Switches & Pilot Devices
ø22mm - HW Series
Switches & Pilot Devices
HW Series — 22mm IEC Style Global Pushbuttons
Key features:
Signaling Lights
• Locking lever removable contact blocks
• Finger-safe IP20 contacts as standard, other terminal
styles available
• Tamperproof construction
• All E-stops meet EN418 and are compliant with
SEMI S2 standards
• Worldwide approvals
• Easy to assemble
• Choice of black plastic or metallic front bezels
• Incandescent or LED illumination
• Transformer or full voltage
• Slow make double break self cleaning contacts
HW: The Best Engineered Switch in the World
Complete with finger-safe contact blocks offering IP20 protection, these 7/8”
(22mm) switches include illuminated and non-illuminated pushbuttons, pilot
All switches also incorporate mechanically keyed safety locking levers, ensuring
correct installation and maintaining safety in high-vibration applications.
Registration No. R9551089 (E-stops)
Registration No. R50054316 (Dual Pushbuttons)
Registration No. J9650511 (Pilot Lights)
Registration No. J9551458 (all other switches)
®
File No. E68961
lights, selector switches, and emergency stop switches.
Certificate No.
2005010305145656
File No. LR92374
Maximum Inrush Current
40 A (40 ms)
Rated Insulation Voltage
600V
Rated Switching Over-Voltage
Less than 4kV, conforming to IEC60947-1
Rated Impulse Withstanding Voltage
4kV for contact circuit, 2.5kV for lamp circuit
Rated Thermal Current
10 Amp
Minimum Switching Capacity
5 mA at 3V AC/DC
Electrical Reliability
MTBF < 1 fault for 10 million operation cycles (3V DC, 5mA)
Lamp Ratings
Incandescent: 1 W
LEDs: 6V/17mA max, 12V & 24V/11mA max, 120 & 240V/10mA max
Contactors
Rated Operational Characteristics
AC-15: A600 or Ue = 250V, le = 3A (NO, NC, NO-EM, NC-LB)
DC-13: P600 or Ue = 125V, le = 1.1A (NO, NC)
DC-13: Q600 or Ue = 125V, le = 0.9A (NO-EM, NC-LB)
Timers
Specifications
Electrical
Relays & Sockets
IDEC’s HW switches are “The best engineered switch in the world” for a
reason. Carrying the CE mark, UL, CSA, CCC (Chinese), and TUV approvals, these
switches are designed for use in almost any part of the world.
Terminal Blocks
Circuit Breakers
800-262-IDEC (4332) • USA & Canada
549
Switches & Pilot Devices
Mechanical
Contact Operation
Slow break NC or NO, self-cleaning
Positive Action Operation
(Emergency Stops with NC contacts)
5.5mm to 10mm travel to latch, 45N minimum force to latch
10mm maximum travel, 1,800 operations per hour maximum for a Pushlock Turn Reset
900 operations per hour maximum for a Push-Pull
Operating Force
Flush and extended pushbuttons—with 1NO or 1NC contact: 6.2±2N (momentary), 7.0±2N (maintained)
Additional contacts—1NO or 1NC: +3.2N (momentary), + 3.3N (maintained)
Recommended Terminal Torque
0.8 N m (7.1 in lb.)
Applicable Wire Size
Minimum 1 x 22 AWG, max. 2 x 14 AWG or 1 x 12 AWG
Contact Resistance
Initial contact resistance of 50mΩ or less
Contact Gap
4mm (NO and NC), 2mm (NO-EM and NC-LB)
Horsepower Rating
Reference Value: 1/4 HP @ 120V (1ø non-reversing), 1HP @ 240V (3ø non-reversing)
Contact Material
Silver (gold plated contacts available - contact IDEC)
Operating Temperature
Operation: –25 to +50°C (without freezing), Storage: –40 to +70°C (without freezing)
Vibration Resistance
10 to 55Hz, 98m/sec2 (10G) conforming to IEC6068-2-6
Shock Resistance
980m/sec2 (100G) conforming to IEC6068-2-7
Mechanical Life
Momentary pushbuttons: 5,000,000 (900 operations per hour), All other switches: 500,000
Conforming to Standards
EN60947-1, EN60947-5-1, VDE0660-200, UL508, CSA C22-2 No.14
Approvals
®
File No. E68961
Standards & Approvals
Timers
Relays & Sockets
Signaling Lights
Switches & Pilot Devices
ø22mm - HW Series
File No. LR92374
Registration No. R9551089 (E-stops)
Registration No. R50054316 (Dual Pushbuttons)
Registration No. J9650511 (Pilot Lights)
Registration No. J9551458 (all other switches)
Electric Shock Protection
Class 0 conforming to IEC60536
Degree of Protection
(conforming to IEC60529)
(conforming to NEMA ICS6-110)
IP65 (from front of the panel)
IP20 (Type HW-F contact block)
NEMA 1, 2, 3, 3R, 3S, 4, 4X, 5, 12, 13 (from front of panel)
Pollution Degree (conforming to IEC60947-1)
3 for switches not using a transformer, 2 for switches using a transformer
External Short-Circuit Protection
10A 250V fuse conforming to IEC60269-1
Contact Ratings
Characteristics
Contactors
Terminal Referencing
Terminal Blocks
Certificate No.
2005010305145656
CSA: pushbuttons and selector switches: A600
pilot lights and illuminated pushbuttons, direct supply pilot lights and illuminated pushbuttons with
integral transformer (100/110, 115, 120, 200/220, 230, 240, 380, 400/440, 480V)
UL: pushbuttons and selector switches: A600
pilot lights and illuminated pushbuttons, direct supply pilot lights and illuminated pushbuttons with
integral transformer (100/110, 115, 120, 200/220, 230, 240, 380, 400/440, 480V)
TÜV: pushbuttons and selector switches: A600=P600 (NO, NC)/Q600 (NO-EM, NC-LB)
pilot lights and illuminated pushbuttons, direct supply pilot lights and illuminated pushbuttons with
integral transformer (100/110, 115, 120, 200/220, 230, 240, 380, 400/440, 480V)
Pushbuttons
Illuminated Pushbuttons
Selector Switches
Illuminated Selector Switches
Pushbutton Selectors
Conforming to CENELEC EN50005
Contact Block
Type HW-C/HW-F /HW-G
Rated Insulation Voltage
600V
Rated Continuous Current
10A
Contact Ratings by Utilization Category
IEC 60947-5-1
AC-15 (A600)
DC-13 (P600)
Operational Voltage
Operational
Current
AC 50/60 Hz
DC
AC-12 Control of resistive loads & solid state loads
24V
48V
50V
110V
220V
440V
10A
—
10A
10A
6A
2A
AC-15 Control of electromagnetic loads (> 72VA)
10A
—
7A
5A
3A
1A
DC-12 Control of resistive loads & solid state loads
8A
5A
—
2.2A
1.1A
—
DC-13 Control of electromagnets
5A
2A
—
1.1A
0.6A
—
Circuit Breakers
For dimensions, see page 601.
550
www.IDEC.com
Switches & Pilot Devices
ø22mm - HW Series
Switches & Pilot Devices
LED Lamp Ratings (LSTD Type)
Model
LSTD-6k
LSTD-1k
LSTD-2k
LSTD-H2k
LSTD-M4k
Rated Voltage
6V AC/DC
12V AC/DC
24V AC/DC
120V AC
240V AC
Voltage Range
6V AC/DC ±10%
12V AC/DC ±10%
24V AC/DC ±10%
120V AC ±5%
240V AC
±5%
Lamp Base
Current
Draw
BA9S/13
A, R, W:
G, S:
17mA
8mA
11mA
11mA
10mA
10mA
DC
A, R, W:
G, S:
14mA
5.5mA
10mA
10mA
–
–
Color Code
A (amber), G (green), R (red), S (blue), W (white)
Lamp Base Color
Same as illumination color
Voltage Marking
Life (reference value)
Die stamped on the base
Approx. 50,000 hours (The luminance reduces to 50% the initial intensity when used on complete DC.)
A, R, W
A, R, W
In place of k,
specify the Lens/LED
Color Code.
Relays & Sockets
Internal Circuit
Signaling Lights
AC
G, S
LED Chip
LED Chip
LED Chip
Protection Diode
Protection
Protection
DiodeDiode
Zener Diode Zener Diode
Zener Diode
Timers
Contactors
Terminal Blocks
Circuit Breakers
800-262-IDEC (4332) • USA & Canada
551
Switches & Pilot Devices
Switches & Pilot Devices
ø22mm - HW Series
Contactors
Timers
Relays & Sockets
Signaling Lights
Non-Illuminated Round Pushbuttons (Assembled)
Round Flush
Function
Contacts
Momentary
Maintained
Plastic Bezel
Terminal Blocks
Plastic Bezel
Operator Only
HW1B-M1-j
HW4B-M1-j
HW1B-M2-j
HW4B-M2-j
HW1B-M1F10-j
HW4B-M1F10-j
HW1B-M2F10-j
HW4B-M2F10-j
1NC
HW1B-M1F01-j
HW4B-M1F01-j
HW1B-M2F01-j
HW4B-M2F01-j
1NO-1NC
HW1B-M1F11-j
HW4B-M1F11-j
HW1B-M2F11-j
HW4B-M2F11-j
2NO
HW1B-M1F20-j
HW4B-M1F20-j
HW1B-M2F20-j
HW4B-M2F20-j
2NC
HW1B-M1F02-j
HW4B-M1F02-j
HW1B-M2F02-j
HW4B-M2F02-j
2NO-2NC
HW1B-M1F22-j
HW4B-M1F22-j
HW1B-M2F22-j
HW4B-M2F22-j
Operator Only
HW1B-A1-j
HW4B-A1-j
HW1B-A2-j
HW4B-A2-j
1NO
HW1B-A1F10-j
HW4B-A1F10-j
HW1B-A2F10-j
HW4B-A2F10-j
1NC
HW1B-A1F01-j
HW4B-A1F01-j
HW1B-A2F01-j
HW4B-A2F01-j
1NO-1NC
HW1B-A1F11-j
HW4B-A1F11-j
HW1B-A2F11-j
HW4B-A2F11-j
2NO
HW1B-A1F20-j
HW4B-A1F20-j
HW1B-A2F20-j
HW4B-A2F20-j
2NC
HW1B-A1F02-j
HW4B-A1F02-j
HW1B-A2F02-j
HW4B-A2F02-j
2NO-2NC
HW1B-A1F22-j
HW4B-A1F22-j
HW1B-A2F22-j
HW4B-A2F22-j
Color
Code
Black
B
Green
G
Red
R
Blue
S
White
W
Yellow
Y
1. In place of j, specify the Button Color Code from table below.
2. For nameplates and accessories, see page 596 and 599.
3. For dimensions, see page 601.
4. For contact assembly part numbers, see page 600.
5. All assembled part numbers in catalog include standard, fingersafe (HW-F...)
contacts.
6. Assembled units with spring-up terminals (HW-G...) can be ordered by
removing an “F” from the part number (Ex. HW1B-M1F11-R becomes
HW1B-M111-R).
7. Operator only models include operator plus button.
8. Additional contact configurations available (up to 6 total contacts).
N*
Circuit Breakers
*Gray available for round flush only.
552
Metal Bezel
1NO
j Button Color Code
Gray
Round Extended
Metal Bezel
www.IDEC.com
Switches & Pilot Devices
ø22mm - HW Series
Switches & Pilot Devices
Part Number Structure
H
W
1
B
-
M
1
F
10 – R
Button Colors
Bezel
1: Plastic Bezel
4: Metal Bezel
Function
Contact Arrangement
Operator
M: Momentary Action
A: Maintained Action
Terminals
1: Flush
2: Extended
20: 2NO
02: 2NC
22: 2NO-2NC
Signaling Lights
F: Fingersafe Contacts
C: Exposed Screw Terminals
blank: Spring-up Terminals
10: 1NO
01: 1NC
11: 1NO-NC
B: Black
G: Green
R: Red
S: Blue
W: White
Y: Yellow
N: Gray*
*Available for round
flush only
Non-Illuminated Round Pushbuttons (Replacement Parts)
+
Mounting Adaptor
+
Safety
Lever Lock
Contacts
Spring-Up
Terminal
Anti-Rotation Ring
1NO
1NC
HW-F10
HW-F01
HW-F10R
(early make)
HW-F01R
(late break)
HW-G10
HW-G01
HW-G10R
(early make)
HW-G01R
(late break)
HW-C10
HW-C01
HW-C10R
(early make)
HW-C01R
(late break)
Dummy
Block
Part Number
Completed Unit
Style
Part Number
HW9Z-RL
HW1A-B1-j
Use with notched panel cutout to prevent
unit rotation.
Round Extended
Operators
HW1A-B2-j
Plastic
Bezel
Style
Round Flush/
Extended
Metal
Bezel
1. In place of j, specify the
Button Color Code from table.
HW1B-M0
HW4B-MO
j Button Color Code
HW1B-A0
Safety Lever Lock
Style
HW4B-AO
Color
Code
Color
Code
Black
B
White
W
Green
G
Yellow
Y
Red
R
Gray
N*
Blue
S
Terminal Blocks
Part Number
*Gray available for round flush
only.
Part Number
HW9Z-LS
800-262-IDEC (4332) • USA & Canada
Circuit Breakers
1. Used to mount contact blocks to operator.
2. IDEC strongly recommends using the safety lever
lock to prevent heavy vibration or maintenance
personnel from inadvertently unlocking contacts.
=
Round Flush
TW-DB
HW-CB2C
Button
Buttons
Style
Contact Block Mounting Adaptor
Style
+
Contactors
Exposed
Screw
Terminal
Operator
Timers
Standard
Fingersafe
(IP20)
+
Maintained
Style
Anti-Rotation
Ring
Relays & Sockets
Contact Blocks
+
Momentary
Contact Blocks
553
Switches & Pilot Devices
Switches & Pilot Devices
ø22mm - HW Series
Relays & Sockets
Signaling Lights
Non-Illuminated Mushroom Head Pushbuttons (Assembled)
ø29mm Mushroom Head
Function
Timers
Momentary
Contactors
Maintained
ø40mm Mushroom Head
Contacts
Plastic Bezel
Metal Bezel
Plastic Bezel
Metal Bezel
Operator Only
HW1B-M3-j
HW4B-M3-j
HW1B-M4-j
HW4B-M4-j
1NO
HW1B-M3F10-j
HW4B-M3F10-j
HW1B-M4F10-j
HW4B-M4F10-j
1NC
HW1B-M3F01-j
HW4B-M3F01-j
HW1B-M4F01-j
HW4B-M4F01-j
1NO-1NC
HW1B-M3F11-j
HW4B-M3F11-j
HW1B-M4F11-j
HW4B-M4F11-j
2NO
HW1B-M3F20-j
HW4B-M3F20-j
HW1B-M4F20-j
HW4B-M4F20-j
2NC
HW1B-M3F02-j
HW4B-M3F02-j
HW1B-M4F02-j
HW4B-M4F02-j
2NO-2NC
HW1B-M3F22-j
HW4B-M3F22-j
HW1B-M4F22-j
HW4B-M4F22-j
Operator Only
HW1B-A3-j
HW4B-A3-j
HW1B-A4-j
HW4B-A4-j
1NO
HW1B-A3F10-j
HW4B-A3F10-j
HW1B-A4F10-j
HW4B-A4F10-j
1NC
HW1B-A3F01-j
HW4B-A3F01-j
HW1B-A4F01-j
HW4B-A4F01-j
1NO-1NC
HW1B-A3F11-j
HW4B-A3F11-j
HW1B-A4F11-j
HW4B-A4F11-j
2NO
HW1B-A3F20-j
HW4B-A3F20-j
HW1B-A4F20-j
HW4B-A4F20-j
2NC
HW1B-A3F02-j
HW4B-A3F02-j
HW1B-A4F02-j
HW4B-A4F02-j
2NO-2NC
HW1B-A3F22-j
HW4B-A3F22-j
HW1B-A4F22-j
HW4B-A4F22-j
Terminal Blocks
j Button Color
Code
Function
Circuit Breakers
Momentary
554
Color
Code
ø60mm Mushroom Head
Black
B
Contacts
Plastic Bezel
Green
G
Operator Only
HW1B-M5-j*
Red
R
1NO
HW1B-M5F10-j*
Blue
S
1NC
HW1B-M5F01-j*
White
W
1NO-1NC
HW1B-M5F11-j*
2NO
HW1B-M5F20-j*
Yellow
Y
2NC
HW1B-M5F02-j*
2NO-2NC
HW1B-M5F22-j*
www.IDEC.com
1. In place of j, specify the Button Color Code from table.
2. *60mm mushroom available only in red, green, black, and yellow.
3. For nameplates and accessories, see page 596 and 599.
4. For dimensions, see page 601.
5. For contact assembly part numbers, see page 600.
6. All assembled part numbers in catalog include standard fingersafe
(HW-F...) contacts.
7. Assembled units with spring-up terminals (HW-G...) can be ordered
by removing an “F” from the part number (Ex. HW1B-M1F11-R
becomes HW1B-M111-R).
8. Units with exposed screw terminals (HW-C...) must be ordered as
sub-components.
9. Operator only models include operator plus button.
10. Additional contact configurations available (up to 6 total contacts).
Switches & Pilot Devices
ø22mm - HW Series
Switches & Pilot Devices
Part Number Structure
H
W
1
B
-
M
3
F
10 – R
Button Colors
Bezel
1: Plastic Bezel
4: Metal Bezel
Function
Contact Arrangement
Operator
M: Momentary Action
A: Maintained Action
(Not available for 60mm
mushroom)
Terminals
F: Fingersafe Contacts
C: Exposed Screw Terminals
blank: Spring-up Terminals
10: 1NO
01: 1NC
11: 1NO-NC
20: 2NO
02: 2NC
22: 2NO-2NC
Signaling Lights
3: ø29mm Mushroom
4: ø40mm Mushroom
5: ø60mm Mushroom
(Not available for 60mm jumbo
mushroom pushbutton.)
B: Black
G: Green
R: Red
S: Blue
W: White
Y: Yellow
Non-Illuminated Mushroom Head Pushbuttons (Replacement Parts)
+
Mounting
Adaptor
+
Safety Lever
Lock
Style
Contacts
Standard
Fingersafe
(IP20)
Operator
+
Button
Safety Lever Lock
1NO
1NC
HW-F10
HW-F01
HW-F10R
(early make)
HW-F01R
(late break)
HW-G10
HW-G01
HW-G10R
(early make)
HW-G01R
(late break)
HW-C10
HW-C01
HW-C10R
(early make)
Dummy
Block
HW-C01R
(late break)
TW-DB
Style
Part Number
Style
HW9Z-LS
ø29mm
Mushroom Cap
Part Number
HW1A-B3-j
Anti-Rotation Ring
Appearance
Part Number
ø40mm
Mushroom Cap
HW9Z-RL
HW1A-B4-j
Operators
Style
Plastic Bezel
ø29mm Mushroom
ø40mm Mushroom
HW1B-M0L
Metal
Bezel
HW4B-MOL
HW1B-M5-j*
HW4B-AOL
j Button Color Code
Color
Code
Color
Code
Black
B
Blue
S
Green
G
White
W
R
Yellow
Y
Red
HW1B-M5 available only in black,
red, green and yellow.
–
Circuit Breakers
Maintained
Ø60mm Jumbo
Mushroom
Momentary
HW-CB2C
HW1B-A0L
1. In place of j, specify the Button
Color Code from table.
Terminal Blocks
Part Number
1. Used to mount contact blocks to operator.
2. IDEC strongly recommends using the
safety lever lock to prevent heavy vibration
or maintenance personnel from inadvertently unlocking contacts.
Completed Unit
Buttons
Contact Block Mounting Adaptor
Style
=
Contactors
Exposed
Screw
Terminal
+
Timers
Spring-Up
Terminal
Anti-Rotation
Ring
Relays & Sockets
Contact Blocks
+
Momentary
Contact Blocks
1. *60mm mushroom operator includes non-removable button
(available in red, black, green and yellow only).
2. For nameplates and accessories, see page 596 and 599.
3. For dimensions, see page 601.
800-262-IDEC (4332) • USA & Canada
555
Switches & Pilot Devices
Switches & Pilot Devices
ø22mm - HW Series
Relays & Sockets
Signaling Lights
Non-Illuminated Square Pushbuttons (Assembled)
Function
Timers
Momentary
Contactors
Maintained
Square Extended
Plastic Bezel
Plastic Bezel
Operator Only
HW2B-M1-j
HW2B-M2-j
1NO
HW2B-M1F10-j
HW2B-M2F10-j
1NC
HW2B-M1F01-j
HW2B-M2F01-j
1NO-1NC
HW2B-M1F11-j
HW2B-M2F11-j
2NO
HW2B-M1F20-j
HW2B-M2F20-j
2NC
HW2B-M1F02-j
HW2B-M2F02-j
2NO-2NC
HW2B-M1F22-j
HW2B-M2F22-j
Operator Only
HW2B-A1-j
HW2B-A2-j
1NO
HW2B-A1F10-j
HW2B-A2F10-j
1NC
HW2B-A1F01-j
HW2B-A2F01-j
1NO-1NC
HW2B-A1F11-j
HW2B-A2F11-j
2NO
HW2B-A1F20-j
HW2B-A2F20-j
2NC
HW2B-A1F02-j
HW2B-A2F02-j
2NO-2NC
HW2B-A1F22-j
HW2B-A2F22-j
j Button Color Code
Color
Code
Black
B
Green
G
Red
R
Blue
S
White
W
Yellow
Y
1. In place of j, specify the Button Color Code from table.
2. For nameplates and accessories, see page 596 and 599.
3. For dimensions, see page 601.
4. For contact assembly part numbers, see page 600.
5. Square pushbuttons available in plastic bezel only.
6. All assembled part numbers in catalog include standard fingersafe (HW-F...) contacts.
7. Assembled units with spring-up terminals (HW-G...) can be ordered by removing an
“F” from the part number (Ex. HW2B-M1F11-R becomes HW1B-M111-R).
