TRANSFORMERS
&
MYRRA
...Of course !
INDUCTORS
TECHNICAL INFORMATION
RATED PRIMARY VOLTAGE (V)
This is the supply voltage assigned to the transformer by the manufacturer.
RATED SECONDARY VOLTAGE (V)
This is the secondary output voltage assigned to the transformer when supplied with the rated primary voltage, frequency range, rated secondary
current, all assigned by the manufacturer for the specified operating conditions of the transformer.
RATED POWER (VA)
The specified power levels in this catalogue are the secondary power levels, in other words, those available when the transformer is loaded. It is the
product of the RMS rated secondary voltage by the RMS rated current. If the transformer has more than one output winding, the rated power
denotes the maximum sum of the products of RMS rated secondary voltage by the RMS rated secondary current, respectively. This rated power is
defined for rated ambient temperature conditions.
example : P = 3,2 VA ta 70/B
The transformer can deliver 3.2VA at maximum ambient (70°C), the load consisting of a resistor load defined by R(load) = U(sec)2/P (assigned U sec &
P values), heating does not exceed the relevant limit for Class B components used in this construction.
NOTE : When the transformer is intended to supply DC voltage and current in conjunction with rectifiers and smoothing capacitors, the VA power
required from the transformer is far higher than the U(DC) and I(DC) product. To help you to determine the true transformer power, our Technical
Department is at your disposal.
AMBIENT TEMPERATURE (ta)
The maximum temperature at which the transformer may be operated continuously under nominal conditions of use. It is the air temperature measured close to the transformer after thermal stabilization when operating at rated conditions.
HEATING
The increase of the winding temperature when operating at rated conditions and maximum ambient temperature. The heating must be determined by
the resistance method.
TEMPERATURE CLASS
The international classification of temperature classes is as follows :
A
E
B
F
105°C
120°C
130°C
155°C
H
200
220
250
180 °C
200 °C
220 °C
250 °C
It defines the maximum temperature the transformer components must withstand in continuous operation, in compliance with the N° 85 IEC publication classification. There insulating materials are therefore certificated for the thermal index corresponding to the declared class in accordance with
N° 216 IEC standard.
PARTICULAR POINTS OF EN 61558-2-6 STANDARD FOR SAFETY TRANSFORMERS
On-load secondary voltage tolerance.
This should not differ from the rated value by more than :
10% for transformers with build-in resistance to short-circuits (a supplement of 5% is granted on the 2 nd secondary for tranformers with 2
secondaries).
5% for other transformers whatever the secondaries number.
Off-load secondary voltage.
The values given in this catalogue are maximum theoretical values.
NOTE : For safety transformers, this should never exceed 50 V rms. In the case of a transformer with several secondaries, the sum of the
secondary voltages should be less tan 50 V rms.
ADAPTED TRANSFORMERS FROM THE STANDARDS SERIES
Any transformer whose requires Power and Ambient corresponding to those of our 44000 & 45000 range, and whose secondary voltage can fit in our
minimum to maximum secondary range will be covered by EN61558-2-6,EN60950, or UL506 approvals, depending on the effective choice .
SPECIAL TRANFORMERS
MYRRA can use the 44000, 45000 or 46000 standard ranges to examine any transformer for compliance with your specifications and with international standards.
On request, we can add thermal protection, thermal fuse, thermal switch-CTP.
In certain cases, the addition of thermal protection enables the ambient temperature to be increased, while still complying with EN 61558.
4
SERIE 44000
EN 61558-2-6
• Vacuum filling
• Two compartments bobbins
• Self-extinguishing plastics UL 94 VO
• Degree of protection IP 00
• 40 grams weight
• Resin class B CEI 85 (20 000 h testing to CEI 126)
• Inherently short-circuits proof
• Insulation voltage 4 KV
• 100 % tested production
• Certification : CCA procedure on request
7
5
6 7
5
1
9 10
1
5
UL 1585
QUALITY IN SERIES
PRIMARY VOLTAGE
117 V
Protection
9
6 7
EN 60950
9 10
1
Recommended layout for transformers
with 1 secondary winding
(Allows the use of a transformer
with 2 secondary windings)
Reference
Secondary
voltage
V
Secondary
current
mA
No-load
voltage
V
Ambient
Temperature
°C
Rating
VA
44025
6
100
9,94
T 70 B
0,6
44026
9
66
14,95
T 70 B
0,6
44027
12
50
19,9
T 70 B
0,6
44028
15
40
24,9
T 70 B
0,6
44029
18
33
29,9
T 70 B
0,6
44030
24
25
39,8
T 70 B
0,6
44031
2x6
2 x 50
2 x 9,94
T 70 B
0,6
44032
2x9
2 x 33
2 x 14,95
T 70 B
0,6
44033
2 x 12
2 x 25
2 x 19,9
T 70 B
0,6
44034
2 x 15
2 x 20
2 x 24,9
T 70 B
0,6
44035
2 x 18
2 x 17
2 x 29,9
T 70 B
0,6
44036
2 x 24
2 x 12
2 x 39,8
T 70 B
0,6
PRIMARY VOLTAGE
230 V
Protection
Reference
Secondary
voltage
V
Secondary
current
mA
No-load
voltage
V
Ambient
Temperature
°C
Rating
VA
44013
6
100
9,94
T 70 B
0,6
44014
9
66
14,95
T 70 B
0,6
44015
12
50
19,9
T 70 B
0,6
44016
15
40
24,9
T 70 B
0,6
44017
18
33
29,9
T 70 B
0,6
44018
24
25
39,8
T 70 B
0,6
44019
2x6
2 x 50
2 x 9,94
T 70 B
0,6
44020
2x9
2 x 33
2 x 14,95
T 70 B
0,6
44021
2 x 12
2 x 25
2 x 19,9
T 70 B
0,6
44022*
2 x 15
2 x 20
2 x 24,9
T 70 B
0,6
44023*
2 x 18
2 x 17
2 x 29,9
T 70 B
0,6
44024*
2 x 24
2 x 12
2 x 39,8
T 70 B
0,6
*To be noted : * marked transformers are non approved.
Those transformers meet all requirement of EN 61558-2-4.
