PAULSTRADYN®
w
Ne
!
Natural frequency :
• axial 7 Hz
• radial 3 to 5.5 Hz
ADVANTAGES
•Better
than 90% isolation at 1.500 rpm
(25 Hz).
•Constant height over wide load range.
•Stabilised characteristics during Service Life.
•Simple to fit.
•400 hours protection against salt spray*.
•Design.
* When mounted according to the recommendations given in
the catalogue.
Finite element modeling
New formula SILTECH
- Low increase of stiffness with frequency
- Low creep
38
APPLICATIONS
Anti vibration isolation for static equipment :
- rotating machinery such as fans, air-conditioning, pumps, compressors, generator sets.
- pipework, ceilings, transformers, electrical enclosures.
DIMENSIONS
Fig. 1
ØA
ØI
B
N
ØC
E
G
ØA
E
Fig. 2
H
J
G
ØI
N
ØC
B
D
J
F
Designation
Ref.
Paulstradyn
4 533701
7 533702
12 533703
Paulstradyn 20 533704
30 533705
50 533706
Paulstradyn 70 533707
100 533708
130 533709
Paulstradyn
Paulstradyn
Paulstradyn
160
200
260
325
400
500
640
820
1050
1350
Nominal
load
Fig.
ØA
NL (daN)
Dimensions (mm)
B*
ØC
D
E
F
G
H
ØI
J
N
4
7
12
1
40
40
M6
52
6.2
64
6.2
44
12
2.5
6
20
30
50
2
60
40
M6
76
6.2
90
8.2
64
32
2.5
6
70
100
130
2
80
40
M8
100
8.2
122
12.2
84
48
2.5
12
533710
533711
533712
160
200
260
2
100
40
M10
124
10.2
152
16.2
104
68
3
10
533713
533714
533715
533716
533717
533718
533719
325
400
500
640
820
1050
1350
2
150
40
M12
182
12.2
214
20.2
154
116
4.5
10
2
200
40
M16
240
14.2
280
24.2
204
159
5.5
20
* : Height, unloaded 40 mm, under load 32 mm (see Technical Characteristics).
NL : Nominal static load with mounting under axial compression.
39
TECHNICAL CHARACTERISTICS
The vibration attenuation and height characteristics under nominal load are stabilised after one
month under load at 20°C.
• Natural axial frequency 7 Hz, with nominal load.
• Natural radial frequency 3 to 5.5 Hz.
• Maximum displacement :
Common characteristics
- axial : 12 mm.
- radial : ± 10 mm.
Vibration attenuation
Rotating speed (rpm)
900
1500
2100
2700
3300
3900
4500
5100
5700
20
90
AL
=1
NL
AL
= 0.8
NL
AL
= 0.9
NL
AL
= 0.7
NL
80
70
14
10
80
60
50
AL
Actual load
____
= Ratio _______________
NL
Nominal load
Attenuation (dB)
Attenuation coefficient (%)
100
10
20
30
40
50
60
70
80
90
60
100
Excitation frequency (Hz)
Height under load
Temperature
Operating temperature : - 20°C to + 70°C.
Other characteristics*
• Good dynamic performance at high frequency.
• Withstands fatigue and shocks.
• Reduced creep.
* Detailed Technical Characteristics can be sent on request. Ask
us for details.
40
MOUNTING
Standard mounting
① machine base or foot
dimensions > Ø M*
② supporting structure (floor)
dimensions > base of mounting F x H* (refer
page 39)
③ screw Ø C**
④ screw Ø K, a washer is required between the screw
head and the PAULSTRADYN*
⑤ screw Ø K, a washer is required between the
screw head and the PAULSTRADYN*
Note : * to ditribute the load and resist corrosion
** nuts and screws grade 4.6 minimum.
ON CONCRETE
ON CHASSIS
Fig. 1
Recommended torque
Diameter K
M6
M8
(mm)
torque
5
2
N.m.
Note : Do not paint the mountings after fitting.
Alternative mounting
41
M10
M12
12
20
很抱歉,暂时无法提供与“533711”相匹配的价格&库存,您可以联系我们找货