8. Units with exposed screw terminals (HW-C...) must be ordered as sub-components.
9. Operator only model includes operator and button.
10. Additional contact configurations available (up to 6 total contacts).
Circuit Breakers
Terminal Blocks
Square Flush
Contacts
556
www.IDEC.com
Switches & Pilot Devices
ø22mm - HW Series
Switches & Pilot Devices
Part Number Structure
H
W
2
B
-
M
1
F
10 – R
Button Colors
Function
M: Momentary Action
A: Maintained Action
Contact Arrangement
Operator
1: Flush
2: Extended
10: 1NO
01: 1NC
11: 1NO-NC
Terminals
Signaling Lights
F: Fingersafe Contacts
C: Exposed Screw Terminals
blank: Spring-up Terminals
20: 2NO
02: 2NC
22: 2NO-2NC
B: Black
G: Green
R: Red
S: Blue
W: White
Y: Yellow
Non-Illuminated Square Pushbuttons (Replacement Parts)
Contact Blocks
Mounting
Adaptor
+
+
Safety
Lever Lock
+
Anti-Rotation
Ring
+
Operator
+
Button
=
Completed Unit
Relays & Sockets
Contact Blocks
Style
Contacts
Spring-Up
Terminal
1NO
1NC
HW-F10
HW-F01
HW-F10R
(early make)
HW-F01R
(late break)
HW-G10
HW-G01
HW-G10R
(early make)
HW-G01R
(late break)
Style
Buttons
Part Number
Style
Part Number
Square Flush
HW9Z-LS
HW2A-B1-j
Anti-Rotation Ring
Appearance
Part Number
Square Extended
HW2A-B2-j
HW9Z-RL
HW-C10
HW-C01
HW-C10R
(early make)
HW-C01R
(late break)
Style
Part Number
Plastic
Bezel
Style
Square Flush
Extended
HW-CB2C
HW2B-A0
j Button Color Code
Color
Code
Color
Code
Black
B
Blue
S
Green
G
White
W
Red
R
Yellow
Y
2. For nameplates and accessories, see
pages 596 and 599.
3. For dimensions, see page 601.
800-262-IDEC (4332) • USA & Canada
Circuit Breakers
1. Used to mount contact blocks to operator.
2. IDEC strongly recommends using the safety
lever lock to prevent heavy vibration or
maintenance personnel from inadvertently
unlocking contacts.
HW2B-M0
1. In place of j, specify the Button
Color Code from table.
Terminal Blocks
Contact Block Mounting Adaptor
Operators
Momentary
TW-DB
Use with notched panel cutout to
prevent unit rotation.
Maintained
Dummy
Block
Contactors
Exposed
Screw
Terminal
Timers
Standard
Fingersafe
(IP20)
Safety Lever Lock
557
Switches & Pilot Devices
Switches & Pilot Devices
ø22mm - HW Series
Ø29mm Head Pushlock Turn Reset
Ø40mm Head Pushlock Turn Reset
Contacts
Plastic Bezel
Metal Bezel
Plastic Bezel
Metal Bezel
Operator Only
HW1B-V3j†
HW4B-V3j†
HW1B-V4j†
HW4B-V4j†
1NO
HW1B-V3F10-j†
HW4B-V3F10-j†
HW1B-V4F10-j†
HW4B-V4F10-j†
1NC
HW1B-V3F01-j†
HW4B-V3F01-j†
HW1B-V4F01-j†
HW4B-V4F01-j†
1NO-1NC
HW1B-V3F11-j†
HW4B-V3F11-j†
HW1B-V4F11-j†
HW4B-V4F11-j†
2NO
HW1B-V3F20-j†
HW4B-V3F20-j†
HW1B-V4F20-j†
HW4B-V4F20-j†
2NC
HW1B-V3F02-j†
HW4B-V3F02-j†
HW1B-V4F02-j†
HW4B-V4F02-j†
Timers
Relays & Sockets
Signaling Lights
Non-Illuminated E-Stop Pushbuttons (Assembled)
Contacts
Plastic Bezel
Metal Bezel
Plastic Bezel
Metal Bezel
HW1B-V4R-EMO-2*
HW4B-V4R-EMO-2*
HW1B-X4R*
HW4B-X4R*
1NO
HW1B-V4F10-R-EMO-2*
HW4B-V4F10-R-EMO-2*
HW1B-X4F10-R*
HW4B-X4F10-R*
1NC
HW1B-V4F01-R-EMO-2*
HW4B-V4F01-R-EMO-2*
HW1B-X4F01-R*
HW4B-X4F01-R*
1NO-1NC
HW1B-V4F11-R-EMO-2*
HW4B-V4F11-R-EMO-2*
HW1B-X4F11-R*
HW4B-X4F11-R*
2NO
HW1B-V4F20-R-EMO-2*
HW4B-V4F20-R-EMO-2*
HW1B-X4F20-R*
HW4B-X4F20-R*
2NC
HW1B-V4F02-R-EMO-2*
HW4B-V4F02-R-EMO-2*
HW1B-X4F02-R*
HW4B-X4F02-R*
ø60mm Head Pushlock Turn Reset
Circuit Breakers
Ø40mm Head Pushlock Key Reset
Operator Only
Terminal Blocks
Contactors
Ø40mm Head EMO Pushlock Turn Reset
Contacts
Plastic Bezel
Operator Only
HW1B-V5R*
1NO
HW1B-V5F10-R*
1NC
HW1B-V5F01-R*
1NO-1NC
HW1B-V5F11-R*
2NO
HW1B-V5F20-R*
2NC
HW1B-V5F02-R*
558
1. * Available in Red only.
2. † Available in red or yellow. Insert color code in place of j (R: Red, Y: Yellow).
2. For accessories, see page 599.
3. For dimensions, see page 601.
5. For nameplates and shrouds, see page 600.
4. For contact assembly part numbers, see page 600.
7. All HW series E-stops comply with EN60947-5-5, the IEC “E-Stop Addendum to the Low
Voltage Directive,” this includes “tamper proof” operation whereby a change of contact state
is not possible by “teasing” or “floating” the operator.
8. All assembled part numbers in catalog include standard fingersafe (HW-F...) contacts.
9. Assembled units with spring-up terminals (HW-G...) can be ordered by removing an “F” from
the part number (Ex. HW1B-M1F11-R becomes HW1B-M111-R).
10. Units with exposed screw terminals (HW-C...) must be ordered as sub-components.
11. Operator only models include operator and button.
12. Additional contact configurations available (up to 6 total contacts).
www.IDEC.com
Switches & Pilot Devices
ø22mm - HW Series
H
W
1
B
–
V
3
F
10 – R – EMO-2
Engraved Button*
Bezel
EMO-2: EMO switch
1: Plastic Bezel
4: Metal Bezel
Function
V: Pushlock Turn Reset
X: Pushlock Key Reset
(not available for 60mm
jumbo mushroom)
*Option available for red
EMO E-Stop only
Operator
Button Colors
Contact Arrangement
Terminals
F: Fingersafe
C: Exposed Screw
blank: Springup
10: 1NO
01: 1NC
11: 1NO-NC
R: Red
Y: Yellow
20: 2NO
02: 2NC
22: 2NO-2NC
Note: some switches only
available in red.
Signaling Lights
3: ø29mm Head
4: ø40mm Head
5: ø60mm Head
Non-Illuminated E-Stop Pushbuttons (Replacement Parts)
Contact Blocks
+
Mounting Adaptor
+
Style
+
Standard
Fingersafe
(IP20)
HW-F10
HW-F01
HW-F10R
(early make)
HW-F01R
(late break)
HW-G10
HW-G01
HW-G10R
(early make)
HW-G01R
(late break)
HW-C10
HW-C01
HW-C10R
(early make)
HW-C01R
(late break)
Dummy
Block
Style
=
Completed Unit
Anti-Rotation Ring
Part Number
Appearance
HW9Z-LS
Part Number
HW9Z-RL
Use with notched panel cutout to prevent unit
rotation.
Operators
Style
Plastic
ø29mm Head Pushlock Turn Reset
ø40mm Head Pushlock Turn Reset
TW-DB
Metal
red
HW1B-V3R
HW4B-V3R
yellow
HW1B-V3Y
HW4B-V3Y
red
HW1B-V4R
HW4B-V4R
yellow
HW1B-V4Y
HW4B-V4Y
Contactors
1NC
Operator
Timers
1NO
Exposed
Screw
Terminal
Anti-Rotation
Ring
Safety Lever Lock
Contacts
Spring-Up
Terminal
+
Relays & Sockets
Contact Blocks
Safety Lever
Lock
Switches & Pilot Devices
Part Number Structure
ø40mm Head EMO Pushlock Turn Reset*
Contact Block Mounting Adaptor
Part Number
HW1B-V4R-EMO-2
HW4B-V4R-EMO-2
HW1B-X4R
HW4B-X4R
HW1B-V5R
–
Terminal Blocks
Style
ø40mm Head Pushlock Key Reset*
HW-CB2C
ø60mm Head Pushlock Turn Reset*
Circuit Breakers
1. Used to mount contact blocks to operator.
2. IDEC strongly recommends using the
safety lever lock to prevent heavy
vibration or maintenance personnel from
inadvertently unlocking contacts.
1. *Available in red only.
2. All E-Stop buttons are not removable from the operator.
800-262-IDEC (4332) • USA & Canada
559
Switches & Pilot Devices
Switches & Pilot Devices
ø22mm - HW Series
Relays & Sockets
Signaling Lights
Push Pull & Unibody E-Stop Pushbuttons (Assembled)
ø40mm Unibody Pushlock Turn Reset*
ø40mm Head Push–Pull
Timers
Contacts
Plastic Bezel
Metal Bezel
Contacts
Plastic Bezel
HW1E-BV4F11-R
Operator Only (Red)
HW1B-Y2R
HW4B-Y2R
1NO-1NC
Operator Only (Yellow)
HW1B-Y2Y
HW4B-Y2Y
2NC
HW1E-BV4F02-R
1NO
HW1B-Y2F10-j†
HW4B-Y2F10-j†
1NC
HW1B-Y2F01-j†
HW4B-Y2F01-j†
1NO-2NC
HW1E-BV412R-TK2093-1
1NO-1NC
HW1B-Y2F11-j†
HW4B-Y2F11-j†
2NC
HW1B-Y2F02-j†
HW4B-Y2F02-j†
2NO
HW1B-Y2F20-j†
HW4B-Y2F20-j†
l Full Voltage Code
Unibody Illuminated E-Stops*
Contactors
Contacts
LED
Incandescent
1NO-1NC
HW1E-LV4F11QD-R-l
HW1E-LV4F11Q-R-l
2NC
HW1E-LV4F02QD-R-l
HW1E-LV4F02Q-R-l
2NC (with push-on
illumination)
HW1E-TV4F02QD-R-l
HW1E-TV4F11Q-R-l
1NO-1NC (with push-on
illumination )
HW1E-TV4F11QD-R-l
HW1E-TV4F02Q-R-l
Terminal Numbering
(Unibody only)
Voltage
Code
6VAC/DC
6V
Models
Terminal Number
12VAC/DC
12V
1NO-1NC
NO = 13/14, NC = 11/12
24VAC/DC
24V
2NC
NC = 11/12, NC = 21/22
120V AC*
120V
Lamp + = X2, Lamp - = X1
240V AC*
240V
HW1E-L
HW1E-T
*LED only.
Circuit Breakers
Terminal Blocks
1. * Available in Red only.
2. † Available in red or yellow. Insert color code in place of j (R: Red, Y: Yellow).
3. In place of l, specify Full Voltage Code.
4. With single unit construction, the positive action contacts are integrated in the body of the switch. This provides an extra degree of safety and reliability for critical emergency stop functions.
5. In the illuminated version, the light is independent of the switch action (except push-on LED model).
6. For accessories, see page 599.
7. For dimensions, see page 601.
8. For nameplates and shrouds, see page 599.
9. For contact assembly part numbers, see page 599.
10. All HW Series E-Stop operators include non-removable color caps.
11. All HW series E-Stops comply with EN60947-5-5, the IEC “E-Stop Addendum to the Low Voltage Directive,” this includes “tamper proof” operation whereby a change of contact state is not possible by “teasing” or “floating” the operator.
12. All HW series E-Stop switches comply with SEMI S2 standards.
13. All assembled part numbers in catalog include standard fingersafe (HW-F...) contacts.
14. Assembled units with spring-up terminals (HW-G...) can be ordered by removing an “F” from the part number (Ex. HW1B-M1F11-R becomes HW1B-M111-R).
15. Units with exposed screw terminals (HW-C...) must be ordered as sub-components.
16. Additional contact configurations available (up to 6 total contacts).
560
www.IDEC.com
Switches & Pilot Devices
ø22mm - HW Series
H
W
1
E
–
LV4
F
11 – Q D R - 24V
Full Voltage Code
Button Colors (Illuminated E-Stop)
Bezel
1: Plastic Bezel
4: Metal Bezel*
(*not available for
HW1E unibody)
Function
Lamp Code
B: Push Pull
E: Pushlock Turn Reset
D: LED
blank: Incandescent
Illumination
Contacts
11: 1NO-1NC
02: 2NC
10: 1NO
20: 2NO
6V: 6V AC/DC
12V: 12V AC/DC
24V: 24V AC/DC
120V: 120VC AC*
240V: 240V AC*
(*only available in
40mm Push Pull
E-Stop)
Illumination Circuit
*LED only
Signaling Lights
BV4: Non-illuminated (unibody style)
LV4: Illuminated
TV4: Illuminated Push On
Y2: Non-illuminated Push Pull E-Stop
R: Red
Y: Yellow*
Switches & Pilot Devices
Part Number Structure
blank: 40mm Push Pull & Non-illuminated Unibody E-Stop
Q: Illuminated Unibody E-Stop
Illuminated & Non-Illuminated E-Stop Pushbuttons (Replacement Parts)
Mounting Adaptor
+
Contact Blocks
Style
Operator
Standard
Fingersafe
(IP20)
HW-F10
HW-F01
HW-F10R
(early make)
HW-F01R
(late break)
HW-G10
HW-G01
HW-G10R
(early make)
HW-G01R
(late break)
HW-C10
HW-C01
Style
Part Number
HW-C01R
(late break)
Completed Unit
Anti-Rotation Ring
Appearance
Part Number
HW9Z-RL
HW-CB2C
1. Used to mount contact blocks to operator.
2. IDEC strongly recommends using the
safety lever lock to prevent heavy vibration
or maintenance personnel from inadvertently unlocking contacts.
Safety Lever Lock
HW-C10R
(early make)
=
Style
Use with notched panel cutout to
prevent unit rotation.
Operators
Style
Part Number
ø40mm Head
Push-Pull
Plastic
HW1B-Y2R
Part Number
Metal
HW4B-Y2R
HW9Z-LS
Plastic
HW1B-Y2Y
TW-DB
HW4B-Y2Y
Terminal Blocks
Metal
1. There are no replacement parts for the HW1E unibody E-Stop.
2. For illuminated unibody E-Stop, see page 600 for replacement lens.
Contactors
1NC
Dummy
Block
+
Timers
1NO
Exposed
Screw
Terminal
Anti-Rotation
Ring
Contact Block Mounting Adaptor
Contacts
Spring-Up
Terminal
+
Relays & Sockets
Safety Lever
Lock
red
+
yellow
Contact Blocks
All E- Stop Buttons are not removable from the
operator.
Circuit Breakers
800-262-IDEC (4332) • USA & Canada
561
Switches & Pilot Devices
Switches & Pilot Devices
ø22mm - HW Series
Relays & Sockets
Signaling Lights
E-Stop Stations
29mm Pushlock Turn Reset
40mm Pushlock Turn Reset
Plastic Bezel
Metal Bezel
Plastic Bezel
Metal Bezel
1NO-1NC
FB1W-HW1B-V311R
FB1W-HW4B-V311R
FB1W-HW1B-V411R
FB1W-HW4B-V411R
2NC
FB1W-HW1B-V302R
FB1W-HW4B-V302R
FB1W-HW1B-V402R
FB1W-HW4B-V402R
Contacts
Plastic Bezel
Metal Bezel
Plastic Bezel
Metal Bezel
1NO-1NC
FB1W-HW1B-Y211R
FB1W-HW4B-Y211R
FB1W-HW1B-X411R
FB1W-HW4B-X411R
2NC
FB1W-HW1B-Y202R
FB1W-HW4B-Y202R
FB1W-HW1B-X402R
FB1W-HW4B-X402R
Timers
Contacts
Terminal Blocks
Contactors
40mm Push-Pull Reset
40mm Pushlock Key Reset
40mm EMO Pushlock Turn Reset
Contacts
Plastic Bezel
Metal Bezel
1NO-1NC
FB1W-HW1B-V411R-EMO-2
FB1W-HW4B-V411R-EMO-2
2NC
FB1W-HW1B-V402R-EMO-2
FB1W-HW4B-V402R-EMO-2
Circuit Breakers
1. Maximum of two contact blocks.
2. Box is supplied with yellow top and black bottom only.
562
www.IDEC.com
Switches & Pilot Devices
ø22mm - HW Series
Switches & Pilot Devices
Jumbo Dome Pilot Lights (Assembled)
Plastic Bezel
HW1P-5Q0
Full Voltage
24V AC/DC
HW1P-5Q4-k
Operator Only
HW1P-5Q7*
Full Voltage
24V AC/DC
HW1P-5Q7-k
Actual Size
Signaling Lights
Operator Only
Jumbo Dome
LED
Incandescent
Relays & Sockets
1. In place of k, specify the Lens/LED Color Code.
2. *Incandescent operator comes with bulb.
3. Available with spring-up terminals in 24V only.
4. For nameplates and accessories, see page 596 and 599.
5. For dimensions, see page 601.
k Lens/LED Color Code
Code
Amber
A
Green
G
Red
R
Blue
S
White
W
Yellow
Y
Timers
Color
Item
Appearance
Description
Contactors
Jumbo Dome Replacement Parts
Part Number
Lens
HW1A-P5k
Polycarbonate Lens
LED Diffusing
Lens*
HW9Z-PP5C
Terminal Blocks
LED Lamps
Jumbo Dome
LED Lamp
LSTDB-2k
1. In place of k, specify the Lens/LED Color Code.
2. *Diffusing lens for LED models only.
3. Use white LED for yellow lens.
Lamp Ratings
LED
LSTDB-2
Incandescent
LSB-2
Operating
Voltage
24V AC/DC ±10%
Rated
Current
Power
Consumption
15mA
0.36W
150mA
3.6W
800-262-IDEC (4332) • USA & Canada
Circuit Breakers
Part
Number
563
Switches & Pilot Devices
Switches & Pilot Devices
ø22mm - HW Series
Relays & Sockets
Signaling Lights
Pilot Lights (Assembled)
Round Flush
Dome
Plastic Bezel
Metal Bezel
Plastic Bezel
Metal Bezel
Operator Only
HW1P-1FQ0-k
HW4P-1FQ0-k
HW1P-2FQ0-k
HW4P-2FQ0-k
Full Voltage
HW1P-1FQm-k-l
HW4P-1FQm-k-l
HW1P-2FQm-k-l
HW4P-2FQm-k-l
120V AC
HW1P-1FH2m-k
HW4P-1FH2m-k
HW1P-2FH2m-k
HW4P-2FH2m-k
240V AC
HW1P-1FM4m-k
HW4P-1FM4m-k
HW1P-2FM4m-k
HW4P-2FM4m-k
480V AC
HW1P-1FT8m-k
HW4P-1FT8m-k
HW1P-2FT8m-k
HW4P-2FT8m-k
110V DC
HW1P-1D2D-k
–
HW1P-2D2D-k
–
Transformer
Timers
DC-DC Converter*
Square Flush
Contactors
Plastic Bezel
Operator Only
HW2P-1FQ0-k
Full Voltage
HW2P-1FQm-k-l
Transformer
DC-DC Converter*
120V AC
HW2P-1FH2m-k
240V AC
HW2P-1FM4m-k
480V AC
HW2P-1FT8m-k
110V DC
HW2P-1D2D-k
l Full Voltage Code
m Lamp Type Code
Color
Code
Voltage
Code
Lamp
Code
Amber
A
6VAC/DC
6V
Incandescent
Blank
Green
G
12VAC/DC
12V
LED
D
Red
R
24VAC/DC
24V
Blue
S
120V AC (LED only)
120V
White
W
240V AC (LED only)
240V
Yellow
Y
Circuit Breakers
Terminal Blocks
k Lens/LED Color Code
564
www.IDEC.com
1. In place of k, specify the Lens/LED Color Code from table below.
2. In place of lspecify the Full Voltage Code from table below.
3. In place of m specify Lamp Type Code from table below.
4. *DC-DC convertor voltage input from 90-140V DC, comes with
spring-up terminals only.
5. DC-DC converter models with LED lamps only.
6. For nameplates and accessories, see page 596 and 599.
7. For dimensions, see page 601.
8. Pilot lights do not come with anti-rotation ring.
9. Operator models come with operator and lens.
10. Yellow pilot light comes with white LED.
Switches & Pilot Devices
ø22mm - HW Series
Switches & Pilot Devices
Part Number Structure
H
W
1
P
–
2
F
Q
D – R – 12V
Lamp Voltage
Bezel
1: Round Plastic
2: Square Plastic
4: Round Metal
Operator
1: Flush
2: Dome
Illumination Circuit
Lens/LED Colors
Q: Full Voltage
H2: 120V AC Transformer
M4: 240V AC Transformer
T8: 480V AC Transformer
D2: DC-DC Converter
A: Amber
G: Green
R: Red
S: Blue
W: White
Y: Yellow
Lamp Type Code
D: LED
Blank: Incandescent
Signaling Lights
(full voltage units only)
6V: 6V AC/DC
12V: 12V AC/DC
24V: 24V AC/DC
120V: 120V AC*
240V: 240V AC*
*LED only
Pilot Lights (Replacement Parts)
Transformer*
+
Lamp
+
Operator
+
Lens
=
Completed Unit
Relays & Sockets
(not applicable for full voltage units)
Transformer Units
Style
LED/Incandescent
Voltage
Part Number
120V AC
HW-FH20
HW-MH20*
240V AC
HW-FM40
HW-MM40*
480V AC
HW-FT80
HW-RT80*
110V DC**
Style
Type
Plastic Bezel
Metal Bezel
Round Flush
Standard
HW1P-1FQ0
HW4P-1FQ0
Full Voltage
Transformer
Dome
Full Voltage
HW-RD0*
1. *With spring-up terminals - to use spring-up terminal
type, must use transformer type operator designed for
spring-up transformer.