5
44000 SERIES
EI 30-5
ENCAPSULATED TRANSFORMERS
0,6 VA
1-1,8 VA
EI 30-10,5
SERIE 44000
PRIMARY VOLTAGE
117 V
6
44000 SERIES
ENCAPSULATED TRANSFORMERS
Protection
Reference
Secondary
voltage
V
Secondary
current
mA
No-load
voltage
V
Ambient
Temperature
°C
Rating
VA
44061
6
167
8,6
T 70 B
1
44062
9
111
12,9
T 70 B
1
44063
12
83
17,2
T 70 B
1
44064
15
67
21,6
T 70 B
1
44065
18
56
25,9
T 70 B
1
44066
24
42
37,9
T 70 B
1
44067
2X6
2 x 83
2 x 8,6
T 70 B
1
44068
2x9
2 x 56
2 x 12,9
T 70 B
1
44069
2 x 12
2 x 42
2 x 19
T 70 B
1
44070
2 x 15
2 x 33
2 x 23,6
T 70 B
1
44071
2 x 18
2 x 28
2 x 24,9
T 70 B
1
44072
2 x 24
2 x 21
2 x 37,9
T 70 B
1
44338
6
250
10,1
ta 70/B
1,5
44339
9
167
15,3
ta 70/B
1,5
44340
12
125
20,2
ta 70/B
1,5
44341
15
100
25,3
ta 70/B
1,5
44342
18
83
31,2
ta 70/B
1,5
44343
24
63
43,3
ta 70/B
1,5
44344
2x6
125
2 x 10,1
ta 70/B
1,5
44345
2x9
83
2 x 15,3
ta 70/B
1,5
44346
2 x 12
63
2 x 20,2
ta 70/B
1,5
44347
2 x 15
50
2 x 25,0
ta 70/B
1,5
44348*
2 x 18
42
2 x 31
ta 70/B
1,5
44349*
2 x 24
31
2 x 43
ta 70/B
1,5
44840
6
300
10,1
ta 70/B
1,8
44841
9
200
15,2
ta 70/B
1,8
44842
12
150
20,3
ta 70/B
1,8
44843
15
120
27,3
ta 70/B
1,8
44844
18
100
30,4
ta 70/B
1,8
44845
24
75
40,6
ta 70/B
1,8
44846
2x6
2 x 150
2 x 10,1
ta 70/B
1,8
44847
2x9
2 x 100
2 x 15,2
ta 70/B
1,8
44848
2 x 12
2 x 75
2 x 20,3
ta 70/B
1,8
44849
2 x 15
2 x 60
2 x 27,3
ta 70/B
1,8
• Vacuum filling
• Two compartments bobbins
• Self-extinguishing plastics UL 94 VO
• Degree of protection IP 00
• 70 grams weight
• Resin class B CEI 85 (20 000 h testing to CEI 126)
• Inherently short-circuits proof
• 30 V and 36 V models are VDE EN 61558-2-6 certified
(production on request)
1 Secondary winding
7
9
5
1
Primary winding
6 7
9 10
2 Secondary windings
5
1
Primary winding
Recommended layout for transformers
with 1 secondary winding
6 7
5
9 10
1
(Allows the use of a transformer
with 2 secondary windings)
1-1,8 VA
EI 30-10,5
SERIE 44000
EN 60950
UL 1585
Secondary
voltage
V
Secondary
current
mA
No-load
voltage
V
Ambient
Temperature
°C
Rating
VA
44049•
6
167
8,6
T 70 B
1
44050•
9
111
12,9
T 70 B
1
44051•
12
83
17,2
T 70 B
1
44052•
15
67
21,6
T 70 B
1
44053•
18
56
25,9
T 70 B
1
44054•
24
42
37,9
T 70 B
1
44055•
2x6
2 x 83
2 x 8,6
T 70 B
1
44056•
2x9
2 x 56
2 x 12,9
T 70 B
1
44057•
2 x 12
2 x 42
2 x 19
T 70 B
1
44058•
2 x 15
2 x 33
2 x 23,6
T 70 B
1
44059•
2 x 18
2 x 28
2 x 24,9
T 70 B
1
2 x 24
• Items usually available on stock
2 x 21
2 x 37,9
T 70 B
1
Protection
• Insulation voltage 4 KV
• 100 % tested production
• Certification : CCA procedure on request
*To be noted 2 x 15 V and 2 x 24 V models are non-approved.
Those transformers meet all requirement of EN 61558-2-4
Reference
44060*•
44326
6
250
10,1
ta 70/B
1,5
44327
9
167
15,3
ta 70/B
1,5
44328
12
125
20,2
ta 70/B
1,5
44329
15
100
25,3
ta 70/B
1,5
44330
18
83
31,2
ta 70/B
1,5
44331
24
63
43,3
ta 70/B
1,5
44332
2x6
125
2 x 10,1
ta 70/B
1,5
44333
2x9
83
2 x 15,3
ta 70/B
1,5
44334
2 x 12
63
2 x 20,2
ta 70/B
1,5
44335
2 x 15
50
2 x 25,0
ta 70/B
1,5
44336*
2 x 18
42
2 x 31
ta 70/B
1,5
44337*
2 x 24
31
2 x 43
ta 70/B
1,5
44830
6
300
10,1
ta 70/B
1,8
44831
9
200
15,2
ta 70/B
1,8
44832
12
150
20,3
ta 70/B
1,8
44833
15
120
27,3
ta 70/B
1,8
44834
18
100
30,4
ta 70/B
1,8
44835
24
75
40,6
ta 70/B
1,8
44836
2x6
2 x 150
2 x 10,1
ta 70/B
1,8
44837
2x9
2 x 100
2 x 15,2
ta 70/B
1,8
44838
2 x 12
2 x 75
2 x 20,3
ta 70/B
1,8
44839*
2 x 15
2 x 60
2 x 27,3
ta 70/B
1,8
7
44000 SERIES
EN 61558-2-6
ENCAPSULATED TRANSFORMERS
PRIMARY VOLTAGE
230 V
1,5-1,8 VA
EI 30-12,5
SERIE 44000
PRIMARY VOLTAGE
117 V
Protection
Reference
Secondary
voltage
V
Secondary
current
mA
No-load
voltage
V
Ambient
Temperature
°C
Rating
VA
44097
6
250
9,7
T 70 B
1,5
44098
9
167
14,5
T 70 B
1,5
44099
12
125
19,3
T 70 B
1,5
44100
15
100
24,2
T 70 B
1,5
44101
18
83
29,8
T 70 B
1,5
44102
24
63
38,6
T 70 B
1,5
44103
2X6
2 x 125
2 x 9,7
T 70 B
1,5
44104
2x9
2 x 83
2 x 15
T 70 B
1,5
44105
2 x 12
2 x 63
2 x 19,3
T 70 B
1,5
44106
2 x 15
2 x 50
2 x 24,2
T 70 B
1,5
44107
2 x 18
2 x 42
2 x 29
T 70 B
1,5
44108
2 x 24
2 x 31
2 x 38,6
T 70 B
1,5
44726
6
283
9,8
T 50 B
1,7
44727
9
189
14,8
T 50 B
1,7
44728
12
142
19,7
T 50 B
1,7
44729
15
113
24,6
T 50 B
1,7
5
1
Primary winding
44730
18
94
30,3
T 50 B
1,7
2 Secondary windings
44731
24
71
39,3
T 50 B
1,7
44732
2x6
2 x 142
2 x 9,8
T 50 B
1,7
44733
2x9
2 x 94
2 x 15,2
T 50 B
1,7
44734
2 x 12
2 x 71
2 x 19,7
T 50 B
1,7
44735
2 x 15
2 x 57
2 x 24,6
T 50 B
1,7
44736
2 x 18
2 x 47
2 x 29,5
T 50 B
1,7
44737
2 x 24
2 x 35
2 x 39,3
T 50 B
1,7
• Vacuum filling
• Two compartments bobbins
• Self-extinguishing plastics UL 94 VO
• Degree of protection IP 00
• 80 grams weight
• Resin class B CEI 85 (20 000 h testing to CEI 126)
• Inherently short-circuits proof
• 30 V model is VDE EN 61558-2-6 certified
(production on request)
1 Secondary winding
7
6 7
5
9
9 10
1
Primary winding
8
44000 SERIES
ENCAPSULATED TRANSFORMERS
Recommended layout for transformers
with 1 secondary winding
44738
6
300
9,8
T 40 B
1,8
44739
9
200
14,8
T 40 B
1,8
44740
12
150
19,7
T 40 B
1,8
44741
15
120
24,6
T 40 B
1,8
44742
18
100
30,3
T 40 B
1,8
44743
24
75
39,3
T 40 B
1,8
44744
2x6
2 x 150
2 x 9,8
T 40 B
1,8
44745
2x9
2 x 100
2 x 15,2
T 40 B
1,8
44746
2 x 12
2 x 75
2 x 19,7
T 40 B
1,8
44747
2 x 15
2 x 60
2 x 24,6
T 40 B
1,8
44748
2 x 18
2 x 50
2 x 29,5
T 40 B
1,8
44749
2 x 24
2 x 38
2 x 39,3
T 40 B
1,8
6 7
5
9 10
1
(Allows the use of a transformer
with 2 secondary windings)
QUALITY IN SERIES
1,5-1,8 VA
EI 30-12,5
SERIE 44000
Secondary
current
mA
No-load
voltage
V
Ambient
Temperature
°C
Rating
VA
EN 61558-2-6
EN 60950
UL 1585
44085•
6
250
9,7
T 70 B
1,5
• Insulation voltage 4 KV
• 100 % tested production
• Certification : CCA procedure on request
44086•
9
167
14,5
T 70 B
1,5
44087•
12
125
19,3
T 70 B
1,5
44088•
15
100
24,2
T 70 B
1,5
44089•
18
83
29,8
T 70 B
1,5
*To be noted : 2 x 18 V and 2 x 24 V models are nonapproved.
