 4000µA 1µA ± ( 1.2%+3 ) 10µA 40mA 400mA 100µA 4A 1mA 1mA 10A 10mA Overload protection: 0.5A/250V, 10A/250V fuse AC CURRENT RANGE Accuracy Resolution 400µA 0.1µA 4000µA 1µA ± ( 1.5%+3 ) 10µA 40mA 400mA 100µA 4A 1mA ± ( 2.5%+5 ) 10A 10mA Average sensing, calibrated to RMS of sine wave Frequency: 40~400Hz Overload protection: 0.5A/250V, 10A/250V fuse RESISTANCE RANGE Accuracy 400Ω 4kΩ 40kΩ 400kΩ 4MΩ 40MΩ Resolution 0.1Ω 1Ω 10Ω 100Ω 1kΩ 10kΩ ± ( 1.0%+2 ) ± ( 2.0%+3 ) Overload protection: 250V DC or AC RMS CAPACITANCE RANGE 40nF 400nF 4µF 40µF 400µF 4000µF Accuracy ± ( 3.0%+10 ) Resolution 10pF 100pF ± ( 2.5%+5 ) 1nF 10nF ± ( 5.0%+10 ) 100nF ± ( 20.0%+20 ) 10µF Overload protection: 250V DC or AC RMS DIODE AND AUDIBLE CONTINUITY TEST RANGE sr Description Test Condition Display read approximately Forward DC current forward voltage of diode approx. 0.4mA Reversed DC voltage approx. 2.8V Built-in buzzer sounds if Open circuit voltage resistance is less than 50Ω approx. 0.5V Overload protection: 250V DC or AC RMS FREQUENCY RANGE 10Hz 100Hz 1000Hz 10kHz 100kHz 1000kHz 10MHz Accuracy ± ( 0.1%+5 ) Resolution 0.01Hz 0.1Hz 1Hz 10Hz 100Hz 1kHz 10kHz Sensitivity: sine wave 0.6V RMS (10MHz: 1.5V RMS) Overload protection: 250V DC or AC RMS Miramar, FL 33025 • Toll Free: 800-327-5060 • Phone: 954-499-5400 • Fax: 954-499-5418 • www.Amprobe.com www.AMPROBE.com
5X20-250.5 价格&库存

很抱歉,暂时无法提供与“5X20-250.5”相匹配的价格&库存,您可以联系我们找货

免费人工找货