2. ** DC-DC converter voltage input from 90-140V DC.
Transformer
Square Flush
Full Voltage
Lamps
Voltage
LED
Incandescent
Part Number
6V AC/DC
LSTD-6k
12V AC/DC
LSTD-1k
24V AC/DC
LSTD-2k
120V AC
LSTD-H2k
240V AC
LSTD-M4k
6V AC/DC
IS-6
IS-12
24V AC/DC
IS-24
1. In place of k, specify the LED Color Code.
2. The LED contains a current-limiting resistor
and reverse polarity protection diodes.
Spring-up Terminals
HW1P-100
–
Standard
HW1P-2FQ0
HW4P-2FQ0
Spring-up Terminals
HW1P-2Q0
HW4P-2Q0
Standard
HW1P-20
HW4P-20
Spring-up Terminals
HW1P-200
–
Standard
HW2P-1FQ0
–
Spring-up Terminals
HW2P-1Q0
Standard
HW2P-10
–
Spring-up Terminals
HW2P-100
–
Lenses
Style
l Lens Color Code
Part Number
Round/
Flush
Dome
HW1A-P1-l
HW1A-P2-l
Color
Code
Amber
A
Green
G
Red
R
Blue
S
White
W
Yellow
Y
For yellow lens use white LED.
Code
Color
Code
Amber
A
Blue
S
Green
G
White
W
Square/
Flush
HW2A-P1-l
Circuit Breakers
Color
R
HW4P-10
1. Transformer type requires separate transformer & lamp. Must select correct transformer bases on standard or
spring up terminal type. Use 6V lamps or LEDs.
2. Full voltage type only requires lamp.
k LED Color Code
Red
HW4P-1Q0
HW1P-10
Terminal Blocks
12V AC/DC
Transformer
HW1P-1Q0
Standard
Contactors
Style
Spring-up Terminals
Timers
(6V secondary
voltage)
Operators
In place of l, specify the Lens Color Code.
For yellow lens use white LED.
800-262-IDEC (4332) • USA & Canada
565
Switches & Pilot Devices
Illuminated Round Pushbuttons (Assembled)
Illuminated Full Voltage Pushbuttons
Flush
Extended
Extended w/ Full Shroud
Plastic Bezel
Metal Bezel
Plastic Bezel
Metal Bezel
Plastic Bezel
Metal Bezel
Momentary
Contacts
Operator Only
1NO
1NC
1NO-1NC
2NO
HW1L-M1-k
HW1L-M1F10Qm-k-l
HW1L-M1F01Qm-k-l
HW1L-M1F11Qm-k-l
HW1L-M1F20Qm-k-l
HW4L-M1-k
HW4L-M1F10Qm-k-l
HW4L-M1F01Qm-k-l
HW4L-M1F11Qm-k-l
HW4L-M1F20Qm-k-l
HW1L-M2-k
HW1L-M2F10Qm-k-l
HW1L-M2F01Qm-k-l
HW1L-M2F11Qm-k-l
HW1L-M2F20Qm-k-l
HW4L-M2-k
HW4L-M2F10Qm-k-l
HW4L-M2F01Qm-k-l
HW4L-M2F11Qm-k-l
HW4L-M2F20Qm-k-l
HW1L-MF2-k
HW1L-MF2F10Qm-k-l
HW1L-MF2F01Qm-k-l
HW1L-MF2F11Qm-k-l
HW1L-MF2F20Qm-k-l
HW4L-MF2-k
HW4L-MF2F10Qm-k-l
HW4L-MF2F01Qm-k-l
HW4L-MF2F11Qm-k-l
HW4L-MF2F20Qm-k-l
Maintained
Timers
Relays & Sockets
Signaling Lights
Switches & Pilot Devices
ø22mm - HW Series
Operator Only
1NO
1NC
1NO-1NC
2NO
HW1L-A1-k
HW1L-A1F10Qm-k-l
HW1L-A1F01Qm-k-l
HW1L-A1F11Qm-k-l
HW1L-A1F20Qm-k-l
HW4L-A1-k
HW4L-A1F10Qm-k-l
HW4L-A1F01Qm-k-l
HW4L-A1F11Qm-k-l
HW4L-A1F20Qm-k-l
HW1L-A2-k
HW1L-A2F10Qm-k-l
HW1L-A2F01Qm-k-l
HW1L-A2F11Qm-k-l
HW1L-A2F20Qm-k-l
HW4L-A2-k
HW4L-A2F10Qm-k-l
HW4L-A2F01Qm-k-l
HW4L-A2F11Qm-k-l
HW4L-A2F20Qm-k-l
HW1L-AF2-k
HW1L-AF2F10Qm-k-l
HW1L-AF2F01Qm-k-l
HW1L-AF2F11Qm-k-l
HW1L-AF2F20Qm-k-l
HW4L-AF2-k
HW4L-AF2F10Qm-k-l
HW4L-AF2F01Qm-k-l
HW4L-AF2F11Qm-k-l
HW4L-AF2F20Qm-k-l
Extended
Extended w/ Full Shroud
Metal Bezel
Plastic Bezel
Metal Bezel
Momentary
Flush
Plastic Bezel
Operator Only
1NO-1NC
2NO
HW1L-M1-k
HW1L-M1F11lm-k
HW1L-M1F20lm-k
HW4L-M1-k
HW4L-M1F11lm-k
HW4L-M1F20lm-k
HW1L-M2-k
HW1L-M2F11lm-k
HW1L-M2F20lm-k
HW4L-M2-k
HW4L-M2F11lm-k
HW4L-M2F20lm-k
HW1L-MF2-k
HW4L-MF2-k
HW1L-MF2F11lm-k HW4L-MF2F11lm-k
HW1L-MF2F20lm-k HW4L-MF2F20lm-k
Maintained
Contacts
Operator Only
1NO-1NC
2NO
HW1L-A1-k
HW1L-A1F11lm-k
HW1L-A1F20lm-k
HW4L-A1-k
HW4L-A1F11lm-k
HW4L-A1F20lm-k
HW1L-A2-k
HW1L-A2F11lm-k
HW1L-A2F20lm-k
HW4L-A2-k
HW4L-A2F11lm-k
HW4L-A2F20lm-k
HW1L-AF2-k
HW1L-AF2F11lm-k
HW1L-AF2F20lm-k
Terminal Blocks
Contactors
Illuminated Transformer Pushbuttons
1. In place of k, specify Lens/LED Color Code from
table.
2. In place of lspecify Voltage Code from table.
Circuit Breakers
3. In place of m specify Lamp Code from table.
4. Light independent of switch position.
5. For replacement part numbers, see page 567.
6. For nameplates and accessories, see page 596.
and 599.
7. For dimensions, see page 601.
8. For contact assembly part numbers, see page 600.
9. Full voltage and transformer models use the same
operator.
10. Additional contact configurations available (up to 6
total contacts).
11. Yellow pushbutton comes with white LED.
566
k Lens/LED Color Code
Color
Code
Amber
A
Green
G
Red
R
Blue
S
White
W
Yellow
l Voltage Code
Y
Transformer
Models
Voltage
Code
Voltage
Code
6V AC/DC
6V
120V AC
H2
12V AC/DC
12V
240V AC
M4
24V AC/DC
24V
480V AC
T8
120V AC (LED only)
120V
240V AC (LED only)
240V
www.IDEC.com
Metal Bezel
HW4L-AF2-k
HW4L-AF2F11lm-k
HW4L-AF2F20lm-k
m Lamp Code
Full Voltage
Models
Yellow LED not available. Use
white LED for yellow lens.
Plastic Bezel
Lamp
Code
Incandescent
Blank
LED
D
Switches & Pilot Devices
W
1
Switches & Pilot Devices
H
ø22mm - HW Series
Part Number Structure
– M F2 F 10 Q D – G – 12V
L
Lamp Voltage
Bezel
1: Plastic
4: Metal
Function
M: Momentary
A: Maintained
Lens Color
Operator
1F: Flush
2F: Extended
F2: Extended
w/ shroud
A: Amber S: Blue
G: Green W: White
R: Red
Y: Yellow
Contact Arrangement
Illumination Circuit
Q: Full Voltage
H2: Transformer 120V AC
M4: Transformer 240V AC
T8: Transformer 480V AC
Lamp Code
*LED only
D: LED
Blank: Incandescent
Signaling Lights
10: 1NO
01: 1NC
11: 1NO-1NC
20: 2NO
(full voltage units only)
6V: 6V AC/DC
12V: 12V AC/DC
24V: 24V AC/DC
120V: 120VC AC*
240V: 240V AC*
Illuminated Round Pushbuttons (Replacement Parts)
Transformer*
+
Contact
Blocks
+
Lead
Holder
+
Mounting
Adaptor
+
Safety
Lever Lock
+
Lamp
+
Anti-Rotation
Ring
+
Operator
+
Lens
Completed
Unit
=
Relays & Sockets
*Transformer not needed with full voltage models.
Lamp Circuit Components
Contact Blocks
Style
Description
Lead Holder
For use with HW-CBL on all
illuminated pushbutton units.
One required for each deck
(pair) of contacts.
Full Voltage Adaptor
Exposed
HW-DA1B
Spring Up
HW-GA1
Fingersafe
TW-DA1FB
Exposed
TW-DA1B
120VAC
240VAC
480VAC
Fingersafe
TW-F126B
TW-F246B
TW-F486B
120V
240V
480V
Spring Up
HW-T126
HW-T246
HW-L486
Exposed
TW-T126B
TW-T246B
TW-T486B
For use with
even number of
contacts.
110VDC
Operators
Metal
Bezel
Momentary
HW1L-M0
HW4L-M0
Round Flush/
Extended
Maintained
HW1L-A0
HW4L-A0
Momentary
HW1L-MF0
HW4L-MF0
Extended with
Full Shroud
Maintained
HW1L-AF0
HW4L-AF0
1NC
HW-F01
HW-F01R (late break)
Spring-Up
Terminal
HW-G10
HW-G10R (early make)
HW-G01
HW-G01R (late break)
Exposed Screw
Terminal
HW-C10
HW-C10R (early make)
HW-C01
HW-C01R (late break)
Contact Block Mounting Adaptor
Style
Part Number
Anti-Rotation Ring
Part
Number
Appearance
HW-CBL
1. Used to mount contact blocks to operator
(first pair only).
2. IDEC strongly recommends using the safety
lever lock to prevent heavy vibration or
maintenance personnel from inadvertently
unlocking contacts.
Safety Lever Lock
Style
HW9Z-RL
Use with notched panel cutout to prevent
unit rotation.
Lamps
Style
Part Number
HW9Z-LS
LED
Lenses
Style
Round Flush
Part Number
HW1A-L1-k
Round Extended
HW1A-L2-k
In place of k, specify the Lens
Color Code from previous page.
800-262-IDEC (4332) • USA & Canada
Incandescent
Voltage
Part Number
6V AC/DC
LSTD-6k
12V AC/DC
LSTD-1k
24V AC/DC
LSTD-2k
120V AC
LSTD-H2k
240V AC
LSTD-M4k
6V AC/DC
IS-6
12V AC/DC
IS-12
24V AC/DC
IS-24
1. In place of k, specify the LED Color Code.
2. The LED contains a current-limiting resistor
and reverse polarity protection diodes.
3. Yellow LED not available, use white LED
when using yellow lens.
567
Circuit Breakers
Plastic
Bezel
Style
1NO
HW-F10
HW-F10R (early make)
1. All assembled part numbers in catalog include standard fingersafe (HW-F...) contacts.
2. Assembled units with spring-up terminals (HW-G...) can be ordered by removing an “F” from
the part number (Ex. HW1B-M1F11-R becomes HW1B-M111-R).
3. Units with exposed screw terminals (HW-C...) must be ordered as sub-components.
HW-L16D
HW-GA1 “Dummy Block with full voltage adaptor” does not require the
use of HW-LH3.
Contacts
Standard
Fingersafe (IP20)
Terminal Blocks
HW-DA1FB
120V
240V
480V
DC-DC Converter
HW-LH3
Fingersafe
For use with
odd number of
contacts.
Style
Contactors
Transformer Unit
(6V secondary
voltage)
Part
Number
Timers
Dummy Block with
Full Voltage Adaptor
Terminals
Switches & Pilot Devices
Switches & Pilot Devices
ø22mm - HW Series
Relays & Sockets
Signaling Lights
Illuminated Mushroom & Square Pushbuttons (Assembled)
Full Voltage
Timers
Momentary
Transformer
Contactors
Momentary
Maintained
Plastic Bezel
Metal Bezel
Plastic Bezel
Operator Only†
HW1L-M4-k
HW4L-M4-k
HW2L-M1-k
1NO
HW1L-M4F10Qm-k-l
HW4L-M4F10Qm-k-l
HW2L-M1F10Qm-k-l
1NC
HW1L-M4F01Qm-k-l
HW4L-M4F01Qm-k-l
HW2L-M1F01Qm-k-l
1NO-1NC
HW1L-M4F11Qm-k-l
HW4L-M4F11Qm-k-l
HW2L-M1F11Qm-k-l
2NO
HW1L-M4F20Qm-k-l
HW4L-M4F20Qm-k-l
HW2L-M1F20Qm-k-l
Operator Only
HW1L-A4-k
HW4L-A4-k
HW2L-A1-k
1NO
HW1L-A4F10Qm-k-l
HW4L-A4F10Qm-k-l
HW2L-A1F10Qm-k-l
1NC
HW1L-A4F01Qm-k-l
HW4L-A4F01Qm-k-l
HW2L-A1F01Qm-k-l
1NO-1NC
HW1L-A4F11Qm-k-l
HW4L-A4F11Qm-k-l
HW2L-A1F11Qm-k-l
2NO
HW1L-A4F20Qm-k-l
HW4L-A4F20Qm-k-l
HW2L-A1F20Qm-k-l
1NO-1NC
HW1L-M4F11lm-k
HW4L-M4F11lm-k
HW2L-M1F11lm-k
2NO
HW1L-M4F20lm-k
HW4L-M4F20lm-k
HW2L-M1F20lm-k
1NO-1NC
HW1L-A4F11lm-k
HW4L-A4F11lm-k
HW2L-A1F11lm-k
2NO
HW1L-A4F20lm-k
HW4L-A4F20lm-k
HW2L-A1F20lm-k
1. † Full voltage and transformer units use the same
operator.
Terminal Blocks
2. In place of k, specify the Lens/LED Color Code
from table.
3. In place of lspecify the Voltage Code from
table.
Circuit Breakers
4. In place of m specify Lamp Type Code from
table.
5. Light independent of switch position
6. For nameplates and accessories, see page 596.
and 599.
7. For dimensions, see page 601.
8. For contact assembly part numbers, see page
600.
9. Additional contact configurations available (up to
6 total contacts).
10. Yellow pushbutton comes with white LED.
568
Square Flush
Contacts
†
Maintained
40mm Mushroom Head
k Lens/LED Color Code
Color
Code
Amber
A
Green
G
Red
R
Blue
S
White
W
Yellow
Y*
l Voltage Code
m Lamp Code
Full Voltage
Models
1. *40mm mushroom lenses
not available in yellow.
2. Yellow LED not available.
Use white LED for yellow
lens.
Transformer
Models
Voltage
Code
Voltage
Code
6V AC/DC
6V
120V AC
H2
12V AC/DC
12V
240V AC
M4
24V AC/DC
24V
480V AC
T8
120V AC (LED only)
120V
240V AC (LED only)
240V
www.IDEC.com
Lamp
Code
Incandescent
Blank
LED
D
Switches & Pilot Devices
W
1
Switches & Pilot Devices
H
ø22mm - HW Series
Part Number Structure
– M
1
F 10 Q D – G – 12V
L
Lamp Voltage
Bezel
1: Round Plastic
2: Square Plastic
4: Round Metal
Function
M: Momentary
A: Maintained
Lens Color
Operator
1: Square Flush
4: Mushroom
A: Amber S: Blue
G: Green W: White
R: Red
Y: Yellow
Contact Arrangement
Illumination Circuit
Q: Full Voltage
H2: Transformer 120V AC
M4: Transformer 240V AC
T8: Transformer 480V AC
Lamp Code
*LED only
D: LED
Blank: Incandescent
Signaling Lights
10: 1NO
01: 1NC
11: 1NO-1NC
20: 2NO
(full voltage units only)
6V: 6V AC/DC
12V: 12V AC/DC
24V: 24V AC/DC
120V: 120VC AC*
240V: 240V AC*
Illuminated Mushroom & Square Pushbuttons (Replacement Parts)
Transformer*
+
Contact
Blocks
+
Lead
Holder
+
Adaptor†
+
Safety
Lever Lock
+
Lamp
Anti-Rotation
Ring
+
+
Operator
+
Lens
Completed
Unit
=
Relays & Sockets
*Transformer not needed with full voltage models.
Lamp Circuit Components
Contact Blocks
Style
Description
Lead Holder
For use with HW-CBL on all
illuminated pushbutton units.
One required for each deck
(pair) of contacts.
Full Voltage Adaptor
For use with
even number of
contacts.
120VAC
240VAC
480VAC
120V
240V
480V
DC-DC Converter
HW-LH3
Fingersafe
HW-DA1FB
Exposed
HW-DA1B
Spring Up
HW-GA1
Fingersafe
TW-DA1FB
Exposed
TW-DA1B
Fingersafe
TW-F126B
TW-F246B
TW-F486B
Spring Up
HW-T126
HW-T246
HW-L486
Exposed
TW-T126B
TW-T246B
TW-T486B
Standard
Fingersafe (IP20)
HW-F10
HW-F10R (early make)
HW-F01
HW-F01R (late break)
Spring-Up
Terminal
HW-G10
HW-G10R (early make)
HW-G01
HW-G01R (late break)
Exposed Screw
Terminal
HW-C10
HW-C10R (early make)
HW-C01
HW-C01R (late break)
Contact Block Mounting Adaptor
Part Number
Appearance
1. Used to mount contact blocks to
operator (first pair only).
2. IDEC strongly recommends using the
safety lever lock to prevent heavy
vibration or maintenance personnel
from inadvertently unlocking contacts.
Safety Lever Lock
Style
Part Number
HW9Z-RL
Use with notched panel cutout
to prevent unit rotation.
Lamps
Style
LED
Momentary
HW1L-M0L
HW4L-M0L
Maintained
HW1L-A0L
HW4L-A0L
Momentary
HW2L-M0
Maintained
HW2L-A0
–
Style
Part Number
Incandescent
ø40mm
Mushroom
Lens
ALW4BLU-k*
Square
Flush
HW2A-L1-k
1. In place of k, specify the Lens Color Code.
2. *Mushroom lens not available in yellow.
800-262-IDEC (4332) • USA & Canada
Voltage
Part Number
6V AC/DC
LSTD-6k
12V AC/DC
LSTD-1k
24V AC/DC
LSTD-2k
120V AC
LSTD-H2k
240V AC
LSTD-M4k
6V AC/DC
IS-6
12V AC/DC
IS-12
24V AC/DC
IS-24
Circuit Breakers
Metal
Bezel
Part Number
HW-CBL
Lenses
Plastic
Bezel
Style
Anti-Rotation Ring
HW9Z-LS
Operators
Square
1NC
HW-L16D
HW-GA1 “Dummy Block with full voltage adaptor” does not
require the use of HW-LH3.
ø40mm
Mushroom
1NO
1. All assembled part numbers in catalog include standard fingersafe (HW-F...) contacts.
2. Assembled units with spring-up terminals (HW-G...) can be ordered by removing an
“F” from the part number (Ex. HW1B-M1F11-R becomes HW1B-M111-R).
3. Units with exposed screw terminals (HW-C...) must be ordered as sub-components.
Style
110VDC
Contacts
Terminal Blocks
120V
240V
480V
Style
Contactors
Transformer Unit
(6V secondary
voltage)
For use with
odd number of
contacts.
Part Number
Timers
Dummy Block with
Full Voltage Adaptor
Terminals
1. In place of k, specify the LED Color Code.
2. The LED contains a current-limiting resistor
and reverse polarity protection diodes.
3. Yellow LED not available, use white LED
when using yellow lens.
569
Switches & Pilot Devices
Switches & Pilot Devices
ø22mm - HW Series
Signaling Lights
Selector Switches 2-Position (Assembled)
Mounting
Contact
Operator
Position
L
Handle
R
Operator Only
Maintained
L
Spring Return
from Right
L
R
R
Knob
Lever
HWnS-2T
HWnS-2L
HWnS-21T
HWnS-21L
1NO
1
O
X
Knob
Lever
HWnS-2TF10
HWnS-2LF10
HWnS-21TF10
HWnS-21LF10
1NO1NC
1
2
O
X
X
O
Knob
Lever
HWnS-2TF11
HWnS-2LF11
HWnS-21TF11
HWnS-21LF11
2NO
1
2
O
O
X
X
Knob
Lever
HWnS-2TF20
HWnS-2LF20
HWnS-21TF20
HWnS-21LF20
2NO2NC
1
2
3
4
X
O
X
O
O
X
O
X
Knob
Lever
HWnS-2TF22
HWnS-2LF22
HWnS-21TF22
HWnS-21LF22
1. In place of n enter 1 for plastic bezel or 4 for metal bezel.
2. For nameplates, see page 596.
3. All assembled part numbers in catalog include standard fingersafe
(HW-F...) contacts.
4. Assembled units with spring-up terminals (HW-G...) can be
ordered by removing an “F” from the part number (Ex. HW1BM1F11-R becomes HW1B-M111-R).