Those transformers meet all requirement of EN 61558-2-4
44090•
24
63
38,6
T 70 B
1,5
44091•
2X6
2 x 125
2 x 9,7
T 70 B
1,5
44092•
2x9
2 x 83
2 x 15
T 70 B
1,5
44093•
2 x 12
2 x 63
2 x 19,3
T 70 B
1,5
44094•
2 x 15
2 x 50
2 x 24,2
T 70 B
1,5
44095*•
2 x 18
2 x 42
2 x 29
T 70 B
1,5
2 x 24
• Items usually available on stock
2 x 31
2 x 38,6
T 70 B
1,5
Reference
44096*•
44647
6
283
9,8
T 50 B
1,7
44648
9
189
14,8
T 50 B
1,7
44649
12
142
19,7
T 50 B
1,7
44650
15
113
24,6
T 50 B
1,7
44651
18
94
30,3
T 50 B
1,7
44652
24
71
39,3
T 50 B
1,7
44653
2x6
2 x 142
2 x 9,8
T 50 B
1,7
44654
2x9
2 x 94
2 x 15,2
T 50 B
1,7
44655
2 x 12
2 x 71
2 x 19,7
T 50 B
1,7
44656
2 x 15
2 x 57
2 x 24,6
T 50 B
1,7
44483*
2 x 18
2 x 47
2 x 29,5
T 50 B
1,7
44484*
2 x 24
2 x 35
2 x 39,3
T 50 B
1,7
44657
6
300
9,8
T 40 B
1,8
44658
9
200
14,8
T 40 B
1,8
44659
12
150
19,7
T 40 B
1,8
44660
15
120
24,6
T 40 B
1,8
44661
18
100
30,3
T 40 B
1,8
44662
24
75
39,3
T 40 B
1,8
44663
2x6
2 x 150
2 x 9,8
T 40 B
1,8
44664
2x9
2 x 100
2 x 15,2
T 40 B
1,8
44665
2 x 12
2 x 75
2 x 19,7
T 40 B
1,8
44666
2 x 15
2 x 60
2 x 24,6
T 40 B
1,8
44485*
2 x 18
2 x 50
2 x 29,5
T 40 B
1,8
44486*
2 x 24
2 x 38
2 x 39,3
T 40 B
1,8
9
44000 SERIES
Secondary
voltage
V
Protection
ENCAPSULATED TRANSFORMERS
PRIMARY VOLTAGE
230 V
2-2,4 VA
EI 30-15,5
SERIE 44000
PRIMARY VOLTAGE
117 V
44000 SERIES
ENCAPSULATED TRANSFORMERS
Protection
10
Reference
Secondary
voltage
V
Secondary
current
mA
No-load
voltage
V
Ambient
Temperature
°C
Rating
VA
44133
6
333
10,4
T 70 B
2
44134
9
222
15,5
T 70 B
2
44135
12
167
20,7
T 70 B
2
44136
15
133
25,8
T 70 B
2
44137
18
111
30,8
T 70 B
2
44138
24
83
41,4
T 70 B
2
44139
2X6
2 x 167
2 x 10,4
T 70 B
2
44140
2x9
2 x 111
2 x 15,4
T 70 B
2
44141
2 x 12
2 x 83
2 x 20,7
T 70 B
2
44142
2 x 15
2 x 67
2 x 25,8
T 70 B
2
44143
2 x 18
2 x 56
2 x 30,8
T 70 B
2
44144
2 x 24
2 x 42
2 x 41,4
T 70 B
2
44750
6
383
10,5
T 50 B
2,3
44751
9
256
15,5
T 50 B
2,3
44752
12
192
21
T 50 B
2,3
44753
15
153
25,3
T 50 B
2,3
44754
18
128
31
T 50 B
2,3
44755
24
96
42
T 50 B
2,3
44756
2x6
2 x 192
2 x 10,5
T 50 B
2,3
44757
2x9
2 x 128
2 x 15,5
T 50 B
2,3
44758
2 x 12
2 x 96
2 x 21
T 50 B
2,3
44759
2 x 15
2 x 77
2 x 24,5
T 50 B
2,3
44760
2 x 18
2 x 64
2 x 31
T 50 B
2,3
44761
2 x 24
2 x 48
2 x 42
T 50 B
2,3
44762
6
400
10,5
T 40 B
2,4
44763
9
267
15,5
T 40 B
2,4
44764
12
200
21
T 40 B
2,4
44765
15
160
25,3
T 40 B
2,4
44766
18
133
31
T 40 B
2,4
44767
24
100
42
T 40 B
2,4
44768
2x6
2 x 200
2 x 10,5
T 40 B
2,4
44769
2x9
2 x 133
2 x 15,5
T 40 B
2,4
44770
2 x 12
2 x 100
2 x 21
T 40 B
2,4
44771
2 x 15
2 x 80
2 x 24,5
T 40 B
2,4
44772
2 x 18
2 x 67
2 x 31
T 40 B
2,4
44773
2 x 24
2 x 50
2 x 42
T 40 B
2,4
• Vacuum filling
• Two compartments bobbins
• Self-extinguishing plastics UL 94 VO
• Degree of protection IP 00
• 100 grams weight
• Resin class B CEI 85 (20 000 h testing to CEI 126)
• Inherently short-circuits proof
• 30 V model is VDE EN 61558-2-6 certified
(production on request)
• Insulation voltage 4 KV
1 Secondary winding
7
5
9
1
Primary winding
6 7
9 10
2 Secondary windings
5
1
Primary winding
Recommended layout for transformers
with 1 secondary winding
6 7
5
9 10
1
(Allows the use of a transformer
with 2 secondary windings)
2-2,4 VA
EI 30-15,5
SERIE 44000
Secondary
current
mA
No-load
voltage
V
Ambient
Temperature
°C
Rating
VA
EN 61558-2-6
EN 60950
UL 1585
44121•
6
333
10,4
T 70 B
2
• 100 % tested production
• Certification : CCA procedure on request
44122•
9
222
15,5
T 70 B
2
44123•
12
167
20,7
T 70 B
2
44124•
15
133
25,8
T 70 B
2
*To be noted : 2 x 18 V and 2 x 24 V models are nonapproved.