5. Units with exposed screw terminals (HW-C...) must be ordered as
sub-components.
6. Standard color for knob and lever is black.
7. Optional colors available for lever type. Must order in components. See next page for part numbers.
8. Additional contact configurations available (up to 6 total contacts).
9. For Truth Tables see page 608.
n Bezel Type
Type
Code
Plastic
1
Metal
4
Circuit Breakers
Terminal Blocks
Contactors
Timers
Relays & Sockets
2-Position Selector Switches
570
www.IDEC.com
Switches & Pilot Devices
ø22mm - HW Series
Switches & Pilot Devices
Part Number Structure
H
W
1
S
-
2
1
T
F
10
Contact Arrangement
10: 1NO
11: 1NO-1NC
20: 2NO
Bezel
1: Plastic
4: Metal
# of Positions
2: 2-Position
Handle
Operator
T: Knob
L: Lever
Signaling Lights
blank: Maintained
1: Spring Return
from Right
Selector Switches 2-Position (Replacement Parts)
Contact Blocks
+
Mounting Adaptor
+
Safety Lever Lock
Style
1NC
Standard
Fingersafe
(IP20)
HW-F10
HW-F01
HW-F10R
(early make)
HW-F01R
(late break)
HW-G10
HW-G01
HW-G10R
(early make)
HW-G01R
(late break)
HW-C10
HW-C01
Exposed
Screw
Terminal
=
Completed Unit
Style
Part Number
HW9Z-RL
Use with notched panel cutout to prevent
unit rotation.
Operators
Style
Description
Handle
Plastic Bezel
Metal Bezel
Knob
HW1S-2T
HW4S-2T
Lever
HW1S-2
HW4S-2
Knob
HW1S-21T
HW4S-21T
Lever
HW1S-21
HW4S-21
Maintained
HW-C01R
(late break)
TW-DB
Spring Return
from Right
Contact Block Mounting Adaptor
Part Number
Contactors
HW-C10R
(early make)
Dummy
Block
1. Knob operator comes with black handle.
2. To order lever type, lever and inserts must be ordered separately, along with lever
operator. See part numbers below.
Levers & Inserts
Style
Part Number
1. Used to mount contact blocks to operator (first pair only).
2. IDEC strongly recommends using the safety lever lock to
prevent heavy vibration or maintenance personnel from
inadvertently unlocking contacts.
Lever
Safety Lever Lock
TW-HC1-j
Standard lever color is black. Standard
insert color is white.
800-262-IDEC (4332) • USA & Canada
j Handle/Insert
Color Code
Color
Code
Black*
B
Blue
S
Green
G
Red
R
Yellow
Y
White
W
†
Circuit Breakers
Lever
Color
Insert
Part Number
ASWHHL-j
Terminal Blocks
HW-CB2C
HW9Z-LS
Operator
Timers
1NO
Spring-Up
Terminal
Style
+
Anti-Rotation Ring
Contacts
Style
Anti-Rotation
Ring
Relays & Sockets
Contact Blocks
+
1. * Lever color inserts not available in black.
2. †Lever not available in white.
571
Switches & Pilot Devices
Selector Switches 3-Position (Assembled)
Mounting
3–Position Selector Switches
Operator Position
L
C
Handle
R
Operator Only
Spring Return
from Right
Maintained
L
C
L
R
C
Spring Return
from Left
L
R
C
Spring Return
Two-Way
L
R
C
Knob
Lever
HWnS-3T*
HWnS-3L
HWnS-31T
HWnS-31L
HWnS-32T
HWnS-32L
HWnS-33T
HWnS-33L
R
1NO1NC
1
2
0
0
X
0
X
X
Knob
Lever
HWnS-3TF11
HWnS-3LF11
HWnS-31TF11
HWnS-31LF11
HWnS-32TF11
HWnS-32LF11
HWnS-33TF11
HWnS-33LF11
2NO
1
2
X
0
0
0
0
X
Knob
Lever
HWnS-3TF20
HWnS-3LF20
HWnS-31TF20
HWnS-31LF20
HWnS-32TF20
HWnS-32LF20
HWnS-33TF20
HWnS-33LF20
2NC
1
2
0
X
X
X
X
0
Knob
Lever
HWnS-3TF02
HWnS-3LF02
HWnS-31TF02
HWnS-31LF02
HWnS-32TF02
HWnS-32LF02
HWnS-33TF02
HWnS-33LF02
2NO1NC
1
2
3
X
0
0
0
0
X
0
X
0
Knob
HWnS-3JTF21N1
–
–
–
2NO2NC
1
2
3
4
X
0
0
X
0
0
X
X
0
X
X
0
Knob
HWnS-3TF22
HWnS-31TF22
HWnS-32TF22
HWnS-33TF22
2NO2NC
1
2
3
4
0
X
X
0
0
0
X
0
X
0
0
X
Knob
HWnS-3STF22N9
–
–
–
4NO
1
2
3
4
X
0
X
0
0
0
0
0
0
X
0
X
Knob
4NO
1
2
3
4
X
0
X
0
0
X
0
0
0
X
0
X
Knob
HWnS-3STF40N2
–
–
–
4NC
1
2
3
4
0
X
0
X
X
X
X
X
X
0
X
0
Knob
HWnS-3TF04
HWnS-31TF04
HWnS-32TF04
HWnS-33TF04
n Bezel Type
HWnS-3TF40
HWnS-31TF40
1. In place of n enter 1 for plastic bezel or 4 for metal bezel.
2. Knob operator includes black knob/lever operator includes black lever.
3. * Three position operator is available with three different cams.
HWnS-3T: Maintained (standard cam)
HWnS-3ST: Maintained (S cam)
HWnS-3JT: Maintained (J cam)
4. Operator cams are color coded (white=standard cam, red=S cam, black =J cam).
5. For nameplates, see page 596.
6. For contact assembly part numbers, see page 600
Circuit Breakers
Terminal Blocks
Contactors
Timers
Relays & Sockets
Contact
Signaling Lights
Switches & Pilot Devices
ø22mm - HW Series
572
HWnS-32TF40
HWnS-33TF40
Type
Code
Plastic
1
Metal
4
7. All assembled part numbers in catalog include standard fingersafe (HW-F...) contacts.
8. Assembled units with spring-up terminals (HW-G...) can be ordered by removing an “F”
from the part number (Ex. HW1B-M1F11-R becomes HW1B-M111-R).
9 . Units with exposed screw terminals (HW-C...) must be ordered as sub-components.
10. Standard color for knob and lever is black.
11. Optional colors available for lever type. Must order in components. See next page for
part numbers.
12. Additional contact configurations available (up to 6 total contacts).
13. For Truth Tables see page 608.
www.IDEC.com
Switches & Pilot Devices
ø22mm - HW Series
Switches & Pilot Devices
Part Number Structure
H
W
1
S
-
3
1
T
F
20
Contact Arrangement
11: 1NO-1NC
20: 2NO
21: 2NO-1NC
22: 2NO-2NC
40: 4NO
04: 4NC
Bezel
1: Plastic
4: Metal
# of Positions
3: 3-Position
Handle
Operator
T: Knob
L: Lever
Signaling Lights
blank: Maintained
1: Spring Return from Right
2: Spring Return from Left
3: Spring Return Two Way
Selector Switches 3-Position (Replacement Parts)
Contact Blocks
+
Mounting Adaptor
+
Safety Lever Lock
Style
Anti-Rotation
Ring
=
Completed Unit
1NC
Standard
Fingersafe
(IP20)
HW-F10
HW-F01
HW-F10R
(early make)
HW-F01R
(late break)
HW-G10
HW-G01
HW-G10R
(early make)
HW-G01R
(late break)
HW-C10
HW-C01
HW-C10R
(early make)
HW-C01R
(late break)
Exposed
Screw
Terminal
Dummy
Block
Style
Part Number
Use with notched panel cutout to
prevent unit rotation.
Operators
Style
TW-DB
Description
Handle
Plastic Bezel
Metal Bezel
Maintained
(standard cam)
Knob
HW1S-3T
HW4S-3T
Lever
HW1S-3
HW4S-3
Maintained (S cam)
Knob
HW1S-3ST
HW4S-3ST
Maintained (J cam)
Knob
HW1S-3JT
HW4S-3JT
Spring Return from
Right (standard cam)
Knob
HW1S-31T
HW4S-31T
Lever
HW1S-31
HW4S-31
Knob
HW1S-32T
HW4S-32T
Lever
HW1S-32
HW4S-32
Knob
HW1S-33T
HW4S-33T
Lever
HW1S-33
HW4S-33
Spring Return from
Left (standard cam)
Part Number
2-Way Spring Return
(standard cam)
HW-CB2C
Contactors
Contact Block Mounting Adaptor
1. Knob operator comes with black handle.
2. Three position knob operator is available with three different cams.
3. Operator cams are color coded (white=standard cam, red=S cam, black =J cam).
4. To order lever type, lever and inserts must be ordered separately, along with lever operator.
See part numbers below.
Levers & Inserts
Style
j Handle/Insert Color Code
Part Number
Safety Lever Lock
Lever
Part Number
Lever
Color
Insert
ASWHHL-j
TW-HC1-j
Color
Code
Color
Code
Black*
B
Red
R
Blue
S
Yellow
Y
Green
G
White†
W
Circuit Breakers
HW9Z-LS
Terminal Blocks
1. Used to mount contact blocks to operator (first pair only).
2. IDEC strongly recommends using the safety lever lock to
prevent heavy vibration or maintenance personnel from inadvertently unlocking contacts.
HW9Z-RL
Timers
1NO
Spring-Up
Terminal
Style
Operator
Anti-Rotation Ring
Contacts
Style
+
Relays & Sockets
Contact Blocks
+
1. * Lever color inserts not
available in black.
2. †Lever not available in white.
Standard lever color is black. Standard
insert color is white.
800-262-IDEC (4332) • USA & Canada
573
Switches & Pilot Devices
Switches & Pilot Devices
ø22mm - HW Series
Signaling Lights
Selector Switches 4- & 5-Position (Assembled)
2
3
4
Maintained
1
2
3
4
Knob
Lever
HWnS-4T
HWnS-4L
Operator Only
2NO2NC
1NO2NC
1
2
3
4
X
0
0
0
0
X
0
0
O
0
X
0
O
0
0
0
Knob
Lever
HWnS-4TF12
HWnS-4LF12
1NO3NC
1
2
3
4
O
O
O
O
X
X
O
O
X
O
X
O
X
O
O
X
Knob
Lever
HWnS-4TF13N6
HWnS-4LF13N6
2NO2NC
1
2
3
4
X
O
O
O
O
X
O
O
O
O
X
O
O
O
O
X
Knob
Lever
HWnS-4TF22N3
HWnS-4LF22N3
1. In place of n enter 1 for plastic bezel or 4 for metal bezel.
2. Knob operator includes black knob/lever operator includes black lever.
3. For nameplates, see page 596.
4. For contact assembly part numbers, see page 600.
5. Five position circuit cannot be made to make five independent contact closures.
6. All assembled part numbers in catalog include standard fingersafe (HW-F...) contacts.
7. Assembled units with spring-up terminals (HW-G...) can be ordered by removing an “F”
from the part number (Ex. HW1B-M1F11-R becomes HW1B-M111-R).
8. Units with exposed screw terminals (HW-C...) must be ordered as sub-components.
9. Standard color for knob and lever is black.
10. Optional colors available for lever type. Must order in components. See next page for
part numbers.
11. Additional contact configurations available (up to 6 total contacts).
12. For Truth Tables see page 608.
1
2
3
4
n Bezel Type
Type
Code
Plastic
1
Metal
4
Circuit Breakers
Terminal Blocks
Mounting
1
Handle
Contact
Mounting
Contact
5-Position Selector Switch
Operator Position
Operator Only
Contactors
Timers
Relays & Sockets
4-Position Selector Switches
574
www.IDEC.com
Operator Position
1
X
O
O
O
2
O
X
O
O
3
O
O
O
O
4
O
O
X
O
Handle
5
O
O
O
X
Maintained
2
3
1
4
5
Knob
Lever
HWnS-5T
HWnS-5L
Knob
Lever
HWnS-5TF22N3
HWnS-5LF22N3
Switches & Pilot Devices
ø22mm - HW Series
Switches & Pilot Devices
Part Number Structure
H
W
1
S
-
4
T
F
13N6
Contact Arrangement
Bezel
1: Plastic
4: Metal
(based on desired truth table)
12: 1NO-2NC
13N6: 1NO-3NC
22N3: 2NO-2NC
# of Positions
4: 4-Position
5: 5-Position
Handle
T: Knob
L: Lever
Signaling Lights
Selector Switches 4- & 5-Position (Replacement Parts)
Contact Blocks
+
Mounting Adaptor
+
Safety Lever Lock
Style
Anti-Rotation
Ring
+
1NC
Standard
Fingersafe
(IP20)
HW-F10
HW-F01
HW-F10R
(early make)
HW-F01R
(late break)
HW-G10
HW-G01
HW-G10R
(early make)
HW-G01R
(late break)
HW-C10
HW-C01
HW-C10R
(early make)
HW-C01R
(late break)
Exposed
Screw
Terminal
Style
Part Number
HW9Z-RL
Use with notched panel cutout to prevent
unit rotation.
Operators
Style
Position
4
TW-DB
5
Description
Handle
Plastic Bezel
Metal Bezel
Knob
HW1S-4T
HW4S-4T
Lever
HW1S-4
HW4S-4
Knob
HW1S-5T
HW4S-5T
Lever
HW1S-5
HW4S-5
Maintained
Contactors
Dummy
Block
Maintained
Contact Block Mounting Adaptor
1. Knob operator comes with black handle.
2. To order lever type, lever and inserts must be ordered separately, along with lever operator. See
part numbers below.
Part Number
Levers & Inserts
HW-CB2C
Part Number
Lever
Lever
Color
Insert
Safety Lever Lock
TW-HC1-j
Standard lever color is black. Standard
insert color is white.
800-262-IDEC (4332) • USA & Canada
Color
Code
Black*
B
Blue
S
Green
G
Red
R
Yellow
Y
White
W
†
Circuit Breakers
Part Number
ASWHHL-j
j Handle/Insert
Color Code
Terminal Blocks
Style
1. Used to mount contact blocks to operator (first pair only).
2. IDEC strongly recommends using the safety lever lock to
prevent heavy vibration or maintenance personnel from
inadvertently unlocking contacts.
HW9Z-LS
Completed Unit
Timers
1NO
Spring-Up
Terminal
Style
=
Anti-Rotation Ring
Contacts
Style
Operator
Relays & Sockets
Contact Blocks
+
1. * Lever color inserts not
available in black.
2. †Lever not available in white.
575
Switches & Pilot Devices
Key Switches 2-Position (Assembled)
Contact
Mounting
2-Position Key Switches
Operator
Position
L
R
Operator Only
Maintained
L
R
Spring Return
from Right
L
R
HWnK-2A
HWnK-21B
1NO
1
O
X
HWnK-2AF10
HWnK-21BF10
1NO1NC
1
2
0
X
X
0
HWnK-2AF11
HWnK-21BF11
2NO
1
2
O
O
X
X
HWnK-2AF20
HWnK-21BF20
2NO2NC
1
2
3
4
0
X
0
X
X
0
X
0
HWnK-2AF22
HWnK-21BF22
Timers
Relays & Sockets
Signaling Lights
Switches & Pilot Devices
ø22mm - HW Series
Contactors
1. In place of n enter 1 for plastic bezel or 4 for metal bezel.
2. Key is removable in all maintained positions. Other key removable options available.
3. Two keys are supplied with all switches.
4. All standard operators are keyed alike.
5. Other key removable options available. See table below
6. For nameplates, see page 596.
7. For contact assembly part numbers, see page 600.
8. Key is retained in “Spring Return” position.
9. All assembled part numbers in catalog include standard fingersafe (HW-F...) contacts.
10. Assembled units with spring-up terminals (HW-G...) can be ordered by removing an “F” from the part
number (Ex. HW1B-M1F11-R becomes HW1B-M111-R).
11. Units with exposed screw terminals (HW-C...) must be ordered as sub-components.
12. Additional contact configurations available (up to 6 total contacts).
13. For Truth Tables see page 600.
Code
Description
A
Key not retained in any position (removable in all positions)
B
Key retained in right position only
C
Key retained in left position only
Circuit Breakers
Terminal Blocks
Key Removable Option Codes
576
www.IDEC.com
n Bezel Type
Type
Code
Plastic
1
Metal
4
Switches & Pilot Devices
ø22mm - HW Series
Switches & Pilot Devices
Part Number Structure
H
W
1
K
-
2
1
B
F
10
Contact Arrangement
10: 1NO
20: 2NO
11: 1NO-1NC 22: 2NO-2NC
Bezel
1: Plastic
4: Metal
# of Positions
2: 2-Position
Operator
Key Retained Position
blank: Maintained
1: Spring Return from Right
Signaling Lights
A: Key not retained in any position (removable in all positions)
B: Key retained in right position only
C: Key retained in left position only
Key Switches 2-Position (Replacement Parts)
Contact Assembly
+
Mounting Adaptor
+
Safety Lever Lock
Style
+
Operator
=
Completed Unit
Safety Lever Lock
1NC
Standard
Fingersafe
(IP20)
HW-F10
HW-F01
HW-F10R
(early make)
HW-F01R
(late break)
HW-G10
HW-G01
HW-G10R
(early make)
HW-G01R
(late break)
HW-C10
HW-C01
HW-C10R
(early make)
HW-C01R
(late break)
Exposed
Screw
Terminal
Dummy
Block
Style
HW9Z-LS
Anti-Rotation Ring
Style
Part Number
HW-CB2C
Use with notched panel cutout to prevent unit rotation.
Operators
Description
Plastic Bezel
Metal Bezel
Maintained
HW1K-2A
HW4K-2A
Maintained, key removed
left only
HW1K-2B
HW4K-2B
Spring Return from Right
HW1K-21B
HW4K-21B
Maintained, key removed
right only
HW1K-2C
HW4K-2C
Terminal Blocks
Contact Block Mounting Adaptor
Part Number
HW9Z-RL
Style
TW-DB
Part Number
Contactors
1NO
Timers
Contacts
Spring-Up
Terminal
Style
Anti-Rotation
Ring
Relays & Sockets
Contact Blocks
+
1. Operator includes two keys.
2. All standard operators are keyed alike.
Circuit Breakers
1. Used to mount contact blocks to operator
(first pair only).
2. IDEC strongly recommends using the
safety lever lock to prevent heavy
vibration or maintenance personnel from
inadvertently unlocking contacts.
800-262-IDEC (4332) • USA & Canada
577
Switches & Pilot Devices
Key Switches 3-Position (Assembled)
Mounting
3-Position Key Switches
Contact
Signaling Lights
Switches & Pilot Devices
ø22mm - HW Series
Operator Position
L
C
R
Spring Return
from Right
Maintained
L
C
L
R
C
R
Spring Return
from Left
L
C
Spring Return Two
Way
L
R
C
R
n Bezel Type
HWnK-3A*
HWnK-31B
HWnK-32C
HWnK-33D
Type
Code
HWnK-31BF11
HWnK-32CF11
HWnK-33DF11
Plastic
1
Metal
4
1NO1NC
1
2
0
0
X
0
X
X
HWnK-3AF11
2NO
1
2
X
0
0
0
0
X
HWnK-3AF20
HWnK-31BF20
HWnK-32CF20
HWnK-33DF20
2NC
1
2
0
X
X
X
X
0
HWnK-3AF02
HWnK-31BF02
HWnK-32CF02
HWnK-33DF02
2NO1NC
1
2
3
X
0
0
0
0
X
0
X
0
HWnK-3JAF21N1
2NO2NC
1
2
3
4
X
0
0
X
0
0
X
X
0
X
X
0
HWnK-3AF22
2NO2NC
1
2
3
4
0
X
X
0
0
0
X
0
X
0
0
X
HWnK-3SAF22N9
4NO
1
2
3
4
X
0
X
0
0
0
0
0
0
X
0
X
HWnK-3AF40
4NO
1
2
3
4
X
0
X
0
0
X
0
0
0
X
0
X
HWnK-3SAF40N2
4NC
1
2
3
4
0
X
0
X
X
X
X
X
X
0
X
0
HWnK-3AF04
Terminal Blocks
Contactors
Timers
Relays & Sockets
Operator Only
Circuit Breakers
1. In place of n enter 1 for plastic bezel or 4 for metal
bezel.
2. Key is removable in all maintained positions. Other
key removable options available.
3. Two keys are supplied with all switches.
4. All standard operators are keyed alike.
5. Other key removable options available. See table to
the right.
6. * Operator is available with three different cams.
HWnK-3A: Maintained (standard cam)
HWnK-3SA: Maintained (Cam S)
HWnK-3JA: Maintained (Cam J)
7. For nameplates, see page 596.
578
–
HWnK-31BF22
–
HWnK-31BF40
–
HWnK-31BF04
–
HWnK-32CF22
–
HWnK-33DF22
–
HWnK-32CF40
–
HWnK-33DF40
–
HWnK-32CF04
8. For contact assembly part numbers, see page 600.
9. All assembled part numbers in catalog include
standard fingersafe (HW-F...) contacts.
10. Assembled units with spring-up terminals (HW-G...)
can be ordered by removing an “F” from the part
number (Ex. HW1B-M1F11-R becomes HW1B-M111R).
11. Units with exposed screw terminals (HW-C...) must
be ordered as sub-components.
12. Additional contact configurations available (up to 6
total contacts).
13. For Truth Tables see page 608.
www.IDEC.com
–
HWnK-33DF04
Key Removable Option Codes
Code
Description
A
Key not retained in any position (removable in all positions)
B
Key retained in right position only
C
Key retained in left position only
D
Key retained in left and right (3 position only)
E
Key retained in center only (3 position only)
G
Key retained right and center (3 position only)
H
Key retained left and center (3 position only)
Switches & Pilot Devices
ø22mm - HW Series
Switches & Pilot Devices
Part Number Structure
H
W
1
K
-
3
1
B
F
11
Contact Arrangement
11: 1NO-1NC 40: 4NO
20: 2NO
04: 4NC
22: 2NO-2NC
Bezel
1: Plastic
4: Metal
# of Positions
3: 3-Position
Operator
blank: Maintained
1: Spring Return from Right
2: Spring Return from Left
3: Spring Return Two Way
Key Removable Option Code
(see chart on previous page)
Signaling Lights
Key Switches 3-Position (Replacement Parts)
Contact Assembly
+
Mounting Adaptor
+
Safety Lever Lock
Style
Standard
Fingersafe
(IP20)
HW-F10
HW-F01
HW-F10R
(early make)
HW-F01R
(late break)
HW-G10
HW-G01
HW-G10R
(early make)
HW-G01R
(late break)
HW-C10
HW-C01
HW-C10R
(early make)
HW-C01R
(late break)
Style
Completed Unit
Part Number
HW9Z-LS
Anti-Rotation Ring
Style
Part Number
HW9Z-RL
Style
TW-DB
1.
2.
3.
4.
Description
Plastic Bezel
Metal Bezel
Maintained (standard cam)
HW1K-3A
HW4K-3A
Maintained (S cam)
HW1K-3SA
HW4K-3SA
Maintained (J cam)
HW1K-3JA
HW4K-3JA
Spring Return from Right (standard cam)
HW1K-31B
HW4K-31B
Spring Return from Left (standard cam)
HW1K-32C
HW4K-32C
2-Way Spring Return (standard cam)
HW1K-33D
HW4K-33D
Terminal Blocks
Part Number
HW-CB2C
Use with notched panel cutout to prevent
unit rotation.
Operators
Contact Block Mounting Adaptor
Style
=
Contactors
1NC
Dummy
Block
Operator
Timers
1NO
Exposed
Screw
Terminal
+
Safety Lever Lock
Contacts
Spring-Up
Terminal
Anti-Rotation
Ring
Relays & Sockets
Contact Blocks
+
Operator includes two keys.
All standard operators are keyed alike.
Other key removable options available. See table on previous page.
Key not removable from spring-returned position
Circuit Breakers
1. Used to mount contact blocks to operator
(first pair only).
2. IDEC strongly recommends using the
safety lever lock to prevent heavy vibration
or maintenance personnel from inadvertently unlocking contacts.
800-262-IDEC (4332) • USA & Canada
579
Switches & Pilot Devices
Switches & Pilot Devices
ø22mm - HW Series
Signaling Lights
Illuminated Selector Switches 2-Position (Assembled)
2-Position Illuminated Selector Switches
Relays & Sockets
Contact
Mounting
Style
Operator
Position
L
Part Number
Type
R
L
Operator Only
Full Voltage
Timers
L
R
HWnF-2k
1NO1NC
1
2
O
X
X
O
2NO
1
2
O
O
X
X
2NO2NC
1
2
3
4
O
X
O
X
X
O
X
O
Transformer
Transformer
HWnF-21k
HWnF-2F11Qm-k-l
HWnF-21F11Qm-k-l
HWnF-2F11H2m-k
HWnF-2F11M4m-k
HWnF-2F11T8m-k
HWnF-21F11H2m-k
HWnF-21F11M4m-k
HWnF-21F11T8m-k
HWnF-2F20Qm-k-l
HWnF-21F20Qm-k-l
120V
240V
480V
HWnF-2F20H2m-k
HWnF-2F20M4m-k
HWnF-2F20T8m-k
HWnF-21F20H2m-k
HWnF-21F20M4m-k
HWnF-21F20T8m-k
HWnF-2F22Qm-k-l
HWnF-21F22Qm-k-l
120V
240V
480V
HWnF-2F22H2m-k
HWnF-2F22M4m-k
HWnF-2F22T8m-k
HWnF-21F22H2m-k
HWnF-21F22M4m-k
HWnF-21F22T8m-k
Full Voltage
Transformer
R
120V
240V
480V
Full Voltage
Contactors
1. In place of k specify Lens/LED color code.
2. In place of l specify Full Voltage code.
3. In place of m specify Lamp code.
4. In place of n enter 1 for plastic bezel or 4 for metal bezel.
5. For nameplates, see page 596.
6. For contact assembly part numbers, see page 600.
7. Light is independent of switch position.
8. All assembled part numbers in catalog include standard fingersafe (HW-F...) contacts.
9. Assembled units with spring-up terminals (HW-G...) can be ordered by removing an “F” from the part number (Ex.
HW1B-M1F11-R becomes HW1B-M111-R).
10. Units with exposed screw terminals (HW-C...) must be ordered as sub-components.
11. Yellow selector switch comes with white LED.
12. Additional contact configurations available (up to 6 total contacts).
13. For Truth Tables see page 608.
k Lens/LED Color Code
Circuit Breakers
Terminal Blocks
Spring Return from
Right
Maintained
580
l Full Voltage Code
n Bezel Code
Color
Code
Lamp
Code
Type
Code
Amber
A
Voltage
Code
Incandescent
Blank
Plastic
1
Green
G
6VAC/DC
6V
LED
D
Metal
4
Red
R
12VAC/DC
12V
Blue
S
24VAC/DC
24V
White
W
120V AC (LED only)
120V
Yellow
Y
240V AC (LED only)
240V
Full Voltage Models
m Lamp Code
www.IDEC.com
Switches & Pilot Devices
W
1
F
Part Number Structure
– 21 F 20 Q D – G – 24V
Bezel
1: Plastic
4: Metal
Lamp Voltage
Contact Arrangement
2: Maintained
21: Spring Return
from Right
11: 1NO-1NC
20: 2NO
22: 2NO-2NC
Illumination Circuit
Q: Full Voltage
H2: Transformer 120V AC
M4: Transformer 240V AC
T8: Tranformer 480V AC
Illuminated Selector Switches 2-Position (Replacement Parts)
Transformer*
+
Contact
Blocks
+
Lead
Holder
+
Mounting
Adaptor
+
Safety
Lever Lock
+
Lamp
+
Anti-Rotation
Ring
+
Operator
+
Lens
=
Completed Unit
Contact Blocks
Lamp Circuit Components
Style
Description
Lead Holder
For use with HW-CBL on all
illuminated pushbutton units.
One required for each deck
(pair) of contacts.
Dummy Block with
Full Voltage Adaptor
For use with
odd number of
contacts.
For use with
even number of
contacts.
120VAC
240VAC
480VAC
120V
240V
480V
DC-DC Converter
HW-LH3
Fingersafe
HW-DA1FB
Exposed
HW-DA1B
Spring Up
HW-GA1
Fingersafe
TW-DA1B
Fingersafe
TW-F126B
TW-F246B
TW-F486B
Spring Up
HW-T126
HW-T246
HW-L486
Exposed
TW-T126B
TW-T246B
TW-T486B
110VDC
Operators
Style
Description
Plastic
Bezel
Metal Bezel
Maintained
HW1F-2
HW4F-2
Spring return
from right
HW1F-21
HW4F-21
1NC
Standard
Fingersafe (IP20)
HW-F10
HW-F10R (early make)
HW-F01
HW-F01R (late break)
Spring-Up
Terminal
HW-G10
HW-G10R (early make)
HW-G01
HW-G01R (late break)
Exposed Screw
Terminal
HW-C10
HW-C10R (early make)
HW-C01
HW-C01R (late break)
Part Number
HW-CBL
1. Used to mount contact blocks to
operator (first pair only).
2. IDEC strongly recommends
using the safety lever lock to prevent
heavy vibration or maintenance
personnel from inadvertently unlocking contacts.
Safety Lever Lock
Style
Part Number
Color
Code
Color
Code
Amber
A
Blue
S
Green
G
White
W
Red
R
Yellow
Y
Anti-Rotation Ring
Style
Part Number
HW9Z-RL
Use with notched panel cutout to
prevent unit rotation.
Lamps
Style
HW9Z-LS
LED
Illuminated Knob
Appearance
Part Number
HW9Z-FDY-k
In place of k, specify the
Color Code.
Illuminated knobs must be ordered separately.
800-262-IDEC (4332) • USA & Canada
Incandescent
Voltage
Part Number
6V AC/DC
LSTD-6k
12V AC/DC
LSTD-1k
24V AC/DC
LSTD-2k
120V AC
LSTD-H2k
240V AC
LSTD-M4k
6V AC/DC
IS-6
12V AC/DC
IS-12
24V AC/DC
IS-24
Circuit Breakers
Style
HW-L16D
1. HW-GA1 “Dummy Block with full voltage adaptor” does not require the
use of HW-LH3.
2. DC-DC convertor features spring-up terminals.
3. DC-DC convertor applicable voltage range 90-140V DC.
1NO
Contact Block Mounting Adaptor k Lens/LED Color Code
TW-DA1FB
Exposed
Contacts
Terminal Blocks
120V
240V
480V
Style
Contactors
Transformer Unit
(6V secondary
voltage)
Terminals
Part
Number
Timers
Full Voltage Adaptor
Relays & Sockets
*Transformer not needed with full voltage models.
Signaling Lights
(Full voltage units only)
6V: 6V AC/DC
A: Amber S: Blue
G: Green W: White 12V: 12V AC/DC
R: Red
Y: Yellow 24V: 24V AC/DC
120V: 120V AC*
Lamp Code
240V: 240V AC*
D: LED
*LED only
Blank: Incandescent
Lens Color
Position
Switches & Pilot Devices
H
ø22mm - HW Series
1. In place of k, specify the LED Color Code.
2. The LED contains a current-limiting resistor and
reverse polarity protection diodes.
3. Use white LED for yellow lens. Yellow LED not
available.
581
Switches & Pilot Devices
Signaling Lights
Switches & Pilot Devices
ø22mm - HW Series
Illuminated Selector Switches 3-Position (Assembled)
3-Position Illuminated Selector Switches
Mounting
Contact
Relays & Sockets
Style
Part Number
Operator Position
L
C
Type
R
L
Operator Only
Full Voltage
1NO1NC
1
2
O
O
X
O
X
X
2NO
1
2
O
0
X
0
O
X
2NC
1
2
O
X
X
X
X
O
2NO2NC
1
2
3
4
X
O
O
X
O
O
X
X
O
X
X
O
X
O
X
O
O
O
O
O
O
X
O
X
Full Voltage
4NO
1
2
3
4
O
X
O
X
X
X
X
X
X
O
X
O
Full Voltage
4NC
1
2
3
4
Transformer
120V
240V
480V
120V
240V
480V
Full Voltage
Transformer
582
120V
240V
480V
Full Voltage
Transformer
Transformer
Transformer
1. In place of k specify Lens/LED color
code.
2. In place of l specify Full Voltage
code.
3. In place of m specify Lamp code.
4. In place of n enter 1 for plastic bezel
or 4 for metal bezel.
5. For nameplates, see page 596.
6. For contact assembly part numbers,
see page 600.
7. Light is independent of switch position.
8. All assembled part numbers in catalog
include standard fingersafe (HW-F...)
contacts.
Circuit Breakers
Terminal Blocks
Contactors
Timers
Full Voltage
Transformer
Spring Return from
Right
Maintained
120V
240V
480V
120V
240V
480V
120V
240V
480V
C
L
R
C
R
Spring Return from
Left
L
C
Spring Return TwoWay
L
R
C
R
HWnF-3k
HWnF-31k
HWnF-32k
HWnF-33k
HWnF-3F11Qm-k-l
HWnF-31F11Qm-k-l
HWnF-32F11Qm-k-l
HWnF-33F11Qm-k-l
HWnF-3F11H2m-k
HWnF-3F11M4m-k
HWnF-3F11T8m-k
HWnF-31F11H2m-k
HWnF-31F11M4m-k
HWnF-31F11T8m-k
HWnF-32F11H2m-k
HWnF-32F11M4m-k
HWnF-32F11T8m-k
HWnF-33F11H2m-k
HWnF-33F11M4m-k
HWnF-33F11T8m-k
HWnF-3F20Qm-k-l
HWnF-31F20Qm-k-l
HWnF-32F20Qm-k-l
HWnF-33F20Qm-k-l
HWnF-3F20H2m-k
HWnF-3F20M4m-k
HWnF-3F20T8m-k
HWnF-31F20H2m-k
HWnF-31F20M4m-k
HWnF-31F20T8m-k
HWnF-32F20H2m-k
HWnF-32F20M4m-k
HWnF-32F20T8m-k
HWnF-33F20H2m-k
HWnF-33F20M4m-k
HWnF-33F20T8m-k
HWnF-3F02Qm-k-l
HWnF-31F02Qm-k-l
HWnF-32F02Qm-k-l
HWnF-33F02Qm-k-l
HWnF-3F02H2m-k
HWnF-3F02M4m-k
HWnF-3F02T8m-k
HWnF-31F02H2m-k
HWnF-31F02M4m-k
HWnF-31F02T8m-k
HWnF-32F02H2m-k
HWnF-32F02M4m-k
HWnF-32F02T8m-k
HWnF-33F02H2m-k
HWnF-33F02M4m-k
HWnF-33F02T8m-k
HWnF-3F22Qm-k-l
HWnF-31F22Qm-k-l
HWnF-32F22Qm-k-l
HWnF-33F22Qm-k-l
HWnF-3F22H2m-k
HWnF-3F22M4m-k
HWnF-3F22T8m-k
HWnF-31F22H2m-k
HWnF-31F22M4m-k
HWnF-31F22T8m-k
HWnF-32F22H2m-k
HWnF-32F22M4m-k
HWnF-32F22T8m-k
HWnF-33F22H2m-k
HWnF-33F22M4m-k
HWnF-33F22T8m-k
HWnF-3F40Qm-k-l
HWnF-31F40Qm-k-l
HWnF-32F40Qm-k-l
HWnF-33F40Qm-k-l
HWnF-3F40H2m-k
HWnF-3F40M4m-k
HWnF-3F40T8m-k
HWnF-31F40H2m-k
HWnF-31F40M4m-k
HWnF-31F40T8m-k
HWnF-32F40H2m-k
HWnF-32F40M4m-k
HWnF-32F40T8m-k
HWnF-33F40H2m-k
HWnF-33F40M4m-k
HWnF-33F40T8m-k
HWnF-3F04Qm-k-l
HWnF-31F04Qm-k-l
HWnF-32F04Qm-k-l
HWnF-33F04Qm-k-l
HWnF-3F04H2m-k
HWnF-3F04M4m-k
HWnF-3F04T8m-k
HWnF-31F04H2m-k
HWnF-31F04M4m-k
HWnF-31F04T8m-k
HWnF-32F04H2m-k
HWnF-32F04M4m-k
HWnF-32F04T8m-k
HWnF-33F04H2m-k
HWnF-33F04M4m-k
HWnF-33F04T8m-k
9. Assembled units with spring-up
terminals (HW-G...) can be ordered
by removing an “F” from the part
number (Ex. HW1B-M1F11-R becomes
HW1B-M111-R).
10. Units with exposed screw terminals
(HW-C...) must be ordered as subcomponents.
11. Yellow selector switch comes
with white LED.
12. Additional contact configurations
available (up to 6 total contacts).
13. For Truth Tables see page 608.
k Lens/LED Color
l Full Voltage Code
Color
Code
Lamp
Code
Amber
A
Voltage
Code
Incandescent
Blank
Green
G
6VAC/DC
6V
LED
D
Red
R
12VAC/DC
12V
Blue
S
24VAC/DC
24V
White
W
120V AC (LED only)
120V
Yellow
Y
240V AC (LED only)
240V
www.IDEC.com
Full Voltage Models
m Lamp Code
n Bezel Code
Type
Code
Plastic
1
Metal
4
Switches & Pilot Devices
W
1
F
Part Number Structure
– 31 F 20 Q D – G – 24V
Bezel
Full Voltage Code
6V: 6V AC/DC
12V: 12V AC/DC
A: Amber S: Blue
G: Green W: White 24V: 24V AC/DC
R: Red
Y: Yellow 120V: 120V AC*
240V: 240V AC*
Lens Color
Contact Arrangement
11: 1NO-1NC 22: 2NO-2NC Illumination Circuit
20: 2NO
40: 4NO
Q: Full Voltage
02: 2NC
04: 4NC
H2: Transformer 120V AC
M4: Transformer 240V AC
T8: Tranformer 480V AC
Lamp Code
*LED only
D: LED
Blank: Incandescent
Illuminated Selector Switches 3-Position (Replacement Parts)
Transformer*
Contact
Blocks
+
+
Lead
Holder
+
Mounting
Adaptor
+
Safety
Lever Lock
+
Lamp
+
Anti-Rotation
Ring
+
Operator
+
Lens
=
Completed Unit
Lamp Circuit Components
Style
Description
Dummy Block with
Full Voltage Adaptor
Contacts
1NO
1NC
Standard
Fingersafe (IP20)
HW-F10
HW-F10R (early make)
HW-F01
HW-F01R (late break)
HW-LH3
Spring-Up
Terminal
HW-G10
HW-G10R (early make)
HW-G01
HW-G01R (late break)
Fingersafe
HW-DA1FB
Exposed
HW-DA1B
Exposed Screw
Terminal
HW-C10
HW-C10R (early make)
HW-C01
HW-C01R (late break)
Spring Up
HW-GA1
Terminals
Fingersafe
TW-DA1FB
Exposed
TW-DA1B
Fingersafe
TW-F126B
TW-F246B
TW-F486B
120V
240V
480V
Spring Up
HW-T126
HW-T246
HW-L486
120V
240V
480V
Exposed
TW-T126B
TW-T246B
TW-T486B
For use with
even number of
contacts.
120VAC
240VAC
480VAC
Part Number
HW-CBL
1. Used to mount contact blocks to operator (first pair only).
2. IDEC strongly recommends
using the safety lever lock to prevent
heavy vibration or maintenance
personnel from inadvertently unlocking
contacts.
Description
Plastic Bezel
Metal
Bezel
Maintained
HW1F-3
HW4F-3
HW1F-31
HW4F-31
HW1F-32
HW4F-32
2-Way spring return
HW1F-33
HW4F-33
Code
Color
Code
Amber
A
Blue
S
Green
G
White
W
Red
R
Yellow
Y
Anti-Rotation Ring
Style
Style
Part Number
Part Number
HW9Z-RL
Use with notched panel cutout to prevent
unit rotation.
Lamps
Style
HW9Z-LS
LED
Illuminated Knob
Part Number
HW9Z-FDY-k
In place of k, specify the Color Code.
Illuminated knobs must be ordered separately.
800-262-IDEC (4332) • USA & Canada
Incandescent
Voltage
Part Number
6V AC/DC
LSTD-6k
12V AC/DC
LSTD-1k
24V AC/DC
LSTD-2k
120V AC
LSTD-H2k
240V AC
LSTD-M4k
6V AC/DC
IS-6
12V AC/DC
IS-12
24V AC/DC
IS-24
1. In place of k, specify the LED Color Code.
2. The LED contains a current-limiting resistor and
reverse polarity protection diodes.
3. Use white LED for yellow lens. Yellow LED not
available.
583
Circuit Breakers
Spring return from right
Spring return from left
Color
Safety Lever Lock
Appearance
Operators
Style
HW-L16D
1. HW-GA1 “Dummy Block with full voltage adaptor” does not require the
use of HW-LH3.
2. DC-DC convertor features spring-up terminals.
3. DC-DC convertor applicable voltage range 90-140V DC.
Style
Contact Block Mounting Adaptor k Lens/LED Color Code
Terminal Blocks
110VDC
Style
Contactors
DC-DC Converter
For use with
odd number of
contacts.
Part
Number
Timers
Full Voltage Adaptor
Transformer Unit
(6V secondary
voltage)
Contact Blocks
For use with HW-CBL on all
illuminated pushbutton units.
One required for each deck
(pair) of contacts.
Lead Holder
Relays & Sockets
*Transformer not needed with full voltage models.
Signaling Lights
1: Plastic Position
4: Metal 3: Maintained
31: Spring Return
from Right
32: Spring Return
from Left
33: Spring Return 2-Way
Switches & Pilot Devices
H
ø22mm - HW Series
Switches & Pilot Devices
Switches & Pilot Devices
ø22mm - HW Series
Signaling Lights
Mono Lever Switches 2-Position (Assembled)
2-Position Mono Lever Switches
HW1M
Standard Lever
Timers
Relays & Sockets
Style
Contactors
HW1M-L
Interlocking Lever
Part Number
Description
HW1M-F1010-20
Maintained up and down
HW1M-F2020-20
Spring return up and down
HW1M-F1010-40
Maintained up and down
HW1M-F2020-40
Spring return up and down
HW1M-F0101-20
Maintained right and left
HW1M-F0202-20
Spring return right and left
HW1M-F0101-40
Maintained right and left
HW1M-F0202-40
Spring return right and left
HW1M-LF1010-20
Maintained up and down
HW1M-LF2020-20
Spring return up and down
HW1M-LF1010-40
Maintained up and down
HW1M-LF2020-40
Spring return up and down
HW1M-LF0101-20
Maintained right and left
HW1M-LF0202-20
Spring return right and left
HW1M-LF0101-40
Maintained right and left
HW1M-LF0202-40
Spring return right and left
Circuit Diagrams
2 Position Left/Right
Circuit
Number
20
40
Circuit
Number
20
40
Terminal Blocks
Circuit Breakers
No.
Position
Left
Center
Right
X
0
0
HW-F10
0
0
X
HW-F10
X
0
0
HW-F10
0
0
X
HW-F10
X
0
0
HW-F10
0
0
X
1
HW-F10
2
1
2
3
4
2 Position Up/Down
1. All assembled part numbers in catalog include standard (HW-F...) contacts.
2. Assembled units with spring-up terminals (HW-G...) can be ordered by removing an “F”
from the part number (Ex. HW1B-M1F11-R becomes HW1B-M111-R).
3. Units with exposed screw terminals (HW-C...) must be ordered as sub-components.
4. Additional contact configurations available (up to 6 total contacts).
584
Contact Mounting
www.IDEC.com
Contact Mounting
No.