Those transformers meet all requirement of EN 61558-2-4
44125•
18
111
30,8
T 70 B
2
44126•
24
83
41,4
T 70 B
2
44127•
2X6
2 x 167
2 x 10,4
T 70 B
2
44128•
2x9
2 x 111
2 x 15,4
T 70 B
2
44129•
2 x 12
2 x 83
2 x 20,7
T 70 B
2
44130•
2 x 15
2 x 67
2 x 25,8
T 70 B
2
44131*•
2 x 18
2 x 56
2 x 30,8
T 70 B
2
2 x 24
• Items usually available on stock
2 x 42
2 x 41,4
T 70 B
2
Reference
44132*•
44667
6
383
10,5
T 50 B
2,3
44668
9
256
15,5
T 50 B
2,3
44669
12
192
21
T 50 B
2,3
44670
15
153
25,3
T 50 B
2,3
44671
18
128
31
T 50 B
2,3
44672
24
96
42
T 50 B
2,3
44673
2x6
2 x 192
2 x 10,5
T 50 B
2,3
44674
2x9
2 x 128
2 x 15,5
T 50 B
2,3
44675
2 x 12
2 x 96
2 x 21
T 50 B
2,3
44676
2 x 15
2 x 77
2 x 24,5
T 50 B
2,3
44487*
2 x 18
2 x 64
2 x 31
T 50 B
2,3
44488*
2 x 24
2 x 48
2 x 42
T 50 B
2,3
44677
6
400
10,5
T 40 B
2,4
44678
9
267
15,5
T 40 B
2,4
44679
12
200
21
T 40 B
2,4
44680
15
160
25,3
T 40 B
2,4
44681
18
133
31
T 40 B
2,4
44682
24
100
42
T 40 B
2,4
44683
2x6
2 x 200
2 x 10,5
T 40 B
2,4
44684
2x9
2 x 133
2 x 15,5
T 40 B
2,4
44685
2 x 12
2 x 100
2 x 21
T 40 B
2,4
44686
2 x 15
2 x 80
2 x 24,5
T 40 B
2,4
44489*
2 x 18
2 x 67
2 x 31
T 40 B
2,4
44490*
2 x 24
2 x 50
2 x 42
T 40 B
2,4
44000 SERIES
Secondary
voltage
V
Protection
ENCAPSULATED TRANSFORMERS
PRIMARY VOLTAGE
230 V
11
2,3-2,8 VA
EI 30-18
SERIE 44000
PRIMARY VOLTAGE
117 V
Protection
Reference
Secondary
voltage
V
Secondary
current
mA
No-load
voltage
V
Ambient
Temperature
°C
Rating
VA
44169
6
383
10,5
T 70 B
2,3
44170
9
256
15,7
T 70 B
2,3
44171
12
192
21
T 70 B
2,3
44172
15
153
25,9
T 70 B
2,3
44173
18
128
31,4
T 70 B
2,3
44174
24
96
41,9
T 70 B
2,3
44175
2X6
2 x 192
2 x 10,5
T 70 B
2,3
44176
2x9
2 x 128
2 x 15,7
T 70 B
2,3
44177
2 x 12
2 x 96
2 x 21
T 70 B
2,3
44178
2 x 15
2 x 77
2 x 25,9
T 70 B
2,3
44179
2 x 18
2 x 64
2 x 31,4
T 70 B
2,3
44180
2 x 24
2 x 48
2 x 41,9
T 70 B
2,3
44774
6
450
10,5
T 50 B
2,7
44775
9
300
15,4
T 50 B
2,7
44776
12
225
21,1
T 50 B
2,7
44777
15
180
26,3
T 50 B
2,7
5
1
Primary winding
44778
18
150
30,9
T 50 B
2,7
2 Secondary windings
44779
24
113
42
T 50 B
2,7
44780
2x6
2 x 225
2 x 10,5
T 50 B
2,7
44781
2x9
2 x 150
2 x 15,4
T 50 B
2,7
44782
2 x 12
2 x 113
2 x 21,1
T 50 B
2,7
44783
2 x 15
2 x 90
2 x 26,3
T 50 B
2,7
44784
2 x 18
2 x 75
2 x 31,5
T 50 B
2,7
44785
2 x 24
2 x 56
2 x 42,1
T 50 B
2,7
• Vacuum filling
• Two compartments bobbins
• Self-extinguishing plastics UL 94 VO
• Degree of protection IP 00
• 70 grams weight
• Resin class B CEI 85 (20 000 h testing to CEI 126)
• Inherently short-circuits proof
• 30 V model is VDE EN 61558-2-6 certified
(production on request)
1 Secondary winding
7
6 7
5
9
9 10
1
Primary winding
44000 SERIES
ENCAPSULATED TRANSFORMERS
Recommended layout for transformers
with 1 secondary winding
12
44786
6
467
10,5
T 40 B
2,8
44787
9
311
15,4
T 40 B
2,8
44788
12
233
21,1
T 40 B
2,8
44789
15
187
26,3
T 40 B
2,8
44790
18
156
30,9
T 40 B
2,8
44791
24
117
42,1
T 40 B
2,8
44792
2x6
2 x 233
2 x 10,5
T 40 B
2,8
44793
2x9
2 x 156
2 x 15,4
T 40 B
2,8
44794
2 x 12
2 x 117
2 x 21,1
T 40 B
2,8
44795
2 x 15
2 x 93
2 x 26,3
T 40 B
2,8
44796
2 x 18
2 x 77
2 x 31,5
T 40 B
2,8
44797
2 x 24
2 x 58
2 x 42,1
T 40 B
2,8
6 7
5
9 10
1
(Allows the use of a transformer
with 2 secondary windings)
EN 60950
SERIE 44000
PRIMARY VOLTAGE
230 V
UL 1585
• Insulation voltage 4 KV
• 100 % tested production
• Certification : CCA procedure on request
*To be noted : 2 x 18 V and 2 x 24 V models are nonapproved.
Those transformers meet all requirement of EN 61558-2-4
Secondary
voltage
V
Secondary
current
mA
No-load
voltage
V
Ambient
Temperature
°C
Rating
VA
44157•
6
383
10,5
T 70 B
2,3
44158•
9
256
15,7
T 70 B
2,3
44159•
12
192
21
T 70 B
2,3
44160•
15
153
25,9
T 70 B
2,3
44161•
18
128
31,4
T 70 B
2,3
44162•
24
96
41,9
T 70 B
2,3
44163•
2X6
2 x 192
2 x 10,5
T 70 B
2,3
44164•
2x9
2 x 128
2 x 15,7
T 70 B
2,3
44165•
2 x 12
2 x 96
2 x 21
T 70 B
2,3
44166•
2 x 15
2 x 77
2 x 25,9
T 70 B
2,3
44167*•
2 x 18
2 x 64
2 x 31,4
T 70 B
2,3
2 x 24
• Items usually available on stock
2 x 48
2 x 41,9
T 70 B
2,3
Protection
Reference
44168*•
44687
6
450
10,5
T 50 B
2,7
44688
9
300
15,4
T 50 B
2,7
44689
12
225
21,1
T 50 B
2,7
44690
15
180
26,3
T 50 B
2,7
44691
18
150
30,9
T 50 B
2,7
44692
24
113
42
T 50 B
2,7
44693
2x6
2 x 225
2 x 10,5
T 50 B
2,7
44694
2x9
2 x 150
2 x 15,4
T 50 B
2,7
44695
2 x 12
2 x 113
2 x 21,1
T 50 B
2,7
44696
2 x 15
2 x 90
2 x 26,3
T 50 B
2,7
44491*
2 x 18
2 x 75
2 x 31,5
T 50 B
2,7
44492*
2 x 24
2 x 56
2 x 42,1
T 50 B
2,7
44697
6
467
10,5
T 40 B
2,8
44698
9
311
15,4
T 40 B
2,8
44699
12
233
21,1
T 40 B
2,8
44700
15
187
26,3
T 40 B
2,8
44701
18
156
30,9
T 40 B
2,8
44702
24
117
42,1
T 40 B
2,8
44703
2x6
2 x 233
2 x 10,5
T 40 B
2,8
44704
2x9
2 x 156
2 x 15,4
T 40 B
2,8
44705
2 x 12
2 x 117
2 x 21,1
T 40 B
2,8
44706
2 x 15
2 x 93
2 x 26,3
T 40 B
2,8
44493*
2 x 18
2 x 70
2 x 31,5
T 40 B
2,8
44494*
2 x 24
2 x 58
2 x 42,1
T 40 B
2,8
44000 SERIES
EN 61558-2-6
EI 30-18
ENCAPSULATED TRANSFORMERS
2,3-2,8 VA
13
3,2 VA
EI 38-13,6
SERIE 44000
PRIMARY VOLTAGE
117 V
Secondary
protection
mA
Reference
Secondary
voltage
V
Secondary
current
mA
No-load
voltage
V
Ambient
Temperature
°C
Rating
VA
630
44205
6
533
8
T 70 B
3,2
400
44206
9
356
12
T 70 B
3,2
315
44207
12
267
16
T 70 B
3,2
250
44208
15
213
20
T 70 B
3,2
200
44209
18
178
24,1
T 70 B
3,2
160
44210
24
133
32,1
T 70 B
3,2
315
44211
2x6