Position
Down
Center
Up
X
0
0
HW-F10
0
0
X
HW-F10
X
0
0
HW-F10
0
0
X
HW-F10
X
0
0
HW-F10
0
0
X
1
HW-F10
2
1
2
3
4
Switches & Pilot Devices
ø22mm - HW Series
Switches & Pilot Devices
Part Number Structure
H
W
1
M
-
L F 0
blank: Standard
L: Interlocking
1
0
1
up right down left
Type
20
Circuit Number
20 or 40 (see contact arrangement on previous page)
Lever Action
1: Maintained
2: Spring
0: Blocked
Signaling Lights
Mono Lever Switches 2-Position (Sub-assembled) Part Numbers
Contact Assembly
+
Mounting Adaptor
+
Style
Anti-Rotation
Ring
+
Operator
=
Completed Unit
Anti-Rotation Ring
1NO
1NC
Standard
Fingersafe
(IP20)
HW-F10
HW-F01
HW-F10R
(early make)
HW-F01R
(late break)
HW-G10
HW-G01
HW-G10R
(early make)
HW-G01R
(late break)
Spring-Up
Terminal
Exposed
Screw
Terminal
HW-C10
HW-C01
HW-C10R
(early make)
HW-C01R
(late break)
Part Number
HW9Z-RL
Use with notched panel cutout to prevent
unit rotation.
Operators
Style
Description
Part Number
Standard
Maintained Up/Down
HW1M-1010
Spring return Up/Down
HW1M-2020
Maintained Left/Right
HW1M-0101
Spring return Left/Right
HW1M-0202
Maintained Up/Down
HW1M-L1010
Spring return Up/Down
HW1M-L2020
Maintained Left/Right
HW1M-L0101
Spring return Left/Right
HW1M-L0202
Interlocking
TW-DB
Contact Block Mounting Adaptor
Part Number
Contactors
Dummy
Block
Style
Timers
Contacts
Style
+
Relays & Sockets
Contact Blocks
Safety Lever
Lock
Replacement Parts
HW-CB2C
Part Number
Terminal Blocks
Item
Black Cap
HW9Z-CPM
1. Used to mount contact blocks to operator (first pair only).
2. IDEC strongly recommends using the safety
lever lock (included) to prevent heavy vibration
or maintenance personnel from inadvertently unlocking
contacts.
Style
HW9Z-BLM (fits standard
operator only)
Circuit Breakers
Safety Lever Lock
Boot
Part Number
HW9Z-LS
800-262-IDEC (4332) • USA & Canada
585
Switches & Pilot Devices
Switches & Pilot Devices
ø22mm - HW Series
Signaling Lights
Mono Lever Switches 3- & 4-Position (Assembled)
3-Position
4-Position
Relays & Sockets
Style
Part Number
Description
HW1M
Standard Lever
HW1M-F0121-30
Maintained right and left,
spring return down
Style
HW1M-F0222-30
Spring return right, down, left
HW1M-L
Interlocking Lever
HW1M-LF0121-30
Maintained right and left,
spring return down
HW1M-LF0222-30
Spring return right, down, left
HW1M
Standard Lever
Circuit Diagram
Timers
Circuit
Number
30
Contact Mounting
No.
Position
Down
Left
Center
Up
Right
1
HW-F01
0
0
0
O
X
2
HW-F01
X
0
0
O
0
3
HW-F10
0
X
0
0
0
HW1M-L
Interlocking Lever
Contactors
22N9
HW1M-F1212-22N9
Maintained up and down,
spring left and right
HW1M-2121-22N9
Spring up and down, maintained left and right
HW1M-2222-22N9
Spring return all positions
HW1M-LF1111-22N9
Maintained all positions
HW1M-LF1212-22N9
Maintained up and down,
spring left and right
HW1M-LF2121-22N9
Spring up and down, maintained left and right
HW1M-LF2222-22N9
Spring return all positions
No.
Position
Down
Left
Center
Up
Right
HW-F01
0
O
0
0
X
2
HW-F01
X
0
0
0
0
3
HW-F10
0
X
0
0
0
4
HW-F10
0
0
0
X
0
Terminal Blocks
All assembled part numbers in catalog include standard (HW-F...) contacts.
Assembled units with spring-up terminals (HW-G...) can be ordered by removing an “F” from the part number (Ex. HW1B-M1F11-R becomes HW1B-M111-R).
Units with exposed screw terminals (HW-C...) must be ordered as sub-components.
Additional contact configurations available (up to 6 total contacts).
Circuit Breakers
Maintained all positions
Contact Mounting
1
586
Description
HW1M-F1111-22N9
Circuit Diagram
Circuit
Number
1.
2.
3.
4.
Part Number
www.IDEC.com
Switches & Pilot Devices
ø22mm - HW Series
Switches & Pilot Devices
Part Number Structure
H
W
1
M
-
L F 0
blank: Standard
L: Interlocking
1
2
1
up right down left
Type
30
Circuit Number
3 Position: 30
4 Position: 22N9
Lever Action
1: Maintained
2: Spring
0: Blocked
Signaling Lights
Mono Lever Switches 3 & 4-Position (Sub-assembled) Part Numbers
Contact Assembly
+
Mounting Adaptor
+
Style
Anti-Rotation
Ring
+
1NO
1NC
Standard
Fingersafe
(IP20)
HW-F10
HW-F01
HW-F10R
(early make)
HW-F01R
(late break)
HW-G10
HW-G01
HW-G10R
(early make)
HW-G01R
(late break)
Style
HW-C01
Standard
=
Completed Unit
Exposed
Screw
Terminal
HW-C10
HW-C10R
(early make)
Part Number
HW9Z-RL
Use with notched panel cutout to prevent unit rotation.
Operators
HW-C01R
(late break)
TW-DB
Interlocking
Contact Block Mounting Adaptor
Part Number
HW1M-0121
Spring return, 3 position
HW1M-0222
Maintained, 4 position
HW1M-1111
Combination, 4 position
HW1M-1212
Combination, 4 position
HW1M-2121
Spring return, 4 position
HW1M-2222
Combination, 3 position
HW1M-L0121
Spring return, 3 position
HW1M-L0222
Maintained, 4 position
HW1M-L1111
Combination, 4 position
HW1M-L1212
Combination, 4 position
HW1M-L2121
Spring return, 4 position
HW1M-L2222
Replacement Parts
Item
1. Used to mount contact blocks to operator (first pair only).
2. IDEC strongly recommends using the safety lever lock (included) to prevent heavy vibration or maintenance personnel
from inadvertently unlocking contacts.
Part Number
Black Cap
HW9Z-CPM
Boot
Part Number
Circuit Breakers
Safety Lever Lock
Part Number
Combination, 3 position
Terminal Blocks
HW-CB2C
Description
Contactors
Dummy
Block
Style
Timers
Spring-Up
Terminal
Style
Operator
Anti-Rotation Ring
Contacts
Style
+
Relays & Sockets
Contact Blocks
Safety
Lever Lock
HW9Z-BLM (fits standard
operator only)
HW9Z-LS
800-262-IDEC (4332) • USA & Canada
587
Switches & Pilot Devices
Signaling Lights
Switches & Pilot Devices
ø22mm - HW Series
Pushbutton Selectors (Assembled)
2-Position Pushbutton Selectors
Operator Position
Left
Relays & Sockets
Cam
Contacts
Mounting
Normal
j Button Color Code
Right
Push
Normal
Push
Operator Only
1NO-1NC
A
HW1R-2A-j
1
2
HW-F10
HW-F01
0
X
X
0
0
0
X
0
1
2
HW-F10
HW-F10
0
0
X
X
0
X
X
X
HW1R-2AF20-j
2NO-2NC
1
2
3
4
HW-F10
HW-F01
HW-F10
HW-F01
0
X
0
X
X
0
X
0
0
0
0
0
X
0
X
0
HW1R-2AF22-j
2NO
1
2
HW-F10
HW-F10
0
0
X
0
0
0
0
X
HW1R-2DF20-j
2NO-2NC
1
2
3
4
HW-F10
HW-F10
HW-F01
HW-F01
0
0
X
X
X
0
0
X
0
0
X
X
0
X
X
0
HW1R-2DF22N1-j
1
2
3
4
HW-F10
HW-F10
HW-F01
HW-F01
0
0
0
X
X
0
0
X
0
0
X
0
0
X
X
0
1
2
3
4
HW-F10
HW-F10
HW-F01
HW-F01
0
0
0
X
0
X
0
0
0
0
X
0
X
0
0
0
1
2
3
4
HW-F01
HW-F10
HW-F01
HW-F10
0
0
0
0
0
X
0
X
X
0
X
0
0
X
0
X
Timers
D
HW1R-2D-j
Operator Only
Contactors
2NO-2NC
HW1R-2E-j
Operator Only
F
2NO-2NC
Terminal Blocks
2NO-2NC
Circuit Breakers
2NO-2NC
HW1R-2NF22N2-j
HW1R-2T-j
1
2
3
4
HW-F10
HW-F10
HW-F01
HW-F01
0
0
X
X
1. All assembled part numbers in catalog include standard
(HW-F...) contacts.
2. Assembled units with spring-up terminals (HW-G...) can
be ordered by removing an “F” from the part number (Ex.
HW1B-M1F11-R becomes HW1B-M111-R).
588
HW1R-2FF22N1-j
HW1R-2N-j
Operator Only
T
HW1R-2EF22N1-j
HW1R-2F-j
Operator Only
N
HW1R-2AF11-j
2NO
Operator Only
E
Part Number
X
X
0
0
X
X
0
0
Blocked
HW1R-2TF22N1-j
3. Units with exposed screw terminals (HW-C...) must be
ordered as sub-components.
4. Operator only models come with operator and button.
5. Additional contact configurations available (up to 6 total
contacts).
www.IDEC.com
Color
Code
Color
Code
Black
B
White
W
Green
G
Yellow
Y
Red
R
Gray
N
Blue
S
Switches & Pilot Devices
ø22mm - HW Series
Switches & Pilot Devices
Part Number Structure
H
W
1
R
-
2
D
F
22N1 – R
Button Colors
Operator
B: Black
G: Green
R: Red
S: Blue
W: White
Y: Yellow
N: Gray
Contact Arrangement Code
11: 1NO-1NC
20: 2NO
(For additional contact codes see
previous page)
Signaling Lights
A: Cam A
D: Cam D
E: Cam E
F: Cam F
N: Cam N
T: Cam T
Pushbutton Selectors (Sub-assembled)
Contact Blocks
+
Mounting Adaptor
+
Safety Lever
Lock
Style
Anti-Rotation
Ring
+
Operator
Safety Lever Lock
Contacts
Standard
Fingersafe
(IP20)
Exposed
Screw
Terminal
1NC
HW-F01
HW-F10R
(early make)
HW-F01R
(late break)
HW-G10
HW-G01
HW-G10R
(early make)
HW-G01R
(late break)
HW-C10
HW-C01
HW-C10R
(early make)
HW-C01R
(late break)
TW-DB
Contact Block Mounting Adaptor
(safety lever lock included)
Style
Part Number
Part Number
Part Number
Round Flush
HW9Z-LS
HW1A-B1-j
Anti-Rotation Ring
Style
HW9Z-RL
Style
Part Number
Use with notched panel cutout to prevent
unit rotation.
Description
Part
Number
Cam A
HW1R-2A
Cam D
HW1R-2D
Cam E
HW1R-2E
Cam F
HW1R-2F
Cam N
HW1R-2N
Cam T
HW1R-2T
In place of j, specify the
Button Color Code from table
below.
j Button Color Code
Color
Code
Color
Black
B
White
Code
W
Green
G
Yellow
Y
Red
R
Gray
N
Blue
S
Terminal Blocks
Style
Completed Unit
Buttons
Operators
Dummy
Block
=
Contactors
HW-F10
Style
Button
Timers
Spring-Up
Terminal
1NO
+
Relays & Sockets
Contact Blocks
+
HW-CB2C
800-262-IDEC (4332) • USA & Canada
Circuit Breakers
1. Used to mount contact blocks to operator (first pair only).
2. IDEC strongly recommends using the safety
lever lock (included) to prevent heavy vibration
or maintenance personnel from inadvertently unlocking
contacts.
589
Switches & Pilot Devices
Dual Pushbutton Switches
Key features:
• Two pushbuttons and a pilot light are integrated into one spacesaving ø22 mm control unit.
• Momentary and interlock types are available for pushbuttons. Interlock type prevents both buttons from being pressed at the same time.
• Pilot lights are available in full voltage and transformer with LED or
incandescent lamps.
• IP40 protection, IP65 when using silicon cover.
• UL Listed, CSA approved, and EN compliant
Applications:
• Ideal for use as power switches and start/stop switches (available
with I/ON and O/OFF markings on the buttons and a pilot light in the
center).
• Interlock type prevents two pushbuttons from being pressed at the
same time.
Relays & Sockets
Signaling Lights
Switches & Pilot Devices
ø22mm - HW Series
Dual Pushbutton Switches (Assembled) Part Numbers
Without Center Pilot Light
Timers
Operation
Type
Button Style
Flush (top)
Flush (bottom)
Momentary
Contactors
Flush (top)
Extended (bottom)
Interlock*
Flush (top)
Extended (bottom)
Top Button
Bottom Button
1NO
1NC
Part Number
590
mButton Color
Code
nLegend Code
HW7D-B11F1001-mn
1NO
1NO
HW7D-B11F1010-mn
1NO-1NC
1NO-1NC
HW7D-B11F1111-mn
2NO
2NC
HW7D-B11F2002-mn
2NO
2NO
HW7D-B11F2020-mn
1NO
1NC
HW7D-B12F1001-mn
1NO
1NO
HW7D-B12F1010-mn
1NO-1NC
1NO-1NC
HW7D-B12F1111-mn
2NO
2NC
HW7D-B12F2002-mn
2NO
2NO
HW7D-B12F2020-mn
1NO
1NC
HW7D-B21F1001-mn
1NO
1NO
HW7D-B21F1010-mn
1NO-1NC
1NO-1NC
HW7D-B21F1111-mn
2NO
2NC
HW7D-B21F2002-mn
2NO
2NO
HW7D-B21F2020-mn
HW7D-B22F1001-mn
1NO
1NC
1NO
1NO
HW7D-B22F1010-mn
1NO-1NC
1NO-1NC
HW7D-B22F1111-mn
2NO
2NC
HW7D-B22F2002-mn
2NO
2NO
HW7D-B22F2020-mn
1. *Interlock type prevents both top and bottom buttons from being pressed simultaneously.
2. Clear silicon rubber cover part number HW9Z-D7D.
3. Additional contact configurations available (up to 6 total contacts).
Circuit Breakers
Terminal Blocks
Flush (top)
Flush (bottom)
Contact Arrangement
www.IDEC.com
GR:
Green (top)
Red (bottom)
WB:
White (top)
Black (bottom)
Blank:
Without legend
1:
I/ON (top)
O/OFF (bottom)
Switches & Pilot Devices
ø22mm - HW Series
Switches & Pilot Devices
With Center Pilot Light
Operation
Type
Button Style
Flush (Top)
Flush (Bottom)
Flush (top)
Flush (bottom)
Momentary
Flush (top)
Extended (bottom)
Interlock*
Flush (Top)
Extended (Bottom)
Part Number
1NO
1NC
HW7D-L11F1001kl-mn
1NO
1NO
HW7D-L11F1010kl-mn
1NO-1NC
1NO-1NC
HW7D-L11F1111kl-mn
2NO
2NC
HW7D-L11F2002kl-mn
2NO
2NO
HW7D-L11F2020kl-mn
1NO
1NC
HW7D-L12F1001kl-mn
1NO
1NO
HW7D-L12F1010kl-mn
1NO-1NC
1NO-1NC
HW7D-L12F1111kl-mn
2NO
2NC
HW7D-L12F2002kl-mn
2NO
2NO
HW7D-L12F2020kl-mn
1NO
1NC
HW7D-L21F1001kl-mn
1NO
1NO
HW7D-L21F1010kl-mn
1NO-1NC
1NO-1NC
HW7D-L21F1111kl-mn
2NO
2NC
HW7D-L21F2002kl-mn
2NO
2NO
HW7D-L21F2020kl-mn
1NO
1NC
HW7D-L22F1001kl-mn
1NO
1NO
HW7D-L22F1010kl-mn
1NO-1NC
1NO-1NC
HW7D-L22F1111kl-mn
2NO
2NC
HW7D-L22F2002kl-mn
2NO
2NO
HW7D-L22F2020kl-mn
Relays & Sockets
Flush (Top)
Flush (Bottom)
Bottom Button
Signaling Lights
Flush (Top)
Extended (Bottom)
Top Button
kPilot Light Illumination
& Voltage Code
Full Voltage
l Pilot Lamp Color Code
Timers
1. *Interlock type prevents both top and bottom buttons from being pressed simultaneously.
2. Clear silicon rubber cover part number HW9Z-D7D.
3. All assembled part numbers in catalog include standard (HW-F...) contacts.
4. Assembled units with spring-up terminals (HW-G...) can be ordered by removing an “F” from the
part number (Ex. HW1B-M1F11-R becomes HW1B-M111-R).
5. Units with exposed screw terminals (HW-C...) must be ordered as sub-components.
mPushbutton Color Code
Color
Code
Color
Amber
A*
Top
Green
Code
Code
Green
G*
Bottom
Red
6V AC/DC, LED
Q2
Red
R*
Top
White
12V AC/DC, LED
Q3
Blue
S*
Bottom
Black
24V AC/DC, LED
Q4
White
120V AC, LED
Q8
6V AC/DC, Incandescent
Q5*
12V AC/DC, Incandescent
Q6*
24V AC/DC, Incandescent
Q7*
GR
WB
Engraving
Code
No Engraving
Blank
I/ON
Top
O/OFF
Bottom
Contactors
Voltage
nEngraving Codes
1
W
*Only available in
LED illumination.
Terminal Blocks
Step-Down Transformer
(6V Secondary Lamp Voltage)
Code
120V AC, LED
H22
240V AC, LED
M42
480V AC, LED
T82
120V AC, Incandescent
H25*
240V AC, Incandescent
M45*
480V AC, Incandescent
T85*
Circuit Breakers
Voltage
*Only available for White Lens
Pilot Lamp.
800-262-IDEC (4332) • USA & Canada
591
Switches & Pilot Devices
H
Pilot Light
B: Without Center Pilot Light
L: With Center Pilot Light
Contactors
D
Part Number Structure
– L 21 F 20 20 H22 R – GR 1
Engraving Code
blank: No Engraving
1: Top: I/ON
Bottom: O/OFF
Pilot Lamp Color
Voltage Code
blank: without center pilot light
A: Amber*
G: Green*
Full Voltage*
Transformer*
Q2: 6V LED
H22: 120V AC LED R: Red*
*For additional voltage codes, please see previous page
S: Blue*
W: White
02: 2NC
20: 2NO
11: Momentary (Flush/Flush)
12: Momentary (Flush/Extended) Bottom Button
01: 1NC
02: 2NC
21: Interlock (Flush/Flush)
10: 1NO
20: 2NO
22: Interlock (Flush/Extended)
Y: Yellow*
blank: without center
pilot light
Pushbutton Color
GR: Top: Green
Bottom: Red
WB: Top: White
Bottom: Black
*Only available in LED illumination.
Dual Pushbutton Switches (Sub-assembled) Part Numbers
+
Mounting Adaptor
Lamp Circuit Components with Fingersafe Terminals
Style
Part
Number
Description
Lead Holder
Dummy Block
with Full Voltage
Adaptor
For use with HW-CBL
on all illuminated
pushbutton units. One
required for each deck
(pair) of contacts.
HW-LH3
For use with odd
number of contacts.
HW-DA1FB
+
Safety Lever
Lock
For use with even
number of contacts.
120VAC
240VAC
480VAC
Style
1NO
1NC
=
Completed Unit
Style
Contacts
Flush (bottom)
Flush (top)
HW-G01
HW-G01R
(late break)
Dummy
Block
Exposed
Screw
Terminal
HW-C01
HW-C01R
(late break)
TW-DB
Part Number
Non-illuminated
Illuminated (with
Pilot Light)
Style
HW-CB2C
HW-CBL
Extended (bottom)
Flush (top)
Flush (bottom)
Flush (top)
Extended (bottom)
Code
Top
Green
Bottom
Red
GR
HW9Z-LS
Anti-Rotation Ring
Appearance
Top
White
Bottom
Black
WB
12V AC/DC
LSTD-1k
24V AC/DC
LSTD-2k
120V AC
LSTD-H2k
240V AC
LSTD-M4k
6V AC/DC
IS-6
12V AC/DC
IS-12
24V AC/DC
IS-24
Illuminated
HW9Z-L7W
1. In place of k, specify the LED Color Code.
2. The LED contains a current-limiting resistor and reverse polarity protection diodes.
kLED Color Code
Use with notched panel cutout to prevent
unit rotation.
nEngraving Codes
Code
Part Number
LSTD-6k
HW9Z-B7B
HW9Z-RL
HW7D-*22m-n
Color
Voltage
6V AC/DC
Nonilluminated
Part Number
HW7D-*21m-n
mPushbutton Color Code
Color
Part Number
HW-C10
HW-C10R
(early make)
Lamps/Lens
1. Used to mount contact blocks to operator (first
pair only).
2. IDEC strongly recommends using the safety
lever lock (included) to prevent heavy vibration
or maintenance personnel from inadvertently
unlocking contacts.
Style
Instead of * insert:
B: Non-illuminated
L: Illuminated
1NC
HW-G10
Spring-Up
HW-G10R
Terminal
(early make)
HW7D-*11m-n
HW7D-*12m-n
1NO
Standard HW-F10
HW-F01
Fingersafe HW-F10R
HW-F01R
(IP20)
(early make) (late break)
Contact Block Mounting Adaptor
TW-F126B
TW-F246B
TW-F486B
Part Number
Flush (top)
Momentary
Lens
Safety Lever Lock
Button
Interlock
Contacts
TW-DA1FB
Operators
+
Contact Blocks
Exposed and spring up terminals also available.