2 x 267
2x8
T 70 B
3,2
200
44212
2x9
2 x 178
2 x 12
T 70 B
3,2
160
44213
2 x 12
2 x 133
2 x 16
T 70 B
3,2
125
44214
2 x 15
2 x 107
2 x 20
T 70 B
3,2
100
44215
2 x 18
2 x 89
2 x 24
T 70 B
3,2
80
44216
2 x 24
2 x 67
2 x 32,1
T 70 B
3,2
5 VA
EI 42-14,8
44000 SERIES
ENCAPSULATED TRANSFORMERS
2 Secondary windings 1 Secondary winding
6 7
6 7
9 10
9 10
6 7
9 10
5
5
Primary
winding
1
5
Primary
winding
1
1
Recommended layout
for transformers with
1 secondary winding
(Allows the use of a
transformer with
2 secondary windings)
SERIE 44000
PRIMARY VOLTAGE
117 V
14
• Vacuum filling
• Two compartments bobbins
• Self-extinguishing plastics UL 94 VO
• Degree of protection IP 00
• 150 grams weight
• Resin class B CEI 85 (20 000 h testing to CEI 126)
• Fuse protection on secondary side (see diagram) to be assumed
by customer
Secondary
protection
mA
Reference
Secondary
voltage
V
Secondary
current
mA
No-load
voltage
V
Ambient
Temperature
°C
Rating
VA
800
44241
6
833
8,4
T 50 B
5
630
44242
9
556
12,6
T 50 B
5
400
44243
12
417
16,9
T 50 B
5
315
44244
15
333
21
T 50 B
5
315
44245
18
278
25,3
T 50 B
5
200
44246
24
208
33,7
T 50 B
5
400
44247
2x6
2 x 417
2 x 8,4
T 50 B
5
315
44248
2x9
2 x 278
2 x 12,6
T 50 B
5
200
44249
2 x 12
2 x 208
2 x 16,9
T 50 B
5
160
44250
2 x 15
2 x 167
2 x 21
T 50 B
5
160
44251
2 x 18
2 x 139
2 x 25,3
T 50 B
5
100
44252
2 x 24
2 x 104
2 x 33,7
T 50 B
5
• Vacuum filling
• Two compartments bobbins
• Self-extinguishing plastics UL 94 VO
• Degree of protection IP 00
• 200 grams weight
• Resin class B CEI 85 (20 000 h testing to CEI 126)
• Fuse protection on secondary side (see diagram) to be assumed
by customer
6 7
9 10
6 7
9 10
2 Secondary windings 1 Secondary winding
6 7
5
5
Primary
winding
1
5
Primary
winding
1
9 10
1
Recommended layout
for transformers with
1 secondary winding
(Allows the use of a
transformer with
2 secondary windings)
EI 38-13,6
PRIMARY VOLTAGE
230 V
EN 60950
• 30 V and 36 V models are VDE EN 61558-2-6 certified
(production on request)
• Insulation voltage 4 KV
• 100 % tested production
• Certification : CCA procedure on request
Secondary
protection
mA
Reference
Secondary
voltage
V
Secondary
current
mA
No-load
voltage
V
Ambient
Temperature
°C
Rating
VA
630
44193
6
533
8
T 70 B
3,2
400
44194
9
356
12
T 70 B
3,2
315
44195
12
267
16
T 70 B
3,2
250
44196
15
213
20
T 70 B
3,2
200
44197
18
178
24,1
T 70 B
3,2
160
44198
24
133
32,1
T 70 B
3,2
315
44199
2x6
2 x 267
2x8
T 70 B
3,2
200
44200
2x9
2 x 178
2 x 12
T 70 B
3,2
160
44201
2 x 12
2 x 133
2 x 16
T 70 B
3,2
125
44202
2 x 15
2 x 107
2 x 20
T 70 B
3,2
100
44203
2 x 18
2 x 89
2 x 24
T 70 B
3,2
80
44204*
2 x 24
2 x 67
2 x 32,1
T 70 B
3,2
4.5+0.5
*To be noted : 2 x 24 V model is non-approved.
Those transformers meet all requirement of EN 61558-2-4
5 VA
EI 42-14,8
EN 61558-2-6
SERIE 44000
• 30 V and 36 V models are VDE EN 61558-2-6 certified
(production on request)
• Insulation voltage 4 KV
• 100 % tested production
• Certification : CCA procedure on request
*To be noted : 2 x 24 V model is non-approved.
Those transformers meet all requirement of EN 61558-2-4
5+0.5
PRIMARY VOLTAGE
230 V
EN 60950
Secondary
protection
mA
Reference
Secondary
voltage
V
Secondary
current
mA
No-load
voltage
V
Ambient
Temperature
°C
Rating
VA
800
44229
6
833
8,4
T 50 B
5
630
44230
9
556
12,6
T 50 B
5
400
44231
12
417
16,9
T 50 B
5
315
44232
15
333
21
T 50 B
5
315
44233
18
278
25,3
T 50 B
5
200
44234
24
208
33,7
T 50 B
5
400
44235
2x6
2 x 417
2 x 8,4
T 50 B
5
315
44236
2x9
2 x 278
2 x 12,6
T 50 B
5
200
44237
2 x 12
2 x 208
2 x 16,9
T 50 B
5
160
44238
2 x 15
2 x 167
2 x 21
T 50 B
5
160
44239
2 x 18
2 x 139
2 x 25,3
T 50 B
5
100
44240*
2 x 24
2 x 104
2 x 33,7
T 50 B
5
44000 SERIES
EN 61558-2-6
SERIE 44000
ENCAPSULATED TRANSFORMERS
3,2 VA
15
10 VA
EI 48-16,8
SERIE 44000
PRIMARY VOLTAGE
117 V
Primary
protection
mA
Reference
Secondary
voltage
V
Secondary
current
mA
No-load
voltage
V
Ambient
Temperature
°C
Rating
VA
125
44277
6
1667
7,2
T 50 B
10
125
44278
9
1111
10,8
T 50 B
10
125
44279
12
833
14,4
T 50 B
10
125
44280
15
667
18,1
T 50 B
10
125
44281
18
556
21,6
T 50 B
10
125
44282
24
417
28,9
T 50 B
10
125
44283
2x6
2 x 833
2 x 7,2
T 50 B
10
125
44284
2x9
2 x 556
2 x 10,8
T 50 B
10
125
44285
2 x 12
2 x 417
2 x 14,4
T 50 B
10
125
44286
2 x 15
2 x 333
2 x 18,1
T 50 B
10
125
44287
2 x 18
2 x 278
2 x 21,6
T 50 B
10
125
44288
2 x 24
2 x 208
2 x 28,9
T 50 B
10
16 VA
EI 54-18,8
44000 SERIES
ENCAPSULATED TRANSFORMERS
2 Secondary
windings
7 8
11 12
1 Secondary
winding
7 8
11 12
78
11 12
6
6
Primary
winding
6
1
Primary
winding
1
1
Recommended layout
for transformers with
1 secondary winding
(Allows the use of a
transformer with
2 secondary windings)
SERIE 44000
PRIMARY VOLTAGE
117 V
16
• Vacuum filling
• Two compartments bobbins
• Self-extinguishing plastics UL 94 VO
• Degree of protection IP 00
• 300 grams weight
• Resin class B CEI 85 (20 000 h testing to CEI 126)
• Fuse protection on primary side (see diagram) to be assumed
by customer
Secondary
protection
mA
Reference
Secondary
voltage
V
Secondary
current
mA
No-load
voltage
V
Ambient
Temperature
°C
Rating
VA
2,5
44313
6
2667
7,4
T 50 B
16
2,0
44314
9
1778
11,1
T 50 B
16
1,25
44315
12
1333
14,7
T 50 B
16
1
44316
15
1067
18,4
T 50 B
16
1
44317
18
889
22,1
T 50 B
16
0,63
44318
24
667
29,3
T 50 B
16
1,25
44319
2x6
2 x 1333
2 x 7,4
T 50 B
16
1
44320
2x9