Operator
Style
Full Voltage
Adaptor
592
+
LED
Contact Blocks
Style
Circuit Breakers
7
Incandescent
Relays & Sockets
Timers
01: 1NC
10: 1NO
Transformer Unit
(6V secondary
voltage)
Terminal Blocks
W
Contact Arrangement
Top Button
Button Arrangement
Signaling Lights
Switches & Pilot Devices
ø22mm - HW Series
Engraving
Code
No Engraving
Blank
I/ON
Top
O/OFF
Bottom
1
www.IDEC.com
Color
Code
Color
Code
Amber
A*
Blue
S*
Green
G*
White
W
Red
R*
Only for LED illumination.
Switches & Pilot Devices
ø22mm - HW Series
Contact Arrangement
Top Button Bottom Button Contact Code
1NO
1NO
1010
1NO
1NC
1001
1NC
1NO
0110
1NC
1NO
2NO
1NO-1NC
1NO
2NC
1NC
2NO
1NO-1NC
2NC
2NO
1NO
1NC
1NO-1NC
1NC
0111
0102
2010
2001
1110
1101
2
NO
1
NO
2
NC
1
NC
2
NO
1
NC
2
NC
1
NO
2
NO
3
Dummy
4
NO
1
NO
2
NO
3
Dummy
4
NC
1
NO
2
NC
3
Dummy
4
NC
1
NC
2
NO
3
Dummy
4
NO
1
NC
2
NO
3
Dummy
4
NC
1
NC
2
NC
3
Dummy
4
NC
1
NO
2
NO
3
NO
4
Dummy
1
NO
2
NC
3
NO
4
Dummy
1
NO
2
NO
3
NC
4
Dummy
1
NO
2
NO
3
NC
4
Dummy
Normal
Mounting Position 4
Mounting Position 2
Push
X
X
X
Mounting Position 3
Mounting Position 1
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Circuit Breakers
1NO-1NC
1NO
0120
NO
Push
Terminal Blocks
2NO
1002
1
Normal
Contactors
1NC
1011
Type
Timers
1NC
1020
Mounting Position
Bottom Button
Relays & Sockets
1NO
0101
Top Button
Signaling Lights
1NC
Contact Block Mounting Position Example
Contact Block
Switches & Pilot Devices
Contact Arrangement Chart
X
X
1. Transformers can have two or four contact blocks only.
2. Contact blocks 1 and 3 are actuated by the top button. Contact blocks 2 and 4 are actuated by the bottom button.
800-262-IDEC (4332) • USA & Canada
593
Switches & Pilot Devices
Signaling Lights
Switches & Pilot Devices
ø22mm - HW Series
Contact Arrangement
Top Button
2NC
2NC
1NC
Relays & Sockets
2NO
2NO
1NO-1NC
Timers
2NO
2NC
1NO-1NC
Contactors
1NO-1NC
1NO-1NC
2NC
2NO
1NO-1NC
2NC
2NO
2NC
1NO-1NC
2NC
Circuit Breakers
2NC
594
Bottom
Button
1NO
2NO
Terminal Blocks
Contact Block Mounting Position Example
Contact Arrangement Chart (con’t)
Contact
Code
0210
0201
2020
2011
2002
1120
1111
1102
0220
0211
0202
Contact Block
Mounting
Position
Top Button
Type
Normal
1
NC
X
2
NO
3
NC
4
Dummy
1
NC
2
NC
3
NC
4
Dummy
1
NO
2
NO
3
NO
4
NO
1
NO
2
NO
3
NO
4
NC
1
NO
2
NC
3
NO
4
NC
1
NO
2
NO
3
NC
4
NO
1
NO
2
NO
3
NC
4
NC
1
NO
2
NC
3
NC
4
NC
1
NC
2
NO
3
NC
4
NO
1
NC
2
NO
3
NC
4
NC
1
NC
2
NC
3
NC
4
NC
Bottom Button
Push
Normal
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
www.IDEC.com
Mounting Position 4
Mounting Position 2
Push
Mounting Position 3
Mounting Position 1
Switches & Pilot Devices
ø22mm - HW Series
Switches & Pilot Devices
Contactor Reset Button
Signaling Lights
Reset Buttons (Assembled)
j Button Color Code
Metal Bezel
(Blank)
HW1B-M1RS-jT
HW4B-M1RS-jT
Color
Code
Color
Code
Engraved “R”
HW1B-M1RS-jT-ENG-R
HW4B-M1RS-jT-ENG-R
Black
B
White
W
Green
G
Yellow
Y
Red
R
Gray
N
Blue
S
1. In place of j specify Button Color Code.
2. 130mm (5.1”) overall length.
3. 16mm flat base for easy alignment
Relays & Sockets
Plastic Bezel
Contactor Reset Button (Sub-assembled)
Rod
+
Operator
+
Button
=
Completed Unit
Timers
Rod
Button
Style
Part Number
Style
Part Number
HW1A-B1-j
Operator
Style
Plastic
Contactors
HW9Z-RS-TK2141
Metal
In place of j, specify the Button
Color Code from table.
j Button Color Code
HW4B-MO
Code
Color
Code
Black
B
White
W
Green
G
Yellow
Y
Red
R
Gray
N
Blue
S
Terminal Blocks
HW1B-MO
Color
Circuit Breakers
800-262-IDEC (4332) • USA & Canada
595
Switches & Pilot Devices
Switches & Pilot Devices
ø22mm - HW Series
Nameplates - HW Series
Engraving Plate
R14.9
ø22
1
45
1.6
0.9
2.7
12.1
30
27
HWAV–Yellow Plastic
ø22
1.9
1
Nameplate (blank
engraving plate
included)
HWAM-OB
HWAQ-OB
HWAS-OB
HWAV-O
HWAV5-0†
Nameplate (engraved)
HWAM-j
HWAQ-j
HWAS-j
HWAV-27*
HWAV5-27†
Additional Insert
(blank)
HWNP-O
HWNP-O
HWNP Dimensions
Additional Insert
(engraved)
HWNP-j
HWNP-j
12
Signaling Lights
1.5
HWAS–Black Plastic
14.5 14.9
2
29
2.7
14.5 14.9
R14.9
ø2
Relays & Sockets
Engraving Plate
12.1
30
29
27
HWAQ–Black Plastic
ø60mm
HWAM–Black Plastic
27
1. In place of j, insert either the standard legend code from table below or custom engraving delimited by “ “.
2. Standard engravings are available at no charge.
3. * HWAV-27 comes engraved “Emergency Stop” as shown in drawing.
4. † HWAV5-27 and HWAV5-0 for 60mm diameter E-Stops (80mm diameter nameplate).
Standard Legend Codes
Pushbuttons/Selector Switches
Selector Switches
Legend
Code
Legend
Code
Legend
Code
Legend
Code
Legend
Code
AUTO
CLOSE
DOWN
EMERG.STOP
FAST
FORWARD
HAND
HIGH
IN
INCH
JOG
LOW
LOWER
OFF
ON
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
OPEN
OUT
RAISE
RESET
REVERSE
RUN
SLOW
START
STOP
TEST
UP
I (Int’l On)
O (Int’l Off)
EMO
116
117
118
119
120
121
122
123
125
126
127
150
151
152
AUTO-MAN
CLOSE-OPEN
DOWN-UP
FAST-SLOW
FOR-REV
HAND-AUTO
HIGH-LOW
JOG-RUN
LEFT-RIGHT
LOWER-RAISE
MAN-AUTO
OFF-ON
ON-OFF
OPEN-CLOSE
RAISE-LOWER
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
REV-FOR
RUN-JOG
RUN-SAFE
SAFE-RUN
SLOW-FAST
START-STOP
STOP-START
UP-DOWN
OI (Int’l OFF ON)
216
217
218
219
220
221
222
223
250
AUTO-MAN-OFF
AUTO-OFF-MAN
CLOSE-OFF-OPEN
DOWN-OFF-SLOW
FAST-OFF-SLOW
FOR-OFF-REV
LEFT-OFF-RIGHT
LOWER-OFF-RAISE
OFF-MAN-AUTO
OFF-SLOW-FAST
OFF-1-2
OPEN-OFF-CLOSE
SLOW-OFF-FAST
SUMMER-OFF-WINTER
UP-OFF-DOWN
1-OFF-2
HAND-OFF-AUTO
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
1. To order engraved nameplates, add legend code to nameplate part number.
2. Character height based on the number of characters and size of nameplate. Standard character size is 3/16”.
3. Nameplates with standard legends are the same list price as blank nameplates.
4. Nameplates have built-in anti-rotation feature for use with notched panel cut-outs. Additional anti-rotation ring (HW9Z-RL) is not necessary.
Circuit Breakers
Terminal Blocks
Contactors
Timers
Pushbuttons
596
www.IDEC.com
22mm
Switches & Pilot Devices
ø22mm - HW Series
Switches & Pilot Devices
Nameplates Order Form — HW Series
Copy this order form and use it to specify Letter Height, Custom Engravings, Location of Engraving on Nameplate, and Quantity Desired.
To ensure engraving accuracy, fax it to your IDEC representative or Distributor.
IDEC Rep/Distributor Contact:
Name:
PO number (if known):
Telephone:
IDEC Rep/Distributor Phone:
Fax & Email:
IDEC Rep/Distributor Fax & Email:
Signaling Lights
Your Company:
HWAM Nameplate
Engraving
Location
Step 2.
Specify Quantity.
Enter the number of nameplates
desired in the box on the right.
7/64”
Letter
Size
11 characters maximum
(for 7/64” size letters)
1/8”
Letter
Size
9 characters maximum
(for 7/8” size letters)
Relays & Sockets
Step 1.
Choose Letter Size - 7/64” or 1/8”.
Check the box for the letter size you want.
Then write your lettering in box below the
check boxes. Note: 1/8” size letters cannot
exceed 9 characters.
Sample Letter Sizes
7/64” Letters: A B C D
Qty
1 2 3 4 5 6 7 8 9 10 11
1/8” Letters: A
BCD
Engraving
Location
Step 1.
Choose Letter Size - 7/64” or 1/8”.
Check the box for the letter size you want.
Then write your lettering in box below the
check boxes. Note: 1/8” size letters cannot
exceed 9 characters.
11 characters maximum
(for 7/64” size letters)
1/8”
Letter
Size
9 characters maximum
(for 7/8” size letters)
Sample Letter Sizes
Contactors
Step 2.
Specify Quantity.
Enter the number of nameplates
desired in the box on the right.
7/64”
Letter
Size
Timers
HWAQ Nameplate
7/64” Letters: A B C D
Qty
1 2 3 4 5 6 7 8 9 10 11
1/8” Letters: A
BCD
HWAS Nameplate
Qty
20 characters maximum
(for 3/32” size letters)
1/8”
Letter
Size
14 characters maximum
(for 7/8” size letters)
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
Step 3.
Specify Location.
Enter the location of engraving
Location
(A or B), in box on the right.
800-262-IDEC (4332) • USA & Canada
Circuit Breakers
Engraving Location B
Step 2.
Specify Quantity.
Enter the number of nameplates
desired in the box on the right.
3/32”
Letter
Size
Terminal Blocks
Engraving Location A
Step 1.
Choose Letter Size - 3/22” or 1/8”.
Check the box for the letter size you want.
Then write your lettering in box below the
check boxes. Note: 1/8” size letters cannot
exceed 9 characters.
Sample Letter Sizes
3/32” Letters: A B C D
1/8” Letters: A
BCD
597
Switches & Pilot Devices
Signaling Lights
Switches & Pilot Devices
ø22mm - HW Series
Switch Engraving Order Form – HW Series
Copy this order form and use it to specify Letter Height, Maximum Number of Lines and Text to be engraved.
To ensure engraving accuracy, fax it to your IDEC representative or Distributor.
Your Company:
Telephone:
Name:
Fax:
Address:
Email:
PO:
Part Number to be Engraved:
Please check one of the boxes below to indicate your choice of engraving options:
Relays & Sockets
ø29mm, ø40mm Mushroom Head
Engraving
# of Lines
Letter
Height
Max. Characters
Per Line
5/32
# of
Lines
5
Letter
Height
Area 2†
Max. Characters
Per Line
5/32
1
Timers
Engraving
Area 1
Round
Switch
Square
Switch
5
1
1/8
6
5/32
5
2
1/8
5
5/32
5
2
6
3
1/8
6
4
3/32
5
Contactors
1/8
1/8
6
3
1/8
5
4
3/32
5
1
Engraving
Area 2
1
Line 3:
Line 4:
For IDEC Internal Use Only:
Work Order #:
Sample Letter Sizes
5/32 Letters:
Line 2:
598
1/8 Letters:
Line 1:
Terminal Blocks
Engraving
Area 1
Letter
Height
Max. Characters
Per Line
5/32
5
1/8
5
5/32
7
1/8
7
1. Above mentioned specifications hold true for standard size pushbuttons (round and square).
2. †Engraving Area 2 can be engraved for 40mm mushroom Head non-Illuminated push button only.
3. Engraving is done on the button itself for non-Illuminated push buttons and on marking plate for illuminated push buttons and pilot lights.
4. Please enter text exactly how you want it engraved, take care to emphasize capital or small letters.
Enter text to be engraved:
Circuit Breakers
# of
Lines
www.IDEC.com
Switches & Pilot Devices
ø22mm - HW Series
Switches & Pilot Devices
Accessories
Item
Appearance
Part Number
Locking Ring Wrench
Metallic tool used to tighten the plastic locking ring when installing the HW
series in a panel
MW9Z-T1
Lamp/LED Removal
Tool
Rubber tool makes lamp/LED removal easier.
OR-55
Anti-Rotation Ring
Prevents rotation of switches in panel. (included with all assembled
switches except pilot lights)
for notched panel
cutout (standard)
HW9Z-RL
for round panel cutout
LW9Z-L
Black rubber plug fills unused 7/8” mounting holes in panel.
OB-31
Metallic Mounting
Hole Plug
For plugging unused 7/8” mounting holes in the panel. Tighten the attached
locking ring to a torque of 12 kfg-cm maximum
Degree of protection: IP66
LW9Z-BM
Barrier
To prevent contact between adjacent lead wires when buttons or switches
are tightly mounted close together.
HW-VL1
Used to cover and protect pushbuttons
Flush Pushbuttons
OC-31
Operating temperature: –50 to +60°C
Extended Pushbuttons
OC-32
Pushbutton Clear
Boot
Plastic hinged padlockable cover to protect pushbuttons or selector
switches. (Not intended for E-Stops)
HW9Z-KL1
Timers
Padlock Cover
Relays & Sockets
Rubber Mounting
Hole Plug
Signaling Lights
Description/Usage
Degree of protection: IP65
Tab #250 (6.35 x 0.8mm): Single tab
Mounting Adaptor
Used to mount round HW series (except Jumbo Mushroom, unibody, and square units) into a larger panel
cut-out. (includes both pieces)
TW-FA1
22 to 30mm
HW9Z-A30
22 to 25mm
HW9Z-A25
Contactors
Tab Terminal Adapter
HW9Z-LS
Reset Rod for
Contactors Overload
5” rod used with HW1B-M0.
HW9Z-RS-TK2141
Replacement Operator Washer
Provided with operator. Insert between bezel and locking ring.
HWM-WASHER
Replacement Locking
Ring
Plastic locking nut comes with all HW operators & assemblies.
Switch Cover
(Square)
Used only with round or square flush pushbuttons.
HW9Z-K1 (spring return)
HW9Z-K11 (maintained cover)
Replacement Keys
Pair of Keys (#231)
HW9Z-SKP
800-262-IDEC (4332) • USA & Canada
Standard (plastic)
HW9Z-LN
Optional (metal)
HW9Z-LNM
Circuit Breakers
Used to prevent contact mounting lever from moving due to heavy vibration
or panel maintenance.
Terminal Blocks
Replacement Safety
Lever Lock
599
Switches & Pilot Devices
Switches & Pilot Devices
ø22mm - HW Series
Item
Appearance
Replacement Lens
Description/Usage
Part Number
HW Illuminated Unibody Replacement Lens
HWLV-LENSR
Replacement Jumbo
Dome Lens
HW1A-P5j
j = (A, G, R, S, W, Y))
Relays & Sockets
Signaling Lights
Polycarbonate Replacement Lens
(If using yellow lens, use white LED.)
Replacement Jumbo
LED Diffusing Lens
HW9Z-PP5C
Replacement LED
Lamps for HW
Jumbo Dome
Replacement LED Lamp - applicable for jumbo pilot lights only
LSTDB-2j
j = (A, G, R, S, W)
Rubber Cover for
Dual Pushbuttons
Clear Silicon rubber cover
HW9Z-D7D
Barrier for Dual
Pushbuttons
Plastic barrier. Used when mounting the HW7 units on 30mm horizontal
centers, to prevent possible interconnections between adjoining terminals.
HW-VG1
Emergency stop nameplate sticker
HW9Z-EMO-NP-TK2120
E MO
EMO Sticker
Style
E-Stop Types
Applicable
Standards
HW9Z-KG1
40mm
Mushroom Head
SEMI S2-0703,
12.5.1 Compliant
HW9Z-KG2
40mm,
and 60mm
Mushroom Head
SEMI S2-0703, 12.5.1 &
SEMATECH Compliant
Part Numbers
Contactors
Timers
E-Stop Shrouds
Style
E-Stop Types
Applicable
Standards
HW9Z-KG3
40mm
Mushroom Head
SEMI S2 Compliant
(Approved by TUV)
HW9Z-KG4
40mm
Mushroom Head
SEMI S2 Compliant
(Approved by TUV)
& SEMATECH
Part Numbers
Contact Assemblies
Standard Contact Assemblies
Style
Contacts
Part Number
Standard Fingersafe Contacts
1NO
1NC
1NO/1NC
2NO
2NC
2NO/2NC
HW-CBF10
HW-CBF01
HW-CBF11
HW-CBF20
HW-CBF02
HW-CBF22
Spring Up Terminal Contacts
1NO
1NC
1NO/1NC
2NO
2NC
2NO/2NC
HW-CB10
HW-CB01
HW-CB11
HW-CB20
HW-CB02
HW-CB22
Circuit Breakers
Terminal Blocks
For use with Non-Illuminated Pushbuttons & E-Stops
600
Full Voltage Contact Assemblies
For use with Illuminated Pushbuttons.
Style
Order lamp separately.
Gold contact option is available for spring-up terminals. Add suffix “MAU” to end
of part number. For example, HW-CB20 becomes HW-CB20-MAU.
www.IDEC.com
Contacts
Part Number
1NO
2NO
1NO/1NC
1NC
2NC
HW-FL10Q0
HW-FL20Q0
HW-FL11Q0
HW-FL01Q0
HW-FL02Q0
Switches & Pilot Devices
ø22mm - HW Series
Switches & Pilot Devices
Transfomer Contact Assemblies
For use with Illuminated Pushbuttons.
Style
120V AC
with LED
1NO
2NO
1NC
1NO/1NC
HW-FL10H2-k
HW-FL20H2-k
HW-FL01H2-k
HW-FL11H2-k
240V AC
with LED
1NO
2NO
1NC
1NO/1NC
HW-FL10M4-k
HW-FL20M4-k
HW-FL01M4-k
HW-FL11M4-k
480V AC
with LED
1NO
2NO
1NC
1NO/1NC
HW-FL10T8-k
HW-FL20T8-k
HW-FL01T8-k
HW-FL11T8-k
120V AC with
Incandescent
1NO
2NO
1NC
1NO/1NC
HW-FL10H2
HW-FL20H2
HW-FL01H2
HW-FL11H2
240V AC with
Incandescent
1NO
2NO
1NC
1NO/1NC
HW-FL10M4
HW-FL20M4
HW-FL01M4
HW-FL11M4
Relays & Sockets
Part Number
Signaling Lights
Contacts
1. In place of k, specify the LED Color Code.
k = A, G, R, S, or W
2. 6V LED or incandescent lamp included.