2 x 889
2 x 11,1
T 50 B
16
0,63
44321
2 x 12
2 x 667
2 x 14,7
T 50 B
16
0,5
44322
2 x 15
2 x 533
2 x 18,4
T 50 B
16
0,5
44323
2 x 18
2 x 444
2 x 22
T 50 B
16
0,315
44324
2 x 24
2 x 333
2 x 29,3
T 50 B
16
• Vacuum filling
• Two compartments bobbins
• Self-extinguishing plastics UL 94 VO
• Degree of protection IP 00
• 400 grams weight
• Resin class B CEI 85 (20 000 h testing to CEI 126)
• Fuse protection on secondary side (see diagram) to be assumed
by customer
2 Secondary
windings
8 9
13 14
1 Secondary
winding
8 9
13 14
89
7
7
Primary
winding
1
7
Primary
winding
1
13 14
1
Recommended layout
for transformers with
1 secondary winding
(Allows the use of a
transformer with
2 secondary windings)
EI 48-16,8
PRIMARY VOLTAGE
230 V
EN 60950
• 30 V and 36 V models are VDE EN 61558-2-6 certified
(production on request)
• Insulation voltage 4 KV
• 100 % tested production
• Certification : CCA procedure on request
Primary
protection
mA
Reference
Secondary
voltage
V
Secondary
current
mA
No-load
voltage
V
Ambient
Temperature
°C
Rating
VA
63
44265
6
1667
7,2
T 50 B
10
63
44266
9
1111
10,8
T 50 B
10
63
44267
12
833
14,4
T 50 B
10
63
44268
15
667
18,1
T 50 B
10
63
44269
18
556
21,6
T 50 B
10
63
44270
24
417
28,9
T 50 B
10
63
44271
2x6
2 x 833
2 x 7,2
T 50 B
10
63
44272
2x9
2 x 556
2 x 10,8
T 50 B
10
63
44273
2 x 12
2 x 417
2 x 14,4
T 50 B
10
63
44274
2 x 15
2 x 333
2 x 18,1
T 50 B
10
63
44275
2 x 18
2 x 278
2 x 21,6
T 50 B
10
63
44276*
2 x 24
2 x 208
2 x 28,9
T 50 B
10
*To be noted : 2 x 24 V model is non-approved.
Those transformers meet all requirement of EN 61558-2-4
16 VA
EI 54-18,8
EN 61558-2-6
SERIE 44000
• 30 V and 36 V models are VDE EN 61558-2-6 certified
(production on request)
• Insulation voltage 4 KV
• 100 % tested production
• Certification : CCA procedure on request
*To be noted : 2 x 24 V model is non-approved.
Those transformers meet all requirement of EN 61558-2-4
3.5+0.5
PRIMARY VOLTAGE
230 V
EN 60950
Secondary
protection
mA
Reference
Secondary
voltage
V
Secondary
current
mA
No-load
voltage
V
Ambient
Temperature
°C
Rating
VA
2,500
44301
6
2667
7,4
T 50 B
16
2,000
44302
9
1778
11,1
T 50 B
16
1,25
44303
12
1333
14,7
T 50 B
16
1
44304
15
1067
18,4
T 50 B
16
1
44305
18
889
22,1
T 50 B
16
0,63
44306
24
667
29,3
T 50 B
16
1,25
44307
2x6
2 x 1333
2 x 7,4
T 50 B
16
1
44308
2x9
2 x 889
2 x 11,1
T 50 B
16
0,63
44309
2 x 12
2 x 667
2 x 14,7
T 50 B
16
0,5
44310
2 x 15
2 x 533
2 x 18,4
T 50 B
16
0,5
44311
2 x 18
2 x 444
2 x 22
T 50 B
16
0,315
44312*
2 x 24
2 x 333
2 x 29,3
T 50 B
16
44000 SERIES
EN 61558-2-6
SERIE 44000
ENCAPSULATED TRANSFORMERS
10 VA
17
22 VA
EI 60-21
SERIE 44000
PRIMARY VOLTAGE
117 V
Primary
protection
mA
Reference
Secondary
voltage
V
Secondary
current
mA
No-load
voltage
V
Ambient
Temperature
°C
Rating
VA
250
44444
6
3667
6,8
T 50 B
22
250
44445
9
2444
10,3
T 50 B
22
250
44446
12
1833
13,7
T 50 B
22
250
44447
15
1467
17,1
T 50 B
22
250
44448
18
1222
20,5
T 50 B
22
250
44449
24
917
27,3
T 50 B
22
250
44450
2x6
2 x 1833
2 x 6,8
T 50 B
22
250
44451
2x9
2 x 1222
2 x 10,3
T 50 B
22
250
44452
2 x 12
2 x 917
2 x 13,7
T 50 B
22
250
44453
2 x 15
2 x 733
2 x 17,1
T 50 B
22
250
44454
2 x 18
2 x 611
2 x 20,5
T 50 B
22
250
44455
2 x 24
2 x 458
2 x 27,3
T 50 B
22
30 VA
EI 66-23
44000 SERIES
ENCAPSULATED TRANSFORMERS
2 Secondary
windings
8 9
13 14
1 Secondary
winding
8 9
13 14
8 9
13 14
7
7
Primary
winding
1
7
Primary
winding
1
1
Recommended layout
for transformers
with 1 secondary winding
(Allows the use of a
transformer with 2 secondary
windings)
SERIE 44000
PRIMARY VOLTAGE
117 V
18
• Vacuum filling
• Two compartments bobbins
• Self-extinguishing plastics UL 94 VO
• Degree of protection IP 00
• 550 grams weight
• Resin class B CEI 85 (20 000 h testing to CEI 126)
• Fuse protection on primary side (see diagram) to be assumed
by customer
Primary
protection
mA
Reference
Secondary
voltage
V
Secondary
current
mA
No-load
voltage
V
Ambient
Temperature
°C
Rating
VA
315
44385
6
5000
6,9
T 50 B
30
315
44386
9
3333
10,3
T 50 B
30
315
44387
12
2500
13,8
T 50 B
30
315
44388
15
2000
17,2
T 50 B
30
315
44389
18
1667
20,8
T 50 B
30
315
44390
24
1250
27,7
T 50 B
30
315
44391
2x6
2 x 2500
2 x 6,9
T 50 B
30
315
44392
2x9
2 x 1667
2 x 10,3
T 50 B
30
315
44393
2 x 12
2 x 1250
2 x 13,8
T 50 B
30
315
44394
2 x 15
2 x 1000
2 x 17,2
T 50 B
30
315
44395
2 x 18
2 x 833
2 x 20,8
T 50 B
30
315
44396
2 x 24
2 x 625
2 x 27,7
T 50 B
30
• Vacuum filling
• Two compartments bobbins
• Self-extinguishing plastics UL 94 VO
• Degree of protection IP 00
• 700 grams weight
• Resin class B CEI 85 (20 000 h testing to CEI 126)
• Fuse protection on primary side (see diagram) to be assumed
by customer
2 Secondary
windings
9 10
15 16
1 Secondary
winding
9 10
15 16
9 10
8
8
Primary
winding
1
8
Primary
winding
1
15 16
1
Recommended layout
for transformers
with 1 secondary winding
(Allows the use of a
transformer with 2 secondary
windings)
EI 60-21
PRIMARY VOLTAGE
230 V
EN 60950
• 30 V and 36 V models are VDE EN 61558-2-6 certified
(production on request)
• Insulation voltage 4 KV
• 100 % tested production
• Certification : CCA procedure on request
Primary
protection
mA
Reference
Secondary
voltage
V
Secondary
current
mA
No-load
voltage
V
Ambient
Temperature
°C
Rating
VA
125
44432
6
3667
6,8
T 50 B
22
125
44433
9
2444
10,3
T 50 B
22
*To be noted : 2 x 24 V model is non-approved.
Those transformers meet all requirement of EN 61558-2-4
30 VA
EI 66-23
EN 61558-2-6
125
44434
12
1833
13,7
T 50 B
22
125
44435
15
1467
17,1
T 50 B
22
125
44436
18
1222
20,5
T 50 B
22
125
44437
24
917
27,3
T 50 B
22
125
44438
2x6
2 x 1833
2 x 6,8
T 50 B
22
125
44439
2x9
2 x 1222
2 x 10,3
T 50 B
22
125
44440
2 x 12
2 x 917
2 x 13,7
T 50 B
22
125
44441
2 x 15
2 x 733
2 x 17,1
T 50 B
22
125
44442
2 x 18
2 x 611
2 x 20,5
T 50 B
22
125
44443*
2 x 24
2 x 458
2 x 27,3
T 50 B
22
SERIE 44000
PRIMARY VOLTAGE
230 V
EN 60950
• 30 V and 36 V models are VDE EN 61558-2-6 certified
(production on request)
• Insulation voltage 4 KV
• 100 % tested production
• Certification : CCA procedure on request
*To be noted : 2 x 24 V model is non-approved.
Those transformers meet all requirement of EN 61558-2-4
Primary
protection
mA
Reference
Secondary
voltage
V
Secondary
current
mA
No-load
voltage
V
Ambient
Temperature
°C
Rating
VA
160
44373
6
5000
6,9
T 50 B
30
160
44374
9
3333
10,3
T 50 B
30
160
44375
12
2500
13,8
T 50 B
30
160
44376
15
2000
17,2
T 50 B
30
160
44377
18
1667
20,8
T 50 B
30
160
44378
24
1250
27,7
T 50 B
30
160
44379
2x6
2 x 2500
2 x 6,9
T 50 B
30
160
44380
2x9
2 x 1667
2 x 10,3
T 50 B
30
160
44381
2 x 12
2 x 1250
2 x 13,8
T 50 B
30
160
44382
2 x 15
2 x 1000
2 x 17,2
T 50 B
30
160
44383
2 x 18
2 x 833
2 x 20,8
T 50 B
30
160
44384*
2 x 24
2 x 625
2 x 27,7
T 50 B
30
44000 SERIES
EN 61558-2-6
SERIE 44000
ENCAPSULATED TRANSFORMERS
22 VA
19
BOXES WITH FIXING SUPPORT
SERIE 44000
H
L
P
X
H
L
O
••••• 6
10
6X5.0
•••• •• •
44000 SERIES
ENCAPSULATED TRANSFORMERS
EI 60
1
••••••• 8
14
6X5.0
7
14
1
12
5.0
6X5.0
• ••••••
5X5.0
••••••
6
••••••7
EI 66
1
7
•• •••• • 8
16
Y
± 0,50
7X5.0
••••••••
8
•••••••• 9
CIRCUIT
L
± 0,50
P
± 0,40
H
± 0,40
X
± 0,50
EI 38 X 13,6
55,6
34,9
28,1
47,5
3,2
EI 42 X 14,8
64
37
32,3
55,0
4,2
EI 48 X 16,8
69
42,3
34,6
60
4,2
EI 54 X 18,8
74
47,3
38,8
65
4,2
EI 60 X 21
81,5
53,3
44,7
72,5
43,5
4,2
EI 66 X 23
87,2
58,6
48,5
77,5
47,5
4,2
Ø
±0,3
Series 44000 transformers can be
equiped with boxes with lugs and also
2,8 «faston» terminal tags while still
conforming to the specifications in
the standard references.
• For boxes with 2 lugs and pin type output, add suffix 1 to the reference of the standard transformer (example : 44198-1)
• For boxes with 2 lugs and 2,8 «faston» output, add suffix 2 to the reference of the standard transformer (example : 44199-2)
• For boxes with 4 lugs and pin type output, add suffix 3 to the reference of the standard transformer (example : 44200-3)
• For boxes with 4 lugs and 2,8 «faston» output, add suffix 4 to the reference of the standard transformer (example : 44201-4)
These models are not available on stock.
20
•• • •• 6
10
5.0
EI 54
1
•• • ••
5
11X2.5
1
7.5
7X5.0
•••••
5
EI 48
5X5.0
1
7.5
EI 42
13X2.5
EI 38
5X5.0
4X5.0
X
Y
P
O
1 VA
UI 21
SERIE 45000
• 230 V supply voltage by series/parallel
connection
• Vacuum filling
• One compartiment housing
1 VA
• Two compartments bobbins 0,8 VA
• Degree of protection IP 00
• 50 grams weight
1 VA
• Resin UL 94 VO
• Design protection against short-circuits
• Insulation voltage 4 KV
• 100 % tested production
Conform to EN 61558 - UL 506
PRIMARY VOLTAGE
230 V
Secondary
voltage
V
UI 21
Type 1 VA
2
5
Primary
windings
Secondary
windings
12
7
QUALITY IN SERIES
Secondary
current
mA
No-load
voltage
V
230 V
Ambient
Temperature
°C
1 VA
45001
6
167
11,4
T 70 B
45002
9
111
17
T 70 B
45003
12
83
22,8
T 70 B
45004
15
67
28,5
T 70 B
45005
18
56
34,2
T 70 B
45006
24
42
45,6
T 70 B
45000 SERIES
Reference
ENCAPSULATED TRANSFORMERS
Protection
21
3-10 VA
UI 30
SERIE 45000
PRIMARY VOLTAGE
115 V - 230 V
Protection
Reference
Secondary
voltage
V
Secondary
current
mA
No-load
voltage
V
UI 30 x 5,5
2x6
2 x 167
2 x 10,2
T 70 B
45293
2x9
2 x 111
2 x 15,9
T 70 B
45294
2 x12
2 x 83
2 x 20,4
T 70 B
45295
2 x15
2 x 67
2 x 25,5
T 70 B
45296
2 x18
2 x 56
2 x 30,6
T 70 B
45297
2 x24
2 x 42
2 x 40,8
T 70 B
3 VA
45013
2x6
2 x 250
2 x 9,8
T 70 B
160
45014
2x9
2 x 167
2 x 14,7
T 70 B
125
45015
2 x 12
2 x 125
2 x 19,6
T 70 B
100
45016
2 x 15
2 x 100
2 x 24,5
T 70 B
80
45017
2 x 18
2 x 83
2 x 29,5
T 70 B
63
45018
2 x 24
2 x 63
2 x 39,3
T 70 B
Secondary protection mA
4 VA
315
45019
2x6
2 x 333
2 x 9,4
T 70 B
250
45020
2x9
2 x 222
2 x 14,0
T 70 B
160
45021
2 x 12
2 x 167
2 x 18,6
T 70 B
125
45022
2 x 15
2 x 133
2 x 23,3
T 70 B
125
45023
2 x 18
2 x 111
2 x 28,0
T 70 B
80
45024
2 x 24
2 x 83
2 x 37,4
T 70 B
UI 30 x 10,5
Secondary protection mA
45025
2x6
2 x 500
2 x 8,1
T 70 B
315
45026
2x9
2 x 333
2 x 12,1
T 70 B
250
45027
2 x 12
2 x 250
2 x 16,2
T 70 B
200
45028
2 x 15
2 x 200
2 x 20,2
T 70 B
160
45029
2 x 18
2 x 167
2 x 24,3
T 70 B
125
45030
2 x 24
2 x 125
2 x 32,3
T 70 B
10 VA
Primary protection mA