Dimensions (mm)
Non-Illuminated Pushbuttons
Extended (HW1B-M2, -A2)
ø29mm Mushroom (HW1B-M3 -A3)
M3.5 Terminal
Screw
M3.5 Terminal
Screw
M3.5 Terminal
Screw
Locking Ring
LO
LO
Locking Ring
CK
Panel Thickness
0.8 to 6
CK
41.4
ø29
41.4
ø29
ø23.6
41.4
ø29
LO
25
25
CK
Panel Thickness
0.8 to 6
25
Locking Ring
Panel Thickness
0.8 to 6
Timers
Flush (HW1B-M1, -A1)
3.6
ø2
13
13
29.4
50.2 (1 or 2 blocks)
ø40mm Mushroom (HW1B-M4, -A4)
LO
CK
ø60mm Mushroom (HW1B-M5)
Square Flush (HW2B-M1, -A1)
M3.5 Terminal
Screw
Locking Ring
M3.5 Terminal
Screw
Panel Thickness 0.8 to 6
Locking Ring
Panel Thickness
0.8 to 6
CK
29.6
ø60
41.4
ø40
50.2 (1 or 2 blocks)
29.4
23.2
LO
70.2 (4 blocks)
50.2 (1 or 2 blocks)
13
70.2 (4 blocks)
15
30
Terminal Blocks
13
50.2 (1 or 2 blocks)
29.4
23.2
25
Locking Ring
Panel Thickness
0.8 to 6
70.2 (4 blocks)
25
M3.5 Terminal
Screw
13
50.2 (1 or 2 blocks)
Contactors
70.2 (4 blocks)
29.4
19
41.4
50.2 (1 or 2 blocks)
70.2 (4 blocks)
24.8
29.4
70.2 (4 blocks)
Square Extended (HW2B-M2, -A2)
M3.5 Terminal
Screw
Terminal Wiring
Arrows indicate access directions for wiring
Panel Thickness
0.8 to 6
LO
CK
Circuit Breakers
13
50.2 (1 or 2 blocks)
70.2 (4 blocks)
19
29.4
41.4
24.8
29.6
25
Locking Ring
Contact Block (Bottom View)
1 contact block
2 contact blocks
4 contact blocks
800-262-IDEC (4332) • USA & Canada
601
Switches & Pilot Devices
Operators
Dimensions (mm)
Flush (Round & Square)
Extended
Round
Panel Thickness
0.8 to 6
CK
LO
CK
.6
29.4
29.4
18.5
24.8
29.4
Extended with Full Shroud
ø40mm Mushroom
LO
LO
CK
41.4
3.6
ø40
41.4
25
25
CK
ø29.5
Extended
3
ø2
13
ø2
13
41.4
41.4
29.6
41.4
25
ø23.5
25
CK
3.6
Signaling Lights
LO
Square
LO
25
Switches & Pilot Devices
ø22mm - HW Series
Relays & Sockets
ø2
29.4
18.5
13
29.4
23.2
Emergency Stop Pushbuttons
Dimensions (mm)
ø29mm Head Pushlock Turn Reset (HW1B-V3)
Panel Thickness 0.8 to 6
Gasket
Terminal Screw M3.5
LOC
Locking Ring
ø29
50.2 (1 or 2 blocks)
70.2 (4 blocks)
13
29.4
32
ø40mm Head Pushlock Turn Reset (HW1B-V4)
ø40mm Head EMO Pushlock Turn Reset (HW1B-V4)
LOC
LOC
K
Locking Ring
Lock Lever
0
ø4
ø40
41.4
20
25
26.5
K
13
29.4
13
32
32
ø40mm Head Pushlock Key Reset (HW1B-X4)
ø60mm Head Pushlock Turn Reset (HW1B-V5)
LOC
K
41.4
ø40
Circuit Breakers
ø60
25
Terminal Blocks
50.2 (1 or 2 blocks)
70.2 (4 blocks)
13
29.4
32
49.4
602
15
34.5
www.IDEC.com
29.4
41.4
2 contact blocks
4 contact blocks
25
1 contact block
Contactors
41.4
25
Timers
K
Switches & Pilot Devices
Switches & Pilot Devices
ø40mm Head Push-Pull (HW1B-Y2)
ø22mm - HW Series
ø40mm Head Unibody Pushlock Turn Reset (HW1B-BV4)
LO
Panel Thickness 0.8 to 6
CK
Gasket
M3.5 Terminal Screw
ø40
ø40
41.4
25
Locking Ring
13
29.4
TOP Marking
Terminal Cover
11.5
46
Signaling Lights
25.5
14
32
48
Illuminated E-Stop Pushbuttons (HW1E-LV4)
Mounting Hole
Panel Thickness 0.8 to 6
R0.8 max.
Gasket
.3
+0.4
0
ø40
24.1
TOP Marking
M3.5 Terminal Screw
Lamp Terminal
11.5
14
32
61
Terminal Cover
63
The minimum mounting centers shown below are applicable to E-Stop switches with
one layer of contact blocks (two contact
blocks). When two layers of contact blocks
are mounted, determine the minimum
mounting centers for ease of wiring.
Unit
Vertical Spacing
Horizontal Spacing
HW1B-V3
HW1B-V4
HW1B-X4
HW1B-Y2
50 mm
50 mm
HW1B-V5
60 mm
60 mm
Relays & Sockets
ø22
Locking Ring
+0.2
0
3.2
+0.4
0
M3.5 Terminal Screw
HW1E-BV4
Side
HW1E-LV4
Timers
Terminal Arrangement (Bottom View)
TOP
X1
.2 (NC)
.3 (NO)
.1 (NC)
.4 (NO)
LAMP
.2 (NC)
.3 (NO)
.1 (NC)
.4 (NO)
X2
(1NO-1NC)
(1NO-1NC)
Contactors
Emergency Stop Stations
59.5
Operator
Dimension A (mm)
Pushlock Turn Reset
32
Pushlock Key Reset
32 (Key inserted: 49.4)
Push Pull
25.5
Mounting Hole Layout
4-M4 Tapped Holes for Rear Mounting
(Depth: 10 mm)
2-Front Mounting Holes
ø14 Knockout
21
76
A
Terminal Blocks
76
Dimensions (mm)
21
41
HW1B-V4R
Box Cover Mouting Screws
Box Cover
Box Base
2-
ø4
.6
Circuit Breakers
15.5
62
800-262-IDEC (4332) • USA & Canada
603
Switches & Pilot Devices
Switches & Pilot Devices
ø22mm - HW Series
Pilot Lights
Dimensions (mm)
Full Voltage
Panel Thickness 0.8 to 6
Flush
Gasket
Locking Ring
M3.5 Terminal Screw
Dome
Square Flush
Round/Dome
9
ø2
X2
X1
Transformer
X1
X2
Round/Dome
9
Square Flush
Close mounting on 30mm centers
Degree of protection: IP65
30 min.
Dome
+0.4
0
ø2
72.1
17.5
7
29.6
30 min.
DC-DC Converter
Flush
M3.5 Terminal Screw
Dome
Round/Dome
9
Square Flush
ø2
When mounting transformer or DC-DC converter type
units on 30mm centers vertically and horizontally, keep
the ambient temperature below 40ºC.
24
X1
X2
76.2
29.6
29.6
17.5
7
Jumbo Dome Pilot Lights
Base BA9S/13
Illumination Color
Incandescent Lamp LSB
Base BA9S/13
Mounting Hole Layout
R0.8 max.
ø22.3
+0.4
0
3.2
+0.2
0
+0.4
0
Light blue:
LSTDB
ø10.6
M3.5 Terminal Screw
LED Lamp LSTDB
27 2
24.1
6
ø6
1
Panel Thickness 1 to 5
ø10
Relays & Sockets
.3
ø22
Mounting Hole Layout
Flush
M3.5 Terminal Screw
29.6
Timers
29.6
17.5
7
24
Signaling Lights
0.5
44.7
85
20.4
Locking Ring
Rubber Gasket
50.5
Contactors
0.5
34.4
85
Illuminated Pushbuttons
Full Voltage Models
1 Contact Block
2 Contact Blocks
Terminal Blocks
M3.5 Terminal Screw
Contact Block
Locking Ring
3 Contact Blocks
Full Voltage Adapter
Full Voltage Adapter
Panel
Thickness
0.8 to 6
M3.5 Terminal Screw
Contact Block
Locking Ring
Full Voltage Adapter
M3.5 Terminal Screw
Contact Block
Panel
Thickness
0.8 to 6
Locking Ring
X1
Circuit Breakers
X2
1 contact block
604
50.2 (1 block)
2 contact blocks
65.8 (2 blocks)
www.IDEC.com
3 contact blocks
70.2 (3 blocks)
Panel
Thickness
0.8 to 6
Switches & Pilot Devices
ø22mm - HW Series
Dimensions (mm)
4 Contact Blocks
Terminal Wiring
Arrows indicate access directions for wiring.
Full Voltage Adapter
Contact Block
Full Voltage Adaptor
M3.5 Terminal Screw
Contact Block
Locking Ring
Switches & Pilot Devices
Illuminated Pushbuttons con’t
Transformer
Panel
Thickness
0.8 to 6
X1
X2
Signaling Lights
85.8 (4 contacts)
4 contact blocks
Transformer Models
DC-DC Converter Models
Safety Lever Lock
Locking Ring
3
X1
4
X2
Relays & Sockets
X1
X2
M3.5 Terminal Screws
89.7 (2 blocks)
109.5 (4 blocks)
M3.5 Terminal Screw
89.5 (2 blocks)
109.5 (4 blocks)
Non-Illuminated Selector & Key Switches
Dimensions (mm)
Knob Operator
Terminal Wiring
M3.5 Terminal
Screw
Arrows indicate access directions
for wiring.
Panel Thickness 0.8 to 6
Gasket
CK
9
Contact Block
Full Voltage Adaptor
1 contact block
48.5 (1 or 2 blocks)
7
29.4
68.5 (3 or 4 blocks)
21
Key Operator
Contactors
2 contact blocks
4 contact blocks
41.4
ø28.8
25
ø2
Timers
LO
Locking Ring
Tranformer
LOC
K
9.4
25
ø2
17
41.4
X1
X2
Terminal Blocks
13
29.4
30.5
Illuminated Selector Switches
LO
CK
Transformer Model
LOC
K
9
41.4
25
X1
7
X2
M.3.5 Terminal
Screw
79.5 (2 blocks)
99.5 (4 blocks)
Circuit Breakers
69.4 (2 blocks)
41.4
ø2
89.4 (4 blocks)
9
ø2
25
4
M3.5 Terminal Screw
3
Full Voltage Model
7
21
29.4
29.4
21
800-262-IDEC (4332) • USA & Canada
605
Switches & Pilot Devices
Dual Pushbutton
Dimensions (mm)
Without Pilot Light
Mounting Hole Layout
R0.8 max.
ø22
*3.2
+0.
4
0
+0.2
0
24.1
.3
+0.4
0
HW
Switches & Pilot Devices
ø22mm - HW Series
49.4 (2 contacts)
Without Button
Markings
Locking Ring
With Button Markings
(I/ON and O/OFF)
30
54.8
54.8
ON
OFF
Rubber Gasket
Relays & Sockets
55 **
Panel Thickness 0.8 to 6
Safety Lever Lock
41.4
Signaling Lights
69.4 (3 or 4 contacts)
0.5
29.8
14.5
20
29.8
With Pilot Light
Full Voltage
The depth of a 3-contact model depends on the combination of
contact blocks at top and bottom pushbuttons.
Full Voltage Adapter
HW
(Bottom Button)
Timers
(Top Button)
Top Button
1 contact block
2 contact blocks
Bottom Button
2 contact blocks
1 contact block
Depth
89.4 mm
69.4 mm
-The 3.2 mm recess is for preventing rotation and is not necessary when a nameplate
or anti-rotation ring is not used.
-When using the safety lever lock, determine the vertical spacing in consideration
of convenience for installing and removing
the safety lever lock.
-Recommended vertical spacing: 100 mm
-The minimum mounting centers are
applicable to switches with one layer of
contact blocks (two contact blocks). When
two layers of contact blocks are mounted,
determine the minimum mounting centers
for ease of wiring.
69.4 (2 contacts), 89.4 (4 contacts)
(Note)
Transfomer (240V minimum)
Transformer (480V)
Transformer, DC-DC Converter
Transformer
Contactors
HW
HW
89.5 (2 contacts), 109.5 (4 contacts)
Locking Ring
Panel Thickness 0.8 to 6
LO
Monolever
Dimensions (mm)
ø3
4
M3.5 Terminal
Screw
.2
79.5 (2 contacts), 99.5 (4 contacts)
8
Circuit Breakers
24ϒ
36 max.
45.5
606
29.4
72
24ϒ
49.4 (2 blocks)
69.4 (4 blocks)
36 max.
Terminal Blocks
41.4
25
CK
www.IDEC.com
Switches & Pilot Devices
ø22mm - HW Series
Switches & Pilot Devices
Accessory Dimensions
LW9Z-BM
OB-31
Metallic Mounting Hole Plug
OR-55
Anti-Rotation Ring
Lamp/LED Removal Tool
TOP
ø14
1.5
3.5
3.5
ø25
HW-VG1
Dual Pushbutton Rubber Cover
Dual Pushbutton Barrier
MW9Z-T1
22.5
Barrier
28
ø
110
58
45
45
33
HW-VL1
Locking Ring Wrench
Signaling Lights
HW9Z-D7D
59
ø11.6
ø29
ø22
12
Gasket
Locking Ring
HW9Z-RL
ø29
3
ø25.8
Rubber Mounting Hole Plug
1.5
20
1.5
HWLS-TK1971
Padlock Cover
Relays & Sockets
HW9Z-KL1
20
Safety Lever Lock
Panel Thickness
0.8 to 3.2
Safety Lever Lock
Screwdriver
Remove
Lock Lever
Safety Lever
Lock
CK
LO
26.5
70
30
93
6.5
R6
Operator
Install
82.5
24
ø2
2.2
0
ø5 .4)
44
:ø
(ID
Waterproof Rubber
Gasket 0.5t
Contact Block
Mounting Adapter
HW9Z-KG1
Timers
29.5
30
Key Hole ø8
Panel
HW9Z-KG2
38
22
36.5
80
32
ø22
ø90
Gasket
TOP Marking
TOP Marking
Contactors
ø76.1
2.2
ø2
64
48
Locking Ring
TOP Marking
TOP Marking
Locking Ring
Operator
Panel Thickness: 1.2 to 4
Operator
Terminal Blocks
Panel Thickness: 1.2 to 4
HW9Z-KG3
HW9Z-KG4
LSTD
35
25
ø2
35
25
2
ø9.5
800-262-IDEC (4332) • USA & Canada
20.4
50
Circuit Breakers
42
ø10.6
ø90
67
ø75
ø74
52
ø66
ø22
607
Switches & Pilot Devices
Switches & Pilot Devices
ø22mm - HW Series
Specification Charts
Signaling Lights
Conforming to IED 947-5-1 Appendix C.
Utilization categories AC-15 and DC-13.
Operation rate: 1,800 op. hour
Load factor:
Inductive 0.4 ± 0.05
Resistive 0.9 ± 0.05
Operator Truth Tables
2 Position Selector Switches
Timers
Relays & Sockets
Contact
HW-F10
(NO)
HW1S-2T
HW1K-2*
HW1F-2
HW-F01
(NC)
HW-F10R
(NO-EM)
HW-F01R
(NC-LB)
Operator
Position
Left
Right
L
O
X
R
O
X
L
X
O
R
X
O
L
O
X
R
O
X
L
X
O
R
X
O
Contact
HW1S-3JT
HW1K-3J*
HW-F10
(NO)
HW1S-3T
HW1K-3*
HW1F-3
HW-F01
(NC)
HW-F10R
(NO-EM)
HW-F01R
(NC-LB)
Mounting
Position
Operator Position
Left
Center
Right
HW-F10
(NO)
L
X
O
O
R
O
O
X
HW-F01
(NC)
L
O
X
O
R
O
X
O
HW-FC10R
(NO-EM)
L
X
O
X
R
X
O
X
HW-F01R
(NC-LB)
L
O
X
X
R
X
X
O
4 Position Selector Switches
3 Position Selector Switches
Contact
Contactors
Mounting
Position
3 Position Selector Switches con’t
Contact
Operator Position
Mounting
Position
Left
L
X
O
O
R
O
O
X
L
O
X
X
R
X
X
O
L
X
O
O
R
O
O
X
L
O
X
X
R
X
X
O
Center Right
HW1S-4T
Mounting
Position
Operator Position
1
2
3
4
HW-F10
(NO)
L
X
O
O
O
R
O
O
O
X
HW-F01
(NC)
L
O
O
X
O
R
O
X
O
O
HW-F10R
(NO-EM)
L
X
X
O
X
R
X
O
X
X
HW-F01R
(NC-LB)
L
O
X
X
X
R
X
X
X
O
1
2
Terminal Blocks
5 Position Selector Switches
Contact
HW-F10
(NO)
Circuit Breakers
HW1S-3ST
HW1K-3S*
HW-F01
(NC)
HW-F10R
(NO-EM)
HW-F01R
(NC-LB)
Operator Position
Mounting
Position
Left
Center
Right
L
X
O
O
R
O
O
X
L
O
O
X
R
X
O
O
L
X
X
O
R
O
X
X
L
O
X
X
R
X
X
O
Contact
HW-F10
(NO)
HW1S-5T
HW-F10R
(NO-EM)
HW-F01R
(NC-LB)
1. Mounting position indicates which side of operator each contact should be mounted (as
viewed from the front of the panel).
2. *For key removable code see page 579.
608
HW-F01
(NC)
Mounting
Position
Operator Position
4
5
O
L
X
O
O
O
R
O
O
O
O
X
L
O
O
O
X
O
R
O
X
O
O
O
L
X
X
X
O
X
R
X
O
X
X
X
L
O
X
X
X
X
R
X
X
X
X
O
3. HW1S-3T is identified by white plungers on the operator.
4. HW1S-3ST is identified by red plungers on the operator.
5. HW1S-3JT is identified by black plungers on the operator.
www.IDEC.com
3
Switches & Pilot Devices
ø22mm - HW Series
Turn off power to HW series control units before starting installation, removal,
wiring, maintenance, and inspection of the products. Failure to turn power off
may cause electrical shocks or fire hazard.
For wiring, use wires of a proper size to meet voltage and current requirements.
Tighten the M3.5 terminal screws to a tightening torque of 1.0 to 1.3 N·m.
Failure to tighten terminal screws may cause overheating and fire.
To avoid the possibility of burning yourself, use the lamp holder tool when
replacing lamps.
Switches & Pilot Devices
HW Safety Precautions
HW General Instructions
Remove the contact block assembly from the operator (for transformer type pilot
lights, remove the transformer from the illumination unit). Remove the locking
ring from the operator. Insert the operator into the panel cut-out from the front,
tighten the locking ring from the back, then install the contact block assembly to
the operator.
Removing and Installing the Contact Block Assembly
2. To reinstall, place the TOP markings on the operator and the contact block
mounting adapter in the same direction, and insert the operator into the
contact block mounting adapter. Then turn the locking lever in the opposite
direction.
IDEC strongly recommends using the safety lever lock (HW9Z-LS, yellow) to
prevent heavy vibration or maintenance personnel from unlocking the contact
assembly.
1. HW series can be mounted vertically with a minimum spacing of 55 mm
but spacing should be determined to ensure easy operation (recommended
minimum spacing: 100 mm).
2. Mount the control unit onto the panel, lock the lever, and push in the safety
lever lock to install.
3. When the spacing is narrower than the recommended value, with the lever unlocked, mount the safety lever lock and insert the contact unit to the operator.
Then, lock the lever and strongly push in the safety lever lock to install.
Relays & Sockets
1. To remove the operator from the contact block, turn the locking lever in the
direction of the arrow shown below. The operator can now be removed.
Safety Lever Lock
Signaling Lights
Panel Mounting
4. To remove the safety lever lock, insert a flat screwdriver into the safety lever
and push upwards.
Remove
Safety Lever
Lock
CK
LO
26.5
Lock Lever
Timers
Operator
Install
Safety Lever Lock
Screwdriver
Contact Block
Mounting Adapter
Notes for Panel Mounting
Panel
Contactors
1. When mounting the operator onto a panel, use the optional locking ring
wrench (MW9Z-T1) to tighten the locking ring. Tightening torque must not
exceed 2.0 N·m. Do not use pliers. Excessive tightening will damage the
locking ring.
2. For the contact blocks and transformers housing LED and incandescent lamps,
make sure not to press the lamps too hard, otherwise the lamp socket may be
damaged.
Terminal Blocks
Dual Pushbutton Instructions
Replacement of Lens
Removing
Remove the lens by inserting a screwdriver into the recess of the lens through
the bezel.
Circuit Breakers
Installing
Install the lens in the recess between the buttons by pressing against the bezel.
800-262-IDEC (4332) • USA & Canada
609
Switches & Pilot Devices
Dual Pushbuttons Instructions con’t
Replacement of Lamps
Tightening Torque for Terminal Screws
Lamps can be replaced by using the lamp holder tool (OR-55) from the front of
the panel, or by removing the contact block assembly from the operator unit.
When using full voltage type LED illuminated units, provide protection against
electrical noise, if necessary.
Removal
Applicable Wiring
The applicable wire size is 2 mm2 maximum. (solid wire ø1.6mm2 maximum) One
or two wires can be connected.
1. To remove, slip the lamp
holder tool onto the lamp
head lightly. Then push
slightly, and turn the lamp
holder tool counterclockwise.
Applicable Crimping Terminal
7.9 max.
ø3.6 min.
Installation
1. To install, insert the lamp
head into the lamp holder
tool, and hold the lamp as
shown in the figure below.
4 max.
Lamp
Solid Wire
Timers
Lamp Base
8 max.
Note: When connecting wires to contact blocks or transformers in the direction
shown below, keep the insulation stripping length 6.6 mm at the maximum.
About Pushbutton Switches
Do not attempt to remove
using a flat screwdriver or pincers, otherwise the pushbuttons may be damaged.
5.5 min.
Be sure to use an insulation tube or cover on the crimping part of the crimping
terminal to prevent electrical shocks.
Lamp Holder Tool
Do not attempt
to remove the
pushbuttons!
The pushbuttons cannot be
removed or replaced!
Contactors
Installation of LED Illuminated Units
Removing the Lamps from the Front of the Panel
2. Place the pins on the lamp
base to the grooves in the
lamp socket. Insert the lamp
and turn it clockwise.
X1
Pushbuttons
X2
Inside
X1
X2
Inside
Installing the Rubber Cover
Narrow Mounting
When mounting the units closely in a horizontal row on 30mm centers, use optional barriers to prevent interconnection between adjoining terminals. The barriers can be attached simply by pressing them onto the sides of contact blocks.
30
When using the HW7D pushbuttons in places where the pushbuttons are
subjected to water splash or an excessive amount of dust, make sure to use the
HW9Z-D7D rubber boot (IP65) which is ordered separately.
Notes for Installing the Rubber Cover
30
Remove the gasket from the operator, and install the rubber boot on the operator.
Pull out the seals of the rubber boot and place them around the operator sleeve
as shown. Make sure that the seals are not twisted or tucked inside and that
the gasket does not remain, otherwise the normal waterproof and dustproof
characteristics are not ensured.
Terminal Blocks
Circuit Breakers
Tighten the M3.5 terminal screws to a torque of 1.0 to 1.3 N·m.
ø1.6 max.
Relays & Sockets
Signaling Lights
Switches & Pilot Devices
ø22mm - HW Series
1. Remove the gasket.
Barrier
When mounting transformer type illuminated
units closely in a horizontal row on 30-mm
centers, insert solid wires or stranded wires
into inside of the terminal screw on the
transformer (see figure on the right) to prevent
short circuit between adjoining terminals.
Seals
Install
X1
X2
Inside
X1
Remove
X2
Inside
Gasket
610
2. Install the rubber boot
on the pushbuttons.
www.IDEC.com
Seals
3. Rubber boot is
installed.