CIRCUIT
RATING
DIMENSION A
WEIGHT
UI 30 x 5,5
2 VA/3 VA
A = 17 mm
125 g
UI 30 x 7,5
4 VA
A = 19 mm
150 g
UI 30 x 10,5
6 VA
A = 22 mm
185 g
UI 30 x 16,5
10 VA
A = 28 mm
260 g
6 VA
500
UI 30 x 16,5
45000 SERIES
Secondary protection mA
250
UI 30 x 7,5
ENCAPSULATED TRANSFORMERS
2 VA
45292
UI 30 x 5,5
22
Ambient
Temperature
°C
•115 V- 230 V supply voltage
by series/parallel connection
• Vacuum filling
• Two compartments bobbins
• Degree of protection IP 00
• Resin class UL 94 VO
125/63
45031
2x6
2 x 833
2 x 7,9
T 50 B
125/63
45032
2x9
2 x 556
2 x 11,9
T 50 B
125/63
45033
2 x 12
2 x 417
2 x 15,9
T 50 B
125/63
45034
2 x 15
2 x 333
2 x 19,8
T 50 B
125/63
45035
2 x 18
2 x 278
2 x 23,7
T 50 B
125/63
45036
2 x 24
2 x 208
2 x 31,7
T 50 B
•
1
Possible primary
connections
•
230 V
3
5
7
16 14 12 10
•
1
•
Possible secondary
connections
115 V
3
5
7
16 14 12 10
1
3
5
7
16 14 12 10
•
•
Secondary voltage
doubled
QUALITY IN SERIES
1
•
•
3
5
•
•
7
16 14 12 10
Double the
secondary current
SERIE 45000
PRIMARY VOLTAGE
115 V - 230 V
• Fuse protection in secondary winding (see diagram)
• Insulation voltage 4 KV
• 100 % tested production
• Conform to EN 61558
Approval under process
• UL 506 approved
Primary
protection
115 V/230 V
mA
Reference
Secondary
voltage
V
Secondary
current
mA
UI 39 x 8
125/63
45037
2x6
2 x 833
2 x 8,2
T 50 B
125/63
45038
2x9
2 x 555
2 x 12,3
T 50 B
125/63
45039
2 x 12
2 x 416
2 x 16,4
T 50 B
125/63
45040
2 x 15
2 x 333
2 x 20,5
T 50 B
125/63
45041
2 x 18
2 x 277
2 x 24,6
T 50 B
125/63
45042
2 x 24
2 x 208
2 x 32,8
T 50 B
14 VA
160/80
45043
2x6
2 x 1167
2 x 7,5
T 50 B
160/80
45044
2x9
2 x 778
2 x 10,9
T 50 B
160/80
45045
2 x 12
2 x 583
2 x 15,0
T 50 B
160/80
45046
2 x 15
2 x 467
2 x 18,7
T 50 B
160/80
45047
2 x 18
2 x 389
2 x 22,4
T 50 B
160/80
45048
2 x 24
2 x 292
2 x 30,2
T 50 B
UI 39 x 13,5
RATING
DIMENSION A
WEIGHT
UI 39 x 8
10 VA
A = 22 mm
285 g
UI 39 x 10,2
14 VA
A = 24 mm
335 g
UI 39 x 13,5
18 VA
A = 27 mm
405 g
UI 39 x 17
24 VA
A = 31 mm
480 g
UI 39 x 21
30 VA
A = 35 mm
550 g
18 VA
200/100
45049
2x6
2 x 1500
2 x 7,4
T 50 B
200/100
45050
2x9
2 x 1000
2 x 11,0
T 50 B
200/100
45051
2 x 12
2 x 750
2 x 14,7
T 50 B
200/100
45052
2 x 15
2 x 600
2 x 18,3
T 50 B
200/100
45053
2 x 18
2 x 500
2 x 22,0
T 50 B
200/100
45054
2 x 24
2 x 375
2 x 29,4
T 50 B
UI 39 x 17
•
1
Possible primary
connections
•
230 V
4
6
9
•
1
••
Possible secondary
connections
115 V
4
6
9
19 17
14 12
19 17
14 12
sec 1
sec 2
sec 1
sec 2
•• ••
•• ••
1
4
19 17
•
6
9
14 12
•
Secondary voltage
doubled
1
4
••
19 17
6
9
•
•
14 12
Double the
secondary current
Ambient
Temperature
°C
10 VA
UI 39 x 10,2
CIRCUIT
No-load
voltage
V
24 VA
250/125
45055
2x6
2 x 2000
2 x 7,1
T 50 B
250/125
45056
2x9
2 x 1333
2 x 10,6
T 50 B
250/125
45057
2 x 12
2 x 1000
2 x 14,1
T 50 B
250/125
45058
2 x 15
2 x 800
2 x 17,6
T 50 B
250/125
45059
2 x 18
2 x 667
2 x 21,2
T 50 B
250/125
45060
2 x 24
2 x 500
2 x 28,3
T 50 B
UI 39 x 21
30 VA
315/160
45061
2x6
2 x 2500
2 x 6,7
T 50 B
315/160
45062
2x9
2 x 1667
2 x 10,15
T 50 B
315/160
45063
2 x 12
2 x 1250
2 x 13,5
T 50 B
315/160
45064
2 x 15
2 x 1000
2 x 16,8
T 50 B
315/160
45065
2 x 18
2 x 833
2 x 20,2
T 50 B
315/160
45066
2 x 24
2 x 625
2 x 27,0
T 50 B
45000 SERIES
UI 39
ENCAPSULATED TRANSFORMERS
10-30 VA
23
40-60 VA
UI 48
SERIE 45000
• 115 V- 230 V supply voltage
by series/parallel connection
• Vacuum filling
• Two compartments bobbins
• Degree of protection IP 00
• Resin class UL 94 VO
• Fuse protection in secondary winding (see diagram)
• Insulation voltage 4 KV
• 100 % tested production
• Conform to EN 61558
Approval under process
• UL 506 approved
PRIMARY VOLTAGE
115 V - 230 V
Primary
protection
115/230 V
mA
Reference
Secondary
voltage
V
Secondary
current
mA
U I 48 x 17
Ambient
Temperature
°C
40 VA
400/200
45067
2x6
2 x 3333
2 x 6,7
T 50 B
400/200
45068
2x9
2 x 2222
2 x 10,0
T 50 B
400/200
45069
2 x 12
2 x 1667
2 x 13,4
T 50 B
400/200
45070
2 x 15
2 x 1333
2 x 16,7
T 50 B
400/200
45071
2 x 18
2 x 1111
2 x 20,1
T 50 B
400/200
45072
2 x 24
2 x 833
2 x 26,8
T 50 B
U I 48 x 26
60 VA
630/315
45073
2x6
2 x 5000
2 x 6,6
T 50 B
630/315
45074
2x9
2 x 3333
2 x 9,9
T 50 B
630/315
45075
2 x 12
2 x 2500
2 x 13,1
T 50 B
630/315
45076
2 x 15
2 x 2000
2 x 16,4
T 50 B
UI 48 x 17
40 VA
38,5 13,5 83
760 g
630/315
45077
2 x 18
2 x 1667
2 x 19,7
T 50 B
UI 48 x 26
60 VA
48,5 14,5 86
1060 g
630/315
45078
2 x 24
2 x 1250
2 x 26,3
T 50 B
CIRCUIT
RATING
Possible primary
connections
•
230 V
1
4
23
45000 SERIES
ENCAPSULATED TRANSFORMERS
No-load
voltage
V
24
9
20
17
•
12
14
•
•
115 V
1
4
23
9
20
17
A
•
•
12
14
B
C
WEIGHT
Possible secondary
connections
1
4
23
•
9
20
17
12
14
•
Secondary voltage
doubled
QUALITY IN SERIES
1
4
23
•
•
9
20
17
12
•
•
14
Double the
secondary current